Search Results

Search found 196 results on 8 pages for 'wiring'.

Page 1/8 | 1 2 3 4 5 6 7 8  | Next Page >

  • Home CAT6 wiring: CMR vs CMP?

    - by Eddie Parker
    I'm planning on wiring my house with CAT6 cable. I'm finding a large jump in price between CMR and CMP cabling, and I'm confused by what counts as a 'plenum' and what does not. As I'm wiring my house, I'm planning on going through interior (hollow) walls, and through the attic and crawlspace to get to the points I wish to wire. I will be going between floors at one point, which leads me to believe I need at least CMR, and obviously CMP wouldn't hurt either. I don't mind spending the extra money if I need to, but is it overkill going for CMP if the bulk of the wires are either going vertical, or through a crawlspace or attic?

    Read the article

  • Motherboard Wiring

    - by JT
    HI All, I bought a new case to put a motherboard in. Everything fits, I have done this before, but not in a long time! The case has wires for - Power SW - Reset SW - Power LED - HDD LED On the motherboard (ASUS M2NPV-VM) it is clearly labeled where these go, but I cannot remember where the black wire for each goes versus the colored wire? I don't want to put it backwards, wont I blow the motherboard?

    Read the article

  • What am I doing wrong with this cat 6 patch panel wiring?

    - by Max Hodges
    top number is transmitter bottom number is remote terminator 12345678 36145278 is this because I could be mixing T568A and T568B wiring? how do I know if my patch cord is A or B? Do I just look at the plug and match it up with the diagram on the back of the panel somehow? EDIT I read that 36145278 indicates a cross over cable, but I'm not trying to make a cross over. Where did I go wrong? I'm guessing the cable plug is T568A but I wired it to the panel using T568B. So I need to redo it as T568A. But in the future how do I know if I cable is A or B? Cheers!

    Read the article

  • convert home phone wiring to Ethernet

    - by aaa
    can i convert phone wiring in walls to act as only Ethernet network cause the phone wiring is not in use and not connected to the phone company so there is no voltage in the wires i remove the wall plate and i find 6 wires blue,blue/white,green,green/white,orange,orange/white , and i know that Ethernet use 8 here is what i am thinking get Ethernet cable cut it in half and attach wires from wall to the first computer and the same with the other computer so if this is possible do i just attach wires in the same color and ignore brown wire or do i have to rearrange wires , and how much the speed will be thank you in advance

    Read the article

  • convert home phone wiring to Ethernet

    - by aaa
    can i convert phone wiring in walls to act as only Ethernet network cause the phone wiring is not in use and not connected to the phone company so there is no voltage in the wires i remove the wall plate and i find 6 wires blue,blue/white,green,green/white,orange,orange/white , and i know that Ethernet use 8 here is what i am thinking get Ethernet cable cut it in half and attach wires from wall to the first computer and the same with the other computer so if this is possible do i just attach wires in the same color and ignore brown wire or do i have to rearrange wires , and how much the speed will be thank you in advance

    Read the article

  • Using pre-made patch cables on a punch down block?

    - by Trevor Harrison
    I need to add a 24 port switch to my wiring closet. In the (distant) past, I usually just punched each port of the switch to a 110 block on the wall (using hand-made cables), and cross connect between that and the 110 block that has the runs to each workstation. To save time, I'm thinking of buying 12 pre-made drop cables, cutting them in half (so 24 single ended cables), and punching those to my 110 block. The things I'm worried about are wire type (ie. solid vs. strands) and color scheme. I really don't know if they use different wire types (still?), but I remember that being an issue at one point. Can anyone comment on this? (I definitely won't feel comfortable trying to punch stranded wiring on my 110 block) Also, picking up a random pre-built cable I had laying around, I noticed that the color scheme used didn't appear to be T568B, but T568A, which would clash with the rest of my wall. Anyone know of an online source that specifies these things? I've looked at www.cablesforless.com (which does have nicer prices) and www.cablestogo.com (which seem stupid expensive) so far. Cables For Less doesn't specify wiring scheme, Cables To Go does specify T568B. Both seem to specify stranded wires instead of solid.

    Read the article

  • Wiring my internet

    - by u8sand
    I have Verizon internet service and am currently using wifi. My router is in the basement and my desktop computer is 2 floors and on the other side of the house above it... Worst possible positioning but that's just how things worked out. My wireless currently is extremely unstable so I've decide to correct the problem by wiring my computer directly. The problem lies here: when redoing the room next to it (when the wall was open) we went ahead and wired some coaxial cable from our attic to our basement (with plenty of slack on both ends, don't ask me why we didn't go ahead and wire a CAT6 cable). The question is: Can I use the coaxial cable to bring me internet connection? Naturally the router (which needs to stay where it is) takes a coaxial cable input and has Ethernet outputs. So maybe I would have to take a ethernet cable, convert to coaxial-coaxial to my computer, convert back to ethernet. Is this even possible to convert from coaxial to ethernet? Or do I have to attempt to go ahead and fish a cat6 cable through my house. I cannot just split the signal because that would require two routers and two networks (which I don't believe would work with one cable-one ISP correct me if I'm wrong). Thanks

    Read the article

  • Is a low voltage licence needed to install network cable?

    - by BCS
    In some places in the US you need a "low voltage licence" to install "low voltage wiring" but I can't seem to find anything that says if this includes network wiring. (I know this will differ from place to place so please state where you are referring to.) Does the law say you need a licence? Does anyone pay attention to it? Are their any exception you known of? How sure are you of your information? Got any links? "Me specific" parts of the question. p.s. I'm looking for info on Idaho, USA but answerers for anywhere welcome. edit: I have some formal training in this and am completely confident that I can do it safely and correctly. However the training was pre-2008 befor Idaho switched to the national building code.

    Read the article

  • Wiring up JavaScript handlers after a Partial Postback in ASP.NET

    - by Richard
    I am trying to use LinkButtons with the DefaultButton property of the ASP.NET Panel in an UpdatePanel. I have read and used the various other answers that are around describing the wiring up of the click event so that a full postback is not done instead of a partial postback. When the page loads, I wire up the .click function of the LinkButton so that the DefaultButton property of the ASP.NET panel will work. This all works fine, until you bring an UpdatePanel into the mix. With an UpdatePanel, if there is a partial postback, the script to wire up the .click function is not called in the partial postback, and hitting enter reverts to causing a full submit of the form rather than triggering the LinkButton. How can I cause javascript to be executed after a partial postback to re-wire up the .click function of the LinkButton? I have produced a sample page which shows the problem. There are two alerts showing 1) When the code to hook up the .click function is being called, and 2) When the .click function has been called (this only happens when you hit enter in the textbox after the event has been wired up). To test this code, type something in the textbox and hit Enter. The text will be copied to the label control, but "Wiring up Event Click" alert will not be shown. Add another letter, hit enter again, and you'll get a full postback without the text being copied to the label control (as the LinkButton wasn't called). Because that was a full postback, the Wiring Up Event Click event will be called again, and the form will work properly the next time again. This is being done with ASP.NET 3.5. Test Case Code: <%@ Page Language="C#" Inherits="System.Web.UI.Page" Theme="" EnableTheming="false" AutoEventWireup="true" %> <script runat="server"> void cmdComplete_Click(object sender, EventArgs e) { lblOutput.Text = "Complete Pressed: " + txtInput.Text; } void cmdFirstButton_Click(object sender, EventArgs e) { lblOutput.Text = "First Button Pressed"; } protected override void OnLoad(EventArgs e) { HookupButton(cmdComplete); } void HookupButton(LinkButton button) { // Use the click event of the LinkButton to trigger the postback (this is used by the .click code below) button.OnClientClick = Page.ClientScript.GetPostBackEventReference(button, String.Empty); // Wire up the .click event of the button to call the onclick function, and prevent a form submit string clickString = string.Format(@" alert('Wiring up click event'); document.getElementById('{0}').click = function() {{ alert('Default button pressed'); document.getElementById('{0}').onclick(); }};", button.ClientID, Page.ClientScript.GetPostBackEventReference(button, "")); Page.ClientScript.RegisterStartupScript(button.GetType(), "click_hookup_" + button.ClientID, clickString, true); } </script> <!DOCTYPE html PUBLIC "-//W3C//DTD XHTML 1.0 Transitional//EN" "http://www.w3.org/TR/xhtml1/DTD/xhtml1-transitional.dtd"> <html> <head> <title>DefaultButton/LinkButton Testing</title> <style type="text/css"> a.Button { line-height: 2em; padding: 5px; border: solid 1px #CCC; background-color: #EEE; } </style> </head> <body> <h1> DefaultButton/LinkButton Testing</h1> <form runat="server"> <asp:ScriptManager runat="server" /> <asp:UpdatePanel ID="UpdatePanel1" runat="server"> <ContentTemplate> <div style="position: relative"> <fieldset> <legend>Output</legend> <asp:Label runat="server" ID="lblOutput" /> </fieldset> <asp:Button runat="server" Text="First Button" ID="cmdFirstButton" OnClick="cmdFirstButton_Click" UseSubmitBehavior="false" /> <asp:Panel ID="Panel1" runat="server" DefaultButton="cmdComplete"> <label> Enter Text:</label> <asp:TextBox runat="server" ID="txtInput" /> <asp:LinkButton runat="server" CssClass="Button" ID="cmdComplete" OnClick="cmdComplete_Click" Text="Complete" /> </asp:Panel> </div> </ContentTemplate> </asp:UpdatePanel> <asp:Button runat="server" ID="cmdFullPostback" Text="Full Postback" /> </form> </body> </html>

    Read the article

  • "Modern" Ethernet over coax

    - by Electrons_Ahoy
    So, I've just bought a house. It's reasonably new - built in the early '00s. One of the features that got built in was a cable TV drop in every room. The cabling is gorgeous - there's even a wiring cabinet of sorts in a closet where the cables all tie together to the splitter to the outside line. Of course, my problem is that I only own the one TV. I do, however, own a few computers. What I would love to be able to do is drop a switch in the wiring closet and run 100/1000BASE-T ethernet over the coax in the walls I wouldn't otherwise be using. My fantasy would be if you could get some kind of adapter-plug-thing that would take a coax plug on one side and a cat5/RJ45 plug on the other. Had anyone else done this? Any suggestions? (There are a few other options that suggest themselves - first, I could just use the existing cabling channels and re-run cat5 or 6 through the walls. While tempting, that sounds like more work than I really want to put in, so I'm calling that Plan B. Also, I could just scare up a mess of old 10BASE2 cards and run the house on thinnet, all mid-90s style. While I think I'd get major style points for that, I don't think I can get a 10BASE2 adapter for the new laptop. Also, I have all these super-snazzy gigabit adaptors I'd like to be using. And so forth.)

    Read the article

  • Network corruption - corrupt downloads, corrupt streams, etc.

    - by rfrankel
    I've been having some problems with my home LAN. Downloaded executables won't run, my remote desktop sessions keep getting interrupted due to encryption errors, flash video streams show visible corruption (both Hulu and YouTube), and I've had a couple downloads for which the md5 hashes don't match. The problem has even occurred with a couple images embedded in webpages, though that's rare enough (presumably because images are relatively smaller files). I've had this problem across two Windows machines and a Mac, so it's neither machine-specific nor at the app or OS level. Comcast claims it's nothing to do with them, and my Linksys/Cisco RV016 router is out of warranty, so I have no access to official support. When I log into my router, it shows no error packets or dropped packets received. I plugged a laptop directly into the router and was able to download a 5.5 MB file and verify its MD5 hash, which is not proof that the problem is downstream of the router, but makes it seem quite likely, since I failed to download the same file several times from two desktops (one Mac, one Windows). Could this be a wiring problem? If so, is there any way clever/elegant to determine which wiring is faulty with just software? If I can avoid tracing all the wires throughout my entire house it would make my life quite a bit easier.

    Read the article

  • Motherboard wiring

    - by ML
    I am putting a new motherboard in a chenbro chasis and I dont get how to plugin the wires for powerSW resetSW, etc. It is a SuperMicro P4DP6 motherboard. ** I cant post an image yet, but here is a long to the spot on the mobo where this goes: http://andrewslack.info/mobo.png The powerSW lead is a green and white wire. I have the wire for PowerSW in place as the white wire ground and I have tried the reverse even (green to ground). The wire is covering Pin 1 and 2 in the diagram And I press the power button on the machine and nothing happens. It worked before I replaced the motherboard, the 24-pin ATX power leas is connected as well as the 2dn 6-pin optional power. Thoughts?

    Read the article

  • Motherboard wiring

    - by ML
    I am putting a new motherboard in a chenbro chasis and I dont get how to plugin the wires for powerSW resetSW, etc. It is a SuperMicro P4DP6 motherboard. ** I cant post an image yet, but here is a long to the spot on the mobo where this goes: http://andrewslack.info/mobo.png The powerSW lead is a green and white wire. I have the wire for PowerSW in place as the white wire ground and I have tried the reverse even (green to ground). The wire is covering Pin 1 and 2 in the diagram And I press the power button on the machine and nothing happens. It worked before I replaced the motherboard, the 24-pin ATX power leas is connected as well as the 2dn 6-pin optional power. Thoughts?

    Read the article

  • How to test/debug bad network wiring?

    - by Jack Lloyd
    I recently bought a place already wired with Cat 5E (8 ports, leading to a central closet). However attempting to get link, nothing works. On closer examination, it was obvious that the ends in the closet were wired backwards (brown on pin 1, etc). The jacks that I've pulled out of the wall do look to be correctly done. However, testing with a network cable tester shows zero link between any of the jacks and any of the ports in the closet - I had expected to just see a 1/8, 2/7, ... 8/1 mismatch, but instead get nothing at all. The runs are accessible and look neat, though they take some bends that seem quite sharp and are in some cases much longer than they need to be (the person who put this in was a professional electrician but I suspect this was the first time he ran network cabling). My best guess at this point is that he either bought bad cable, or put so much tension on it that he snapped wires. Though it seems surprising/unlikely that I wouldn't get at least one active wire on one of the 8 lines. So, my question: is there anything else I should try or test before I go ripping out everything and running new cable?

    Read the article

  • Cat5 wiring in my home [closed]

    - by Mike
    I have problem with cat5 cabling First I ran a length of cable 30 metres to my bedroom 1 and and connected both ends to a wall sockets internally using my punch down tool, both ends look fine. I also ran a cable from bedroom 1 to bedroom 2 so my son can use same internet connection , i then parallel connected my cables in bedroom 1 against using punch down tool using same colours all the way through. I ran a Ethernet cable from modem to first wall socket close to it then at bedroom end used another Ethernet cable to connect pc, it wouldn't connect to pc so I disconnected bedroom 2 cable from bedroom 1 socket. I connected bedroom 1 to pc and it worked, but how do I connect bedroom 2 (obviously cat 5 cable bedroom 1 to 2 is in place) As soon as I connect one wire from bedroom2 I loose Internet connection!

    Read the article

  • House Wiring for Ethernet/Coax/Power

    - by Adam Kragt
    Hoping this is the right place to post, the rest didn't seem to fit. If not, I apologize. Remodeling my house and want to wire up each room with Ethernet/coax wall ports. Both Ethernet, coax and power will be running through the sub-floor. I've read that there needs to be 2 ft between power cables and Ethernet to limit/prevent interference. Is this true? If not, does anyone know what the distance is? Thanks!

    Read the article

  • Auto wiring of Property does not work for me

    - by Xabatcha
    Hi All, In my Asp.Net project I wanna use Property Auto-wiring, e.g. for my ILogger. Basically I placed Property into my base classes. One for Page, one for UserControl. Like below. public class UserControlBase : UserControl { public ILogger CLogger { get; set; } .... } However when calling in inherited control, logger is null. I checked the container and it'a definitely set. Below is setting which is called from Global.asax. public static void SetupForIoC() { Debug.WriteLine("SetupForIoC"); ObjectFactory.Initialize(x => { x.FillAllPropertiesOfType<ILogger>().TheDefaultIsConcreteType<EntLibLogger>().AsSingletons(); x.FillAllPropertiesOfType<ISiteService>().TheDefaultIsConcreteType<SiteService>().AsSingletons(); }); Debug.WriteLine(ObjectFactory.WhatDoIHave()); } Thanks for any advice, tip? X.

    Read the article

  • RJ45 female to male fault

    - by GeoPhoenix
    i have the following - common - problem, on one end of the cable, there are RJ45 males T586 A which are connected to a 8-port switcher, on the other end, there supposed to be RJ45 females _T586 A which in turn will allow another RJ45 male to be connected. the commonly used color scheme was followed on males (having the head down) blue white blue orange white green green white orange brown white brown the problem i believe is located on female end of cable, which i try multiple time to follow the numbers designated by the module, which is the list above in reverse, and as listed resulting in no signal transmission. tried the T586B (both ends) for device to device once, but no results. Which is the proper way of handling this wiring? There were also additional RJ45 females with the numbers 6-5-4-3, but 1 to 8 isn't supposed to be used for this?

    Read the article

  • Home Networking Questions

    - by Eddie Parker
    Hello: I'm looking to wire my home with CAT-X (where X is probably going to be CAT-6, unless someone can convince me differently. ;) ). I'm seeking advice on what equipment I'll need for the job, and any things I should watch out for. It's a two story half-duplex I'll be wiring, roughly about 1800 sq ft. Here's what I believe I need so far: Bulk CAT-6 Ethernet cabling CM Rated Gigabit switch(es?) Patch panel Equipment for cutting, terminating wire, fishing through walls, etc Wall outlet covers, etc. Questions I have: Does it matter the MHz rating on the Ethernet cable? If so, why? I have two gigabit switches currently, an 8-port and a 5-port. Should I buy one massive switch to cover all the connections I need, or should I just chain the two together and buy a switch for however many other connections I need? Do I really need a patch panel? I understand it keeps the cables looking cleaner than coming out of a hole in the wall, but is there some other product I can use, perhaps combining a switch with a patch panel or some such? Ideally I'll have all this running out of a relatively small closet, so the less components (or smaller) the better. Any advice, links, or suggested product to use/avoid would be appreciated!

    Read the article

  • StructureMap: Wiring (generic) implementations to an implementation of another type

    - by Jeremy Frey
    If I have an interface: public interface IRepository<T> And an abstract class: public abstract class LinqToSqlRepository<T, TContext> : IRepository<T> where T : class where TContext : DataContext And a whole bunch of implementations of IRepository / LinqToSqlRepository (e.g. AccountRepository, ContactRepository, etc.), what's the best way to to use StructureMap (2.5.3) to generically wire them all up? e.g., I want this code to pass: [Test] public void ShouldWireUpAccountRepositories { var accountRepo = ObjectFactory.GetInstance<IRepository<Account>>(); Assert.IsInstanceOf<AccountRepository>(accountRepo); } Without explicitly writing this: ObjectFactory.Configure(x => x.ForRequestedType<IRepository<Account>>() .TheDefaultIsConcreteType<AccountRepository>()); In the past, we've always created a specific interface on each repository that inherited from the generic one, and used the default scanner to automatically wire all of those instances, but I'd like to be able to ask specifically for an IRepository<Account> without cluttering up the project with additional interfaces / configurations.

    Read the article

  • StrcutureMap Wiring - Sanity Check Please

    - by Steve Ward
    Hi - Im new to IOC and StructureMap and have an n-level application and am looking at how to setup the wirings (ForRequestedType ...) and just want to check with people with more experience that this is the best way of doing it! I dont want my UI application object to reference my persistence layer directly so am not able to wire everything up in this UI project. I now have it working by defining a Registry class in each project which wires up the types in the project as needed. The layer above registers its types and also calls the assembly below and looks for registries so that all types are registered throught the hierrachy. E.g. I have UI, Service, Domain, and Persistence libraries. In my service layer the registry looks like Scan(x => { x.Assembly("MyPersistenceProject"); x.LookForRegistries(); }); ForRequestedType<IService>().TheDefault.Is.OfConcreteType<MyService>(); Is this a recommended way of doing this in a setup such as this? Are there better ways and what are the advantages / disadvantages of these approaches in this case?

    Read the article

  • Autofac wiring question - beginner

    - by user645788
    Beginners question: Given two classes: Myclass5 and Myclass6 how can one wire up following factory method (returned as Func) such that myclass5 and myclass6 instances and IMyClass that they depend on are all retrieved via autofac (assuming that these three instances are registered). public static MyClass4 FactoryMethod(int nu) { if (nu == 1) return new MyClass5(....); if (nu == 4) return new MyClass6(....); throw new NotImplementedException(); } public abstract class MyClass4 { } public class MyClass5 : MyClass4 { public MyClass5(int nu, IMyClass a) { } } public class MyClass6 : MyClass4 { public MyClass6(int nu, IMyClass a) { } }

    Read the article

1 2 3 4 5 6 7 8  | Next Page >