Search Results

Search found 21 results on 1 pages for 'idrac'.

Page 1/1 | 1 

  • Restrict IPMI access on Dell BMC and iDRAC to an allowed IP range

    - by edgester
    I'm trying to secure the iDRAC's and BMC's on some of my Dell servers (R210, R410, R510). I want to restrict access to IPMI commands to only a few IP addresses. I've successfully restricted access to the iDrac using the instructions from http://support.dell.com/support/edocs/software/smdrac3/idrac/idrac10mono/en/ug/html/racugc2d.htm#wp1181529 , but the IP restrictions do not affect IPMI. A separate management network is not practical at this time because of lack or ports and some Dell BMC's don't offer a separate port. I'm told by my networking group that our switches don't support trunking, so using the vlan tagging is not an option either. Is there a way restrict the IPMI access to a list of allowed addresses? FYI, for various reasons, I have a mix of Dell servers with BMC's, iDrac Express and iDrac enterprise management features.

    Read the article

  • How to use auto-discovery with iDRAC Enterprise?

    - by jwiz
    All I want to do is: have "auto discovery" enabled on my iDRAC enterprise at the factory rack the server, cable iDRAC to dhcp-enabled management network have the iDRAC DHCP, find the "Provisioning Server", and get updated with login credentials (for us to use with racadm, idrac webui, etc.) I don't need to do any configuring of the system, install OS, or anything else. I just want idrac to dhcp out of the box, and end up with an account that can be used to login. All the docs I can find on Dell's site refer to a "Provisioning Server", but I honestly can't tell if they have some reference product, or if they only have software that "integrates" with other vendor's existing management systems. I'd be happy to set up whatever is needed, I just can't find something that explicitly describes the process (only references to the fact that it is supported).

    Read the article

  • Best Practice: iDRAC & NIC Selection

    - by Josh Brower
    I am setting up a new Dell server with iDRAC 6 Express. My options for the NIC are: 1) Shared 2) Shared with failover to LOM2 3) Shared with failover to all LOMs The server has 2x dual-nic PCI-E cards (total of 4 nics) My questions are thusly: -What is best practice for setting this up? Is there any reason why I would not want option 3? -If the NIC is being used for both iDRAC and the OS, (there is no dedicated iDRAC nic), does this ever cause any kinds of issues for either iDRAC or the OS? Thanks- -Josh

    Read the article

  • iDRAC on Dell R710 and R720

    - by BT643
    I've called Dell twice to try and clarify this basic (or so I thought) question, but I've had two different answers so far. We have a Dell R710, and a Dell R720. Does DRAC come installed by default on either? Dell said it comes build into the motherboard on the R720 but the second time I rang, they said we didn't have it. Can anyone tell me if DRAC comes as standard on the R720? I'm aware we'll need a license as well, I'm just interested in the physical capability on the server. I've never used DRAC before and know next to nothing about it, so apologies if this seems blindingly simple. Thanks

    Read the article

  • Set iDRAC IP Address on Ubuntu 12.04 without Reboot?

    - by BT643
    We have a Dell PowerEdge R720XD server and want to setup iDRAC, but this is a production server so we need to do it without a reboot if possible. We just need to set the IP address on the iDRAC but the servers do not have a front LCD panel so we cannot use this. The iDRAC will currently have the default 192.168.0.120 IP address but we are not on this IP range so cannot use this. We need to change it to 192.168.5.x. I've seen racadm mentioned, but before I start messing around installing this on Ubuntu, is this what we need? and will we be able to set the IP address on the DRAC with this? Thanks

    Read the article

  • Dell OpenManage iDrac

    - by mhouston100
    I have installed OpenManage Server Administrator on a Windows 7 workstation with the assumption that nothing needed to be done on the actual server I am trying to manage. The server has an iDrac v7 component and I was under the impression that OpenManage just connects to that? When I try to connect I put the IP address of the iDrac console and the username/password and I get a 'Connection Error' message. So my question, does OpenManage have to be installed on the server that is to be managed, even if it has a DRAC connection?

    Read the article

  • Dell PE R710 Lifecycle Controller

    - by rihatum
    Hi All, How would one use the dell lifecycle controller on the new R710 Servers ? I have seen demos on youtube and it can install linux, windows from there without inserting the installation discs ? I am on the same LAN as the server and have setup iDrac Express (we dont have drac enterprise). Any suggestions ? Thanks

    Read the article

  • Server 2008 R2 repair install

    - by Kyle
    Is it possible to do a repair install on a server 2008 R2 Enterprise machine like we used to be able to do on 2003? I need to reinstall on a remote server and don't have a driver cd in the drive just a copy of server. I am worried that when it comes back up I won't have any drivers for the NIC. I have a iDRAC but can't seem to send files over the DRAC to the machine. Sadly this server doesn't have an SD card in the DRAC with the files I need. I welcome any suggestions if the repair is not possible. Our IDC is in Chicago and they are buried under snow so I won't be able to get another admin on site until at least tomorrow.

    Read the article

  • Using a Dell DRAC virtual console through a NAT firewall

    - by jetboy
    I have two Dell Poweredge R210 servers, both running Ubuntu 10 Server x64. Server A has a Dell DRAC ILO card (on 172.16.96.91), and both the server and the DRAC use Server B as a gateway (with server B's WAN IP being xxx.xxx.xxx.xx). Server B uses the following NAT rules in IPTables to route traffic through to Server A's DRAC: *NAT --append PREROUTING --in-interface eth1 --protocol tcp --destination xxx.xxx.xxx.xx --destination-port 8019 --jump DNAT --to-destination 172.16.96.91:443 --append POSTROUTING --out-interface eth1 --jump SNAT --to-source xxx.xxx.xxx.xx This works fine for accessing Server A's DRAC via Server B, apart from the Java virtual console. This fails with the following error: com.sun.deploy.net.FailedDownloadException: Unable to load resource: https://xxx.xxx.xxx.xx:443/software/avctKVM.jar at com.sun.deploy.net.DownloadEngine.actionDownload(Unknown Source) etc. I know that the Java console uses port 5900, and possibly ports 83 and 5891. Can anyone help me in getting this working?

    Read the article

  • Cannot start serial over lan on iDrac6

    - by Bryan Agee
    I have a couple of Dell R610/R710 servers loaded with iDrac6 system management boards. I figured out how to log into the SM CLP with ssh. According to the dell documentation, I should be able to start a console session by running: start /system1/sol1 but I get the following failure message: cmdstat status : 3 status_tag : COMMAND EXECUTION FAILED job job_id : 12 joberr errtype : 1 errtype_desc : Other cimstat : 6 cimstat_desc : CIM_ERR_NOT_FOUND severity : 2 severity_desc : Low /system1/sol1 started FAILED at Sun Sep 16 00:20:58 2012 I have enabled the serial-over-lan via the web interface and rebooted, but nothing seems to make them available.

    Read the article

  • Is there a way to obtain a Dell server's RAID configuration/level using only winrm/wsman? (ESXi servers)

    - by EGr
    I've seen videos describing how to configure RAID using wsman/winrm commands run against a server's iDRAC, but I can't seem to find anything that will just give me the current configuration and RAID levels. Is this possible? What uri would I use? If it matters, this is being run against M610s. Edit: If there is an easier way to obtain this information by running a script against the iDRAC, I'm not opposed to switching my methods. EDIT: The server is running ESXi, so if there is a way to obtain this through the vSphere client or PowerCLI, I can do that too. Overall, I just need a way to obtain the RAID configuration for multiple servers without having to query against the actual server (eg: via the iDRAC).

    Read the article

  • Moving Farm to co-location hosting - network settings requirements

    - by Saariko
    I am moving my farm (2 Dell's R620) to a co-location hosting service. I am trying to figure out the secure way to have my network settings The requirements are: VM1 is the working HOST, includes: esxi 5.1, vSphere, 4 clients (w2008r2 all) VM2 has esxi 5.1 installed, and a single machine with Veeam Backup and copy 6.5 - keeping a copy of VM1 clients on the VM2 internal storage (this solution is due to a very small budget - in case of failure on Host 1 - can redirect IP's) Only 2 VM clients require network address and access from the WWAN - ISP provides IP's range for them (with Gateway and DNS) I need connection to the iDrac's from my office (option to create a VPN-SSL tunnel) Connection to the vSphere appliances I want to be able to RDP to the VM clients The current configuration is that each host has the iDrac dedicated nic connected , and another (NIC #1) connected - with a static IP on 192.168.3.x The iDrac's have a static IP from the same network range (19.168.3.x) It will look something like this: My thoughts: On NIC#2 of both hosts I will connected a crossed cable I will give each VM clients that needs internet access a 2ndry VM network with the assigned IP from the ISP open only to web - can not access from the My Question: Should I give IP's (external) to the machines who DO NOT require WWAN Access? - I can't see a way to RDP to them directly if not. Should I use the crossed cable? or just plug NIC #2 to the switch? Will this setup even work? What do I need to verify? What Virtual nic's and/or switches should I create on the Hosts?

    Read the article

  • Provisioning DELL servers using only linux tools

    - by Krist van Besien
    We have taken delivery of a bunch off Dell Poweredge Rack servers. Unfortunately when ordering it was neglegted to ask for dhcp to be enabled in the built in iDRAC controlers... So they are all stuck on the same IP address. Which means that I'll have to go to each of them individually and configure a new IP in the console... In the future I want to avoid that. Now Dell proposes to deliver the next batch with auto discovery enabled. As I understand this means that when the machine wakes up for the first time the iDRAC will request a DHCP address. The DHCP server then supposedly also provides a "provisioning" server, that provides it with a username and password, and a configuration to be applied. This would allow us to for example configure things like RAID automatically. However, I can't seem to find a way to set up such a provisioning server that does not involve setting up a windows machine. I want to use Linux tools exclusively. Is there a way to do this? I want to just rack servers, switch them on, and then do everything remotely. And that using only linux tools?

    Read the article

  • Creating rescue / install USB flash disk for CentOS

    - by wwwpanda
    For CentOS installation CDs, you can install OS, as well as booting into "rescue" mode so that you can do a chroot mount on the system partition for problem solving, even the system is installed in hardware RAID drives. How can we create a similar thing but on usb flash drive? I tried to do it with unetbootin, but when booting into the USB, eventually the CentOS setup still requires presence of CDs. Ultimately, I want to use this usb flash drive for remote disaster recovery through say HP iLo remote console / Dell iDrac etc.

    Read the article

  • Upgrade to Precise leaving system unbootable

    - by Talemon
    I've upgraded our server's system from Lucid to Precise and as far as I can tell, it left the system in an un-bootable state. I've read many responses in different threads but my problem has a twist. When we boot the server, it says The disc drive for / is not ready yet or not present Continue to wait; or press S to skip mounting or M for manual recovery but when I press any of those buttons, it doesn't do anything. I can't boot to any recovery console, and as it is a server and I'm accessing it via iDRAC, there's not much I can do.

    Read the article

  • Dell PowerEdge R720xd stuck in BIOS

    - by G_P
    I have a Dell PowerEdge R720xd that gets stuck in the BIOS when booting. It successfully gets past the "configuring memory" and "configuring iDRAC" screens, but once it shows the "CPLD version : 103" with the various management engine versions/patches, it just hangs. No errors messages are displayed. This started happening when we tried adding additional RAM to the machine. Since then, we tried re-seating the new memory which resulted in the same issue. Then, we took out all the new memory, and the problem persists. We have also tried pressing F2 to get into System Setup, but it just indicates "Entering System Setup" and hangs at the same point. Has anybody seen this issue before or have any ideas on what to try next? UPDATE After troubleshooting and trying to isolate the issue (stripping things down to a single CPU and single DIMM, same problem, swapping to the other CPU and a different DIMM, same problem), Dell support will be coming out to swap the system board.

    Read the article

  • NIC light is turned off after boot on Redhat 4.6 server

    - by hoffmandirt
    I have a 2950 blade server setup with Red Hat 4.6 installed. I cannot get the NIC to work properly after reinstalling Linux. I activated the NIC, but the NIC light will not turn on when I plug the network cable into the hub. The status light on the hub will not turn on either. If I run ifconfig, the NIC status is UP. Also I can ping the IP address that I assign to the Linux machine, but I can't ping anything else that is plugged into the hub. When I reboot the system, the NIC light will stay on until the system fully boots and then it will turn off again. Is there something else that I need to do to get the NIC working? It appears to be disabled even though ifconfig says that it is UP. Maybe I need to configure something within the blade server (iDRAC)?

    Read the article

  • System Monitoring Redundancy

    - by Josh Brower
    I consult in a small business environment where I have two HyperV hosts (with <10 VMs) + a couple other servers. I recently had an issue where one of the HyperV hosts had a CPU issue and it came down, bringing most of my non-critical VMs with it, plus a free piece of software that I use for network & system monitoring and availability. Because of this, and the fact that iDRAC locked up to, I did not get any alerts about the crash. So I am wondering how I can (cheaply) get a redundant availability monitoring system in place--Is is as simple as running Nagios or Zenoss (or whatever) on two different HyperV hosts? It just seems like running more than one copy of Nagios/Zenoss/etc could be expensive and have high overhead. Thoughts? Thanks! -Josh

    Read the article

  • VM clients can not access WAN

    - by Saariko
    I have a new VM host on my network, on a Dell R620. The dedicated iDrac is connected with static IP of: 192.168.3.x NIC #1 is connected to my router The eSXI 5.1 host is with IP of 192.168.3.250 The vSphere appliance has a static IP of 192.168.3.241 All the clients on the new host are in the same network 192.168.3.x All clients are Windows 2008 R2 My problem is that non of the clients can access the WAN. I can't ping anything which is beyond my router. I CAN ping anything within my router, even if it's on a different subnet - 192.168.0.x (Router rules are in tact and working) I can ping the gateway (192.168.3.254) One thing that I checked, and is bothering my (but don't know if it has any relevance) is that on the Host Networking properties, there is a vmnic0 (picture) that shows as if it only recognizes 192.168.0.x network - is that so? The command: route print shows me the following details, where I have a duplicate entry for 0.0.0.0 (and one is wrong) - which is probably also why it's not working

    Read the article

  • Cant access Dell BMC IPMI Over IP

    - by Bobb
    I have Dell R210 with iDRAC BMC (new name for old BMC). Which is on-board feature with shared NIC (I believe). Server is on colocation and I didnt set it up before sent there... So I asked for the remote hands to setup IPMI Over IP. They enabled it, set the IP and everything. The IP is different than main box IP. Also the box is cabled to NIC1 and the BMC supposed to share it (am I right?) I can see new IP in the Open Server Administrator (installed on the box). I tried Supermicro IPMI tool and I tried Dell ipmish.exe command like this ipmish -ip xxx -u root -p calvin sysinfo gives BMC is not detected What could be wrong? is there a diagnostics tool I can try? It must be something obvious. I just never used things like that before.... P.S. I read something about encryptions key in the Dell docs. But I understand that is for encrypted IPMI 2.0 and ipmish can use IPMI 1.5 without encryption.

    Read the article

  • "power limit notification" clobbering on 12G Dell servers with RHEL6

    - by Andrew B
    Server: Poweredge r620 OS: RHEL 6.4 Kernel: 2.6.32-358.18.1.el6.x86_64 I'm experiencing application alarms in my production environment. Critical CPU hungry processes are being starved of resources and causing a processing backlog. The problem is happening on all the 12th Generation Dell servers (r620s) in a recently deployed cluster. As near as I can tell, instances of this happening are matching up to peak CPU utilization, accompanied by massive amounts of "power limit notification" spam in dmesg. An excerpt of one of these events: Nov 7 10:15:15 someserver [.crit] CPU12: Core power limit notification (total events = 14) Nov 7 10:15:15 someserver [.crit] CPU0: Core power limit notification (total events = 14) Nov 7 10:15:15 someserver [.crit] CPU6: Core power limit notification (total events = 14) Nov 7 10:15:15 someserver [.crit] CPU14: Core power limit notification (total events = 14) Nov 7 10:15:15 someserver [.crit] CPU18: Core power limit notification (total events = 14) Nov 7 10:15:15 someserver [.crit] CPU2: Core power limit notification (total events = 14) Nov 7 10:15:15 someserver [.crit] CPU4: Core power limit notification (total events = 14) Nov 7 10:15:15 someserver [.crit] CPU16: Core power limit notification (total events = 14) Nov 7 10:15:15 someserver [.crit] CPU0: Package power limit notification (total events = 11) Nov 7 10:15:15 someserver [.crit] CPU6: Package power limit notification (total events = 13) Nov 7 10:15:15 someserver [.crit] CPU14: Package power limit notification (total events = 14) Nov 7 10:15:15 someserver [.crit] CPU18: Package power limit notification (total events = 14) Nov 7 10:15:15 someserver [.crit] CPU20: Core power limit notification (total events = 14) Nov 7 10:15:15 someserver [.crit] CPU8: Core power limit notification (total events = 14) Nov 7 10:15:15 someserver [.crit] CPU2: Package power limit notification (total events = 12) Nov 7 10:15:15 someserver [.crit] CPU10: Core power limit notification (total events = 14) Nov 7 10:15:15 someserver [.crit] CPU22: Core power limit notification (total events = 14) Nov 7 10:15:15 someserver [.crit] CPU4: Package power limit notification (total events = 14) Nov 7 10:15:15 someserver [.crit] CPU16: Package power limit notification (total events = 13) Nov 7 10:15:15 someserver [.crit] CPU20: Package power limit notification (total events = 14) Nov 7 10:15:15 someserver [.crit] CPU8: Package power limit notification (total events = 14) Nov 7 10:15:15 someserver [.crit] CPU10: Package power limit notification (total events = 14) Nov 7 10:15:15 someserver [.crit] CPU22: Package power limit notification (total events = 14) Nov 7 10:15:15 someserver [.crit] CPU15: Core power limit notification (total events = 369) Nov 7 10:15:15 someserver [.crit] CPU3: Core power limit notification (total events = 369) Nov 7 10:15:15 someserver [.crit] CPU1: Core power limit notification (total events = 369) Nov 7 10:15:15 someserver [.crit] CPU5: Core power limit notification (total events = 369) Nov 7 10:15:15 someserver [.crit] CPU17: Core power limit notification (total events = 369) Nov 7 10:15:15 someserver [.crit] CPU13: Core power limit notification (total events = 369) Nov 7 10:15:15 someserver [.crit] CPU15: Package power limit notification (total events = 375) Nov 7 10:15:15 someserver [.crit] CPU3: Package power limit notification (total events = 374) Nov 7 10:15:15 someserver [.crit] CPU1: Package power limit notification (total events = 376) Nov 7 10:15:15 someserver [.crit] CPU5: Package power limit notification (total events = 376) Nov 7 10:15:15 someserver [.crit] CPU7: Core power limit notification (total events = 369) Nov 7 10:15:15 someserver [.crit] CPU19: Core power limit notification (total events = 369) Nov 7 10:15:15 someserver [.crit] CPU17: Package power limit notification (total events = 377) Nov 7 10:15:15 someserver [.crit] CPU9: Core power limit notification (total events = 369) Nov 7 10:15:15 someserver [.crit] CPU21: Core power limit notification (total events = 369) Nov 7 10:15:15 someserver [.crit] CPU23: Core power limit notification (total events = 369) Nov 7 10:15:15 someserver [.crit] CPU11: Core power limit notification (total events = 369) Nov 7 10:15:15 someserver [.crit] CPU13: Package power limit notification (total events = 376) Nov 7 10:15:15 someserver [.crit] CPU7: Package power limit notification (total events = 375) Nov 7 10:15:15 someserver [.crit] CPU19: Package power limit notification (total events = 375) Nov 7 10:15:15 someserver [.crit] CPU9: Package power limit notification (total events = 374) Nov 7 10:15:15 someserver [.crit] CPU21: Package power limit notification (total events = 375) Nov 7 10:15:15 someserver [.crit] CPU23: Package power limit notification (total events = 374) A little Google Fu reveals that this is typically associated with the CPU running hot, or voltage regulation kicking in. I don't think that's what is happening though. Temperature sensors for all servers in the cluster are running fine, Power Cap Policy is disabled in the iDRAC, and my System Profile is set to "Performance" on all of these servers: # omreport chassis biossetup | grep -A10 'System Profile' System Profile Settings ------------------------------------------ System Profile : Performance CPU Power Management : Maximum Performance Memory Frequency : Maximum Performance Turbo Boost : Enabled C1E : Disabled C States : Disabled Monitor/Mwait : Enabled Memory Patrol Scrub : Standard Memory Refresh Rate : 1x Memory Operating Voltage : Auto Collaborative CPU Performance Control : Disabled A Dell mailing list post describes the symptoms almost perfectly. Dell suggested that the author try using the Performance profile, but that didn't help. He ended up applying some settings in Dell's guide for configuring a server for low latency environments and one of those settings (or a combination thereof) seems to have fixed the problem. Kernel.org bug #36182 notes that power-limit interrupt debugging was enabled by default, which is causing performance degradation in scenarios where CPU voltage regulation is kicking in. A RHN KB article (RHN login required) mentions a problem impacting PE r620 and r720 servers not running the Performance profile, and recommends an update to a kernel released two weeks ago. ...Except we are running the Performance profile... Everything I can find online is running me in circles here. What's the heck is going on?

    Read the article

1