Search Results

Search found 2490 results on 100 pages for 'hp uft'.

Page 10/100 | < Previous Page | 6 7 8 9 10 11 12 13 14 15 16 17  | Next Page >

  • HP ENVY 4-Sleekbook or Samsung Series 5 NP530U3B Ultrabook?

    - by Sam
    I am a high school student and I need a laptop within the budget of 650$. I usually have a browser, microsoft office, music, and possibly a movie or something open at once. Will the HP ENVY 4's Intel Core i3 processor be enough to handle this or would I have to get the Samsung series 5 13 inch ultrabook to get this job done? I really like the look of the HP ENVY 4, but I also want a laptop that will be quick enough to handle my needs. PLEASE HELP!

    Read the article

  • HP Procurve Issue Passing Multiple VLANs over a link

    - by MichaelRwat
    Just to start off with I am a Cisco guy that got placed into an HP project. Basic topology overview from outside in: ASA 5505 with two Ethernet connections to a 2910-24 port switch. This switch is then (Cisco Trunking) to a 2626 switch passing vlan (1 untagged and 100 tagged)between them. I created SVI's on each of the switches for both VLAN's for testing purposes. I can not get vlan 100 to pass across this link. I also have trunks configured to AP's off of the switch and can not ping the vlan 100 BVI on the AP's but can reach the vlan 1 BVI. Port 25 on Access layer (2626) connects (trunks) with port A1 of 2610. STP is not running at all on any switch (this is not my network I can't change this nor did I design this) Distribution Sw: MP1-0# show run ip default-gateway 10.100.100.100 vlan 1 name "DATA" untagged 1-22,24-A1,B1 ip address 10.100.100.6 255.255.255.0 no untagged 23 exit vlan 100 name "GUEST" untagged 23 tagged 24-A1 ip address 10.100.102.6 255.255.255.0 exit Access Sw: ip default-gateway 10.100.100.100 vlan 1 name "DEFAULT_VLAN" untagged 1-26 ip address 10.100.100.5 255.255.255.0 exit vlan 100 name "GUEST" ip address 10.100.102.5 255.255.255.0 tagged 15,25 exitt From the ASA I can ping the vlan 100 address of the 2610 but not the 2626 (10.100.102.6)[Not passing the "trunk"] If I plug into an access port vlan 100 of the 2626 I can ping the SVI for vlan 100 as intended. I can not ping across the "trunk" over vlan 100 but I can across vlan 1. There may be something obvious I'm missing but please review my configuration and thank you for the assistance.

    Read the article

  • InterVLAN routing on a HP V1910 series switch

    - by tintix
    Recently bought a HP V1910-16G switch (former 3com 29??) with IPv4 routing capabilities. After unpacking I did a firmware upgrade to the latest 5.20 Release 1513P06. I did set up additional VLANs (#2 and #3) and VLAN interfaces for those. The problem is that connected PCs on different VLAN's can't ping each other. Looks like VLAN routing doesn't even work. So here's my setup: VLAN ID VLAN interface 1 10.0.0.21/24 2 10.0.5.1/24 3 10.0.6.1/24 Have one PC connected to VLAN 2 (IP address 10.0.5.2, default gateway 10.0.5.1) and a second PC connected to VLAN 3 (IP address 10.0.6.2, default gateway 10.0.6.1) Routing table: Destination IP Mask Next Hop 0.0.0.0 0.0.0.0 10.0.0.1 10.0.0.0 255.255.255.0 10.0.0.21 10.0.0.21 255.255.255.255 127.0.0.1 10.0.5.0 255.255.255.0 10.0.5.1 10.0.5.1 255.255.255.255 127.0.0.1 10.0.6.0 255.255.255.0 10.0.6.1 10.0.6.1 255.255.255.255 127.0.0.1 127.0.0.0 255.0.0.0 127.0.0.1 127.0.0.1 255.255.255.255 127.0.0.1 The first PC can't ping the second PC one and vice versa. They only can ping their own gateways and that's all. What I'm doing wrong?

    Read the article

  • HP Procurve 2610 intervlan routing

    - by user19039
    Can anyone tell me why inter vlan routing is working for all vlans except my newly created vlan 4/ I have an hp procurve 2610. Any help would be appreciated. I have basically this 1 switch with all unmanaged switches attached to the core. We have a second 2610 on port 28 Running configuration: ; J9085A Configuration Editor; Created on release #R.11.25 hostname "Core_HP" interface 22 speed-duplex 100-full exit ip routing snmp-server community "public" Unrestricted vlan 1 name "DEFAULT_VLAN" untagged 1-12,17-22,26-27 ip address 192.168.4.6 255.255.255.0 tagged 25 no untagged 13-16,23-24,28 exit vlan 2 name "WAN" untagged 28 ip address 10.254.254.3 255.255.255.0 exit vlan 3 name "Wireless" untagged 13-16,24 ip address 192.168.7.6 255.255.255.0 ip helper-address 192.168.4.2 tagged 27 exit vlan 35 name "guest" untagged 23 tagged 24 exit vlan 4 name "esxi" untagged 25 ip address 10.10.1.1 255.255.248.0 exit ip route 192.168.5.0 255.255.255.0 10.254.254.1 ip route 192.168.6.0 255.255.255.0 10.254.254.1 ip route 0.0.0.0 0.0.0.0 192.168.4.10 show ip route IP Route Entries Destination Gateway VLAN Type Sub-Type M etric Dist. ------------------ --------------- ---- --------- ---------- - --------- ----- 0.0.0.0/0 192.168.4.10 1 static 1 1 10.10.0.0/21 esxi 4 connected 0 0 10.254.254.0/24 WAN 2 connected 0 0 127.0.0.0/8 reject static 0 250 127.0.0.1/32 lo0 connected 0 0 192.168.4.0/24 DEFAULT_VLAN 1 connected 0 0 192.168.5.0/24 10.254.254.1 2 static 1 1 192.168.6.0/24 10.254.254.1 2 static 1 1 192.168.7.0/24 Wireless 3 connected 0 0 show ip Internet (IP) Service IP Routing : Enabled Default TTL : 64 Arp Age : 20 VLAN | IP Config IP Address Subnet Mask Prox y ARP ------------ + ---------- --------------- --------------- ---- ----- DEFAULT_VLAN | Manual 192.168.4.6 255.255.255.0 No WAN | Manual 10.254.254.3 255.255.255.0 No Wireless | Manual 192.168.7.6 255.255.255.0 No esxi | Manual 10.10.1.1 255.255.248.0 No guest | Disabled

    Read the article

  • how to initialize two logical drives on a HP P400i controller without reboot

    - by John
    What I am trying to do is initialize two logical drives on a HP P400i embedded controller without a reboot of the system here my current Array config: array A (SAS, Unused Space: 0 MB) logicaldrive 1 (17.9 GB, RAID 5, OK) logicaldrive 2 (17.9 GB, RAID 5, OK) logicaldrive 3 (75.9 GB, RAID 5, OK) logicaldrive 4 (25.0 GB, RAID 5, OK) physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 72 GB, OK) physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 72 GB, OK) physicaldrive 1I:1:3 (port 1I:box 1:bay 3, SAS, 72 GB, OK) array B (SAS, Unused Space: 0 MB) logicaldrive 5 (99 MB, RAID 0, OK) logicaldrive 6 (68.2 GB, RAID 0, OK) physicaldrive 1I:1:4 (port 1I:box 1:bay 4, SAS, 72 GB, OK) windows 2003 machine running the HpCISs2.sys driver version 6.20.0.32 . I have the ACU and ACU CLI tools installed version 8.28.13.0, P400i firmware version 2.74 . Now what I'd like to do is removes the physical drive 1I:1:4 and delete the two logical drives in array B. then insert a new drive in to bay 4 that contains two new logical drives and have them show up in array B again. So far after I remove the drive and delete the failed logical drives, I insert the new drive and run HPacucli rescan. I get the new drive to show up as unassinged physical drive but I cant figure out now to "for lack of a better word" mount the 2 logical drives on the new unassinged disk. If I reboot the system the array controller picks up the new fourth drive and creates Array B with the drives without problem but I'd really like to not have to reboot the server. Any ideas?

    Read the article

  • How do I resolve certificate errors on HP blade center

    - by Martin Hilton
    I'm trying to sort out the ssl certificate errors that we get when trying to manage our HP c7000 blade enclosures. To that end I have created a signing certificate and imported it into the browser. In Onboard Administrator I created a certificate signing request, which I signed with my CA and then uploaded the certificate. This worked perfectly, and I no longer get any SSL errors when connection to Onboard Administrator. The problem comes when trying to connect through Onboard Administrator to the iLo on the blades themselves. Done by clicking on the "Web Administration" link. Onboard Administrator links to the blade with it's IP address rather than host name. But the certificate signing request that iLo creates uses the host name. Even when this certificate is signed the browser still complains it is for the wrong domain. I either need to be able to get Onboard Administrator to connect to the blades using host name rather than IP address, or get a certificate signing request which contains the IP address as the CN rather than the host name. It doesn't particularly matter which. Does anybody know how to configure this?

    Read the article

  • Ubuntu 12.04 - HP ProLiant DL380 G4 - Load Maxes Out / Unresponsive

    - by Brian S
    Trying to post this question on here. I've posted it on the Ubuntu forums as well with no replies. Recently I upgraded an HP ProLiant DL380 G4 server from Ubuntu 10.04 server to Ubuntu 12.04 server. Upon doing so, the server will not - at random times - get to a load of 400+ and then become completely non-responsive. I use an SNMP graphing program (cacti) and the load steadily increases by about 10 every five minutes until it gets over 400 and the graphing stops. The graphs may not be accurate, but the CPU load averages about 3% before this happens - and right when the load starts increasing, it jumps to about 25% for 15 minutes and dramatically dips down to less than 1% (about 0.3%) until the graphing stops. I'm not able to open a SSH tunnel to the server to do anything. I've checked the /var/log/syslog and all logging stops at that time as well - with nothing else in there. The odd thing is - the server still responds to DNS queries for the zones it is authoritative on during this time - and at normal speed. Just not sure what the next step would be in order to find out what is going on - and how this issue can be corrected. The server cannot stay with Ubuntu 10.04 Server and needs to stay upgraded.

    Read the article

  • Dell 2970 - HP 1/8 G2 autoloader keeps falling off LSI 2032 SCSI chain

    - by middaparka
    I've a somewhat irritating problem with a Dell 2970 that has a HP 1/8 G2 autoloader (the Ultrium LTO 2 model) attached to the Dell/LSI 2032 non-RAID SCSI card. In essence, sometimes the autoloader/drive completely fails to appear on the SCSI chain (i.e.: there's neither a media changer or tape drive present within the device manager) and sometimes it appears but then subsequently disappears at a seemingly random (yet always inconvenient) time, resulting in backup failures. On most occasions, there are simply no errors logged in the system event log, but I did manage to capture a series of LSI_SCSI event ID 11 ("The driver detected a controller error on \Device\RaidPort0") errors followed by an event ID 129, ("Reset to device, \Device\RaidPort0, was issued") error during testing. I've tried two different cables, both with the same effect – sometimes the autoloader appears (for a while), sometimes it's completely absent. There's only one terminator I've tried to use, but as I've since successfully tested the autoloader on multiple occasions (albeit via a Adaptec U160 card on a different machine), my gut feel is that the issue doesn't lie with the terminator, or indeed the autoloader itself. As such, I'm just wondering if anyone has any ideas? It's most likely not relevant, but this is all under Windows SBS 2008, running Backup Exec 12.5 SBS edition (the Dell version), both fully patched. Addidtionally, the autoloader is running the latest firmware. It's been a while since I've dealt with anything SCSI, so all suggestions will be gratefully, gratefully received.

    Read the article

  • HP G61 Laptop wont boot- display stays off, caps and num lock indicators blink repeatedly

    - by Benguy12
    I had my HP G61 laptop running in sleep for a while. When I came back to it about a half-hour later, it was no longer in sleep mode - the power light and the Wi-Fi indicator light were on (I keep Wi-Fi off becuase I use a wired connection) - but nothing was showing on screen. In fact, the display wasn't even turned on. So I let it sit for about 10 minutes but nothing happened. I did a force shut down and rebooted. Instead of a normal boot, the display didnt turn on, the Wi-Fi indicator was off, and the Caps Lock and Num Lock lights just blinked repeatedly. On the external keyboard i use, none of the light indicators were blinking or even on. I tried force shut-down again 10 times, then unplugged all connections except for the power cable (my laptop battery dosent hold a charge for more than 2 minutes, so I always must have a wall connection) and tried to boot again but still nothing happened. I unplugged the battery and even then nothing happened. I also tried booting with the disk drive open, and then with it closed again. On the time it was closed, I was able to successfully boot into Windows, but recieved a "Windows did not shut-down sucessfully" notice. Does anybody know why this may have happened? My PC's specs: Windows 7 Home Premium, 64-bit 4GB of physical RAM, 8GB of vRAM (on a flash drive) AMD Vision x64 processor (don't know any other specs about it) ATI Radeon graphics card, 392 MB DVD-R/W lightscribe drive 2 External hard-disks (first one is 1.5TB, second one is 1TB) custom boot-screen and boot-annimation Standard BIOS apps running before sleep: firefox 10.4 itunes 10.6 adobe photoshop extended CS5.1 rockstar games social club (running in background) microsoft powerpoint 2010 professional edition google chrome I was NOT running Aero or any fancy themes - I was using the normal windows classic theme. I have a desktop icon manager application called Stardock Fences that was also running (it runs as a service/process).

    Read the article

  • GNU screen cannot find terminfo entry on HP-UX

    - by Ency
    I am trying to make screen work on HP-UX B.11.23 U ia64 0308561483 unlimited-user license. Please notice I do not have root access. I have already compiled screen successfully, configured with LIBS=-lcurses. When I try to start screen it wrotes Cannot find terminfo entry for 'xterm'. But there ARE terminfos for the terminal type in screen-4.0.3> ls -a /usr/share/lib/terminfo/x/ . .. x-hpterm x1700 x1720 x1750 xitex xl83 xterm xterms I thing the problem may be there are in non-standard path, because according to man page standard path is /usr/lib/terminfo/?/* What I tried: But as I said I do not have root access so cant make symlink, anyway I tried run screen with filled TERMINFO_DIRS (TERMINFO_DIRS=/usr/share/lib/terminfo/x/ ./screen and TERMINFO_DIRS=/usr/share/lib/terminfo/ ./screen) but none of them work - same error. Change TERM to different values - same error Cannot find terminfo entry for <WHATEVER WHAT WAS IN TERM VAR>. Put something into screenrc and run ./screen -c screenrc screen-4.0.3> cat screenrc attrcolor b ".I" term xterm termcap xterm* LP:hs@ termcapinfo xterm 'Co#256:AB=\E[48;5;%dm:AF=\E[38;5;%dm' defbce "on" But no luck so far, have you got any suggestions? Need some additional information, let me know.

    Read the article

  • HP tx2510us shuts down without warning, now won't boot, no BIOS codes, screen doesn't light

    - by Tim S
    Hey all, HP tx2150us worked great for a year and a half, rarely it would shut down instead of sleeping. It started running hot sometimes, I installed Win7, worked great, still running hot. Before Xmas, it gave me evidence of video errors - jagged lines, rows missing. That same night, it started rebooting, then it shut off and wouldn't boot. It gave me a BIOS code, I shut it off to look up the code online. When I turned it on again, it won't boot at all. The LEDs all light up, the fan, HD, and optical all spin up, but the screen never lights up and it doesn't try to boot, nor does it blink any BIOS codes. It just acts like it's sleeping, and won't wake up. I suspected heat problems, so I disassembled it, cleaned the crap out of the fan, and reassembled it, breaking the stereo mic connector. Oh well. When I reassembled it, it booted up into Win7 again, but kept shutting down for no discernible reason. After a dozen or so random reboots like that, it is now back to where it was - turns on but doesn't boot or give BIOS codes. The screen never lights, and everything spins up then idles. Any ideas? I really can't afford to buy a new one and I use(d) it to take ALL my notes, that's why I got a tablet in the first place.

    Read the article

  • HP EliteBook 8440P - USB ports stop working on docking station

    - by r0ca
    I have a HP Elitebook 8440P running Windows XP Pro SP3. I installed it on my docking station and everything went smooth for a while. Last week, my mouse and any other USB devices stoped working sudenly... It was working fine on my laptop itself but nothing on my docking station. LCD attached monitor works and same for LAN and PS2 keyboard. I updated the BIOS, Chipset, Video Drivers, also changed my docking station by a brand new one but the problem still comes back. I also noticed something in Device Manager... A Generic USB Root Hub has an error on it, a Yellow/Orange exclamation mark. I tried to update that driver but no luck. Windows is unable to process it. This seems to be the problem but can't fix it. I may only re-image my laptop but for me, I need to avoid that since I have so many apps installed on it. If anybody has any advice, I'll take it!

    Read the article

  • Issues connecting to HP ProCurve switches

    - by BriGuy
    We are having a very strange issue trying to connect to our infrastructure switches via SSH. When you first try connecting to them, the switches will prompt for the password - and then just sit there after it is entered. If you create a second SSH session to the switch (while letting the first one remain open and just sitting there) it will let you log right in. The switches are doing the same thing with RADIUS and local authentication. The other strange part to all of this, is that about 10 switches started doing it all at the same time. As far as actual configuration of the switches, nothing has changed. Occasionally, one switch will start working like normal, but then stop again. These are all HP ProCurve managed switches, but all different models/firmware. Some switches that are not working are using the same firmware as others that are working. UPDATE: 20130312 I am also seeing this same behavior when trying to use telnet. The first telnet session just hangs there, and the second telnet session will let me log in. Rebooting the switches seems to get them working, but I still have 5 production switches that cannot easily be rebooted because of their production roles. Is anyone aware of anything else that can be switched on/off that may reset the logon for remote management or something like that?

    Read the article

  • Hp Pavilion dv6000 wont boot right and freezes

    - by MalwareManiac
    I have an hp pavilion dv6000 that was having windows issues recently including randomly freezing. I eventually concluded that the hard drive was bad (And I was correct as the bad drive started making funny noises and quit working soon after). So I replaced it with a known good drive and put windows on it and it worked for a few hours. After a few restarts startup didn't even make it to the login screen. It just stays at a lighted black screen until I restarted. After another restart it made it to windows but then froze after a few minutes. A few more restarts yielded one of these two results. Like I mentioned earlier I have a know good drive in it and I also replaced the memory that was in it with a know good stick along with running memtest with no errors. So What does that leave? a corrupted windows installation? Motherboard? CPU? Any ideas?

    Read the article

  • How to use sudo with rcp command to copy files from linux host to HP-UX host?

    - by Justin
    I'm having this issue where when I try to use sudo to rcp some files from a Linux host to an HP-UX host (note that the destination directory requires root access to write to), I get the following error from HP-UX's side: remshd: Login incorrect. I should note that the passwords for the Linux host and the HP-UX host are different. The command doesn't seem to give me a chance to enter the proper HP-UX password and automatically defaults to this error.

    Read the article

  • Printing fails after first print with Centos 6 and HP LaserJet P3015dn printer

    - by Gavin Simpson
    Centos 6 recognises and configures a HP LaserJet P3015dn printer connected via USB. This machine is being configured as a small group file/print server. I can print a test page, which is processed/printed correctly. The next time printing is attempted (say printing a second test page), the page is not printed and the printer is set to disabled. The status of the printer is stated as: Stopped - /usr/lib/cups/backend/hp failed in the printer configuration dialogue. /var/log/cups/error_log contains this information (first two lines were there prior to the failed print job) E [24/Jun/2004:09:12:57 +0100] Returning HTTP Forbidden for Resume-Printer (ipp://localhost/printers/HP-LaserJet-P3010-Series) from localhost E [24/Jun/2004:09:20:59 +0100] Returning HTTP Forbidden for CUPS-Delete-Printer (ipp://localhost/printers/HP-LaserJet-P3010-Series) from localhost D [24/Jun/2004:09:37:28 +0100] [Job 28] The following messages were recorded from 09:36:43 AM to 09:37:28 AM D [24/Jun/2004:09:37:28 +0100] [Job 28] Adding start banner page "none". D [24/Jun/2004:09:37:28 +0100] [Job 28] Adding end banner page "none". D [24/Jun/2004:09:37:28 +0100] [Job 28] File of type application/vnd.cups-banner queued by "gavin". D [24/Jun/2004:09:37:28 +0100] [Job 28] hold_until=0 D [24/Jun/2004:09:37:28 +0100] [Job 28] Queued on "HP-LaserJet-P3010-Series" by "gavin". D [24/Jun/2004:09:37:28 +0100] [Job 28] job-sheets=none,none D [24/Jun/2004:09:37:28 +0100] [Job 28] argv[0]="HP-LaserJet-P3010-Series" D [24/Jun/2004:09:37:28 +0100] [Job 28] argv[1]="28" D [24/Jun/2004:09:37:28 +0100] [Job 28] argv[2]="gavin" D [24/Jun/2004:09:37:28 +0100] [Job 28] argv[3]="Test Page" D [24/Jun/2004:09:37:28 +0100] [Job 28] argv[4]="1" D [24/Jun/2004:09:37:28 +0100] [Job 28] argv[5]="job-uuid=urn:uuid:b3370a97-4ab6-3451-40a2-6239b13fa3e1 job-originating-host-name=localhost" D [24/Jun/2004:09:37:28 +0100] [Job 28] argv[6]="/var/spool/cups/d00028-001" D [24/Jun/2004:09:37:28 +0100] [Job 28] envp[0]="CUPS_CACHEDIR=/var/cache/cups" D [24/Jun/2004:09:37:28 +0100] [Job 28] envp[1]="CUPS_DATADIR=/usr/share/cups" D [24/Jun/2004:09:37:28 +0100] [Job 28] envp[2]="CUPS_DOCROOT=/usr/share/cups/www" D [24/Jun/2004:09:37:28 +0100] [Job 28] envp[3]="CUPS_FONTPATH=/usr/share/cups/fonts" D [24/Jun/2004:09:37:28 +0100] [Job 28] envp[4]="CUPS_REQUESTROOT=/var/spool/cups" D [24/Jun/2004:09:37:28 +0100] [Job 28] envp[5]="CUPS_SERVERBIN=/usr/lib/cups" D [24/Jun/2004:09:37:28 +0100] [Job 28] envp[6]="CUPS_SERVERROOT=/etc/cups" D [24/Jun/2004:09:37:28 +0100] [Job 28] envp[7]="CUPS_STATEDIR=/var/run/cups" D [24/Jun/2004:09:37:28 +0100] [Job 28] envp[8]="HOME=/var/spool/cups/tmp" D [24/Jun/2004:09:37:28 +0100] [Job 28] envp[9]="PATH=/usr/lib/cups/filter:/usr/bin:/usr/sbin:/bin:/usr/bin" D [24/Jun/2004:09:37:28 +0100] [Job 28] envp[10]="[email protected]" D [24/Jun/2004:09:37:28 +0100] [Job 28] envp[11]="SOFTWARE=CUPS/1.4.2" D [24/Jun/2004:09:37:28 +0100] [Job 28] envp[12]="TMPDIR=/var/spool/cups/tmp" D [24/Jun/2004:09:37:28 +0100] [Job 28] envp[13]="USER=root" D [24/Jun/2004:09:37:28 +0100] [Job 28] envp[14]="CUPS_SERVER=/var/run/cups/cups.sock" D [24/Jun/2004:09:37:28 +0100] [Job 28] envp[15]="CUPS_ENCRYPTION=IfRequested" D [24/Jun/2004:09:37:28 +0100] [Job 28] envp[16]="IPP_PORT=631" D [24/Jun/2004:09:37:28 +0100] [Job 28] envp[17]="CHARSET=utf-8" D [24/Jun/2004:09:37:28 +0100] [Job 28] envp[18]="LANG=en_US.UTF-8" D [24/Jun/2004:09:37:28 +0100] [Job 28] envp[19]="PPD=/etc/cups/ppd/HP-LaserJet-P3010-Series.ppd" D [24/Jun/2004:09:37:28 +0100] [Job 28] envp[20]="RIP_MAX_CACHE=8m" D [24/Jun/2004:09:37:28 +0100] [Job 28] envp[21]="CONTENT_TYPE=application/vnd.cups-banner" D [24/Jun/2004:09:37:28 +0100] [Job 28] envp[22]="DEVICE_URI=hp:/usb/HP_LaserJet_P3010_Series?serial=VNBV993GM4" D [24/Jun/2004:09:37:28 +0100] [Job 28] envp[23]="PRINTER_INFO=Hewlett-Packard HP LaserJet P3010 Series" D [24/Jun/2004:09:37:28 +0100] [Job 28] envp[24]="PRINTER_LOCATION=electra.geog.ucl.ac.uk" D [24/Jun/2004:09:37:28 +0100] [Job 28] envp[25]="PRINTER=HP-LaserJet-P3010-Series" D [24/Jun/2004:09:37:28 +0100] [Job 28] envp[26]="CUPS_FILETYPE=document" D [24/Jun/2004:09:37:28 +0100] [Job 28] envp[27]="FINAL_CONTENT_TYPE=application/vnd.cups-postscript" D [24/Jun/2004:09:37:28 +0100] [Job 28] Started filter /usr/lib/cups/filter/bannertops (PID 2858) D [24/Jun/2004:09:37:28 +0100] [Job 28] Started filter /usr/lib/cups/filter/pstops (PID 2859) D [24/Jun/2004:09:37:28 +0100] [Job 28] Started backend /usr/lib/cups/backend/hp (PID 2860) D [24/Jun/2004:09:37:28 +0100] [Job 28] load_banner(filename="/var/spool/cups/d00028-001") D [24/Jun/2004:09:37:28 +0100] [Job 28] Page = 612x792; 12,12 to 600,780 D [24/Jun/2004:09:37:28 +0100] [Job 28] Page = 612x792; 12,12 to 600,780 D [24/Jun/2004:09:37:28 +0100] [Job 28] slow_collate=0, slow_duplex=0, slow_order=0 D [24/Jun/2004:09:37:28 +0100] [Job 28] Before copy_comments - %!PS-Adobe-3.0 D [24/Jun/2004:09:37:28 +0100] [Job 28] %!PS-Adobe-3.0 D [24/Jun/2004:09:37:28 +0100] [Job 28] %%BoundingBox: 12 12 600 780 D [24/Jun/2004:09:37:28 +0100] [Job 28] %cupsRotation: 0 D [24/Jun/2004:09:37:28 +0100] [Job 28] %%Creator: bannertops/CUPS v1.4.2 D [24/Jun/2004:09:37:28 +0100] [Job 28] %%CreationDate: Thu 24 Jun 2004 09:36:43 AM BST D [24/Jun/2004:09:37:28 +0100] [Job 28] %%LanguageLevel: 2 D [24/Jun/2004:09:37:28 +0100] [Job 28] %%DocumentData: Clean7Bit D [24/Jun/2004:09:37:28 +0100] [Job 28] %%Title: (Test Page) D [24/Jun/2004:09:37:28 +0100] [Job 28] %%For: (gavin) D [24/Jun/2004:09:37:28 +0100] [Job 28] %%Pages: 1 D [24/Jun/2004:09:37:28 +0100] [Job 28] %%DocumentSuppliedResources: font Monospace D [24/Jun/2004:09:37:28 +0100] [Job 28] %%+ font Monospace-Bold D [24/Jun/2004:09:37:28 +0100] [Job 28] %%+ font Monospace-BoldOblique D [24/Jun/2004:09:37:28 +0100] [Job 28] %%+ font Monospace-Oblique D [24/Jun/2004:09:37:28 +0100] [Job 28] %%EndComments D [24/Jun/2004:09:37:28 +0100] [Job 28] Before copy_prolog - %%BeginProlog D [24/Jun/2004:09:37:28 +0100] [Job 28] STATE: +connecting-to-device D [24/Jun/2004:09:37:28 +0100] [Job 28] prnt/backend/hp.c 762: ERROR: cannot open channel PRINT D [24/Jun/2004:09:37:28 +0100] [Job 28] Backend returned status 1 (failed) D [24/Jun/2004:09:37:28 +0100] [Job 28] Printer stopped due to backend errors; please consult the error_log file for details. D [24/Jun/2004:09:37:28 +0100] [Job 28] End of messages D [24/Jun/2004:09:37:28 +0100] [Job 28] printer-state=5(stopped) D [24/Jun/2004:09:37:28 +0100] [Job 28] printer-state-message="/usr/lib/cups/backend/hp failed" D [24/Jun/2004:09:37:28 +0100] [Job 28] printer-state-reasons=paused /var/log/messages contains the following reports associated with the recognition of the printer and the failed print job: Jun 24 09:35:07 electra kernel: usb 1-8: new high speed USB device using ehci_hcd and address 2 Jun 24 09:35:07 electra kernel: usb 1-8: New USB device found, idVendor=03f0, idProduct=8d17 Jun 24 09:35:07 electra kernel: usb 1-8: New USB device strings: Mfr=1, Product=2, SerialNumber=3 Jun 24 09:35:07 electra kernel: usb 1-8: Product: HP LaserJet P3010 Series Jun 24 09:35:07 electra kernel: usb 1-8: Manufacturer: Hewlett-Packard Jun 24 09:35:07 electra kernel: usb 1-8: SerialNumber: VNBV993GM4 Jun 24 09:35:07 electra kernel: usb 1-8: configuration #1 chosen from 1 choice Jun 24 09:35:07 electra kernel: usblp0: USB Bidirectional printer dev 2 if 0 alt 1 proto 2 vid 0x03F0 pid 0x8D17 Jun 24 09:35:07 electra kernel: usbcore: registered new interface driver usblp Jun 24 09:35:07 electra udev-configure-printer: invalid or missing IEEE 1284 Device ID Jun 24 09:35:08 electra hp[1942]: io/hpmud/pp.c 627: unable to read device-id ret=-1 Jun 24 09:35:09 electra python: io/hpmud/pp.c 627: unable to read device-id ret=-1 Jun 24 09:35:51 electra kernel: usblp0: removed Jun 24 09:37:28 electra hp[2860]: io/hpmud/dot4.c 254: unable to read Dot4ReverseReply data: Resource temporarily unavailable exp=2 act=0 Jun 24 09:37:28 electra hp[2860]: io/hpmud/dot4.c 330: invalid DOT4InitReply: cmd=0, result=20#012, revision=0 Jun 24 09:37:28 electra hp[2860]: prnt/backend/hp.c 762: ERROR: cannot open channel PRINT I am now at a loss as to how to proceed to get this printer working on my Centos machine. How can I configure the machine to print more than a single print job without needing to be unplugged/plugged in repeatedly?

    Read the article

  • HP Pavilion tx2000 - Wifi adapter no longer works after moving from 12.04 to a 12.10 clean install

    - by Marek L.
    I have a HP Pavilion tx2000 that I have been running Ubuntu 12.04 on for a couple of months without any problems (wifi worked great) until yesterday when my hard drive failed. I replaced the hard drive and decided to install Ubuntu 12.10. Unlike 12.04, the wifi did not work after the installation finished and all the updates where installed (over Ethernet). The network drop down in the top right didn't even show a wireless option. I Googled about for a bit and found some solutions that seemed like they might work. Unfortunately they did not. Here is what I tried: sudo apt-get remove bcmwl-kernel-source sudo apt-get install b43-fwcutter sudo apt-get install firmware-b43-lpphy-installer Restart the computer. And the wifi still didn't work. At which point I panicked a bit and tried to undo the previous commands by running: sudo apt-get remove b43-fwcutter firmware-b43-lpphy-installer sudo apt-get install bcmwl-kernel-source Restart the computer. The wifi still doesn't work. This is where I stopped because I have no idea what I am doing and don't want to mess something up. The network drop down still doesn't show a wireless option and the hardware wifi switch on the laptop is amber (it turns blue when the wifi is on). Using the hardware switch does not change the color. Output from: sudo lspci ... 08:00.0 Network controller: Broadcom Corporation BCM4322 802.11a/b/g/n Wireless LAN Controller (rev 01) ... Output from: sudo lshw -class network *-network UNCLAIMED description: Network controller product: BCM4322 802.11a/b/g/n Wireless LAN Controller vendor: Broadcom Corporation physical id: 0 bus info: pci@0000:08:00.0 version: 01 width: 64 bits clock: 33MHz capabilities: pm msi pciexpress bus_master cap_list configuration: latency=0 resources: memory:d1100000-d1103fff ... Output from: sudo rfkill list all 0: hp-wifi: Wireless LAN Soft blocked: no Hard blocked: yes UPDATE: After writing up this question tried the following command: sudo rfkill unblock all At first it didn't do anything but after running it about four times, sudo rfkill list all now returns: 0: hp-wifi: Wireless LAN Soft blocked: no Hard blocked: no But the network menu still does not have a wireless option and the hardware switch still glows amber. Pushing the hardware switch turns the hard block back on and I have to run sudo rfkill unblock all multiple times again to turn it off. Any help is appreciated! Update 2: Full output from sudo lspci -nn: 00:00.0 Host bridge [0600]: Advanced Micro Devices [AMD] RS780 Host Bridge [1022:9600] 00:01.0 PCI bridge [0604]: Advanced Micro Devices [AMD] RS780/RS880 PCI to PCI bridge (int gfx) [1022:9602] 00:04.0 PCI bridge [0604]: Advanced Micro Devices [AMD] RS780/RS880 PCI to PCI bridge (PCIE port 0) [1022:9604] 00:05.0 PCI bridge [0604]: Advanced Micro Devices [AMD] RS780/RS880 PCI to PCI bridge (PCIE port 1) [1022:9605] 00:06.0 PCI bridge [0604]: Advanced Micro Devices [AMD] RS780 PCI to PCI bridge (PCIE port 2) [1022:9606] 00:11.0 SATA controller [0106]: Advanced Micro Devices [AMD] nee ATI SB7x0/SB8x0/SB9x0 SATA Controller [AHCI mode] [1002:4391] 00:12.0 USB controller [0c03]: Advanced Micro Devices [AMD] nee ATI SB7x0/SB8x0/SB9x0 USB OHCI0 Controller [1002:4397] 00:12.1 USB controller [0c03]: Advanced Micro Devices [AMD] nee ATI SB7x0 USB OHCI1 Controller [1002:4398] 00:12.2 USB controller [0c03]: Advanced Micro Devices [AMD] nee ATI SB7x0/SB8x0/SB9x0 USB EHCI Controller [1002:4396] 00:13.0 USB controller [0c03]: Advanced Micro Devices [AMD] nee ATI SB7x0/SB8x0/SB9x0 USB OHCI0 Controller [1002:4397] 00:13.1 USB controller [0c03]: Advanced Micro Devices [AMD] nee ATI SB7x0 USB OHCI1 Controller [1002:4398] 00:13.2 USB controller [0c03]: Advanced Micro Devices [AMD] nee ATI SB7x0/SB8x0/SB9x0 USB EHCI Controller [1002:4396] 00:14.0 SMBus [0c05]: Advanced Micro Devices [AMD] nee ATI SBx00 SMBus Controller [1002:4385] (rev 3a) 00:14.1 IDE interface [0101]: Advanced Micro Devices [AMD] nee ATI SB7x0/SB8x0/SB9x0 IDE Controller [1002:439c] 00:14.2 Audio device [0403]: Advanced Micro Devices [AMD] nee ATI SBx00 Azalia (Intel HDA) [1002:4383] 00:14.3 ISA bridge [0601]: Advanced Micro Devices [AMD] nee ATI SB7x0/SB8x0/SB9x0 LPC host controller [1002:439d] 00:14.4 PCI bridge [0604]: Advanced Micro Devices [AMD] nee ATI SBx00 PCI to PCI Bridge [1002:4384] 00:14.5 USB controller [0c03]: Advanced Micro Devices [AMD] nee ATI SB7x0/SB8x0/SB9x0 USB OHCI2 Controller [1002:4399] 00:18.0 Host bridge [0600]: Advanced Micro Devices [AMD] Family 11h Processor HyperTransport Configuration [1022:1300] (rev 40) 00:18.1 Host bridge [0600]: Advanced Micro Devices [AMD] Family 11h Processor Address Map [1022:1301] 00:18.2 Host bridge [0600]: Advanced Micro Devices [AMD] Family 11h Processor DRAM Controller [1022:1302] 00:18.3 Host bridge [0600]: Advanced Micro Devices [AMD] Family 11h Processor Miscellaneous Control [1022:1303] 00:18.4 Host bridge [0600]: Advanced Micro Devices [AMD] Family 11h Processor Link Control [1022:1304] 01:05.0 VGA compatible controller [0300]: Advanced Micro Devices [AMD] nee ATI RS780M/RS780MN [Mobility Radeon HD 3200 Graphics] [1002:9612] 08:00.0 Network controller [0280]: Broadcom Corporation BCM4322 802.11a/b/g/n Wireless LAN Controller [14e4:432b] (rev 01) 09:00.0 Ethernet controller [0200]: Realtek Semiconductor Co., Ltd. RTL8111/8168B PCI Express Gigabit Ethernet controller [10ec:8168] (rev 02)

    Read the article

  • Unable to retrieve information form HP-UX pst_status object

    - by bogertron
    I am attempting to get process information by using the HP-UX C/C++ library. After scouring the internet, I have discovered that HP-UX has the pstat.h header file which allows programmers to retrieve the process information. After attempting to understand code from the internet hp website, I attempted to create a little test sample to comprehend what the code does. I attempted to use example 3, however, I ran into several issues. The first issue came when I attempted to execute the following line of code: (void)printf("pid is %d, command is %s\n", pst[i].pst_pid, pst[i].pst_ucomm); When I attempted to print the string, I hit a memory fault. So I decided to attempt to see what the string is and came up with the following: #include <sys/param.h> #include <sys/pstat.h> #include <sys/unistd.h> #include <string.h> int main(int argc, char** argv) { #define BURST ((size_t)10) struct pst_status pst[BURST]; int i, count; int idx = 0; /* index within the context */ int index = 0; /* loop until count == 0, will occur all have been returned */ while ((count=pstat_getproc(pst, sizeof(pst[0]),BURST,idx))>0) { index = 0; printf("index: %d", index); /* got count (max of BURST) this time. process them */ while (pst[i].pst_ucomm[index] != '\0') { printf("%c", pst[i].pst_ucomm[index]); index++; } printf("\n"); for (i = 0; i < count; i++) { printf("pid is %d, command is \n", pst[i].pst_pid); } /* * now go back and do it again, using the next index after * the current 'burst' */ idx = pst[count-1].pst_idx + 1; } if (count == -1) perror("pstat_getproc()"); #undef BURST } Unfortunately, what happens is that I get the first process printed, then pid is 2, command is pid is 2, command is pid is 2, command is... I know that I must be doing something foolish since my C/C++ skills are not that great, but I cannot figure out what the issue is since the code is largely copied from the hp website. So here's the question(s) for clarity: 1. Why can't printf("%s", pst[i].pst_ucomm); handle strings? 2. Why can't I iterate over the processes in the system? Any help is greatly appreciated.

    Read the article

  • Access Officejet Pro L7590 memory card reader

    - by luri
    I can't manage to access my printer's memory card reader in Nautilus. I can just access it with hp-unload. Here's a sample output from this command: lubuntu@L-X6:~$ hp-unload hp:/net/Officejet_Pro_L7500?zc=HP065193 HP Linux Imaging and Printing System (ver. 3.10.6) Photo Card Access Utility ver. 3.3 Copyright (c) 2001-9 Hewlett-Packard Development Company, LP This software comes with ABSOLUTELY NO WARRANTY. This is free software, and you are welcome to distribute it under certain conditions. See COPYING file for more details. Using device: hp:/net/Officejet_Pro_L7500?zc=HP065193 |error: Photo card write failed (Card may be write protected) / Photocard on device hp:/net/Officejet_Pro_L7500?zc=HP065193 mounted DO NOT REMOVE PHOTO CARD UNTIL YOU EXIT THIS PROGRAM warning: Photo card is write protected. Type 'help' for a list of commands. Type 'exit' to quit. pcard: / > ls \ Name Size Type dcim/ directory eos_digi.tal 0 B unknown/unknown 1 files, 0 B pcard: / > cd dcim |pcard: /dcim > ls | Name Size Type . directory .. directory 100eos5d/ directory 267canon/ directory 270canon/ directory 271canon/ directory 272canon/ directory 0 files, 0 B pcard: /dcim > cd 272canon -pcard: /dcim/272canon > ls \ Name Size Type . directory .. directory _mg_7201.jpg 3.1 MB image/jpeg ...........(some more files)................. _mg_7281.jpg 2.5 MB image/jpeg _mg_7282.jpg 2.5 MB image/jpeg 82 files, 241.6 MB (253377883) How can I acess it from nautilus or mount it as a filesystem? Note that this is similar to this other question: Can't get HP Officejet 6500 card reader to work. but actually there seemed to be no supported device here, while in my case I manage to access the memory card from hp-unload.

    Read the article

  • HP ACU shows parity initialization failed (with screenshot)

    - by lbanz
    I put in a new drive due to a hard drive failure. When the rebuild got to 100%, the controller fails and I need to reboot the server to bring it online. I had to do this about three times and it eventually finished rebuilding. But I found that it says parity initialization status failed. I've left it for a few hours but it didn't seem to reinitialize. Then I ran the insight online diagnostic tools and it reported the disk that I put in reached read/write error threshold. So I'm beginning to think that the brand new disk I put in is faulty. Before I put in the disk, the parity initialization was at a finished state. Should I replace the new disk I put in? I'm very worried as I think the parity is broken. Or is there a way to kick start the initialization process?

    Read the article

  • HP 6350b Laptop is my battery really dead or is it a software problem

    - by Datapimp23
    I installed windows 7 and noticed that the battery status was "plugged in, not charging". I tried unplugging the battery, uninstalling the microsoft ACPI compliant Control Method, updating bios,windows. All to no avail. at first I tought it was related to windows 7 because it's a brand new laptop. But I also tested with a knoppix live cd, and there the output of acpi -V is this Battery 0: Unknown, 0% What else can I test to figure out what's going on.

    Read the article

  • Laptop choice for development: MacBook Pro 17 vs Dell Studio XPS 16 vs HP Envy 15

    - by Shalan
    Hey! First things first - let me state that I am not intending to play games on this - I have narrowed down to these 3 purely based on specs and its individual brand reliability in the market. I intend to primarily use: Visual Studio 2008 Pro a lot (develop and deploy on Windows platforms) SQL Server 2005 Oracle 10g Adobe Photoshop CS4 Microsoft Expression Studio Google Sketchup I currently use a desktop PC (Core2Duo 2.66Ghz with 3GB DDRII memory) running Vista Business 32-bit - and I have to admit that, especially for Visual Studio, its quite sluggish to a point where it affects productivity. Furthermore, I intend to only use the notebook on a table - with a cooled surface, like granite :) - so I would appreciate people's input with regard to heat issues. Im aware that the Dell's primary exhaust gets blocked by the lid when open, but some reviews don't seem to place extraordinary emphasis on heat issues resulting from this. My options for the Dell/Alienware: Core i7 720QM 4GB DDRIII memory ATI mobility 3670 (512) 128GB Solid State Drive 16-inch Full HD RGB-LED LCD display (1080p) 3-year next-business-day support My configuration for the Apple MBP: Core2Duo 2.8Ghz (Im assuming the T9600) 4GB DDRIII memory 128GB Solid State Drive standard 1 year support The one advantage I think of with the MBP is that I can have the addition of OSX (though Im unsure what I would use it for, but purely to play around with a much-boasted-about OS) What are your thoughts on this, especially regarding build-quality, heat, performance and battery-life? Much thanks! ~shalan

    Read the article

  • HP Pavilion dv6000 graphics issue

    - by Tony
    A few days ago my laptop seized up on me while I was playing a game. When I restarted the computer, it sent me back to 640x480 resolution with 16 colors (clearly a graphical issue). In device manager, it shows an error, stating "Windows has stopped this device because it has reported problems. (Code 43)" regarding the video card. Upon removing and re-installing the drivers using both Windows Update and my own searching through nvidia's site, it's given me zero results. For kicks, I ran my antivirus (you never know!) and registry cleaner to see if anything would turn up. The antivirus found nothing, but CCleaner found 27 registry errors all dealing with my video card. What could be the cause of this, and what course of action would you recommend in this situation? Thanks in advance for the help! OS: Windows 7 Professional GPU: nvidia GeForce 8400M GS

    Read the article

  • HP ProCurve Port Mode Configuration Question

    - by SvrGuy
    We have a ProCurve Switch 2810-48G (J9022A). We need to disable auto negotiation on two ports and manually configure them to be full duplex gige ports. From the web GUI, Configuration Tab, Port Configuration sub tab, I am only presented with the option to configure the port as Auto - 1000. I take this to mean, auto negotiate duplex, manually configure the speed to be gige. How do I manually configure the port such that it is manually configured to use full duplex, 1000 mbs?

    Read the article

  • HP DL380 RAID5 Mistake

    - by Eddy
    I had drives fail in both logical drives on a server. When I replaced failed 146GB drive in Raid 5 array with four (4) 146GB drives. On reboot the Smart Array controller asked if I wanted to accept data loss. Guess mistake to choose yes. Can't seem to find a way to get system to repair RAID5 but it seems to want to just create a new partition. Is there anyway I can go back and get the system to restore the data from other three drives now that I said accept data loss?

    Read the article