Search Results

Search found 10719 results on 429 pages for 'hardware failure'.

Page 190/429 | < Previous Page | 186 187 188 189 190 191 192 193 194 195 196 197  | Next Page >

  • hp smart array lock up code 0x15, what is that? (or where can I get a list of descriptions of HP smart array controller lock up codes)

    - by user47650
    Hi, I've had a couple of Dl180 6g boxes hung over the last week, each have a P410 smart array controller. upon reboot the server has indicated that a controller failure event occurred and the previous lock up code was 0x15 - the server rebooted without issue. However there was nothing in the IML log, but the ADU report provided the following; Trap Address High Or Post Results Lockup Reason Or Post Error RIS Updates Or Post Error Detail Firmware Version Trap Address Low 0x8087 0x0015 0x0000033e 0x015e 0xd65c any suggestions on what that code is, my google fu failed. And hp support have not responded with any detail as yet.

    Read the article

  • Old operational master still thinks it is the "one"

    - by Doug
    Hi there, I have a domain with 3 AD servers for now i'll just call them: AD01 (Win 2008 GC, Operations master) AD02 (Win 2008 GC) AD03 (Win 2003 GC) A couple of months there was some hardware issues with AD01 so the operations master, PDC and Infrastructure Master was moved to AD02. All machines where on while this was happening. AD01 (Win 2008 GC) AD02 (Win 2008 GC, Operations master) AD03 (Win 2003 GC) AD01 was then shutdown for a month. Upon starting this machine up with replaced hardware (NIC and RAID card) i now have a weird problem. AD01 Thinks it is operations master still in AD on the local box AD02 & AD03 Thinks AD02 is operations master in AD on both boxes When running DCDIAG on AD01 i get a number of issues (listed below) When running "dcdiag /test:advertising" on AD01: Doing primary tests Testing server: Default-First-Site-Name\AD01 Starting test: Advertising Warning: DsGetDcName returned information for \\ad02.domain.local, when we were trying to reach AD01. SERVER IS NOT RESPONDING or IS NOT CONSIDERED SUITABLE. ......................... AD01 failed test Advertising Running partition tests on : ForestDnsZones Running partition tests on : DomainDnsZones Running partition tests on : Schema Running partition tests on : Configuration Running partition tests on : domain Running enterprise tests on : domain.local When running "dcdiag" on AD01 i get the following errors (excerpt of the Final output): Testing server: Default-First-Site-Name\AD01 Starting test: Advertising Warning: DsGetDcName returned information for \\ad02.domain.local, when we were trying to reach AD01. SERVER IS NOT RESPONDING or IS NOT CONSIDERED SUITABLE. ......................... AD01 failed test Advertising Starting test: FrsEvent There are warning or error events within the last 24 hours after the SYSVOL has been shared. Failing SYSVOL replication problems may cause Group Policy problems. Starting test: NCSecDesc Error NT AUTHORITY\ENTERPRISE DOMAIN CONTROLLERS doesn't have Replicating Directory Changes In Filtered Set access rights for the naming context: DC=ForestDnsZones,DC=domain,DC=local Error NT AUTHORITY\ENTERPRISE DOMAIN CONTROLLERS doesn't have Replicating Directory Changes In Filtered Set access rights for the naming context: DC=DomainDnsZones,DC=domain,DC=local Starting test: Replications [Replications Check,Replications Check] Inbound replication is disabled. To correct, run "repadmin /options AD01 -DISABLE_INBOUND_REPL" [Replications Check,AD01] Outbound replication is disabled. To correct, run "repadmin /options AD01 -DISABLE_OUTBOUND_REPL" So the problem appeasr to be that when i moved the operations master, AD01 never got the memo, and now that it's started up, all the other AD servers don't think its the boss anymore when it trys to replicate etc. So i really need to manually update AD01 so that it knows who the operations master, instrastructure and PDC is - but i'm not having any luck I've been googling for nearly a day and all solutions lead to "the cake is a lie" Your ninja skills will be greatly appreciated

    Read the article

  • HomeMade/DIY NAS solution

    - by MicTech
    Has anyone experience with building NAS (Network-attached storage) for home/small office using? What component would you recommend? Hardware CPU motherboard HDDs RAID controller etc. Software OS FTP HTTP etc.

    Read the article

  • OSX 10.6.6 SSH md5 break-in check

    - by Alex
    Information Recently one of the linux servers that I access was compromised to steal passwords and ssh keys using a modified ssh binary. This lead me to question if the attacker had compromised my OSX Laptop which had ssh access turned on. A sophos virus scan turned up nothing, and I did not have rkhunter installed before the attack, so I could not compare hashes of the system binaries to be sure. However because OSX is relatively standard for each of their major releases, I asked fiends for md5 hashes md5 /usr/bin/ssh and md5 /usr/sbin/sshd as a basic first check to see if there was anything different about my machine. A few emails later I have found the following data: Version (Arch) [N] MD5 (/usr/bin/ssh) MD5 (/usr/sbin/sshd) OSX 10.5.8 (PPC) [3] 1e9fd483eef23464ec61c815f7984d61 9d32a36294565368728c18de466e69f1 OSX 10.5.8 (intel) [5] 1e9fd483eef23464ec61c815f7984d61 9d32a36294565368728c18de466e69f1 OSX 10.6.x (intel) [7] 591fbe723011c17b6ce41c537353b059 e781fad4fc86cf652f6df22106e0bf0e OSX 10.6.x (intel) [4] 58be068ad5e575c303ec348a1c71d48b 33dafd419194b04a558c8404b484f650 Mine 10.6.6 (intel) df344cc00a294c91230c65e8b7332a79 b5094ccf4cd074aaf573d4f5df75906a where N is the number of machines with with that MD5, and the last row is my laptop. The sample is relatively heterogeneous spaning a few years of different makes and models of Apples, and different versions of 10.6.x. The different hash for my system made me worried that these binaries might have been compromised. So I made sure that my backup for the week was good, and dived into formatting my system and reinstalling OSX. After reinstalling OSX from the manufacturer DVD, I found that the MD5 hash did not change for either ssh, or sshd. Goal Make sure that my system is does not have any malicious software. Should I be worried that this base install of OSX (with no other software installed) has been compromised? I have also updated my system to 10.6.6 and found no change as well. Other Information I am not sure if this is helpful information, but my laptop is a i7 15 inch MacBook Pro bought in Nov 2010, and here is some output from system_profiler: System Software Overview: System Version: Mac OS X 10.6.6 (10J567) Kernel Version: Darwin 10.6.0 64-bit Kernel and Extensions: No Time since boot: 1:37 Hardware: Hardware Overview: Model Name: MacBook Model Identifier: MacBook6,2 Processor Name: Intel Core i7 Processor Speed: 2.66 GHz Number Of Processors: 1 Total Number Of Cores: 2 L2 Cache (per core): 256 KB L3 Cache: 4 MB Memory: 4 GB Processor Interconnect Speed: 4.8 GT/s Boot ROM Version: MBP61.0057.B0C SMC Version (system): 1.58f16 Sudden Motion Sensor: State: Enabled On the laptop, I find: $ codesign -vvv /usr/bin/ssh /usr/bin/ssh: valid on disk /usr/bin/ssh: satisfies its Designated Requirement $ codesign -vvv /usr/sbin/sshd /usr/sbin/sshd: valid on disk /usr/sbin/sshd: satisfies its Designated Requirement $ ls -la /usr/bin/ssh -rwxr-xr-x 1 root wheel 1001520 Feb 11 2010 /usr/bin/ssh $ ls -la /usr/sbin/sshd -rwxr-xr-x 1 root wheel 1304800 Feb 11 2010 /usr/sbin/sshd $ ls -la /sbin/md5 -r-xr-xr-x 1 root wheel 65232 May 18 2009 /sbin/md5 Update So far I have not gotten an answer about this question, but if you could help by increasing the number of hashes that I can compare against, that would be great. To get hashes, and version numbers, run the following on osx: md5 /usr/bin/ssh md5 /usr/sbin/sshd ssh -V sw_vers

    Read the article

  • How to troubleshoot a GPF?

    - by AngryHacker
    I get a GPF dialog box out of the blue fairly often (like about 2 hours after I turn on the computer). It basically says that svchost.exe had a failure... (see the corresponding Event Log entry below). Event Type: Error Event Source: Application Error Event Category: (100) Event ID: 1000 Date: 5/18/2010 Time: 7:41:16 PM User: N/A Computer: DKHA-IPSA Description: Faulting application svchost.exe, version 5.1.2600.5512, faulting module ole32.dll, version 5.1.2600.5512, fault address 0x0004eaa9. Shortly after this error pops up, the computer pretty much grinds to a halt (e.g. some UI elements on the desktop simply do not respond). And I have to do a hard reboot. How do I troubleshoot this type of thing? P.S. The PC has all the latest patches and nothing is missing in the Device Manager.

    Read the article

  • About HDD enclosure

    - by kmitnick
    hey guys, how r u doin? I have this 3.5" IDE enclosure, and it works great, I mean I love the idea of enclosures ( not the power feeding thing :), btw can't I just insert a chargable battery to feed the power when I am unable to find an electricity block), anyway my question is, when I finish the usage of the enclosure I safely remove it when using Windows or umount when working with Linux, and after that I got confused whether to turn it off or no? when I turn it off, the HDD suddenly stop spinning as if power failure not as when it was an internal and normally shuted down the pc. So is it ok to turn it off the way I've just said??? regards, ~Abed

    Read the article

  • Boot disc Dual-Core CPU stress tool

    - by Ssvarc
    Looking for a tool that can test a daul-core cpu via a boot disc, thus bypassing Windows (and ensuring that only the hardware is being tested). UBCD4Win's included Prime95 is an older version and it can't run two threads at once. Ditto for UBCD. Any idea? And while I'm asking, is there a boot tool for GPU's? Thanks!

    Read the article

  • mac osx cannot connect to windows 7 machine

    - by Binary X
    I have a Mac OSX (Snow Leopard 10.6.6) setup on a network with several Windows 7 machines. When trying to place a large file on a Windows share the connection to the Windows share gets lost and I am unable to reconnect until I reboot the Mac. I know this is on the Windows side because the Mac can connect and transfer files to Server 2008 and XP without issue. Looking in the log file I see this message SharePointBrowser::handleOpenCallBack returned 12 I have tried restarting the com.apple.netauth.sysagent service but that did not resolve the situation. I can do an nslookup to the Windows 7 machine, but trying to ping the machine by hostname always gives a hostname lookup failure (I can ping via IP address). I cannot connect to the machine via IP adress either. Any help would be appreciated.

    Read the article

  • sqlcmd won't execute - Claims Native Client not installed properly

    - by nuit9
    I'm trying to use sqlcmd to execute some SQL scripts. Using a test command with a simple query like: sqlcmd -S HOSTNAME -d MYDATABASE -Q 'SELECT Names FROM Customers' sqlcmd does not appear to make any attempt to connect to the server as it displays this message: Sqlcmd: Error: Connection failure. SQL Native Client is not installed correctly. To correct this, run SQL Server Setup. The native client was presumably installed as part of the SQL Server setup and likely correctly. I actually get this message on any machine with SQL server installed trying to use sqlcmd so it's not a matter of the installation being corrupt. Unfortunately the message really tells me nothing about the problem so I don't know what the real issue is. I know the SQL Native client is working properly since a vbscript was able to execute SQL queries against the database. Is there some additional configuration needed to use sqlcmd?

    Read the article

  • Fastest router for OpenWRT/etc?

    - by marienbad
    I realize OpenWRT Wiki hardware info tells CPU model and MHz for many routers, but MHz doesn't directly map to speed. So... as far as you know, what are some of the fastest OpenWRT-compatible wifi routers out there?

    Read the article

  • Display Driver stopped responding and recovered successfully- Blue Screen - HP Elite Book

    - by Fahad Saleem
    I have HP ELiteBook , this problem has become a routine headache for me (after every 20, 25 minutes_ - While using, suddenly everything hangs and black out goes around and then a message pop at the task bar below that display driver stopped ...and successfully recovered but the hangs and black screen continues and then the Blue Death Screen comes" and then i have no other option but to restart Is this a driver problem ? Hardware problem ? what should I do Please be specific , no stories and theories

    Read the article

  • HP DL360 G6 NC328i Dual Port Gigabit - Windows Server 2003 R2 Driver Problem

    - by brianjd
    I recently installed Windows Server 2003 R2 (64) on a DL360 G6 without using the SmartStart CD (it didn't like the MSDN media). But when I attempted to install the network drivers post-install using the packages from the HP website, I wasn't successful. Though I selected the correct package, the installer reported I did not have the necessary hardware configuration. Has anyone had a similar experience? Thanks

    Read the article

  • LVM2 vs MDADM performance

    - by archer
    I've used MDADM + LVM2 on many boxes for quite a while. MDADM was serving for both RAID0 and RAID1 arrays, while LVM2 where used for logical volumes on top of MDADM. Recently I've found that LVM2 could be used w/o MDADM (thus minus one layer, as the result - less overhead) for both mirroring and stripping. However, some guys claims that READ PERFORMANCE on LVM2 for mirrored array is not that fast as for LVM2 (linear) on top of MDADM (RAID1) as LVM2 does not read from 2+ devices at a time, but use 2nd and higher devices in case of 1st device failure. MDADM reads from 2 devices at a time (even in mirrored mode). Who could confirm that?

    Read the article

  • OCS 2007: Issues with /LiveServer/MCUFactory

    - by routeNpingme
    I'm not really an Office Communications Server expert, but just trying to resolve some seemingly minor issues with a new install... The following error is occurring in the OCS event log, and when I try to visit https://servername:444/LiveServer/MCUFactory in Internet Explorer to test the address, I just get a "page cannot be displayed" error. I can telnet to port 444 on the server and verify that the port is open and listening. Any ideas? Event Type: Error Event Source: OCS MCU Infrastructure Event Category: (1022) Event ID: 61013 Date: 7/28/2009 Time: 8:47:42 AM User: N/A Computer: COMM2 Description: The process DataMCUSvc(1284) failed to send health notifications to the MCU factory at https://servername:444/LiveServer/MCUFactory/. Failure occurrences: 29, since 7/28/2009 8:40:27 AM. For more information, see Help and Support Center at http://go.microsoft.com/fwlink/events.asp.

    Read the article

  • Load-balancer options

    - by toolkit
    I am looking at a number of possible options for load-balancing. So far, I am constrained to the following options: DNS server load-balancer, balancing to a cluster of tomcat servers, with terracotta for session replication. Pros - don't have to buy new kit. Cons - DNS lb can keep directing to a broken server. Hardware load-balancer, direct to cluster of tomcat servers. Pros - could have second box for failover lb. Cons - expense. Apache server load-balancer. Pros - apache's lb polls for broken servers. Cons - apache server is single point of failure, plus need to buy another server. Are there any other options I should consider? Thanks. Update: Thanks for all the answers so far +1's all round. Not accepting an answer yet, to keep more ideas coming.

    Read the article

  • How much time do I have to remove a domain controller that was lost using metadata cleanup?

    - by dasko
    I am wondering how long after a Domain Controller has been permanently lost, from the domain due to it dying from hardware perspective, do I have before I have to clean up references of it using meta data cleanup? Planning on doing it soon but not sure if there is anything I should be concerned about. This dead or lost domain controller had no roles other than being a Domain Controller and having integrated Active Directory DNS. As well it held NO FSMO roles, it was just an older replication Domain Controller.

    Read the article

  • Front audio jack not working or missconfigured?

    - by Nicholas
    I have win xp and asus p5ql-e motherboard. The problem is that when i plug in my headphones on the front audio jack, the computer doesn't recognizes it. They work on the back audio jack but not on the front - how can i be sure that it;s not a software problem (something miss configured or not configured at all), before i conclude that it's a hardware problem (broken front audio jack or miss connected to the motherboard)?

    Read the article

  • Oracle: FRM-41211 Error Message when starting a Report from Oracle Forms (64 Bit Windows Server)

    - by DB.
    After installing Oracle Forms and Reports 6.0 (Patch 18) on a Windows 2008 64 Bit server we get the following error when we try to start a report from Forms. "FRM-41211 integration error: ssl failure running another product" The problem is reproducable on another server using the same Windows OS. One of the proposed solutions (extending the REPORTS60_PATH) we have already tried but that did not help solving our problem. Another tip has been to shorten the content of the path variable before installing Oracle Forms and Reports. We will try this later on another server. Any other tips or solutions for this error would be very much appreciated.

    Read the article

  • Persistent Issues on small business network using Cisco 871W and Catalyst Express 500

    - by Ben Campbell
    Being the most qualified (read: still not qualified) to solve our persistant network issues, I've turned to serverfault for guidance. I've done some searching, reading related documentation on cisco.com and tried a bit of troubleshooting. Here is the config: 100mb synchronous connection from a business internet provider (tested multiple times at 100meg at the source) Cisco 871W wireless point & router is where the WAN connection starts (this serves all our wireless). The only wired connection in the 871W is the Catalyst switch listed below. Cisco Catalyst Express 500 (24TT) is where all the wired connections terminate. About 20 Windows workstations and servers (AD/Webservers only). Some services in EC2 including mail and other web servers/apps. I've been TOLD cabling internally should be gigabit-ready. Here are the problems: generally slow download rates from the internet to the desktop/laptop frequent "page cannot be displayed" errors in browsers-sometimes 3 or 4 reloads are necessary... often times CSS wont load or other content requiring the browser to connect to a different server. slow speed within the LAN from workstation to workstation copying files. I would expect extremely fast data transfer workstation to workstation / server to workstation in this simple network. Several things I need to admit: I'm not primarily a network guy. Funding is relatively low, I need to be the guy that finds the solution. I understand most of the terminology and most of the technology. Implementation is where I fail due to lack of experience. Getting to the point: I'm wondering whether experienced network admins think that our small network should be sufficiently served with our current hardware if configured properly... or if we should purchase new equipment and start fresh? If starting fresh is the plan, whatever that new equipment may be is a likely different question entirely. If I haven't provided enough information, I will happily do some troubleshooting and update with the results. I have experience using wireshark and some other tools. Please let me know what you think would be most helpful and thanks in advance. EDIT: I forgot to add that the Cisco applicance will not finish loading the SDM Express console. It hangs every time at the "populating modules... DHCP". It eventually crashes and closes. I've rebooted the hardware and this still happens.

    Read the article

  • Issue with IIS...SERVER APPLICATION UNAVAILABLE

    - by SVI
    My web application was running absolutely fine. Just 2 days back, I got an error saying. SERVER APPLICATION UNAVAILABLE I am pretty certain that nothing was changed on IIS. Unless my automatic Windows updates screwed it up completely. My event viewer had zillions of following errors in Application category. aspnet_wp.exe could not be started. The error code for the failure is C0000005. This error can be caused when the worker process account has insufficient rights to read the .NET Framework files. Please ensure that the .NET Framework is correctly installed and that the ACLs on the installation directory allow access to the configured account. I reinstalled IIS. After installing, i ran aspnet_regiis -i for framework v2 and now it throws error saying - The application could not be initialized properly. Any ideas what going on?

    Read the article

  • Is Splitting IDE hdds between Primary and Secondary faster?

    - by earlz
    Hello, I'm doing RAID 0 on two IDE harddrives (yes, this is old hardware). Will the harddrives be faster if I attach them separately so that one is on the Primary IDE controller and the other is on the Secondary IDE controller? Or would it just be as good as having them both on the Primary IDE as master and slave?

    Read the article

  • PostgreSQL server: 10k RPM SAS or Intel 520 Series SSD drives?

    - by Vlad
    We will be expanding the storage for a PostgreSQL server and one of the things we are considering is using SSDs (Intel 520 Series) instead of rotating discs (10k RPM). Price per GB is comparable and we expect improved performance, however we are concerned about longevity since our database usage pattern is quite write-heavy. We are also concerned about data corruption in case of power failure (due to SSDs write cache not flushing properly). We currently use RAID10 with 4 active HDDs (10k 146GB) and 1 spare configured in the controller. It's a HP DL380 G6 server with P410 Smart Array Controller and BBWC. What makes more sense: upgrading the drives to 300GB 10k RPM or using Intel 520 Series SSDs (240GB)?

    Read the article

  • Is post-sudden-power-loss filesystem corruption on an SSD drive's ext3 partition "expected behavior"?

    - by Jeremy Friesner
    My company makes an embedded Debian Linux device that boots from an ext3 partition on an internal SSD drive. Because the device is an embedded "black box", it is usually shut down the rude way, by simply cutting power to the device via an external switch. This is normally okay, as ext3's journalling keeps things in order, so other than the occasional loss of part of a log file, things keep chugging along fine. However, we've recently seen a number of units where after a number of hard-power-cycles the ext3 partition starts to develop structural issues -- in particular, we run e2fsck on the ext3 partition and it finds a number of issues like those shown in the output listing at the bottom of this Question. Running e2fsck until it stops reporting errors (or reformatting the partition) clears the issues. My question is... what are the implications of seeing problems like this on an ext3/SSD system that has been subjected to lots of sudden/unexpected shutdowns? My feeling is that this might be a sign of a software or hardware problem in our system, since my understanding is that (barring a bug or hardware problem) ext3's journalling feature is supposed to prevent these sorts of filesystem-integrity errors. (Note: I understand that user-data is not journalled and so munged/missing/truncated user-files can happen; I'm specifically talking here about filesystem-metadata errors like those shown below) My co-worker, on the other hand, says that this is known/expected behavior because SSD controllers sometimes re-order write commands and that can cause the ext3 journal to get confused. In particular, he believes that even given normally functioning hardware and bug-free software, the ext3 journal only makes filesystem corruption less likely, not impossible, so we should not be surprised to see problems like this from time to time. Which of us is right? Embedded-PC-failsafe:~# ls Embedded-PC-failsafe:~# umount /mnt/unionfs Embedded-PC-failsafe:~# e2fsck /dev/sda3 e2fsck 1.41.3 (12-Oct-2008) embeddedrootwrite contains a file system with errors, check forced. Pass 1: Checking inodes, blocks, and sizes Pass 2: Checking directory structure Invalid inode number for '.' in directory inode 46948. Fix<y>? yes Directory inode 46948, block 0, offset 12: directory corrupted Salvage<y>? yes Entry 'status_2012-11-26_14h13m41.csv' in /var/log/status_logs (46956) has deleted/unused inode 47075. Clear<y>? yes Entry 'status_2012-11-26_10h42m58.csv.gz' in /var/log/status_logs (46956) has deleted/unused inode 47076. Clear<y>? yes Entry 'status_2012-11-26_11h29m41.csv.gz' in /var/log/status_logs (46956) has deleted/unused inode 47080. Clear<y>? yes Entry 'status_2012-11-26_11h42m13.csv.gz' in /var/log/status_logs (46956) has deleted/unused inode 47081. Clear<y>? yes Entry 'status_2012-11-26_12h07m17.csv.gz' in /var/log/status_logs (46956) has deleted/unused inode 47083. Clear<y>? yes Entry 'status_2012-11-26_12h14m53.csv.gz' in /var/log/status_logs (46956) has deleted/unused inode 47085. Clear<y>? yes Entry 'status_2012-11-26_15h06m49.csv' in /var/log/status_logs (46956) has deleted/unused inode 47088. Clear<y>? yes Entry 'status_2012-11-20_14h50m09.csv' in /var/log/status_logs (46956) has deleted/unused inode 47073. Clear<y>? yes Entry 'status_2012-11-20_14h55m32.csv' in /var/log/status_logs (46956) has deleted/unused inode 47074. Clear<y>? yes Entry 'status_2012-11-26_11h04m36.csv.gz' in /var/log/status_logs (46956) has deleted/unused inode 47078. Clear<y>? yes Entry 'status_2012-11-26_11h54m45.csv.gz' in /var/log/status_logs (46956) has deleted/unused inode 47082. Clear<y>? yes Entry 'status_2012-11-26_12h12m20.csv.gz' in /var/log/status_logs (46956) has deleted/unused inode 47084. Clear<y>? yes Entry 'status_2012-11-26_12h33m52.csv.gz' in /var/log/status_logs (46956) has deleted/unused inode 47086. Clear<y>? yes Entry 'status_2012-11-26_10h51m59.csv.gz' in /var/log/status_logs (46956) has deleted/unused inode 47077. Clear<y>? yes Entry 'status_2012-11-26_11h17m09.csv.gz' in /var/log/status_logs (46956) has deleted/unused inode 47079. Clear<y>? yes Entry 'status_2012-11-26_12h54m11.csv.gz' in /var/log/status_logs (46956) has deleted/unused inode 47087. Clear<y>? yes Pass 3: Checking directory connectivity '..' in /etc/network/run (46948) is <The NULL inode> (0), should be /etc/network (46953). Fix<y>? yes Couldn't fix parent of inode 46948: Couldn't find parent directory entry Pass 4: Checking reference counts Unattached inode 46945 Connect to /lost+found<y>? yes Inode 46945 ref count is 2, should be 1. Fix<y>? yes Inode 46953 ref count is 5, should be 4. Fix<y>? yes Pass 5: Checking group summary information Block bitmap differences: -(208264--208266) -(210062--210068) -(211343--211491) -(213241--213250) -(213344--213393) -213397 -(213457--213463) -(213516--213521) -(213628--213655) -(213683--213688) -(213709--213728) -(215265--215300) -(215346--215365) -(221541--221551) -(221696--221704) -227517 Fix<y>? yes Free blocks count wrong for group #6 (17247, counted=17611). Fix<y>? yes Free blocks count wrong (161691, counted=162055). Fix<y>? yes Inode bitmap differences: +(47089--47090) +47093 +47095 +(47097--47099) +(47101--47104) -(47219--47220) -47222 -47224 -47228 -47231 -(47347--47348) -47350 -47352 -47356 -47359 -(47457--47488) -47985 -47996 -(47999--48000) -48017 -(48027--48028) -(48030--48032) -48049 -(48059--48060) -(48062--48064) -48081 -(48091--48092) -(48094--48096) Fix<y>? yes Free inodes count wrong for group #6 (7608, counted=7624). Fix<y>? yes Free inodes count wrong (61919, counted=61935). Fix<y>? yes embeddedrootwrite: ***** FILE SYSTEM WAS MODIFIED ***** embeddedrootwrite: ********** WARNING: Filesystem still has errors ********** embeddedrootwrite: 657/62592 files (24.4% non-contiguous), 87882/249937 blocks Embedded-PC-failsafe:~# Embedded-PC-failsafe:~# e2fsck /dev/sda3 e2fsck 1.41.3 (12-Oct-2008) embeddedrootwrite contains a file system with errors, check forced. Pass 1: Checking inodes, blocks, and sizes Pass 2: Checking directory structure Directory entry for '.' in ... (46948) is big. Split<y>? yes Missing '..' in directory inode 46948. Fix<y>? yes Setting filetype for entry '..' in ... (46948) to 2. Pass 3: Checking directory connectivity '..' in /etc/network/run (46948) is <The NULL inode> (0), should be /etc/network (46953). Fix<y>? yes Pass 4: Checking reference counts Inode 2 ref count is 12, should be 13. Fix<y>? yes Pass 5: Checking group summary information embeddedrootwrite: ***** FILE SYSTEM WAS MODIFIED ***** embeddedrootwrite: 657/62592 files (24.4% non-contiguous), 87882/249937 blocks Embedded-PC-failsafe:~# Embedded-PC-failsafe:~# e2fsck /dev/sda3 e2fsck 1.41.3 (12-Oct-2008) embeddedrootwrite: clean, 657/62592 files, 87882/249937 blocks

    Read the article

  • SAN typical MTBF

    - by Adrian K
    We're using a SAN on a project at work, and there's a bit of debate around the fact that's technically it's a Single Point of Failure. No one seems to have any hard data. The SAN in question is a single physical box, but with internal redundant components (sorry - not sure3 what level of RAID it has, but I can find out). What's the tyopical MTBF for a SAN? The PM has it down on the projects risk register as "Quite Common' - I've never heard of a SAN going down, but I don't jhave any stats to show how likely it really is. Does anyone have any helpful info?

    Read the article