Search Results

Search found 3463 results on 139 pages for 'physical'.

Page 123/139 | < Previous Page | 119 120 121 122 123 124 125 126 127 128 129 130  | Next Page >

  • Spanning-tree setup with incompatible switches

    - by wfaulk
    I have a set of eight HP ProCurve 2910al-48G Ethernet switches at my datacenter that are set up in a star topology with no physical loops. I want to partially mesh the switches for redundancy and manage the loops with a spanning-tree protocol. However, our connection to the datacenter is provided by two uplinks, each to a Cisco 3750. The datacenter's switches are handling the redundant connection using PVST spanning-tree, which is a Cisco-proprietary spanning-tree implementation that my HP switches do not support. It appears that my switches are not participating in the datacenter's spanning-tree domain, but are blindly passing the BPDUs between the two switchports on my side, which enables the datacenter's switches to recognize the loop and put one of the uplinks into the Blocking state. This is somewhat supposition, but I can confirm that, while my switches say that both of the uplink ports are forwarding, only one is passing any real quantity of data. (I am assuming that I cannot get the datacenter to move away from PVST. I don't know that I'd want them to make that significant of a change anyway.) The datacenter has also sent me this output from their switches (which I have expurgated of any identifiable info): 3750G-1#sh spanning-tree vlan nnn VLAN0nnn Spanning tree enabled protocol ieee Root ID Priority 10 Address 00d0.0114.xxxx Cost 4 Port 5 (GigabitEthernet1/0/5) Hello Time 2 sec Max Age 20 sec Forward Delay 15 sec Bridge ID Priority 32mmm (priority 32768 sys-id-ext nnn) Address 0018.73d3.yyyy Hello Time 2 sec Max Age 20 sec Forward Delay 15 sec Aging Time 300 sec Interface Role Sts Cost Prio.Nbr Type ------------------- ---- --- --------- -------- -------------------------------- Gi1/0/5 Root FWD 4 128.5 P2p Gi1/0/6 Altn BLK 4 128.6 P2p Gi1/0/8 Altn BLK 4 128.8 P2p and: 3750G-2#sh spanning-tree vlan nnn VLAN0nnn Spanning tree enabled protocol ieee Root ID Priority 10 Address 00d0.0114.xxxx Cost 4 Port 6 (GigabitEthernet1/0/6) Hello Time 2 sec Max Age 20 sec Forward Delay 15 sec Bridge ID Priority 32mmm (priority 32768 sys-id-ext nnn) Address 000f.f71e.zzzz Hello Time 2 sec Max Age 20 sec Forward Delay 15 sec Aging Time 300 sec Interface Role Sts Cost Prio.Nbr Type ------------------- ---- --- --------- -------- -------------------------------- Gi1/0/1 Desg FWD 4 128.1 P2p Gi1/0/5 Altn BLK 4 128.5 P2p Gi1/0/6 Root FWD 4 128.6 P2p Gi1/0/8 Desg FWD 4 128.8 P2p The uplinks to my switches are on Gi1/0/8 on both of their switches. The uplink ports are configured with a single tagged VLAN. I am also using a number of other tagged VLANs in my switch infrastructure. And, to be clear, I am passing the tagged VLAN I'm receiving from the datacenter to other ports on other switches in my infrastructure. My question is: how do I configure my switches so that I can use a spanning tree protocol inside my switch infrastructure without breaking the datacenter's spanning tree that I cannot participate in?

    Read the article

  • 2 Servers setup for redundency, backup

    - by minal
    I presently have 1 dedicated virtual server running my website/blog/mail, etc. This is on Hyper-V with 512MB RAM. Windows Web2008. With the VM, I have these running within it: SmarterMail – for emails MS DNS – I have my own nameservers on this server SQL Express IIS7 2 IP Address I have now leased 2 physical servers : P4 2.6Ghz 1GB RAM 80GB HDD. With these new servers, I get 2 IPs per server as well. These are running Windows 2008 Standard. With the VM the HDD was obviously on a RAID setup so I was not worried about hardware issues as it fell on the provider to manage. However, with the new servers the HDD is not RAID’d, hence my concern is that if it fails I need a backup position. What would be the most ideal setup to go for? I am thinking: Server 1: (Web/PrimaryDNS) DNS – NS1 SQL Express – OFF turn on when required, ie. Server2 is down SmarterMail – OFF turn on when required, ie. Server2 is down IIS 7 Server2:(SQL/Backup) DNS – NS2 SQL Web Edition SmarterMail IIS 7 How can I set it up so that if 1 goes down I can have everything on 2 instantly or by manual switching over. I am confused as other DNS servers will cache the web servers IP address for requests, and if that server goes down, the backup server will have a different IP. How do I make this work? I will be doing routine backups, in which case I will keep copies of backups on both servers. If I am copying the same stuff on both servers like a mirror then I am losing on using the true performance out of it. It's like 1 server is always on standby. Ideally I want SQL and web on 2 diff machines for best performance. If Server1 goes down, I should be able to switch to Server2 fairly easily. I don't have a problem with manual intervention to start the sql/mail services, etc. In terms of scalabilty, the VM has coped pretty well to date. Moving forward the SQL and IIS workload is going to double pretty quickly. Some ideas would be great.

    Read the article

  • How to troubleshoot performance issues of PHP, MySQL and generic I/O

    - by jbx
    I have a WordPress based website running on a shared hosting. Its response time is very decent (around 2s to retrieve the HTML page and 5s to load all the resources). I was planning to move it to a dedicated virtual server (Ubuntu 12.04 LTS), which should theoretically improve things and make them more consistent given its not shared. However I observed severe performance degredation, with the page taking 10seconds to be generated. I ruled out network issues by editing /etc/hosts on the server and mapping the domain to 127.0.0.1. I used the Apache load tester ab to get the HTML, so JS, CSS and images are all excluded. It still took 10 seconds. I have Zpanel installed on the server which also uses MySQL, and its pages come up quite fast (1.5s) and also phpMyAdmin. Performing some queries on the wordpress database directly through phpMyAdmin returns them quite fast too, with query times in the 10 to 30 millisecond region. Memory is also sufficient, with only 800Mb being used of the 1Gb physical memory available, so it doesn't seem to be a swap issue either. I have also installed APC to try to improve the PHP performance, but it didn't have any effect. What else should I look for? What could be causing this degradation in performance? Could it be some kind of I/O issue since I am running on a cloud based virtual server? I wish to be able to raise the issue with my provider but without showing actual data from some diagnosis I am afraid he will just blame my application. UPDATE with sar output (every second) when I did an HTTP request: 02:31:29 CPU %user %nice %system %iowait %steal %idle 02:31:30 all 0.00 0.00 0.00 0.00 0.00 100.00 02:31:31 all 2.22 0.00 2.22 0.00 0.00 95.56 02:31:32 all 41.67 0.00 6.25 0.00 2.08 50.00 02:31:33 all 86.36 0.00 13.64 0.00 0.00 0.00 02:31:34 all 75.00 0.00 25.00 0.00 0.00 0.00 02:31:35 all 93.18 0.00 6.82 0.00 0.00 0.00 02:31:36 all 90.70 0.00 9.30 0.00 0.00 0.00 02:31:37 all 71.05 0.00 0.00 0.00 0.00 28.95 02:31:38 all 14.89 0.00 10.64 0.00 2.13 72.34 02:31:39 all 2.56 0.00 0.00 0.00 0.00 97.44 02:31:40 all 0.00 0.00 0.00 0.00 0.00 100.00 02:31:41 all 0.00 0.00 0.00 0.00 0.00 100.00 My suspicion that this comes from I/O related issue is also because a caching plugin I use to reduce the amount of queries to the database, by precompiling PHP pages is actually making things worse instead of better. It seems that file access is making things worse instead.

    Read the article

  • High Jitter in NTP and poll value never goes above 128

    - by Aseem
    I have a lot of servers syncing to the same NTP servers (4). Not every server is in the same LAN. Some are 3 hops away from the NTP servers and some are 6 hops away. On couple of servers I see that the poll value never touches the 1024 mark and the jitter value is in double digits. Could it be due to the system hardware? These are windows servers (physical) and require as accurate time as possible. Please advice what I should do. Some of the stats that I collected manually from the bad box (which is 6 hops away from the ntp servers) C:\Program Files (x86)\NTP>ntpq -p -n remote refid st t when poll reach delay offset jitter ============================================================================== +*.*.*.25 *.*.*.233 2 u 12 128 377 1.210 -12.579 14.913 +*.*.*.26 *.*.*.233 2 u 96 128 377 1.067 -2.235 9.885 **.*.*.27 *.*.*.233 2 u 24 128 377 1.038 -7.569 11.178 +*.*.*.28 *.*.*.233 2 u 49 128 377 1.288 -11.058 14.544 remote refid st t when poll reach delay offset jitter ============================================================================== +*.*.*.25 *.*.*.233 2 u 124 128 377 0.614 -6.212 5.329 +*.*.*.26 *.*.*.233 2 u 93 128 377 0.910 -9.431 3.111 +*.*.*.27 *.*.*.233 2 u 1 128 377 0.824 -7.428 3.129 **.*.*.28 *.*.*.233 2 u 84 128 377 1.503 -8.230 3.511 remote refid st t when poll reach delay offset jitter ============================================================================== **.*.*.25 *.*.*.233 2 u 117 128 377 1.235 -4.084 11.405 +*.*.*.26 *.*.*.233 2 u 96 128 377 1.335 -11.813 13.130 +*.*.*.27 *.*.*.233 2 u 130 128 377 1.549 -14.036 16.381 -*.*.*.28 *.*.*.233 2 u 79 128 377 1.258 13.395 22.203 remote refid st t when poll reach delay offset jitter ============================================================================== **.*.*.25 *.*.*.233 2 u 88 128 377 1.235 -4.084 14.068 +*.*.*.26 *.*.*.233 2 u 63 128 377 1.335 -11.813 17.086 +*.*.*.27 *.*.*.233 2 u 103 128 377 1.549 -14.036 20.691 -*.*.*.28 *.*.*.233 2 u 47 128 377 1.258 13.395 20.231 remote refid st t when poll reach delay offset jitter ============================================================================== +*.*.*.25 *.*.*.233 2 u 47 64 377 0.652 -15.805 14.077 **.*.*.26 *.*.*.233 2 u 11 64 377 1.013 -14.423 11.375 -*.*.*.27 *.*.*.233 2 u 63 64 377 0.765 -2.030 7.680 +*.*.*.28 *.*.*.233 2 u 4 64 377 1.191 -17.980 14.393 remote refid st t when poll reach delay offset jitter ============================================================================== -*.*.*.25 *.*.*.233 2 u 3 128 377 1.576 18.665 21.999 +*.*.*.26 *.*.*.233 2 u 73 128 377 0.637 -5.012 14.405 **.*.*.27 *.*.*.233 2 u 127 128 377 0.272 -8.237 14.438 +*.*.*.28 *.*.*.233 2 u 123 128 377 1.190 -14.383 18.875 C:\Program Files (x86)\NTP>ntpdc -c loopinfo offset: -0.016430 s frequency: 7.106 ppm poll adjust: 18 watchdog timer: 133 s offset: -0.016430 s frequency: 7.106 ppm poll adjust: 18 watchdog timer: 341 s offset: -0.000149 s frequency: 6.645 ppm poll adjust: 0 watchdog timer: 383 s offset: 0.015735 s frequency: 6.725 ppm poll adjust: 7 watchdog timer: 577 s offset: -0.010331 s frequency: 6.748 ppm poll adjust: 21 watchdog timer: 567 s offset: -0.009427 s frequency: 6.687 ppm poll adjust: 28 watchdog timer: 301 s offset: -0.007361 s frequency: 6.612 ppm poll adjust: 30 watchdog timer: 155 s offset: -0.008106 s frequency: 4.358 ppm poll adjust: 30 watchdog timer: 291 s NTP.conf # NTP configuration file # Use drift file driftfile "C:\Program Files (x86)\NTP\ntp.drift" # Logs statistics loopstats peerstats clockstats statsdir "C:\Program Files (x86)\NTP\logs\" # directory for statistics files filegen peerstats file peerstats type day enable filegen loopstats file loopstats type day enable filegen clockstats file clockstats type day enable logfile "C:\Program Files (x86)\NTP\logs\syslog.txt" # Use specific NTP servers server *.*.*.25 minpoll 4 maxpoll 7 iburst server *.*.*.26 minpoll 4 maxpoll 7 iburst server *.*.*.27 minpoll 4 maxpoll 7 iburst server *.*.*.28 minpoll 4 maxpoll 7 iburst

    Read the article

  • How to specify what network interface to use with TTCP or IPERF?

    - by Sammy
    The PC has two Gigabit Ethernet ports. They function as two separate network adapters. I'm trying to do a simple loopback test between the two. I've tried TTCP and IPERF. They're giving me hard time because I'm using the same physical PC. Using pcattcp... On the receiver end: C:\PCATTCP-0114>pcattcp -r PCAUSA Test TCP Utility V2.01.01.14 (IPv4/IPv6) IP Version : IPv4 Started TCP Receive Test 0... TCP Receive Test Local Host : GIGA ************** Listening...: On TCPv4 0.0.0.0:5001 Accept : TCPv4 0.0.0.0:5001 <- 10.1.1.1:33904 Buffer Size : 8192; Alignment: 16384/0 Receive Mode: Sinking (discarding) Data Statistics : TCPv4 0.0.0.0:5001 <- 10.1.1.1:33904 16777216 bytes in 0.076 real seconds = 215578.95 KB/sec +++ numCalls: 2052; msec/call: 0.038; calls/sec: 27000.000 C:\PCATTCP-0114> On the transmitter end: C:\PCATTCP-0114>PCATTCP.exe -t 10.1.1.1 PCAUSA Test TCP Utility V2.01.01.14 (IPv4/IPv6) IP Version : IPv4 Started TCP Transmit Test 0... TCP Transmit Test Transmit : TCPv4 0.0.0.0 -> 10.1.1.1:5001 Buffer Size : 8192; Alignment: 16384/0 TCP_NODELAY : DISABLED (0) Connect : Connected to 10.1.1.1:5001 Send Mode : Send Pattern; Number of Buffers: 2048 Statistics : TCPv4 0.0.0.0 -> 10.1.1.1:5001 16777216 bytes in 0.075 real seconds = 218453.33 KB/sec +++ numCalls: 2048; msec/call: 0.037; calls/sec: 27306.667 C:\PCATTCP-0114> It's responding alright. But why does it say 0.0.0.0? Is it passing through only one of the network adapters? I want 10.1.1.1 to be the server (receiver) and 10.1.1.2 to be the client (transmitter). These are the IP addresses assigned manually to each network adapter. How do I specify these addresses in TTCP? There is also the IPERF tool which has the -B option. Unfortunately I've been only able to use this option to bind the server to the 10.1.1.1 address. I was unable to bind the client to the 10.1.1.2 address. I might be doing it wrong. Can the -B option be used for both the server as well as the client side? What does the syntax look like for the client?

    Read the article

  • Loose component cables causing HDMI video problems

    - by jwir3
    I'm not sure this is the correct forum, but I'll ask anyway. I have an A/V setup at home that has something like the following: Five Components (actually a few more, like a CD player, but they don't really relate to this question): Older Pioneer Receiver Digital Set Top Box Sony BluRay Player Samsung Plasma TV Speakers The reason for the receiver is so that all the sound can go through the speakers, rather than some going to the TV speakers and some to the external speakers. They are connected as follows: Digital Set Top Box connects via component video to Samsung TV directly via Component 2 (audio goes to Older Pioneer Receiver). Sony BluRay player is connected via HDMI 1 to TV, but audio goes to the receiver. Now, the problem I'm having is that when I have the digital set top box connected, there are times when the Netflix or Hulu streams I watch through the Sony BluRay player (it's connected to a router for internet access) will lose video. What I mean by this is that the sound of the episode will keep playing, but the screen will go black. If I jiggle the component cables, it will often come back. If I disconnect the component cables, it will always come back. I've noticed that one of the connections (the red component cable) doesn't like to sit very well in the component socket in the back of the digital set top box. It seems like there is a bad connection here, but it doesn't seem like this should be affecting the HDMI input at all. What I've noticed, though, is that when I disconnect the digital set top box completely (i.e. remove the component cable from the back of the TV), the problem seems to resolve itself. I'm not talking about actually removing the cable physically, because I thought perhaps the cables were mashing against one another, and possibly jiggling each other loose. To correct this possible problem, I took the component cable completely out of the cable ties it was in in the back of my entertainment center, as well as pulled the digital set top box out from the entertainment center altogether. It's now connected directly to the TV, without any other cables touching it to cause some kind of weird interference or just physical pulling on the cable. Same problem. If, however, I disconnect the component cable and just leave it sitting behind the TV, then the problem goes away. So, my question is this - what could be causing this? Is it a case where it's an improperly shielded component cable that's causing interference with the HDMI input, or something that's wrong with the TV? It's an intermittent problem, so it's difficult to track down. The TV isn't that old, so it's probably still under warranty. I'm just wondering if there is something else I can do that might reduce this problem without having to haul a massive television set out of my house to get repaired/replaced.

    Read the article

  • Stack-based keyboard delay using Logitech MX3100 keyboard

    - by Mark S. Rasmussen
    I've been using a Logitech Cordless Desktop MX3100 keyboard for quite a while. I've never really had any problems, except for the occasional typo. I noticed however that I tended make the typo "Laod" instead of "Load", quite a bit more often than any other typos. As it started to get on my nerves, I decided to do some testing. What I found out was than when I write lowercase "load", I'd never make the typo. All uppercase, or just uppercase L, I'd make the typo quite often. My actual (very scientific) testing is probably best described by showing the output: moatmoatmoat MoatMoatMoat loatloatloat LaotLaotLaot loafloafloaf LaofLaofLaof hoathoathoat HoatHoatHoat hoadhoadhoad HoadHoadHoad lortlortlort LrotLrotLrot What i found out was that whenever shift was depressed, typing an uppercase "L" would induce a significant lag if the next character was an "o", compared to the lag of the any other key: High "o" lag: LoLoLoLoLoLo No "a" lag: LaLaLaLaLaLa No lag for neither "o" nor "a": lolololololo lalalalalala By realizing this I regained a slight bit of sanity as I knew I wasn't coming down with a case of Parkinsons. I was actually typing correctly, the lag just interpreted it wrongly. Now, what really bugs me is that I can't fathom how this is occurring. What I'm actually typing, in physical order, is this: L - o - a - d, and yet, the "a" is output before the "o", even though "o" was pressed before "a". So while the keyboard is processing the "Lo" combo, the "a" gets prioritized and is inserted before the "o" is done processing, resulting in Laod instead of Load. And this only happens when typing "Lo", not when typing lowercase "lo". This problem could stem from the keyboard hardware, the receiver hardware or the keyboard software driver. No matter the fault location however, I can't imagine how this could be implemented as anything but a FIFO queue. A general delay, sure, I could live with that, albeit I'd be irritated. But a lag affecting different keys differently, and even resulting in unpredictable outcome - that just doesn't make any sense. I've solved the problem by just switching to a wired keyboard. I just can't shake it off me though; what kind of bug/error/scenario would result in a case like this? Edit: It's been suggested that I stop drinking Red Bull and stick to water instead. While that may actually help solve the issue, I'm really not looking for a solution as such. I'm more interested in an explanation of how this could happen, as I can't imagine any viable technical solution that could result in this behavior.

    Read the article

  • How to have Windows Server DNS use hosts file to resolve specific host names

    - by user41079
    Hello, everyone, I'm facing a small problem with Windows Server 2003 DNS service. In my corporation, I'm running Microsoft DNS server(172.16.0.12) to do name resolution to my company intranet(domain name ends in dev.nls. resolving to IP 172.16..), and it is also configured as a DNS forwarder to forward other domain names(e.g. *.google.com , *.sf.net) to Internet real DNS servers. This internal DNS server never tends to serve users from outside world. And, we are running a mail server(serving incoming mail for a real Internet domain @nlscan.com) inside company firewall which can be accessed in either way: by connecting to 172.16.0.10 from within intranet. by connecting to mail.nlscan.com(resolved to 202.101.116.9) from Internet. Note that 172.16.0.10 and 202.101.116.9 is not the same physical machine. The 202 one is a firewall machine who do port forwarding of port 25 and 110 to intranet address 172.16.0.10 . Now my question: If users inside corporate LAN want to resolve mail.nlscan.com, it resolves to 202.101.116.9. That's correct and workable, BUT NOT GOOD, because the mail traffic goes to the firewall machine then bounces to 172.16.0.10 . I hope that our internal DNS server can intercept the name mail.nlscan.com and resolve it to 172.16.0.10 . So, I hope that I can write an entry in "hosts" file on 172.16.0.12 to do this. But, how can Microsoft DNS server recognize this "hosts" file? Maybe you suggest, why not have intranet user use 172.16.0.10 to access my mail server? I have to say it is inconvenient, suppose a user(employee) works on his laptop, daytime in office and nighttime at home. When he is at home, he cannot use 172.16.0.10 . Creating a zone for nlscan.com on our internal DNS server is not feasible, because the name server for nlscan.com domain is on our ISP, and it is responsible for resolving other host names and sub-domains under nlscan.com . Thank you in advance.

    Read the article

  • Performance of ClearCase servers on VMs?

    - by Garen
    Where I work, we are in need of upgrading our ClearCase servers and it's been proposed that we move them into a new (yet-to-be-deployed) VMmare system. In the past I've not noticed a significant problem with performance with most applications when running in VMs, but given that ClearCase "speed" (i.e. dynamic-view response times) is so latency sensitive I am concerned that this will not be a good idea. VMWare has numerous white-papers detailing performance related issues based on network traffic patterns that re-inforces my hypothesis, but nothing particularly concrete for this particular use case that I can see. What I can find are various forum posts online, but which are somewhat dated, e.g.: ClearCase clients are supported on VMWare, but not for performance issues. I would never put a production server on VM. It will work but will be slower. The more complex the slower it gets. accessing or building from a local snapshot view will be the fastest, building in a remote VM stored dynamic view using clearmake will be painful..... VMWare is best used for test environments (via http://www.cmcrossroads.com/forums?func=view&catid=31&id=44094&limit=10&start=10) and: VMware + ClearCase = works but SLUGGISH!!!!!! (windows)(not for production environment) My company tried to mandate that all new apps or app upgrades needed to be on/moved VMware instances. The VMware instance could not handle the demands of ClearCase. (come to find out that I was sharing a box with a database server) Will you know what else would be on that box besides ClearCase? Karl (via http://www.cmcrossroads.com/forums?func=view&id=44094&catid=31) and: ... are still finding we can't get the performance using dynamic views to below 2.5 times that of a physical machine. Interestingly, speaking to a few people with much VMWare experience and indeed from running builds, we are finding that typically, VMWare doesn't take that much longer for most applications and about 10-20% longer has been quoted. (via http://www.cmcrossroads.com/forums?func=view&catid=31&id=44094&limit=10&start=10) Which brings me to the more direct question: Does anyone have any more recent experience with ClearCase servers on VMware (if not any specific, relevant performance advice)?

    Read the article

  • How can I prevent an unintentional DDOS running ColdFusion 8 with IIS 6?

    - by Eric Belair
    We had an interesting outage today on one of our client's websites. Out of nowhere, the website was inaccessible. The website runs by itself on a dedicated physical Windows 2000 server (probably overkill, I know, but that's a discussion for a different day). After restarting IIS and ColdFusion Application Service, the problem came back several times. My initial thought was that it was a DNS issue, which happens occasionally - the last time it happened was after Hurricane Sandy when we our ISP was out, and we had to make some network config changes. But, it was not a DNS issue. My second thought was that it was a DDOS attack, but, there's very little reason anyone would want to take this site down. When we called our ISP, the operator on the other end noted that traffic was spiking significantly. As it turned out, the client had unintentionally caused a DDOS on the website, after they FTPed a very large video file, and then mass emailed a link to it. Hundreds of people clicked the link and brought the site to its knees. I am primarily a Website Programmer, but I often have to contribute to server administration at times. Sadly, I'm the resident ColdFusion and IIS expert, but I don't have a lot of experience with this issue. What are some basic steps that I can take to prevent this from happening in the future, since we cannot always control what files the client posts to the website. Here are some ideas I had, but I'm unsure of the impact: Limit the number of connections in IIS. Put media files on a separate server (like an Amazon site, etc.). File requests of this type currently behind a server-script (i.e. /www.site.com/viewFile.cfm?fileId=1424545, where the fileId references a file off the webroot) that logs requests, and pushes the file to the browser using CFCONTENT. I could edit this script to reject requests when they exceed a certain amount in a given time-frame (i.e. a 5MB can be accessed globally 10 times in an hour). This may cause some users frustration, but, if hundreds of users are attempting to view the file, the site is going to crash anyways, as it did today, which is way more frustrating, since there is no "pretty" message explaining why they can't get to the file. I'm open to any suggestions, as I'm continuing my research to report to the CTO with the best options, so that we can put a solution into effect. Thank you.

    Read the article

  • how to read mac address with sed vs python

    - by getjoefree
    before, i can read mac with awk tools in windows or winpe, but now it don't support winpe 4.0 64-bit. i want to get this result "set mac=A4BADB9D1E8E" with python 2.6, who could help to me. thanks a lot! as follows: ipconfig -all|sed -nrf getmac.sed | sed -e "s/-//g" D:\LOG\WINMAC.BAT getmac.sed: /Realtek/ { n; s/.*: ([-0-9A-F]+)/set winmac=\1/p; } and "ipconfig -all" command log as bellows: ipconfig -all mac.log Ethernet adapter Ethernet: Media State . . . . . . . . . . . : Media disconnected Connection-specific DNS Suffix . : WKSCN.WISTRON Description . . . . . . . . . . . : Realtek PCIe FE Family Controller Physical Address. . . . . . . . . : 24-B6-FD-1F-41-E7 DHCP Enabled. . . . . . . . . . . : Yes Autoconfiguration Enabled . . . . : Yes

    Read the article

  • Linux RAID-0 performance doesn't scale up over 1 GB/s

    - by wazoox
    I have trouble getting the max throughput out of my setup. The hardware is as follow : dual Quad-Core AMD Opteron(tm) Processor 2376 16 GB DDR2 ECC RAM dual Adaptec 52245 RAID controllers 48 1 TB SATA drives set up as 2 RAID-6 arrays (256KB stripe) + spares. Software : Plain vanilla 2.6.32.25 kernel, compiled for AMD-64, optimized for NUMA; Debian Lenny userland. benchmarks run : disktest, bonnie++, dd, etc. All give the same results. No discrepancy here. io scheduler used : noop. Yeah, no trick here. Up until now I basically assumed that striping (RAID 0) several physical devices should augment performance roughly linearly. However this is not the case here : each RAID array achieves about 780 MB/s write, sustained, and 1 GB/s read, sustained. writing to both RAID arrays simultaneously with two different processes gives 750 + 750 MB/s, and reading from both gives 1 + 1 GB/s. however when I stripe both arrays together, using either mdadm or lvm, the performance is about 850 MB/s writing and 1.4 GB/s reading. at least 30% less than expected! running two parallel writer or reader processes against the striped arrays doesn't enhance the figures, in fact it degrades performance even further. So what's happening here? Basically I ruled out bus or memory contention, because when I run dd on both drives simultaneously, aggregate write speed actually reach 1.5 GB/s and reading speed tops 2 GB/s. So it's not the PCIe bus. I suppose it's not the RAM. It's not the filesystem, because I get exactly the same numbers benchmarking against the raw device or using XFS. And I also get exactly the same performance using either LVM striping and md striping. What's wrong? What's preventing a process from going up to the max possible throughput? Is Linux striping defective? What other tests could I run?

    Read the article

  • Looking for a fiber optic "switch" or "router" for home use

    - by Shrout1
    The gist of my question: What is a "fiber optic" switch called? I.E. a layer 2 ethernet switch that uses fiber TX and RX connections and sends layer 2 network traffic between the fiber strands that are connected. Can someone purchase a dedicated fiber switch that does not have copper ethernet ports? What is the current average price of a device like this? Not necessarily looking for product endorsements, just information Might not make sense to go this route if it is too cost prohibitive What type of fiber connector is used for terminating a fiber strand into a jack on the wall? Can fiber be "patched" using two jacks and a "patch" cable? Is signal loss a concern with the longest runs at 100-200ft, a patch cable and media converters? The full story: My parents had unterminated fiber optic cable and terminated Cat5e run throughout their home when it was built in 2004. 10 years later the Cat5e isn't providing the throughput that my father needs to accomplish multiple streams of HD and fast system backups throughout the house. He can't reach gigabit speeds across the distance of the Cat5e runs. We are both interested in terminating the fiber connections and using them as high speed "backbones" to copper switches in each room of the house. It would be easy to attain gigabit speeds (or better, eventually) using the fiber. I have searched and searched for a "fiber optic switch" or "fiber optic router" and cannot find the correct term to describe this piece of hardware. We can use fiber media converters at the end points of each connection, however it would be nice to have a "patch panel" set up in the network closet in the basement that has fiber connections on it and switches the ethernet streams between the connections/systems in the house. Each fiber media converter costs between $50-$100 a piece... After 10 or so terminated connections it might make sense to find a piece of hardware that does not require media converters. That would depend upon the cost of this hardware Somewhat unrelated, if we are able to route between these fiber strands successfully, what is the physical connector type used in a jack on the wall? Just like RJ45 has a wall outlet (depicted below): What is the fiber optic equivalent of this? In the interim could we "patch" a couple fiber strands together in the network closet? Would signal loss be of concern with a run length of 100-200 feet, a patch cable and two media converters? If that would work then it could be used until the funds are available for more.

    Read the article

  • Ubuntu Lucid: Erratic screen behaviour after boot

    - by fgysin
    In short: about 50% of the time I have a screwed up monitor setup after reboot. About 50% it is totally correct. Now the longer version: I updated my machine from 9.04 to 10.04 (via 9.10). At first I run into some monitor problems (I have a 3-monitor setup) because of the known bug in the new xserver driver for xinerama. This messes up behaviour if the mouse goes either left or above the screen number 0, i.e. I had to make my left-most monitor screen 0. Everything worked out fine finally, I got my 3-monitor setup back with xinerama enabled to get one big desktop streched over 3 screens. Now the fun part: Every time I start up my machine only one of the 3 monitors gets a signal and is woken up: it only recognizes the left-most monitor (screen 0) and crams all the desktop stuff into this one screen. If I go into nvidia settings I only see one physical device although all 3 are connected and have power. When I look into the xorg.conf I can still see my old setup with 3 devices, 3 screens, xinerama active etc... But I was totally unable to get 3 montitors to work. (I tried unplugging monitors, reconfiguring whole nvidia setup, ...) But it gets even better: When I restart my machine (i.e. choose the restart option from the Ubuntu menu) it shuts down and tries to restart. The restart then gets stuck after showing the Ubuntu splash screen with the 'loading bar' (the moving dots thingy) and I am forced to kill the machine by cutting power. But after the power cut the machine boots up normally and suddenly I get my 3 monitor setup back up working. That is until the next time I shut down and start up, where it all starts over again and I only have one monitor... (see above) I really have a hard time seeing where the error is. It must be that the restart boot somehow differs from the 'normal' boot. But the fact that it gets stuck and I need to cut power which then basically triggers a 'normal' boot does not really support this theory... My setup (please tell me if you need further info): 3 monitors as 3 screens as one desktop (with xinerama) 2 nvidia cards where screen 0 and 1 are on card 0 and screen 2 is on card 1 Ubuntu 10.04 Lucid Lynx (updated from 9.10, 9.04, ....) I would appreciate every idea on the subject, at the moment I really don't have any clue what to do...

    Read the article

  • Partition table is corrupt

    - by Tim
    I have a corrupt the partition table on the laptop that is running Ubunutu 10.4. Before the partition table was corrupt I had the following partitions: 2 primary partitions: 1st - NTFS 2nd - Extended 4 logical partitons that are built within 2nd extended: 1st NTFS (68 Gib) 2nd Linux (19 Gib) 3rd Swap (1.4 Gib) 4th Linux (24 Gib) The physical order of these partitions was the following: ( 4th Linux ) - ( 1st NTFS ) - ( 2nd Linux ) - ( 3rd Swap ) The logical order of the partition was different: ( 1st NTFS ) - ( 2nd Linux ) - ( 3rd Swap ) ( 4th Linux ) NTFS partition was big and it resided between 2 Linux partitions, neither of these partitions had enough space to install Oracle 11g for my project with prof. Gamper and Markus Innerebner. Therefore, I decided to a) either move the NTFS partion to the left or b) remove it completely and extend partition where Linux resides. As I tool I have chosen GParted. But unfortunately it was not able to move the partition because he found that in NTFS partition there are some blocks that are referenced multiple times. Also it was not able to remove the partition neither, because in this case the partitions that follow it ( 2nd Linux ) - ( 3rd Swap ) have to be in his opinion also removed, because the organization of extended partition is a linked list. Since GParted was not able to do such thing I was trying to find another tool. I found diskdrake tool on PSLinuxOS distribution of linux. That tool silently deleted ( 1st NTFS ) partition and I thought that everything was fine. But diskdrake has damaged the partition in a way that I am not able either to boot from the hard disk nor to see the partitions with GParted and even with diskdrake itself! Fortunately I have a live CD of Ubuntu 8.10 and I am able to boot and see hard disk. I have 2 ideas how I can solve the problem: 1) Manually change disk partitions and point them to the correct partitions. 2) Create partition table with GParted that as much as possible is the same with the previous one I find the 2nd approach less time consuming but some data will be lost because of it is not possible to place borders of the partitions exactly how it was before. And moreover I am not sure if such approach would work, for example, if the OS is able to locate files after repartitioning. I feel like that it will but not 100% sure. Are there some ideas how the problem may be solved?

    Read the article

  • Best Processor for MediaSmart Server?

    - by Kent Boogaart
    I'm trying to figure out what the best possible processor is that I can stick in my HP MediaSmart server. I'm clueless when it comes to correlating CPUs to motherboards. I suspect it's the socket type I care about, but I worry that there's more to it. CPU-Z gives me (excerpt): Processors Information ------------------------------------------------------------------------- Processor 1 ID = 0 Number of cores 1 (max 1) Number of threads 1 (max 1) Name AMD Sempron LE-1150 Codename Sparta Specification AMD Sempron(tm) Processor LE-1150 Package Socket AM2 (940) CPUID F.F.1 Extended CPUID F.7F Brand ID 1 Core Stepping DH-G1 Technology 65 nm Core Speed 1000.0 MHz Multiplier x FSB 5.0 x 200.0 MHz HT Link speed 800.0 MHz Stock frequency 2000 MHz Instructions sets MMX (+), 3DNow! (+), SSE, SSE2, SSE3, x86-64 L1 Data cache 64 KBytes, 2-way set associative, 64-byte line size L1 Instruction cache 64 KBytes, 2-way set associative, 64-byte line size L2 cache 256 KBytes, 16-way set associative, 64-byte line size FID/VID Control yes Max FID 10.0x Max VID 1.350 V P-State FID 0x2 - VID 0x12 (5.0x - 1.100 V) P-State FID 0xA - VID 0x0C (9.0x - 1.250 V) P-State FID 0xC - VID 0x0A (10.0x - 1.300 V) K8 Thermal sensor yes K8 Revision ID 6.0 Attached device PCI device at bus 0, device 24, function 0 Attached device PCI device at bus 0, device 24, function 1 Attached device PCI device at bus 0, device 24, function 2 Attached device PCI device at bus 0, device 24, function 3 Chipset ------------------------------------------------------------------------- Northbridge SiS 761GX rev. 02 Southbridge SiS 966 rev. 59 Graphic Interface AGP AGP Revision 3.0 AGP Transfer Rate 8x AGP SBA supported, enabled Memory Type DDR2 Memory Size 2048 MBytes Channels Single Memory Frequency 200.0 MHz (CPU/5) CAS# latency (CL) 5.0 RAS# to CAS# delay (tRCD) 5 RAS# Precharge (tRP) 5 Cycle Time (tRAS) 15 Bank Cycle Time (tRC) 21 Command Rate (CR) 1T DMI ------------------------------------------------------------------------- DMI BIOS vendor Phoenix Technologies, LTD version R03 date 05/08/2008 DMI System Information manufacturer HP product MediaSmart Server version unknown serial CN68330DGH UUID A482007B-B0CC7593-DD11736A-407B7067 DMI Baseboard vendor Wistron model SJD4 revision A.0 serial unknown DMI System Enclosure manufacturer HP chassis type Desktop chassis serial unknown DMI Processor manufacturer AMD model AMD Sempron(tm) Processor LE-1150 clock speed 2000.0 MHz FSB speed 200.0 MHz multiplier 10.0x DMI Memory Controller correction 64-bit ECC Max module size 4096 MBytes DMI Memory Module designation A0 size 2048 MBytes (double bank) DMI Memory Module designation A1 DMI Memory Module designation A2 DMI Memory Module designation A3 DMI Port Connector designation PS/2 Mouse (internal) port type Mouse Port connector PS/2 connector PS/2 DMI Port Connector designation USB0 (external) port type USB DMI Physical Memory Array location Motherboard usage System Memory correction None max capacity 16384 MBytes max# of devices 4 DMI Memory Device designation A0 format DIMM type unknown total width 64 bits data width 64 bits size 2048 MBytes DMI Memory Device designation A1 format DIMM type unknown total width 64 bits data width 64 bits DMI Memory Device designation A2 format DIMM type unknown total width 64 bits data width 64 bits DMI Memory Device designation A3 format DIMM type unknown total width 64 bits data width 64 bits How do I figure out what options I have for an upgrade?

    Read the article

  • Is real-time or synchronous replication possible over WAN link?

    - by johnnyb10
    The company I work for is looking to implement truly real-time file replication with file locking over a WAN link that spans over 2000 miles. We currently have a 16-drive SAN setup in our east coast office. We also have an office out in Colorado that will have the same exact SAN setup. The idea is to have those two SANs contain the same exact data at all times, which will allow us to work with the same data pool, and which will also provide use with an offsite backup solution, should a failure occur on either end. We're running Server 2008. The objective is to enable users in the east coast office to work on files and have those changes be instantly updated on the Colorado SAN as well. We also need there to be file locking so that there will be no conflicts or overwritten changes if users attempt to work on the same file. Is this scenario even possible, at speeds that would make the files usable? And if so, what software would we need to pull this off? As I understand it, DFS-R does not provide file locking, so if we used that, we would need to go with a third-party product like Peerlock. But I don't even know if DFS-R is an option. Can it replicate quickly enough over a WAN link? Can any product? It seems that if we were to use synchronous replication, the programs would be unacceptably slow, as every write would have to wait for confirmation from the other end of the link. But if we used asynchronous replication, what kind of latency would we be looking at? There is a product from GlobalScape called WAFS that claims to provide "File coherence with real-time file locking, file release, and synchronization" and says that "As files are modified, changes are mirrored instantly using intelligent byte-level differencing to minimize the impact on network bandwidth". So this sounds like synchronous replication, but that doesn't even seem possible, given physical limitations such as the speed of light. If anyone has any experience with this kind of setup, or knows whether it's even possible, I'd appreciate your input and suggestions, including recommendations for software that we should check out.

    Read the article

  • How can I repair my USB drive?

    - by yurko
    USB drive is in read only state and I can't repair it. First of all I tried erase it using dd: root@yurko-laptop:/home/yurko-laptop# ls -l /dev/disk/by-id | grep usb lrwxrwxrwx 1 root root 9 ??? 18 23:45 usb-Generic_Flash_Disk_C173828A-0:0 -> ../../sdb lrwxrwxrwx 1 root root 10 ??? 18 23:45 usb-Generic_Flash_Disk_C173828A-0:0-part1 -> ../../sdb1 root@yurko-laptop:/home/yurko-laptop# dd if=/dev/zero of=/dev/sdb dd: ?????? ? «/dev/sdb»: ?? ?????????? ????????? ????? 8257537+0 ??????? ??????? 8257536+0 ??????? ???????? ??????????? 4227858432 ????? (4,2 GB), 942,633 c, 4,5 MB/c After that I wanted to create new filesystem using fdisk: root@yurko-laptop:/home/yurko-laptop# fdisk /dev/sdb You will not be able to write the partition table. WARNING: DOS-compatible mode is deprecated. It's strongly recommended to switch off the mode (command 'c') and change display units to sectors (command 'u'). Command (m for help): p Disk /dev/sdb: 4227 MB, 4227858432 bytes 4 heads, 63 sectors/track, 32768 cylinders Units = cylinders of 252 * 512 = 129024 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0x00000000 Device Boot Start End Blocks Id System /dev/sdb1 18 32768 4126596 b W95 FAT32 Command (m for help): fdisk showed that the partition still exists and I can't write the partition table. I tried to delete the existing partition: Command (m for help): d Selected partition 1 Command (m for help): w Unable to write /dev/sdb root@yurko-laptop:/home/yurko-laptop# Why am I not be able to write the partition table? Does it mean that some hardware failure occurred? And is it possible to repair the current USB drive? I've tried to use hdparm and it showed that the readonly flag is on: root@yurko-laptop:/home/yurko-laptop# hdparm /dev/sdb /dev/sdb: SG_IO: bad/missing sense data, sb[]: f0 00 05 00 00 00 00 0a 00 00 00 00 26 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 multcount = 0 (off) readonly = 1 (on) readahead = 256 (on) geometry = 1016/131/62, sectors = 8257536, start = 0

    Read the article

  • prevent filesystem from entering read-only mode

    - by user788171
    I have found that my server's filesystem is continuously entering read-only mode. There have been some issues with the raid1 array, but I have removed the bad disk from the array. However, it is still physically plugged into the system because I haven't had a chance to go over to the datacentre, I suspect udev and the system kernel is still picking up the bad disk and throwing errors. In /var/log/messages, there are errors like this: Mar 2 06:53:14 nocloud kernel: ata1: exception Emask 0x10 SAct 0x0 SErr 0x4010000 action 0xe frozen Mar 2 06:53:14 nocloud kernel: ata1: irq_stat 0x00400040, connection status changed Mar 2 06:53:14 nocloud kernel: ata1: SError: { PHYRdyChg DevExch } Mar 2 06:53:14 nocloud kernel: ata1: hard resetting link Mar 2 06:53:20 nocloud kernel: ata1: link is slow to respond, please be patient (ready=0) Mar 2 06:53:21 nocloud kernel: ata1: SATA link up 3.0 Gbps (SStatus 123 SControl 300) Mar 2 06:53:21 nocloud kernel: ata1.00: configured for UDMA/133 Mar 2 06:53:21 nocloud kernel: ata1: EH complete This happens fairly randomly throughout the day until eventually the filesystem becomes read-only. When this happens, my system becomes non-operational which kind of defeats the purpose of having a raid1. Note, ata1 is the bad disk (I think ata1 corresponds to /dev/sda because they are both first in line). Under mdadm, /dev/sda1,2 is no longer being used, but I can't prevent the system kernel from continuing to query that disk when I am no longer using it and throwing these errors. Is there a way to prevent my filesystem from automatically going into read-only mode? Furthermore, is it safe to do so? Thanks in advance. EDIT: Additional information: output from cat /proc/mdstat md1 : active raid1 sdb2[1] 976554876 blocks super 1.1 [2/1] [_U] bitmap: 5/8 pages [20KB], 65536KB chunk md0 : active raid1 sdb1[1] 204788 blocks super 1.0 [2/1] [_U] Output from mount: /dev/mapper/VolGroup-LogVol00 on / type ext4 (rw,noatime) proc on /proc type proc (rw) sysfs on /sys type sysfs (rw) devpts on /dev/pts type devpts (rw,gid=5,mode=620) tmpfs on /dev/shm type tmpfs (rw,rootcontext="system_u:object_r:tmpfs_t:s0") /dev/md0 on /boot type ext4 (rw) none on /proc/sys/fs/binfmt_misc type binfmt_misc (rw) sunrpc on /var/lib/nfs/rpc_pipefs type rpc_pipefs (rw) EDIT2: pvdisplay output: --- Physical volume --- PV Name /dev/md1 VG Name VolGroup PV Size 931.32 GiB / not usable 2.87 MiB Allocatable yes (but full) PE Size 16.00 MiB Total PE 59604 Free PE 0 Allocated PE 59604

    Read the article

  • Exchange 2007 Standard Edition

    - by Phrontiste
    We Have : Exchange 2007 Standard Edition IBM System X3650 2 x Intel Xeon 5430 2.66 GHz Version 8.1 Build 240.6 Mailbox, Hub Transport, Client Access Role Installed on One Box Total Number of Mailboxes : 110 - 130 6 Physical Disks Disk 0,1 (68 GB) = Raid-1, OS Partition ( C: Partition) Disk 2,3 (279GB) = Raid-1, Exchange Database (First and Second Storage Groups) ( D: Partition ) Disk 4,5 (68 GB) = Raid-1, Exchange Transaction Logs ( E: Partition ) Setup: Storage Groups : D:\First Storage group\Mailbox database.edb Storage Groups : D:\Second Storage Group\Public Folder Database.edb Transaction Logs : E Partition Problem 1: On our D Partition (Mailbox Database Partition), total size is 279 GB, free space remaining is 64.7 GB, when I select the first storage group and second storage group folders and right click properties they report a size of 165 GB. Mailbox database reports a size of 157GB when right clicked Properties. where as the size displayed in the folder is 164,893,456 KB So, we are missing around 50-54 GB, there is nothing else on these drives, no page file, nothing at all. The partition housing the Transaction logs is reporting the sizes accurately. Any suggestions / fixes on the above ? Problem 2: As you may have already read in Problem 1, the size of the mailbox database is 157GB or 164GB reported; which is not recommended, a) What would you suggest we should do to divide mailboxes in storage groups on this same server ? b) How would we move mailboxes into different storage groups ? c) This is the information store size ? (Am I right in thinking that this is not recommended) d) Having multiple storage groups with one Mailbox DB in each, would that reduce the size of the Information Store? e) Any suggestions / how-to reduce the size of information store ? We didn't install this, we have inherited this - what other recommendations you can make in order to keep ourselves better prepared for any server disaster? We are backing up with Yosemite Backup on RD1000 (320GB) at the moment, which is backing up successfully, flushing the logs daily. We haven't done a test restore YET. I have tried to provide as much info as possible, please let me know if you need further info. Also, we haven't yet faced any problems in mailflow, access speeds, everything is working fine, we have two to five people accessing OWA or Outlook via vpn only. Thanks for your time to read the above - will look forward to your expert suggestions.

    Read the article

  • Backing Up vs. Redundancy

    - by TK Kocheran
    I'm currently in stage 2 of 3 of building my home workstation. What this means is that my RAID-0 array of solid state disks will be backed up nightly to a RAID-5 or RAID-6 array of traditional spinning hard disks. However, it recently dawned on me that redundancy is not backup. The main reason for setting up a RAID array with redundancy was to protect myself in the event of a drive failure to serve as an effective backup solution. Wait. What if a bolt of lightning finds a way to travel into my house, through my surge-protector, into my power supply and physically destroys all of my hard disks and SSDs? Well, in that case, I guess I'd be fine because I generally keep most important files (music, pictures, videos) stored in multiple places like on my laptop, my wife's laptop, and an encrypted USB hard drive. Wait. What if a giant hedgehog meteor attacks my house from space traveling at mach 3 and all machines and hard disks are blown to smithereens. Well, I guess I could find a way to do ridiculously slow and cumbersome rsyncs or backups to Amazon's Glacier. Wait. What if there's a nuclear apocalypse... and at this point I start laughing hysterically. At what point does backing up become irrelevant? I completely understand situation one (mechanical drive failure), situation two (workstation compromised or destroyed somehow), possibly even situation three (all machines and disks destroyed), but situation four? There's no questioning the need for backups. None. However, there are three questions I'd really like addressed: To what level should one backup? I definitely understand the merits of physical disk redundancy. I also believe in keeping important files on multiple machines and thinning out the possibility of losing all of my files. Online backups make sense, but they beg the following question. What should I be backing up remotely and how often? It's no problem storage-wise to back up important files (music, pictures, videos) and even configuration and temporal data for all of the machines in my network (all Linux based)... albeit locally. Transferring to the cloud is another story. Worst-case scenario, if I lost all of my configuration for my individual computers, the reality is that I probably lost the machines too. The cloud is a long way away from here; I can run backups over CAT-6 here and see 100MB/s easily, but I'm afraid that I'm only going to see 2MB/s at best when transferring up to the cloud.

    Read the article

  • Easy Install Resets Hardware Settings

    - by bob5972
    I think there's a problem with the Easy Install setup. I selected "Installer disc image," and it came up and said that it would use "Easy Install," I think I hit next, and then I went back changed my mind, and selected "I will install the operating system later." After finishing the wizard, I think it still went and ran Easy Install, because it auto-installed VMware tools and I never got to select anything for my windows setup. Then, when it was finished, all the hardware changes I had made were lost. The RAM was changed from 2 GB back to the default of 1 GB, my CD ROM drive was set back to "Use a Physical Drive" and "Connect at Power On", and the Floppy Drive was also set to "Connect at Power On", after I disabled them. I was trying to install Windows 7, and I wasn't sure if I could change the RAM settings after installation without needing to reactivate it, so I deleted the VM and tried to start over. This time, the "Installer disc image" had my Win7 image pre-selected, so I clicked "I will install it myself later," set my hardware again, and tried to boot off my CD. Again,it did an Easy Install, and reset my RAM and my drive settings. So I deleted it again and the third time it still had the Win7 image pre-selected, but this time I unplugged all the drives and let it try to boot off the empty harddrive and fail, and made sure it kept all my hardware settings. Then, I powered it off, put my Win7 image in the guest CD ROM, and powered it on. This time it finally let me run the installer and pick my language, and type a user name. This time when I powered it off it kept my hardware settings. I can duplicate the error by doing exactly the steps above. Creating a new VM, selecting my "Installer Image," hitting next, going back, selecting "I will Install it myself," and then finish the wizard, and customizing my hardware right before the end, setting the CD Rom drive to the same installer media, and setting "Connect on Power On." (If I start it without the CD ROM in the first time, it doesn't do it). When I power on, I'm not prompted for any install information (like language and user name), and when it runs the first timemy hardware choices are reset (like the RAM back to 1 GB). If it helps, I'm running VMware Workstation 7.0.1 build-227600 on Gentoo Linux

    Read the article

  • Easy Install Resets Hardware Settings

    - by bob5972
    I think there's a problem with the Easy Install setup. I selected "Installer disc image," and it came up and said that it would use "Easy Install," I think I hit next, and then I went back changed my mind, and selected "I will install the operating system later." After finishing the wizard, I think it still went and ran Easy Install, because it auto-installed VMware tools and I never got to select anything for my windows setup. Then, when it was finished, all the hardware changes I had made were lost. The RAM was changed from 2 GB back to the default of 1 GB, my CD ROM drive was set back to "Use a Physical Drive" and "Connect at Power On", and the Floppy Drive was also set to "Connect at Power On", after I disabled them. I was trying to install Windows 7, and I wasn't sure if I could change the RAM settings after installation without needing to reactivate it, so I deleted the VM and tried to start over. This time, the "Installer disc image" had my Win7 image pre-selected, so I clicked "I will install it myself later," set my hardware again, and tried to boot off my CD. Again,it did an Easy Install, and reset my RAM and my drive settings. So I deleted it again and the third time it still had the Win7 image pre-selected, but this time I unplugged all the drives and let it try to boot off the empty harddrive and fail, and made sure it kept all my hardware settings. Then, I powered it off, put my Win7 image in the guest CD ROM, and powered it on. This time it finally let me run the installer and pick my language, and type a user name. This time when I powered it off it kept my hardware settings. I can duplicate the error by doing exactly the steps above. Creating a new VM, selecting my "Installer Image," hitting next, going back, selecting "I will Install it myself," and then finish the wizard, and customizing my hardware right before the end, setting the CD Rom drive to the same installer media, and setting "Connect on Power On." (If I start it without the CD ROM in the first time, it doesn't do it). When I power on, I'm not prompted for any install information (like language and user name), and when it runs the first timemy hardware choices are reset (like the RAM back to 1 GB). If it helps, I'm running VMware Workstation 7.0.1 build-227600 on Gentoo Linux

    Read the article

  • Windows Setup could not configure Windows to run on this computer's hardware

    - by Hello71
    The whole installation goes smoothly up to the point of "Completing installation ...". The monitor changes resolution, after which a standard dialog box pops up saying Windows Setup could not configure Windows to run on this computer's hardware Then, in a few seconds, the whole machine powers down. Trying to restart produces the message: STOP: c000021a {Fatal System Error} 0x00000000 (0xc0000001 0x00100448) OR it boots into Setup and comes up with the message: Windows Setup encountered an unexpected error... (This is not the actual error, just paraphrasing) I tried using the OEM restore instead of a regular install, but it fails with the same error. (Even though it worked before...) General specs: HP Pavilion Elite e9262f Intel Core i5-750 Processor ATI Radeon HD 4650 Hitachi HDT721010SLA360 ATA Device 6GB DDR3 RAM SuperMulti DVD Burner with LightScribe Some built-in Wi-Fi module http://h10025.www1.hp.com/ewfrf/wc/document?docname=c01916917 I've tried disconnecting the wireless card and disabling the built-in Ethernet and Firewire via the BIOS, and replacing the wireless keyboard and mouse with wired USB ones. Didn't work. I've also tried changing the SATA controller settings in the BIOS to RAID, AHCI, and IDE, reinstalling each time I changed. Still not working. I think the reason why it is showing the Fatal System Error is because it didn't finish installing before it errored out and shut down, so the system is left in an inconsistent state. I've tried 3 different copies (including the OEM restore) of Windows 7 now, and they're all failing at the same point, with the same error message. I've tried to install Windows 7 maybe 10 times already, with the exact same error message at the exact same location. Hm... Interestingly, the 32-bit version of Windows 7 works, but the 64-bit version doesn't. Perhaps it was a badly burned disk? Reburning the 64-bit version still comes up with the same error. Here's a picture of the side of the case that clearly says it came with Windows 7 64-bit, along with the model number and CPU. sudo fdisk -l: Disk /dev/sda: 1000.2 GB, 1000204886016 bytes 255 heads, 63 sectors/track, 121601 cylinders Units = cylinders of 16065 * 512 = 8225280 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0x0009896f Device Boot Start End Blocks Id System /dev/sda1 * 1 13 104391 7 HPFS/NTFS /dev/sda2 14 94119 755906445 7 HPFS/NTFS /dev/sda3 119922 121602 13492224 7 HPFS/NTFS /dev/sda4 94120 119922 207257740+ 5 Extended /dev/sda5 119527 119922 3170769 82 Linux swap / Solaris /dev/sda6 107174 119526 99225441 83 Linux /dev/sda7 94120 107173 104856192 7 HPFS/NTFS Partition table entries are not in disk order

    Read the article

  • Varnish 503 Guru Mediation errors with pfsense and healthy apache

    - by Fammy
    We are running a pfsense firewall / load balancer with varnish as service, In front of Fedora linux webservers running apache. We are getting intermittent 503 guru mediation errors. We are a bit stuck scratching our heads because it is not easily repeatable. The timeouts are set to 30s (connect and first byte) but yet the 503 page will show instantly, not after 30s. Then if you refresh immediately it may very well work instantly and sometimes for a 100 refreshes. The load average on the web servers is < 1, the DB server is < 3 (all servers (web, db, pfsense/varnish) are physical rather than VM. I would have thought if the timeouts were being hit then the 503 page would only appear after 30s am I mistaken? Also when an error happens there does not appear to be any corresponding error in apache's log files. This seems to affect pages as well as images, so it is possible to have the page load fine, and for 9/10 images on the page to be fine but 1 not work An example of the varnish debug is below. It says no backend connection but I can't figure out why, if the load was high on apache I could understand it being flaky The machines are on the same gig ethernet lan 21 ReqStart c *IP-REMOVED* 33418 1274368062 21 RxRequest c GET 21 RxURL c /fashion/ 21 RxProtocol c HTTP/1.1 21 RxHeader c User-Agent: Mozilla/5.0 (X11; U; Linux x86_64; en-US; rv:1.9.0.5) Gecko/2008121622 Fedora/3.0.5-1.fc10 Firefox/3.0.5 21 RxHeader c Host: *ourdomain.com* 21 RxHeader c Accept: */* 21 RxHeader c Accept-Encoding: deflate, gzip 21 VCL_call c recv lookup 21 VCL_call c hash 21 Hash c /fashion/ 21 Hash c *ourdomain.com* 21 VCL_return c hash 21 VCL_call c miss fetch 21 FetchError c no backend connection 21 VCL_call c error restart 21 VCL_call c recv lookup 21 VCL_call c hash 21 Hash c /fashion/ 21 Hash c *ourdomain.com* 21 VCL_return c hash 21 VCL_call c miss fetch 21 FetchError c no backend connection 21 VCL_call c error restart 21 VCL_call c recv lookup 21 VCL_call c hash 21 Hash c /fashion/ 21 Hash c *ourdomain.com* 21 VCL_return c hash 21 VCL_call c miss fetch 21 FetchError c no backend connection 21 VCL_call c error deliver 21 VCL_call c deliver deliver 21 TxProtocol c HTTP/1.1 21 TxStatus c 503 21 TxResponse c Service Unavailable 21 TxHeader c Server: Varnish 21 TxHeader c Content-Type: text/html; charset=utf-8 21 TxHeader c Content-Length: 384 21 TxHeader c Accept-Ranges: bytes 21 TxHeader c Date: Wed, 11 Apr 2012 10:36:17 GMT 21 TxHeader c X-Varnish: 1274368062 21 TxHeader c Age: 0 21 TxHeader c Via: 1.1 varnish 21 TxHeader c Connection: close 21 TxHeader c X-Cache: MISS 21 Length c 384 21 ReqEnd c 1274368062 1334140577.449995041 1334140577.450334787 1.794108152 0.000282764 0.000056982

    Read the article

< Previous Page | 119 120 121 122 123 124 125 126 127 128 129 130  | Next Page >