  • Possible capacitor plague - need help identifying

    - by cornjuliox
    I've been having some PC power issues lately, and I think I've tracked it down to a bad power supply. Lately, when I'm on my PC it will often restart without warning, displaying "Hypertransport sync flood error occurred last boot." once POST finishes. I've googled the error, but can't come to a definitive conclusion as to what's causing it. I've seen posts suggesting that it might be a power supply issue, but nothing conclusive. Here's what I've done so far: -I haven't installed anything suspect within the last 3 months. -I do overclock just a tiny bit, so I tried raising the voltages a little. That didn't work so I brought both CPU multiplier and voltages all back to their default settings, but that didn't solve the problem either. The problem still occurs. -AV scanned the whole system, nothing suspect. -I suspected that it might be a bad power supply so I cracked that open and found the following: I think it might be cap plague, but I'm not sure. It looks more like glue TBH. Could someone help me figure out what might be wrong with this PC? EDIT: Sometimes, after these restarts, I noticed that the GPU fan doesn't spin up, and the single rear case fan that just happens to be connected to the same molex Y-cable as the GFX card doesn't spin up either. Anything to that? EDIT 2: I do use the system quite heavily, but I don't know how that will factor into this. I often play Diablo 3 and EVE Online at the same time, frequently alt-tabbing between the two. I also have Firefox open in the background, sometimes with several tabs, and if I feel like it, I'll mute the in-game sound and open foobar2000 for better music. Could it be that I'm just pushing this thing too hard? EDIT 3: I also noticed something odd. Right before I experience these restarts, my monitor would suffer from very faint lines of static moving across the screen. The monitor is still very much useable, but it is very annoying. Following the restart it disappears, and then would gradually re-appear over the next few days, and then restarts again. I find it to be very odd. System specs for good measure: Orion 600 W PSU AMD Athlon II X3 440 (overclocked to 3.14 ghZ, raised the CPU multiplier to x13 from x10) MSI G40-775 motherboard 1 GB inno3D GTX 550 ti 4 GB DDR3 RAM 500 GB Samsung SATA HD

    Read the article

  • Flash Backed Write Cache (FBWC) without capacitor pack

    - by Martyn
    I brought a HP Smart Array P410 controller and it is installed and working fine in a HP Prolient Microserver with 4 drives in two RAID 1 arrays. I didn’t realise however that it came without any cache so would only work by directly writing straight to the disk, and the performance was horrible. So I then brought the 512MB Flash Backed Write Cache (FBWC) memory module as I was under the impression that with FBWC I would not need a battery. I got this idea from a forum post. "What do you guys think of the choice between 'BBWC' (battery backed write cache) and 'FBWC' (flash backed write cache)? The flashed based ones use non-volitile memory so need no battery." After installing the cache module however the server pretty much won’t boot. The P410 has a flashing amber light on it, and from the manual that doesn’t sound good. I’ve managed to get to the on board BIOS once and even managed to get to boot to the HP Array Configuration Utility (ACU) CD once, but every other time the Server continuingly reboots once it get to the POST screen and reads ARRAY INITILIZING %%%. The one time I reached the ACU, it reported a problem with the Cache Module. To me, it seems like the cache module is faulty, however the supplier tells me “Do you have an FBWC battery pack, p/n 587324-001, because that is required for the cache to work. If you have it, please complete an RMA form and we'll send a replacement / credit.” Does this sound right to you? I’ve been ordering the parts from the US and I don’t want to spend $77 + $40 p&p on a battery, wait a week for the shipping to find the card is faulty, and I don’t want to send back a working card?

    Read the article

  • How long until the chirping stops or what can I do to make it stop?

    - by MadBurn
    I know computers, I have been fixing them and building them for over a decade... but I don't know the exact electronics of them. My personal desktop PC is making an irregular, but constant, extremely high pitched chirping noise. I know this could be my hard drive, but I've heard that noise before and I believe this is a capacitor or part of the electronics. This noise is right at the edge of my hearing and I can feel it more than I can hear it. After a while, it starts to give me a headache and makes me physically sick. How long will this last? Is there anything I can do to fix it (short of replacing the entire motherboard)?

    Read the article

  • Proper multimeter specs for fixing capacitors on your motherboard?

    - by Xeoncross
    When our motherboards or LCD's go out it is possible that the capacitors are at fault and can be easily replaced by removing and replacing the bad caps rather than buying new screens or computers. After all, replacing a cap is much faster than building a new PC. Along those lines some of the capacitors I see on my boards are over 900µF. What is the bare minimum you need in a multimeter to test for bad capacitors (or good capacitance?)

    Read the article

  • Computer not working, motherboard is suspect

    - by Arlen Beiler
    I have a problem with my computer. I have a GeForce 6100 M9 Motherboard, which I suspect is broke. The capacitors beside the CPU are corroded and the computer doesn't do anything except start the fans when I push the power button. The problem is that I can't find another motherboard as they apparently don't sell this model anymore. I have tested the Power Supply and it appears to be working. Any advice would be appreciated. Different forums have mentioned that you can replace the capacitors. Any help on this would be appreciated.

    Read the article

  • How do I get access to object being described?

    - by Bill T
    If I have an example such as the following: describe "A flux capacitor" do it "should flux a lot" do # how can I access the string object "A flux capacitor" in here??? ... end end How can I access the described string object "A flux capacitor"? I've tried a few permutations of 'described_type' and 'described_class' Such as: self.described_type.to_s But these always return nothing. What am I doing wrong? Thanks, -Bill

    Read the article

  • How cpu writes data to dynamic RAM

    - by Krit
    Hello, I would like to know what kind of electrical signals does a cpu send to a dynamic RAM when it wants to write one bit (a 1 or 0). Is it simply that cpu sends just a single electric pulse, and if that electric pulse's voltage is higher than a certain level, it charges the capacitor to a voltage level that is "1" and if it is at a lower voltage band, it charges capacitor to level that it is "0"?

    Read the article

  • Fortran: output format dependent on a variable

    - by Flux Capacitor
    I would like to have a FORTRAN write statement formatted to depend on some variable. For example, I could write: write(*,'(3f15.3,3f9.2)') x,y,z,(var(i),i=1,nvari) where nvari = 3 But, what if, in some cases, I actually have 4 variables (i.e. nvari = 4) I would like to write something like this: write(*,'(3f15.3,nvari(f9.2))') x,y,z,(var(i),i=1,nvari) Now, nvari can be anything and the output will work as I like. How can I make something like this work?

    Read the article

  • stock management of assemblys and its sub parts

    - by The Disintegrator
    I have to track the stock of individual parts and kits (assembly) and can't find a satisfactory way of doing this. Sample bogus and hyper simplified database: Table prod: prodID 1 prodName Flux capacitor prodCost 900 prodPrice 1350 (900*1.5) prodStock 3 - prodID 2 prodName Mr Fusion prodCost 300 prodPrice 600 (300*2) prodStock 2 - prodID 3 prodName Time travel kit prodCost 1650 (1350+300) prodPrice 2145 (1650*1.3) prodStock 2 Table rels relID 1 relSrc 1 (Flux capacitor) relType 4 (is a subpart of) relDst 3 (Time travel kit) - relID 2 relSrc 2 (Mr Fusion) relType 4 (is a subpart of) relDst 3 (Time travel kit) prodPrice: it's calculated based on the cost but not in a linear way. In this example for costs of 500 or less, the markup is a 200%. For costs of 500-1000 the markup is 150%. For costs of 1000+ the markup is 130% That's why the time travel kit is much cheaper than the individual parts prodStock: here is my problem. I can sell kits or the individual parts, So the stock of the kits is virtual. The problem when I buy: Some providers sell me the Time Travel kit as a whole (with one barcode) and some sells me the individual parts (with a different barcode) So when I load the stock I don't know how to impute it. The problem when I sell: If I only sell kits, calculate the stock would be easy: "I have 3 Flux capacitors and 2 Mr Fusions, so I have 2 Time travel kits and a Flux Capacitor" But I can sell Kits or individual parts. I have to track the stock of the individual parts and the possible kits at the same time (and I have to compensate for the sell price) Probably this is really simple, but I can't see a simple solution. Resuming: I have to find a way of tracking the stock and the database/program is the one who has to do it (I cant ask the clerk to correct the stock) I'm using php+MySql. But this is more a logical problem than a programing one

    Read the article

  • Stock management of assemblies and its sub parts

    - by The Disintegrator
    I have to track the stock of individual parts and kits (assemblies) and can't find a satisfactory way of doing this. Sample bogus and hyper simplified database: Table prod: prodID 1 prodName Flux capacitor prodCost 900 prodPrice 1350 (900*1.5) prodStock 3 - prodID 2 prodName Mr Fusion prodCost 300 prodPrice 600 (300*2) prodStock 2 - prodID 3 prodName Time travel kit prodCost 1650 (1350+300) prodPrice 2145 (1650*1.3) prodStock 2 Table rels relID 1 relSrc 1 (Flux capacitor) relType 4 (is a subpart of) relDst 3 (Time travel kit) - relID 2 relSrc 2 (Mr Fusion) relType 4 (is a subpart of) relDst 3 (Time travel kit) prodPrice: it's calculated based on the cost but not in a linear way. In this example for costs of 500 or less, the markup is a 200%. For costs of 500-1000 the markup is 150%. For costs of 1000+ the markup is 130% That's why the time travel kit is much cheaper than the individual parts prodStock: here is my problem. I can sell kits or the individual parts, So the stock of the kits is virtual. The problem when I buy: Some providers sell me the Time Travel kit as a whole (with one barcode) and some sells me the individual parts (with a different barcode) So when I load the stock I don't know how to impute it. The problem when I sell: If I only sell kits, calculate the stock would be easy: "I have 3 Flux capacitors and 2 Mr Fusions, so I have 2 Time travel kits and a Flux Capacitor" But I can sell Kits or individual parts. So, I have to track the stock of the individual parts and the possible kits at the same time (and I have to compensate for the sell price) Probably this is really simple, but I can't see a simple solution. Resuming: I have to find a way of tracking the stock and the database/program is the one who has to do it (I cant ask the clerk to correct the stock) I'm using php+MySql. But this is more a logical problem than a programing one

    Read the article

  • Stock management of assemblies and its sub parts (relations)

    - by The Disintegrator
    I have to track the stock of individual parts and kits (assemblies) and can't find a satisfactory way of doing this. Sample bogus and hyper simplified database: Table prod: prodID 1 prodName Flux capacitor prodCost 900 prodPrice 1350 (900*1.5) prodStock 3 - prodID 2 prodName Mr Fusion prodCost 300 prodPrice 600 (300*2) prodStock 2 - prodID 3 prodName Time travel kit prodCost 1650 (1350+300) prodPrice 2145 (1650*1.3) prodStock 2 Table rels relID 1 relSrc 1 (Flux capacitor) relType 4 (is a subpart of) relDst 3 (Time travel kit) - relID 2 relSrc 2 (Mr Fusion) relType 4 (is a subpart of) relDst 3 (Time travel kit) prodPrice: it's calculated based on the cost but not in a linear way. In this example for costs of 500 or less, the markup is a 200%. For costs of 500-1000 the markup is 150%. For costs of 1000+ the markup is 130% That's why the time travel kit is much cheaper than the individual parts prodStock: here is my problem. I can sell kits or the individual parts, So the stock of the kits is virtual. The problem when I buy: Some providers sell me the Time Travel kit as a whole (with one barcode) and some sells me the individual parts (with a different barcode) So when I load the stock I don't know how to impute it. The problem when I sell: If I only sell kits, calculate the stock would be easy: "I have 3 Flux capacitors and 2 Mr Fusions, so I have 2 Time travel kits and a Flux Capacitor" But I can sell Kits or individual parts. So, I have to track the stock of the individual parts and the possible kits at the same time (and I have to compensate for the sell price) Probably this is really simple, but I can't see a simple solution. Resuming: I have to find a way of tracking the stock and the database/program is the one who has to do it (I cant ask the clerk to correct the stock) I'm using php+MySql. But this is more a logical problem than a programing one

    Read the article

  • Simple hardware RNG

    - by roygbiv
    I made a tongue-in-cheek comment to this question about making a hardware RNG. Does anyone know of any simple plans or can anyone descibe a simple hardware based RNG and the software to drive it? Go to Radio Shack. Buy a diode, an NTR resistor, a capacitor and serial cable. Cut off the end of the serial cable that does not fit on your computer. Solder the diode and resistor in series between pins DTR and DSR of the cable. Solder the capacitor between DSR and TXD pins. Write a small C program to do the following: Set DTR to 1. Start Timer. Monitor DSR until it goes to 1. Stop Timer. Calculate resistance from elapsed time. Retreive serveral bits from that value to use as part of random number. Repeat until enough bits have accumulated.

    Read the article

  • Is it possible to shrink the size of an HP Smart Array logical drive?

    - by ewwhite
    I know extension is quite possible using the hpacucli utility, but is there an easy way to reduce the size of an existing logical drive (not array)? The controller is a P410i in a ProLiant DL360 G6 server. I'd like to reduce logicaldrive 1 from 72GB to 40GB. => ctrl all show config detail Smart Array P410i in Slot 0 (Embedded) Bus Interface: PCI Slot: 0 Serial Number: 5001438006FD9A50 Cache Serial Number: PAAVP9VYFB8Y RAID 6 (ADG) Status: Disabled Controller Status: OK Chassis Slot: Hardware Revision: Rev C Firmware Version: 3.66 Rebuild Priority: Medium Expand Priority: Medium Surface Scan Delay: 3 secs Surface Scan Mode: Idle Queue Depth: Automatic Monitor and Performance Delay: 60 min Elevator Sort: Enabled Degraded Performance Optimization: Disabled Inconsistency Repair Policy: Disabled Wait for Cache Room: Disabled Surface Analysis Inconsistency Notification: Disabled Post Prompt Timeout: 15 secs Cache Board Present: True Cache Status: OK Accelerator Ratio: 25% Read / 75% Write Drive Write Cache: Enabled Total Cache Size: 512 MB No-Battery Write Cache: Disabled Cache Backup Power Source: Batteries Battery/Capacitor Count: 1 Battery/Capacitor Status: OK SATA NCQ Supported: True Array: A Interface Type: SAS Unused Space: 412476 MB Status: OK Logical Drive: 1 Size: 72.0 GB Fault Tolerance: RAID 1+0 Heads: 255 Sectors Per Track: 32 Cylinders: 18504 Strip Size: 256 KB Status: OK Array Accelerator: Enabled Unique Identifier: 600508B1001C132E4BBDFAA6DAD13DA3 Disk Name: /dev/cciss/c0d0 Mount Points: /boot 196 MB, / 12.0 GB, /usr 8.0 GB, /var 4.0 GB, /tmp 2.0 GB OS Status: LOCKED Logical Drive Label: AE438D6A5001438006FD9A50BE0A Mirror Group 0: physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 146 GB, OK) physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 146 GB, OK) Mirror Group 1: physicaldrive 1I:1:3 (port 1I:box 1:bay 3, SAS, 146 GB, OK) physicaldrive 1I:1:4 (port 1I:box 1:bay 4, SAS, 146 GB, OK) SEP (Vendor ID PMCSIERA, Model SRC 8x6G) 250 Device Number: 250 Firmware Version: RevC WWID: 5001438006FD9A5F Vendor ID: PMCSIERA Model: SRC 8x6G

    Read the article

  • Ways to make USB Firefox faster

    - by MichaelKay
    I have several laptops so I use a USB key version of Firefox to keep my environment as I move around. I followed the suggestions offered on the Firefox web site (turn off the cache and history etc.) and its better but still much slower than the normal version. Other than buying a new, super fast flux-capacitor based USB key, what other tips and tricks can I use?

    Read the article

  • Organization & Architecture UNISA Studies – Chap 5

    - by MarkPearl
    Learning Outcomes Describe the operation of a memory cell Explain the difference between DRAM and SRAM Discuss the different types of ROM Explain the concepts of a hard failure and a soft error respectively Describe SDRAM organization Semiconductor Main Memory The two traditional forms of RAM used in computers are DRAM and SRAM DRAM (Dynamic RAM) Divided into two technologies… Dynamic Static Dynamic RAM is made with cells that store data as charge on capacitors. The presence or absence of charge in a capacitor is interpreted as a binary 1 or 0. Because capacitors have natural tendency to discharge, dynamic RAM requires periodic charge refreshing to maintain data storage. The term dynamic refers to the tendency of the stored charge to leak away, even with power continuously applied. Although the DRAM cell is used to store a single bit (0 or 1), it is essentially an analogue device. The capacitor can store any charge value within a range, a threshold value determines whether the charge is interpreted as a 1 or 0. SRAM (Static RAM) SRAM is a digital device that uses the same logic elements used in the processor. In SRAM, binary values are stored using traditional flip flop logic configurations. SRAM will hold its data as along as power is supplied to it. Unlike DRAM, no refresh is required to retain data. SRAM vs. DRAM DRAM is simpler and smaller than SRAM. Thus it is more dense and less expensive than SRAM. The cost of the refreshing circuitry for DRAM needs to be considered, but if the machine requires a large amount of memory, DRAM turns out to be cheaper than SRAM. SRAMS are somewhat faster than DRAM, thus SRAM is generally used for cache memory and DRAM is used for main memory. Types of ROM Read Only Memory (ROM) contains a permanent pattern of data that cannot be changed. ROM is non volatile meaning no power source is required to maintain the bit values in memory. While it is possible to read a ROM, it is not possible to write new data into it. An important application of ROM is microprogramming, other applications include library subroutines for frequently wanted functions, System programs, Function tables. A ROM is created like any other integrated circuit chip, with the data actually wired into the chip as part of the fabrication process. To reduce costs of fabrication, we have PROMS. PROMS are… Written only once Non-volatile Written after fabrication Another variation of ROM is the read-mostly memory, which is useful for applications in which read operations are far more frequent than write operations, but for which non volatile storage is required. There are three common forms of read-mostly memory, namely… EPROM EEPROM Flash memory Error Correction Semiconductor memory is subject to errors, which can be classed into two categories… Hard failure – Permanent physical defect so that the memory cell or cells cannot reliably store data Soft failure – Random error that alters the contents of one or more memory cells without damaging the memory (common cause includes power supply issues, etc.) Most modern main memory systems include logic for both detecting and correcting errors. Error detection works as follows… When data is to be read into memory, a calculation is performed on the data to produce a code Both the code and the data are stored When the previously stored word is read out, the code is used to detect and possibly correct errors The error checking provides one of 3 possible results… No errors are detected – the fetched data bits are sent out An error is detected, and it is possible to correct the error. The data bits plus error correction bits are fed into a corrector, which produces a corrected set of bits to be sent out An error is detected, but it is not possible to correct it. This condition is reported Hamming Code See wiki for detailed explanation. We will probably need to know how to do a hemming code – refer to the textbook (pg. 188 – 189) Advanced DRAM organization One of the most critical system bottlenecks when using high-performance processors is the interface to main memory. This interface is the most important pathway in the entire computer system. The basic building block of main memory remains the DRAM chip. In recent years a number of enhancements to the basic DRAM architecture have been explored, and some of these are now on the market including… SDRAM (Synchronous DRAM) DDR-DRAM RDRAM SDRAM (Synchronous DRAM) SDRAM exchanges data with the processor synchronized to an external clock signal and running at the full speed of the processor/memory bus without imposing wait states. SDRAM employs a burst mode to eliminate the address setup time and row and column line precharge time after the first access In burst mode a series of data bits can be clocked out rapidly after the first bit has been accessed SDRAM has a multiple bank internal architecture that improves opportunities for on chip parallelism SDRAM performs best when it is transferring large blocks of data serially There is now an enhanced version of SDRAM known as double data rate SDRAM or DDR-SDRAM that overcomes the once-per-cycle limitation of SDRAM

    Read the article

  • Simpler Times

    - by Simon Moon
    Does anyone else out there long for the simpler days where you needed to move a jumper in the jumper block to set your modem card to use IRQ7 so it would not conflict with the interrupts used by other boards in your PC and your modem card came with a 78 page manual telling you everything you would need to know to write your own driver for the board including a full schematic along with the board layout showing every chip, capacitor, and resistor?  Ahhhhh, the simplicity!I am wrestling with UserPnp issues for a USB software licensing dongle that is needed by some third party software in one of our production applications. Of course, every machine in production is virtual, so it could be anything in the chain of the software application library to the device driver running on the VM to the configuration of the simulated USB port to the implementation of the USB connection and transport in the virtual host to the physical electrical connections in the USB port on the hypervisor.If only there were the virtual analog to a set of needle-nose pliers to move a virtual jumper.Come to think of it, I always used to drop those damn things such that they would land in an irretrievable position under the motherboard anyway.

    Read the article

  • HP SmartArray P400: How to repair failed logical drive?

    - by TegtmeierDE
    I have a HP Server with SmartArray P400 controller (incl. 256 MB Cache/Battery Backup) with a logicaldrive with replaced failed physicaldrive that does not rebuild. This is how it looked when I detected the error: ~# /usr/sbin/hpacucli ctrl slot=0 show config Smart Array P400 in Slot 0 (Embedded) (sn: XXXX) array A (SATA, Unused Space: 0 MB) logicaldrive 1 (698.6 GB, RAID 1, OK) physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SATA, 750 GB, OK) physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SATA, 750 GB, OK) array B (SATA, Unused Space: 0 MB) logicaldrive 2 (2.7 TB, RAID 5, Failed) physicaldrive 1I:1:3 (port 1I:box 1:bay 3, SATA, 750 GB, OK) physicaldrive 1I:1:4 (port 1I:box 1:bay 4, SATA, 750 GB, OK) physicaldrive 2I:1:5 (port 2I:box 1:bay 5, SATA, 750 GB, OK) physicaldrive 2I:1:6 (port 2I:box 1:bay 6, SATA, 750 GB, Failed) physicaldrive 2I:1:7 (port 2I:box 1:bay 7, SATA, 750 GB, OK) unassigned physicaldrive 2I:1:8 (port 2I:box 1:bay 8, SATA, 750 GB, OK) ~# I thought that I had drive 2I:1:8 configured as a spare for Array A and Array B, but it seems this was not the case :-(. I noticed the problem due to I/O errors on the host, even if only 1 physicaldrive of the RAID5 is failed. Does someone know why this could happen? The logicaldrive should go into "Degraded" mode but still be fully accessible from the host os!? I first tried to add the unassigned drive 2I:1:8 as a spare to logicaldrive 2, but this was not possible: ~# /usr/sbin/hpacucli ctrl slot=0 array B add spares=2I:1:8 Error: This operation is not supported with the current configuration. Use the "show" command on devices to show additional details about the configuration. ~# Interestingly it is possible to add the unassigned drive to the first array without problems. I thought maybe the controller put the array into "failed" state due to the missing spare and protects failed arrays from modification. So I tried was to reenable the logicaldrive (to add the spare afterwards): ~# /usr/sbin/hpacucli ctrl slot=0 ld 2 modify reenable Warning: Any previously existing data on the logical drive may not be valid or recoverable. Continue? (y/n) y Error: This operation is not supported with the current configuration. Use the "show" command on devices to show additional details about the configuration. ~# But as you can see, re-enabling the logicaldrive this was not possible. Now I replaced the failed drive by hotswapping it with the unassigned drive. The status now looks like this: ~# /usr/sbin/hpacucli ctrl slot=0 show config Smart Array P400 in Slot 0 (Embedded) (sn: XXXX) array A (SATA, Unused Space: 0 MB) logicaldrive 1 (698.6 GB, RAID 1, OK) physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SATA, 750 GB, OK) physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SATA, 750 GB, OK) array B (SATA, Unused Space: 0 MB) logicaldrive 2 (2.7 TB, RAID 5, Failed) physicaldrive 1I:1:3 (port 1I:box 1:bay 3, SATA, 750 GB, OK) physicaldrive 1I:1:4 (port 1I:box 1:bay 4, SATA, 750 GB, OK) physicaldrive 2I:1:5 (port 2I:box 1:bay 5, SATA, 750 GB, OK) physicaldrive 2I:1:6 (port 2I:box 1:bay 6, SATA, 750 GB, OK) physicaldrive 2I:1:7 (port 2I:box 1:bay 7, SATA, 750 GB, OK) ~# The logical drive is still not accessible. Why is it not rebuilding? What can I do? FYI, this is the configuration of my controller: ~# /usr/sbin/hpacucli ctrl slot=0 show Smart Array P400 in Slot 0 (Embedded) Bus Interface: PCI Slot: 0 Serial Number: XXXX Cache Serial Number: XXXX RAID 6 (ADG) Status: Enabled Controller Status: OK Chassis Slot: Hardware Revision: Rev E Firmware Version: 5.22 Rebuild Priority: Medium Expand Priority: Medium Surface Scan Delay: 15 secs Surface Analysis Inconsistency Notification: Disabled Raid1 Write Buffering: Disabled Post Prompt Timeout: 0 secs Cache Board Present: True Cache Status: OK Accelerator Ratio: 25% Read / 75% Write Drive Write Cache: Disabled Total Cache Size: 256 MB No-Battery Write Cache: Disabled Cache Backup Power Source: Batteries Battery/Capacitor Count: 1 Battery/Capacitor Status: OK SATA NCQ Supported: True ~# Thanks for you help in advance.

    Read the article

  • Can't Remove Logical Drive/Array from HP P400

    - by Myles
    This is my first post here. Thank you in advance for any assistance with this matter. I'm trying to remove a logical drive (logical drive 2) and an array (array "B") from my Smart Array P400. The host is a DL580 G5 running 64-bit Red Hat Enterprise Linux Server release 5.7 (Tikanga). I am unable to remove the array using either hpacucli or cpqacuxe. I believe it is because of "OS Status: LOCKED". The file system that lives on this array has been unmounted. I do not want to reboot the host. Is there some way to "release" this logical drive so I can remove the array? Note that I do not need to preserve the data on logical drive 2. I intend to physically remove the drives from the machine and replace them with larger drives. I'm using the cciss kernel module that ships with Red Hat 5.7. Here is some information pertaining to the host and the P400 configuration: [root@gort ~]# cat /etc/redhat-release Red Hat Enterprise Linux Server release 5.7 (Tikanga) [root@gort ~]# uname -a Linux gort 2.6.18-274.el5 #1 SMP Fri Jul 8 17:36:59 EDT 2011 x86_64 x86_64 x86_64 GNU/Linux [root@gort ~]# rpm -qa | egrep '^(hp|cpq)' cpqacuxe-9.30-15.0 hp-health-9.25-1551.7.rhel5 hpsmh-7.1.2-3 hpdiags-9.3.0-466 hponcfg-3.1.0-0 hp-snmp-agents-9.25-2384.8.rhel5 hpacucli-9.30-15.0 [root@gort ~]# hpacucli HP Array Configuration Utility CLI 9.30.15.0 Detecting Controllers...Done. Type "help" for a list of supported commands. Type "exit" to close the console. => ctrl all show config detail Smart Array P400 in Slot 0 (Embedded) Bus Interface: PCI Slot: 0 Cache Serial Number: PA82C0J9SVW34U RAID 6 (ADG) Status: Enabled Controller Status: OK Hardware Revision: D Firmware Version: 7.22 Rebuild Priority: Medium Expand Priority: Medium Surface Scan Delay: 15 secs Surface Scan Mode: Idle Wait for Cache Room: Disabled Surface Analysis Inconsistency Notification: Disabled Post Prompt Timeout: 0 secs Cache Board Present: True Cache Status: OK Cache Ratio: 25% Read / 75% Write Drive Write Cache: Disabled Total Cache Size: 256 MB Total Cache Memory Available: 208 MB No-Battery Write Cache: Disabled Cache Backup Power Source: Batteries Battery/Capacitor Count: 1 Battery/Capacitor Status: OK SATA NCQ Supported: True Logical Drive: 1 Size: 136.7 GB Fault Tolerance: RAID 1 Heads: 255 Sectors Per Track: 32 Cylinders: 35132 Strip Size: 128 KB Full Stripe Size: 128 KB Status: OK Caching: Enabled Unique Identifier: 600508B100184A395356573334550002 Disk Name: /dev/cciss/c0d0 Mount Points: /boot 101 MB, /tmp 7.8 GB, /usr 3.9 GB, /usr/local 2.0 GB, /var 3.9 GB, / 2.0 GB, /local 113.2 GB OS Status: LOCKED Logical Drive Label: A0027AA78DEE Mirror Group 0: physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 146 GB, OK) Mirror Group 1: physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 146 GB, OK) Drive Type: Data Array: A Interface Type: SAS Unused Space: 0 MB Status: OK Array Type: Data physicaldrive 1I:1:1 Port: 1I Box: 1 Bay: 1 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 146 GB Rotational Speed: 10000 Firmware Revision: HPDE Serial Number: 3NM57RF40000983878FX Model: HP DG146BB976 Current Temperature (C): 29 Maximum Temperature (C): 35 PHY Count: 2 PHY Transfer Rate: Unknown, Unknown physicaldrive 1I:1:2 Port: 1I Box: 1 Bay: 2 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 146 GB Rotational Speed: 10000 Firmware Revision: HPDE Serial Number: 3NM55VQC000098388524 Model: HP DG146BB976 Current Temperature (C): 29 Maximum Temperature (C): 36 PHY Count: 2 PHY Transfer Rate: Unknown, Unknown Logical Drive: 2 Size: 546.8 GB Fault Tolerance: RAID 5 Heads: 255 Sectors Per Track: 32 Cylinders: 65535 Strip Size: 64 KB Full Stripe Size: 256 KB Status: OK Caching: Enabled Parity Initialization Status: Initialization Completed Unique Identifier: 600508B100184A395356573334550003 Disk Name: /dev/cciss/c0d1 Mount Points: None OS Status: LOCKED Logical Drive Label: A5C9C6F81504 Drive Type: Data Array: B Interface Type: SAS Unused Space: 0 MB Status: OK Array Type: Data physicaldrive 1I:1:3 Port: 1I Box: 1 Bay: 3 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 146 GB Rotational Speed: 10000 Firmware Revision: HPDE Serial Number: 3NM2H5PE00009802NK19 Model: HP DG146ABAB4 Current Temperature (C): 30 Maximum Temperature (C): 37 PHY Count: 1 PHY Transfer Rate: Unknown physicaldrive 1I:1:4 Port: 1I Box: 1 Bay: 4 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 146 GB Rotational Speed: 10000 Firmware Revision: HPDE Serial Number: 3NM28YY400009750MKPJ Model: HP DG146ABAB4 Current Temperature (C): 31 Maximum Temperature (C): 36 PHY Count: 1 PHY Transfer Rate: 3.0Gbps physicaldrive 2I:1:5 Port: 2I Box: 1 Bay: 5 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 146 GB Rotational Speed: 10000 Firmware Revision: HPDE Serial Number: 3NM2FGYV00009802N3GN Model: HP DG146ABAB4 Current Temperature (C): 30 Maximum Temperature (C): 38 PHY Count: 1 PHY Transfer Rate: Unknown physicaldrive 2I:1:6 Port: 2I Box: 1 Bay: 6 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 146 GB Rotational Speed: 10000 Firmware Revision: HPDE Serial Number: 3NM8AFAK00009920MMV1 Model: HP DG146BB976 Current Temperature (C): 31 Maximum Temperature (C): 41 PHY Count: 2 PHY Transfer Rate: Unknown, Unknown physicaldrive 2I:1:7 Port: 2I Box: 1 Bay: 7 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 146 GB Rotational Speed: 10000 Firmware Revision: HPDE Serial Number: 3NM2FJQD00009801MSHQ Model: HP DG146ABAB4 Current Temperature (C): 29 Maximum Temperature (C): 39 PHY Count: 1 PHY Transfer Rate: Unknown

    Read the article

  • graphics-card makes sound-card produce a buzzing sound

    - by Markus von Broady
    Recently I bought a new GPU: GeForce GTX 550 Ti, and after installing it I get a strange buzzing sound. It's not always there, just sometimes (mostly when I open some game, but sometimes also in browsers etc.). It's not a capacitor or a fan, as unplugging speakers from sound-card makes the 'bzzzzzzz' go away. However, muting windows doesn't mute this sound. I'm pretty sure it is fault of the new GPU, but how is this happening and can I fix it? Can it be a low power supply? I thought of buying a stronger unit, but as everything works, and computer doesn't shut down, I hesitate.

    Read the article

  • Monitor turns off about 1 second after turning it on

    - by r0ca
    Hi all! I have a hardware issue with some of the LCD monitors we have in our office. My problems is not related to video cards or anything else with the computer itself. I have 2 Dell 17" LCD screens that goes off (blank) after 1 or 2 seconds. The light remains green so it's not idling or sleeping. Just this morning, I had to replace one that goes off on 2 workstations and also on my laptop. Nothing to do with it. I tried the VGA and DVI connection w/out luck. I strongly think that this is something with a capacitor or something inside the screen but I can't figure out what it is... Is anybody heard of that kind of issue before? Regards, David.

    Read the article

  • Computer won't start unless power is removed for ~5 minutes

    - by Paul Tarjan
    I have a fairly standard 2-year old desktop computer (quad-core intel, single hard drive, decent video card, 300W power supply) which recently started acting up. I'm not sure what the cause is, so hopefully you can help. Sometimes (once a week-ish) I press the power button and nothing happens. No blinking, no sounds, no nothing. If I remove the power cord (or flip the switch on the power supply) I hear a capacitor discharge. If I leave it in the "no power at all" state for about 5 minutes then I can put the plug back in and the computer works perfectly. What is the issue? What do you think I have to replace?

    Read the article

  • Computer won't start unless power is removed for ~5 minutes

    - by Paul Tarjan
    I have a fairly standard 2-year old desktop computer (quad-core intel, single hard drive, decent video card, 300W power supply) which recently started acting up. I'm not sure what the cause is, so hopefully you can help. Sometimes (once a week-ish) I press the power button and nothing happens. No blinking, no sounds, no nothing. If I remove the power cord (or flip the switch on the power supply) I hear a capacitor discharge. If I leave it in the "no power at all" state for about 5 minutes then I can put the plug back in and the computer works perfectly. What is the issue? What do you think I have to replace?

    Read the article

  • My 386sx refuses to start in cold days

    - by Armadillo
    My old computer refuses to start in cold days. So, in really hot days (about 40ºC / 104ºF ) or even hotter, this PC usually starts, but in cold days, it wont. When the temperature is not in the "sweet-spot" the power light turns on for an half a second and then the computer turns off. But when it's really cold, not even the power light turns on, nor even a blink. Sometimes I use an Hair dryer, pointed directly to the PSU and that works great. 5 to 10 minutes is enough, depending on the ambient temperature. I think something is going wrong in my AT power supply. I can't replace this PSU for another because it has a non-standard size and connectors to power the motherboard. Does anybody have a clue about what it's failing in my PSU, so I can change that component (resistor, capacitor, ??, etc) and rock on with my 80386? Thanks

    Read the article

  • What are some funny loading statements to keep users amused?

    - by Oli
    Nobody likes waiting but unfortunately in the Ajax application I'm working on at the moment, there is one fair-sized pause (1-2 seconds a go) that users have to undergo each and every time they want to load up a chunk of data. I've tried to make the load as interactive as possible. There's an animated GIF alongside a very plain, very dull "Loading..." message. So I thought it might be quite fun to come up with a batch of 50-or-so funny-looking messages and pick from them randomly so the user never knows what they're going to see. The time they would have spent growing impatient is fruitfully used. Here's what I've come up with so far, just to give you an idea. var randomLoadingMessage = function() { var lines = new Array( "Locating the required gigapixels to render...", "Spinning up the hamster...", "Shovelling coal into the server...", "Programming the flux capacitor" ); return lines[Math.round(Math.random()*(lines.length-1))]; } (Yes -- I know some of those are pretty lame -- That's why I'm here :) The funniest I see today will get the prestigious "Accepted Answer" award. Others get votes for participation. Enjoy!!

    Read the article

  • Power cycles on/off 3 times before booting properly from cold start, no other issues (New System)

    - by James
    Relevant Specs: Sapphire 5850, core i7 920, Seasonic x750 power supply, ECS X58B-A2 mobo. From a cold boot, meaning all power totally disconnected at the wall, the system will power on for less than a second and then power off completely. After two seconds of being powered off this will repeat and on the third "attempt" the computer will boot. To be very specific here is what happens: The power is turned on at the wall and on the psu, the orange stdby LED on the mobo is illuminated but the system is 'off'. I hit the power button on the case or on the mobo itself I hear the relay (?) in the psu closing The case light comes on and the mobo power light comes on. The fans start rotating. Immediately after this the I hear some relay click - the power lights extinguish, the fans stop, the stdby light remains on. Less than 2 seconds pass and the cycle repeats without any intervention from me. On the third attempt it boots normally and the machine runs perfectly. If I do a soft reboot or a full shutdown the computer starts normally the next time. It's only if I pull the power cord or flick the switch off on the PSU that I get the cycling again. Basically any time the stdby light on the mobo goes out. I have removed the graphics card and I get the same problem. I have removed the PSU, hotwired it to the ON position and verified voltages on all lines. The relay does not cycle when I do this. If I connect only the 24 pin ATX connector to the mobo and not the 8 pin ATX12V / CPU connector then I will not get the cycling, the fans run, the power light stays on, but obviously the system can't boot. Disconnecting all fans has no effect on the problem. My feeling it that it's something to do with the motherboard like a capacitor that's taking a long time to charge because it's leaking or something along those lines. But I can't imagine what could be 'wrong' with it and only manifest itself as a problem under these very specific circumstances. Any ideas? Thanks.

    Read the article