Search Results

Search found 196 results on 8 pages for 'wiring'.

Page 2/8 | < Previous Page | 1 2 3 4 5 6 7 8  | Next Page >

  • Manually wiring up unobtrusive jquery validation client-side without Model/Data Annotations, MVC3

    - by cmorganmcp
    After searching and experimenting for 2 days I relent. What I'd like to do is manually wire up injected html with jquery validation. I'm getting a simple string array back from the server and creating a select with the strings as options. The static fields on the form are validating fine. I've been trying the following: var dates = $("<select id='ShiftDate' data-val='true' data-val-required='Please select a date'>"); dates.append("<option value=''>-Select a Date-</option>"); for (var i = 0; i < data.length; i++) { dates.append("<option value='" + data[i] + "'>" + data[i] + "</option>"); } $("fieldset", addShift).append($("<p>").append("<label for='ShiftDate'>Shift Date</label>\r").append(dates).append("<span class='field-validation-valid' data-valmsg-for='ShiftDate' data-valmsg-replace='true'></span>")); // I tried the code below as well instead of adding the data-val attributes and span manually with no luck dates.rules("add", { required: true, messages: { required: "Please select a date" } }); // Thought this would do it when I came across several posts but it didn't $.validator.unobtrusive.parse(dates.closest("form")); I know I could create a view model ,decorate it with a required attribute, create a SelectList server-side and send that, but it's more of a "how would I do this" situation now. Can anyone shed light on why the above code wouldn't work as I expect? -chad

    Read the article

  • GridBoundColumn OnTextChanged event wiring

    - by Kobojunkie
    I have a GridBoundColumn in my RadGrid that should accept Zip input and based on input auto populates the State and City fields on my form. I would like to wire this up in such a way as to call a webservice on the back end or maybe repost the form only when the GridBoundColumn is changed. How do I wire this up please? Thanks in Advance

    Read the article

  • castle windsor container not wiring properties correctly

    - by Damian
    I have a class that i want to instantiate thru castle in configuration. public class MyMappings : IMappings { Mapping FirstMapping { get; set; } Mapping SecondMapping { get; set; } OtherType ThirdMapping { get; set; } OtherType FourthMapping { get; set; } Mapping FifthMapping { get; set; } OtherType SixMapping { get; set; } } In my configuration i have the following: ${anothercomponentIDForCompomentOftypeMapping} The problem i am facing is that is assigning the same value to all properties of the same type, completly ignoring the name of the parameter. This properties are optional, i just want to initialize the value for one of them. Thanks,

    Read the article

  • Strategy for wiring up events?

    - by Jeffrey Cameron
    I'm using Ninject (1.5 ... soon to be 2) and I'm curious how other people use Ninject or other IoC containers to help wire up events to objects? It seems to me in my code that I'm doing it herky-jerky all over the place and would love some advice on how to clean it up a bit. What are people doing out there to manage this?

    Read the article

  • Struts1 and Spring wiring question

    - by Dev er dev
    Recently I had a pleasure of working again on Struts 1.1 application. It uses Spring 2.5, but not for actions. I would like to hook it up to use Spring as DI for Struts Actions also, as it would make my life a loot easier. I found out DelegatingRequestProcessor could be used for this purpose, at least according to documentation, but seems it has been deprecated as of Spring 3.0. Switching to the new version of Struts is not an option. Does anyone have better idea then starting to use deprecated stuff?

    Read the article

  • Network cabling with multiple patch panels?

    - by dannymcc
    I am in the very early stages of planning a network cabling upgrade in our office, mainly to upgrade the old cables from Cat5 to either 5e or 6. I am also planning on upgrading all of our 10/100 switches to 10/100/1000 switches. I would like to have three small wall mounted cabinets spread around the building, each with a patch panel and switch. These would all lead back to our server room. The question is; should I have two patch panels in each wall cabinet, one with 24 or 48 ports that are connected to a matching patch panel in the server room. The second patch panel would then link to each device in that cabinets area. Then I wouldn't put a switch in the small cabinets. All switching would be done in the server room. Or, should I have one main cable from the server room to each of the cabinets - plugged straight into the switch and the patch panel is for devices in the cabinets area? I hope that makes sense!

    Read the article

  • HP DX5150, MS-7050 v. 1.3 Motherboard front panel pin connectors

    - by Daniel
    I recently purchased and installed a MS-7050 v. 1.3 motherboard into a regular non-HP case and thus the front panel connectors are different than the original OEM connectors which are all bundled together. The HP support website does not have this information available and someone from HP indicated in response to a support forum question that this information is not available. What is the motherboard pin schematic for the front panel i/o connectors (power, reset, hdd led, and power led)?

    Read the article

  • In ear headphones with a long cable

    - by cust0s
    I'm looking for some in ear headphones with a long cable (no more than 3m). Is their such a product out there? I'm looking to spend no more than £30 ($50) If not could someone reccomend me some small headphones with a long cable?

    Read the article

  • kvm-over-ip, multiple machines per cable run

    - by Sirex
    I'm looking at getting a kvm-over-ip setup for a server room. Typically these devices have 16 or so cat5 leads that come out of them and then a convertor that converts each cat5 into a vga & ps2 pair. Can you run one cable from the unit into a switch, and then leads from the switch into each machine ? I have several machines on the other side of the server room that i'd like to have avaliable but i dont want to run 16 cables to them. I'm thinking this should be possible being IP layer and all, but as each device normally has its own cable out the back of the kvm unit i'm not certain. Perhaps the kvm's rear ports act essentially like a switch anyway in which case it should work, or perhaps if i run all 16 cables into a seperate switch right next to it and aggregate the ports together, run one cable to a switch on the other side of the room with similar number of ports agregated together, then use that switch to plug each macine into ? I'm fairly sure this is possible, but i just want to check before i shell out the cash as i've never tried it.

    Read the article

  • 3 wire computer fan won't run continuously

    - by Ben
    I had an old computer that didn't work anymore, so I took the CPU fan out to see what I could make with it. The fan is NMB model number BG0903-B044-VTL, like this. It has three wires coming off of it, red, black, and white. I know that the white wire is usually a speed sensor. Does this wire need to be connected to something in order for the fan to run continuously? Right now when I apply power to the red and black wires (from a 9-volt battery) the fan will spin very briefly, and then slow down until it stops. The fan's motor only spins in the instant that the power is turned on, but doesn't continue, even though the power is still applied. How can I get the fan to spin continuously?

    Read the article

  • Why is my Interface Builder wiring so bonkers and what can I do to straighten it out?

    - by editor
    I've been working on an iPhone application in XCode and Interface Builder of the Tab Bar project type. After getting a table view of topics (business sectors) working fine I realized that I would need to add a Navigation Control to allow the user to drill into a subtopics (subsectors) table. As a green Objective-C developer, that was confusing, but I managed to get it working by reading various documentation trying out a few different IB options. My current setup is a Tab Bar Controller with Tab 1 as a Navigation Controller and Tab 2 a plain view with a Table View placed into it. The wiring works: I can log when table rows are selected and I'm ready to push a new View Controller onto the stack so that I can display the subtopics Table View. My problem: For some reason the first tab's Table View is a delegate and dataSource of the second ta. It doesn't make sense to me and I can't figure out why that's the only setup that works. Here is the wiring: Navigation Controller (Sectors) is a delegate of Tab Bar Navigation Bar is a delegate of Navigation Controller (Sectors) View Contoller (Sectors) has a view of Table View Table View (in Navigation Controller (Sectors)) is a delegate of First View Controller (Companies) Table View (in Navigation Controller (Sectors)) is a dataSource outlet of First View Controller (Companies) First View Controller (Companies) First View Contoller (Sectors) has a view of Table View Table View (in First View Controller (Companies)) is not hooked up to a dataSource outlet and is not a delegate When I click the tab buttons and look at the Inspector I see that the first tab is correctly hooked up to my MainWindow.xib and the second tab has selected a nib called SecondView.xib. It's in the File's Owner of MainWindow.xib where I inherit UITableViewDataSource and UITableViewDelegate (and also UITabBarControllerDelegate) in the .h, and in the .m where I implement the delegate methods. Why does this setup only work when the Table View in my first tab (View Controller (Sectors)) is a delegate and dataSource of the second tab? I'm confused: why wouldn't it need to be hooked up to the Navigation Controller-enabled tab in which the Table View is seen (Navigation Controller (Sectors))? The Table View seen on the second tab has neither dataSource and is not a delegate. I'm having trouble getting a pushViewController to fire (self.navigationController is not nil but the new View Controller still doesn't load) and I suspect that I need to work out this IB wiring issue before I can troubleshoot why the Nav Controller won't push a new View Controller onto the stack. if(nil == self.navigationController) { NSLog(@"self.navigationController is nil."); } else { NSLog(@"self.navigationController is not nil."); SectorList *subsectorViewController = [[SectorList alloc] initWithNibName:@"SectorList" bundle:nil]; subsectorViewController.title = @"Subsectors"; [[self navigationController] pushViewController:subsectorViewController animated:YES]; [subsectorViewController release]; }

    Read the article

  • Have there been attempts to make object containers that search for valid programs by auto wiring compatible components?

    - by Aaron Anodide
    I hope this post isn't too "Fringe" - I'm sure someone will just kill it if it is :) Three things made me want to reach out about this now: Decoupling is so in the forefront of design. TDD inspires the idea that it doesn't matter how a program comes to exist as long as it works. Seeing how often the adapter pattern is applied to achieve (1). I'm almost sure this has been tried from a memory of reading about it around the year 2000 or so. If I had to guess, it was maybe about and earlier version of the Java Spring framework. At this time we were not so far from days when the belief was that computer programs could exhibit useful emergent behavior. I think the article said it didn't work, but it didn't say it was impossible. I wonder if since then it has been deemed impossible or simply an illusion due to a false assumption of similarity between a brain and a CPU. I know this illusion existed because I had an internship in 1996 where I programmed neural nets that were supposedly going to exhibit "brain damage". STILL, after all that, I'm sitting around this morning and not able to shake the idea that it should be possible to have a method of programming to allow autonomous components to find each other, attempt to collaborate and their outputs evaluated against a set desired results.

    Read the article

  • Tab Bar and Nav Controller: Where did I go wrong in my Interface Builder wiring?

    - by editor
    Even if you don't know how I've shot myself in the foot, a story which I've tried to lay out below, if you think I've done a good job showing the parameters of my problem I'd appreciate an upvote so that I might be able to grab some attention for my question. I've been working on an iPhone application in XCode and Interface Builder of the Tab Bar project type. After getting a table view of topics (business sectors) working fine I realized that I would need to add a Navigation Control to allow the user to drill into a subtopics (subsectors) table. As a green Objective-C developer, that was confusing, but I managed to get it working by reading various documentation trying out a few different IB options. My current setup is a Tab Bar Controller with Tab 1 as a Navigation Controller and Tab 2 a plain view with a Table View placed into it. The wiring works: I can log when table rows are selected and I'm ready to push a new View Controller onto the stack so that I can display the subtopics Table View. My problem: For some reason the first tab's Table View is a delegate and dataSource of the second ta. It doesn't make sense to me and I can't figure out why that's the only setup that works. Here is the wiring: Navigation Controller (Sectors) is a delegate of Tab Bar Navigation Bar is a delegate of Navigation Controller (Sectors) View Contoller (Sectors) has a view of Table View Table View (in Navigation Controller (Sectors)) is a delegate of First View Controller (Companies) Table View (in Navigation Controller (Sectors)) is a dataSource outlet of First View Controller (Companies) First View Controller (Companies) First View Contoller (Sectors) has a view of Table View Table View (in First View Controller (Companies)) is not hooked up to a dataSource outlet and is not a delegate When I click the tab buttons and look at the Inspector I see that the first tab is correctly hooked up to my MainWindow.xib and the second tab has selected a nib called SecondView.xib. It's in the File's Owner of MainWindow.xib where I inherit UITableViewDataSource and UITableViewDelegate (and also UITabBarControllerDelegate) in the .h, and in the .m where I implement the delegate methods. Why does this setup only work when the Table View in my first tab (View Controller (Sectors)) is a delegate and dataSource of the second tab? I'm confused: why wouldn't it need to be hooked up to the Navigation Controller-enabled tab in which the Table View is seen (Navigation Controller (Sectors))? The Table View seen on the second tab has neither dataSource and is not a delegate. I'm having trouble getting a pushViewController to fire (self.navigationController is not nil but the new View Controller still doesn't load) and I suspect that I need to work out this IB wiring issue before I can troubleshoot why the Nav Controller won't push a new View Controller onto the stack. if(nil == self.navigationController) { NSLog(@"self.navigationController is nil."); } else { NSLog(@"self.navigationController is not nil."); SectorList *subsectorViewController = [[SectorList alloc] initWithNibName:@"SectorList" bundle:nil]; subsectorViewController.title = @"Subsectors"; [[self navigationController] pushViewController:subsectorViewController animated:YES]; [subsectorViewController release]; }

    Read the article

  • Friday Fun: Christmas Tree Light Up

    - by Asian Angel
    Another week has thankfully passed by, so it is time to take a break and have some fun. This week’s game tests your ability to light up the whole Christmas tree…can you figure out the correct wiring configuration? Christmas Tree Light Up The object of the game is simple…light up all of the bulbs on the Christmas tree. While the game may look quick and easy at first you will need to do some thinking and experimenting to come up with the correct wiring configuration. The instructions are very simple…just click on any of the wiring sections or bulbs to rotate them. Keep in mind that you may have to click a few times to line the wiring sections or bulbs up as desired since the rotation is always clockwise. Note: You will need use all of the wiring sections available to completely light the tree up. Each time you will be presented with a different starting setup coming from your power source. Time to hook up the lights! Note: It is recommended that you disable the sound for the game since the “rotation” sounds can be slightly irritating. A nice start but there are still a lot of bulbs to light up. Getting closer… Almost there…only two more bulbs to light up. Success! Have fun playing! Play Christmas Tree Light Up Latest Features How-To Geek ETC The 50 Best Registry Hacks that Make Windows Better The How-To Geek Holiday Gift Guide (Geeky Stuff We Like) LCD? LED? Plasma? The How-To Geek Guide to HDTV Technology The How-To Geek Guide to Learning Photoshop, Part 8: Filters Improve Digital Photography by Calibrating Your Monitor Our Favorite Tech: What We’re Thankful For at How-To Geek Settle into Orbit with the Voyage Theme for Chrome and Iron Awesome Safari Compass Icons Set Escape from the Exploding Planet Wallpaper Move Your Tumblr Blog to WordPress Pytask is an Easy to Use To-Do List Manager for Your Ubuntu System Snowy Christmas House Personas Theme for Firefox

    Read the article

  • What's the VB.NET equivalent of this C# code for wiring up and declaring an event?

    - by Ben McCormack
    I'm working on a tutorial to build a media player in Silverlight and am trying to wire up an EventHandler to the timer.Tick event of a DispatchTimer object so that the time of the video is synced with a Slider object. The sample code is in C# and I can't for the life of me figure out the proper syntax in VB.NET with RaiseEvent and/or Handles to wire up the event. Below is the relevant C# code. I'll include comments on where I'm getting stuck. private DispatchTimer timer; public Page() { //... timer = new DispatchTimer(); timer.Interval = TimeSpan.FromMilliseconds(50); timer.Tick += new EventHandler(timer_Tick); // <== I get stuck here b/c // I can't do "timer.Tick += ..." in VB.NET } void timer_Tick(object sender, EventArgs e) { if (VideoElement.NaturalDuration.TimeSpan.TotalSeconds > 0) { sliderScrubber.Value = VideoElement.Position.TotalSeconds / VideoElement.NaturalDuration.TimeSpan.TotalSeconds; } }

    Read the article

  • DIY CFL-Based Photography Light Is Bright and Cheap

    - by Jason Fitzpatrick
    This DIY build combines a bunch of off-the-shelf hardware parts for a cheap–both to build and run–continuous lighting studio lamp. The build guide is heavy on details regarding the construction of the body but light on wiring details so you’ll definitely want to brush up on your basic socket wiring skills before tackling it. Otherwise, it’s a great guide to building an inexpensive continuous lighting setup. Build A CFL Based Continuous Light Source [DIY Photography] How To Be Your Own Personal Clone Army (With a Little Photoshop) How To Properly Scan a Photograph (And Get An Even Better Image) The HTG Guide to Hiding Your Data in a TrueCrypt Hidden Volume

    Read the article

  • DI/IoC in Java for a .NET'er used to Castle.Windsor

    - by Ciddan
    Is there a Java DI container that works in a similar way to the most excellent Castle.Windsor container on the .NET side? The Java containers I've had a look at all seem to rely on annotations (Guice) within my services, which I don't dig all that much - I'd like to go POJO all the way if possible. Spring on the other hand can do without the annotations, but it requires a lot of XML. XML configuration != maintainability. One of the really nice things about Castle.Windsor is the wiring you're able to set up in code with Installers, auto wiring based on naming conventions and whatnot. Ideally the container should also support lifecycle management and configuration; i.e. registering components as transient, singleton, pooled etc. Another bonus would be support for interceptors. Any tips would be greatly appreciated.

    Read the article

  • Retrofit Certification

    - by Bill Evjen
    Impact of Regulations on Cabin Systems Installation John Courtright, Structural Integrity Engineering There are “heightened” FAA attention to technical issues related to IFE and Wi-Fi Systems Installations The Aging Aircraft Safety Rule – EWIS & Damage Tolerance Analysis The Challenge: Maximize Flight Safety While Minimizing Costs Issue Papers & Testing, Testing, Testing The role of Airworthiness Directives (ADs) on the design of many IFE systems and all antenna systems. Goal is safety AND cost-effective maintenance intervals and inspection techniques The STC Process Briefly Stated Type Certifications (TC) Supplemental Type Certifications (STC) The STC Process Project Specific Certification Plan (PSCP) Managed by FAA Aircraft Certification Office (ACO) Type of Project (Electrical/Mechanical Systems or Structural) Specific Type of Aircraft Being Modified Schedule Design & Installation Location What does the STC Plan (PSCP) Cover? System Description – What does the system do? System qualification – Are the components qualified? Certification requirements – What FARs are applicable? Installation detail – what is being modified? Prototype installation – What is new? Functional hazard Assessment (FHA) – is it safe? EZAP-EWIS Requirements – Any aging aircraft issues? Certification Data – How is compliance achieved? Delegation and FAA involvement – Who is doing the work? Proposed certification schedule – When is the installation? Certification documentation – What the FAA Expects to see Cabin Systems Certification Concerns In addition to meeting the requirements for DO-160, Cabin System Certification needs to address issues related to: Power management: Generally, IFE and Wi-Fi Systems are classified as “Non-Essential Equipment” from a certification viewpoint. Connected to “non-essential” power buses Must be able to shed IFE & Wi-Fi Systems in a smoke/fire event or Other electrical emergency (FAA Policy 00-111-160) FAA is more relaxed with testing wi-fi. It used to be that you had to have 150 seats with laptops running wi-fi, but now it is down to around 50. Aging aircraft concerns – electrical and structural Issue papers addressing technical concerns involving: “Structural Certification Criteria for Large Antenna Installations” Antenna “Vibration/Buffeting Compliance Criteria” DO-160 : Environmental Test Procedures DO 160 – “Environmental Conditions and Test Procedures for Airborne Equipment”, Issued by RTCA Provides guidance to equipment manufacturers as to testing requirements Temperature: –40C to +55C Vibration and Shock Contaminant susceptibility – fluids and dust Electro-magnetic Interference Cabin systems are generally classified as “non-essential” Swissair 111 crashed (in part) due to non-standard wiring practices. EWIS Design Implications Installation design must take EWIS Requirements into account. This generally means: Aircraft surveys are needed to identify proper wire routing Ensure existing wiring diagrams are correct Identify primary/Secondary/Tertiary bus locations Verify proper separation of wire bundles exist Required separation from fuel quantity indicator system (FQIS) to prevent fuel tang ignition Enhanced Zonal Analysis Procedure (EZAP) Performed EZAP was developed by the Aging Transport Systems Rulemaking Advisory Committee (ATSRAC) EZAP is the method for analyzing airplane zones with an emphasis on evaluating wiring systems and the existence of combustibles  in the cabin. Certification Considerations for Wi-Fi Systems Electrical – All existing DO 160 testing required Issue papers required Onboard EMI testing – any interference with aircraft systems when multiple wi-fi users are logged on? Vibration/Buffeting compliance criteria – what is the effect of the antenna on aircraft flight characteristics? Structural certification criteria – what are the stress loads on the aircraft at the antenna location and what is the impact on maintenance inspection criteria for the airline? Damage tolerance analysis required Goal – minimize maintenance inspection intervals

    Read the article

  • How to diagram custom programming languages, non textual?

    - by Adam
    I've used and created domain-specific languages before, plenty of times (e.g. using yacc/lex). Normally we'd start with grammar written in BNF, and a bunch of keywords. This is easy to do, easy to share. Recently, I've started working with diagrammatic programming languages - closest parallel is circuit-diagrams in electronics, where it's very difficult to express ideas in text, but very easy to express them in wiring-diagrams. This is a new and novel problem for me: how to efficiently express these mini-languages, and share concepts in them with colleagues? (i.e. how to whiteboard-program within them. Actual programming is easy - you have physical components to hand) Are there tools for this? Or good/best practices (e.g. equivalent of "always use BNF as starting point for your new DSL, and use tools like yacc to generate the parser, compiler, etc"). My googlefu is proving weak - all I get is false positives for wiring diagrams, and UML editors (since these are custom languages, UML doesn't seem to help)

    Read the article

  • Stand-Up Desk 2012 Update

    - by BuckWoody
    One of the more popular topics here on my technical blog doesn't have to do with technology, per-se - it's about the choice I made to go to a stand-up desk work environment. If you're interested in the history of those, check here: Stand-Up Desk Part One Stand-Up Desk Part Two I have made some changes and I was asked to post those here.Yes, I'm still standing - I think the experiment has worked well, so I'm continuing to work this way. I've become so used to it that I notice when I sit for a long time. If I'm flying, or driving a long way, or have long meetings, I take breaks to stand up and move around. That being said, I don't stand as much as I did. I started out by standing the entire day - which did not end well. As you can read in my second post, I found that sitting down for a few minutes each hour worked out much better. And over time I would say that I now stand about 70-80% of the day, depending on the day. Some days I don't even notice I'm standing, so I don't sit as often. Other days I find that I really tire quickly - so I sit more often. But in both cases, I stand more than I sit. In the first post you can read about how I used a simple coffee-table from Ikea to elevate my desktop to the right height. I then adjusted the height where I stand by using a small plastic square and some carpet. Over time I found this did not work as well as I'd like. The primary reason is that the front of these are at the same depth - so my knees would hit the desk or table when I sat down. Also, the desk was at a certain height, and I had to adjust, rather than the other way around.  Also, I like a lot of surface area on top of a desk - almost more of a table. Routing cables and wiring was a pain, and of course moving it was out of the question.   So I've changed what I use. I found a perfect solution for what I was looking for - industrial wire shelving: I bought one, built only half of it (for the right height I wanted) and arranged the shelves the way I wanted. I then got a 5'x4' piece of wood from Lowes, and mounted it to where the top was balanced, but had an over-hang  I could get my knees under easily.My wife sewed a piece of fake-leather for the top. This arrangement provides the following benefits: Very strong Rolls easily, wheels can lock to prevent rolling Long, wide shelves Wire-frame allows me to route any kind of wiring and other things all over the desk I plugged in my UPS and ran it's longer power-cable to the wall outlet. I then ran the router's LAN connection along that wire, and covered both with a large insulation sleeve. I then plugged in everything to the UPS, and routed all the wiring. I can now roll the desk almost anywhere in the room so that I can record, look out the window, get closer to or farther away from the door and more. I put a few boxes on the shelves as "drawers" and tidied that part up. Even my printer fits on a shelf. Laser-dog not included - some assembly required In the second post you can read about the bar-stool I purchased from Target for the desk. I cheaped-out on this one, and it proved to be a bad choice. Because I had to raise it so high, and was constantly sitting on it and then standing up, the gas-cylinder in it just gave out. So it became a very short stool that I ended up getting rid of. In the end, this one from Ikea proved to be a better choice: And so this arrangement is working out perfectly. I'm finding myself VERY productive this way. I hope these posts help you if you decide to try working at a stand-up desk. Although I was skeptical at first, I've found it to be a very healthy, easy way to code, design and especially present over a web-cam. It's natural to stand to speak when you're presenting, and it feels more energetic than sitting down to talk to others.

    Read the article

  • Dynamically creating GWT screens using Metadata?

    - by Francis Shanahan
    I have an AWT applet application that needs to be ported over to GWT. The applet screens are described in meta data and the applet renders each screen dynamically using reflection. We'd like the same thing in GWT/ExtGWT. I've built a working version of this ExtJS whereby the metadata is turned into ExtJS Screen configs in the form of JSON. The drawback with this approach is the "wiring" of controls to data needs to be written in Javascript. GWT is preferred since it'd be all Java code, no JS. Upon digging in it's possible to render the screens using GWT off the metadata using GWT.create(). The problem I'm having is the wiring to hook a dynamically created button for example to an event handler requires reflection which is not supported in GWT. Is this conclusion correct? and if so, are there any other ways to achieve this type of dynamic UI using ExtGWT?

    Read the article

  • How do I set up MVP for a Winforms solution?

    - by JonWillis
    Question moved from Stackoverflow - http://stackoverflow.com/questions/4971048/how-do-i-set-up-mvp-for-a-winforms-solution I have used MVP and MVC in the past, and I prefer MVP as it controls the flow of execution so much better in my opinion. I have created my infrastructure (datastore/repository classes) and use them without issue when hard coding sample data, so now I am moving onto the GUI and preparing my MVP. Section A I have seen MVP using the view as the entry point, that is in the views constructor method it creates the presenter, which in turn creates the model, wiring up events as needed. I have also seen the presenter as the entry point, where a view, model and presenter are created, this presenter is then given a view and model object in its constructor to wire up the events. As in 2, but the model is not passed to the presenter. Instead the model is a static class where methods are called and responses returned directly. Section B In terms of keeping the view and model in sync I have seen. Whenever a value in the view in changed, i.e. TextChanged event in .Net/C#. This fires a DataChangedEvent which is passed through into the model, to keep it in sync at all times. And where the model changes, i.e. a background event it listens to, then the view is updated via the same idea of raising a DataChangedEvent. When a user wants to commit changes a SaveEvent it fires, passing through into the model to make the save. In this case the model mimics the view's data and processes actions. Similar to #b1, however the view does not sync with the model all the time. Instead when the user wants to commit changes, SaveEvent is fired and the presenter grabs the latest details and passes them into the model. in this case the model does not know about the views data until it is required to act upon it, in which case it is passed all the needed details. Section C Displaying of business objects in the view, i.e. a object (MyClass) not primitive data (int, double) The view has property fields for all its data that it will display as domain/business objects. Such as view.Animals exposes a IEnumerable<IAnimal> property, even though the view processes these into Nodes in a TreeView. Then for the selected animal it would expose SelectedAnimal as IAnimal property. The view has no knowledge of domain objects, it exposes property for primitive/framework (.Net/Java) included objects types only. In this instance the presenter will pass an adapter object the domain object, the adapter will then translate a given business object into the controls visible on the view. In this instance the adapter must have access to the actual controls on the view, not just any view so becomes more tightly coupled. Section D Multiple views used to create a single control. i.e. You have a complex view with a simple model like saving objects of different types. You could have a menu system at the side with each click on an item the appropriate controls are shown. You create one huge view, that contains all of the individual controls which are exposed via the views interface. You have several views. You have one view for the menu and a blank panel. This view creates the other views required but does not display them (visible = false), this view also implements the interface for each view it contains (i.e. child views) so it can expose to one presenter. The blank panel is filled with other views (Controls.Add(myview)) and ((myview.visible = true). The events raised in these "child"-views are handled by the parent view which in turn pass the event to the presenter, and visa versa for supplying events back down to child elements. Each view, be it the main parent or smaller child views are each wired into there own presenter and model. You can literately just drop a view control into an existing form and it will have the functionality ready, just needs wiring into a presenter behind the scenes. Section E Should everything have an interface, now based on how the MVP is done in the above examples will affect this answer as they might not be cross-compatible. Everything has an interface, the View, Presenter and Model. Each of these then obviously has a concrete implementation. Even if you only have one concrete view, model and presenter. The View and Model have an interface. This allows the views and models to differ. The presenter creates/is given view and model objects and it just serves to pass messages between them. Only the View has an interface. The Model has static methods and is not created, thus no need for an interface. If you want a different model, the presenter calls a different set of static class methods. Being static the Model has no link to the presenter. Personal thoughts From all the different variations I have presented (most I have probably used in some form) of which I am sure there are more. I prefer A3 as keeping business logic reusable outside just MVP, B2 for less data duplication and less events being fired. C1 for not adding in another class, sure it puts a small amount of non unit testable logic into a view (how a domain object is visualised) but this could be code reviewed, or simply viewed in the application. If the logic was complex I would agree to an adapter class but not in all cases. For section D, i feel D1 creates a view that is too big atleast for a menu example. I have used D2 and D3 before. Problem with D2 is you end up having to write lots of code to route events to and from the presenter to the correct child view, and its not drag/drop compatible, each new control needs more wiring in to support the single presenter. D3 is my prefered choice but adds in yet more classes as presenters and models to deal with the view, even if the view happens to be very simple or has no need to be reused. i think a mixture of D2 and D3 is best based on circumstances. As to section E, I think everything having an interface could be overkill I already do it for domain/business objects and often see no advantage in the "design" by doing so, but it does help in mocking objects in tests. Personally I would see E2 as a classic solution, although have seen E3 used in 2 projects I have worked on previously. Question Am I implementing MVP correctly? Is there a right way of going about it? I've read Martin Fowler's work that has variations, and I remember when I first started doing MVC, I understood the concept, but could not originally work out where is the entry point, everything has its own function but what controls and creates the original set of MVC objects.

    Read the article

  • T-SQL Tuesday #13: Clarifying Requirements

    - by Alexander Kuznetsov
    When we transform initial ideas into clear requirements for databases, we typically have to make the following choices: Frequent maintenance vs doing it once. As we are clarifying the requirements, we need to determine whether we want to concinue spending considerable time maintaining the system, or if we want to finish it up and move on to other tasks. Race car maintenance vs installing electric wiring is my favorite analogy for this kind of choice. In some cases we need to sqeeze every last bit...(read more)

    Read the article

< Previous Page | 1 2 3 4 5 6 7 8  | Next Page >