  • How do I find the cause for a huge difference in performance between two identical Ubuntu servers?

    - by the.duckman
    I am running two Dell R410 servers in the same rack of a data center. Both have the same hardware configuration, run Ubuntu 10.4, have the same packages installed and run the same Java web servers. No other load. One of them is 20-30% faster than the other, very consistently. I used dstat to figure out, if there are more context switches, IO, swapping or anything, but I see no reason for the difference. With the same workload, (no swapping, virtually no IO), the cpu usage and load is higher on one server. So the difference appears to be mainly CPU bound, but while a simple cpu benchmark using sysbench (with all other load turned off) did yield a difference, it was only 6%. So maybe it is not only CPU but also memory performance. I tried to figure out if the BIOS settings differ in some parameter, did a dump using dmidecode, but that yielded no difference. I compared /proc/cpuinfo, no difference. I compared the output of cpufreq-info, no difference. I am lost. What can I do, to figure out, what is going on?

    Read the article

  • Curious enigma of a network cable / connection / quality

    - by Foo Bar
    So, the situation is like this: I'm renting an apartment in a large house and I'm sharing internet with the landlord who lives downstairs. The internet is (in my best guess) optical 20/20Mbit. I don't know how it's all wired in his flat (haven't been there / seen it). Anyway, in my flat comes a cable which seems to be connected directly to the optic to ethernet router (and the password is the default one, so I have access, he he). There was a switch connected to that and to wires that go around the flat, and the wiring is terrible. It's even mixing phone and ethernet, and from what I see some cables are even interconnected!? Anyways, this cable that comes to my flat is very short. I can barely connect my computer on it, but if I do, I seem to get decent speed / performance. Not great, but decent. If, however, I connect switch to it (tried 2 different switches and a wifi switch) it's all blinking but I can't even connect to 192.168.1.1 (the router). DHCP fails, ping is losing 80-100% of replies. So I connected this cable directly to the other cable which goes to my work room, with a connector that has two female jacks and no electronics. Now when I connect my computer in my room, again, the performance is decent. When I connect WRT54GL (with tomato, DHCP disabled) to it and I plug a cable in this WRT and to my computer... the performance is gone. Download seems okay on Speedtest, but upload is .2Mbps and it's connecting forever. So what kind cable troll am I having here? Any ideas?

    Read the article

  • Strange File-Server I/O Spikes - What Is Causing This?

    - by CruftRemover
    I am currently having a problem with a small Linux server that is providing file-sharing services to four Windows 7 32-bit clients. The server is an AMD PhenomX3 with two Western Digital 10EADS (1TB) drives, attached to a Gigabyte GA-MA770T-UD3 mainboard and running Ubuntu Server 10.04.1 LTS. The client machines are taking an extremely long time to access/transfer data on the file server. Applications often become non-responsive while trying to open files located remotely, or one program attempting to open a file but having to wait will prevent other software from accessing network resources at all. Other examples include one image taking 20 seconds or more to open, and in one instance a user waited 110 seconds for Microsoft Word 2007 to save a document. I had initially thought the problem was network-related, but this appears not to be the case. All cables and switches have been tested (one cable was replaced) for verification. This was additionally confirmed when closing down all client machines and rebooting the server resulted in the hard-drive light staying on solid during the startup process. For the first 15 minutes during boot, logon and after logging on (with no client machines attached), the system displayed a load average of 4 or higher. Symptoms included waiting several minutes for the logon prompt to appear, and then several minutes for the password prompt to appear after typing in a user name. After logon, it also took upwards of 45 seconds for the 'smartctl' man page to appear after the command 'man smartctl' was issued. After 15 minutes of this behaviour, the load average dropped to around 0.02 and the machine behaved normally. I have also considered that the problem is hard-drive-related, however diagnostic programs reveal no drive problems. Western Digital DLG, Spinrite and SMARTUDM show no abnormal characteristics - the drives are in perfect health as far as the hardware is concerned. I have thus far been completely unable to track down the cause of this problem, so any help is greatly appreciated. Requested Information: Output of 'free' hxxp://pastebin.com/mfsJS8HS (stupid spam filter) The command 'hdparm -d /dev/sda1' reports: HDIO_GET_DMA failed: Inappropriate ioctl for device (the BIOS is set to AHCI - I probably should have mentioned that).

    Read the article

  • NAT via iptables and virtual interface

    - by Alex
    I'm trying to implement the following scenario: One VM-host, multiple guest VMs, each one gets its own IP-address (and domain). Our server has only one physical interface, so the intended use is to add virtual interfaces on eth0. To complicate our situation the provider uses port-security on their switches, so I can't run the guest interfaces in bridged mode, because then the switch detects a "spoofed" MAC-address and kills the interface (permanently, forcing me to call the support, which I'm sure will get them a little bit angry the third time ;) ). My first guess was to use iptables and NAT to forward all packages from one virtual interface to another one, but iptables doesn't seem to like virtual interfaces (at least I can't get it to work properly). So my second guess is to use the source IP of the packages to the public interface. Let's assume libvirt creates a virbr0-network with 192.168.100.0/24 and the guest uses 192.168.100.2 as IP-address. This is what I tried to use: iptables -t nat -I PREROUTING --src public_ip_on_eth0:0 -p tcp --dport 80 -j DNAT --to-destination 192.168.100.2:80 That doesn't give me the intended results either (accessing the server times out). Is there a way to do what I'm trying to do, or even to route all traffic to a certain IP on a virtual interface to the VM's device?

    Read the article

  • How to Monitor Network in Medium-Sized Company?

    - by Kyle Lowry
    I work at a medium sized company (100+ employees). An issue that has been cropping up is network performance, internet access in particular. We have about 70 or more computers, a mix of Mac OS X and Windows XP & 7 machines. We have several servers (Exchange server, PC file servers, MS SQL, Blackberry, FTP, Mac server, etc). There are four main switches, a SonicWall firewall, and probably a couple routers in the server room with a dozen or so more scattered around the building. The network structure has grown organically over a number of years; and, as far as I know, there really isn't a monitoring solution in place. When we experience network issues (slow connections, dropped packets, and so on), our general solution is to power cycle some hardware or go around to each employee and ask them if they are uploading/downloading any large files. This is really inefficient and time consuming, and it does not allow us to monitor the network, tackling potential problems proactively. I would like to find a solution that would allow me to monitor network usage company-wide in real time, with detail going down to the individual computer, ideally. Given the hodgepodge of equipment and operating systems, what would be the best way to set up some kind of monitoring solution? Hardware, software, restructuring our network architecture?

    Read the article

  • Limited connections to Ubuntu 12.04 server

    - by Luis M. Valenzuela
    I'm having a weird problem with my server. The server is inside my network, connected to a 3com switch which is connected to the router that handles the internet connection. The main purpose of the server is to host a php application. What's happening is that user 1 to 15 in the private network have no problems connecting to the server, when user 16 tries to connect a time out comes out and is unable to connect to the server. It's not just to the php application, but to any service from the server. When the 15 users are using the application, the server doesn't even answer to ping. I haven't set any special limit in Apache's ini file or MySql and the firewall is being turned off because the server is only to give service to the internal network. Is there a parameter in any of the network's card conf. files that might me causing this ? Or should I suspect from the router's or switches configuration ? UPDATE. Tomorrow, I'm gonna do some test on the server modifying two kernel params in : /etc/sysctl.conf The settings are: net.core.somaxconn which has the limit on simultaneous network connections to the server and kernel.shmmax which controls the amount of memory the system can use for managing connections.

    Read the article

  • How to correctly set GNU Screen to display currently running program in hardstatus

    - by johnny_bgoode
    I posted this question on SuperUser but it's hardly getting any views, so I thought I'd ask here as well. In bash, to display the name of the current program in the GNU Screen hardstatus line takes only two configuration lines. First, tell screen what the end of your prompt normally looks like, and supply a default title for a window when you are sitting at in the shell: shelltitle "$ |bash" Next, place this escape sequence in the PS1 variable, before the characters that normally terminate the prompt '$ ' in this case: \033k\033\\\ This technique works, to a point. The hardstatus window title is updated to the name of the currently running program, and then switches back to the default title shortly after execution is finished. One major problem, however, is that this escape string is not escaped itself, causing line-wrapping problems with commands longer than the initial line. This was annoying, so I set out looking for a solution. Turns out, simply escaping the previous escape sequence corrects line wrapping: [\033k]\[\033\\\] Great! My hardstatus window title still updates to the name of the currently running program, and now my longer commands wrap to the second line correctly. However, with this new escape sequence in my PS1, screen updates the window title to the actual command I am typing, not simply the name of the current program once it is executed. I am wondering, has anyone gotten this working correctly - i.e. line wrapping and proper updating of the hardstatus window title? Thanks!

    Read the article

  • How to correctly set GNU Screen to display currently running program in hardstatus

    - by johnny_bgoode
    In bash, to display the name of the current program in the GNU Screen hardstatus line takes only two configuration lines. First, tell screen what the end of your prompt normally looks like, and supply a default title for a window when you are sitting at in the shell: shelltitle "$ |bash" Next, place this escape sequence in the PS1 variable, before the characters that normally terminate the prompt '$ ' in this case: \033k\033\\ This technique works, to a point. The hardstatus window title is updated to the name of the currently running program, and then switches back to the default title shortly after execution is finished. One major problem, however, is that this escape string is not escaped itself, causing line-wrapping problems with commands longer than the initial line. This was annoying, so I set out looking for a solution. Turns out, simply escaping the previous escape sequence corrects line wrapping: \[\033k\]\[\033\\\] Great! My hardstatus window title still updates to the name of the currently running program, and now my longer commands wrap to the second line correctly. However, with this new escape sequence in my PS1, screen updates the window title to the actual command I am typing, not simply the name of the current program once it is executed. I am wondering, has anyone gotten this working correctly - i.e. line wrapping and proper updating of the hardstatus window title?

    Read the article

  • NTbackup doesn't complete on system state

    - by Joe Majsterski
    I have a Windows 2003 server that is running a semi-custom backup task. The scheduled task calls NTbackup with a few switches depending on whether it is a full or incremental backup. Most of the time, the NTbackup completes fine, and the wrapper then appends the NTbackup log into its own log before adding a few final comments and completing. The problem I am having is that sometimes, NTbackup seems to just... blank out. It always completes backup of the C: and E: drives, but then it will start the system state and not add any more messages into the event log saying it completed that. And the NTbackup log is left empty, since it doesn't write anything to the log until all the backup tasks are complete. This is causing the wrapper to append no text into its own log. That causes problems for us because we read the information out of that log to determine whether backups are failing. The wrapper task also reports that it is completing normally in the event log. Anyone ever seen a case where system state doesn't complete consistently? To be clear, the server is not logging any error messages anywhere. It's just not seeming to complete or log anything.

    Read the article

  • How do I automatically connect my client to an ODBC data source on another machine with dynamic IP?

    - by Kdansky
    At the customer's place, we've got a postgres DB on a server, and a few clients. We connect them through ODBC-drivers, and all machines run windows (usually XP). Now we had a few annoying issues: The client "forgets" some flags in the ODBC drivers, such as ByteA as LO. Every time anything changes, we have to reset that, and type in the password, and sometimes even the IP of the server. On x64 machines running Windows 7, configuring this is a pain as the system settings dialogue will only show 64-bit connections by default. And most importantly: If the server changes IP because the customer restarts or replaces a switch, all connections are lost. Annoyingly, this cannot be fixed with just correcting the IP, but rather, we have to check every single place (even hba_conf) because all the settings magically disappear. Our customers often are very small companies, where "server" means "that one PC in the other room", and not "Oracle mainframe in the dungeon", so we don't want to rely on them not restarting switches. Is there a better way than to rely on these really unstable settings? Are these settings somewhere in a file which I could edit manually, to make fixing it easier?

    Read the article

  • Windows 7 32bit resolution is limited for HDTV monitor

    - by Nick
    I have a small Magnavox HDTV that i am using to test a Frankenstein PC build. The goal is to eventually connect to my old rear projection HDTV which supports 1080i via component input. The goal is also not to buy anymore stuff, otherwise i will just buy a smartTV and be done. I have a ATI Radeon HD 3450 with component out adapter YPrPb. The monitor supports 1080p, but over analog component out, should only go upto 1080i. I have had this working with another setup. On this particular setup, i have Windows 7 32bit, with the latest 12.8 catalyst drivers installed. the windows splash screen starts in 480p, then switches to 480i when the login prompt is shown. When try to change the resolution, 720x480 is the maximum value of the slider. I have also tried the "list all modes" and that also maxes out at 720x480. There are two options for this monitor in the devices seciton, Generic PNP monitor, and Generic non-PNP monitor. Neither setting fixes this. Any ideas on how to get 1080i?

    Read the article

  • nVidia performance with newer X and newer driver abysmal with Compiz

    - by Nakedible
    I recently upgraded Debian to Xorg 2.9.4 and installed nvidia-glx from experimental, version 260.19.21. This was somewhat of an uphill battle as the dependencies for the experimental nvidia-glx package are still somewhat broken. I got it to work without forcing the installation of any packages and without modifying the packages. However, after the upgrade compiz performance has been abysmal. I am using the desktop wall plugin and switching viewports is really slow - takes a few seconds for each switch. In addition to this, every effect that compiz does, such as zoom animations for icons when launching applications, takes seconds. The viewport switching speed changes relative to the amount of windows on that virtual screen - empty screens switch almost at normal speed, single browser windows work almost decently, but just 4 rxvt terminals slows the switches down to a crawl. My compiz configuration should be pretty basic. Xorg is likewise configured without anything special - the only "custom" configuration is forcing the driver name to be "nvidia". I've fiddled around with the nvidia-settings and compizconfig trying different VSync settings, but none of those helped. My graphics card is: NVIDIA GPU NVS 3100M (GT218) at PCI:1:0:0 (GPU-0). This is laptop GPU that is from the Geforce GTX 200 series. Graphics card performance should naturally be no problem. EDIT: In the end, nothing really worked, and I got really annoyed with the state of compiz and its support in Debian. Many nVidia driver revisions have passed and I am using Gnome 3 now, so I am accepting the best answers to this question even though the issue was not resolved.

    Read the article

  • Problems with Net::FTP slowing down

    - by c0bra
    I'm running into an issue with using Net::FTP (latest version 2.77) to transfer files to a remote host where a process is waiting to take the file and feed into some other system. The remote process does this every 5 minutes but ignores files that were modified in the last 0.2 seconds (that's right, 1/5th of a second). The problem is that for some reason the transfer seems to halt or slow down a bit and no data is transferred for several seconds and during this time the process picks up the incomplete file and removes it. The weird thing is that manually using the ftp binary the file seems to transfer fine. I've tried messing with all of the Net::FTP switches (Active/Passive, different Blocksizes) and nothing seems to help. What's also weird is that the file seems to transfer fairly quickly at first and on occasion a bit into the transfer. Like 300-500k will go up immediately, but then it slows down to where the file size is only increasing by 2,896 bytes every several seconds. It doesn't seem to happen when I try sending the file to a different remote host, but since a regular manual ftp transfer works with this host I don't know what to think. Some combination of Net::FTP and possibly a slow or wonky connection?

    Read the article

  • 2 Computers, same network, different outgoing speeds when uploading to internet?

    - by user117339
    I have 2 work machines in my office, a PowerMac G5 and a MacBook Air. Both behind an IPCop firewall. The PowerMac is connected through a gigabit switch, the MacBook Air is connected through a Netgear 802.11g access point that is then plugged into the gigabit switch. There is also a FreeNAS box, both machines are able to read and write files to it at close to their pipe speeds. The main problem is when I am trying to upload files to the internet at large. The G5 is only hitting 0.1 - 0.25 Mbps. The Macbook is able to hit 2-3 Mbps. The setup (G5 / IPCop / Network) has been the same for 5 years. The issues with the internet speed started about 3 months ago. I hadn't tested on the Macbook at this point. I had complained to the ISP, they said their modem needed a firmware update, did that nothing changed. Reset IPCop, turned off squid, etc. No changes. The ISP switched the office over to a better plan with a theoretical 6 Mbps up, still no change. At this point I tried testing the Macbook, and lo and behold there's the speed. But why? I have tried changing out everything, cables, switches, using another ethernet port on the G5, wiping the system, using DHCP, using manual IPs, changing DNS servers, etc. Nothing works. I figured that if there was something horribly wrong with the network, then internally I would find a similar issue, but that is perfect. iperf, ping, etc show no dropped packets and near saturation of the internal network. I'm at a loss as to what the heck is going on. Any ideas would be appreciated! Below are some screenshots of speedtest.net: G5: Macbook Air:

    Read the article

  • Windows mounted network drives slow after upgrading switch

    - by Kver
    On our small business network our old 10/100 consumer grade switch gave up the ghost, and we replaced it with a proper business-grade gigabyte switch. After wiring it in our Linux and Mac users immediately got back to working off of network drives; But 2 of our 3 Windows 7 PCs have suddenly experienced a tremendous slowdown with mapped network drives; Windows will become stuck "discovering" a folder causing applications to freeze when trying to open files. It will instantly display and browse files, but the moment you try to open one the bug hits. To remedy this we have our users copying files to the desktop, but it can take a few minutes while windows is stuck "calculating" the time it will take to copy. These aren't big files, mostly excel sheets less than 500KB - these operations are instant on Linux and Mac. (The third Windows machine is having no issues) I've tried remapping the drives, mapping to different drive letters, rebooting, etc. I'm at a loss, because switches are mostly transparent, and it's only after the switch was replaced that the Windows PCs started acting up. What black-magic voodoo am I missing to make Windows work? Thank you.

    Read the article

  • What causes a switch port to receive data not destined for it?

    - by user1693454
    We are having an intermittent fault which is effecting one of our control systems on one of our HP Procurve switches. For some reason, this PLC (10mbit port - 192.168.6.56) which is attached directly to the HP Switch intermittantly start's receiving data which is not destined for it. The data is being sent from a Thecus NAS with latest firmware (192.168.6.218) to a physical IBM Server running Win2003R2 and SAP (192.168.6.225). The problem does not just send to this server, it has been to other physical servers in the past too, but always from the Thecus NAS. I am using a monitor port to wireshark what is going in/out of the PLC - normally there would be about 1mb in/out per 2 or 3 minutes - only a server asking the state of the coils. When the problem occurs, there is a flood of data being put onto the PLC line - in this captured instance, about 67mb in less than a minute. Due to this, there is no way that the PLC can be queried as the port is effectively DOSed, in turn killing part of our factory. I know that having Production on the same vlan as IT is not a good idea - I agree, however it cannot be changed at the moment (will have to wait 3 months), as well as the problem has only started happening in the last 3 months. Here is a screen cap of one of the packets being sent from the Thecus NAS which was captured from the PLC port on the HP Switch: And there are over 700 of these in this one 1024kb file. If anyone has any idea on what could be going on, some help would be greatly appreciated. If you need to know anything more, let me know! Cheers!

    Read the article

  • Can't get 1440x900 resolution with GRUB2 although vbeinfo says it's available

    - by TomSW
    I'm trying to use GRUB2 in graphical mode with 1440x900 resolution, but the result is always garbled nonsense: the highest resolution I can get is 1280x800. Word is from googling that long as vbeinfo lists a resolution, GRUB2 can use it. This doesn't seem to be true: vbeinfo says that 1440x900 is available but it doesn't work. Testing it from the GRUB2 command line: set gxfmode=1440x900 terminal_output gfxterm # -> garbled nonsense # back to trusty 640x480 terminal_output console The graphics card is an Intel GM965. Once linux boots the framebuffer switches to 1440x900. Added after epheminent's reply and various experiments vbeinfo lists two sets of modes. The first set runs from 0x160 to 0x16b, with resolutions 768x480, 960x600, 1280x800 and 1440x900 Then - after a bunch of text-only modes - the second set, containing resolutions 1024x768, 800x600, and 640x480 The first set of modes aren't altered by 915resolution. They all work except 1440x900. The resolution of modes in the second set can be altered using the 915resolution module / command available in GRUB2 = 1.99. # in /boot/grub/grub.cfg insmod 915resolution # 30, 32, 34 all work for me: all that varies is which modes are altered 915resolution 30 1440 900 # setting an impossible resolution changes the mode to "text-only" # in my case 1280x1024 is not supported 915resolution 30 1280 1024 Clearly, 1440x900 should just work: adding it with 915resolution is just a workaround.

    Read the article

  • Shortcuts that make using Windows easier? [closed]

    - by ekaj
    Over the years I have found out a good bit of shortcuts, all of which make using Windows that much faster and easier. I was wondering if I had missed any important ones, or ones that just saved any time. I tried to keep these relative to Windows only, as programs such as Mozilla, Photoshop, etc. bring in hundreds of other shortcuts, which do not apply to all users. These are the current ones I know: For the mouse: Scroll wheel - opens a link in IE into a new tab - closes a specific tab in IE when closed on Right click-n-drag - nifty menu to make a copy of a file or create a shortcut For the keyboard: Cntrl + Alt + Del - need this be explained? WinKey + R - opens 'Run..' WinKey + D - shows the desktop WinKey + E - opens 'My Computer' WinKey + F - opens 'Find..' WinKey + Tab - cool way to switch inbetween windows WinKey + L - locks the computer Alt + Tab - switches windows with a simple interface Alt + F4 - closes windows Alt + F - opens 'File' (Handy for things like IE if you have the menubar disabled) Cntrl + F - find text on current document Cntrl + W - closes a window, or current active tab in IE (or IE itself if only one tab) Cntrl + C - copies selected text / image Cntrl + V - pastes selected text / image So does anyone know of any more shortcuts that just make life easier? I would be much appreciative of any, and I am sure that some other users would like to know some too =]

    Read the article

  • Having an issue trying to get Gigabit speed across my network (Ubuntu Server)

    - by user94217
    I've just started looking into the network speeds at my office, the entire network is setup to be "Gigabit". This includes Gb switches, Gb Network cards and Cat 5e cabling. I'm not expecting the full speed, I just want more than ~90 Mb/s. I've been running some tests with iperf the linux tools and checking the hardware with ethtool. I have 3 servers and when doing my checks/test I discovered that the two backup servers can access each other at around 450 Mb/s but when using either one of them to connect and test the main server, I only get the 90Mb/s even though ethtool shows the networking card running at 1000/Full. The only difference between all the server/networking cards is the "Port" which ethtool shows. On the two backup servers the "Port" is shown as MII yet on the other it's shown as "Twisted Pair". When using ethtool -s to manually set the "Port" to MII on the main server, it looses all connectivity and does not show "Speed" or "Duplex". Anyway, Am i doing something wrong? Is there a specific reason my main server cannot use Gb when there appears to be no difference except the "Port"?

    Read the article

  • Different subnets routing with just one layer 3 switch

    - by GustavoFSx
    Our current network looks like this: Location 1: 2 Layer 2 switches | subnet 192.168.1.0/24 | Firewall for our VPN Location 2: 1 Layer 2 switch | subnet 192.168.3.0/24 | Firewall for our VPN Location 3: 1 Layer 2 switch | subnet 192.168.5.0/24 | Firewall for our VPN We just got a direct fiber connection between location 1 and 2, we also got a new HP V1910 24G layer 3 switch. I tried to follow the instructions on this site, but I can't get it to work. I think our network should look like this: Location 1: HP Switch FIBER to L2 | subnet 192.168.1.0/24 | Firewall for our VPN Location 2: 1 Layer 2 switch | subnet 192.168.3.0/24 | FIBER to L1 Location 3: 1 Layer 2 switch | subnet 192.168.5.0/24 | Firewall for our VPN So, how can I get routing working on our location 2? It's old gateway was a firewall device on ip 192.168.3.1. I'm thinking on creating a VLAN Interface on 192.168.3.1 on the switch for the Location 2. But how will I handle that on the HP switch that has a direct fiber connection with that switch? Please help, I'm not very good with networking.

    Read the article

  • Graphics card ATI Asus 9250 128 MB AGP problem.Monitor switching off.

    - by Dominick1978
    I have an old system with these specs: Motherboard: Via P4x266a (with AGP 4x) CPU: P4 1,7 Ghz Memory: 1152 MB DDR SDRAM Graphics card: Voodoo 3 2000 16 MB PSU: 300 Watt It also has 1 dvd-rom, 1 dvd-rw, 2 hard drives (all 4 connected via molex) , 1 sounblaster sound card and 1 ethernet card (both connected via pci). OS: XP Pro Recently I bought Asus 9250 128 MB AGP to replace voodoo.Wnen I switch on the pc the initial screens (until after the xp logo) sometimes are distorted with blurred colours.When XP are loaded there is some flickering but the rest are ok.XP can't recognize the card seeing it as just a VGA adapter.I have downloaded the latest xp drivers from ATI website and installed them.Then after the restart everything is ok (no distorted image or blurring) until after the xp logo.After this the monitor turns off while the pc is still running.I have tried many drivers but the problem persists (of course I removed the voodoo drivers before from the display adapter properties).Only once I have managed to enter XP (after changing BIOS features for graphics card from 256 MB to 128 MB) but the drivers on the control panel had an exclamation mark (ati 9250!) and below them ati 9250 secondary without ! under the display adapter tab and the ATI catalyst program said that it couldn;t find the card.That was the opnly time I went beyond the xp logo.Now the monitor auto switcheS off. So, what do you think? 1)Is this a broken card? 2)Is it the drivers of the card? 3)Is it PSU fault? 4)Anything else? Thanks for your help and excuse my english!

    Read the article

  • Can I split one ethernet line coming out of my wall into multiple separate lines?

    - by Burteçin 'Turk' Sapta
    Hi all and thanks in advance. I'll start with some background. I live in an apartment which provides internet service included in the rent. They use company called pavlov for the internet http://pavlovmedia.net/ wireless seems to be working fine but wired connection is at least %30 faster. Ethernet, cat5 outlet is built in the wall, and there is only 1 outlet in each room. I would like to take this 1 outlet coming out the wall and multiply it into 4 wires, for desktop, playstation, tv and laptop without loosing any internet bandwidth. i have absolutely no idea weather this line is coming from a switch or a router but i have been researching Ethernet splitter, routers, switches, hubs and haven't found a solid answer. what is the best solution for me? thank you once again! EDIT: ok this picture cleared few things http://www.home-network-help.com/images/home-network-expanded.jpg so seems that an ethernet switch is to ethernet as a USB hub is to USB. what is really 10/100Mbps Network Switch and what is the cap?

    Read the article

  • windows server 2003 speed issues

    - by farzinSH
    I have a HP server with windows server 2003 and 50 windows XP clients. Since a week and a half the networks speed suddenly drop 2-3 times per day. It gets so slow that none of the clients could work with the HIS program installed on them. We tried so many different things such as replacing the hubs,switches and even some wires. Every time one of these changes solves the problem and the network goes back to its normal state. I checked everything. Even when I disconnected all the clients from the server and connected it to just one computer the problem still remained for 2 hours. I just narrowed down the problem to the couple of likely speculations as follows: viruses? (Updated Kaspersky running on the server shows none) server hardware failure? Physical memory usage on the server? (Because the last time the problem occurred none of the changes above solved the issue so I restarted the server an checked the physical memory usage which was 2 GBs. But I noticed it's increasing over time to over 9 GBs...the server has 16 GBs of RAM.) I surfed the internet and got nothing. Any help would do us a lot....thanks in advance

    Read the article

  • How can I assign DHCP leases from a script?

    - by devicenull
    I have an environment where there is one DHCP server servicing a number of different hosts/vlans. The switches are configured to forward the DHCP requests over (via ip-helper) and include information about the port (option 82). I'd like to take that information and translate it into an actual lease for the server. I don't think it's particularly feasible for me to pregenerate a list of available leases, but I should be able to determine an address for a lease as it comes in. Is there an DHCP server that can execute a script when it receives a request? (Note: I'm looking to assign the IP from the script, not have the DHCP server assign an IP then execute the script) Edit: So, ultimately I'm trying to provide DHCP/PXE services over a large number of distinct vlans. This is so we can do OS installs via PXE booting without having to have a separate PXE vlan. I've got the switch config down no problem, and I have the DHCP server recognizing option 82. I need a way to pull DHCP assignments from another system (this other system would know what subnet to use on what vlan), but I do not want to have to pregenerate a list of vlan:DHCP range pairs.

    Read the article

  • Software disables itself when the PC is accessed via RDP

    - by blckgrffn
    We have a large, specialty printer that has vendor specific software that enables its use outside of it showing up simply as a printer in the Windows Control Panel. This software recognizes when we RDP into the machine and "disconnects" the PC from the printer within its proprietary control panel. All is well when an application like TeamViewer is used to access the machine. Ostensibly, the application is helping us be safe by "enforcing" that the machine used for the printer is a walk up workstation, or so the support folks informed me. If TeamViewer etc, fixes the issue, then what is the problem? We have many headless workstations in our warehouse attached to a variety of specialty machines, all used via RDP. We want/need to keep access to the machines the same for the sanity of our production staff. The meat of the question - how, specifically, might a machine know that it is being accessed via RDP (terminal services management???) and how might this be defeated without altering an application or driver. Of note, the system being used is a Windows 7 Pro machine hooked to the printer via USB. Thanks! Nat edit Is there any combination of /admin switches, etc. that will possibly fix this? Simply putting /admin did not.

    Read the article