Search Results

Search found 29990 results on 1200 pages for 'object recognition'.

Page 211/1200 | < Previous Page | 207 208 209 210 211 212 213 214 215 216 217 218  | Next Page >

  • How can I keep a graphics object centered (like a circle) when zooming in or out on it?

    - by sonny5
    using System; using System.Drawing; using System.Collections; using System.ComponentModel; using System.Windows.Forms; using System.Data; using System.Drawing.Drawing2D; using System.Drawing.Imaging; namespace testgrfx { public class Form1 : System.Windows.Forms.Form { float m_Scalef; float m_Scalefout; Rectangle m_r1; private System.Windows.Forms.Button button2; private System.Windows.Forms.Button button3; private System.ComponentModel.Container components = null; private void InitializeComponent() { m_Scalef = 1.0f; // for zooming purposes Console.WriteLine("opening m_Scalef= {0}",m_Scalef); m_Scalefout = 1.0f; Console.WriteLine("opening m_Scalefout= {0}",m_Scalefout); m_r1 = new Rectangle(50,50,100,100); this.AutoScrollMinSize = new Size(600,700); this.components = new System.ComponentModel.Container(); this.button2 = new System.Windows.Forms.Button(); this.button2.BackColor = System.Drawing.Color.LightGray; this.button2.Location = new System.Drawing.Point(120, 30); this.button2.Name = "button2"; this.button2.Size = new System.Drawing.Size(72, 24); this.button2.TabIndex = 1; this.button2.Text = "Zoom In"; this.button2.Click += new System.EventHandler(this.mnuZoomin_Click); this.Controls.Add(button2); this.button3 = new System.Windows.Forms.Button(); this.button3.BackColor = System.Drawing.Color.LightGray; this.button3.Location = new System.Drawing.Point(200, 30); this.button3.Name = "button3"; this.button3.Size = new System.Drawing.Size(72, 24); this.button3.TabIndex = 2; this.button3.Text = "Zoom Out"; this.button3.Click += new System.EventHandler(this.mnuZoomout_Click); this.Controls.Add(button3); //InitMyForm(); } public Form1() { InitializeComponent(); Text = " DrawLine"; BackColor = SystemColors.Window; // Gotta load these kind at start-up ... not with button assignments this.Paint+=new PaintEventHandler(this.Form1_Paint); } static void Main() { Application.Run(new Form1()); } /// Clean up any resources being used. protected override void Dispose( bool disposing ) { if( disposing ) { if (components != null) { components.Dispose(); } } base.Dispose( disposing ); } // autoscroll2.cs does work private void Form1_Paint(object sender, System.Windows.Forms.PaintEventArgs e) { Graphics dc = e.Graphics; dc.PageUnit = GraphicsUnit.Pixel; dc.PageScale = m_Scalef; Console.WriteLine("opening dc.PageScale= {0}",dc.PageScale); dc.TranslateTransform(this.AutoScrollPosition.X/m_Scalef, this.AutoScrollPosition.Y/m_Scalef); Pen pn = new Pen(Color.Blue,2); dc.DrawEllipse(pn,m_r1); Console.WriteLine("form_paint_dc.PageUnit= {0}",dc.PageUnit); Console.WriteLine("form_paint_dc.PageScale= {0}",dc.PageScale); //Console.Out.NewLine = "\r\n\r\n"; // makes all double spaces } private void mnuZoomin_Click(object sender, System.EventArgs e) { m_Scalef = m_Scalef * 2.0f; Console.WriteLine("in mnuZoomin_Click m_Scalef= {0}",m_Scalef); Invalidate(); // to trigger Paint of entire client area } // try: System.Drawing.Rectangle resolution = Screen.GetWorkingArea(someForm); private void Form1_MouseDown(object sender, System.Windows.Forms.MouseEventArgs e) { // Uses the mouse wheel to scroll Graphics dc = CreateGraphics(); dc.TranslateTransform(this.AutoScrollPosition.X/m_Scalef, this.AutoScrollPosition.Y/m_Scalef); Console.WriteLine("opening Form1_MouseDown dc.PageScale= {0}", dc.PageScale); Console.WriteLine("Y wheel= {0}", this.AutoScrollPosition.Y/m_Scalef); dc.PageUnit = GraphicsUnit.Pixel; dc.PageScale = m_Scalef; Console.WriteLine("frm1_moudwn_dc.PageScale= {0}",dc.PageScale); Point [] mousep = new Point[1]; Console.WriteLine("mousep= {0}", mousep); // make sure to adjust mouse pos.for scroll position Size scrollOffset = new Size(this.AutoScrollPosition); mousep[0] = new Point(e.X-scrollOffset.Width, e.Y-scrollOffset.Height); dc.TransformPoints(CoordinateSpace.Page, CoordinateSpace.Device,mousep); Pen pen = new Pen(Color.Green,1); dc.DrawRectangle(pen,m_r1); Console.WriteLine("m_r1= {0}", m_r1); Console.WriteLine("mousep[0].X= {0}", mousep[0].X); Console.WriteLine("mousep[0].Y= {0}", mousep[0].Y); if (m_r1.Contains(new Rectangle(mousep[0].X, mousep[0].Y,1,1))) MessageBox.Show("click inside rectangle"); } private void Form1_Load(object sender, System.EventArgs e) { } private void mnuZoomout_Click(object sender, System.EventArgs e) { Console.WriteLine("first line--mnuZoomout_Click m_Scalef={0}",m_Scalef); if(m_Scalef > 9 ) { m_Scalef = m_Scalef / 2.0f; Console.WriteLine("in >9 mnuZoomout_Click m_Scalef= {0}",m_Scalef); Console.WriteLine("in >9 mnuZoomout_Click__m_Scalefout= {0}",m_Scalefout); } else { Console.WriteLine("<= 9_Zoom-out B-4 redefining={0}",m_Scalef); m_Scalef = m_Scalef * 0.5f; // make it same as previous Zoom In Console.WriteLine("<= 9_Zoom-out after m_Scalef= {0}",m_Scalef); } Invalidate(); } } // public class Form1 }

    Read the article

  • Is there a way to convert MS 2010 Equation to Object in MS Equation 3.0?

    - by Teodorescu
    I have a lot of equations (for faculty) written in MS Equation (button from right side) and saved it in .docx format. All good and the best until my professor told me that he has MS 2003 and I have to convert from docx to doc format and the equations must be editable. I don't have enough time to rewrite all the equations in MS Equation 3.0. Is there a way to convert from MS Equation to MS Equation 3.0 Object to be recognized and editable in Word 2003?

    Read the article

  • Creating STA COM compatible ASP.NET Applications

    - by Rick Strahl
    When building ASP.NET applications that interface with old school COM objects like those created with VB6 or Visual FoxPro (MTDLL), it's extremely important that the threads that are serving requests use Single Threaded Apartment Threading. STA is a COM built-in technology that allows essentially single threaded components to operate reliably in a multi-threaded environment. STA's guarantee that COM objects instantiated on a specific thread stay on that specific thread and any access to a COM object from another thread automatically marshals that thread to the STA thread. The end effect is that you can have multiple threads, but a COM object instance lives on a fixed never changing thread. ASP.NET by default uses MTA (multi-threaded apartment) threads which are truly free spinning threads that pay no heed to COM object marshaling. This is vastly more efficient than STA threading which has a bit of overhead in determining whether it's OK to run code on a given thread or whether some sort of thread/COM marshaling needs to occur. MTA COM components can be very efficient, but STA COM components in a multi-threaded environment always tend to have a fair amount of overhead. It's amazing how much COM Interop I still see today so while it seems really old school to be talking about this topic, it's actually quite apropos for me as I have many customers using legacy COM systems that need to interface with other .NET applications. In this post I'm consolidating some of the hacks I've used to integrate with various ASP.NET technologies when using STA COM Components. STA in ASP.NET Support for STA threading in the ASP.NET framework is fairly limited. Specifically only the original ASP.NET WebForms technology supports STA threading directly via its STA Page Handler implementation or what you might know as ASPCOMPAT mode. For WebForms running STA components is as easy as specifying the ASPCOMPAT attribute in the @Page tag:<%@ Page Language="C#" AspCompat="true" %> which runs the page in STA mode. Removing it runs in MTA mode. Simple. Unfortunately all other ASP.NET technologies built on top of the core ASP.NET engine do not support STA natively. So if you want to use STA COM components in MVC or with class ASMX Web Services, there's no automatic way like the ASPCOMPAT keyword available. So what happens when you run an STA COM component in an MTA application? In low volume environments - nothing much will happen. The COM objects will appear to work just fine as there are no simultaneous thread interactions and the COM component will happily run on a single thread or multiple single threads one at a time. So for testing running components in MTA environments may appear to work just fine. However as load increases and threads get re-used by ASP.NET COM objects will end up getting created on multiple different threads. This can result in crashes or hangs, or data corruption in the STA components which store their state in thread local storage on the STA thread. If threads overlap this global store can easily get corrupted which in turn causes problems. STA ensures that any COM object instance loaded always stays on the same thread it was instantiated on. What about COM+? COM+ is supposed to address the problem of STA in MTA applications by providing an abstraction with it's own thread pool manager for COM objects. It steps in to the COM instantiation pipeline and hands out COM instances from its own internally maintained STA Thread pool. This guarantees that the COM instantiation threads are STA threads if using STA components. COM+ works, but in my experience the technology is very, very slow for STA components. It adds a ton of overhead and reduces COM performance noticably in load tests in IIS. COM+ can make sense in some situations but for Web apps with STA components it falls short. In addition there's also the need to ensure that COM+ is set up and configured on the target machine and the fact that components have to be registered in COM+. COM+ also keeps components up at all times, so if a component needs to be replaced the COM+ package needs to be unloaded (same is true for IIS hosted components but it's more common to manage that). COM+ is an option for well established components, but native STA support tends to provide better performance and more consistent usability, IMHO. STA for non supporting ASP.NET Technologies As mentioned above only WebForms supports STA natively. However, by utilizing the WebForms ASP.NET Page handler internally it's actually possible to trick various other ASP.NET technologies and let them work with STA components. This is ugly but I've used each of these in various applications and I've had minimal problems making them work with FoxPro STA COM components which is about as dififcult as it gets for COM Interop in .NET. In this post I summarize several STA workarounds that enable you to use STA threading with these ASP.NET Technologies: ASMX Web Services ASP.NET MVC WCF Web Services ASP.NET Web API ASMX Web Services I start with classic ASP.NET ASMX Web Services because it's the easiest mechanism that allows for STA modification. It also clearly demonstrates how the WebForms STA Page Handler is the key technology to enable the various other solutions to create STA components. Essentially the way this works is to override the WebForms Page class and hijack it's init functionality for processing requests. Here's what this looks like for Web Services:namespace FoxProAspNet { public class WebServiceStaHandler : System.Web.UI.Page, IHttpAsyncHandler { protected override void OnInit(EventArgs e) { IHttpHandler handler = new WebServiceHandlerFactory().GetHandler( this.Context, this.Context.Request.HttpMethod, this.Context.Request.FilePath, this.Context.Request.PhysicalPath); handler.ProcessRequest(this.Context); this.Context.ApplicationInstance.CompleteRequest(); } public IAsyncResult BeginProcessRequest( HttpContext context, AsyncCallback cb, object extraData) { return this.AspCompatBeginProcessRequest(context, cb, extraData); } public void EndProcessRequest(IAsyncResult result) { this.AspCompatEndProcessRequest(result); } } public class AspCompatWebServiceStaHandlerWithSessionState : WebServiceStaHandler, IRequiresSessionState { } } This class overrides the ASP.NET WebForms Page class which has a little known AspCompatBeginProcessRequest() and AspCompatEndProcessRequest() method that is responsible for providing the WebForms ASPCOMPAT functionality. These methods handle routing requests to STA threads. Note there are two classes - one that includes session state and one that does not. If you plan on using ASP.NET Session state use the latter class, otherwise stick to the former. This maps to the EnableSessionState page setting in WebForms. This class simply hooks into this functionality by overriding the BeginProcessRequest and EndProcessRequest methods and always forcing it into the AspCompat methods. The way this works is that BeginProcessRequest() fires first to set up the threads and starts intializing the handler. As part of that process the OnInit() method is fired which is now already running on an STA thread. The code then creates an instance of the actual WebService handler factory and calls its ProcessRequest method to start executing which generates the Web Service result. Immediately after ProcessRequest the request is stopped with Application.CompletRequest() which ensures that the rest of the Page handler logic doesn't fire. This means that even though the fairly heavy Page class is overridden here, it doesn't end up executing any of its internal processing which makes this code fairly efficient. In a nutshell, we're highjacking the Page HttpHandler and forcing it to process the WebService process handler in the context of the AspCompat handler behavior. Hooking up the Handler Because the above is an HttpHandler implementation you need to hook up the custom handler and replace the standard ASMX handler. To do this you need to modify the web.config file (here for IIS 7 and IIS Express): <configuration> <system.webServer> <handlers> <remove name="WebServiceHandlerFactory-Integrated-4.0" /> <add name="Asmx STA Web Service Handler" path="*.asmx" verb="*" type="FoxProAspNet.WebServiceStaHandler" precondition="integrated"/> </handlers> </system.webServer> </configuration> (Note: The name for the WebServiceHandlerFactory-Integrated-4.0 might be slightly different depending on your server version. Check the IIS Handler configuration in the IIS Management Console for the exact name or simply remove the handler from the list there which will propagate to your web.config). For IIS 5 & 6 (Windows XP/2003) or the Visual Studio Web Server use:<configuration> <system.web> <httpHandlers> <remove path="*.asmx" verb="*" /> <add path="*.asmx" verb="*" type="FoxProAspNet.WebServiceStaHandler" /> </httpHandlers> </system.web></configuration> To test, create a new ASMX Web Service and create a method like this: [WebService(Namespace = "http://foxaspnet.org/")] [WebServiceBinding(ConformsTo = WsiProfiles.BasicProfile1_1)] public class FoxWebService : System.Web.Services.WebService { [WebMethod] public string HelloWorld() { return "Hello World. Threading mode is: " + System.Threading.Thread.CurrentThread.GetApartmentState(); } } Run this before you put in the web.config configuration changes and you should get: Hello World. Threading mode is: MTA Then put the handler mapping into Web.config and you should see: Hello World. Threading mode is: STA And you're on your way to using STA COM components. It's a hack but it works well! I've used this with several high volume Web Service installations with various customers and it's been fast and reliable. ASP.NET MVC ASP.NET MVC has quickly become the most popular ASP.NET technology, replacing WebForms for creating HTML output. MVC is more complex to get started with, but once you understand the basic structure of how requests flow through the MVC pipeline it's easy to use and amazingly flexible in manipulating HTML requests. In addition, MVC has great support for non-HTML output sources like JSON and XML, making it an excellent choice for AJAX requests without any additional tools. Unlike WebForms ASP.NET MVC doesn't support STA threads natively and so some trickery is needed to make it work with STA threads as well. MVC gets its handler implementation through custom route handlers using ASP.NET's built in routing semantics. To work in an STA handler requires working in the Page Handler as part of the Route Handler implementation. As with the Web Service handler the first step is to create a custom HttpHandler that can instantiate an MVC request pipeline properly:public class MvcStaThreadHttpAsyncHandler : Page, IHttpAsyncHandler, IRequiresSessionState { private RequestContext _requestContext; public MvcStaThreadHttpAsyncHandler(RequestContext requestContext) { if (requestContext == null) throw new ArgumentNullException("requestContext"); _requestContext = requestContext; } public IAsyncResult BeginProcessRequest(HttpContext context, AsyncCallback cb, object extraData) { return this.AspCompatBeginProcessRequest(context, cb, extraData); } protected override void OnInit(EventArgs e) { var controllerName = _requestContext.RouteData.GetRequiredString("controller"); var controllerFactory = ControllerBuilder.Current.GetControllerFactory(); var controller = controllerFactory.CreateController(_requestContext, controllerName); if (controller == null) throw new InvalidOperationException("Could not find controller: " + controllerName); try { controller.Execute(_requestContext); } finally { controllerFactory.ReleaseController(controller); } this.Context.ApplicationInstance.CompleteRequest(); } public void EndProcessRequest(IAsyncResult result) { this.AspCompatEndProcessRequest(result); } public override void ProcessRequest(HttpContext httpContext) { throw new NotSupportedException("STAThreadRouteHandler does not support ProcessRequest called (only BeginProcessRequest)"); } } This handler code figures out which controller to load and then executes the controller. MVC internally provides the information needed to route to the appropriate method and pass the right parameters. Like the Web Service handler the logic occurs in the OnInit() and performs all the processing in that part of the request. Next, we need a RouteHandler that can actually pick up this handler. Unlike the Web Service handler where we simply registered the handler, MVC requires a RouteHandler to pick up the handler. RouteHandlers look at the URL's path and based on that decide on what handler to invoke. The route handler is pretty simple - all it does is load our custom handler: public class MvcStaThreadRouteHandler : IRouteHandler { public IHttpHandler GetHttpHandler(RequestContext requestContext) { if (requestContext == null) throw new ArgumentNullException("requestContext"); return new MvcStaThreadHttpAsyncHandler(requestContext); } } At this point you can instantiate this route handler and force STA requests to MVC by specifying a route. The following sets up the ASP.NET Default Route:Route mvcRoute = new Route("{controller}/{action}/{id}", new RouteValueDictionary( new { controller = "Home", action = "Index", id = UrlParameter.Optional }), new MvcStaThreadRouteHandler()); RouteTable.Routes.Add(mvcRoute);   To make this code a little easier to work with and mimic the behavior of the routes.MapRoute() functionality extension method that MVC provides, here is an extension method for MapMvcStaRoute(): public static class RouteCollectionExtensions { public static void MapMvcStaRoute(this RouteCollection routeTable, string name, string url, object defaults = null) { Route mvcRoute = new Route(url, new RouteValueDictionary(defaults), new MvcStaThreadRouteHandler()); RouteTable.Routes.Add(mvcRoute); } } With this the syntax to add  route becomes a little easier and matches the MapRoute() method:RouteTable.Routes.MapMvcStaRoute( name: "Default", url: "{controller}/{action}/{id}", defaults: new { controller = "Home", action = "Index", id = UrlParameter.Optional } ); The nice thing about this route handler, STA Handler and extension method is that it's fully self contained. You can put all three into a single class file and stick it into your Web app, and then simply call MapMvcStaRoute() and it just works. Easy! To see whether this works create an MVC controller like this: public class ThreadTestController : Controller { public string ThreadingMode() { return Thread.CurrentThread.GetApartmentState().ToString(); } } Try this test both with only the MapRoute() hookup in the RouteConfiguration in which case you should get MTA as the value. Then change the MapRoute() call to MapMvcStaRoute() leaving all the parameters the same and re-run the request. You now should see STA as the result. You're on your way using STA COM components reliably in ASP.NET MVC. WCF Web Services running through IIS WCF Web Services provide a more robust and wider range of services for Web Services. You can use WCF over HTTP, TCP, and Pipes, and WCF services support WS* secure services. There are many features in WCF that go way beyond what ASMX can do. But it's also a bit more complex than ASMX. As a basic rule if you need to serve straight SOAP Services over HTTP I 'd recommend sticking with the simpler ASMX services especially if COM is involved. If you need WS* support or want to serve data over non-HTTP protocols then WCF makes more sense. WCF is not my forte but I found a solution from Scott Seely on his blog that describes the progress and that seems to work well. I'm copying his code below so this STA information is all in one place and quickly explain. Scott's code basically works by creating a custom OperationBehavior which can be specified via an [STAOperation] attribute on every method. Using his attribute you end up with a class (or Interface if you separate the contract and class) that looks like this: [ServiceContract] public class WcfService { [OperationContract] public string HelloWorldMta() { return Thread.CurrentThread.GetApartmentState().ToString(); } // Make sure you use this custom STAOperationBehavior // attribute to force STA operation of service methods [STAOperationBehavior] [OperationContract] public string HelloWorldSta() { return Thread.CurrentThread.GetApartmentState().ToString(); } } Pretty straight forward. The latter method returns STA while the former returns MTA. To make STA work every method needs to be marked up. The implementation consists of the attribute and OperationInvoker implementation. Here are the two classes required to make this work from Scott's post:public class STAOperationBehaviorAttribute : Attribute, IOperationBehavior { public void AddBindingParameters(OperationDescription operationDescription, System.ServiceModel.Channels.BindingParameterCollection bindingParameters) { } public void ApplyClientBehavior(OperationDescription operationDescription, System.ServiceModel.Dispatcher.ClientOperation clientOperation) { // If this is applied on the client, well, it just doesn’t make sense. // Don’t throw in case this attribute was applied on the contract // instead of the implementation. } public void ApplyDispatchBehavior(OperationDescription operationDescription, System.ServiceModel.Dispatcher.DispatchOperation dispatchOperation) { // Change the IOperationInvoker for this operation. dispatchOperation.Invoker = new STAOperationInvoker(dispatchOperation.Invoker); } public void Validate(OperationDescription operationDescription) { if (operationDescription.SyncMethod == null) { throw new InvalidOperationException("The STAOperationBehaviorAttribute " + "only works for synchronous method invocations."); } } } public class STAOperationInvoker : IOperationInvoker { IOperationInvoker _innerInvoker; public STAOperationInvoker(IOperationInvoker invoker) { _innerInvoker = invoker; } public object[] AllocateInputs() { return _innerInvoker.AllocateInputs(); } public object Invoke(object instance, object[] inputs, out object[] outputs) { // Create a new, STA thread object[] staOutputs = null; object retval = null; Thread thread = new Thread( delegate() { retval = _innerInvoker.Invoke(instance, inputs, out staOutputs); }); thread.SetApartmentState(ApartmentState.STA); thread.Start(); thread.Join(); outputs = staOutputs; return retval; } public IAsyncResult InvokeBegin(object instance, object[] inputs, AsyncCallback callback, object state) { // We don’t handle async… throw new NotImplementedException(); } public object InvokeEnd(object instance, out object[] outputs, IAsyncResult result) { // We don’t handle async… throw new NotImplementedException(); } public bool IsSynchronous { get { return true; } } } The key in this setup is the Invoker and the Invoke method which creates a new thread and then fires the request on this new thread. Because this approach creates a new thread for every request it's not super efficient. There's a bunch of overhead involved in creating the thread and throwing it away after each thread, but it'll work for low volume requests and insure each thread runs in STA mode. If better performance is required it would be useful to create a custom thread manager that can pool a number of STA threads and hand off threads as needed rather than creating new threads on every request. If your Web Service needs are simple and you need only to serve standard SOAP 1.x requests, I would recommend sticking with ASMX services. It's easier to set up and work with and for STA component use it'll be significantly better performing since ASP.NET manages the STA thread pool for you rather than firing new threads for each request. One nice thing about Scotts code is though that it works in any WCF environment including self hosting. It has no dependency on ASP.NET or WebForms for that matter. STA - If you must STA components are a  pain in the ass and thankfully there isn't too much stuff out there anymore that requires it. But when you need it and you need to access STA functionality from .NET at least there are a few options available to make it happen. Each of these solutions is a bit hacky, but they work - I've used all of them in production with good results with FoxPro components. I hope compiling all of these in one place here makes it STA consumption a little bit easier. I feel your pain :-) Resources Download STA Handler Code Examples Scott Seely's original STA WCF OperationBehavior Article© Rick Strahl, West Wind Technologies, 2005-2012Posted in FoxPro   ASP.NET  .NET  COM   Tweet !function(d,s,id){var js,fjs=d.getElementsByTagName(s)[0];if(!d.getElementById(id)){js=d.createElement(s);js.id=id;js.src="//platform.twitter.com/widgets.js";fjs.parentNode.insertBefore(js,fjs);}}(document,"script","twitter-wjs"); (function() { var po = document.createElement('script'); po.type = 'text/javascript'; po.async = true; po.src = 'https://apis.google.com/js/plusone.js'; var s = document.getElementsByTagName('script')[0]; s.parentNode.insertBefore(po, s); })();

    Read the article

  • help with fixing fwts errors log

    - by jasmines
    Here is an extract of results.log: MTRR validation. Test 1 of 3: Validate the kernel MTRR IOMEM setup. FAILED [MEDIUM] MTRRIncorrectAttr: Test 1, Memory range 0xc0000000 to 0xdfffffff (PCI Bus 0000:00) has incorrect attribute Write-Combining. FAILED [MEDIUM] MTRRIncorrectAttr: Test 1, Memory range 0xfee01000 to 0xffffffff (PCI Bus 0000:00) has incorrect attribute Write-Protect. ==================================================================================================== Test 1 of 1: Kernel log error check. Kernel message: [ 0.208079] [Firmware Bug]: ACPI: BIOS _OSI(Linux) query ignored ADVICE: This is not exactly a failure mode but a warning from the kernel. The _OSI() method has implemented a match to the 'Linux' query in the DSDT and this is redundant because the ACPI driver matches onto the Windows _OSI strings by default. FAILED [HIGH] KlogACPIErrorMethodExecutionParse: Test 1, HIGH Kernel message: [ 3.512783] ACPI Error : Method parse/execution failed [\_SB_.PCI0.GFX0._DOD] (Node f7425858), AE_AML_PACKAGE_LIMIT (20110623/psparse-536) ADVICE: This is a bug picked up by the kernel, but as yet, the firmware test suite has no diagnostic advice for this particular problem. Found 1 unique errors in kernel log. ==================================================================================================== Check if system is using latest microcode. ---------------------------------------------------------------------------------------------------- Cannot read microcode file /usr/share/misc/intel-microcode.dat. Aborted test, initialisation failed. ==================================================================================================== MSR register tests. FAILED [MEDIUM] MSRCPUsInconsistent: Test 1, MSR SYSENTER_ESP (0x175) has 1 inconsistent values across 2 CPUs for (shift: 0 mask: 0xffffffffffffffff). MSR CPU 0 -> 0xf7bb9c40 vs CPU 1 -> 0xf7bc7c40 FAILED [MEDIUM] MSRCPUsInconsistent: Test 1, MSR MISC_ENABLE (0x1a0) has 1 inconsistent values across 2 CPUs for (shift: 0 mask: 0x400c51889). MSR CPU 0 -> 0x850088 vs CPU 1 -> 0x850089 ==================================================================================================== Checks firmware has set PCI Express MaxReadReq to a higher value on non-motherboard devices. ---------------------------------------------------------------------------------------------------- Test 1 of 1: Check firmware settings MaxReadReq for PCI Express devices. MaxReadReq for pci://00:00:1b.0 Audio device: Intel Corporation 82801I (ICH9 Family) HD Audio Controller (rev 03) is low (128) [Audio device]. MaxReadReq for pci://00:02:00.0 Network controller: Intel Corporation PRO/Wireless 5100 AGN [Shiloh] Network Connection is low (128) [Network controller]. FAILED [LOW] LowMaxReadReq: Test 1, 2 devices have low MaxReadReq settings. Firmware may have configured these too low. ADVICE: The MaxReadRequest size is set too low and will affect performance. It will provide excellent bus sharing at the cost of bus data transfer rates. Although not a critical issue, it may be worth considering setting the MaxReadRequest size to 256 or 512 to increase throughput on the PCI Express bus. Some drivers (for example the Brocade Fibre Channel driver) allow one to override the firmware settings. Where possible, this BIOS configuration setting is worth increasing it a little more for better performance at a small reduction of bus sharing. ==================================================================================================== PCIe ASPM check. ---------------------------------------------------------------------------------------------------- Test 1 of 2: PCIe ASPM ACPI test. PCIE ASPM is not controlled by Linux kernel. ADVICE: BIOS reports that Linux kernel should not modify ASPM settings that BIOS configured. It can be intentional because hardware vendors identified some capability bugs between the motherboard and the add-on cards. Test 2 of 2: PCIe ASPM registers test. WARNING: Test 2, RP 00h:1Ch.01h L0s not enabled. WARNING: Test 2, RP 00h:1Ch.01h L1 not enabled. WARNING: Test 2, Device 02h:00h.00h L0s not enabled. WARNING: Test 2, Device 02h:00h.00h L1 not enabled. PASSED: Test 2, PCIE aspm setting matched was matched. WARNING: Test 2, RP 00h:1Ch.05h L0s not enabled. WARNING: Test 2, RP 00h:1Ch.05h L1 not enabled. WARNING: Test 2, Device 85h:00h.00h L0s not enabled. WARNING: Test 2, Device 85h:00h.00h L1 not enabled. PASSED: Test 2, PCIE aspm setting matched was matched. ==================================================================================================== Extract and analyse Windows Management Instrumentation (WMI). Test 1 of 2: Check Windows Management Instrumentation in DSDT Found WMI Method WMAA with GUID: 5FB7F034-2C63-45E9-BE91-3D44E2C707E4, Instance 0x01 Found WMI Event, Notifier ID: 0x80, GUID: 95F24279-4D7B-4334-9387-ACCDC67EF61C, Instance 0x01 PASSED: Test 1, GUID 95F24279-4D7B-4334-9387-ACCDC67EF61C is handled by driver hp-wmi (Vendor: HP). Found WMI Event, Notifier ID: 0xa0, GUID: 2B814318-4BE8-4707-9D84-A190A859B5D0, Instance 0x01 FAILED [MEDIUM] WMIUnknownGUID: Test 1, GUID 2B814318-4BE8-4707-9D84-A190A859B5D0 is unknown to the kernel, a driver may need to be implemented for this GUID. ADVICE: A WMI driver probably needs to be written for this event. It can checked for using: wmi_has_guid("2B814318-4BE8-4707-9D84-A190A859B5D0"). One can install a notify handler using wmi_install_notify_handler("2B814318-4BE8-4707-9D84-A190A859B5D0", handler, NULL). http://lwn.net/Articles/391230 describes how to write an appropriate driver. Found WMI Object, Object ID AB, GUID: 05901221-D566-11D1-B2F0-00A0C9062910, Instance 0x01, Flags: 00 Found WMI Method WMBA with GUID: 1F4C91EB-DC5C-460B-951D-C7CB9B4B8D5E, Instance 0x01 Found WMI Object, Object ID BC, GUID: 2D114B49-2DFB-4130-B8FE-4A3C09E75133, Instance 0x7f, Flags: 00 Found WMI Object, Object ID BD, GUID: 988D08E3-68F4-4C35-AF3E-6A1B8106F83C, Instance 0x19, Flags: 00 Found WMI Object, Object ID BE, GUID: 14EA9746-CE1F-4098-A0E0-7045CB4DA745, Instance 0x01, Flags: 00 Found WMI Object, Object ID BF, GUID: 322F2028-0F84-4901-988E-015176049E2D, Instance 0x01, Flags: 00 Found WMI Object, Object ID BG, GUID: 8232DE3D-663D-4327-A8F4-E293ADB9BF05, Instance 0x01, Flags: 00 Found WMI Object, Object ID BH, GUID: 8F1F6436-9F42-42C8-BADC-0E9424F20C9A, Instance 0x00, Flags: 00 Found WMI Object, Object ID BI, GUID: 8F1F6435-9F42-42C8-BADC-0E9424F20C9A, Instance 0x00, Flags: 00 Found WMI Method WMAC with GUID: 7391A661-223A-47DB-A77A-7BE84C60822D, Instance 0x01 Found WMI Object, Object ID BJ, GUID: DF4E63B6-3BBC-4858-9737-C74F82F821F3, Instance 0x05, Flags: 00 ==================================================================================================== Disassemble DSDT to check for _OSI("Linux"). ---------------------------------------------------------------------------------------------------- Test 1 of 1: Disassemble DSDT to check for _OSI("Linux"). This is not strictly a failure mode, it just alerts one that this has been defined in the DSDT and probably should be avoided since the Linux ACPI driver matches onto the Windows _OSI strings { If (_OSI ("Linux")) { Store (0x03E8, OSYS) } If (_OSI ("Windows 2001")) { Store (0x07D1, OSYS) } If (_OSI ("Windows 2001 SP1")) { Store (0x07D1, OSYS) } If (_OSI ("Windows 2001 SP2")) { Store (0x07D2, OSYS) } If (_OSI ("Windows 2006")) { Store (0x07D6, OSYS) } If (LAnd (MPEN, LEqual (OSYS, 0x07D1))) { TRAP (0x01, 0x48) } TRAP (0x03, 0x35) } WARNING: Test 1, DSDT implements a deprecated _OSI("Linux") test. ==================================================================================================== 0 passed, 0 failed, 1 warnings, 0 aborted, 0 skipped, 0 info only. ==================================================================================================== ACPI DSDT Method Semantic Tests. ACPICA Exception AE_AML_INFINITE_LOOP during execution of method COMP Failed to install global event handler. Test 22 of 93: Check _PSR (Power Source). ACPICA Exception AE_AML_INFINITE_LOOP during execution of method COMP WARNING: Test 22, Detected an infinite loop when evaluating method '\_SB_.AC__._PSR'. ADVICE: This may occur because we are emulating the execution in this test environment and cannot handshake with the embedded controller or jump to the BIOS via SMIs. However, the fact that AML code spins forever means that lockup conditions are not being checked for in the AML bytecode. PASSED: Test 22, \_SB_.AC__._PSR correctly acquired and released locks 16 times. Test 35 of 93: Check _TMP (Thermal Zone Current Temp). ACPICA Exception AE_AML_INFINITE_LOOP during execution of method COMP WARNING: Test 35, Detected an infinite loop when evaluating method '\_TZ_.DTSZ._TMP'. ADVICE: This may occur because we are emulating the execution in this test environment and cannot handshake with the embedded controller or jump to the BIOS via SMIs. However, the fact that AML code spins forever means that lockup conditions are not being checked for in the AML bytecode. PASSED: Test 35, \_TZ_.DTSZ._TMP correctly acquired and released locks 14 times. ACPICA Exception AE_AML_INFINITE_LOOP during execution of method COMP WARNING: Test 35, Detected an infinite loop when evaluating method '\_TZ_.CPUZ._TMP'. ADVICE: This may occur because we are emulating the execution in this test environment and cannot handshake with the embedded controller or jump to the BIOS via SMIs. However, the fact that AML code spins forever means that lockup conditions are not being checked for in the AML bytecode. PASSED: Test 35, \_TZ_.CPUZ._TMP correctly acquired and released locks 10 times. ACPICA Exception AE_AML_INFINITE_LOOP during execution of method COMP WARNING: Test 35, Detected an infinite loop when evaluating method '\_TZ_.SKNZ._TMP'. ADVICE: This may occur because we are emulating the execution in this test environment and cannot handshake with the embedded controller or jump to the BIOS via SMIs. However, the fact that AML code spins forever means that lockup conditions are not being checked for in the AML bytecode. PASSED: Test 35, \_TZ_.SKNZ._TMP correctly acquired and released locks 10 times. PASSED: Test 35, _TMP correctly returned sane looking value 0x00000b4c (289.2 degrees K) PASSED: Test 35, \_TZ_.BATZ._TMP correctly acquired and released locks 9 times. PASSED: Test 35, _TMP correctly returned sane looking value 0x00000aac (273.2 degrees K) PASSED: Test 35, \_TZ_.FDTZ._TMP correctly acquired and released locks 7 times. Test 46 of 93: Check _DIS (Disable). FAILED [MEDIUM] MethodShouldReturnNothing: Test 46, \_SB_.PCI0.LPCB.SIO_.COM1._DIS returned values, but was expected to return nothing. Object returned: INTEGER: 0x00000000 ADVICE: This probably won't cause any errors, but it should be fixed as the AML code is not conforming to the expected behaviour as described in the ACPI specification. FAILED [MEDIUM] MethodShouldReturnNothing: Test 46, \_SB_.PCI0.LPCB.SIO_.LPT0._DIS returned values, but was expected to return nothing. Object returned: INTEGER: 0x00000000 ADVICE: This probably won't cause any errors, but it should be fixed as the AML code is not conforming to the expected behaviour as described in the ACPI specification. Test 61 of 93: Check _WAK (System Wake). Test _WAK(1) System Wake, State S1. ACPICA Exception AE_AML_INFINITE_LOOP during execution of method COMP WARNING: Test 61, Detected an infinite loop when evaluating method '\_WAK'. ADVICE: This may occur because we are emulating the execution in this test environment and cannot handshake with the embedded controller or jump to the BIOS via SMIs. However, the fact that AML code spins forever means that lockup conditions are not being checked for in the AML bytecode. Test _WAK(2) System Wake, State S2. ACPICA Exception AE_AML_INFINITE_LOOP during execution of method COMP WARNING: Test 61, Detected an infinite loop when evaluating method '\_WAK'. ADVICE: This may occur because we are emulating the execution in this test environment and cannot handshake with the embedded controller or jump to the BIOS via SMIs. However, the fact that AML code spins forever means that lockup conditions are not being checked for in the AML bytecode. Test _WAK(3) System Wake, State S3. ACPICA Exception AE_AML_INFINITE_LOOP during execution of method COMP WARNING: Test 61, Detected an infinite loop when evaluating method '\_WAK'. ADVICE: This may occur because we are emulating the execution in this test environment and cannot handshake with the embedded controller or jump to the BIOS via SMIs. However, the fact that AML code spins forever means that lockup conditions are not being checked for in the AML bytecode. Test _WAK(4) System Wake, State S4. ACPICA Exception AE_AML_INFINITE_LOOP during execution of method COMP WARNING: Test 61, Detected an infinite loop when evaluating method '\_WAK'. ADVICE: This may occur because we are emulating the execution in this test environment and cannot handshake with the embedded controller or jump to the BIOS via SMIs. However, the fact that AML code spins forever means that lockup conditions are not being checked for in the AML bytecode. Test _WAK(5) System Wake, State S5. ACPICA Exception AE_AML_INFINITE_LOOP during execution of method COMP WARNING: Test 61, Detected an infinite loop when evaluating method '\_WAK'. ADVICE: This may occur because we are emulating the execution in this test environment and cannot handshake with the embedded controller or jump to the BIOS via SMIs. However, the fact that AML code spins forever means that lockup conditions are not being checked for in the AML bytecode. Test 87 of 93: Check _BCL (Query List of Brightness Control Levels Supported). Package has 2 elements: 00: INTEGER: 0x00000000 01: INTEGER: 0x00000000 FAILED [MEDIUM] Method_BCLElementCount: Test 87, Method _BCL should return a package of more than 2 integers, got just 2. Test 88 of 93: Check _BCM (Set Brightness Level). ACPICA Exception AE_AML_PACKAGE_LIMIT during execution of method _BCM FAILED [CRITICAL] AEAMLPackgeLimit: Test 88, Detected error 'Package limit' when evaluating '\_SB_.PCI0.GFX0.DD02._BCM'. ==================================================================================================== ACPI table settings sanity checks. ---------------------------------------------------------------------------------------------------- Test 1 of 1: Check ACPI tables. PASSED: Test 1, Table APIC passed. Table ECDT not present to check. FAILED [MEDIUM] FADT32And64BothDefined: Test 1, FADT 32 bit FIRMWARE_CONTROL is non-zero, and X_FIRMWARE_CONTROL is also non-zero. Section 5.2.9 of the ACPI specification states that if the FIRMWARE_CONTROL is non-zero then X_FIRMWARE_CONTROL must be set to zero. ADVICE: The FADT FIRMWARE_CTRL is a 32 bit pointer that points to the physical memory address of the Firmware ACPI Control Structure (FACS). There is also an extended 64 bit version of this, the X_FIRMWARE_CTRL pointer that also can point to the FACS. Section 5.2.9 of the ACPI specification states that if the X_FIRMWARE_CTRL field contains a non zero value then the FIRMWARE_CTRL field *must* be zero. This error is also detected by the Linux kernel. If FIRMWARE_CTRL and X_FIRMWARE_CTRL are defined, then the kernel just uses the 64 bit version of the pointer. PASSED: Test 1, Table HPET passed. PASSED: Test 1, Table MCFG passed. PASSED: Test 1, Table RSDT passed. PASSED: Test 1, Table RSDP passed. Table SBST not present to check. PASSED: Test 1, Table XSDT passed. ==================================================================================================== Re-assemble DSDT and find syntax errors and warnings. ---------------------------------------------------------------------------------------------------- Test 1 of 2: Disassemble and reassemble DSDT FAILED [HIGH] AMLAssemblerError4043: Test 1, Assembler error in line 2261 Line | AML source ---------------------------------------------------------------------------------------------------- 02258| 0x00000000, // Range Minimum 02259| 0xFEDFFFFF, // Range Maximum 02260| 0x00000000, // Translation Offset 02261| 0x00000000, // Length | ^ | error 4043: Invalid combination of Length and Min/Max fixed flags 02262| ,, _Y0E, AddressRangeMemory, TypeStatic) 02263| DWordMemory (ResourceProducer, PosDecode, MinFixed, MaxFixed, Cacheable, ReadWrite, 02264| 0x00000000, // Granularity ==================================================================================================== ADVICE: (for error #4043): This occurs if the length is zero and just one of the resource MIF/MAF flags are set, or the length is non-zero and resource MIF/MAF flags are both set. These are illegal combinations and need to be fixed. See section 6.4.3.5 Address Space Resource Descriptors of version 4.0a of the ACPI specification for more details. FAILED [HIGH] AMLAssemblerError4050: Test 1, Assembler error in line 2268 Line | AML source ---------------------------------------------------------------------------------------------------- 02265| 0xFEE01000, // Range Minimum 02266| 0xFFFFFFFF, // Range Maximum 02267| 0x00000000, // Translation Offset 02268| 0x011FEFFF, // Length | ^ | error 4050: Length is not equal to fixed Min/Max window 02269| ,, , AddressRangeMemory, TypeStatic) 02270| }) 02271| Method (_CRS, 0, Serialized) ==================================================================================================== ADVICE: (for error #4050): The minimum address is greater than the maximum address. This is illegal. FAILED [HIGH] AMLAssemblerError1104: Test 1, Assembler error in line 8885 Line | AML source ---------------------------------------------------------------------------------------------------- 08882| Method (_DIS, 0, NotSerialized) 08883| { 08884| DSOD (0x02) 08885| Return (0x00) | ^ | warning level 0 1104: Reserved method should not return a value (_DIS) 08886| } 08887| 08888| Method (_SRS, 1, NotSerialized) ==================================================================================================== FAILED [HIGH] AMLAssemblerError1104: Test 1, Assembler error in line 9195 Line | AML source ---------------------------------------------------------------------------------------------------- 09192| Method (_DIS, 0, NotSerialized) 09193| { 09194| DSOD (0x01) 09195| Return (0x00) | ^ | warning level 0 1104: Reserved method should not return a value (_DIS) 09196| } 09197| 09198| Method (_SRS, 1, NotSerialized) ==================================================================================================== FAILED [HIGH] AMLAssemblerError1127: Test 1, Assembler error in line 9242 Line | AML source ---------------------------------------------------------------------------------------------------- 09239| CreateWordField (CRES, \_SB.PCI0.LPCB.SIO.LPT0._CRS._Y21._MAX, MAX2) 09240| CreateByteField (CRES, \_SB.PCI0.LPCB.SIO.LPT0._CRS._Y21._LEN, LEN2) 09241| CreateWordField (CRES, \_SB.PCI0.LPCB.SIO.LPT0._CRS._Y22._INT, IRQ0) 09242| CreateWordField (CRES, \_SB.PCI0.LPCB.SIO.LPT0._CRS._Y23._DMA, DMA0) | ^ | warning level 0 1127: ResourceTag smaller than Field (Tag: 8 bits, Field: 16 bits) 09243| If (RLPD) 09244| { 09245| Store (0x00, Local0) ==================================================================================================== FAILED [HIGH] AMLAssemblerError1128: Test 1, Assembler error in line 18682 Line | AML source ---------------------------------------------------------------------------------------------------- 18679| Store (0x01, Index (DerefOf (Index (Local0, 0x02)), 0x01)) 18680| If (And (WDPE, 0x40)) 18681| { 18682| Wait (\_SB.BEVT, 0x10) | ^ | warning level 0 1128: Result is not used, possible operator timeout will be missed 18683| } 18684| 18685| Store (BRID, Index (DerefOf (Index (Local0, 0x02)), 0x02)) ==================================================================================================== ADVICE: (for warning level 0 #1128): The operation can possibly timeout, and hence the return value indicates an timeout error. However, because the return value is not checked this very probably indicates that the code is buggy. A possible scenario is that a mutex times out and the code attempts to access data in a critical region when it should not. This will lead to undefined behaviour. This should be fixed. Table DSDT (0) reassembly: Found 2 errors, 4 warnings. Test 2 of 2: Disassemble and reassemble SSDT PASSED: Test 2, SSDT (0) reassembly, Found 0 errors, 0 warnings. FAILED [HIGH] AMLAssemblerError1104: Test 2, Assembler error in line 60 Line | AML source ---------------------------------------------------------------------------------------------------- 00057| { 00058| Store (CPDC (Arg0), Local0) 00059| GCAP (Local0) 00060| Return (Local0) | ^ | warning level 0 1104: Reserved method should not return a value (_PDC) 00061| } 00062| 00063| Method (_OSC, 4, NotSerialized) ==================================================================================================== FAILED [HIGH] AMLAssemblerError1104: Test 2, Assembler error in line 174 Line | AML source ---------------------------------------------------------------------------------------------------- 00171| { 00172| Store (\_PR.CPU0.CPDC (Arg0), Local0) 00173| GCAP (Local0) 00174| Return (Local0) | ^ | warning level 0 1104: Reserved method should not return a value (_PDC) 00175| } 00176| 00177| Method (_OSC, 4, NotSerialized) ==================================================================================================== FAILED [HIGH] AMLAssemblerError1104: Test 2, Assembler error in line 244 Line | AML source ---------------------------------------------------------------------------------------------------- 00241| { 00242| Store (\_PR.CPU0.CPDC (Arg0), Local0) 00243| GCAP (Local0) 00244| Return (Local0) | ^ | warning level 0 1104: Reserved method should not return a value (_PDC) 00245| } 00246| 00247| Method (_OSC, 4, NotSerialized) ==================================================================================================== FAILED [HIGH] AMLAssemblerError1104: Test 2, Assembler error in line 290 Line | AML source ---------------------------------------------------------------------------------------------------- 00287| { 00288| Store (\_PR.CPU0.CPDC (Arg0), Local0) 00289| GCAP (Local0) 00290| Return (Local0) | ^ | warning level 0 1104: Reserved method should not return a value (_PDC) 00291| } 00292| 00293| Method (_OSC, 4, NotSerialized) ==================================================================================================== Table SSDT (1) reassembly: Found 0 errors, 4 warnings. PASSED: Test 2, SSDT (2) reassembly, Found 0 errors, 0 warnings. PASSED: Test 2, SSDT (3) reassembly, Found 0 errors, 0 warnings. ==================================================================================================== 3 passed, 10 failed, 0 warnings, 0 aborted, 0 skipped, 0 info only. ==================================================================================================== Critical failures: 1 method test, at 1 log line: 1449: Detected error 'Package limit' when evaluating '\_SB_.PCI0.GFX0.DD02._BCM'. High failures: 11 klog test, at 1 log line: 121: HIGH Kernel message: [ 3.512783] ACPI Error: Method parse/execution failed [\_SB_.PCI0.GFX0._DOD] (Node f7425858), AE_AML_PACKAGE_LIMIT (20110623/psparse-536) syntaxcheck test, at 1 log line: 1668: Assembler error in line 2261 syntaxcheck test, at 1 log line: 1687: Assembler error in line 2268 syntaxcheck test, at 1 log line: 1703: Assembler error in line 8885 syntaxcheck test, at 1 log line: 1716: Assembler error in line 9195 syntaxcheck test, at 1 log line: 1729: Assembler error in line 9242 syntaxcheck test, at 1 log line: 1742: Assembler error in line 18682 syntaxcheck test, at 1 log line: 1766: Assembler error in line 60 syntaxcheck test, at 1 log line: 1779: Assembler error in line 174 syntaxcheck test, at 1 log line: 1792: Assembler error in line 244 syntaxcheck test, at 1 log line: 1805: Assembler error in line 290 Medium failures: 9 mtrr test, at 1 log line: 76: Memory range 0xc0000000 to 0xdfffffff (PCI Bus 0000:00) has incorrect attribute Write-Combining. mtrr test, at 1 log line: 78: Memory range 0xfee01000 to 0xffffffff (PCI Bus 0000:00) has incorrect attribute Write-Protect. msr test, at 1 log line: 165: MSR SYSENTER_ESP (0x175) has 1 inconsistent values across 2 CPUs for (shift: 0 mask: 0xffffffffffffffff). msr test, at 1 log line: 173: MSR MISC_ENABLE (0x1a0) has 1 inconsistent values across 2 CPUs for (shift: 0 mask: 0x400c51889). wmi test, at 1 log line: 528: GUID 2B814318-4BE8-4707-9D84-A190A859B5D0 is unknown to the kernel, a driver may need to be implemented for this GUID. method test, at 1 log line: 1002: \_SB_.PCI0.LPCB.SIO_.COM1._DIS returned values, but was expected to return nothing. method test, at 1 log line: 1011: \_SB_.PCI0.LPCB.SIO_.LPT0._DIS returned values, but was expected to return nothing. method test, at 1 log line: 1443: Method _BCL should return a package of more than 2 integers, got just 2. acpitables test, at 1 log line: 1643: FADT 32 bit FIRMWARE_CONTROL is non-zero, and X_FIRMWARE_CONTROL is also non-zero. Se

    Read the article

  • What's the difference between View Criteria and Where clause?

    - by frank.nimphius
    Normal 0 false false false EN-US X-NONE X-NONE /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0in 5.4pt 0in 5.4pt; mso-para-margin:0in; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:10.0pt; font-family:"Times New Roman","serif";} A View Criteria is a filter that you apply programmatically or by definition to a View Object instance. It augments the WHERE clause in a View Object query. Named View Criteria are defined in the Query panel of the View Object and are used ·         In combination with the af:query component to build search forms. To do this, you drag and drop the View Criteria from the Named View Criteria node of the View Object in the Data Controls Panel. In the context menu, you then select the Query component - optionally with a result table ·         To restrict a View Object instance in the Application Module model. For this, select a View object instance in the right hand list of the ADF Business Component Data Model panel. Use the Edit button to add a View Criteria to the View Object instance. This ensures that the View Object instance also runs with a query filter applied. View Criteria use bind variables for query conditions that you want to pass in dynamically at runtime. Beside of the ability to apply View Criteria declaratively, you can apply them programmatically in Java. A WHERE clause, if added to a View Object query by design restricts all instances of this View Object, which usually is not what developers want. Because of the benefits - and the configuration options not explained above but in the product documentation referenced below - the recommendation is to use View Criteria. The product documentation explains View Criteria in chapter 5 of the Developer Guide: http://download.oracle.com/docs/cd/E15523_01/web.1111/b31974/bcquerying.htm#BCGIFHHF

    Read the article

  • Can frequent state changes decrease rendering performance?

    - by Miro
    Can frequent texture and shader binding decrease rendering performance? "Frequent" binding example: for object for material in object render part of object using that material "Low count" binding example: for material for object in material render part of object using that material I'm planning to use an octree later and with this "low count" method of rendering it can drastically increase memory consumption. So is it good idea?

    Read the article

  • How can I clear explosions in my function?

    - by hustlerinc
    Hi I have a function to place bombs, and a for loop that places explosions on the tiles where possible. My problem is that I can't remove the explosions after a while. I've tried everything I can come up with so now I turn here as a last resort. The function looks like this: function Bomb(){ var placebomb = false; if(placeBomb && player.bombs != 0){ map[player.Y][player.X].object = 2; var bombX = player.X; var bombY = player.Y; placeBomb = false; player.bombs--; setTimeout(explode, 3000); } function explode(){ var explodeNorth = true; var explodeEast = true; var explodeSouth = true; var explodeWest = true; map[bombY][bombX].explosion = 1; delete map[bombY][bombX].object; for(i=0;i<=player.bombRadius;i++){ if(explodeNorth && map[bombY-i][bombX]){ if(!map[bombY-i][bombX].wall){ if(!map[bombY-i][bombX].object){ map[bombY-i][bombX].explosion = 1; } else var explodeNorth = false; delete map[bombY-i][bombX].object; map[bombY-i][bombX].explosion = 1; } else var explodeNorth = false; } if(explodeEast && map[bombY][bombX+i]){ if(!map[bombY][bombX+i].wall){ if(!map[bombY][bombX+i].object){ map[bombY][bombX+i].explosion = 1; } else var explodeEast = false; delete map[bombY][bombX+i].object; map[bombY][bombX+i].explosion = 1; } else var explodeEast = false; } if(explodeSouth && map[bombY+i][bombX]){ if(!map[bombY+i][bombX].wall){ if(!map[bombY+i][bombX].object){ map[bombY+i][bombX].explosion = 1; } else var explodeSouth = false; delete map[bombY+i][bombX].object; map[bombY+i][bombX].explosion = 1; } else var explodeSouth = false; } if(explodeWest && map[bombY][bombX-i]){ if(!map[bombY][bombX-i].wall){ if(!map[bombY][bombX-i].object){ map[bombY][bombX-i].explosion = 1; } else var explodeWest = false; delete map[bombY][bombX-i].object; map[bombY][bombX-i].explosion = 1; } else var explodeWest = false; } } player.bombs++; } } If anyone can think of a good way to remove the explosion after a delay please help.

    Read the article

  • User intentions analysis

    - by Mark Bramnik
    I'm going to work on some project that would do a user-action recognition based on what he/she does in the system. As far as I understand there are two main parts here: Intercept the user actions (say http traffic in web/ui interaction in thick-client) analysis of user intentions. While the first part is rather technical and therefor easy to implement, the second one is AI related and can be academic. So I was wondering whether someone knows some third-parties/academic projects that would implement the 'action-recognition' stuff?

    Read the article

  • AutoMapper

    AutoMapper is an object-object mapper which allows you to solve issues with mapping the same properties from one object of one type to another object of another type. For example, mapping a heavy entity Customer object to the CustomerDTO could be done with AutoMapper automatically.

    Read the article

  • ASP NET MVC : "Cannot order by type 'System.Object'."

    - by rah.deex
    This is my code. I got this sample from the Internet and I tried to modify it. private void FillGridData() { //IQueryable<SVC> query = _customerService.GetQueryable(); _dataContext = new dbServiceModelDataContext(); var query = from m in _dataContext.SVCs select m; query = AddQuerySearchCriteria(query, _grid.SearchForm); int totalRows = query.Count(); _grid.Pager.Init(totalRows); if (totalRows == 0) { _grid.Data = new List<SVC>(); return; } query = AddQuerySorting(query, _grid.Sorter); query = AddQueryPaging(query, _grid.Pager); List<SVC> customers = query.ToList(); //***ERROR IN HERE***// _grid.Data = customers; } The error says "Cannot order by type 'System.Object'.", what is the matter? Do you have solution for me? This is The AddQuerySorting Method THE PROBLEM IS IN HERE is there anything wrong about the code? :( private IQueryable<SVC> AddQuerySorting(IQueryable<SVC> query, Sorter sorter) { if (String.IsNullOrEmpty(sorter.SortField)) return query; //Used approach from http://www.singingeels.com/Articles/Self_Sorting_GridView_with_LINQ_Expression_Trees.aspx //instead of a long switch statement var param = Expression.Parameter(typeof(SVC), "customer"); var sortExpression = Expression.Lambda<Func<SVC, object>> (Expression.Convert(Expression.Property(param, sorter.SortField), typeof(object)), param); if (sorter.SortDirection == SortDirection.Asc) query = query.OrderBy(sortExpression); else query = query.OrderByDescending(sortExpression); return query; } here is AddQueryPaging Method private IQueryable<SVC> AddQueryPaging(IQueryable<SVC> query, Pager pager) { if (pager.TotalPages == 0) return query; query = query.Skip((pager.CurrentPage - 1) * pager.PageSize) .Take(pager.PageSize); return query; }

    Read the article

  • Embedding a flash object old SWF markup? Will this work??

    - by user342391
    I am embedding a flash object into my site and when I do I get a message from dreamweaver saying "This page contains some swf objects that may not work correctly in the most recent versions of Internet Explorer. Dreamweaver cannot convert them to the new SWF markups please delete each of them and insert them again" I am not aware of any new SWF markups but here is my code to check maybe I am doing something wrong: <!DOCTYPE html PUBLIC "-//W3C//DTD XHTML 1.0 Transitional//EN" "http://www.w3.org/TR/xhtml1/DTD/xhtml1-transitional.dtd"> <html xmlns="http://www.w3.org/1999/xhtml" xml:lang="en" lang="en"> <head> </head> <body> <object classid="clsid:D27CDB6E-AE6D-11cf-96B8-444553540000" codebase="http://download.macromedia.com/pub/shockwave/cabs/flash/swflash.cab#version=9,0,28,0" width="350" height="140" title="Flash Audio Recorder"> <param name="movie" value="AudioRecorder.swf" /> <param name="allowScriptAccess" value="sameDomain" /> <param name="quality" value="high" /> <param name="FlashVars" value="userid=2&settings=myXML/settings.xml" /> <embed src="AudioRecorder.swf" FlashVars="userid=2&settings=myXML/settings.xml" allowScriptAccess="sameDomain" quality="high" pluginspage="http://www.adobe.com/shockwave/download/download.cgi?P1_Prod_Version=ShockwaveFlash" type="application/x-shockwave-flash" width="350" height="140"></embed> </object> </body> </html>

    Read the article

  • What is the correct way to synchronize a shared, static object in Java?

    - by johnrock
    This is a question concerning what is the proper way to synchronize a shared object in java. One caveat is that the object that I want to share must be accessed from static methods. My question is, If I synchronize on a static field, does that lock the class the field belongs to similar to the way a synchronized static method would? Or, will this only lock the field itself? In my specific example I am asking: Will calling PayloadService.getPayload() or PayloadService.setPayload() lock PayloadService.payload? Or will it lock the entire PayloadService class? public class PayloadService extends Service { private static PayloadDTO payload = new PayloadDTO(); public static void setPayload(PayloadDTO payload){ synchronized(PayloadService.payload){ PayloadService.payload = payload; } } public static PayloadDTO getPayload() { synchronized(PayloadService.payload){ return PayloadService.payload ; } } ... Is this a correct/acceptable approach ? In my example the PayloadService is a separate thread, updating the payload object at regular intervals - other threads need to call PayloadService.getPayload() at random intervals to get the latest data and I need to make sure that they don't lock the PayloadService from carrying out its timer task

    Read the article

  • What could be causing a "Cannot access a disposed object" error in WCF?

    - by Nima
    I am using the following code: private WSHttpBinding ws; private EndpointAddress Srv_Login_EndPoint; private ChannelFactory<Srv_Login.Srv_ILogin> Srv_LoginChannelFactory; private Srv_Login.Srv_ILogin LoginService; The Login is my constructor: public Login() { InitializeComponent(); ws = new WSHttpBinding(); Srv_Login_EndPoint = new EndpointAddress("http://localhost:2687/Srv_Login.svc"); Srv_LoginChannelFactory = new ChannelFactory<Srv_Login.Srv_ILogin>(ws, Srv_Login_EndPoint); } And I'm using service this way: private void btnEnter_Click(object sender, EventArgs e) { try { LoginService = Srv_LoginChannelFactory.CreateChannel(); Srv_Login.LoginResult res = new Srv_Login.LoginResult(); res = LoginService.IsAuthenticated(txtUserName.Text.Trim(), txtPassword.Text.Trim()); if (res.Status == true) { int Id = int.Parse(res.Result.ToString()); } else { lblMessage.Text = "Not Enter"; } } catch (Exception ex) { MessageBox.Show(ex.Message); } finally { Srv_LoginChannelFactory.Close(); } } When the user enters a valid username and password, everything is fine. When the user enters a wrong username and password, the first try correctly displays a "Not Enter" message, but on the second try, the user sees this message: {System.ObjectDisposedException: Cannot access a disposed object. Object name: 'System.ServiceModel.ChannelFactory`1[Test_Poosesh.Srv_Login.Srv_ILogin]'. at System.ServiceModel.Channels.CommunicationObject.ThrowIfDisposed() at System.ServiceModel.ChannelFactory.EnsureOpened() at System.ServiceModel.ChannelFactory`1.CreateChannel(EndpointAddress address, Uri via) at System.ServiceModel.ChannelFactory`1.CreateChannel() How can I fix my code to prevent this error from occurring?

    Read the article

  • How to map IDictionary<string, object> in Fluent NHibernate?

    - by user298221
    I am looking to persist user preferences into a collection of name value pairs, where the value may be an int, bool, or string. There are a few ways to skin this cat, but the most convenient method I can think of is something like this: public class User { public virtual IDictionary<string, object> Preferences { get; set; } } with its usage as: user.Preferences["preference1"] = "some value"; user.Preferences["preference2"] = 10; user.Preferences["preference3"] = true; var pref = (int)user.Preferences["preference2"]; I'm not sure how to map this in Fluent NHibernate, though I do think it is possible. Generally, you would map a simpler Dictionary<string, string> as: HasMany(x => x.Preferences) .Table("Preferences") .AsMap("preferenceName") .Element("preferenceValue"); But with a type of 'object', NHibernate doesn't know how to deal with it. I imagine a custom UserType could be created that breaks an 'object' down to a string representing its Type and a string representing the value. We would have a table that looks kind of like this: Table Preferences userId (int) preferenceName (varchar) preferenceValue (varchar) preferenceValueType (varchar) and the hibernate mapping would like this: <map name="Preferences" table="Preferences"> <key column="userId"></key> <index column="preferenceName" type="String" /> <element type="ObjectAsStringUserType, Assembly"> <column name="preferenceValue" /> <column name="preferenceValueType"/> </element> </map> I'm not sure how you would map this in Fluent NHibernate. Maybe there's a better way to do this, or maybe I should just suck it up and use IDictionary<string, string>. Any ideas?

    Read the article

  • Should a Perl constructor return an undef or a "invalid" object?

    - by DVK
    Question: What is considered to be "Best practice" - and why - of handling errors in a constructor?. "Best Practice" can be a quote from Schwartz, or 50% of CPAN modules use it, etc...; but I'm happy with well reasoned opinion from anyone even if it explains why the common best practice is not really the best approach. As far as my own view of the topic (informed by software development in Perl for many years), I have seen three main approaches to error handling in a perl module (listed from best to worst in my opinion): Construct an object, set an invalid flag (usually "is_valid" method). Often coupled with setting error message via your class's error handling. Pros: Allows for standard (compared to other method calls) error handling as it allows to use $obj->errors() type calls after a bad constructor just like after any other method call. Allows for additional info to be passed (e.g. 1 error, warnings, etc...) Allows for lightweight "redo"/"fixme" functionality, In other words, if the object that is constructed is very heavy, with many complex attributes that are 100% always OK, and the only reason it is not valid is because someone entered an incorrect date, you can simply do "$obj->setDate()" instead of the overhead of re-executing entire constructor again. This pattern is not always needed, but can be enormously useful in the right design. Cons: None that I'm aware of. Return "undef". Cons: Can not achieve any of the Pros of the first solution (per-object error messages outside of global variables and lightweight "fixme" capability for heavy objects). Die inside the constructor. Outside of some very narrow edge cases, I personally consider this an awful choice for too many reasons to list on the margins of this question. UPDATE: Just to be clear, I consider the (otherwise very worthy and a great design) solution of having very simple constructor that can't fail at all and a heavy initializer method where all the error checking occurs to be merely a subset of either case #1 (if initializer sets error flags) or case #3 (if initializer dies) for the purposes of this question. Obviously, choosing such a design, you automatically reject option #2.

    Read the article

  • How to dispatch a new property value in an object to the same property of two other objects

    - by WPFadvocate
    In WPF, I've three objects exposing the same DependencyProperty (let's say it's an integer). I want all three property values to remain synchronized, i.e. that whenever the int value changes in an object, this value is propagated to the two other objects. I think of multibinding to do the job, but I don't know how to detect which object changed, thus which value should be used and propagated to the other objects. Edited: here is my tentative code for multibinding, with the false hope that it would work without additional code: // create the multibinding MultiBinding mb = new MultiBinding() { Mode = BindingMode.TwoWay, UpdateSourceTrigger = UpdateSourceTrigger.PropertyChanged }; // create individual bindings to associate object_2 and object_3 to object_1 Binding b2 = new Binding() { Source = object_2, Path = new PropertyPath("X") }; Binding b3 = new Binding() { Source = object_3, Path = new PropertyPath("X") }; // add individual bindings to multibinding mb.Bindings.Add(b2); mb.Bindings.Add(b3); // bind object_2 and _3 to object_1 BindingOperations.SetBinding(object_1, TypeObject_1.XProperty, mb); But actually, there is a runtime error, saying the binding set by the last instruction is lacking a converter. But again I don't know how to write this converter (there is nothing to convert (as this is the case in the related MS sample of code linking 3 rgb properties to a color property), only to forward the value of the property changed to the two other properties). I understand I could solve the problem by creating an X_Changed event in the 3 types and then have each object registering to the two other objects event. I don't like this "manual" way and would prefer to bind the 3 properties together.

    Read the article

  • How can I get the Hibernate Configuration object from Spring?

    - by Wayne Russell
    Hi, I am trying to obtain Spring-defined Hibernate Configuration and SessionFactory objects in my non-Spring code. The following is the definition in my applicationContext.xml file: Code: <bean id="sessionFactory" class="org.springframework.orm.hibernate3.LocalSessionFactoryBean"> <property name="hibernateProperties"> <props> <prop key="hibernate.dialect">org.hibernate.dialect.MySQLDialect</prop> <prop key="hibernate.show_sql">true</prop> <prop key="hibernate.hbm2ddl.auto">update</prop> <prop key="hibernate.cglib.use_reflection_optimizer">true</prop> <prop key="hibernate.cache.provider_class">org.hibernate.cache.HashtableCacheProvider</prop> </props> </property> <property name="dataSource"> <ref bean="dataSource"/> </property> </bean> If I now call getBean("sessionFactory"), I am returned a $Proxy0 object which appears to be a proxy for the Hibernate SessionFactory object. But that isn't what I want - I need the LocalSessionFactoryBean itself because I need access to the Configuration as well as the SessionFactory. The reason I need the Configuration object is that our framework is able to use Hibernate's dynamic model to automatically insert mappings at runtime; this requires that we change the Configuration and rebuild the SessionFactory. Really, all we're trying to do is obtain the Hibernate config that already exists in Spring so that those of our customers that already have that information in Spring don't need to duplicate it into a hibernate.cfg.xml file in order to use our Hibernate features.

    Read the article

  • How to use CodeDomSerializer to serialize an object in .Net?

    - by user341127
    I have a class, which is defined as the following: [ToolboxItem(false)] [DesignTimeVisible(false)] [DesignerSerializer("DevExpress.XtraEditors.Design.RepositoryItemCodeDomSerializer, DevExpress.XtraEditors.v10.1.Design", "System.ComponentModel.Design.Serialization.CodeDomSerializer, System.Design")] [Designer("DevExpress.XtraEditors.Design.BaseRepositoryItemDesigner, DevExpress.XtraEditors.v10.1.Design")] [LicenseProvider(typeof(DXEditorLicenseProvider))] public class RepositoryItem : Component, ISupportInitialize, ICustomTypeDescriptor, IImageCollectionHelper {......} I tried the following code to serialize the object of this class. DesignerSerializationManager m = new System.ComponentModel.Design.Serialization.DesignerSerializationManager(); m.CreateSession(); DevExpress.XtraEditors.Design.RepositoryItemCodeDomSerializer s = m.GetSerializer(typeof(RepositoryItem), typeof(DevExpress.XtraEditors.Design.RepositoryItemCodeDomSerializer)) as DevExpress.XtraEditors.Design.RepositoryItemCodeDomSerializer; RepositoryItem i = persistentRepository1.Items[0]; //m.Container.Add(i); s.Serialize(m,i );// An error "Object reference not set to an instance of an object." happended here. For I am not familiar with CodeDom, I have spent one day to get the way out. I guess the above code has some stupid mistakes. Please give me a hand to show how to serialize AND DeSelialize such objects of the class of Repository. BTW, the reason I don't use any other serializer is that I am supposed not to have rights to know the source code of RepositoryItem and others could inherit RepositoryItem at the same time. And actually I have to deal with RepositoryItem and its descendants. Thank you in advance. Ying

    Read the article

  • PHP5 : Applying a method from an extended class on an object from the original (parent) class.

    - by Glauber Rocha
    Hello, I'm trying to extend two native PHP5 classes (DOMDocument and DOMNode) to implement 2 methods (selectNodes and selectSingleNode) in order to make XPath queries easier. I thought it would be rather straighforward, but I'm stuck in a problem which I think is an OOP beginner's issue. class nDOMDocument extends DOMDocument { public function selectNodes($xpath){ $oxpath = new DOMXPath($this); return $oxpath->query($xpath); } public function selectSingleNode($xpath){ return $this->selectNodes($xpath)->item(0); } } Then I tried to do extend DOMNode to implement the same methods so I can perform an XPath query directly on a node: class nDOMNode extends DOMNode { public function selectNodes($xpath){ $oxpath = new DOMXPath($this->ownerDocument,$this); return $oxpath->query($xpath); } public function selectSingleNode($xpath){ return $this->selectNodes($xpath)->item(0); } } Now if I execute the following code (on an arbitrary XMLDocument): $xmlDoc = new nDOMDocument; $xmlDoc->loadXML(...some XML...); $node1 = $xmlDoc->selectSingleNode("//item[@id=2]"); $node2 = $node1->selectSingleNode("firstname"); The third line works and returns a DOMNode object $node1. However, the fourth line doesn't work because the selectSingleNode method belongs to the nDOMNode class, not DOMNode. So my question: is there a way at some point to "transform" the returned DOMNode object into a nDOMNode object? I feel I'm missing some essential point here and I'd greatly appreciate your help. (Sorry, this is a restatement of my question http://stackoverflow.com/questions/2573820/)

    Read the article

  • How to synchronize placing an object in JNDI across processes?

    - by indra
    I am trying to place an object in JNDI, so that only one of the progam should be able to place it in JNDI. is there any global lock that can be used in J2EE environment. Is RMI can be used for this purpose? please provide any reference links. Thanks in advance. Also, what is NameAlreadyBoundexception? I am trying to use it as a method to synchronize, i.e, only one program places it in JNDI and if other trying to bind should get that exception. But when i am testing the multiple binding I am not getting the Exception.And second binding is done. look up is giving the second object bound. here is my code: private static String JNDI_NAME = "java:comp/env/test/something"; public class TestJNDI { private static String JNDI_NAME = "java:comp/env/test/something"; public static void main(String[] args) throws NamingException { Hashtable env = new Hashtable(); env.put(Context.INITIAL_CONTEXT_FACTORY,"weblogic.jndi.WLInitialContextFactory"); env.put(Context.PROVIDER_URL,"t3://127.0.0.1:7001"); Context ctx = new InitialContext(env); System.out.println("Initial Context created"); String obj1 = "obj1"; String obj2 = "obj2"; try{ ctx.bind(JNDI_NAME, obj1); System.out.println("Bind Sucess"); }catch(NameAlreadyBoundException ne ){ // already bound System.out.println("Name already bound"); } ctx.close(); Context ctx2 = new InitialContext(env); try{ // Second binding to the same name not giving the Exception?? ctx2.bind(JNDI_NAME, obj2); System.out.println("Re Bind Sucess"); }catch(NameAlreadyBoundException ne ){ // already bound System.out.println("Name already bound"); } String lookedUp = (String) ctx2.lookup(JNDI_NAME); System.out.println("LookedUp Object"+lookedUp); ctx2.close(); } }

    Read the article

  • How do I get the inserted id (or object) after an insert with the FormView/ObjectDataSource controls

    - by drs9222
    I have a series of classes that loosely fit the following pattern: public class CustomerInfo { public int Id {get; set;} public string Name {get; set;} } public class CustomerTable { public bool Insert(CustomerInfo info) { /*...*/ } public bool Update(CustomerInfo info) { /*...*/ } public CustomerInfo Get(int id) { /*...*/ } /*...*/ } After a successful insert the Insert method will set the Id property of the CustomerInfo object that was passed in. I've used these classes in several places and would prefer to altering them. Now I'm experimenting with writing an ASP.NET page for inserting and updating the records. I'm currently using the ObjectDataSource and FormView controls: <asp:ObjectDataSource TypeName="CustomerTable" DataObjectTypeName="CustomerInfo" InsertMethod="Insert" UpdateMethod="Update" SelectMethod="Get" /> I can successfully Insert and Update records. I would like to switch the FormView's mode from Insert to Edit after a successful insert. My first attempt was to switch the mode in the ItemInserted event. This of course did not work. I was using a QueryStringParameter for the id which of course wan't set when inserting. So, I switched to manually populating the InputParameters during the ObjectDataSource's Selecting event. The problem with this is I need to know the id of the newly inserted record which I can't find a good way to get. I understand that I can access the Insert method's return value, and out parameters in the ItemInserted event of course my method doesn't return the id using any of these methods. I can't find anyway to access the id or the CustomerInfo object that was inserted after the insert completes. The best I've been able to do is to save the CustomerInfo object in the ObjectDataSource's Inserting event. This feels like an odd way to do this. I figure that there must be a better way to do this and I'll kick myself when I see it. Any ideas?

    Read the article

< Previous Page | 207 208 209 210 211 212 213 214 215 216 217 218  | Next Page >