Search Results

Search found 3312 results on 133 pages for 'freebsd ports'.

Page 94/133 | < Previous Page | 90 91 92 93 94 95 96 97 98 99 100 101  | Next Page >

  • setting library include paths in c++

    - by Drew
    Hi all, I just installed gd2 using mac ports (sudo install gd2), which installed libraries in the following places: /opt/local/include/gd.h /opt/local/lib/libgd.dylib (link) /opt/local/lib/libgd.la /opt/local/lib/libgd.a So when I create my c++ app I add '#include "gd.h"', which throws: main.cpp:4:16: error: gd.h: No such file or directory If I set gd.h as an absolute path (as above)(not a solution, but was curious), I am thrown: g++ -L/opt/local/include -L/opt/local/lib main.o Heatmap_Map.o Heatmap_Point.o -o heatmap Undefined symbols: "_gdImagePng", referenced from: _main in main.o "_gdImageLine", referenced from: _main in main.o "_gdImageColorAllocate", referenced from: _main in main.o _main in main.o "_gdImageDestroy", referenced from: _main in main.o "_gdImageCreate", referenced from: _main in main.o "_gdImageJpeg", referenced from: _main in main.o ld: symbol(s) not found So, I understand this means that ld can not find the libraries it needs (hence trying to give it hints with the "-L" values). So after giving g++ the -L hints and the absolute path in #include, I can get it to work, but I don't think I have to do this, how can I make g++/ld search int eh right places for the libraries? Drew J. Sonne.

    Read the article

  • dynamically horizontal scalable key value store

    - by Zubair
    Hi, Is there a key value store that will give me the following: Allow me to simply add and remove nodes and will redstribute the data automatically Allow me to remove nodes and still have 2 extra data nodes to provide redundancy Allow me to store text or images up to 1GB in size Can store small size data up to 100TB of data Fast (so will allow queries to be performed on top of it) Make all this transparent to the client Works on Ubuntu/FreeBSD or Mac Free or open source I basically want something I can use a "single", and not have to worry about having memcached, a db, and several storage components so yes, I do want a database "silver bullet" you could say. Thanks Zubair Answers so far: MogileFS on top of BackBlaze - As far as I can see this is just a filesystem, and after some research it only seems to be appropriate for large image files Tokyo Tyrant - Needs lightcloud. This doesn't auto scale as you add new nodes. I did look into this and it seems it is very fast for queries which fit onto a single node though Riak - This is one I am looking into myself, but I don't have any results yet Amazon S3 - Is anyone using this as their sole persistance layer in production? From what I have seen it seems to be used for storage of images as complex queries are too expensive @shaman suggested Cassandra - definitely one I am looking into So far it seems that there is no database or key value store that fulfills the criteria I mentioned, not even after offering a bounty of 100 points did the question get answered!

    Read the article

  • Sending SMS with GSM phone\modem using Objective C

    - by user291182
    Hi Im new with Objective C but a veteran of C# & VB.Net. Is there an available API or functionality in cocoa where i can communicate with my GSM Phone to listen to any incoming SMS messages and be able to send messages myself. I'm trying to build an application for OSX SnowLeopard that can do this. Under the windows platform there are available API's that i can use to do this job for me. I just need hook up my mobile phone into my PC, configure the API to communicate with the phone thru one of the available COM Ports used by the device. Your help is very much appreciated. Thanks [email protected]

    Read the article

  • MultiCast Messages to multiple clients on the same machine

    - by Christopher Chase
    Im trying to write a server/service that broadcasts a message on the lan ever second or so, Kind of like a service discovery. The message needs to be received by multiple client programs that could be on the same machine or different machines. But there could be more than one program on each machine running at the same time. Im using delphi7, with indy 9.0.18 where im stuck is if i should be using UDP or IP MultiCast or if its even possible... Ive managed to get it to work with IP Multi Cast with one client per machine, but even after many trys with different bindings.. max/min ports etc, i cant seem to find a solution.

    Read the article

  • [Ubuntu] How can i log-in to Ubuntu using USB-serial console (rs232) ?

    - by marc
    Welcome, How can enable remote terminal login into Ubuntu 9.10 using usb-serial terminal ? I got created device ttyUSB0 and i want allow to log-in using hyper-terminal. I found some resources but they are related to real! hardware rs232 ports, i can't find any information about USB converter. Right now i have established connection between that usb-serial port and my laptop (i can send text writing to port cp sometext.txt /dev/ttyUSB0 and read using hyperterminal). Any idea ? Regards

    Read the article

  • TeX on iPad compatible with Apple's policy?

    - by Yuji
    Hi, As a nerd, I think it would be nice to have a TeX editor on the iPad. But TeX is a Turing-complete language, and it is arguably a general-purpose compiler/interpreter. Does that make it unacceptable to the App Store? Furthermore, if somebody ports TeX compiler to javascript and runs inside WebKit, does it make acceptable to the App Store? FYI, here's the section of the developer's agreement: 3.3.2 An Application may not itself install or launch other executable code by any means, including without limitation through the use of a plug-in architecture, calling other frameworks, other APIs or otherwise. No interpreted code may be downloaded and used in an Application except for code that is interpreted and run by Apple's Published APIs and builtin interpreter(s).

    Read the article

  • What operating systems available for an 8-bit microprocessor?

    - by Benoit
    It does not need to be a full fledged OS, but at least have multitasking capabilities (i.e. a scheduler). Please mention what processor architecture it works on. This is a survey, so exact capabilities are not really important. Think of this as being a place to look at for possibilities when your next 8-bit embedded project comes up... I realize that most 8-bit micro do not require an OS, but just as a counter-example, Rabbit Semiconductor offers the RCM3710 processor module with 4 serial ports, a 10-BaseT ethernet port, 512K RAM and 512K Flash. All that for $39. All based around an 8-bit Z80 core. 8-bit does NOT necessarily mean extreme resource constraint.

    Read the article

  • PyGTK/GIO: monitor directory for changes recursively

    - by detly
    Take the following demo code (from the GIO answer to this question), which uses a GIO FileMonitor to monitor a directory for changes: import gio def directory_changed(monitor, file1, file2, evt_type): print "Changed:", file1, file2, evt_type gfile = gio.File(".") monitor = gfile.monitor_directory(gio.FILE_MONITOR_NONE, None) monitor.connect("changed", directory_changed) import glib ml = glib.MainLoop() ml.run() After running this code, I can then create and modify child nodes and be notified of the changes. However, this only works for immediate children (I am aware that the docs don't say otherwise). The last of the following shell commands will not result in a notification: touch one mkdir two touch two/three Is there an easy way to make it recursive? I'd rather not manually code something that looks for directory creation and adds a monitor, removing them on deletion, etc. The intended use is for a VCS file browser extension, to be able to cache the statuses of files in a working copy and update them individually on changes. So there might by anywhere from tens to thousands (or more) directories to monitor. I'd like to just find the root of the working copy and add the file monitor there. I know about pyinotify, but I'm avoiding it so that this works under non-Linux kernels such as FreeBSD or... others. As far as I'm aware, the GIO FileMonitor uses inotify underneath where available, and I can understand not emphasising the implementation to maintain some degree of abstraction, but it suggested to me that it should be possible. (In case it matters, I originally posted this on the PyGTK mailing list.)

    Read the article

  • C# thread with multiple parameters

    - by Lucas B
    Does anyone know how to pass multiple parameters into a Thread.Start routine? I thought of extending the class, but the C# Thread class is sealed. Here is what I think the code would look like: ... Thread standardTCPServerThread = new Thread(startSocketServerAsThread); standardServerThread.Start( orchestrator, initializeMemberBalance, arg, 60000); ... } static void startSocketServerAsThread(ServiceOrchestrator orchestrator, List<int> memberBalances, string arg, int port) { startSocketServer(orchestrator, memberBalances, arg, port); } Thank you in advance. BTW, I start a number of threads with different orchestrators, balances and ports. Please consider thread safety also.

    Read the article

  • python,running command line servers - they're not listening properly

    - by deepblue
    hello all Im attempting to start a server app (in erlang, opens ports and listens for http requests) via the command line using pexpect (or even directly using subprocess.Popen()). the app starts fine, logs (via pexpect) to the screen fine, I can interact with it as well via command line... the issue is that the servers wont listen for incoming requests. The app listens when I start it up manually, by typing commands in the command line. using subprocess/pexpect stops the app from listening somehow... when I start it manually "netstat -tlp" displays the app as listening, when I start it via python (subprocess/pexpect) netstat does not register the app... I have a feeling it has something to do with the environemnt, the way python forks things, etc. Any ideas? thank you

    Read the article

  • TCP echo server

    - by khera-satinder
    I have written a code for TCP echo server code in C i.e. whatever I receive I have to send it back. I am also successful in doing so but I am facing a problem. Sometimes the packets that are received are not echoed back. For this I have introduced a delay after receiving and the no. of failures reduced but the problem still exists. Can someone suggest something? Later on I would like to run two server applications simultaneously on two different ports. Regards, Satinder Singh

    Read the article

  • NLB and Host Header Value

    - by Hafeez
    Background: We are using MOSS 2007 in farm configuration, 2 WFE, 1 Indexer and SQL Server. MS NLB is used for load balancing. Host header value mapped to Virtual IP of Cluster in DNS, is used while creating the web applications in MOSS and all are sharing port 80. Problem: When client tries to access the web application that are configured with host header values. Both of WFEs Hangs for 5 minutes, they stop responding to ping and browser shows 'Page not found'. In the Application Log on the WFE, this error is registered "provider: TCP Provider, error: 0 - The semaphore timeout period has expired". Interestingly, the web application with no host header value and hosted on different ports is working correctly. Any clue to solve this problem will be helpful. Thks. Hafeez

    Read the article

  • Get Hardware Information for HWs that is not installed

    - by Isaac
    I am pretty sure how to retrieve hardware information with WMI classes. but WMIs have a big limitation: They Just can get information for installed hardwares. I need to retrieve information about CPU (model,speed,etc..),Video Card, Sound Card, USB Ports, etc. I found a really good software (HWiNFO) that can do this even the drivers for hardware parts is not installed. It seems that HWiNFO uses a internal database to give a name for each hardware part. So is there any free library/DLL/component that can do this in Windows XP or higher Note: Although HWiNFO SDK seems good, it's not free. So it doesn't exist! ;) I need a free library.

    Read the article

  • Consuming a USB HID device in Windows CE 6.0 using c#

    - by kersny
    I am working on an Embedded Windows CE project and am interested in accessing a USB HID device through one of its USB Host ports. All I really need to read are the raw HID spec packets. On a windows computer, I have a working program using hid.dll, but as far as I have researched, there is no equivalent on CE. I know there is the usbhid.dll, but I'm not sure if it is applicable for this situation. I would prefer not to write a kernel level driver, as I would like to do my coding in c#. Has anyone had experience consuming an HID device on Windows CE?

    Read the article

  • What is the meaning of this Web kit JavaScript warning? (Thickbox)?

    - by janoChen
    Webkit Develoepr tools says the following Javascript Error: Unsafe JavaScript attempt to access frame with URL file:///D:/wamp/www/projects/c1-marching-band2/instruments.html from frame with URL file:///D:/wamp/www/projects/c1-marching-band2/iframeModal.html?placeValuesBefore. Domains, protocols and ports must match. file:///D:/wamp/www/projects/c1-marching-band2/iframeModal.html?placeValuesBefore:15Uncaught TypeError: Property 'tb_remove' of object [object DOMWindow] is not a function I'm trying to close the Thickbox div (iframe) pressing a submit button. But I think there's something wrong with 'tb_remove'. (Just in Chrome) It doe work in their official page: http://jquery.com/demo/thickbox/

    Read the article

  • Adobe Socket Policy File Server Problems

    - by Matt
    Has anyone been able to successfully implement a service to serve the required socket policy file to FlashPlayer? I am running the Python implementation of the service provided by Adobe at http://www.adobe.com/devnet/flashplayer/articles/socket_policy_files.html and using the following policy file: <?xml version="1.0" encoding="UTF-8"?> <cross-domain-policy> <site-control permitted-cross-domain-policies="master-only"/> <allow-access-from domain="*" to-ports="*" secure="false"/> </cross-domain-policy> and receiving this message from Flash: [SecurityErrorEvent type="securityError" bubbles=false cancelable=false eventPhase=2 text="Error #2048: Security sandbox violation: http://www.mapopolis.com/family/Tree.swf cannot load data from www.mapopolis.com:1900."] Thanks.

    Read the article

  • Multiple routers, subnets, gateways etc

    - by allentown
    My current setup is: Cable modem dishes out 13 static IP's (/28), a GB switch is plugged into the cable modem, and has access to those 13 static IP's, I have about 6 "servers" in use right now. The cable modem is also a firewall, DHCP server, and 3 port 10/100 switch. I am using it as a firewall, but not currently as a DHCP server. I have plugged into the cable modem, two network cables, one which goes to the WAN port of a Linksys Dual Band Wireless 10/100/1000 router/switch. Into the linksys are a few workstations, a few printers, and some laptops connecting to wifi. I set the Linksys to use take static IP, and enabled DHCP for the workstations, printers, etc in 192.168.1.1/24. The network for the Linksys is mostly self contained, backups go to a SAN, on that network, it all happens through that switch, over GB. But I also get internet access from it as well via the cable modem using one static IP. This all works, however, I can not "see" the static IP machines when I am on the Linksys. I can get to them via ssh and other protocols, and if I want to from "outside", I open holes, like 80, 25, 587, 143, 22, etc. The second wire, from the cable modem/fireall/switch just uplinks to the managed GB switch. What are the pros and cons of this? I do not like giving up the static IP to the Linksys. I basically have a mixed network of public servers, and internal workstations. I want the public servers on public IP's because I do not want to mess with port forwarding and mappings. Is it correct also, that if someone breaches the Linksys wifi, they still would have a hard time getting to the static IP range, just by nature of the network topology? Today, just for a test, I toggled on the DHCP in the firewall/cable modem at 10.1.10.1/24 range, the Linksys is n the 192.168.1.100/24 range. At that point, all the static IP machines still had in and out access, but Linksys was unreachable. The cable modem only has 10/100 ports, so I will not plug anything but the network drop into it, which is 50Mb/10Mb. Which makes me think this could be less than ideal, as transfers from the workstation network to the server network will be bottlenecked at 100Mb when I have 1000Mb available. I may not need to solve that, if isolation is better though. I do not move a lot of data, if any, from Linsys network to server network, so for it to pretend to be remote is ok. Should I approach this any different? I could enable DHCP on the cable modem/firewall, it should still send out the statics to the GB switch, but will also be a DHCP in 10.1.10.1/24 range? I can then plug the Linksys into the GB switch, which is now picking up statics and the 10.1.10.1/24 ranges, tell the Linksys to use 10.1.10.5 or so. Now, do I disable DHCP on the Linksys, and the cable modem/firewall will pass through the statics and 10.0.10.1/24 ranges as well? Or, could I open a second DHCP pool on the Linksys? I guess doing so gives me network isolation again, but it is just the reverse of what I have now. But I get out of the bottleneck, not that the Linksys could ever really touch real GB speeds anyway, but the managed switch certainly can. This is all because 13 statics are not that many. Right now, 6 "servers", the Linksys, a managed switch, a few SSL certs, and I am running out. I do not want to waste a static IP on the managed GB switch, or the Linksys, unless it provides me some type of benefit. Final question, under my current setup, if I am on a workstation, sitting at 192.168.1.109, the Linksys, with GB, and I send a file over ssh to the static IP machine, is that literally leaving the internet, and coming back in, or does it stay local? To me it seems like: Workstation (192.168.1.109) -> Linksys DHCP -> Linksys Static IP -> Cable Modem -> Server ( and it hits the 10/100 ports on the cable modem, slowing me down. But does it round trip the network, leave and come back in, limiting me to the 50/10 internet speeds? *These are all made up numbers, I do not use default router IP's as I will one day add a VPN, and do not want collisions. I need some recommendations, do I want one big network, or two isolated ones. Printers these days need an IP, everything does, I can not get autoconf/bonjour to be reliable on most printers. but I am also not sure I want the "server" side of my operation to be polluted by the workstation side of my operation. Unless there is some magic subetting I have not learned yet, here is what I am thinking: Cable modem 10/100, has 13 static IP, publicly accessible -> Enable DHCP on the cable modem -> Cable modem plugs into managed switch -> Managed switch gets 10.1.10.1 ssh, telnet, https admin management address -> Managed switch sends static IP's to to servers -> Plug Linksys into managed switch, giving it 10.1.10.2 static internally in Linksys admin -> Linksys gets assigned 10.1.10.x as its DHCP sending range -> Local printers, workstations, iPhones etc, connect to this -> ( Do I enable DHCP or disable it on the Linksys, just define a non over lapping range, or create an entirely new DHCP at 10.1.50.0/24, I think I am back isolated again with that method too? ) Thank you for any suggestions. This is the first time I have had to deal with less than a /24, and most are larger than that, but it is just a drop to a cabinet. Otherwise, it's a router, a few repeaters, and soho stuff that is simple, with one IP. I know a few may suggest going all DHCP on the servers, and I may one day, just not now, there has been too much moving of gear for me to be interested in that, and I would want something in the Catalyst series to deal with that.

    Read the article

  • Optimize grep, awk and sed shell stuff

    - by kockiren
    I try to sum the traffic of diffrent ports in the logfiles from "IPCop" so i write and command for my shell, but i think its possible to optimize the command. First a Line from my Logfile: 01/00:03:16 kernel INPUT IN=eth1 OUT= MAC=xxx SRC=xxx DST=xxx LEN=40 TOS=0x00 PREC=0x00 TTL=98 ID=256 PROTO=TCP SPT=47438 DPT=1433 WINDOW=16384 RES=0x00 SYN URGP=0 Now i grep with following Command the sum of all lengths who contains port 1433 grep 1433 log.dat|awk '{for(i=1;i<=10;i++)if($i ~ /LEN/)print $i};'|sed 's/LEN=//g;'|awk '{sum+=$1}END{print sum}' The for loop i need because the LEN-col is not on same position at all time. Any suggestion for optimizing this command? Regards Rene

    Read the article

  • Out Of Memory error while executing mysqldump

    - by Nishaz Salam
    Hi, I am getting the following error when trying to backup a database using mysqldump from the command prompt. C:\Documents and Settings\bobC:\Adobe\LiveCycle8.2\mysql\bin\mysqldump --quick --add-locks --lock-tables -c --default-character-set=utf8 --skip-opt -pxxxx -u adobe -r C:\Adobe\LiveCycle8.2\configurationManager\working\upgrade\mysql\adobe. sql -B adobe --port=3306 --host=localhost mysqldump: Out of memory (Needed 10380928 bytes) mysqldump: Got error: 2008: MySQL client ran out of memory when retrieving data from server As you can see i am using the --quick and --skip-opt too; cannot figure out what is causing the issue. The server log has the following messages 100420 15:16:39 InnoDB: Error: cannot allocate 4814100 bytes of memory for InnoDB: a BLOB with malloc! Total allocated memory InnoDB: by InnoDB 33427880 bytes. Operating system errno: 2 InnoDB: Check if you should increase the swap file or InnoDB: ulimits of your operating system. InnoDB: On FreeBSD check you have compiled the OS with InnoDB: a big enough maximum process size. 100420 15:16:40 InnoDB: Warning: could not allocate 3814100 + 1000000 bytes to retrieve InnoDB: a big column. Table name adobe/tb_form_data Any help on this regard is highly appreciated P.S: The backup works fine without any issues when i use the MYSQL Administrator, but since an external app( adobe livecycle installer) uses the above command to backup the database during install, i need to get this working. Thanks, Nishaz Salam

    Read the article

  • Multiple port asynchronous I/O over serialport in C#

    - by firoso
    I'm trying to write a test application for serial I/O (RS-232) with multiple units in C# and I'm running into an issue with my lack of threading experience so I'm soliciting feedback for a best known method. I've got a pool of COM ports COM1-16 each of which can read/write at any time and I need to be able to manage them simultaneously. Is this a situation for a thread pool? What is some guidance on structuring this applet? Edit: Upon review I was wondering is I really even need to do asynchronous threads here, I could just maintain states for each COM-port and do flow logic (i.e., statemachine) for each COM-port individually.

    Read the article

  • Django: tinyMCE and cross site javascript

    - by pistacchio
    Hi, follow this question, I was able to set some textareas in my admin page as richtext inputs. The most voted answer suggests to follow an example and is what i did. Also, it talks about a problem concerning "blank pages". I'm having the same problem and I'm not able to solve it. I have my media files served by a different server, so MEDIA_URL points to a different host with a different port. To simulate this in my dev environment, I also serve media files from a different port. Debugging the failing javascript, Chrome yelds: Unsafe JavaScript attempt to access frame with URL http://localhost:8000/admin/blog/post/add/ from frame with URL http://localhost:88/s3mangerie/js/tiny_mce/themes/advanced/image.htm. Domains, protocols and ports must match. How to solve this problem? Thanks

    Read the article

  • How do you control what your C compiler Optimizes?

    - by Jordan S
    I am writing the firmware for an embedded device in C using the Silicon Labs IDE and the SDCC compiler. The device architecture is based on the 8051 family. The function in question is shown below. The function is used to set the ports on my MCU to drive a stepper motor. It gets called in by an interrupt handler. The big switch statement just sets the ports to the proper value for the next motor step. The bottom part of the function looks at an input from a hall effect sensor and a number of steps moved in order to detect if the motor has stalled. The problem is, for some reason the second IF statement that looks like this if (StallDetector > (GapSize + 20)) { HandleStallEvent(); } always seems to get optimized out. If I try to put a breakpoint at the HandleStallEvent() call the IDE gives me a message saying "No Address Correlation to this line number". I am not really good enough at reading assembly to tell what it is doing but I have pasted a snippet from the asm output below. Any help would be much appreciated. void OperateStepper(void) { //static bit LastHomeMagState = HomeSensor; static bit LastPosMagState = PosSensor; if(PulseMotor) { if(MoveDirection == 1) // Go clockwise { switch(STEPPER_POSITION) { case 'A': STEPPER_POSITION = 'B'; P1 = 0xFD; break; case 'B': STEPPER_POSITION = 'C'; P1 = 0xFF; break; case 'C': STEPPER_POSITION = 'D'; P1 = 0xFE; break; case 'D': STEPPER_POSITION = 'A'; P1 = 0xFC; break; default: STEPPER_POSITION = 'A'; P1 = 0xFC; } //end switch } else // Go CounterClockwise { switch(STEPPER_POSITION) { case 'A': STEPPER_POSITION = 'D'; P1 = 0xFE; break; case 'B': STEPPER_POSITION = 'A'; P1 = 0xFC; break; case 'C': STEPPER_POSITION = 'B'; P1 = 0xFD; break; case 'D': STEPPER_POSITION = 'C'; P1 = 0xFF; break; default: STEPPER_POSITION = 'A'; P1 = 0xFE; } //end switch } //end else MotorSteps++; StallDetector++; if(PosSensor != LastPosMagState) { StallDetector = 0; LastPosMagState = PosSensor; } else { if (PosSensor == ON) { if (StallDetector > (MagnetSize + 20)) { HandleStallEvent(); } } else if (PosSensor == OFF) { if (StallDetector > (GapSize + 20)) { HandleStallEvent(); } } } } //end if PulseMotor } ... and the asm output for the the bottom part of this function... ; C:\SiLabs\Optec Programs\HSFW_HID_SDCC_2\MotionControl.c:653: if(PosSensor != LastPosMagState) mov c,_P1_4 jb _OperateStepper_LastPosMagState_1_1,00158$ cpl c 00158$: jc 00126$ C$MotionControl.c$655$3$7 ==. ; C:\SiLabs\Optec Programs\HSFW_HID_SDCC_2\MotionControl.c:655: StallDetector = 0; clr a mov _StallDetector,a mov (_StallDetector + 1),a C$MotionControl.c$657$3$7 ==. ; C:\SiLabs\Optec Programs\HSFW_HID_SDCC_2\MotionControl.c:657: LastPosMagState = PosSensor; mov c,_P1_4 mov _OperateStepper_LastPosMagState_1_1,c ret 00126$: C$MotionControl.c$661$2$8 ==. ; C:\SiLabs\Optec Programs\HSFW_HID_SDCC_2\MotionControl.c:661: if (PosSensor == ON) jb _P1_4,00123$ C$MotionControl.c$663$4$9 ==. ; C:\SiLabs\Optec Programs\HSFW_HID_SDCC_2\MotionControl.c:663: if (StallDetector > (MagnetSize + 20)) mov a,_MagnetSize mov r2,a rlc a subb a,acc mov r3,a mov a,#0x14 add a,r2 mov r2,a clr a addc a,r3 mov r3,a clr c mov a,r2 subb a,_StallDetector mov a,r3 subb a,(_StallDetector + 1) jnc 00130$ C$MotionControl.c$665$5$10 ==. ; C:\SiLabs\Optec Programs\HSFW_HID_SDCC_2\MotionControl.c:665: HandleStallEvent(); ljmp _HandleStallEvent 00123$: C$MotionControl.c$668$2$8 ==. ; C:\SiLabs\Optec Programs\HSFW_HID_SDCC_2\MotionControl.c:668: else if (PosSensor == OFF) jnb _P1_4,00130$ C$MotionControl.c$670$4$11 ==. ; C:\SiLabs\Optec Programs\HSFW_HID_SDCC_2\MotionControl.c:670: if (StallDetector > (GapSize + 20)) mov a,#0x14 add a,_GapSize mov r2,a clr a addc a,(_GapSize + 1) mov r3,a clr c mov a,r2 subb a,_StallDetector mov a,r3 subb a,(_StallDetector + 1) jnc 00130$ C$MotionControl.c$672$5$12 ==. ; C:\SiLabs\Optec Programs\HSFW_HID_SDCC_2\MotionControl.c:672: HandleStallEvent(); C$MotionControl.c$678$2$1 ==. XG$OperateStepper$0$0 ==. ljmp _HandleStallEvent 00130$: ret It looks to me like the compiler is NOT optimizing out this second if statement from the looks of the asm but if that is the case why does the IDE not allow me so set a breakpoint there? Maybe it's just a dumb IDE!

    Read the article

  • Authentication for SaaS

    - by josh
    What would be recommended as an authentication solution for a Software-as-a-service product? Specifically, my product would have clients that would typically have low information technology skills, potentially not even having an IT department within their organization. I would still like to have my application authenticate against their internal directory service (eDirectory, Active Directory, etc.). I don't want them, however, to have to open/forward ports (for instance, opening up port 636 so I can do LDAPS binds directly to their directory service). One idea I had was to have an application installed on a server within their organization's network that would backconnect to my service. This would be a persistant socket. When I need to authenticate a user, I send the credentials via the socket (encrypted) - the application then performs a bind/whatever to authenticate against the directory service and replies with OK/FAIL. What would you suggest? My goal here is to essentially have the client install an application within their network, with very little configuration or intervention.

    Read the article

  • How to find an available port?

    - by Roman
    I want to start a server which listen to a port. I can specify port explicitly and it works. But I would like to find a port in an automatic way. In this respect I have two questions. In which range of port numbers should I search for? (I used ports 12345, 12346, and 12347 and it was fine). How can I find out if a given port is not occupied by another software?

    Read the article

  • Subscribing to MSMQ over the internet

    - by Nathan Palmer
    I haven't been able to find a clear answer to this problem. Is there a good way to subscribe to a MSMQ through the internet? Ideally I need security both in authentication and encryption for this connection. But I would like the subscriber to act just like any other client that would be subscribed on the local network. I believe I have a couple of options here Expose the MSMQ ports publicly Put the MSMQ behind some type of WCF service (not sure if that works for a subscriber) What other options do I have? We're sitting in a .NET environment and the main problem domain that is trying to be solved is to change the remote connections from a pulling system to an event based system to reduce the load on the main server.

    Read the article

< Previous Page | 90 91 92 93 94 95 96 97 98 99 100 101  | Next Page >