  • SAS vs Near-line SAS vs SATA

    - by David
    I'm unsure about the differences in these storage interfaces. My Dell servers all have SAS RAID controllers in them and they seem to be cross-compatible to an extent. The Ultra-320 SCSI RAID controllers in my old servers were simple enough: One type of interface (SCA) with special drives with special controllers, humming at 10-15K RPM. But these SAS/SATA drives seem like the drives I have in my desktop, only more expensive. Also my old SCSI controllers have their own battery backup and DDR buffer - neither of these things are present on the SAS controllers. What's up with that? "Enterprise" SATA drives are compatible with my SAS RAID controller, but I'd like to know what advantage SAS drives have over SATA drives as they seem to have similar specs (but one is a lot cheaper). Also, how do SSDs fit into this? I remember when RAID controllers required HDDs to spin at the same rate (as if the controller card supplanted the controller in the drive) - so how does that work out now? And what's the deal with Near-line SATA? I apologise about the rambling tone in this message, it's 5am and I haven't slept much.

    Read the article

  • SAS unifie la vision des risques pour les banques avec SAS Risk Management for Banking

    SAS unifie la vision des risques pour les banques Avec SAS Risk Management for Banking SAS lance SAS Risk Management for Banking, une solution intégrée dédiée à la gestion des risques dans le secteur de la banque. Cette solution exploite les fonctionnalités de la plate-forme SAS Business Analytics dans le domaine de l'intégration des données, de l'analyse et du reporting. « Ses fonctionnalités de gestion des risques répondent aux exigences en matière de normes réglementaires et de besoins de performance des différentes entités métier », souligne l'éditeur. SAS Risk Management for Banking couvre le processus complet allant de la gestion des données au reportin...

    Read the article

  • SAN performance issues storing SQL Server tempdb on a SAN that's being backed up

    - by user42724
    I'm afraid I don't know much about SAN's so please forgive my lack of detail or technical terms. As a developer I've just completed and put on an existing production system a new application but it would appear to have tipped the scales regarding the performance of the backups being taken from the SAN. As I understand it there's a mirror of the SAN being taken usually constantly at the block-level. However, there seem to be so many new writes to the disk that the SAN mirroring/backup process can no longer keep up. I believe I've narrowed this down to SQL Servers tempdb which exists on a drive that contributes the largest portion of the problem! In fact I think tempdb has be contributing the largest portion of the issues all along regardless of my application! My question therefore is whether the tempdb should ever be mirrored or backed on the SAN and whether anyone else has gone through this sort of pain already? I'm wondering whether it's a best practise to make sure that tempdb is never mirrored on a SAN simply because any writes to it don't need to be saved. This also raises a slightly connected question - is it better to rely on SQL Servers built-in database backups tools (DB in full-recovery mode with full/differential and transaction log backups) or, as is the case with our application, SQL server is in simple recovery mode and never backed up since the SAN is mirrored and backed up? Many thanks

    Read the article

  • DAS vs SAN storage for serving 2 to 4 nodes

    - by Luke404
    We currently have 4 Linux nodes with local storage, arranged in two active/passive pairs with storage mirrored using DRBD, running virtual machines (actually using Xen Hypervisor) for typical hosting workloads (mail, web, a couple VPS, etc.). We're approaching the (presumed) maximum IOPS of those servers, and we're planning to migrate to an external storage solution with two active nodes, with capacity for up to four active nodes. Since we're an all-Dell shop I've done some research and found the MD3200 / MD3200i products should be the ones we're looking for. We are pretty sure we won't be attaching more than 4 hosts on a single storage and I'm wondering if there is any clear advantage for one or the other. In theory I should be able to attach 4 SAS hosts to a single MD3200 (single links on a single controller MD3200, or dual redundant SAS links from each host to a dual-controller MD3200), or 4 iSCSI hosts to a single MD3200i (directly on its 4 GigE ports without any switch, again with dual links for the dual controller option). Both setups should let us implement live VM migration since all hosts can access all the LUNs at the same time, and also some shared filesystem like GFS2 or OCFS2. Also, both setups should allow full redundancy of the whole system (assuming dual controllers in the storage). One difference I can see is that the DAS solution is actually limited to 4 hosts while the iSCSI one should be able to grow to more hosts (adding two GigE switches to the mix). One point for the iSCSI solution is that it would allow us to start out with our current nodes and upgrade them at a later time (we can't add other SAS controllers, but they already have 4 GigE ports each). With the right (iSCSI|SAS) controllers I should be able to connect diskless nodes and boot them off the external storage which I think is a good thing (get rid of any local storage). On the other hand, I would have thought the SAS one to be cheaper but it seems like an MD3200 actually costs a little less than an MD3200i (?) (please note: I've used Dell gear in my examples since that's what we're looking for but I assume the same goes with other vendors) I would like to know if my assumptions above are correct, and if I'm missing any important difference between the two setups.

    Read the article

  • Connection lost to iscsi san after problem with san

    - by marceldejager
    Hi there, We have a cluster running with 3 VSpere ESX4 server that all are connected to a lefthand san through iSCSI. This all worked well but a week ago there was a problem with the san. After fixing that problem the VMWARE server continued working but this weekend I saw that 1 server didn't have a connection with the SAN. The other two work perfecly. I looked at all setting and I cannot find a problem. Nowhere I can't find any erros. Has anybode a idea? Thanks, Marcel

    Read the article

  • Is the SAN dying???

    - by RickHeiges
    Is the SAN dying? The reason that I ask this question is that MSFT has unleashed technologies this year that point in that direction Always ON Availability Groups shuns shared storage Windows 2012 has Storage Replication Technology that does not require a SAN Windows 2012 has Hyper-V Replica Technology that does not require a SAN PDW v2 continues to reinforce the approach to avoid shared storage I'm not saying that SAN technology does not have its place or does not have benefits inherent to the beast....(read more)

    Read the article

  • What is the max supported number of SATA devices (using cable adapters) on a Dell SAS 6/iR adapter?

    - by Zac B
    I've got a Dell SAS 6/iR PCI-E adapter. I don't have a multiplier backplane. I'm planning on connecting SATA (non SAS) drives. If I buy cable adapters only (ones that split a SAS connector on the card to a certain number of SATA cables), how many drives can I connect to this card? The way I see it, there are two limitations: a limitation imposed by the theoretical max number of devices supported on the card (which I've dug through the specs to find, but haven't seen yet), and a limitation imposed by the number of SAS plugs on the card multiplied by the number of SATA cables that come out of the highest-multiplying splitter I can buy. The answer to my question would be the minimum of those two limitations. I've seen 4x SATA coming out of some splitters; are there any that have more? Alternatively, if this is an RTFM question, does anyone have a good link to a "this is how SAS works, this is how you figure out the max number of devices, and this is how the concepts of 'ports', 'lanes', 'endpoint devices', and 'connectors' all relate in SAS-land" document? I've looked around on the Dell docs, but haven't found anything that explains this to someone at my level of understanding of SAN/enterprise storage technologies. Cheers!

    Read the article

  • SAS Array with or without expander

    - by tegbains
    Is it better to use a SAS Expander backplane for 12 drives via one SAS connection or is it better to use a SAS backplane with 3 SAS connections? This is in terms of performance, rather than expansion. This array will be setup using ZFS on a OpenSolaris via a LSI SAS controller as an iSCSI target. The two products being considered are the SuperMicro SuperChassis 826A-R1200LPB or the SuperChassis 826E2-R800LPB

    Read the article

  • Any experience with SATA SAS Interposer Cards?

    - by korkman
    Driven by the current price difference between SATA and SAS disks on one side and the potentially bad behaviour of SATA disks in bigger storage arrays on the other side, I have found so-called SATA-to-SAS interposer cards. Advertised as "seamlessly adding SAS capabilities to existing SATA disk drives", I wonder if anyone here has had some experience with these or similar products. The major benefits I can identify are the increased cable voltage (if all drives are SAS connected), the ability to power-cycle the drive and multipath (if desired). Obviously the SATA drive will still have to be RAID edition. The question is: Do these cards indeed increase the overall reliability of a storage system, or will failing SATA disks cause trouble nevertheless? Edit: I'm not asking for hypothetical answers, only actual experience please. I'm well aware that the typical 10k SAS drive is more reliable (and better performing) than 7200 SATA drives. But how does a nearline SAS, which is phyiscally the same disk as its SATA counterpart, compare to the SATA version with interposer?

    Read the article

  • Using SAS Macro to pipe a list of filenames from a Windows directory

    - by Bazil
    I am trying to amend the macro below to accept a macro parameter as the 'location' argument for a dir command. However I cannot get it to resolve correctly due to the nested quotes issue. Using %str(%') does not work, neither do quoting functions for some reason. The macro will work fine when the filepath has no spaces (eg C:\temp\withnospace) as the middle quotes aren't needed. However I need this macro to work for filepaths with spaces (eg 'C:\temp\with space\'). Please help! %macro get_filenames(location) filename pipedir pipe "dir &location. /b " lrecl=32767; data filenames; infile pipedir truncover; input line $char1000.; run; %mend; %get_filenames(C:\temp\) /* works */ %get_filenames('C:\temp\with space') /* doesnt work */

    Read the article

  • SAN with iSCSI-Target Performance Horrendous

    - by Justin
    We have a poor man's SAN setup in a 1U Ubuntu server running iSCSI-Target with two 300GB drives in RAID-0. We then are using it for block level storage for virtual machines. The hypervisor is connected to the SAN via gigabit on a dedicated VLAN and interfaces. We only have a single virtual machine setup and doing some benchmarks. If we run hdparm -t /dev/sda1 from the virtual machine, we get 'ok' performance of 75MB/s from the virtual machine to the SAN. Then we basically compile a package with ./configure and make. Things start ok, but then all the sudden the load average on the SAN grows to 7+ and things slow down to a crawl. When we SSH into the SAN and run top, sure the load is 7+, but the CPU usage is basically nothing, also the server has 1.5GB of memory available. When we kill the compile on the virtual machine, slowly the LOAD on the SAN goes back to sub 1 figures. What in the world is causing this? How can we diagnosis this further? Here are two screenshot from the SAN during high load. 1> Output of iotop on the SAN: 2> Output of top on the SAN:

    Read the article

  • GNU/Linux: SAS-disk detected as /dev/sg7 - not as /dev/sdb

    - by Ole Tange
    I have just installed a SAS disk into a Debian server. It was detected correctly and everything was fine. Then I moved the SAS disk to a different Debian server, the same hardware model and running same version of Debian, but here the SAS disk is detected as /dev/sg7 and not /dev/sdb. smartctl -a /dev/sg7 works fine, but fdisk and cat hang. I tried putting the SAS disk in another slot: Same problem. How can I force the SAS disk to be detected as /dev/sdb? # uname -a Linux maxwell 3.2.0-4-amd64 #1 SMP Debian 3.2.41-2+deb7u2 x86_64 GNU/Linux

    Read the article

  • What would be the ideal SAS package to integrate with a Enterprise scale web application developed using Java

    - by Rajesh
    SAS-Java Connectivity and Integration for a enterprise class web application - I am trying to narrow down the available approaches to connect to SAS frm Java. I am asusming the following , please correct my assumption if you think is not correct SAS ACCESS (ODBC, JDBC) /SAS Share Net- Query SAS Datasets using a JDBC Model SAS/Intr Net (For Connectivity with Java and build small scale applications) SAS Integration Technology (For Connectivity with Java and build Distributed Java Applications) Now the scenario is i need to build a enterprise class web application using Java/J2EE and ensure this application talks to SAS for Querying SAS Datasets Execute SAS Programs and generate Reports I am looking for a cost effective and robust solution which will work in a Multi user environment.

    Read the article

  • 2 Server FC SAN Configuration

    - by BSte
    I have 2 identical servers: -48GB Ram -8GigE NIC's -2FC NIC's -2x72GB RAID1 Hard Drives -Server 2008R2 Host I also Have a Fibre Channel SAN: -16x146GB RAID10 Hard Drives -2xDual-port FC Controllers (Controller A and B both have ports 1 and 2) -Server 1 has Fiber to Ports A1 and B1 -Server 2 has Fiber to Ports A2 and B2 -I kept the default config with 1 Virtual Disk and 1 Volume -The default mappings show ports A1,A2,B1,B2 on LUN 0 with read-write My goal is: -2xVM's with IIS and Guest Level Failover -2xVM's with SQL 2008 Enterprise using a Single DB and Guest Level Failover -1xVM that is an application server, preferable with Host Failover. From what I read, this will also need AD for clustering to work. -I need at least 1 VM always running for IIS and the SQLDB. This includes hardware failover and application (ie: reboot a VM for Critical updates) I was told I could install the VM's and run them from the SAN, and this is what I've tried: Installed MPIO and HyperV on Server1 and Server 2 Added the SAN as Disk E: on both servers, made it GPT and formatted NTFS Configured HyperV on both server to store use E:\VD and E:\VHD On server1, I was able to install 3 VM's on the SAN and all worked well. On server2, I would start installing the other 2 VM's, but always at some point the VM's would get a corrupt .VHD message (either server). Everything I found about the message typically related to antivirus, so I removed all antivirus on both Host servers (now only running 2008R2). I reformatted drive E: (SAN), recreated the VHD and VD directories, installed 3 VM's on Server 1, and then had the same issue when installing VM's on Server2. Obviously something is wrong, but I'm not certain what exactly. My questions: 1) Are my goals possible with this hardware setup? -I've read 2008R2 supports FC SAN's, but a lot of articles seem to only give examples with iSCSCI setups 2) What would be the suggested route on setting up the SAN (disks,volumes,LUN's)? I've worked with HyperV on a single machine before and never had issues. Actual experience working on SAN's and clustering is new to me. Any suggestions or recommendations to get me in the right direction would be much appreciated.

    Read the article

  • Disk names in Solaris 10 for ZFS: SAS WWN instead of c0t0d0

    - by notpeter
    I currently have a server running Solaris 10u9 with a SAS enclosure (Dell PowerVault MD1000) filled with SATA disks attached to an SAS card (LSI 3801E). It happily recognizes the 15 disks in the MD1000 and presents them each disk in the traditional solaris form (c1t12d0, c1t13d0, c1t15d0, etc). My home ZFS setup (Nexenta CP3 + LSI 9200-16E + directly cabled SATA disks) presents disks as their SAS WWN ID (ex: c3t600039300001EA56d0). Although this ID is longer, I've found it much easier to troubleshoot because the cabling/slot is irrelevant, ZFS just identifies the disk by ID, if it's connected it finds it. Most manufacturers print the WWN right on the disk's top label, can't get much easier than that. So how can I get Solaris to identify disks by SAS WWN instead of by the cXtXdX?

    Read the article

  • How Is A SAN Storage Device Managed? [closed]

    - by slickboy
    Apologies if this is a stupid question but my only previous experience with SAN technology is using a SAN virtualisation tool (StarWind iSCSI SAN Free). This tool comes with a management interface that allows for iSCSI targets to be configured on the simulated SAN that can then be accessed. My question is basically: How is physical SAN device managed? Is an operating system required to be installed on the SAN device and then managed via software? Or can it be managed remotely via an application with no OS on the device? Thanks for any help.

    Read the article

  • Running out of space on a SAS-based workstation

    - by SteveWilkinson
    Hi - first question on serverfault - pls excuse if asked elsewhere. I have a Dell Precision 690 with one 73GB (15000RPM) SAS drive in it. Running Windows 7 (x64) with a bunch of apps means it is running out of space. I have on order a 147GB (15000RPM) SAS drive (same GB/s, same make) which I want to put into the machine. Not knowing anything about SAS, do I need to replace the 73GB with the 147GB and restore from a backup, or can I put the drive in the machine and get the controller to treat the two drives as one large one? (The original paperwork for the machine says 73GB SAS (No RAID) if that is relevant.) Thanks in advance.

    Read the article

  • Running out of space on a SAS-based workstation

    - by SteveWilkinson
    Hi - first question on serverfault - pls excuse if asked elsewhere. I have a Dell Precision 690 with one 73GB (15000RPM) SAS drive in it. Running Windows 7 (x64) with a bunch of apps means it is running out of space. I have on order a 147GB (15000RPM) SAS drive (same GB/s, same make) which I want to put into the machine. Not knowing anything about SAS, do I need to replace the 73GB with the 147GB and restore from a backup, or can I put the drive in the machine and get the controller to treat the two drives as one large one? (The original paperwork for the machine says 73GB SAS (No RAID) if that is relevant.) Thanks in advance.

    Read the article

  • How can I connect a SAS drive to USB? [closed]

    - by dave
    I have a Dell T710 with Seagate Cheetah 15k.7 SAS disks. If the T710 motherboard dies, I'll need to resort to one of my nightly off-site backups and salvage the journal/logfile from the SAS disk to bring the backup bang up-to-date. I need a way of reading the healthy-but-inaccessible SAS disc that does not depend on the only SAS-capable machine I have to hand. So I bought: SAS to SATA Adapter and: USB 2.0 to SATA Adapter with Power ...so that I could read the SAS drive via USB. I can plug it all together just fine. The chain looks like: USB - SATA - SAS. But the drive does not spin up and the computer doesn't even acknowledge anything being attached by USB. Is there a cheap external enclosure I can buy for SAS drives? I can't believe these USB to SATA adapters are everywhere but the USB to SAS adapters are almost non-existent...

    Read the article

  • Improving SAS multipath to JBOD performance on Linux

    - by user36825
    Hello all I'm trying to optimize a storage setup on some Sun hardware with Linux. Any thoughts would be greatly appreciated. We have the following hardware: Sun Blade X6270 2* LSISAS1068E SAS controllers 2* Sun J4400 JBODs with 1 TB disks (24 disks per JBOD) Fedora Core 12 2.6.33 release kernel from FC13 (also tried with latest 2.6.31 kernel from FC12, same results) Here's the datasheet for the SAS hardware: http://www.sun.com/storage/storage_networking/hba/sas/PCIe.pdf It's using PCI Express 1.0a, 8x lanes. With a bandwidth of 250 MB/sec per lane, we should be able to do 2000 MB/sec per SAS controller. Each controller can do 3 Gb/sec per port and has two 4 port PHYs. We connect both PHYs from a controller to a JBOD. So between the JBOD and the controller we have 2 PHYs * 4 SAS ports * 3 Gb/sec = 24 Gb/sec of bandwidth, which is more than the PCI Express bandwidth. With write caching enabled and when doing big writes, each disk can sustain about 80 MB/sec (near the start of the disk). With 24 disks, that means we should be able to do 1920 MB/sec per JBOD. multipath { rr_min_io 100 uid 0 path_grouping_policy multibus failback manual path_selector "round-robin 0" rr_weight priorities alias somealias no_path_retry queue mode 0644 gid 0 wwid somewwid } I tried values of 50, 100, 1000 for rr_min_io, but it doesn't seem to make much difference. Along with varying rr_min_io I tried adding some delay between starting the dd's to prevent all of them writing over the same PHY at the same time, but this didn't make any difference, so I think the I/O's are getting properly spread out. According to /proc/interrupts, the SAS controllers are using a "IR-IO-APIC-fasteoi" interrupt scheme. For some reason only core #0 in the machine is handling these interrupts. I can improve performance slightly by assigning a separate core to handle the interrupts for each SAS controller: echo 2 /proc/irq/24/smp_affinity echo 4 /proc/irq/26/smp_affinity Using dd to write to the disk generates "Function call interrupts" (no idea what these are), which are handled by core #4, so I keep other processes off this core too. I run 48 dd's (one for each disk), assigning them to cores not dealing with interrupts like so: taskset -c somecore dd if=/dev/zero of=/dev/mapper/mpathx oflag=direct bs=128M oflag=direct prevents any kind of buffer cache from getting involved. None of my cores seem maxed out. The cores dealing with interrupts are mostly idle and all the other cores are waiting on I/O as one would expect. Cpu0 : 0.0%us, 1.0%sy, 0.0%ni, 91.2%id, 7.5%wa, 0.0%hi, 0.2%si, 0.0%st Cpu1 : 0.0%us, 0.8%sy, 0.0%ni, 93.0%id, 0.2%wa, 0.0%hi, 6.0%si, 0.0%st Cpu2 : 0.0%us, 0.6%sy, 0.0%ni, 94.4%id, 0.1%wa, 0.0%hi, 4.8%si, 0.0%st Cpu3 : 0.0%us, 7.5%sy, 0.0%ni, 36.3%id, 56.1%wa, 0.0%hi, 0.0%si, 0.0%st Cpu4 : 0.0%us, 1.3%sy, 0.0%ni, 85.7%id, 4.9%wa, 0.0%hi, 8.1%si, 0.0%st Cpu5 : 0.1%us, 5.5%sy, 0.0%ni, 36.2%id, 58.3%wa, 0.0%hi, 0.0%si, 0.0%st Cpu6 : 0.0%us, 5.0%sy, 0.0%ni, 36.3%id, 58.7%wa, 0.0%hi, 0.0%si, 0.0%st Cpu7 : 0.0%us, 5.1%sy, 0.0%ni, 36.3%id, 58.5%wa, 0.0%hi, 0.0%si, 0.0%st Cpu8 : 0.1%us, 8.3%sy, 0.0%ni, 27.2%id, 64.4%wa, 0.0%hi, 0.0%si, 0.0%st Cpu9 : 0.1%us, 7.9%sy, 0.0%ni, 36.2%id, 55.8%wa, 0.0%hi, 0.0%si, 0.0%st Cpu10 : 0.0%us, 7.8%sy, 0.0%ni, 36.2%id, 56.0%wa, 0.0%hi, 0.0%si, 0.0%st Cpu11 : 0.0%us, 7.3%sy, 0.0%ni, 36.3%id, 56.4%wa, 0.0%hi, 0.0%si, 0.0%st Cpu12 : 0.0%us, 5.6%sy, 0.0%ni, 33.1%id, 61.2%wa, 0.0%hi, 0.0%si, 0.0%st Cpu13 : 0.1%us, 5.3%sy, 0.0%ni, 36.1%id, 58.5%wa, 0.0%hi, 0.0%si, 0.0%st Cpu14 : 0.0%us, 4.9%sy, 0.0%ni, 36.4%id, 58.7%wa, 0.0%hi, 0.0%si, 0.0%st Cpu15 : 0.1%us, 5.4%sy, 0.0%ni, 36.5%id, 58.1%wa, 0.0%hi, 0.0%si, 0.0%st Given all this, the throughput reported by running "dstat 10" is in the range of 2200-2300 MB/sec. Given the math above I would expect something in the range of 2*1920 ~= 3600+ MB/sec. Does anybody have any idea where my missing bandwidth went? Thanks!

    Read the article

  • Lefthand SAN questions.

    - by Gk
    I'm curious about Lefthand SAN solutions from HP. People from Dell have told me that Lefthand SAN's require at least two nodes and data must be mirroring between them so capacity is a half less compare to other SAN technology (e.g.Equal Logic). Is it true? Can a HP lefhand SAN be used as a stand-alone storage server with full RAID function (1, 10, 5)? TIA, -giobuon

    Read the article

  • Lefthand SAN quetions.

    - by Gk
    I'm curios about Lefthand SAN solution from HP. Ppl from Dell told me that lefthand SAN require at least two nodes and data must be mirroring between them so capacity is a half less compare to other SAN technology (e.g.Equal Logic). Is it true? Can a HP lefhand SAN can use as a stand-alone storage server with full RAID function (1, 10, 5)? TIA, -giobuon

    Read the article