  • iDRAC on Dell R710 and R720

    - by BT643
    I've called Dell twice to try and clarify this basic (or so I thought) question, but I've had two different answers so far. We have a Dell R710, and a Dell R720. Does DRAC come installed by default on either? Dell said it comes build into the motherboard on the R720 but the second time I rang, they said we didn't have it. Can anyone tell me if DRAC comes as standard on the R720? I'm aware we'll need a license as well, I'm just interested in the physical capability on the server. I've never used DRAC before and know next to nothing about it, so apologies if this seems blindingly simple. Thanks

    Read the article

  • Using a non-validated SED on a Dell R720

    - by a coder
    We were given a Dell R720 a couple years ago, and the machine currently has standard 300GB 3.5" SAS 15k drives. Our RAID controller is a Perc H710. We need to update our disks to FIPS 140-2 certified SED. According to Dell, they have only one tested/validated FIPS SED for this machine/controller, but it is a 7200rpm 3.5" unit. I'm showing that Dell offers a 600GB 15k FIPS SED in 3.5" configuration (Dell part number 342-0605), but they say they haven't validated or tested to know if it works. They informed us that we would not void our warranty in using this non-validated drive. How likely is it that our R720 with H710 controller will work with the non-validated drive? Are there significant differences in how drive manufacturers build SED that would prevent them from working consistently across different controllers?

    Read the article

  • Dell PowerEdge R720 - Corrupted RAID

    - by BT643
    Apologies in advance for the lengthy question. We have a Dell PowerEdge R720 server with: 2 x 136GB SAS drives in RAID 1 for the OS (Ubuntu Server 12.04) 6 x 3TB SATA drives in RAID 5 for data A few days ago we were getting errors when trying to access files on the large RAID 5 partition. We rebooted the server and got a message about the raid controller has found a foriegn config. We've had this before, and just needed to use Dell's RAID configuration utility to import foreign config on the RAID. Last time this worked, but this time, it started doing a disk check then we got this: FSCK has returned the following: "/dev/sdb1 inode 364738 has a bad extended attribute block 7 /dev/sdb1 unexpected inconsistency run fsck manually (i.e without -a or -p options) MOUNTALL fsck /ourdatapartition [1019] terminated with status 4 MOUNTALL filesystem has errors /ourdatapartition errors where found while checking the disk drive for /ourdatapartition Press F to fix errors, I to Ignore or M for Manual Recovery" We pressed F to try and fix the errors, but it eventually errored with: Inode 275841084, i_blocks is 167080, should be 0. Fix? yes Inode 275841141 has an invalid extend node (blk 2206761006, lblk 0) Clear? yes Inode 275841141, i_blocks is 227872, should be 0. Fix? yes Inode 275842303 has an invalid extend node (blk 2206760975, lblk 0) Clear? yes .... Error storing directory block information (inode=275906766, block=0, num=2699516178): Memory allocation failed /dev/sdb1: ***** FILE SYSTEM WAS MODIFIED ***** e2fsck: aborted /dev/sdb1: ***** FILE SYSTEM WAS MODIFIED ***** mountall: fsck /ourdatapartition [1286] terminated with status 9 mountall: Unrecoverable fsck error: /ourdatapartition We noticed one of the drive lights was not lit at all, and thought this may have failed and be the problem. We replaced the drive with a spare, and tried "F" to repair it again, but we keep just getting the same error as above. In the RAID configuration utility, all drives show as "online" and "optimal". We do have this data on another replicated server, so we're not worried about "recovering" anything, we just want to get the system back online asap. The server has 64 or 32GB memory, can't remember off the top of my head, but either way, with a 14TB RAID, I think it may still not be enough. Thanks EDIT - I checked the memory usage while fsck was running as suggested and after 2 or 3 minutes, it looked like this, using up nearly all of our servers memory: When it failed after 5 minutes or so with the error in my post, the memory immediately freed up again:

    Read the article

  • Set iDRAC IP Address on Ubuntu 12.04 without Reboot?

    - by BT643
    We have a Dell PowerEdge R720XD server and want to setup iDRAC, but this is a production server so we need to do it without a reboot if possible. We just need to set the IP address on the iDRAC but the servers do not have a front LCD panel so we cannot use this. The iDRAC will currently have the default 192.168.0.120 IP address but we are not on this IP range so cannot use this. We need to change it to 192.168.5.x. I've seen racadm mentioned, but before I start messing around installing this on Ubuntu, is this what we need? and will we be able to set the IP address on the DRAC with this? Thanks

    Read the article

  • LSI MegaRAID Expected Chip Temperature?

    - by Myles Gray
    We recently built a replicating SAN array from 2x Dell R720XD's, we are using LSI 9270-8i MegaRAID cards with CacheCade 2.0, BBU and Write Back cache enabled. Our cards are showing HUGE chip temperatures (97*C+ with NO disk activity!). Our R720's are in auto temp management mode so the max exhaust temp is 50*C. The MegaRAID cards are passively cooled and depend on good airflow to cool them - however is 97*C normal? - I have seen reference to 60*C max ambients but nothing for chip temp.

    Read the article

  • 8Gb Fiber Channcel HBA vs. 10 Gb SPF+ Converged HBA

    - by Hossein Aarabi
    I am putting a Dell server together, more specifically R720. I have to select the correct Host Bus Adapter. This HBA on R710 will connect to a storage device. I am confused between these two: QLogic 2562, Dual Port 8Gb Optical Fiber Channel HBA (price $2,045) QLogic 8262, Dual Port 10Gb SFP+, Converged Network Adapter (price $1,618) I thought since the QLogic 2562 is a fiber channel and is more expensive then it is faster in terms of IOPS. But, it is a 8Gb as opposed to 10 Gb of SFP+. My questions: Which one is better (IOPS performance, etc.)? Why should I choose one over another?

    Read the article

  • How to make RHEL have persistent local hdd name?

    - by Mxx
    I have 2 identical Dell R720 servers running identical Oracle Enterprise Linux(RHEL)6.4. Both servers (supposedly) configured in exactly the same way. However, one of the servers is behaving differently. Every other reboot its local HDD name(and related partitions) flip from /dev/sda to /dev/sdj. This is problematic because both servers are configured for multipathd, and if this flip happens their config does not match and Oracle DB(or its clusterware) complains that nodes are not configured identically. Why does one server has a consistent device names while the other server keeps flipping back and forth? How can I make local hdd to consistently be /dev/sda? I suspect this might have something to do with udev but I'm not sure.

    Read the article

  • E: mkinitramfs failure cpio 141 gzip 1

    - by Nagaraj Shindagi
    I'm using Ubuntu 12.04 LTS with Dell power-edge R720 server, facing the problem when I apt-get -f install Reading package lists... Done Building dependency tree Reading state information... Done 0 upgraded, 0 newly installed, 0 to remove and 0 not upgraded. 2 not fully installed or removed. After this operation, 0 B of additional disk space will be used. Setting up linux-image-3.2.0-37-generic-pae (3.2.0-37.58) ... Running depmod. update-initramfs: deferring update (hook will be called later) The link /initrd.img is a dangling linkto /boot/initrd.img-3.2.0-37-generic-pae Examining /etc/kernel/postinst.d. run-parts: executing /etc/kernel/postinst.d/initramfs-tools 3.2.0-37-generic-pae /boot/vmlinuz-3.2.0-37-generic-pae update-initramfs: Generating /boot/initrd.img-3.2.0-37-generic-pae gzip: stdout: No space left on device E: mkinitramfs failure cpio 141 gzip 1 update-initramfs: failed for /boot/initrd.img-3.2.0-37-generic-pae with 1. run-parts: /etc/kernel/postinst.d/initramfs-tools exited with return code 1 Failed to process /etc/kernel/postinst.d at /var/lib/dpkg/info/linux-image-3.2.0 -37-generic-pae.postinst line 1010. dpkg: error processing linux-image-3.2.0-37-generic-pae (--configure): subprocess installed post-installation script returned error exit status 2 dpkg: dependency problems prevent configuration of linux-image-generic-pae: linux-image-generic-pae depends on linux-image-3.2.0-37-generic-pae; however: Package linux-image-3.2.0-37-generic-pae is not configured yet. dpkg: error processing linux-image-generic-pae (--configure): dependency problems - leaving unconfigured No apport report written because the error message indicates its a followup erro r from a previous failure. Errors were encountered while processing: linux-image-3.2.0-37-generic-pae linux-image-generic-pae E: Sub-process /usr/bin/dpkg returned an error code (1) ------------ even i tried with apt-get clean apt-get remove apt-get autoremove apt-get purge there is no difference it will show the same error message as above, even i checked the disk space ----------- Filesystem 1K-blocks Used Available Use% Mounted on /dev/sda6 24030076 612456 22196964 3% / udev 16536644 4 16536640 1% /dev tmpfs 6618884 1164 6617720 1% /run none 5120 0 5120 0% /run/lock none 16547208 72 16547136 1% /run/shm cgroup 16547208 0 16547208 0% /sys/fs/cgroup /dev/sda1 93207 75034 13361 85% /boot /dev/sda10 9611492 1096076 8027176 13% /tmp /dev/sda12 9611492 226340 8896912 3% /opt /dev/sda13 9611492 152516 8970736 2% /srv /dev/sda7 9611492 592208 8531044 7% /home /dev/sda8 9611492 2656736 6466516 30% /usr /dev/sda9 9611492 696468 8426784 8% /var /dev/sda14 961237336 134563516 777845764 15% /usr/data /dev/sda15 618991384 84498388 503050052 15% /usr/data1 /dev/sda11 9611492 152616 8970636 2% /usr/local --------------- is there any problem on allotting the space to the partiations please let me know the solution its on urgent please help me on this issue regards

    Read the article

  • ArchBeat Link-o-Rama Top 10 for August 2012

    - by Bob Rhubart
    The Top 10 most popular items shared via the OTN ArchBeat Facebook page for the month of August 2012. Now Available: Oracle SQL Developer 3.2 (3.2.09.23) New features include APEX listener, UI enhancements, and 12c database support. The Role of Oracle VM Server for SPARC in a Virtualization Strategy In this article, Matthias Pfutzner discusses hardware, desktop, and operating system virtualization, along with various Oracle virtualization technologies, including Oracle VM Server for SPARC. How to Manually Install Flash Player Plugin to see the Oracle Enterprise Manager Performance Page | Kai Yu So, you're a DBA and you want to check the Performance page in Oracle Enterprise Manager (11g or 12c). So you click the Performance tab and… nothing. Zip. Nada. The Flash plugin is a no-show. Relax! Oracle ACE Director Kai Yu shows you what you need to do to see all the pretty colors instead of that dull grey screen. Relationally Challenged (CX - CRM - EQ/RQ/CRQ) | Chris Warticki Self-proclaimed Oracle Support "spokesmodel" Chris Chris Warticki has some advice for those interested in Customer Relationship Management: "How about we just dumb it down, strip it to the core, keep it simple and LISTEN?! No more focus groups, no more surveys, and no need to gather more data. We have plenty of that. Why not just provide the customer what they are asking for?" Free WebLogic Server Course | Middleware Magic So you want to sharpen your Oracle WebLogic Server skills, but you prefer to skip the whole classroom bit and don't want to be bothered with dealing with an instructor? No problem! Oracle ACE Rene van Wijk, a prolific Middleware Magic blogger, has information on an Oracle WebLogic course you can take on your own time, at your own pace. Oracle VM VirtualBox 4.1.20 released Oracle VM VirtualBox 4.1.20 was just released at the community and Oracle download sites, reports the Fat Bloke. This is a maintenance release containing bug fixes and stability improvements. Optimizing OLTP Oracle Database Performance using Dell Express Flash PCIe SSDs | Kai Yu Oracle ACE Director Kai Yu shares resources based on "several extensive performance studies on a single node Oracle 11g R2 database as well as a two node 11gR2 Oracle Real Application clusters (RAC) database running on Dell PowerEdge R720 servers with Dell Express Flash PCIe SSDs on Oracle Enterprise Linux 6.2 platform." Oracle ACE sessions at Oracle OpenWorld With so many great sessions at this year's event, building your Oracle OpenWorld schedule can involve making a lot of tough choices. But you'll find that the sessions led by Oracle ACEs just might be the icing on the cake for your OpenWorld experience. MySQL Update: The Cleveland MySQL Meetup (Independence, OH) Oracle MySQL team member Benjamin Wood, a MySQL engineer and five year veteran of the MySQL organization, will speak at the Cleveland MySQL Meetup event on September 12. The presentation will include a MySQL 5.5 Overview, Oracle's Roadmap for MySQL, including specifics on MySQL 5.6, best practices and how to overcome development and operational MySQL challenges, and the new MySQL commercial extensions. Click the link for time and location information. Parsing XML in Oracle Database | Martijn van der Kamp Martijn van der Kamp's post deals with processing XML in PL/SQL code and processing the data into the database. Thought for the Day "Walking on water and developing software from a specification are easy if both are frozen." — Edward V. Berard Source: SoftwareQuotes.com

    Read the article

  • "power limit notification" clobbering on 12G Dell servers with RHEL6

    - by Andrew B
    Server: Poweredge r620 OS: RHEL 6.4 Kernel: 2.6.32-358.18.1.el6.x86_64 I'm experiencing application alarms in my production environment. Critical CPU hungry processes are being starved of resources and causing a processing backlog. The problem is happening on all the 12th Generation Dell servers (r620s) in a recently deployed cluster. As near as I can tell, instances of this happening are matching up to peak CPU utilization, accompanied by massive amounts of "power limit notification" spam in dmesg. An excerpt of one of these events: Nov 7 10:15:15 someserver [.crit] CPU12: Core power limit notification (total events = 14) Nov 7 10:15:15 someserver [.crit] CPU0: Core power limit notification (total events = 14) Nov 7 10:15:15 someserver [.crit] CPU6: Core power limit notification (total events = 14) Nov 7 10:15:15 someserver [.crit] CPU14: Core power limit notification (total events = 14) Nov 7 10:15:15 someserver [.crit] CPU18: Core power limit notification (total events = 14) Nov 7 10:15:15 someserver [.crit] CPU2: Core power limit notification (total events = 14) Nov 7 10:15:15 someserver [.crit] CPU4: Core power limit notification (total events = 14) Nov 7 10:15:15 someserver [.crit] CPU16: Core power limit notification (total events = 14) Nov 7 10:15:15 someserver [.crit] CPU0: Package power limit notification (total events = 11) Nov 7 10:15:15 someserver [.crit] CPU6: Package power limit notification (total events = 13) Nov 7 10:15:15 someserver [.crit] CPU14: Package power limit notification (total events = 14) Nov 7 10:15:15 someserver [.crit] CPU18: Package power limit notification (total events = 14) Nov 7 10:15:15 someserver [.crit] CPU20: Core power limit notification (total events = 14) Nov 7 10:15:15 someserver [.crit] CPU8: Core power limit notification (total events = 14) Nov 7 10:15:15 someserver [.crit] CPU2: Package power limit notification (total events = 12) Nov 7 10:15:15 someserver [.crit] CPU10: Core power limit notification (total events = 14) Nov 7 10:15:15 someserver [.crit] CPU22: Core power limit notification (total events = 14) Nov 7 10:15:15 someserver [.crit] CPU4: Package power limit notification (total events = 14) Nov 7 10:15:15 someserver [.crit] CPU16: Package power limit notification (total events = 13) Nov 7 10:15:15 someserver [.crit] CPU20: Package power limit notification (total events = 14) Nov 7 10:15:15 someserver [.crit] CPU8: Package power limit notification (total events = 14) Nov 7 10:15:15 someserver [.crit] CPU10: Package power limit notification (total events = 14) Nov 7 10:15:15 someserver [.crit] CPU22: Package power limit notification (total events = 14) Nov 7 10:15:15 someserver [.crit] CPU15: Core power limit notification (total events = 369) Nov 7 10:15:15 someserver [.crit] CPU3: Core power limit notification (total events = 369) Nov 7 10:15:15 someserver [.crit] CPU1: Core power limit notification (total events = 369) Nov 7 10:15:15 someserver [.crit] CPU5: Core power limit notification (total events = 369) Nov 7 10:15:15 someserver [.crit] CPU17: Core power limit notification (total events = 369) Nov 7 10:15:15 someserver [.crit] CPU13: Core power limit notification (total events = 369) Nov 7 10:15:15 someserver [.crit] CPU15: Package power limit notification (total events = 375) Nov 7 10:15:15 someserver [.crit] CPU3: Package power limit notification (total events = 374) Nov 7 10:15:15 someserver [.crit] CPU1: Package power limit notification (total events = 376) Nov 7 10:15:15 someserver [.crit] CPU5: Package power limit notification (total events = 376) Nov 7 10:15:15 someserver [.crit] CPU7: Core power limit notification (total events = 369) Nov 7 10:15:15 someserver [.crit] CPU19: Core power limit notification (total events = 369) Nov 7 10:15:15 someserver [.crit] CPU17: Package power limit notification (total events = 377) Nov 7 10:15:15 someserver [.crit] CPU9: Core power limit notification (total events = 369) Nov 7 10:15:15 someserver [.crit] CPU21: Core power limit notification (total events = 369) Nov 7 10:15:15 someserver [.crit] CPU23: Core power limit notification (total events = 369) Nov 7 10:15:15 someserver [.crit] CPU11: Core power limit notification (total events = 369) Nov 7 10:15:15 someserver [.crit] CPU13: Package power limit notification (total events = 376) Nov 7 10:15:15 someserver [.crit] CPU7: Package power limit notification (total events = 375) Nov 7 10:15:15 someserver [.crit] CPU19: Package power limit notification (total events = 375) Nov 7 10:15:15 someserver [.crit] CPU9: Package power limit notification (total events = 374) Nov 7 10:15:15 someserver [.crit] CPU21: Package power limit notification (total events = 375) Nov 7 10:15:15 someserver [.crit] CPU23: Package power limit notification (total events = 374) A little Google Fu reveals that this is typically associated with the CPU running hot, or voltage regulation kicking in. I don't think that's what is happening though. Temperature sensors for all servers in the cluster are running fine, Power Cap Policy is disabled in the iDRAC, and my System Profile is set to "Performance" on all of these servers: # omreport chassis biossetup | grep -A10 'System Profile' System Profile Settings ------------------------------------------ System Profile : Performance CPU Power Management : Maximum Performance Memory Frequency : Maximum Performance Turbo Boost : Enabled C1E : Disabled C States : Disabled Monitor/Mwait : Enabled Memory Patrol Scrub : Standard Memory Refresh Rate : 1x Memory Operating Voltage : Auto Collaborative CPU Performance Control : Disabled A Dell mailing list post describes the symptoms almost perfectly. Dell suggested that the author try using the Performance profile, but that didn't help. He ended up applying some settings in Dell's guide for configuring a server for low latency environments and one of those settings (or a combination thereof) seems to have fixed the problem. Kernel.org bug #36182 notes that power-limit interrupt debugging was enabled by default, which is causing performance degradation in scenarios where CPU voltage regulation is kicking in. A RHN KB article (RHN login required) mentions a problem impacting PE r620 and r720 servers not running the Performance profile, and recommends an update to a kernel released two weeks ago. ...Except we are running the Performance profile... Everything I can find online is running me in circles here. What's the heck is going on?