Search Results

Search found 2093 results on 84 pages for 'logical'.

Page 18/84 | < Previous Page | 14 15 16 17 18 19 20 21 22 23 24 25  | Next Page >

  • HP Smart Array; Is it possible to convert Raid1 to Raid0 by dropping a failed drive?

    - by Erik Heppler
    I have a server that was running two 60GB drives as a logical RAID1. At some point the second drive was physically removed and the logical drive has been in "Interim Recovery Mode" for several months now. There's no need for the redundancy of RAID1 on this machine, and I have no intention of replacing the missing drive. If possible I would like to convert the current RAID1 to a single-drive RAID0 by simply dropping the failed drive from the current configuration. I'm only interested in doing this if it can be done in-place. Otherwise I'm perfectly content to leave it in "Interim Recovery Mode" indefinitely.

    Read the article

  • CentOS - Add additional hard drive raid arrays on Dell Perc 5/i card

    - by Quanano
    We have a Dell Poweredge 2900 system with Dell Perc 5/i card and 4 SAS hard drives attached, with NTFS partitions on them. We installed CentOS on one raid array on this controller with a different controller and it is working fine. We are now trying to access the drives shown above and they are not being shown in /dev as sdb, etc. sda is the drive that we installed centos on and it has sda1, sda2, sda3, etc. The CDROM has been picked up as well. If I scan for scsi devices then the perc and adaptec controllers are both found. sg0 is the CDROM and sg2 is the centos installed, however I think sg1 is the other drive but I cannot see anyway to mount the partitions, as only the drive is listed in /dev. Thanks. EXTRA INFO fdisk -l: Disk /dev/sda: 72.7 GB, 72746008576 bytes 255 heads, 63 sectors/track, 8844 cylinders Units = cylinders of 16065 * 512 = 8225280 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0x11e3119f Device Boot Start End Blocks Id System /dev/sda1 * 1 64 512000 83 Linux Partition 1 does not end on cylinder boundary. /dev/sda2 64 8845 70528000 8e Linux LVM Disk /dev/mapper/vg_lal2server-lv_root: 34.4 GB, 34431041536 bytes 255 heads, 63 sectors/track, 4186 cylinders Units = cylinders of 16065 * 512 = 8225280 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0x00000000 Disk /dev/mapper/vg_lal2server-lv_root doesn't contain a valid partition table Disk /dev/mapper/vg_lal2server-lv_swap: 21.1 GB, 21139292160 bytes 255 heads, 63 sectors/track, 2570 cylinders Units = cylinders of 16065 * 512 = 8225280 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0x00000000 Disk /dev/mapper/vg_lal2server-lv_swap doesn't contain a valid partition table Disk /dev/mapper/vg_lal2server-lv_home: 16.6 GB, 16647192576 bytes 255 heads, 63 sectors/track, 2023 cylinders Units = cylinders of 16065 * 512 = 8225280 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0x00000000 Disk /dev/mapper/vg_lal2server-lv_home doesn't contain a valid partition table These are all from the install hdd not the additional hard drives modprobe a320raid FATAL: Module a320raid not found. lsscsi -v: [0:0:0:0] cd/dvd TSSTcorp CDRWDVD TS-H492C DE02 /dev/sr0 dir: /sys/bus/scsi/devices/0:0:0:0 [/sys/devices/pci0000:00/0000:00:1f.1/host0/target0:0:0/0:0:0:0] [4:0:10:0] enclosu DP BACKPLANE 1.05 - dir: /sys/bus/scsi/devices/4:0:10:0 [/sys/devices/pci0000:00/0000:00:05.0/0000:01:00.0/0000:02:0e.0/host4/target4:0:10/4:0:10:0] [4:2:0:0] disk DELL PERC 5/i 1.03 /dev/sda dir: /sys/bus/scsi/devices/4:2:0:0 [/sys/devices/pci0000:00/0000:00:05.0/0000:01:00.0/0000:02:0e.0/host4/target4:2:0/4:2:0:0] . lsmod: Module Size Used by fuse 66285 0 des_generic 16604 0 ecb 2209 0 md4 3461 0 nls_utf8 1455 0 cifs 278370 0 autofs4 26888 4 ipt_REJECT 2383 0 ip6t_REJECT 4628 2 nf_conntrack_ipv6 8748 2 nf_defrag_ipv6 12182 1 nf_conntrack_ipv6 xt_state 1492 2 nf_conntrack 79453 2 nf_conntrack_ipv6,xt_state ip6table_filter 2889 1 ip6_tables 19458 1 ip6table_filter ipv6 322029 31 ip6t_REJECT,nf_conntrack_ipv6,nf_defrag_ipv6 bnx2 79618 0 ses 6859 0 enclosure 8395 1 ses dcdbas 9219 0 serio_raw 4818 0 sg 30124 0 iTCO_wdt 13662 0 iTCO_vendor_support 3088 1 iTCO_wdt i5000_edac 8867 0 edac_core 46773 3 i5000_edac i5k_amb 5105 0 shpchp 33482 0 ext4 364410 3 mbcache 8144 1 ext4 jbd2 88738 1 ext4 sd_mod 39488 3 crc_t10dif 1541 1 sd_mod sr_mod 16228 0 cdrom 39771 1 sr_mod megaraid_sas 77090 2 aic79xx 129492 0 scsi_transport_spi 26151 1 aic79xx pata_acpi 3701 0 ata_generic 3837 0 ata_piix 22846 0 radeon 1023359 1 ttm 70328 1 radeon drm_kms_helper 33236 1 radeon drm 230675 3 radeon,ttm,drm_kms_helper i2c_algo_bit 5762 1 radeon i2c_core 31276 4 radeon,drm_kms_helper,drm,i2c_algo_bit dm_mirror 14101 0 dm_region_hash 12170 1 dm_mirror dm_log 10122 2 dm_mirror,dm_region_hash dm_mod 81500 11 dm_mirror,dm_log blkid: /dev/sda1: UUID="bc4777d9-ae2c-4c58-96ea-cedb342b8338" TYPE="ext4" /dev/sda2: UUID="j2wRZr-Mlko-QWBR-BndC-V2uN-vdhO-iKCuYu" TYPE="LVM2_member" /dev/mapper/vg_lal2server-lv_root: UUID="9238208a-1daf-4c3c-aa9b-469f0387ebee" TYPE="ext4" /dev/mapper/vg_lal2server-lv_swap: UUID="dbefb39c-5871-4bc9-b767-1ef18f12bd3d" TYPE="swap" /dev/mapper/vg_lal2server-lv_home: UUID="ec698993-08b7-443e-84f0-9f9cb31c5da8" TYPE="ext4" dmesg shows: megaraid_sas: fw state:c0000000 megasas: fwstate:c0000000, dis_OCR=0 scsi2 : LSI SAS based MegaRAID driver scsi 2:0:0:0: Direct-Access SEAGATE ST3146855SS S527 PQ: 0 ANSI: 5 scsi 2:0:1:0: Direct-Access SEAGATE ST3146855SS S527 PQ: 0 ANSI: 5 scsi 2:0:2:0: Direct-Access SEAGATE ST3146855SS S527 PQ: 0 ANSI: 5 scsi 2:0:3:0: Direct-Access SEAGATE ST3146855SS S527 PQ: 0 ANSI: 5 scsi 2:0:4:0: Direct-Access HITACHI HUS154545VLS300 D590 PQ: 0 ANSI: 5 scsi 2:0:5:0: Direct-Access HITACHI HUS154545VLS300 D590 PQ: 0 ANSI: 5 scsi 2:0:8:0: Direct-Access FUJITSU MBA3073RC D305 PQ: 0 ANSI: 5 scsi 2:0:9:0: Direct-Access FUJITSU MBA3073RC D305 PQ: 0 ANSI: 5 i.e. the 3 RAID Arrays Seagate Hitatchi and Fujitsu hard drives respectively. FURTHER UPDATE I have installed the megaraid storage manager console and connected to the server. It appears that the two CentOS installation hard drives are OK. The other 6 drives, one raid array of 4 and one raid array of 2 disks. The other drives are listed as (Foreign) Unconfigured Good.

    Read the article

  • Why is my USB-to-VGA'd monitor working, but not showing in Display Settings?

    - by Strilanc
    I have a USB-to-VGA adapter, which I use to connect a second monitor to my laptop (totaling 3 screens). It worked alright with Vista. I upgraded to Windows 7, and now it no longer works properly (I downloaded the latest drivers just to get it to work on 7). The extra monitor is detected and used to extend the desktop (I can move things onto it, etc), but is not shown within the Control Panel. This is annoying because now I can't changes its resolution, set its logical position to match its physical position, etc. Can I do anything, besides waiting for better drivers? I'm mainly concerned with moving its logical position. (I'd also like to understand how Windows can use a monitor it can't detect. Weird.)

    Read the article

  • Cannot install grub to RAID1 (md0)

    - by Andrew Answer
    I have a RAID1 array on my Ubuntu 12.04 LTS and my /sda HDD has been replaced several days ago. I use this commands to replace: # go to superuser sudo bash # see RAID state mdadm -Q -D /dev/md0 # State should be "clean, degraded" # remove broken disk from RAID mdadm /dev/md0 --fail /dev/sda1 mdadm /dev/md0 --remove /dev/sda1 # see partitions fdisk -l # shutdown computer shutdown now # physically replace old disk by new # start system again # see partitions fdisk -l # copy partitions from sdb to sda sfdisk -d /dev/sdb | sfdisk /dev/sda # recreate id for sda sfdisk --change-id /dev/sda 1 fd # add sda1 to RAID mdadm /dev/md0 --add /dev/sda1 # see RAID state mdadm -Q -D /dev/md0 # State should be "clean, degraded, recovering" # to see status you can use cat /proc/mdstat This is the my mdadm output after sync: /dev/md0: Version : 0.90 Creation Time : Wed Feb 17 16:18:25 2010 Raid Level : raid1 Array Size : 470455360 (448.66 GiB 481.75 GB) Used Dev Size : 470455360 (448.66 GiB 481.75 GB) Raid Devices : 2 Total Devices : 2 Preferred Minor : 0 Persistence : Superblock is persistent Update Time : Thu Nov 1 15:19:31 2012 State : clean Active Devices : 2 Working Devices : 2 Failed Devices : 0 Spare Devices : 0 UUID : 92e6ff4e:ed3ab4bf:fee5eb6c:d9b9cb11 Events : 0.11049560 Number Major Minor RaidDevice State 0 8 1 0 active sync /dev/sda1 1 8 17 1 active sync /dev/sdb1 After bebuilding completion "fdisk -l" says what I have not valid partition table /dev/md0. This is my fdisk -l output: Disk /dev/sda: 500.1 GB, 500107862016 bytes 255 heads, 63 sectors/track, 60801 cylinders, total 976773168 sectors Units = sectors of 1 * 512 = 512 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0x00057d19 Device Boot Start End Blocks Id System /dev/sda1 * 63 940910984 470455461 fd Linux raid autodetect /dev/sda2 940910985 976768064 17928540 5 Extended /dev/sda5 940911048 976768064 17928508+ 82 Linux swap / Solaris Disk /dev/sdb: 500.1 GB, 500107862016 bytes 255 heads, 63 sectors/track, 60801 cylinders, total 976773168 sectors Units = sectors of 1 * 512 = 512 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0x000667ca Device Boot Start End Blocks Id System /dev/sdb1 * 63 940910984 470455461 fd Linux raid autodetect /dev/sdb2 940910985 976768064 17928540 5 Extended /dev/sdb5 940911048 976768064 17928508+ 82 Linux swap / Solaris Disk /dev/md0: 481.7 GB, 481746288640 bytes 2 heads, 4 sectors/track, 117613840 cylinders, total 940910720 sectors Units = sectors of 1 * 512 = 512 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0x00000000 Disk /dev/md0 doesn't contain a valid partition table This is my grub install output: root@answe:~# grub-install /dev/sda /usr/sbin/grub-setup: warn: Attempting to install GRUB to a disk with multiple partition labels or both partition label and filesystem. This is not supported yet.. /usr/sbin/grub-setup: error: embedding is not possible, but this is required for cross-disk install. root@answe:~# grub-install /dev/sdb Installation finished. No error reported. So 1) "update-grub" find only /sda and /sdb Linux, not /md0 2) "dpkg-reconfigure grub-pc" says "GRUB failed to install the following devices /dev/md0" I cannot load my system except from /sdb1 and /sda1, but in DEGRADED mode... Anybody can resolve this issue? I have big headache with this.

    Read the article

  • WBAdmin SystemState Problems

    - by TheD
    I recently installed DHCP on my 2008R2 Server and now Backup Exec and WBAdmin/WSB is having System State issues. Essentially, after some research, I came across a handy tool called VSHADOW which has allowed me to output all the files (and their respective directories) to a text file. And hooray, I think I found the problem: * WRITER "Dhcp Jet Writer" - WriterId = {be9ac81e-3619-421f-920f-4c6fea9e93ad} - InstanceId = {0ed0a8f4-19b0-414d-a3a8-d51d6f4ac8e0} - Supports restore events = TRUE - Writer restore conditions = VSS_WRE_IF_REPLACE_FAILS - Restore method = VSS_RME_RESTORE_AT_REBOOT - Requires reboot after restore = TRUE - Excluded files: - Component "Dhcp Jet Writer:\C:_Windows_system32_dhcp\dhcp" - Name: 'dhcp' - Logical Path: 'C:_Windows_system32_dhcp' - Full Path: '\C:_Windows_system32_dhcp\dhcp' The logical path and Full Path for DHCP is completely wrong. However I can't find where I would change this path, I assume in the registry but I've had no luck finding the key !

    Read the article

  • Parity Initialization after putting in two new disks

    - by lbanz
    All my firmware is up to date on the server and the controllers. Storage crashed over the weekend. I rebooted it and it detected that I put in two new disks last week (I did check that both disk completed the rebuilding process last week). After it booted into the OS I see that it gave me an information message. After 18 hours it is at 54% so it is looking healthy. But I need to replace 5 more disk in the msa. Should I wait for this message to finish before replacing more disks? 785 Background parity initialization is currently queued or in progress on Logical Drive 1 (15.0 TB, RAID 5). If background parity initialization is queued, it will start when I/O is performed on the drive. When background parity initialization completes, the performance of the logical drive will improve.

    Read the article

  • PostgreSQL RAID configuration

    - by Yoldar-Zi
    I'm stuck how best to configure disk array. We have Hp P2000 G3 disk array with 24 SAS physical disks 300Gb each. We need to configure this array got 2 copies of PostgreSQL 9.2 because two different system. As we know it's recommended to store database and transaction logs(pg_xlog) files on separate disks. So we must setup 4 logical disk: 2 for transaction logs with RAID 1 2 for database with RAID 10 Is this right scheme of distribution? Or may be it is best to just make one big RAID 10 with 4 logical disks?

    Read the article

  • How anti-virus on the host machne affects performance of virtual machines?

    - by Ladislav Mrnka
    I'm diagnosing some issue with Oracle virtual box where virtual machine sometimes perform terribly slow (much slower then notebook with worse configuration): Notebook i7 (2 cores with HT = 4 logical CPUs), 4GB RAM, 5400 rpm disk, Win 7 64bit Virtual machine (Oracle Virtual Box) Host: i7 (4 cores with HT = 8 logical CPUs, 12 GB RAM, system runs from SSD, virtual machine from 7200 rpm disk, Win 7 64bit) Virtual machine: 4 cores assigned, 8 GB RAM assigned, Win 2008 R2 Enterprise (64 bit) Virtual machine uses bridge to separate network interface (machine has two) VPN for network communication No other virtual machine runs on the host Host has installed ESET Smart Security All SW is updated with last version. My question is if anti-virus on the host machine can somehow affect performance of the virtual machine and if so how can I turn it off without turning the anti-virus itself?

    Read the article

  • Help me understand how Xen vCPU/CPU works

    - by luckytaxi
    Say I have a Dual-Core server, that's 4 cores w/ two physical processors. I read numerous articles that states the dom0 should get one physical core to itself. By core, does that mean a single CPU core or one of the 4 logical cores? Ideally I would like to dedicate a single CPU core (2 logical) to the dom0. Then I would give the other CPU split between the 3 VMs. I've seen examples where ppl would assign more than the available number of cores to a VM and I don't know what good that would do. I mean, why would I want to assign 4 vCPU to a single VM when I only have 2 available (if my math is correct)? I assume I only have 2 available from the one core as I've given dom0 a CPU to itself.

    Read the article

  • Lost Page Write I/O Errors on CentOS LVM setup

    - by Gregg Leventhal
    I have a CentOS 6 box with LVM setup and one of the PVs is a USB disk (I know). One of them is getting the error: Oct 30 10:57:07 alpha01 kernel: lost page write due to I/O error on dm-3 Oct 30 10:57:07 alpha01 kernel: Buffer I/O error on device dm-3, logical block 4 Which is causing problems with all of the LVs on it. pvs shows the PV as unknown device. I can ls to the logical volumes and they show up in lvdisplay, but first I get a bunch of IO errors. I made sure the cables are secure between the USB drive. What should I do to get this back up and running for the meanwhile? Should I unmount each LV and run an fsck.ext4 on each one like fsck.ext4 -y /dev/vg1/lv_logvolname ?

    Read the article

  • Kickstart Partitioning Configuration

    - by Flo
    I'be been trying to run a kickstart script with the following partition configuration: #Clear the masterboot record zerombr bootloader --location=mbr --driveorder=sda --append=" rhgb crashkernel=auto quiet" # Set up the partitions/logical volumes/logical groups clearpart --all part /boot --fstype=ext4 --asprimary --size=512 --ondisk=sda part swap --size=2048 --fstype=swap --ondisk=sda part pv.01 --fstype=ext4 --grow --size=200 --ondisk=sda part pv.02 --fstype=ext4 --grow --size=200 --ondisk=sdb volgroup VolGroup pv.01 pv.02 --pesize=32768 logvol /opt --fstype=ext4 --name=opt.fs --vgname=VolGroup --size=40000 logvol / --fstype=ext4 --name=root.fs --vgname=VolGroup --size=78000 I have two hard drives and it looks to me like its a really simple configuration. When I run the kickstart I keep getting all these errors that have to do with python files for configuring partitions. The only actual maybe useful piece of information is KeyError /dev/sda/ I tried a number of alterations of this configuration but nothing really worked. Any ideas?

    Read the article

  • What is Paging in memory management?

    - by Fasih Khatib
    I was just reading Operating System Principles by Silberschatz et al when I came across paging in memory management.I'm slightly confused about it. It states that Physical Memory(I assume it's RAM) is divided into frames, and logical memory is divided into pages. CPU generates logical addresses containing page number and an offset. This page number is used to retrieve the frame number from a page table which gives the base address so the physical address is calculated as base+offset. My question is: is the page table maintained for every process? I logically think that the answer would be yes as every process will need to map its own pages to frames. I may be wrong. Please clarify. Also: paging and segmentation(where 'holes' are created in memory) are two totally different techniques that are not used in combination. Correct?

    Read the article

  • Partition and mount my secondary hard drive on CentOS 5.5 64bit?

    - by Andrew Fashion
    I am trying to prepare my second hard drive for user image uploads. Here is the current layout: # sudo parted /dev/sda print Model: ATA WDC WD2500KS-00M (scsi) Disk /dev/sda: 250GB Sector size (logical/physical): 512B/512B Partition Table: msdos Number Start End Size Type File system Flags 1 32.3kB 107MB 107MB primary ext3 boot 2 107MB 8595MB 8488MB primary linux-swap 3 8595MB 10.7GB 2147MB primary ext3 4 10.7GB 250GB 239GB extended 5 10.7GB 250GB 239GB logical ext3 Information: Don't forget to update /etc/fstab, if necessary. I am assuming #4 is my secondary drive? How do I partition and mount it so I can begin using it? And how do I add to fstab? I understand if it's to many questions in one, just help me with whatever you can I guess :) Thank you for any help!

    Read the article

  • Do I need to reserve space before installing Ubuntu alongside Windows 7?

    - by CRM Junkie
    I had Windows 7 32 bit on my existing system, but I am planning to install Ubuntu alongside it. So, I just decided to do a fresh installation of both the operating systems. When I insert the Windows 7 DVD, I can create 3 partitions at maximum, with one being the one where Windows 7 will be installed. I just wanted to know – do I need to keep some un-partitioned space for Ubuntu to install? By "unpartitioned space" I mean the space left after creating 3 partitions for Windows 7. I have a 500 GB HDD, so the three partitions I would be creating are 120 GB, 120 GB and 120 GB. The rest is shown as some logical drive, is that unpartitioned space? Can I install Ubuntu over there? I am pretty sure the space shown as logical won't be available as drives when I log into Windows 7. Is that space lost or can I use that to install ubuntu?

    Read the article

  • Can I lvreduce after lvextend without losing the ext4 partition inside it?

    - by DrSAR
    In a botched attempt to move my root partition from one disk to another I have done the following: added new disk partitioned it with parted (part #3 is now almost totally filling the disk) initialized a physical volume $ pvcreate /dev/sdb3 Physical volume "/dev/sdb3" successfully created extended the volume group to include this new physical disk $ vgextend myvg /dev/sdb3 Volume group "myvg" successfully extended extended the logical volume (I think this is where I ballsed it up: I think I should have pvmove'ed stuff to the new pv in that group - can someone confirm?) $ lvextend /dev/mapper/myvg-root /dev/sdb3 I would now like to undo the lvextend and then proceed with the original plan of moving the content of the old physical volume over to the new physical volume. Can I reduce the logical volume (I have not yet touched the ext4 partition that sits in /dev/mapper/myvg-root with something like resizefs) without fear of damaging the ext4 filesystem? If so, how do I tell it to reduce by exactly the right amount? $ lvreduce --by-exactly-the-amount-occupied-by-PV /ev/sdb3 /dev/mapper/myvg-root

    Read the article

  • RAID striping on a desktop machine

    - by Blazemore
    I currently have a 120Gib SSD which is pretty fast for things like game loading times and video editing. However, I was wondering about getting another identical drive and hooking it up with a striping RAID array in hardware (I boot multiple operating systems). This would have the dual benefits of providing a larger logical drive, while also providing greater performance. However, I have a few questions: What kind of performance increase can I expect to see with a pair of good quality SSDs? How expensive is a quality desktop RAID controller? Will the controller present the OS with a single logical drive? Does this mean I can still partition it and multi-boot? Basically, can I treat the RAID controller as "a hard drive" at the OS level?

    Read the article

  • How do I install a driver for an Atheros AR9285?

    - by Fernando
    How to install the driver for Atheros AR9285 in Ubuntu 11.10. Still no package for 11.10 according to this https://help.ubuntu.com/community/WifiDocs/Device/Atheros/AR9285 Here is the output of the commands marc@fer-VPCYA1V9E:~$ sudo lshw -class network *-network DISABLED description: Wireless interface product: AR9285 Wireless Network Adapter (PCI-Express) vendor: Atheros Communications Inc. physical id: 0 bus info: pci@0000:02:00.0 logical name: wlan0 version: 01 serial: 4c:0f:6e:d6:65:cc width: 64 bits clock: 33MHz capabilities: pm msi pciexpress bus_master cap_list ethernet physical wireless configuration: broadcast=yes driver=ath9k driverversion=3.0.0-12-generic firmware=N/A latency=0 link=no multicast=yes wireless=IEEE 802.11bgn resources: irq:16 memory:d3400000-d340ffff *-network description: Ethernet interface product: AR8131 Gigabit Ethernet vendor: Atheros Communications physical id: 0 bus info: pci@0000:03:00.0 logical name: eth0 version: c0 serial: 54:42:49:a2:1f:bc capacity: 1Gbit/s width: 64 bits clock: 33MHz capabilities: pm msi pciexpress vpd bus_master cap_list ethernet physical tp 10bt 10bt-fd 100bt 100bt-fd 1000bt-fd autonegotiation configuration: autonegotiation=on broadcast=yes driver=atl1c driverversion=1.0.1.0-NAPI firmware=N/A latency=0 link=no multicast=yes port=twisted pair resources: irq:43 memory:d2400000-d243ffff ioport:1000(size=128) And the second command marc@fer-VPCYA1V9E:~$ rfkill list 0: sony-wifi: Wireless LAN Soft blocked: no Hard blocked: no 1: sony-bluetooth: Bluetooth Soft blocked: no Hard blocked: no 2: phy0: Wireless LAN Soft blocked: no Hard blocked: no 3: hci0: Bluetooth Soft blocked: no Hard blocked: no 4: acer-wireless: Wireless LAN Soft blocked: yes Hard blocked: no Is there a way to make it work?

    Read the article

  • How do I connect my NetXtreme BCM5755M Gigabit Ethernet PCI Express in y Dell latitude d630?

    - by Stanton.Sculpture
    Trying to get my 09:00.0 Ethernet controller: Broadcom Corporation NetXtreme BCM5755M Gigabit Ethernet PCI Express (rev 02) working with my wifi. I just installed Raring Ringtail on this dell latitude D630 and I can't get it to connect without a wifi dongle. This is what I got when I typed sudo lshw -c network: *-network description: Ethernet interface product: NetXtreme BCM5755M Gigabit Ethernet PCI Express vendor: Broadcom Corporation physical id: 0 bus info: pci@0000:09:00.0 logical name: eth0 version: 02 serial: 00:21:70:98:04:32 capacity: 1Gbit/s width: 64 bits clock: 33MHz capabilities: pm vpd msi pciexpress bus_master cap_list ethernet physical tp 10bt 10bt-fd 100bt 100bt-fd 1000bt 1000bt-fd autonegotiation configuration: autonegotiation=on broadcast=yes driver=tg3 driverversion=3.128 firmware=5755m-v3.29 latency=0 link=no multicast=yes port=twisted pair resources: irq:44 memory:fe8f0000-fe8fffff *-network description: Wireless interface physical id: 2 bus info: usb@2:1 logical name: wlan0 serial: 7c:dd:90:11:a0:10 capabilities: ethernet physical wireless configuration: broadcast=yes driver=rt2800usb driverversion=3.8.0-31-generic firmware=0.29 ip=10.0.0.8 link=yes multicast=yes wireless=IEEE 802.11bgn Also, when I go to additional drivers in the software and updates settings, no proprietary drivers show up. I've tried sudo apt-get install b43-fwcutter firmware-b43-installer because it worked on a bunch of old Dell laptops that I converted over before, but it didn't work on this one. Is this driver even compatible with wifi? Please help.

    Read the article

  • SQLAuthority News – Whitepaper – SQL Azure vs. SQL Server

    - by pinaldave
    SQL Server and SQL Azure are two Microsoft Products which goes almost together. There are plenty of misconceptions about SQL Azure. I have seen enough developers not planning for SQL Azure because they are not sure what exactly they are getting into. Some are confused thinking Azure is not powerful enough. I disagree and strongly urge all of you to read following white paper written and published by Microsoft. SQL Azure vs. SQL Server by Dinakar Nethi, Niraj Nagrani SQL Azure Database is a cloud-based relational database service from Microsoft. SQL Azure provides relational database functionality as a utility service. Cloud-based database solutions such as SQL Azure can provide many benefits, including rapid provisioning, cost-effective scalability, high availability, and reduced management overhead. This paper compares SQL Azure Database with SQL Server in terms of logical administration vs. physical administration, provisioning, Transact-SQL support, data storage, SSIS, along with other features and capabilities. The content of this white paper is as following: Similarities and Differences Logical Administration vs. Physical Administration Provisioning Transact-SQL Support Features and Types Key Benefits of the Service Self-Managing High Availability Scalability Familiar Development Model Relational Data Model The above summary text is taken from white paper itself. Reference: Pinal Dave (http://blog.sqlauthority.com) Filed under: SQL, SQL Authority, SQL Query, SQL Server, SQL Tips and Tricks, SQL White Papers, SQLAuthority News, T SQL, Technology Tagged: SQL Azure

    Read the article

  • SQLAuthority News – Download Whitepaper – Understanding and Controlling Parallel Query Processing in SQL Server

    - by pinaldave
    My recently article SQL SERVER – Reducing CXPACKET Wait Stats for High Transactional Database has received many good comments regarding MAXDOP 1 and MAXDOP 0. I really enjoyed reading the comments as the comments are received from industry leaders and gurus. I was further researching on the subject and I end up on following white paper written by Microsoft. Understanding and Controlling Parallel Query Processing in SQL Server Data warehousing and general reporting applications tend to be CPU intensive because they need to read and process a large number of rows. To facilitate quick data processing for queries that touch a large amount of data, Microsoft SQL Server exploits the power of multiple logical processors to provide parallel query processing operations such as parallel scans. Through extensive testing, we have learned that, for most large queries that are executed in a parallel fashion, SQL Server can deliver linear or nearly linear response time speedup as the number of logical processors increases. However, some queries in high parallelism scenarios perform suboptimally. There are also some parallelism issues that can occur in a multi-user parallel query workload. This white paper describes parallel performance problems you might encounter when you run such queries and workloads, and it explains why these issues occur. In addition, it presents how data warehouse developers can detect these issues, and how they can work around them or mitigate them. To review the document, please download the Understanding and Controlling Parallel Query Processing in SQL Server Word document. Note: Above abstract has been taken from here. The real question is what does the parallel queries has made life of DBA much simpler or is it looked at with potential issue related to degradation of the performance? Reference: Pinal Dave (http://blog.sqlauthority.com) Filed under: SQL, SQL Authority, SQL Query, SQL Server, SQL Tips and Tricks, SQL White Papers, SQLAuthority News, T SQL, Technology

    Read the article

  • SQL SERVER – Find Most Expensive Queries Using DMV

    - by pinaldave
    The title of this post is what I can express here for this quick blog post. I was asked in recent query tuning consultation project, if I can share my script which I use to figure out which is the most expensive queries are running on SQL Server. This script is very basic and very simple, there are many different versions are available online. This basic script does do the job which I expect to do – find out the most expensive queries on SQL Server Box. SELECT TOP 10 SUBSTRING(qt.TEXT, (qs.statement_start_offset/2)+1, ((CASE qs.statement_end_offset WHEN -1 THEN DATALENGTH(qt.TEXT) ELSE qs.statement_end_offset END - qs.statement_start_offset)/2)+1), qs.execution_count, qs.total_logical_reads, qs.last_logical_reads, qs.total_logical_writes, qs.last_logical_writes, qs.total_worker_time, qs.last_worker_time, qs.total_elapsed_time/1000000 total_elapsed_time_in_S, qs.last_elapsed_time/1000000 last_elapsed_time_in_S, qs.last_execution_time, qp.query_plan FROM sys.dm_exec_query_stats qs CROSS APPLY sys.dm_exec_sql_text(qs.sql_handle) qt CROSS APPLY sys.dm_exec_query_plan(qs.plan_handle) qp ORDER BY qs.total_logical_reads DESC -- logical reads -- ORDER BY qs.total_logical_writes DESC -- logical writes -- ORDER BY qs.total_worker_time DESC -- CPU time You can change the ORDER BY clause to order this table with different parameters. I invite my reader to share their scripts. Reference: Pinal Dave (http://blog.SQLAuthority.com) Filed under: Pinal Dave, SQL, SQL Authority, SQL Optimization, SQL Performance, SQL Query, SQL Scripts, SQL Server, SQL Tips and Tricks, SQLAuthority News, SQLServer, T SQL, Technology Tagged: SQL DMV

    Read the article

  • Best Practices - updated: which domain types should be used to run applications

    - by jsavit
    This post is one of a series of "best practices" notes for Oracle VM Server for SPARC (formerly named Logical Domains). This is an updated and enlarged version of the post on this topic originally posted October 2012. One frequent question "what type of domain should I use to run applications?" There used to be a simple answer: "run applications in guest domains in almost all cases", but now there are more things to consider. Enhancements to Oracle VM Server for SPARC and introduction of systems like the current SPARC servers including the T4 and T5 systems, the Oracle SuperCluster T5-8 and Oracle SuperCluster M6-32 provide scale and performance much higher than the original servers that ran domains. Single-CPU performance, I/O capacity, memory sizes, are much larger now, and far more demanding applications are now being hosted in logical domains. The general advice continues to be "use guest domains in almost all cases", meaning, "use virtual I/O rather than physical I/O", unless there is a specific reason to use the other domain types. The sections below will discuss the criteria for choosing between domain types. Review: division of labor and types of domain Oracle VM Server for SPARC offloads management and I/O functionality from the hypervisor to domains (also called virtual machines), providing a modern alternative to older VM architectures that use a "thick", monolithic hypervisor. This permits a simpler hypervisor design, which enhances reliability, and security. It also reduces single points of failure by assigning responsibilities to multiple system components, further improving reliability and security. Oracle VM Server for SPARC defines the following types of domain, each with their own roles: Control domain - management control point for the server, runs the logical domain daemon and constraints engine, and is used to configure domains and manage resources. The control domain is the first domain to boot on a power-up, is always an I/O domain, and is usually a service domain as well. It doesn't have to be, but there's no reason to not leverage it for virtual I/O services. There is one control domain per T-series system, and one per Physical Domain (PDom) on an M5-32 or M6-32 system. M5 and M6 systems can be physically domained, with logical domains within the physical ones. I/O domain - a domain that has been assigned physical I/O devices. The devices may be one more more PCIe root complexes (in which case the domain is also called a root complex domain). The domain has native access to all the devices on the assigned PCIe buses. The devices can be any device type supported by Solaris on the hardware platform. a SR-IOV (Single-Root I/O Virtualization) function. SR-IOV lets a physical device (also called a physical function) or PF) be subdivided into multiple virtual functions (VFs) which can be individually assigned directly to domains. SR-IOV devices currently can be Ethernet or InfiniBand devices. direct I/O ownership of one or more PCI devices residing in a PCIe bus slot. The domain has direct access to the individual devices An I/O domain has native performance and functionality for the devices it owns, unmediated by any virtualization layer. It may also have virtual devices. Service domain - a domain that provides virtual network and disk devices to guest domains. The services are defined by commands that are run in the control domain. It usually is an I/O domain as well, in order for it to have devices to virtualize and serve out. Guest domain - a domain whose devices are all virtual rather than physical: virtual network and disk devices provided by one or more service domains. In common practice, this is where applications are run. Device considerations Consider the following when choosing between virtual devices and physical devices: Virtual devices provide the best flexibility - they can be dynamically added to and removed from a running domain, and you can have a large number of them up to a per-domain device limit. Virtual devices are compatible with live migration - domains that exclusively have virtual devices can be live migrated between servers supporting domains. On the other hand: Physical devices provide the best performance - in fact, native "bare metal" performance. Virtual devices approach physical device throughput and latency, especially with virtual network devices that can now saturate 10GbE links, but physical devices are still faster. Physical I/O devices do not add load to service domains - all the I/O goes directly from the I/O domain to the device, while virtual I/O goes through service domains, which must be provided sufficient CPU and memory capacity. Physical I/O devices can be other than network and disk - we virtualize network, disk, and serial console, but physical devices can be the wide range of attachable certified devices, including things like tape and CDROM/DVD devices. In some cases the lines are now blurred: virtual devices have better performance than previously: starting with Oracle VM Server for SPARC 3.1 there is near-native virtual network performance. There is more flexibility with physical devices than before: SR-IOV devices can now be dynamically reconfigured on domains. Tradeoffs one used to have to make are now relaxed: you can often have the flexibility of virtual I/O with performance that previously required physical I/O. You can have the performance and isolation of SR-IOV with the ability to dynamically reconfigure it, just like with virtual devices. Typical deployment A service domain is generally also an I/O domain: otherwise it wouldn't have access to physical device "backends" to offer to its clients. Similarly, an I/O domain is also typically a service domain in order to leverage the available PCI buses. Control domains must be I/O domains, because they boot up first on the server and require physical I/O. It's typical for the control domain to also be a service domain too so it doesn't "waste" the I/O resources it uses. A simple configuration consists of a control domain that is also the one I/O and service domain, and some number of guest domains using virtual I/O. In production, customers typically use multiple domains with I/O and service roles to eliminate single points of failure, as described in Availability Best Practices - Avoiding Single Points of Failure . Guest domains have virtual disk and virtual devices provisioned from more than one service domain, so failure of a service domain or I/O path or device does not result in an application outage. This also permits "rolling upgrades" in which service domains are upgraded one at a time while their guests continue to operate without disruption. (It should be noted that resiliency to I/O device failures can also be provided by the single control domain, using multi-path I/O) In this type of deployment, control, I/O, and service domains are used for virtualization infrastructure, while applications run in guest domains. Changing application deployment patterns The above model has been widely and successfully used, but more configuration options are available now. Servers got bigger than the original T2000 class machines with 2 I/O buses, so there is more I/O capacity that can be used for applications. Increased server capacity made it attractive to run more vertically-scaled applications, such as databases, with higher resource requirements than the "light" applications originally seen. This made it attractive to run applications in I/O domains so they could get bare-metal native I/O performance. This is leveraged by the Oracle SuperCluster engineered systems mentioned previously. In those engineered systems, I/O domains are used for high performance applications with native I/O performance for disk and network and optimized access to the Infiniband fabric. Another technical enhancement is Single Root I/O Virtualization (SR-IOV), which make it possible to give domains direct connections and native I/O performance for selected I/O devices. Not all I/O domains own PCI complexes, and there are increasingly more I/O domains that are not service domains. They use their I/O connectivity for performance for their own applications. However, there are some limitations and considerations: at this time, a domain using physical I/O cannot be live-migrated to another server. There is also a need to plan for security and introducing unneeded dependencies: if an I/O domain is also a service domain providing virtual I/O to guests, it has the ability to affect the correct operation of its client guest domains. This is even more relevant for the control domain. where the ldm command must be protected from unauthorized (or even mistaken) use that would affect other domains. As a general rule, running applications in the service domain or the control domain should be avoided. For reference, an excellent guide to secure deployment of domains by Stefan Hinker is at Secure Deployment of Oracle VM Server for SPARC. To recap: Guest domains with virtual I/O still provide the greatest operational flexibility, including features like live migration. They should be considered the default domain type to use unless there is a specific requirement that mandates an I/O domain. I/O domains can be used for applications with the highest performance requirements. Single Root I/O Virtualization (SR-IOV) makes this more attractive by giving direct I/O access to more domains, and by permitting dynamic reconfiguration of SR-IOV devices. Today's larger systems provide multiple PCIe buses - for example, 16 buses on the T5-8 - making it possible to configure multiple I/O domains each owning their own bus. Service domains should in general not be used for applications, because compromised security in the domain, or an outage, can affect domains that depend on it. This concern can be mitigated by providing guests' their virtual I/O from more than one service domain, so interruption of service in one service domain does not cause an application outage. The control domain should in general not be used to run applications, for the same reason. Oracle SuperCluster uses the control domain for applications, but it is an exception. It's not a general purpose environment; it's an engineered system with specifically configured applications and optimization for optimal performance. These are recommended "best practices" based on conversations with a number of Oracle architects. Keep in mind that "one size does not fit all", so you should evaluate these practices in the context of your own requirements. Summary Higher capacity servers that run Oracle VM Server for SPARC are attractive for applications with the most demanding resource requirements. New deployment models permit native I/O performance for demanding applications by running them in I/O domains with direct access to their devices. This is leveraged in SPARC SuperCluster, and can be leveraged in T-series servers to provision high-performance applications running in domains. Carefully planned, this can be used to provide peak performance for critical applications. That said, the improved virtual device performance in Oracle VM Server means that the default choice should still be guest domains with virtual I/O.

    Read the article

  • SQL SERVER – New SQL Server 2012 Functions – Webinar by Rick Morelan

    - by Pinal Dave
    My friend Rick Morelan is a wonderful speaker and listening to him is very delightful. Rick is one of the speakers who can articulate a very complex subject in very simple words. Rick has attained over 30 Microsoft certifications in applications, networking, databases and .NET development, including MCDBA, MCTS, MCITP, MCAD, MOE, MCSE and MCSE+. Here is the chance for every one who has not listened Rick Morelan before as he is presenting an online webinar on New SQL Server 2012 Functions. Whether or not you’re a database developer or administrator, you love the power of SQL functions. The functions in SQL Server give you the power to accelerate your applications and database performance. Each version of SQL Server adds new functionality, so come and see Rick Morelan explain what’s new in SQL Server 2012! This webinar will focus on the new string, time and logical functions added to SQL Server 2012. Register for the webinar now to learn: SQL Server 2012 function basics String, time and logical function details Tools to accelerate the SQL coding process Tuesday June 11, 2013  7:00 AM PDT / 10:00 AM EDT 11:00 AM PDT / 2:00 PM EDT Secret Hint: Here is something I would like to tell everyone that there is a quiz coming up on SQLAuthority.com and those who will attend the webinar will find it very easy to resolve it. Register for webinar Reference: Pinal Dave (http://blog.sqlauthority.com) Filed under: Joes 2 Pros, PostADay, SQL, SQL Authority, SQL Query, SQL Server, SQL Tips and Tricks, T SQL, Technology

    Read the article

  • RAID5 over LVM on Ubuntu Server 12.04.3

    - by April Ethereal
    I'm trying to create a RAID5 software array using LVM. I use VirtualBox as I'm only learning how LVM works. So I've created 4 virtual SCSI drives and then did the following: pvcreate /dev/sd[b-e] vgcreate /dev/sd[b-e] raid5_vg lvcreate --type raid5 -i 3 -L 1G -n raid_lv raid5_vg However, I get an error after the last command: WARNING: Unrecognised segment type raid5 Using default stripesize 64.00 KiB Rounding size (256 extents) up to stripe boundary size (258 extents) Cannot update volume group raid5_vg with unknown segments in it! So it looks like raid5 is not a valid segment type. "lvm segtypes" also doesn't contain 'raid5' entry: root@ubuntu-lvm:~# lvm segtypes striped zero error free snapshot mirror So my question is - how could I create RAID5 logical volume using LVM only? It seems that it is possible, I saw a few references (not for Ubuntu, unfortunately) for RedHat and Gentoo systems. I don't want to use mdadm for now, until I find out that it is mandatory. Some info about my system is below: root@ubuntu-lvm:~# uname -a Linux ubuntu-lvm 3.8.0I use Ubuntu Server 12.04.3 (i686)-29-generic #42~precise1-Ubuntu SMP Wed Aug 14 15:31:16 UTC 2013 i686 i686 i386 GNU/Linux root@ubuntu-lvm:~# dpkg -l | grep lvm ii lvm2 2.02.66-4ubuntu7.3 The Linux Logical Volume Manager Thanks.

    Read the article

  • wireless detected but Can't connect to network, Wifi card intel pro wireless N100 BGN

    - by Alexandre777
    Thanks in advance, I installed Linux Mint kernel 3.0.0-12 x64 ,wireless is detected and I configure it in network manager but can't coonect, there are the results of command line: $ iwconfig lo no wireless extensions. eth0 no wireless extensions. wlan0 IEEE 802.11bgn ESSID:off/any Mode:Managed Access Point: Not-Associated Tx-Power=off Retry long limit:7 RTS thr:off Fragment thr:off Power Management:off $ sudo lshw -C network** *-network description: Wireless interface product: Centrino Wireless-N 1000 vendor: Intel Corporation physical id: 0 bus info: pci@0000:03:00.0 logical name: wlan0 version: 00 serial: 00:1e:64:51:c9:d6 width: 64 bits clock: 33MHz capabilities: pm msi pciexpress bus_master cap_list ethernet physical wireless configuration: broadcast=yes driver=iwlagn driverversion=3.0.0-12-generic firmware=39.31.5.1 build 35138 latency=0 link=no multicast=yes wireless=IEEE 802.11bgn resources: irq:48 memory:d7400000-d7401fff *-network description: Ethernet interface product: AR8131 Gigabit Ethernet vendor: Atheros Communications physical id: 0 bus info: pci@0000:06:00.0 logical name: eth0 version: c0 serial: 48:5b:39:99:8f:16 size: 100Mbit/s capacity: 1Gbit/s width: 64 bits clock: 33MHz capabilities: pm msi pciexpress vpd bus_master cap_list ethernet physical tp 10bt 10bt-fd 100bt 100bt-fd 1000bt-fd autonegotiation configuration: autonegotiation=on broadcast=yes driver=atl1c driverversion=1.0.1.0-NAPI duplex=full firmware=N/A ip=192.168.1.2 latency=0 link=yes multicast=yes port=twisted pair speed=100Mbit/s resources: irq:51 memory:d3800000-d383ffff ioport:8000(size=128 $ rfkill list all 0: phy0: Wireless LAN Soft blocked: no Hard blocked: no Thank you.

    Read the article

< Previous Page | 14 15 16 17 18 19 20 21 22 23 24 25  | Next Page >