Search Results

Search found 49 results on 2 pages for 'adaptec'.

Page 1/2 | 1 2  | Next Page >

  • Gigabyte Motherboard + Adaptec RAID = No Booting from any drives

    - by Farseeker
    I have a brand new PC, just out of the box. It has a Gigabyte GA-P55-USB3 motherboard. I also have an Adaptec ASR-2504 SAS RAID card with 2x 15k Seagate Barracuda SAS drives attached. After the motherboard init's its on-board RAID it then init's the Adaptec RAID. It detects all the RAID devices OK, but when it gets to Loading Operating System... (i.e. right before it should load the OS) it just sits there forever, doing nothing: If I force it to boot from the optical drive, you see it spin up for a few seconds then die down again. If I remove the Adaptec RAID card, everything works perfectly. As soon as it's plugged back in, it never gets past that stage. The RAID card should be perfectly fine (it was before), but I have raised a case with Adaptec anyway. Any suggestions on what I can try to get these two to play nicely together?

    Read the article

  • Adaptec 5805 after reboot don't starting

    - by Rakedko ShotGuns
    After rebooting the system, the controller is not included. It only works if the computer is shut down and turn off. Late i update firmware "Adaptec RAID 5805 Firmware Build 18948" How to fix the problem? add Log Configuration summary Server name.....................raid_test Adaptec Storage Manager agent...7.31.00 (18856) Adaptec Storage Manager console.7.31.00 (18856) Number of controllers...........1 Operating system................Windows Configuration information for controller 1 ------------------------------------------------------- Type............................Controller Model...........................Adaptec 5805 Controller number...............1 Physical slot...................2 Installed memory size...........512 MB Serial number...................8C4510C6C9E Boot ROM........................5.2-0 (18948) Firmware........................5.2-0 (18948) Device driver...................5.2-0 (16119) Controller status...............Optimal Battery status..................Charging Battery temperature.............Normal Battery charge amount (%).......37 Estimated charge remaining......0 days, 16 hours, 12 minutes Background consistency check....Disabled Copy back.......................Disabled Controller temperature..........Normal (40C / 104F) Default logical drive task priorityHigh Performance mode................Dynamic Number of logical devices.......1 Number of hot-spare drives......0 Number of ready drives..........0 Number of drive(s) assigned to MaxCache cache0 Maximum drives allowed for MaxCache cache8 MaxCache Read Cache Pool Size...0 GB NCQ status......................Enabled Stay awake status...............Disabled Internal drive spinup limit.....0 External drive spinup limit.....0 Phy 0...........................No device attached Phy 1...........................No device attached Phy 2...........................No device attached Phy 3...........................1.50 Gb/s Phy 4...........................No device attached Phy 5...........................No device attached Phy 6...........................No device attached Phy 7...........................No device attached Statistics version..............2.0 SSD Cache size..................0 Pages on fetch list.............0 Fetch list candidates...........0 Candidate replacements..........0 69319...........................31293 Logical device..................0 Logical device name............. RAID level......................Simple volume Data space......................148,916 GB Date created....................09/19/2012 Interface type..................Serial ATA State...........................Optimal Read-cache mode.................Enabled Preferred MaxCache read cache settingEnabled Actual MaxCache read cache setting Disabled Write-cache mode................Enabled (write-back) Write-cache setting.............Enabled (write-back) Partitioned.....................Yes Protected by hot spare..........No Bootable........................Yes Bad stripes.....................No Power Status....................Disabled Power State.....................Active Reduce RPM timer................Never Power off timer.................Never Verify timer....................Never Segment 0.......................Present: controller 1, connector 0, device 0, S/N 9RX3KZMT Overall host IOs................99075 Overall MB......................4411203 DRAM cache hits.................71929 SSD cache hits..................0 Uncached IOs....................29239 Overall disk failures...........0 DRAM cache full hits............71929 DRAM cache fetch / flush wait...0 DRAM cache hybrid reads.........3476 DRAM cache flushes..............-- Read hits.......................0 Write hits......................0 Valid Pages.....................0 Updates on writes...............0 Invalidations by large writes...0 Invalidations by R/W balance....0 Invalidations by replacement....0 Invalidations by other..........0 Page Fetches....................0 0...............................0 73..............................10822 8...............................3 46138...........................4916 27184...........................15226 20875...........................323 16982...........................1771 1563............................5317 1948............................2969 Serial attached SCSI ----------------------- Type............................Disk drive Vendor..........................Unknown Model...........................ST3160815AS Serial Number...................9RX3KZMT Firmware level..................3.AAD Reported channel................0 Reported SCSI device ID.........0 Interface type..................Serial ATA Size............................149,05 GB Negotiated transfer speed.......1.50 Gb/s State...........................Optimal S.M.A.R.T. error................No Write-cache mode................Write back Hardware errors.................0 Medium errors...................0 Parity errors...................0 Link failures...................0 Aborted commands................0 S.M.A.R.T. warnings.............0 Solid-state disk (non-spinning).false MaxCache cache capable..........false MaxCache cache assigned.........false NCQ status......................Enabled Phy 0...........................1.50 Gb/s Power State.....................Full rpm Supported power states..........Full rpm, Powered off 0x01............................113 0x03............................98 0x04............................99 0x05............................100 0x07............................83 0x09............................75 0x0A............................100 0x0C............................99 0xBB............................100 0xBD............................100 0xBE............................61 0xC2............................39 0xC3............................69 0xC5............................100 0xC6............................100 0xC7............................200 0xC8............................100 0xCA............................100 Aborted commands................0 Link failures...................0 Medium errors...................0 Parity errors...................0 Hardware errors.................0 SMART errors....................0 End of the configuration information for controller 1 List item

    Read the article

  • Adaptec 5805 not recognized after reboot

    - by Rakedko ShotGuns
    After rebooting the system, the controller is not recognized. It only works if the computer is shut down and turned off. I have recently updated the firmware to "Adaptec RAID 5805 Firmware Build 18948". How do I fix the problem? Configuration summary --------------------------- 1. Server name.....................raid_test Adaptec Storage Manager agent...7.31.00 (18856) Adaptec Storage Manager console.7.31.00 (18856) Number of controllers...........1 Operating system................Windows Configuration information for controller 1 ------------------------------------------------------- Type............................Controller Model...........................Adaptec 5805 Controller number...............1 Physical slot...................2 Installed memory size...........512 MB Serial number...................8C4510C6C9E Boot ROM........................5.2-0 (18948) Firmware........................5.2-0 (18948) Device driver...................5.2-0 (16119) Controller status...............Optimal Battery status..................Charging Battery temperature.............Normal Battery charge amount (%).......37 Estimated charge remaining......0 days, 16 hours, 12 minutes Background consistency check....Disabled Copy back.......................Disabled Controller temperature..........Normal (40C / 104F) Default logical drive task priority High Performance mode................Dynamic Number of logical devices.......1 Number of hot-spare drives......0 Number of ready drives..........0 Number of drive(s) assigned to MaxCache cache0 Maximum drives allowed for MaxCache cache8 MaxCache Read Cache Pool Size...0 GB NCQ status......................Enabled Stay awake status...............Disabled Internal drive spinup limit.....0 External drive spinup limit.....0 Phy 0...........................No device attached Phy 1...........................No device attached Phy 2...........................No device attached Phy 3...........................1.50 Gb/s Phy 4...........................No device attached Phy 5...........................No device attached Phy 6...........................No device attached Phy 7...........................No device attached Statistics version..............2.0 SSD Cache size..................0 Pages on fetch list.............0 Fetch list candidates...........0 Candidate replacements..........0 69319...........................31293 Logical device..................0 Logical device name............. RAID level......................Simple volume Data space......................148,916 GB Date created....................09/19/2012 Interface type..................Serial ATA State...........................Optimal Read-cache mode.................Enabled Preferred MaxCache read cache settingEnabled Actual MaxCache read cache setting Disabled Write-cache mode................Enabled (write-back) Write-cache setting.............Enabled (write-back) Partitioned.....................Yes Protected by hot spare..........No Bootable........................Yes Bad stripes.....................No Power Status....................Disabled Power State.....................Active Reduce RPM timer................Never Power off timer.................Never Verify timer....................Never Segment 0.......................Present: controller 1, connector 0, device 0, S/N 9RX3KZMT Overall host IOs................99075 Overall MB......................4411203 DRAM cache hits.................71929 SSD cache hits..................0 Uncached IOs....................29239 Overall disk failures...........0 DRAM cache full hits............71929 DRAM cache fetch / flush wait...0 DRAM cache hybrid reads.........3476 DRAM cache flushes..............-- Read hits.......................0 Write hits......................0 Valid Pages.....................0 Updates on writes...............0 Invalidations by large writes...0 Invalidations by R/W balance....0 Invalidations by replacement....0 Invalidations by other..........0 Page Fetches....................0 0...............................0 73..............................10822 8...............................3 46138...........................4916 27184...........................15226 20875...........................323 16982...........................1771 1563............................5317 1948............................2969 Serial attached SCSI ----------------------- Type............................Disk drive Vendor..........................Unknown Model...........................ST3160815AS Serial Number...................9RX3KZMT Firmware level..................3.AAD Reported channel................0 Reported SCSI device ID.........0 Interface type..................Serial ATA Size............................149,05 GB Negotiated transfer speed.......1.50 Gb/s State...........................Optimal S.M.A.R.T. error................No Write-cache mode................Write back Hardware errors.................0 Medium errors...................0 Parity errors...................0 Link failures...................0 Aborted commands................0 S.M.A.R.T. warnings.............0 Solid-state disk (non-spinning).false MaxCache cache capable..........false MaxCache cache assigned.........false NCQ status......................Enabled Phy 0...........................1.50 Gb/s Power State.....................Full rpm Supported power states..........Full rpm, Powered off 0x01............................113 0x03............................98 0x04............................99 0x05............................100 0x07............................83 0x09............................75 0x0A............................100 0x0C............................99 0xBB............................100 0xBD............................100 0xBE............................61 0xC2............................39 0xC3............................69 0xC5............................100 0xC6............................100 0xC7............................200 0xC8............................100 0xCA............................100 Aborted commands................0 Link failures...................0 Medium errors...................0 Parity errors...................0 Hardware errors.................0 SMART errors....................0 End of the configuration information for controller 1

    Read the article

  • Expanding RAID 1 array size (Adaptec 1420SA controller)

    - by cincura.net
    I have an Adaptec 1420SA controller in server and RAID 1 array created. The old disks slowly started to report S.M.A.R.T errors so I replaced first one, rebuild array and then other one and rebuild the array again. But the new drives are bigger, so I'd like to expand the array to use full disk capacity. Is it somehow possible? In the Adaptec configuration utility, after POST, I didn't found anything that could do it. I still have the old drives, if it helps. The array is used for system (Windows 2008 R2 SP1) booting. Thanks.

    Read the article

  • Adaptec 2420SA RAID 1 rebuild 66% after 1 week

    - by moss
    We're running a 500GB RAID 1 on an Adaptec 2420SA - 2x500GB Hitachi Drives. It suddenly crashed and required a rebuild -- was not even booting. It's only at 66% after about a week. Very frustrated. This is the second box with the same card and drives that has had issues with the RAID/drives. Another box had this happen twice. Both machines are Linux boxes. CentOS and Fedora. I dunno if it's the firmware -- which currently needs an update (any help doing this over PXE would be great- I have used UDA to do PXE boots in the past). Anyway, would love to hear about experiences with this card and firmware. I thinking of going google and just using cheap boxes no raid and have server redundancy instead.

    Read the article

  • Adaptec 6405 RAID controller turned on red LED

    - by nn4l
    I have a server with an Adaptec 6405 RAID controller and 4 disks in a RAID 5 configuration. Staff in the data center called me because they noticed a red LED was turned on in one of the drive bays. I have then checked the status using 'arcconf getconfig 1' and I got the status message 'Logical devices/Failed/Degraded: 2/0/1'. The status of the logical devices was listed as 'Rebuilding'. However, I did not get any suspicious status of the affected physical device, the S.M.A.R.T. setting was 'no', the S.M.A.R.T. warnings were '0' and also 'arcconf getsmartstatus 1' returned no problems with any of the disk drives. The 'arcconf getlogs 1 events tabular' command gives lots of output (sorry, can't paste the log file here as I only have remote console access, I could post a screenshot though). Here are some sample entries: eventtype FSA_EM_EXPANDED_EVENT grouptype FSA_EXE_SCSI_GROUP subtype FSA_EXE_SCSI_SENSE_DATA subtypecode 12 cdb 28 00 17 c4 74 00 00 02 00 00 00 00 data 70 00 06 00 00 00 00 00 00 00 00 00 02 00 00 00 00 00 00 00 00 00 00 00 00 0 The 'arcconf getlogs 1 device tabular' command reports mediumErrors 1 for two of the disks. Today, I have checked the status of the controller again. Everything is back to normal, the controller status is now 'Logical devices/Failed/Degraded: 2/0/0', the logical devices are also all back to 'Optimal'. I was not able to check the LED status, my guess is that the red LED is off again. Now I have a lot of questions: what is a possible cause for the medium error, why it is not reported by the SMART log too? Should I replace the disk drives? They were purchased just a month ago. The rebuilding process took one or two days, is that normal? The disks are 2 TByte each and the storage system is mostly idling. the timestamp of the logs seem to show the moment of the log retrieval, not the moment of the incident. Please advise, all help is very appreciated.

    Read the article

  • Will this RAID5 setup work (3TB Seagate Barracudas + Adaptec RAID 6405)?

    - by Slayer537
    As the title states, will this RAID combo work, and if not what needs to be changed? Overall opinions would be most helpful. I currently run a small file server of about 5TB or so. I keep outgrowing my needs and need to build a RAID setup that will allow me to expand as needed. I am new to RAID setups, especially one of the scale I have currently planned out, but I have being doing some research for the past couple of weeks and have come up with a build. Ideally, I'd have the setup completely built, but I'd like to keep the total cost around $1k and can't afford to go above $1.5k, so unfortunately that's not an option. 2 of my current drives are WD Caviar Blacks 2TB; however, I have recently learned that due to the lack of TLER those drives are awful for any RAID setup other than 0 or 1. That being said, my third drive is a Seagate Barracuda 3TB (ST300DM001) and I have found a RAID controller that states it supports it, so I'd like to use this same type of drive, if possible. Have any of you had any experience using this drive or a similar one in a RAID5 configuration? The manufacturer states that it supports it, but knowing that it is not an enterprise drive, I am slightly concerned that it could drop out of the array. I would just go with enterprise drives, but those are about double in cost... Parts list: Storage rack: http://www.ebay.com/itm/SGI-3U-Media-Storage-Server-16-Hard-Drive-Bay-SATA-SAS-Expander-Omnistor-SE3016-/140735776937?pt=LH_DefaultDomain_0&hash=item20c48188a9 3 more HDs (for now..): http://www.amazon.com/Seagate-Barracuda-3-5-Inch-Internal-ST3000DM001/dp/B005T3GRLY/ref=dp_return_2?ie=UTF8&n=172282&s=electronics Adaptec RAID 6405: http://www.newegg.com/Product/Product.aspx?Item=N82E16816103224 here's a link to the compatibility sheet if that helps: http://download.adaptec.com/pdfs/compatibility_report/arc-sas_cr_03-27-12_series6.pdf SAS expander cable: http://www.pc-pitstop.com/sas_cables_adapters/8887-2M.asp My plan is to install the RAID card in my computer and then route the SAS cable to the rack. Setup a RAID5 on 3 drives, transfer my data over from my other drive, and then add that drive to the array. Eventually, I'd like to get a 2U unit and run the file server on that and move the RAID card over to there, but that will have to happen later on. Side note: The computer the card would be going into will be running Windows 7 Pro with 24GB of DDR3-1600 and an i7-930.

    Read the article

  • new hard drive on Dell Adaptec 2610SA 6 port SATA RAID PCI card

    - by Ragnarok85
    I have a Dell Adaptec 2610SA 6 port SATA RAID PCI card with 3 hard drives on it and everything works fine. I plugged another hard drive to it and the system (Ubuntu 12.04, 64 bit) seems not to recognize it. Strange thing is that, as happened in the past, if I re-install the system, it recognizes the new hardware plugged to RAID card. Of course I don't want to re-install ubuntu each time I plug a new hard drive on my RAID card. Any idea? Thank you in advance

    Read the article

  • Adaptec 2020SA RAID controller Set up in RAID5, one drive went down, can I still get data?

    - by SJaguar13
    I have 6 1tb drives in a RAID5. 1 drive went down. On the RAID was 2 virtual machines that I really need back up and running. The spare drive I have to put in the server is a 1.5tb drive, which exceeds the physical per drive limit of the 2020SA. The drive is found in the disk utility, but it is not found in the array management section. I cannot add the drive to the array to have it rebuild. I have a replacement drive along with some spares on their way from Newegg, but I am still looking at a few days of downtime. Is it possible to use the 5 working drives to get the VMs copied off and on to another server or do I just have to wait for the drives to get here?

    Read the article

  • Use a RAID Controller without drivers?

    - by cian1500ww
    Ordered an Adaptec 1420SA RAID card for my Debian Squeeze media server but didn't check to see if it was compatible, turns out it's not because it uses something called hostRAID which requires special drivers that aren't available for Debian. Could I still use the card as an ordinary controller and just use OS software RAID?? I'm not looking for speed, just need to mirror some drives that will be used for storage, the OS will reside on a disk connected to the server's onboard controller so the system won't be booting from any drives on the Adaptec controller.

    Read the article

  • Computer hangs at boot screen with new RAID card

    - by shanethehat
    I am trying to build a new server around a Biostar TH61 motherboard and an Adaptec 6405E RAID controller card. The machine booted fine from USB before the RAID card and drives were installed. After installing, on the first boot the card was detected, but then started to spit out the following message every 10 seconds: Error: Controller Kernel Stopped Running << Press any key to continue ... Following the troubleshooting guide I unplugged everything, reseated the card, and reattached all the drives. This time the machine is sitting on the boot screen without any error messages and flashing a cursor, but after 15 minutes of this, nothing seems to be happening. Given that there are no error messages I'm hesitant to reboot again. Is it normal for a RAID card to sit without a status message when it firsts boots, maybe to initialise the drives or something? The current screen output looks a bit like this: Controller #00 found at PCI Slot:01, Bus:01, Dev:00, Func:00 Controller Model: Adaptec 6405E Firmware Version: 5.2-0[18512] Memory Size: 128MB Serial number: 111111111111111 SAS WWN: 50000D1104AE9180 _ Update: So after waiting 30 minutes I've rebooted back to the Kernal Stopped Running error. Maybe time to update the RAID BIOS.

    Read the article

  • How to set up raid monitoring on a Adaptec AAC-RAID on a Dell?

    - by pjz
    I've got Debian on a Dell with an Adaptec RAID: AAC0: kernel 4.1-0[7417] AAC0: monitor 4.1-0[7417] AAC0: bios 4.1-0[7417] AAC0: serial 4edf09 scsi2 : aacraid Vendor: CERC Model: DATA 1 Rev: V1.0 Type: Direct-Access ANSI SCSI revision: 02 Vendor: CERC Model: Data 2 Rev: V1.0 Type: Direct-Access ANSI SCSI revision: 02 I've got it set up using the fine afacli tool (ick). Is there a way to get it to email me when there's an error? Do I need to hand-roll a script for this? what's the right version of the afacli tool to use? v4.1 gets SIGABRT and exits after I ask it to 'container list' or 'enclosure list' v2.8's enclosure commands don't work either Do I need to upgrade firmware? to what? from where? how?

    Read the article

  • Same SCSI drive appears multiple times on the controller list

    - by ohad
    Hi, I have an Adaptec AHA-2940UW SCSI adapter, to which I connected a single Atlas 10K III drive (and nothing more). When my computer loads up, the pre-OS Adaptec screen shows (I believe this is called the POST screen), where I can see the Atlas drive listed many times (i.e. with ID0, ID1, ... ID5, ID7, ID8,...,ID15 [ID6 is the adapter itself]) Using the same HD on an Adaptec AHA-2940UB the disk only shows once Since my OS hasn't been installed yet, I'm not sure if this is a problem (I would guess it is), and if so - how to solve it. Termination and multiple LUNs come mind, but the cable provides termination and I don't see why a hard drive would request multiple LUNs, especially considering it is not jumpered at all, and multuple LUN support is disabled in the Adaptec controller BIOS (via the SCSISelect utility) Thank you

    Read the article

  • Is it normal for a SAS drive to have a few bad blocks, or should I replace my drive ASAP?

    - by Nate
    I have a drive—part of a RAID 1 mirror—that has two bad blocks. Adaptec Storage Manger e-mailed me when it detected the blocks. It shows 4 medium errors for that drive, but state is still “optimal”. This is my first time using Adaptec RAID controllers. I don’t know if an occasional bad block is normal, or if I should immediately replace that drive. Update: The drive failed later the same day! The disk subsystem is: Adaptec 6405 with ZMM (2) Seagate near-line SAS drives (ST31000424SS) The other drive hasn’t reported any bad blocks yet. I am running a consistency check.

    Read the article

  • migrating storage to a different controller

    - by bellocarico
    Hello, I've just purcheased a couple of adaptec controller (2405/5405) for my ESXi 4.0 U1 servers. Currently ESXi and a couple of VMs are hosted on single sata boot disk connected to a nvidia on board non-RAID controller. I know that it's possible to migrate from single disk to RAID 1 with adaptec and I'm pleased with that, but I'm not sure if ESXi has already the right drivers installed/loaded for this controller. Is there any way I can check this? Is ESXi clever enough to recognize the new hardware and load the right module? Thanks

    Read the article

  • How to identify RAID (5 or 6) controllers that allow dynamic resize of the array

    - by David Pfeffer
    I'm building a server with a RAID5 array, based on a hardware controller. I want to be able to later add additional disks and have the array rebalance across all of the disks, enlarging the usable size. I also want to be able to later upgrade to bigger disks (one at a time, of course) and then expand the array to fill the entire drive. These features are available in Linux software raid (md). I've also heard they're available in some hardware controllers. Currently, I own the Adaptec RAID 3805 card and the 3ware 9650se card. I'd prefer to use the Adaptec if possible, but I can't find if either of these cards offer this feature. If they don't, are there other affordable (read as: sub-$600) RAID cards available that can accomplish this?

    Read the article

  • Which SATA controller is better to use with Windows Server 2008 R2 64 bit?

    - by at8eqeq3
    We're preforming some hardware upgrade on our server machines. As a part of this process, we have to install some additional disk drives. Unfortunately, total number of drives will become 7 or 8, while all of our motherboards have only 6 SATA ports. Obviously, we need additional disk controllers. For now, we've tested Silicon Image (actually, no-name) and Adaptec controllers, both on SiI3132 chip, and got some problems with drivers for them: Silicon Image drivers are not installing at all, and Adaptec ones are installing, but the system says they're not signed and becomes unbootable. We're tryed both drivers from controllers' CD's and latest versions from manufacturers' websites, and no luck. So, can you recommend some SATA controllers that will really work without tambourine dances on mentioned OS (we need just 2 SATA ports and PCI-E, while RAID and any other features are no-matter)? Thanks for any help.

    Read the article

  • Data Store/Volume disconnecting. How to resume copy of VMDK?

    - by Serge
    I'm having an issue with my ESXi 4.1 hosts losing the datastore with FC SAN after a power outage. All 3 hosts disconnect so it's definitely a SAN issue. I've tried to resolve the issue on the SAN side with the SAN software support and Adaptec hardware support. No luck there. So I'm stuck with a SAN that will randomly disconnect the volume. I need to get the virtual machines (VMDK files) from the datastore. The problem is I can only get 5-20% before the data store disconnects. I have backups that are slightly older that I can use to replicate the VMDK differences to. What has not worked so far: Powering up the VMs, will boot up for 5-15 minutes then freeze vCenter migrate or clone of VM, will fail after similar period of time vCenter copy/paste of VMDK. Was able to get one 30GB VMDK and no luck after that. vMware Data Recovery. Fails at low %, can't resume, so next backup starts from begining. Veeam Backup & Recovery. Same as above, no resume function. If I can just find a backup solution that will resume from the failed spot that would solve my issue. Anyone have any ideas that I could try? EDIT 1 The SAN is Open-E DSS 6 running on a Supermicro 24 drive enclosure with 4 port Qlogic FC. Adaptec 52445 RAID card.

    Read the article

  • Storage device not found on ESX4 with AIC-9410

    - by Mads
    I am trying to install ESX 4.0 update 1 on a Supermicro X7DBR-3 system with an embedded AIC-9410 HBA (this HBA is listed on the HCG with Vendor ID 9005 and Device ID 041f) . All SATA controllers are disabled in the BIOS and the logical drive shows up in the Adaptec device summary during POST, however there is nothing listed on the Storage Device screen. The HBA itself is listed if I run esxcfg-info but not if I run esxcfg-scsidevs -a (under ESXi for that last command) Any ideas where I can look next or what might be wrong?

    Read the article

  • Mac Pro Boot Camp w/ RAID card

    - by churnd
    If I configure a Mac Pro with a RAID card and two 15k RPM drives, and leave the drives JBOD (no RAID configured), can I install Windows on the second drive? I guess the question really is, does Windows recognize the RAID card? I know it's probably just a rebadged LSI or Adaptec but wanted to see if anyone's actually done it...

    Read the article

  • windows-2003 server SCSI driver problem

    - by Vicky
    I have a problem in Adaptec 160m SCSI card connected to DELL Power Edge server, that it is often stops communicating. In windows system error I am able to see an error pointing to the SCSI driver continuously. The error says: The driver detected a controller error on \Device\Scsi\adpu160m4. For more information, see Help and Support Center at http://go.microsoft.com/fwlink/events.asp. Can anyone suggest me what to do to solve it?

    Read the article

1 2  | Next Page >