Search Results

Search found 74 results on 3 pages for 'supermicro'.

Page 1/3 | 1 2 3  | Next Page >

  • Entering BIOs Setup from Supermicro IPMI KVM

    - by Joshua Lim
    I'm having trouble getting into BIOs Setup from Supermicro IPMI "KVM" - Remote Control Console Redirection. I need to change the boot order to CDROM first. I'm running Windows 2008 server. After some Googling, it says here that the method is to: Press TAB to enter Setup screen. Press Esc twice to take effect. http://www.supermicro.com/support/faqs/faq.cfm?faq=6222 A month ago, I tried that 30-40 times + DEL, over 2 hours, it worked. Now, I've been trying the same key combination for more than an hour, rebooting each time it failed, it still doesn't work. Note: I've only got a notebook computer, no extra monitor.

    Read the article

  • SuperMicro IPMI through OpenBSD PF Firewall

    - by thelsdj
    I'm trying to access a SuperMicro IPMI card that is behind an OpenBSD bridged firewall. A couple pieces of information: The OpenBSD firewall itself has a SuperMicro IPMI that I can access across the internet. The IPMI I'm trying to reach can be reached from behind the firewall. My gateway does arp request the IPMI and it does appear to respond (this is from the external interface of the firewall) 16:57:45.548892 arp who-has ipminame tell gwname 16:57:45.549500 arp reply ipminame is-at ipmimac But when I make a request to the IPMI IP from outside the firewall the external interface of the firewall shows no traffic with the IPMI ip as its destination. Any idea what might be causing this problem? Is there something about IPMI traffic that my gateway wouldn't like (the gateway is provided by my colocation provider so I can't easily debug it).

    Read the article

  • Supermicro BIOS recovery - SUPER.ROM

    - by Goyuix
    I have a Supermicro X9SCL+-F motherboard that I flashed a beta BIOS to, then the flash went bad when I tried to flash back to the latest stable. I am attempting to recover using their SUPER.ROM recovery from a flash drive without success. I read in the manual that if I hold down Ctrl +Home  while powering on the server I can do a BIOS recovery from a flash drive. I hold down those keys, hear the desired two beeps and I can see the activity LED on the flash drive activate. Unfortunately, instead of the monitor turning on and allowing a BIOS recovery as the manual indicates, I hear five beeps, followed shortly after by 3 beeps. I grabbed the latest BIOS from their site (x9scm2.508.zip) and extracted it to my flash drive and renamed it to SUPER.ROM. Their instructions are not clear if any ROM can serve as the SUPER.ROM file, or if I need a special SUPER.ROM file to initiate the recovery at which time I can supply a known good ROM. Does anyone have any expertise in ROM recovery for Supermicro boards? Am I missing some key step? Can any known good ROM file function as the SUPER.ROM file for recovery?

    Read the article

  • Supermicro IPMI SSL

    - by churnd
    I have a Supermicro X9SCA-F serverboard and I'm trying to secure Super Doctor III IPMI by using SSL. I generated my own certs (done this many times before), uploaded via the web interface, then it said it needed to restart & I clicked OK, but it never came back up. Right now it's not listening on port 80 or 443 it seems. I also power cycled the box a few times (shutting down & physically removing power for 5 mins), but that didn't seem to help either. Before I did this, it was working fine, so I'm not sure what may have happened?

    Read the article

  • Supermicro SmartOS setup issue with HDDs

    - by Andrew B.
    I'm trying to setup SmartOS on my new Supermicro server (SYS-6027R-N3RF4+). I have 8 HDDs + 2 SSDs installed in the hot-swappable drive bays. I have not configured the Intel RAID controller on the machine (it shows no RAID configured, and lists all 8 HDDs). When I boot SmartOS from my USB key for the first time and get to the initial zpool creation I only see 2 disks listed. How can I tell which two drives are being referenced? How can I get SmartOS to recognize all 8+2 drives? Is there a BIOS setting I need to adjust?

    Read the article

  • Alternate port numbers for Supermicro IPMI View software

    - by MC9000
    I'm using the IPMI View software to manage a SuperMicro server but would like to use alternate port #s within the program itself. In other words - If I use the web browser, it defaults to port 80 - While I can, say change that port to 12345 (or whatever) and type the IP address into the browser (like http://xxx.xxx.xxx.xxx:12345 ) that works just fine. However, in IPMIView, it will assume port 80 and load the browser with the IP (which, naturally, won't work, so I have to manually type in the alternate port #). I can deal with that. The clincher is if I use a port other than 623 for management - (say 55623 for example), the IPMIView will not find it. Same goes for the iKVM port #. Is there some place to specify this (to tell IPMIView to use the alternate port numbers), like a settings file? I'm running this from a Windows client.

    Read the article

  • Using Supermicro IPMI behind a Proxy?

    - by Stefan Lasiewski
    This is a SuperMicro server with a X8DT3 motherboard which contains an On-board IPMI BMC. In this case, the BMC is a Winbond WPCM450). I believe many Dell servers use this a similar BMC model. A common practice with IPMI is to isolated it to a private, non-routable network. In our case all IPMI cards are plugged into a private management LAN at 192.168.1.0/24 which has no route to the outside world. If I plug my laptop into the 192.168.1.0/24 network, I can verify that all IPMI features work as expected, including the remote console. I need to access all of the IPMI features from a different network, over some sort of encrypted connection. I tried SSH port forwarding. This works fine for a few servers, however, we have close to 100 of these servers and maintaining a SSH client configuration to forward 6 ports on 100 servers is impractical. So I thought I would try a SOCKS proxy. This works, but it seems that the Remote Console application does not obey my systemwide proxy settings. I setup a SOCKS proxy. Verbose logging allows me to see network activity, and if ports are being forwarded. ssh -v -D 3333 [email protected] I configure my system to use the SOCKS proxy. I confirm that Java is using the SOCKS proxy settings. The SOCKS proxy is working. I connect to the BMC at http://192.168.1.100/ using my webbrowser. I can log in, view the Server Health, power the machine on or off, etc. Since SSH verbose logging is enabled, I can see the progress. Here's where it get's tricky: I click on the "Launch Console" button which downloads a file called jviewer.jnlp. JNLP files are opened with Java Web Start. A Java window opens. The titlebar says says "Redirection Viewer" in the title bar. There are menus for "Video" "Keyboard" "Mouse", etc. This confirms that Java is able to download the application through the proxy, and start the application. 60 seconds later, the application times out and simply says "Error opening video socket". Here's a screenshot. If this worked, I would see a VNC-style window. My SSH logs show no connection attempts to ports 5900/5901. This suggests that the Java application started the VNC application, but that the VNC application ignores the systemwide proxy settings and is thus unable to connect to the remote host. Java seems to obey my systemwide proxy settings, but this VNC application seems to ignore it. Is there any way for me to force this VNC application to use my systemwide proxy settings?

    Read the article

  • With the Supermicro Embeded BMC, is it possible to connect to Serial Over Lan via SSH?

    - by Stefan Lasiewski
    I have several dozen Supermicro servers which use the Supermicro Embedded BMC. The documentation on that page suggests that I can access the Serial Over LAN (Serial Console) over SSH: SMASH and CLP support SSH based SOL Power control of the server But when I ssh into my BMC, all I see is a Busybox implementation, with no clear ability to connect to the SOL: # ssh 192.168.100.100 -l ADMIN [email protected]'s password: BusyBox v1.1.3 (2011.02.12-01:48+0000) Built-in shell (ash) Enter 'help' for a list of built-in commands. # show -sh: show: not found # smash -sh: smash: not found Supermicro support is giving me inconsistent answers. Is it possible to connect to the SOL via the SSH interface?

    Read the article

  • Supermicro motherboards and systems

    - by jchang
    I used to buy SuperMicro exclusively for my own lab. SuperMicro always had a deep lineup of motherboards with almost every conceivable variation. In particular, they had the maximum memory and IO configuration that is desired for database servers. But from around 2006, I became too lazy to source the additional components necessary to complete the system, and switched to Dell PowerEdge Tower servers. Now, I may reconsider as neither Dell or HP are offering the right combination of PCI-E slots. Nor...(read more)

    Read the article

  • LSI 9285-8e and Supermicro SC837E26-RJBOD1 duplicate enclosure ID and slot numbers

    - by Andy Shinn
    I am working with 2 x Supermicro SC837E26-RJBOD1 chassis connected to a single LSI 9285-8e card in a Supermicro 1U host. There are 28 drives in each chassis for a total of 56 drives in 28 RAID1 mirrors. The problem I am running in to is that there are duplicate slots for the 2 chassis (the slots list twice and only go from 0 to 27). All the drives also show the same enclosure ID (ID 36). However, MegaCLI -encinfo lists the 2 enclosures correctly (ID 36 and ID 65). My question is, why would this happen? Is there an option I am missing to use 2 enclosures effectively? This is blocking me rebuilding a drive that failed in slot 11 since I can only specify enclosure and slot as parameters to replace a drive. When I do this, it picks the wrong slot 11 (device ID 46 instead of device ID 19). Adapter #1 is the LSI 9285-8e, adapter #0 (which I removed due to space limitations) is the onboard LSI. Adapter information: Adapter #1 ============================================================================== Versions ================ Product Name : LSI MegaRAID SAS 9285-8e Serial No : SV12704804 FW Package Build: 23.1.1-0004 Mfg. Data ================ Mfg. Date : 06/30/11 Rework Date : 00/00/00 Revision No : 00A Battery FRU : N/A Image Versions in Flash: ================ BIOS Version : 5.25.00_4.11.05.00_0x05040000 WebBIOS Version : 6.1-20-e_20-Rel Preboot CLI Version: 05.01-04:#%00001 FW Version : 3.140.15-1320 NVDATA Version : 2.1106.03-0051 Boot Block Version : 2.04.00.00-0001 BOOT Version : 06.253.57.219 Pending Images in Flash ================ None PCI Info ================ Vendor Id : 1000 Device Id : 005b SubVendorId : 1000 SubDeviceId : 9285 Host Interface : PCIE ChipRevision : B0 Number of Frontend Port: 0 Device Interface : PCIE Number of Backend Port: 8 Port : Address 0 5003048000ee8e7f 1 5003048000ee8a7f 2 0000000000000000 3 0000000000000000 4 0000000000000000 5 0000000000000000 6 0000000000000000 7 0000000000000000 HW Configuration ================ SAS Address : 500605b0038f9210 BBU : Present Alarm : Present NVRAM : Present Serial Debugger : Present Memory : Present Flash : Present Memory Size : 1024MB TPM : Absent On board Expander: Absent Upgrade Key : Absent Temperature sensor for ROC : Present Temperature sensor for controller : Absent ROC temperature : 70 degree Celcius Settings ================ Current Time : 18:24:36 3/13, 2012 Predictive Fail Poll Interval : 300sec Interrupt Throttle Active Count : 16 Interrupt Throttle Completion : 50us Rebuild Rate : 30% PR Rate : 30% BGI Rate : 30% Check Consistency Rate : 30% Reconstruction Rate : 30% Cache Flush Interval : 4s Max Drives to Spinup at One Time : 2 Delay Among Spinup Groups : 12s Physical Drive Coercion Mode : Disabled Cluster Mode : Disabled Alarm : Enabled Auto Rebuild : Enabled Battery Warning : Enabled Ecc Bucket Size : 15 Ecc Bucket Leak Rate : 1440 Minutes Restore HotSpare on Insertion : Disabled Expose Enclosure Devices : Enabled Maintain PD Fail History : Enabled Host Request Reordering : Enabled Auto Detect BackPlane Enabled : SGPIO/i2c SEP Load Balance Mode : Auto Use FDE Only : No Security Key Assigned : No Security Key Failed : No Security Key Not Backedup : No Default LD PowerSave Policy : Controller Defined Maximum number of direct attached drives to spin up in 1 min : 10 Any Offline VD Cache Preserved : No Allow Boot with Preserved Cache : No Disable Online Controller Reset : No PFK in NVRAM : No Use disk activity for locate : No Capabilities ================ RAID Level Supported : RAID0, RAID1, RAID5, RAID6, RAID00, RAID10, RAID50, RAID60, PRL 11, PRL 11 with spanning, SRL 3 supported, PRL11-RLQ0 DDF layout with no span, PRL11-RLQ0 DDF layout with span Supported Drives : SAS, SATA Allowed Mixing: Mix in Enclosure Allowed Mix of SAS/SATA of HDD type in VD Allowed Status ================ ECC Bucket Count : 0 Limitations ================ Max Arms Per VD : 32 Max Spans Per VD : 8 Max Arrays : 128 Max Number of VDs : 64 Max Parallel Commands : 1008 Max SGE Count : 60 Max Data Transfer Size : 8192 sectors Max Strips PerIO : 42 Max LD per array : 16 Min Strip Size : 8 KB Max Strip Size : 1.0 MB Max Configurable CacheCade Size: 0 GB Current Size of CacheCade : 0 GB Current Size of FW Cache : 887 MB Device Present ================ Virtual Drives : 28 Degraded : 0 Offline : 0 Physical Devices : 59 Disks : 56 Critical Disks : 0 Failed Disks : 0 Supported Adapter Operations ================ Rebuild Rate : Yes CC Rate : Yes BGI Rate : Yes Reconstruct Rate : Yes Patrol Read Rate : Yes Alarm Control : Yes Cluster Support : No BBU : No Spanning : Yes Dedicated Hot Spare : Yes Revertible Hot Spares : Yes Foreign Config Import : Yes Self Diagnostic : Yes Allow Mixed Redundancy on Array : No Global Hot Spares : Yes Deny SCSI Passthrough : No Deny SMP Passthrough : No Deny STP Passthrough : No Support Security : No Snapshot Enabled : No Support the OCE without adding drives : Yes Support PFK : Yes Support PI : No Support Boot Time PFK Change : Yes Disable Online PFK Change : No PFK TrailTime Remaining : 0 days 0 hours Support Shield State : Yes Block SSD Write Disk Cache Change: Yes Supported VD Operations ================ Read Policy : Yes Write Policy : Yes IO Policy : Yes Access Policy : Yes Disk Cache Policy : Yes Reconstruction : Yes Deny Locate : No Deny CC : No Allow Ctrl Encryption: No Enable LDBBM : No Support Breakmirror : No Power Savings : Yes Supported PD Operations ================ Force Online : Yes Force Offline : Yes Force Rebuild : Yes Deny Force Failed : No Deny Force Good/Bad : No Deny Missing Replace : No Deny Clear : No Deny Locate : No Support Temperature : Yes Disable Copyback : No Enable JBOD : No Enable Copyback on SMART : No Enable Copyback to SSD on SMART Error : Yes Enable SSD Patrol Read : No PR Correct Unconfigured Areas : Yes Enable Spin Down of UnConfigured Drives : Yes Disable Spin Down of hot spares : No Spin Down time : 30 T10 Power State : Yes Error Counters ================ Memory Correctable Errors : 0 Memory Uncorrectable Errors : 0 Cluster Information ================ Cluster Permitted : No Cluster Active : No Default Settings ================ Phy Polarity : 0 Phy PolaritySplit : 0 Background Rate : 30 Strip Size : 64kB Flush Time : 4 seconds Write Policy : WB Read Policy : Adaptive Cache When BBU Bad : Disabled Cached IO : No SMART Mode : Mode 6 Alarm Disable : Yes Coercion Mode : None ZCR Config : Unknown Dirty LED Shows Drive Activity : No BIOS Continue on Error : No Spin Down Mode : None Allowed Device Type : SAS/SATA Mix Allow Mix in Enclosure : Yes Allow HDD SAS/SATA Mix in VD : Yes Allow SSD SAS/SATA Mix in VD : No Allow HDD/SSD Mix in VD : No Allow SATA in Cluster : No Max Chained Enclosures : 16 Disable Ctrl-R : Yes Enable Web BIOS : Yes Direct PD Mapping : No BIOS Enumerate VDs : Yes Restore Hot Spare on Insertion : No Expose Enclosure Devices : Yes Maintain PD Fail History : Yes Disable Puncturing : No Zero Based Enclosure Enumeration : No PreBoot CLI Enabled : Yes LED Show Drive Activity : Yes Cluster Disable : Yes SAS Disable : No Auto Detect BackPlane Enable : SGPIO/i2c SEP Use FDE Only : No Enable Led Header : No Delay during POST : 0 EnableCrashDump : No Disable Online Controller Reset : No EnableLDBBM : No Un-Certified Hard Disk Drives : Allow Treat Single span R1E as R10 : No Max LD per array : 16 Power Saving option : Don't Auto spin down Configured Drives Max power savings option is not allowed for LDs. Only T10 power conditions are to be used. Default spin down time in minutes: 30 Enable JBOD : No TTY Log In Flash : No Auto Enhanced Import : No BreakMirror RAID Support : No Disable Join Mirror : No Enable Shield State : Yes Time taken to detect CME : 60s Exit Code: 0x00 Enclosure information: # /opt/MegaRAID/MegaCli/MegaCli64 -encinfo -a1 Number of enclosures on adapter 1 -- 3 Enclosure 0: Device ID : 36 Number of Slots : 28 Number of Power Supplies : 2 Number of Fans : 3 Number of Temperature Sensors : 1 Number of Alarms : 1 Number of SIM Modules : 0 Number of Physical Drives : 28 Status : Normal Position : 1 Connector Name : Port B Enclosure type : SES VendorId is LSI CORP and Product Id is SAS2X36 VendorID and Product ID didnt match FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : 65 Inquiry data : Vendor Identification : LSI CORP Product Identification : SAS2X36 Product Revision Level : 0718 Vendor Specific : x36-55.7.24.1 Number of Voltage Sensors :2 Voltage Sensor :0 Voltage Sensor Status :OK Voltage Value :5020 milli volts Voltage Sensor :1 Voltage Sensor Status :OK Voltage Value :11820 milli volts Number of Power Supplies : 2 Power Supply : 0 Power Supply Status : OK Power Supply : 1 Power Supply Status : OK Number of Fans : 3 Fan : 0 Fan Speed :Low Speed Fan Status : OK Fan : 1 Fan Speed :Low Speed Fan Status : OK Fan : 2 Fan Speed :Low Speed Fan Status : OK Number of Temperature Sensors : 1 Temp Sensor : 0 Temperature : 48 Temperature Sensor Status : OK Number of Chassis : 1 Chassis : 0 Chassis Status : OK Enclosure 1: Device ID : 65 Number of Slots : 28 Number of Power Supplies : 2 Number of Fans : 3 Number of Temperature Sensors : 1 Number of Alarms : 1 Number of SIM Modules : 0 Number of Physical Drives : 28 Status : Normal Position : 1 Connector Name : Port A Enclosure type : SES VendorId is LSI CORP and Product Id is SAS2X36 VendorID and Product ID didnt match FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : 36 Inquiry data : Vendor Identification : LSI CORP Product Identification : SAS2X36 Product Revision Level : 0718 Vendor Specific : x36-55.7.24.1 Number of Voltage Sensors :2 Voltage Sensor :0 Voltage Sensor Status :OK Voltage Value :5020 milli volts Voltage Sensor :1 Voltage Sensor Status :OK Voltage Value :11760 milli volts Number of Power Supplies : 2 Power Supply : 0 Power Supply Status : OK Power Supply : 1 Power Supply Status : OK Number of Fans : 3 Fan : 0 Fan Speed :Low Speed Fan Status : OK Fan : 1 Fan Speed :Low Speed Fan Status : OK Fan : 2 Fan Speed :Low Speed Fan Status : OK Number of Temperature Sensors : 1 Temp Sensor : 0 Temperature : 47 Temperature Sensor Status : OK Number of Chassis : 1 Chassis : 0 Chassis Status : OK Enclosure 2: Device ID : 252 Number of Slots : 8 Number of Power Supplies : 0 Number of Fans : 0 Number of Temperature Sensors : 0 Number of Alarms : 0 Number of SIM Modules : 1 Number of Physical Drives : 0 Status : Normal Position : 1 Connector Name : Unavailable Enclosure type : SGPIO Failed in first Inquiry commnad FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : Unavailable Inquiry data : Vendor Identification : LSI Product Identification : SGPIO Product Revision Level : N/A Vendor Specific : Exit Code: 0x00 Now, notice that each slot 11 device shows an enclosure ID of 36, I think this is where the discrepancy happens. One should be 36. But the other should be on enclosure 65. Drives in slot 11: Enclosure Device ID: 36 Slot Number: 11 Drive's postion: DiskGroup: 5, Span: 0, Arm: 1 Enclosure position: 0 Device Id: 48 WWN: Sequence Number: 11 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SATA Raw Size: 2.728 TB [0x15d50a3b0 Sectors] Non Coerced Size: 2.728 TB [0x15d40a3b0 Sectors] Coerced Size: 2.728 TB [0x15d400000 Sectors] Firmware state: Online, Spun Up Is Commissioned Spare : YES Device Firmware Level: A5C0 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5003048000ee8a53 Connected Port Number: 1(path0) Inquiry Data: MJ1311YNG6YYXAHitachi HDS5C3030ALA630 MEAOA5C0 FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :30C (86.00 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Drive's write cache : Disabled Drive's NCQ setting : Enabled Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No Enclosure Device ID: 36 Slot Number: 11 Drive's postion: DiskGroup: 19, Span: 0, Arm: 1 Enclosure position: 0 Device Id: 19 WWN: Sequence Number: 4 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SATA Raw Size: 2.728 TB [0x15d50a3b0 Sectors] Non Coerced Size: 2.728 TB [0x15d40a3b0 Sectors] Coerced Size: 2.728 TB [0x15d400000 Sectors] Firmware state: Online, Spun Up Is Commissioned Spare : NO Device Firmware Level: A580 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5003048000ee8e53 Connected Port Number: 0(path0) Inquiry Data: MJ1313YNG1VA5CHitachi HDS5C3030ALA630 MEAOA580 FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :30C (86.00 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Drive's write cache : Disabled Drive's NCQ setting : Enabled Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No Update 06/28/12: I finally have some new information about (what we think) the root cause of this problem so I thought I would share. After getting in contact with a very knowledgeable Supermicro tech, they provided us with a tool called Xflash (doesn't appear to be readily available on their FTP). When we gathered some information using this utility, my colleague found something very strange: root@mogile2 test]# ./xflash.dat -i get avail Initializing Interface. Expander: SAS2X36 (SAS2x36) 1) SAS2X36 (SAS2x36) (50030480:00EE917F) (0.0.0.0) 2) SAS2X36 (SAS2x36) (50030480:00E9D67F) (0.0.0.0) 3) SAS2X36 (SAS2x36) (50030480:0112D97F) (0.0.0.0) This lists the connected enclosures. You see the 3 connected (we have since added a 3rd and a 4th which is not yet showing up) with their respective SAS address / WWN (50030480:00EE917F). Now we can use this address to get information on the individual enclosures: [root@mogile2 test]# ./xflash.dat -i 5003048000EE917F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:00EE917F Enclosure Logical Id: 50030480:0000007F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 [root@mogile2 test]# ./xflash.dat -i 5003048000E9D67F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:00E9D67F Enclosure Logical Id: 50030480:0000007F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 [root@mogile2 test]# ./xflash.dat -i 500304800112D97F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:0112D97F Enclosure Logical Id: 50030480:0112D97F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 Did you catch it? The first 2 enclosures logical ID is partially masked out where the 3rd one (which has a correct unique enclosure ID) is not. We pointed this out to Supermicro and were able to confirm that this address is supposed to be set during manufacturing and there was a problem with a certain batch of these enclosures where the logical ID was not set. We believe that the RAID controller is determining the ID based on the logical ID and since our first 2 enclosures have the same logical ID, they get the same enclosure ID. We also confirmed that 0000007F is the default which comes from LSI as an ID. The next pointer that helps confirm this could be a manufacturing problem with a run of JBODs is the fact that all 6 of the enclosures that have this problem begin with 00E. I believe that between 00E8 and 00EE Supermicro forgot to program the logical IDs correctly and neglected to recall or fix the problem post production. Fortunately for us, there is a tool to manage the WWN and logical ID of the devices from Supermicro: ftp://ftp.supermicro.com/utility/ExpanderXtools_Lite/. Our next step is to schedule a shutdown of these JBODs (after data migration) and reprogram the logical ID and see if it solves the problem. Update 06/28/12 #2: I just discovered this FAQ at Supermicro while Google searching for "lsi 0000007f": http://www.supermicro.com/support/faqs/faq.cfm?faq=11805. I still don't understand why, in the last several times we contacted Supermicro, they would have never directed us to this article :\

    Read the article

  • Supermicro IPMI on MBD-X8DAH+-F-O motherboard. Keyboard and mouse do not work after booting Windows Server 2008 R2

    - by LDelgado
    Hell Everyone, I built a server with the mentioned motherboard. I installed Windows Server 2008 R2 Enterprise on this server. IPMI is integrated on the motherboard with its own dedicated NIC. I've got that NIC configured with its own IP address. I can remote into it using IPMI, and I can remotely control the server settings before booting the OS ( BIOS, RAID configuration, etc). When the OS boots, I lose the mouse and keyboard. I cannot use the keyboard or mouse when installing the OS either. So the Keyboard and Mouse only work when no OS is loaded. Once the OS loads I lose it - that is my problem. I've been doing some research and trying a few things, but I have not been successful in fixing this issue. I may be wrong, but based on the things I've found online, it seems that the problem could be caused by the way the OS handles USB. The server is headless. There is no keyboard, mouse, or monitor plugged into it. When I boot up the OS and remote into it, I cannot see a mouse or keyboard listed in the Device Manager. Based on what I've read, it seems that the OS should detect a mouse and a keyboard when connecting remotely via IPMI. The following are the solutions I've tried. Nothing has worked so far: I've updated the firmware of the IPMI component to the latest firmware - 1.33. I made sure that the mouse mode was set to Absolute (Windows OS). I've loaded the factory defaults several times. I've enabled Port64h/60h Emulation under the USB settings in the BIOS. I've disabled USB legacy support in the BIOS. I made sure the firewall wasn't blocking IPMI (disabled the firewall). And that's about it. I've found threads in some forums from people having the same issue as me, but they were not running the same OS. They were either running Linux or FreeBSD. Most of them fixed their problem by selecting the right mouse mode (Linux in their case). There was one other that solved the problem by disabling USB Mass Storage mode. He stated "When I set it to disable USB Mass Storage when no image is loaded, the ukbd came alive, and I'm typing this on the IPMI Console. " source: http://freebsd.1045724.n5.nabble.com/IPMI-Console-No-luck-once-OS-is-booted-td3967868.html I suspect the solution described in the previous paragraph is somehow related to my problem. I've found several threads on the internet with issues describing the same problem, but none of them were with Windows Server 2008 R2. Again, I may be wrong, but it seems like that could be the issue. I just don't know how I go about applying a solution in Windows Server 2008 R2. In any case, I could use your expertise. Maybe I am missing something, or maybe I'm on the right track. Your help is much appreciated. Thank you in advance,

    Read the article

  • supermicro server ipmi problem - problem with keyboard layout

    - by maxs
    hi, we hava a supermicro server (x8dtl-if-O with suse 11): if i connect from my workstation (xppro-german)with the remote console i can not type any öä<... (on the server local - we have no problems - only remote). the keyboard layout of the workstation is german - if i switch the keyboard layout to english i can type öäü.... - but i don't can type <| ?? thx

    Read the article

  • Supermicro MBD-X9DRL-IF-B and 8 X Hynix 4Gb DDR3 ECC dont boot

    - by Avi Keinan
    I have a custom build server with 2 Xeon E5-2609 and Supermicro MBD-X9DRL-IF-B. Right now the server has 4X Hynix 4Gb 2Rx8 PC3L-10600R-9-10-B0 HMT351R7BFR8A. and its working great. We baught another 4 from the same series of memory, when we installed all the ram (4 sticks already installed and we added 4 new sticks) the server didn't boot. When we replaced the current memory with the new memory - the server did boot. Right now we are in a problem because we need to extend this server ram but the motherboard don't run with 8X4Gb. Any ideas why? I have attached a picture with one of the current memory stick and one of the new memory stick. Thanks in advence.

    Read the article

  • dmidecode showing less Memory Capacity than Motherboard spec?

    - by starchx
    We got a supermicro server, http://www.supermicro.com/products/system/1u/5016/sys-5016i-ur.cfm, according spec, the server supports up to 32G memory when using ECC Register Memory. However, when I tried the dmidecode command, it says 24G max memory: [root@c1 ~]# dmidecode | grep Maximum Maximum Size: 256 kB Maximum Size: 1024 kB Maximum Size: 8192 kB Maximum Memory Module Size: 4096 MB Maximum Total Memory Size: 24576 MB Maximum Capacity: 24 GB Maximum Value: Unknown Which one I should trust?

    Read the article

  • Supermicro X8SIL-F with Enermax Modu82+ 625W PSU booting issue

    - by Richard Whitman
    I am assembling a custom PC. The configuration is below: Motherboard: Supermicro X8SIL-F Processor: Intel Xeon 3430 Power Supply: Enermax Modu82+ 625W. Memory: Kingston KVR1333D3LQ8R9S/8GEC 8GBx1 installed in DimmA1 This power switch: Frozen CPU switch When I turn on the PSU, the motherboard tries to start itself before I even push the power switch. The following happens: The CPU fan rotates like once or twice, and then stops. After 1-2 seconds, the CPU fan tries to rotate again and stops after about one or two rotations. Finally, after another 1-2 seconds, it again starts and this time it rotates for about 3-4 seconds before stopping. If I pull out the Power switch, and turn on the PSU, again the MB turns on itself and the following happens: The CPU fan rotates like once or twice, and then stops. After 1-2 seconds, the CPU fan tries to rotate again and stops after about one or two rotations. Finally, after another 1-2 seconds, it again starts and the system boots properly I am sure there is nothing wrong with any of the components, because I have two sets of identical components (2 MBs, 2 CPUs, 2 PSUs, 2 switches and so on). And both of the systems show the same symptoms. Why is the MB booting up by itself? Why does it fail to boot when the Power Switch is installed? Is something wrong with the type of Power Switch I am using? PS: the power switch is installed correctly, I have double checked the MB manual to make sure its connecting the right pins.

    Read the article

  • ESXI 4 IPMI 2.0 - Cannot connect to IPMI after boot past bios

    - by adamflavell
    Dear All, I would appreciate any help here. I have a Supermicro 6016T-NTRF running ESXI 4 fine. The health monitors are showing up so ESXI is picking up the IPMI status. But I cannot connect to the host remotely via the dedicated IPMI nic. When the machine is in bios section I CAN connect but as soon as ESXI starts to boot I get blocked. Supermicro say the issue must be that ESXI is blocking the IPMI ports. How can this be corrected? I have read that there is no firewall on ESXI 4. Thanks, Adam

    Read the article

  • Server reboots every 4.5-5.5 minutes...

    - by Andy
    Hi, I've recently installed a server in colocation, and my server is rebooting every 4.5-5.5 minutes. Regardless of the OS I run, it reboots. I have all ECC memory in the server, so it should correct errors if there is a bad bit in the memory, right? It's weird because it always happens about 4.5-5.5 minutes after bootup. My motherboard is a Supermicro X8DTL-iF. I read on a blog that another person had the problem, and supermicro recommended to do a BIOS update. Is this the right course of action?

    Read the article

  • SuperMicro BMC on OpenSuSE Linux --cannot access from LAN

    - by Kendall
    Hi, I have an (old) SMC-001 IPMI device on an (old) X6DVL-EG2 motherboard. My problem is that I cannot access the BMC from LAN. I'm also getting some interesting output from ipmitool. First, the setup. I enable Console Redirection in the BIOS, turn BIOS Redirection after POSt to "disabled". I then modprobe'ed for ipmi_msghandler, ipmi_devintf and ipmi_si. I then found ipmi0 under /dev. So far so good. Since I want console redirection over serial, I modified /boot/grub/menu.lst: http://pastebin.com/YYJmhusQ I then modified "/etc/inittab" as follows: S1:12345:respawn:/sbin/agetty -L 19200 ttyS1 ansi Networking I set as following, using "ipmitool" ipaddr: 192.168.3.164 netmask: 255.255.255.0 defgw: 192.168.3.1 The above are correct for my environment. To test it I do: ipmitool -I open chassis power off which responds by powering off the machine. When I to access from another computer on the network, however, I get an error message: host# ipmitool -I lanplus -H 192.168.10.164 -U Admin -a chassis power status Error: Unable to establish LAN session Unable to get Chassis Power Status "Admin" seems to be a valid user name: host# ipmitool -I open user list 1 2 Admin true false true USER The interesting output from ipmitool I initially mentioned: host # ipmitool -I open lan set 1 access on Set Channel Access for channel 1 failed: Request data field length limit exceeded Also, newload4:/home/gjones # ipmitool channel info 1 Channel 0x1 info: Channel Medium Type : 802.3 LAN Channel Protocol Type : IPMB-1.0 Session Support : session-less Active Session Count : 0 Protocol Vendor ID : 7154 Get Channel Access (volatile) failed: Request data field length limit exceeded The output of "ipmitool -I open lan print 1" is here: http://pastebin.com/UZyL6yyE Any help/suggestions is greatly appreciated; I've been working with this thing for a few hours now with no success.

    Read the article

  • HT Link Sync Error after Ubuntu 10.04 LTS Installation

    - by marklab
    Update 1 I just assembled an exact replica of this server, and successfully installed Ubuntu 10.04 LTS in a RAID10 configuration. The success was confirmed by a login to the initial account. There must be a hardware component that is faulty. Since the error mentions HT, which I believe to be Hyper Threading, I will start with the CPUs. Please indicate if this error is more strongly associated with any other piece of hardware. Or make a recommendation of another approach that would be good for this issue. Issue I was attempting to install Ubuntu 10.04 LTS on this system with the board RAID10 configured. However, the installation failed at the partitioning stage by rebooting the system. Upon reboot, there is an error report after POST listing the following: Node0: NB WatchDog Timer Error Node1: HT Link Sync Error Node2: HT Link Sync Error ... Node7: HT Link Sync Error Press F1 to continue/resume. After pressing F1 the system will boot from the Ubuntu 10.04 LTS installation disc. However, it will fail at the same stage, and go through the same process from there. Hardware CPU: AMD OPTERON X12 6172 G34 2.1G 18MB Motherboard: Supermicro H8QG6-F HDD: WD Caviar Green 2TB 5.4K RPM Troubleshooting I disabled RAID10 on the system, and installed the Ubuntu on a single drive. It installed successfully. I then went back to a RAID10 setup and attempted to install on the system again, and was able to make it through the partitioning stage. However, upon reboot, the system reported: Error: file not found, and then booted me into the Grub Rescue console. I feel I have aggravated the problem at this point because when I attempted to install from the boot disc again, the system reboots upon hitting enter to even start the installation process. It does the same thing when trying to boot from an Ubuntu 11 disc. I have not been able to find any information on this HT Link Sync Error, which I feel may have started the problems I am experiencing now with the installation of the OS. I am also aware that Ubuntu is said not to be supported by the motherboard according to Supermicro's site. However, since I was able to install it successfully on a single drive, I do not believe it is incompatible. I would like to know a reason for why it's failing to install on/off.

    Read the article

  • How can I tell which interface my Supemicro IPMI is piggybacking on?

    - by lorin
    I've used IPMI before, but only on servers where the IPMI interface had a dedicated ethernet port. I've got an Ubuntu 10.04 server with two ethernet cards, which is supposed to have an IPMI interface on it (the motherboard is a Supermicro H8DMR-I2). From what I understand, the IPMI interface is piggybacking on one of the two NICs. Is there any way I can tell which NIC the IPMI interface is piggybacking on? Using ipmitool I've tried to set the IP address on the IPMI interface for the subnet for eth0, and then the subnet for eth1, and it's never reachable. (Can you even reach an IPMI interface from the same NIC it's piggybacking off of, or do you need to try connecting from a different machine on the network?) Also, is there anything special I need to do to enable it? I can access the IPMI interface locally using "ipmitool".

    Read the article

  • Small web server hardware advice

    - by Dmitri
    We need to build a new web server for our organization. We have around 100 hundred small traffic web sites, so our hardware requirements are not too tough. We run CentOS 6, Varnish+Apache, PHP, MySQL, Typo3 CMS for most of websites. Here's a hardware we want to buy: SuperMicro X9SCA-F-O (we need to have a remote management capability) (or better X9SCM-F?) Intel Xeon E3-1220 v2 2*4Gb DDR-III 1600MHz Kingston ECC (KVR16E11/4) (currently we have 4gb, and it feels like enough, so no reason for 16gb yet). Procase EB140-B-0 (1 unit) PSU 350W Procase MG1350, Active PFC We already have: Intel 335 120GB SSD (for OS, databases and important websites). 2*2tb WD Green RAID1 (for other data and backups). Does it look like a reasonable choice for our needs? Any issues with hardware compatibility? Any other notes?

    Read the article

  • Create XFS volume on /dev/sg* device

    - by cpt.Buggy
    Now I have couple of Supermicro 24x2Tb SATA servers and I have now idea how to get access to disks. I need to create XFS volume on each of them but really don't know how to do it, because fdisk doesn't see them. # sg_scan -i /dev/sg0: scsi0 channel=0 id=0 lun=0 [em] ATA ST3250318AS CC38 [rmb=0 cmdq=0 pqual=0 pdev=0x0] /dev/sg1: scsi1 channel=0 id=0 lun=0 [em] ATA ST3250318AS CC38 [rmb=0 cmdq=0 pqual=0 pdev=0x0] /dev/sg2: scsi6 channel=1 id=8 lun=0 [em] Hitachi HDS722020ALA330 JKAO [rmb=0 cmdq=1 pqual=1 pdev=0x0] ... ... ... /dev/sg25: scsi6 channel=1 id=31 lun=0 [em] Hitachi HDS722020ALA330 JKAO [rmb=0 cmdq=1 pqual=1 pdev=0x0] /dev/sg26: scsi6 channel=3 id=0 lun=0 [em] LSILOGIC SASX36 A.1 7017 [rmb=0 cmdq=1 pqual=0 pdev=0xd] # sg_map /dev/sg0 /dev/sda /dev/sg1 /dev/sdb /dev/sg2 .. ... ... /dev/sg25 /dev/sg26 I can't use fdisk and mkfs, what should I do?

    Read the article

  • 4TB HGST SATA drive only shows 1.62 TB in Windows Server 2012

    - by user136085
    I'm using a Supermicro X9SRE-3F motherboard with the latest BIOS and 2x 4TB drives connected to the on-board SATA controller. If I set the BIOS to RAID and create a RAID 1 array, the array shows up in the BIOS as 3.6TB. However when I boot Windows (on a separate RAID 1 array), the 4TB drives show up individually in disk manager as 2x 1.62TB drives. I could use Windows 2012 to set up software RAID 1, but when I set the BIOS back to 2x individual drives, they still show up in Windows as 2x 1.62TB drives. How do I access the full capacity of these drives? Thanks, Brian Bulaw

    Read the article

  • Motherboard rejects identical hard drive, one works the other doesn't

    - by Payson Welch
    I have an interesting situation. I have a Dell XS23-SB server that has four blades in it. The blades use Supermicro X7DWT motherboards, and interface with the sata drives through a backplane. I took two identical drives from a raid 0 enclosure that came from the factory (GDrive), one works on all four servers, the other does not. I verified that they both work by plugging them into a hard drive cradle. This behavior can be repeated with other drives, some drives work and some don't. However when i test them, they ALL work on my PC. What could cause this?

    Read the article

  • SYS-5016T-MTFB will not POST without manual assistance (Motherboard: X8STi-F)

    - by Dan
    I have a Supermicro 5016T-MTFB 1U server which I am in the process of setting up, but it has a really strange problem. When the system is powered on it will not POST until I press the reset button a few times, followed by pressing the delete key on the keyboard to "wake it up". If I power it on and do nothing, the fans spin up but nothing else happens at all. After pressing the reset button once, the red "overheat" light comes on and blinks which is supposed to indicate a fan failure - but all the fans are working. Pressing reset again usually stops the blinking, and the system starts the normal POST routine but it will not actually get to the bios screen unless I press delete. If I don't press delete, it just continues to hang. After pressing delete it will take me into the bios setup screen, if I exit without saving changes I can boot the system normally. I was able to successfully install Linux with no trouble...but upon rebooting the same problem happened again. This board has integrated IPMI which I thought was the problem, so I disabled it via the jumper on the board. Did not help. Each time this system powers on, it goes on for a second, then turns off again for another second, then turns back on again. I don't know why it does that. Here is what I put in the system: 1 x Xeon E5630 (Nehalem) 80W TDP (it's not overheating, CPU temps stay under 40 degrees C) 2 x Kingston 2GB x 3 DDR3-1066 Memory ECC, unbuffered, unregistered (kvr1066d3e7sk3/6g) 1 x Intel X25-M 160 GB 2 x Western Digital RE3 1TB

    Read the article