Search Results

Search found 14861 results on 595 pages for 'high speed computing'.

Page 108/595 | < Previous Page | 104 105 106 107 108 109 110 111 112 113 114 115  | Next Page >

  • How can I optimize MVC and IIS pipeline to obtain higher speed?

    - by Andy
    Hi, I am doing performance tweaking of a simple app that uses MVC on IIS 7.5. I have a StopWatch starting up in Application_BeginRequest and I take a snapshot at Controller.OnActionExecuting. So I measure the time spend in the entire IIS pipeline: from request receipt to the moment execution finally gets to my controller. I obtain 700 microseconds on my 3GHz quad-core (project compiled Release x64), and I wonder where the bottleneck is, especially hearing some people say that one can get up to 8000 page loads per second with MVC. How can I optimize MVC and IIS pipeline to obtain higher speed?

    Read the article

  • fHow can I get Opera speed-dial and password management features in other browsers?

    - by Howard Guo
    I heavily rely on Opera's speed dial and password management features. Lack of these two features is really stopping me from switching to another web browser such as Chrome or Firefox. Opera's password management has two unique characteristics which I rely on heavily: It saves passwords on all pages, (apparently) despite the page's meta data asking not to save passwords. It offers keyboard shortcut and button to automatically fill in username/passwords and all other fields in a login form, then automatically submit the form. How can I get those functions in other browsers? Thank you!

    Read the article

  • Need to speed up the results of this SQL statement. Any advice?

    - by jeffself
    I've got the following SQL Statement that needs some major speed up. The problem is I need to search on two fields, where each of them is calling several sub-selects. Is there a way to join the two fields together so I call the sub-selects only once? SELECT billyr, billno, propacct, vinid, taxpaid, duedate, datepif, propdesc FROM trcdba.billspaid WHERE date(datepif) > '01/06/2009' AND date(datepif) <= '01/06/2010' AND custno in (select custno from cwdba.txpytaxid where taxpayerno in (select taxpayerno from cwdba.txpyaccts where accountno in (select accountno from rtadba.reasacct where controlno = 1234567))) OR custno2 in (select custno from cwdba.txpytaxid where taxpayerno in (select taxpayerno from cwdba.txpyaccts where accountno in (select accountno from rtadba.reasacct where controlno = 1234567)))

    Read the article

  • How to increase query speed without using full-text search?

    - by andre matos
    This is my simple query; By searching selectnothing I'm sure I'll have no hits. SELECT nome_t FROM myTable WHERE nome_t ILIKE '%selectnothing%'; This is the EXPLAIN ANALYZE VERBOSE Seq Scan on myTable (cost=0.00..15259.04 rows=37 width=29) (actual time=2153.061..2153.061 rows=0 loops=1) Output: nome_t Filter: (nome_t ~~* '%selectnothing%'::text) Total runtime: 2153.116 ms myTable has around 350k rows and the table definition is something like: CREATE TABLE myTable ( nome_t text NOT NULL, ) I have an index on nome_t as stated below: CREATE INDEX idx_m_nome_t ON myTable USING btree (nome_t); Although this is clearly a good candidate for Fulltext search I would like to rule that option out for now. This query is meant to be run from a web application and currently it's taking around 2 seconds which is obviously too much; Is there anything I can do, like using other index methods, to improve the speed of this query?

    Read the article

  • generic binary Search in c#

    - by Pro_Zeck
    Below is my Generic Binary Search it works ok with the intgers type array it finds all the elements in it . But the Problem Arises when i use a string array to find any string data. It runs ok for the first index and last index elements but i cant find the middle elements. Stringarray = new string[] { "b", "a", "ab", "abc", "c" }; public static void BinarySearch<T>(T[] array, T searchFor, Comparer<T> comparer) { int high, low, mid; high = array.Length - 1; low = 0; if (array[0].Equals(searchFor)) Console.WriteLine("Value {0} Found At Index {1}",array[0],0); else if (array[high].Equals(searchFor)) Console.WriteLine("Value {0} Found At Index {1}", array[high], high); else { while (low <= high) { mid = (high + low) / 2; if (comparer.Compare(array[mid], searchFor) == 0) { Console.WriteLine("Value {0} Found At Index {1}", array[mid], mid); break; } else { if (comparer.Compare(searchFor, array[mid]) > 0) high = mid + 1; else low = mid + 1; } } if (low > high) { Console.WriteLine("Value Not Found In the Collection"); } } }

    Read the article

  • How to speed up saving data to database over the internet?

    - by robert_d
    I am using C#, Entity Framework and SQL Server 2008 Express. I am connected to the database over the internet. What is the best method to speed up saving/updating data to database? It takes 87 seconds to save 180 records to the database. It takes only 3.5 seconds to save the same number of records to local (on the same machine) SQL Server. For every record that I save/update I check if record with this primary key exists in the database, if it doesn't exists I simply save it, if it exists I update it using ObjectContext.ApplyCurrentValues(entitySetName, currentEntity) method.

    Read the article

  • How to speed up dumping a DataTable into an Excel worksheet?

    - by AngryHacker
    I have the following routine that dumps a DataTable into an Excel worksheet. private void RenderDataTableOnXlSheet(DataTable dt, Excel.Worksheet xlWk, string [] columnNames, string [] fieldNames) { // render the column names (e.g. headers) for (int i = 0; i < columnNames.Length; i++) xlWk.Cells[1, i + 1] = columnNames[i]; // render the data for (int i = 0; i < fieldNames.Length; i++) { for (int j = 0; j < dt.Rows.Count; j++) { xlWk.Cells[j + 2, i + 1] = dt.Rows[j][fieldNames[i]].ToString(); } } } For whatever reason, dumping DataTable of 25 columns and 400 rows takes about 10-15 seconds on my relatively modern PC. Takes even longer testers' machines. Is there anything I can do to speed up this code? Or is interop just inherently slow?

    Read the article

  • Does having a longer string in a SQL Like expression allow hinder or help query executing speed?

    - by Allain Lalonde
    I have a db query that'll cause a full table scan using a like clause and came upon a question I was curious about... Which of the following should run faster in Mysql or would they both run at the same speed? Benchmarking might answer it in my case, but I'd like to know the why of the answer. The column being filtered contains a couple thousand characters if that's important. SELECT * FROM users WHERE data LIKE '%=12345%' or SELECT * FROM users WHERE data LIKE '%proileId=12345%' I can come up for reasons why each of these might out perform the other, but I'm curious to know the logic.

    Read the article

  • How can I speed up Netbeans Task Marker resolution?

    - by Stephen
    I'm trying to quickly navigate and fix problems in code in Netbeans, and it just takes too long. I'll fix a problem, and it will take seconds to re-compile. While this is happening, the marker remains, and all the others that depend on it will too (requiring multiple next-marker key strokes to get to a "new" problem). If I'm doing a fix that changes the number of lines (e.g. organise imports), the markers will navigate to the wrong place, even though the correct text is underlined. Is there a way to speed this up? I presume it's because it's doing a full file compilation via javac to calculate the markers. BUT the information is available in netbeans, because the correct text is underlined, even when the compilation occurs.

    Read the article

  • Tips for measuring the parallelism speed-up in multi-core development.

    - by fnCzar
    I have read many of the good questions and answers around multi-core programming how-tos etc. I am familiar with concurrency, IPC, MPI etc but what I need is advice on how to measure speed-up which will help in making a business case of spending the time to write such code. Please don't answer with "well run it with single-core code then multi-core code and figure out the difference". This is neither a scientific nor a reliable way to measure performance improvement. If you know of tools that will do some of the heavy lifting please mention them. Answers pertaining to methodology will be more fitting but listing tools is ok as well.

    Read the article

  • What is the most suitable for writing a high speed server C, C++ or C# ?

    - by wniroshan
    I'm goint to write a server which does lots of image processing. Server-end processsing is expected to be very tedious. Server will maily have mobile phones as its clients. I am really concerend about speed and effciency. Security is pretty important too. Server will be running on a windows platform. Can anyone tell me what should I use as the language C, C++ or C#? or at least what are the ares that I should be looking at when selecting one of them Thank you.

    Read the article

  • Can I get sensible labels for lm-sensors output for "applesmc-isa-0300"?

    - by TK Kocheran
    2011 8,3 Macbook Pro running 64bit 11.10. When I run sensors from the lm-sensors package, I get a lot of information, but no way to understand it: coretemp-isa-0000 Adapter: ISA adapter Physical id 0: +53.0°C (high = +86.0°C, crit = +100.0°C) Core 0: +53.0°C (high = +86.0°C, crit = +100.0°C) Core 1: +52.0°C (high = +86.0°C, crit = +100.0°C) Core 2: +50.0°C (high = +86.0°C, crit = +100.0°C) Core 3: +49.0°C (high = +86.0°C, crit = +100.0°C) applesmc-isa-0300 Adapter: ISA adapter Left side : 2001 RPM (min = 2000 RPM) Right side : 2001 RPM (min = 2000 RPM) TB0T: +33.2°C TB1T: +33.2°C TB2T: +29.0°C TC0C: +52.8°C TC0D: +47.2°C TC0E: +51.8°C TC0F: +53.0°C TC0J: +1.0°C TC0P: +44.5°C TC1C: +52.0°C TC2C: +52.0°C TC3C: +52.0°C TC4C: +52.0°C TCFC: +0.2°C TCGC: +51.0°C TCSA: +52.0°C TCTD: +0.0°C TG0D: +44.5°C TG0P: +43.2°C THSP: +37.5°C TM0S: +57.5°C TMBS: +0.0°C TP0P: +50.0°C TPCD: +55.0°C The core temp info is really useful and I'm pretty sure that Left/Right Side refers to the two fans within, but otherwise, I have no idea what this information means. Is there something I can use to normalize this information?

    Read the article

  • How to stop fan running always on Asus P8P76LE motherboard with ATI Radeon HD6900

    - by Chris Good
    I'm using Ubuntu 12.04 LTS. I'm not sure if it is the CPU (i7) fan or the video card fan. I've tried using lm-sensors & fancontrol sudo sensors-detect Now follows a summary of the probes I have just done. Just press ENTER to continue: Driver `w83627ehf': * ISA bus, address 0x290 Chip `Nuvoton NCT6776F Super IO Sensors' (confidence: 9) Driver `coretemp': * Chip `Intel digital thermal sensor' (confidence: 9) To load everything that is needed, add this to /etc/modules: # Chip drivers coretemp w83627ehf Like many people, I'm also getting error: /usr/sbin/pwmconfig: There are no pwm-capable sensor modules installed Here is the output of sensors: # sensors radeon-pci-0100 Adapter: PCI adapter temp1: +71.0°C coretemp-isa-0000 Adapter: ISA adapter Physical id 0: +44.0°C (high = +80.0°C, crit = +98.0°C) Core 0: +44.0°C (high = +80.0°C, crit = +98.0°C) Core 1: +40.0°C (high = +80.0°C, crit = +98.0°C) Core 2: +43.0°C (high = +80.0°C, crit = +98.0°C) Core 3: +42.0°C (high = +80.0°C, crit = +98.0°C) I'm hoping some-one has already solved this for my configuration because this seems to be a problem for many people and there are many different suggestions.

    Read the article

  • How to stop fan running always on Asus P8P67LE motherboard with ATI Radeon HD6900

    - by Chris Good
    I'm using Ubuntu 12.04 LTS. I'm not sure if it is the CPU (i7) fan or the video card fan. I've tried using lm-sensors & fancontrol sudo sensors-detect Now follows a summary of the probes I have just done. Just press ENTER to continue: Driver `w83627ehf': * ISA bus, address 0x290 Chip `Nuvoton NCT6776F Super IO Sensors' (confidence: 9) Driver `coretemp': * Chip `Intel digital thermal sensor' (confidence: 9) To load everything that is needed, add this to /etc/modules: # Chip drivers coretemp w83627ehf Like many people, I'm also getting error: /usr/sbin/pwmconfig: There are no pwm-capable sensor modules installed Here is the output of sensors: # sensors radeon-pci-0100 Adapter: PCI adapter temp1: +71.0°C coretemp-isa-0000 Adapter: ISA adapter Physical id 0: +44.0°C (high = +80.0°C, crit = +98.0°C) Core 0: +44.0°C (high = +80.0°C, crit = +98.0°C) Core 1: +40.0°C (high = +80.0°C, crit = +98.0°C) Core 2: +43.0°C (high = +80.0°C, crit = +98.0°C) Core 3: +42.0°C (high = +80.0°C, crit = +98.0°C) I'm hoping some-one has already solved this for my configuration because this seems to be a problem for many people and there are many different suggestions.

    Read the article

  • Sharing Bandwidth and Prioritizing Realtime Traffic via HTB, Which Scenario Works Better?

    - by Mecki
    I would like to add some kind of traffic management to our Internet line. After reading a lot of documentation, I think HFSC is too complicated for me (I don't understand all the curves stuff, I'm afraid I will never get it right), CBQ is not recommend, and basically HTB is the way to go for most people. Our internal network has three "segments" and I'd like to share bandwidth more or less equally between those (at least in the beginning). Further I must prioritize traffic according to at least three kinds of traffic (realtime traffic, standard traffic, and bulk traffic). The bandwidth sharing is not as important as the fact that realtime traffic should always be treated as premium traffic whenever possible, but of course no other traffic class may starve either. The question is, what makes more sense and also guarantees better realtime throughput: Creating one class per segment, each having the same rate (priority doesn't matter for classes that are no leaves according to HTB developer) and each of these classes has three sub-classes (leaves) for the 3 priority levels (with different priorities and different rates). Having one class per priority level on top, each having a different rate (again priority won't matter) and each having 3 sub-classes, one per segment, whereas all 3 in the realtime class have highest prio, lowest prio in the bulk class, and so on. I'll try to make this more clear with the following ASCII art image: Case 1: root --+--> Segment A | +--> High Prio | +--> Normal Prio | +--> Low Prio | +--> Segment B | +--> High Prio | +--> Normal Prio | +--> Low Prio | +--> Segment C +--> High Prio +--> Normal Prio +--> Low Prio Case 2: root --+--> High Prio | +--> Segment A | +--> Segment B | +--> Segment C | +--> Normal Prio | +--> Segment A | +--> Segment B | +--> Segment C | +--> Low Prio +--> Segment A +--> Segment B +--> Segment C Case 1 Seems like the way most people would do it, but unless I don't read the HTB implementation details correctly, Case 2 may offer better prioritizing. The HTB manual says, that if a class has hit its rate, it may borrow from its parent and when borrowing, classes with higher priority always get bandwidth offered first. However, it also says that classes having bandwidth available on a lower tree-level are always preferred to those on a higher tree level, regardless of priority. Let's assume the following situation: Segment C is not sending any traffic. Segment A is only sending realtime traffic, as fast as it can (enough to saturate the link alone) and Segment B is only sending bulk traffic, as fast as it can (again, enough to saturate the full link alone). What will happen? Case 1: Segment A-High Prio and Segment B-Low Prio both have packets to send, since A-High Prio has the higher priority, it will always be scheduled first, till it hits its rate. Now it tries to borrow from Segment A, but since Segment A is on a higher level and Segment B-Low Prio has not yet hit its rate, this class is now served first, till it also hits the rate and wants to borrow from Segment B. Once both have hit their rates, both are on the same level again and now Segment A-High Prio is going to win again, until it hits the rate of Segment A. Now it tries to borrow from root (which has plenty of traffic spare, as Segment C is not using any of its guaranteed traffic), but again, it has to wait for Segment B-Low Prio to also reach the root level. Once that happens, priority is taken into account again and this time Segment A-High Prio will get all the bandwidth left over from Segment C. Case 2: High Prio-Segment A and Low Prio-Segment B both have packets to send, again High Prio-Segment A is going to win as it has the higher priority. Once it hits its rate, it tries to borrow from High Prio, which has bandwidth spare, but being on a higher level, it has to wait for Low Prio-Segment B again to also hit its rate. Once both have hit their rate and both have to borrow, High Prio-Segment A will win again until it hits the rate of the High Prio class. Once that happens, it tries to borrow from root, which has again plenty of bandwidth left (all bandwidth of Normal Prio is unused at the moment), but it has to wait again until Low Prio-Segment B hits the rate limit of the Low Prio class and also tries to borrow from root. Finally both classes try to borrow from root, priority is taken into account, and High Prio-Segment A gets all bandwidth root has left over. Both cases seem sub-optimal, as either way realtime traffic sometimes has to wait for bulk traffic, even though there is plenty of bandwidth left it could borrow. However, in case 2 it seems like the realtime traffic has to wait less than in case 1, since it only has to wait till the bulk traffic rate is hit, which is most likely less than the rate of a whole segment (and in case 1 that is the rate it has to wait for). Or am I totally wrong here? I thought about even simpler setups, using a priority qdisc. But priority queues have the big problem that they cause starvation if they are not somehow limited. Starvation is not acceptable. Of course one can put a TBF (Token Bucket Filter) into each priority class to limit the rate and thus avoid starvation, but when doing so, a single priority class cannot saturate the link on its own any longer, even if all other priority classes are empty, the TBF will prevent that from happening. And this is also sub-optimal, since why wouldn't a class get 100% of the line's bandwidth if no other class needs any of it at the moment? Any comments or ideas regarding this setup? It seems so hard to do using standard tc qdiscs. As a programmer it was such an easy task if I could simply write my own scheduler (which I'm not allowed to do).

    Read the article

  • dmidecode showing more ram slots than available?

    - by Jestep
    I have some failing RAM in a server and I ran dmidecode to figure out what tyoe of RAM I needed to replace it with. The server has 6 RAM slots, 4 of which are in use. When I run dmidecode this is what I get. dmidecode 2.10 SMBIOS 2.4 present. Handle 0x001F, DMI type 17, 27 bytes Memory Device Array Handle: 0x001E Error Information Handle: No Error Total Width: 72 bits Data Width: 64 bits Size: 2048 MB Form Factor: DIMM Set: 1 Locator: JXXX Bank Locator: DIMM 00 Type: DDR2 Type Detail: Synchronous Speed: 667 MHz Manufacturer: Not Specified Serial Number: Not Specified Asset Tag: Not Specified Part Number: Not Specified Handle 0x0020, DMI type 17, 27 bytes Memory Device Array Handle: 0x001E Error Information Handle: No Error Total Width: 72 bits Data Width: 64 bits Size: 2048 MB Form Factor: DIMM Set: 1 Locator: JXXX Bank Locator: DIMM 01 Type: DDR2 Type Detail: Synchronous Speed: 667 MHz Manufacturer: Not Specified Serial Number: Not Specified Asset Tag: Not Specified Part Number: Not Specified Handle 0x0021, DMI type 17, 27 bytes Memory Device Array Handle: 0x001E Error Information Handle: No Error Total Width: Unknown Data Width: Unknown Size: No Module Installed Form Factor: DIMM Set: 1 Locator: JXXX Bank Locator: DIMM 02 Type: DDR2 Type Detail: Synchronous Speed: 667 MHz Manufacturer: Not Specified Serial Number: Not Specified Asset Tag: Not Specified Part Number: Not Specified Handle 0x0022, DMI type 17, 27 bytes Memory Device Array Handle: 0x001E Error Information Handle: No Error Total Width: Unknown Data Width: Unknown Size: No Module Installed Form Factor: DIMM Set: 1 Locator: JXXX Bank Locator: DIMM 03 Type: DDR2 Type Detail: Synchronous Speed: 667 MHz Manufacturer: Not Specified Serial Number: Not Specified Asset Tag: Not Specified Part Number: Not Specified Handle 0x0023, DMI type 17, 27 bytes Memory Device Array Handle: 0x001E Error Information Handle: No Error Total Width: 72 bits Data Width: 64 bits Size: 2048 MB Form Factor: DIMM Set: 1 Locator: JXXX Bank Locator: DIMM 10 Type: DDR2 Type Detail: Synchronous Speed: 667 MHz Manufacturer: Not Specified Serial Number: Not Specified Asset Tag: Not Specified Part Number: Not Specified Handle 0x0024, DMI type 17, 27 bytes Memory Device Array Handle: 0x001E Error Information Handle: No Error Total Width: 72 bits Data Width: 64 bits Size: 2048 MB Form Factor: DIMM Set: 1 Locator: JXXX Bank Locator: DIMM 11 Type: DDR2 Type Detail: Synchronous Speed: 667 MHz Manufacturer: Not Specified Serial Number: Not Specified Asset Tag: Not Specified Part Number: Not Specified Handle 0x0025, DMI type 17, 27 bytes Memory Device Array Handle: 0x001E Error Information Handle: No Error Total Width: Unknown Data Width: Unknown Size: No Module Installed Form Factor: DIMM Set: 1 Locator: JXXX Bank Locator: DIMM 12 Type: DDR2 Type Detail: Synchronous Speed: 667 MHz Manufacturer: Not Specified Serial Number: Not Specified Asset Tag: Not Specified Part Number: Not Specified Handle 0x0026, DMI type 17, 27 bytes Memory Device Array Handle: 0x001E Error Information Handle: No Error Total Width: Unknown Data Width: Unknown Size: No Module Installed Form Factor: DIMM Set: 1 Locator: JXXX Bank Locator: DIMM 13 Type: DDR2 Type Detail: Synchronous Speed: 667 MHz Manufacturer: Not Specified Serial Number: Not Specified Asset Tag: Not Specified Part Number: Not Specified Does anyone know why it would show 8 slots, with 4 empty instead of 6 slots with 2 empty? Also, but my records and by other tools, the server has 16Gb and not 8Gb in it currently. grep MemTotal /proc/meminfo MemTotal: 16435808 kB The board is a Tyan S5372-LC, running CentOS 5.4 x64. Also, my error log is showing errors in bank 6. Is there any way to determine which slot bank 6 is in via: dmidecode?

    Read the article

  • Why apcupsd won't see the UPS connected to the USB posrt on FreeBSD 8.0 amd64

    - by Max Kosyakov
    Hello, Recently I installed an apcusbd on a FreeBSD 8.0 amd64 box via ports system. It installed perfectly but it won't run. Here what is says in the log: FATAL ERROR in generic-usb.c at line 636 Cannot find UPS device It appeared that HID driver picked the /dev/ugen4.2 which could cause the apcusb being unable to find the device. After I had discovered this, I rebuilt the kernel and removed the hid driver. Now it just shows "ugen4.2: <Tripp Lite> at usbus4" and no uhid0 device appears. Nevertheless the problem persisted. I tried to leave the DEVICE config setting blank --- won't help. Then I specified the particular device in the config, but it did not help either. Below you is the output of several commands that can provide some useful information on my case. server# /usr/local/etc/rc.d/apcupsd start Starting apcupsd. server# tail /var/log/messages | grep apcupsd Jun 17 22:30:00 server apcupsd[1520]: apcupsd FATAL ERROR in generic-usb.c at line 636 Cannot find UPS device -- For a link to detailed USB trouble shooting information, please see . Jun 17 22:30:00 server apcupsd[1520]: apcupsd error shutdown completed server# cat /usr/local/etc/apcupsd/apcupsd.conf ## apcupsd.conf v1.1 ## UPSCABLE usb UPSTYPE usb DEVICE /dev/ugen4.2 LOCKFILE /var/lock UPSCLASS standalone UPSMODE disable server# dmesg | grep '^u' uhci0: port 0xa800-0xa81f irq 16 at device 26.0 on pci0 uhci0: [ITHREAD] uhci0: LegSup = 0x0f00 usbus0: on uhci0 uhci1: port 0xa880-0xa89f irq 21 at device 26.1 on pci0 uhci1: [ITHREAD] uhci1: LegSup = 0x0f00 usbus1: on uhci1 uhci2: port 0xac00-0xac1f irq 18 at device 26.2 on pci0 uhci2: [ITHREAD] uhci2: LegSup = 0x0f00 usbus2: on uhci2 usbus3: EHCI version 1.0 usbus3: on ehci0 uhci3: port 0xa080-0xa09f irq 23 at device 29.0 on pci0 uhci3: [ITHREAD] uhci3: LegSup = 0x0f00 usbus4: on uhci3 uhci4: port 0xa400-0xa41f irq 19 at device 29.1 on pci0 uhci4: [ITHREAD] uhci4: LegSup = 0x0f00 usbus5: on uhci4 uhci5: port 0xa480-0xa49f irq 18 at device 29.2 on pci0 uhci5: [ITHREAD] uhci5: LegSup = 0x0f00 usbus6: on uhci5 usbus7: EHCI version 1.0 usbus7: on ehci1 uart0: port 0x3f8-0x3ff irq 4 flags 0x10 on acpi0 uart0: [FILTER] usbus0: 12Mbps Full Speed USB v1.0 usbus1: 12Mbps Full Speed USB v1.0 usbus2: 12Mbps Full Speed USB v1.0 usbus3: 480Mbps High Speed USB v2.0 usbus4: 12Mbps Full Speed USB v1.0 usbus5: 12Mbps Full Speed USB v1.0 usbus6: 12Mbps Full Speed USB v1.0 usbus7: 480Mbps High Speed USB v2.0 ugen0.1: at usbus0 uhub0: on usbus0 ugen1.1: at usbus1 uhub1: on usbus1 ugen2.1: at usbus2 uhub2: on usbus2 ugen3.1: at usbus3 uhub3: on usbus3 ugen4.1: at usbus4 uhub4: on usbus4 ugen5.1: at usbus5 uhub5: on usbus5 ugen6.1: at usbus6 uhub6: on usbus6 ugen7.1: at usbus7 uhub7: on usbus7 uhub0: 2 ports with 2 removable, self powered uhub1: 2 ports with 2 removable, self powered uhub2: 2 ports with 2 removable, self powered uhub4: 2 ports with 2 removable, self powered uhub5: 2 ports with 2 removable, self powered uhub6: 2 ports with 2 removable, self powered uhub3: 6 ports with 6 removable, self powered uhub7: 6 ports with 6 removable, self powered ugen4.2: at usbus4 server#

    Read the article

  • usb flash drives how to fix ?

    - by madyotto
    Hi all I have recently purchased some so called 256gb Kingston drives that are fake I used a program called check flash and few other to check for dead sectors and read speed and read and write speed the results are as follows: they were reading at 1.35 mbps at best they read and wrote at 0.95 mbps and had a hell of a lot of dead sectors so what I ask is: Is there a way to drop the size to improve speed Is there any other way to improve speed How can I stop the device from addressing the dead sectors Any help will be much appreciated ALL THE THANKS (MADYOTTO)

    Read the article

  • I would like to build an app that alerts me when road traffic is high or low. Where can I get the r

    - by MedicineMan
    I'm sitting at work, waiting for traffic to die down. The thought occurred to me. I know when I want to go home, why don't I have an app that watches traffic for me? I also know that there are a lot of smart people on stackoverflow. Where can I get live traffic data for the san francisco bay area region? The data source should be timely, accurate, and as high resolution as possible. I would like to build an app on top of a service, rather than watch google maps or watch another website. I would prefer that I not have to scrape the data, but I have been know to do this in the past when no other option exists.

    Read the article

  • What is a good Very-High level UI framework for JavaScript?

    - by Robert Gould
    I need to write a temporary Web-based graphical front-end for a custom server system. In this case performance and scalability aren't issues, since at most 10 people may check the system simultaneously. Also it should be PHP or Python (server) & JavaScript (client) (can't use Flex or Silverlight for very specific non-programming related issues). So I know I could use YUI or jQuery, but was wondering if there is something even more high-level that would say allow me to write such a little project within a few hours of work, and get done with it. Basically I want to be as lazy as possible (this is throw-away code anyways) and get the job done in as little time as possible. Any suggestions?

    Read the article

  • What's the proper technical term for "high ascii" characters?

    - by moodforaday
    What is the technically correct way of referring to "high ascii" or "extended ascii" characters? I don't just mean the range of 128-255, but any character beyond the 0-127 scope. Often they're called diacritics, accented letters, sometimes casually referred to as "national" or non-English characters, but these names are either imprecise or they cover only a subset of the possible characters. What correct, precise term that will programmers immediately recognize? And what would be the best English term to use when speaking to a non-technical audience?

    Read the article

  • java System.nanoTime is really slow. Is it possible to implement a high performance java profiler?

    - by willpowerforever
    I did a test and found the overhead of a function call to System.nanoTime() is at least 500 ns on my machine. Seemed that it is very hard to have a high performance java profiler. For enterprise software, suppose a function takes about 350 seconds and has 12,500,000,000 times of method calls. Therefore, the number of calls to System.nanoTime() is: 12,500,000,000 * 2 = 25,000,000,000 (one for start timestamp, one for end timestamp) And the overhead of System.nanoTime in total is: 500 ns * 25,000,000,000 = 500 * 25000 s = 12500000s. Note: all data from real case. Any better way to acquire the timestamp?

    Read the article

  • Ways to divide the high/low byte from a 16bit address?

    - by Grissiom
    Hello, I'm developing a software on 8051 processor. A frequent job is to divide the high and low byte of a 16bit address. I want to see there are how many ways to achieve it. The ways I come up so far are: (say ptr is a 16bit pointer, and int is 16bit int) ADDH = (unsigned int) ptr >> 8; ADDL = (unsigned int) ptr & 0x00FF; and ADDH = ((unsigned char *)&ptr)[0]; ADDL = ((unsigned char *)&ptr)[1]; Does anyone have any other bright ideas? ;) And anyone can tell me which way is more efficient?

    Read the article

  • C#: how to update winform from thread?

    - by JackN
    A C# thread (Read()) causes System.NotSupportedException when it tries to update a winform based on received content. The full error message is Read() System.NotSupportedException: An error message cannot be displayed because an optional resource assembly containing it cannot be found at Microsoft.AGL.Common.MISC.HandelAr() at System.Windows.Forms.ProgressBar._SetInfo() at System.Windows.Forms.ProgressBar.set_Value() at ...ProcessStatus() at ...Read() The Build/Target Environment is: Microsoft.NET\SDK\CompactFramework\v2.0\WindowsCE. Is the problem writing to the ProgressBar from a Thread? If so, what is the correct C#/winforms method to update a ProgressBar from a Thread? In this application the Read() Thread is continuous: it is started when the application starts and runs forever. void ProcessStatus(byte[] status) { Status.Speed = status[5]; var Speed = Status.Speed/GEAR_RATIO; Status.Speed = (int) Speed; progressBarSpeed.Value = Status.Speed; ...

    Read the article

< Previous Page | 104 105 106 107 108 109 110 111 112 113 114 115  | Next Page >