  • Moving Portable Office. Have a LAN & Phone line query?

    - by John Smith
    We are about to move a portable office that has 8 phones and 12 lan connections. They are all wired back to our main switch and Nortel bcm200 phone system which are only about 20m (65ft) away. After the move the office will be 180m (600ft) away from these. What is the maximum length of cable a digital phone line can be? I am aware that a lan connection can only be 100m (305ft) when using cat5e utp. Does this rule apply to phone connections also? If so how can I extend beyond 100m for the phones? I was going to install about three cabinets, 3 switches and 6 patch panels for the lan connections but the ideal struck me tonight that maybe I could run a fibre optic line. Would this be feasible? Any feedback on this is greatly appreciated. Thanks

    Read the article

  • Creating a Network link between 2 buildings

    - by Adam
    Hey My company needs to create a network link between two buildings. Currently we have a cat5e network in one building and would like to connect some computers(about 15) in our second building to the main network in the first building. The distance between the two buildings is 30 metres. The 30 metres means going through a wall from the first building. Going through the car park and then through a wall into the other building. We can run any cables through speed ramps and so we do not need to dig up the road! Also the second building does not have an Internet connection and so we have to create some sort of cable link so that they can share our Internet connection. Ideas? Should we just run cat5e? Should we run fibre? Should we run coaxial?

    Read the article

  • Server room kit?

    - by Bill Weiss
    I feel like this is a question I've seen on here before, but some searching didn't do me any good. This looks similar, but I'm looking for stuff I leave there, not what's in my go-bag. What would you say is indispensable equipment in your server room? I've inherited one that's a bit light on stuff (except for servers, those are in there). We're in the single digits of racks, if that matters. I'm thinking of things like: Cable labeler Ethernet tester (copper at least, fibre if you need) ... ? Community wiki, because, really. [Edit] I suppose it's important to say that it's a colo facility, kind of far from the office. No food, water, etc. :(

    Read the article

  • What is Light Peak

    - by Jonathan.
    I've heard this a lot recently, todo with Apple and Intel. Some says it's a protocol, others say it's fibre optic, and others say it's copper. One source even said it was a "wireless wire". Apparently it can carry data, but not video streams, surely the cable can't know the difference between 1s and 0s representing data, and 1s and 0s representing video streams. Or it will replace all the wires we currently have except power, another place said it is for inside laptops. Those are just examples so I haven't given any sources, I just want to know what on Earth Light Peak is?

    Read the article

  • Can a Linksys Router be the cause of bad speeds on a 1.5 mbps link.

    - by gramware
    We use a Linksys 5-port router at a smal organization with about 20 employees. We recently acquired a 1.5 mbps fibre link, but sometimes the link goes down and speeds are still low. On enquirey from the ISP, this was part of the response, However there maybe throttling due to the router in place. A Linksys is a low end router and may be unable to carried traffic of up to 1536Kbps. We are in a position to deploy a Cisco 871 router on test for 2 wks to eliminate that possibility. Also kindly advise the destination of the ping results they look to high. How true is that about the router throttling the network and need for a bigger one.

    Read the article

  • RHEL raw device (over VMware RDM) performance issues

    - by jifa
    I'm running RHEL 5.3 over vSphere 4.0U1. I configured multiple LUNs on my NetApp (Fibre) storage, and added the RDM on two (Linux) VMs, using the Paravirtual SCSI adapter. One LUN is 100GB in size, successfully mapped to /dev/sdb on both VMs, 5 more are 500MB in size (mapped to /dev/sd{c-g}. I also created one partition per device. I have encountered two issues: First, writing directly to /dev/sdb1 gives me ~50MB/s, while any of the /dev/sd{c-g}1 gives me ~9MB/s. There is no difference in configuration of the LUNs apart from their size. I am wondering what causes this but this is not my main problem, as I would settle for 9 MB/s. I created raw devices using udev pretty straightforwardly: ACTION=="add", KERNEL=="sdb1", RUN+="/bin/raw /dev/raw/raw1 %N" per device Writing to any of the new raw devices dramatically slows down performance to just over 900KB/s. Can anyone point me in a helpful direction? Thanks in advance, -- jifa

    Read the article

  • BGP Router reccomendations for simple redundancy [closed]

    - by Jona
    We have two sites that each have an internet connection and have a dedicated dark fibre between them. Each site has it's own IP space and we have an AS number. We're looking to be resilient to failure of the internet connection to either site and so need to buy a pair of approriate routers. Requirements are: Able to run 2 bgp sessions (one with the ISP, one with the other site router) Option to take a full table from the upstream ISPs would be nice. Able to provide HA gateways on the LAN side (e.g. 192.168.0.254 will automatically migrate if it's host router lost power) A dedicated device rather than a server running Linux / BSD Not crazy expensive. Any help / advice much appreciated.

    Read the article

  • How do I improve picture quality while streaming live football (soccer) from my Dell D600 to an HDTV?

    - by Bob
    I have fibre broadband with speeds up to 38mbs, my Dell D600 has its max 2gb ram and has an ATI Mobility RADEON 9000 4xAGP 32mb card in it...Its TV support it says is NTSC or PAL in S-video and composite modes with a 7-pin mini-DIN connector (optional S-video to composite video adapter cable) and a vga port which i am using at the moment... The laptop runs Windows XP, an 80g HD with only windows + necessary updates and anti virus software on it..... There is HDMI on the TV, but not the laptop Fairly slow moving and close up pictures arent too bad, but when the movment is fast(a shot on goal) or in the distance, I cant see the ball and the images go out of focus.

    Read the article

  • Installing WiFi in a church for internet access

    - by Dave Griffiths
    Hi, a colleague at work asked this question: My local church want to get WiFi enabled in the whole of their offices and main church building. The offices and main building are in the same overall structure and so the signal does not need to travel outside to any other buildings outside this main structure. Where would I start on such a project and what kind of repeaters are needed (and how are they set up) given that some of the walls are pretty thick. Do you still have one ADSL line coming in to router or are there some options of having two lines coming in so that they isn't a single point of failure. Am looking at fibre for the broadband for increased speed. Any starting pointers appreciated.

    Read the article

  • Product Update Bulletin: Oracle Solaris Cluster October 2013

    - by uwes
    Announcing new qualifications and general news for the Oracle Solaris Cluster product. Hardware Qualifications Sun Server X4-2 and X4-2L servers, Sun Blade X4-2B server module with Oracle Solaris Cluster 3.3 Sun Storage 16 Gb Fibre Channel ExpressModule Universal HBA, Emulex Oracle Dual Port QDR InfiniBand Adapter M3 Software Qualifications Oracle Database 12c Real Application Cluster with Oracle Solaris Cluster 4.1 Oracle Database 11.2.0.4 single instance and RAC with Oracle Solaris Cluster 4.1 Oracle VM server for SPARC 3.1 SAP Netweaver with new kernel versions ZFS Storage Appliance Kit version 2011.1.7.0 and 2013.1.0.0 Application monitoring in Oracle VM for SPARC failover guest domain Storage Partner Update Oracle Solaris Cluster 3.3 3/13 with the HDS Enterprise Storage arrays EMC SRDF for Oracle database 12c RAC in Oracle Solaris Cluster 4.1 geo cluster configuration Oracle Solaris Cluster References Korea Enterprise Data, HDFC Securities, Dealis Fund Operations Web Updates New blog entry: Oracle Solaris 10 Brand Zone cluster Solaris Application Engineering website now includes Oracle Solaris Cluster application support information Please read the Oracle Solaris Cluster Product Update Bulletin on Oracle HW TRC for more details. (If you are not registered on Oracle HW TRC, click here ... and follow the instructions..) _____________________________________________________________________ For More Information Go To:Oracle.com Oracle Solaris Cluster page Oracle Technology Network Oracle Solaris Cluster pageOracle Solaris Cluster mos communityPartner web Oracle Solaris Cluster pageOracle Solaris Cluster Blog Solaris.us.oracle.com page

    Read the article

  • Modelling work-flow plus interaction with a database - quick and accessible options

    - by cjmUK
    I'm wanting to model a (proposed) manufacturing line, with specific emphasis on interaction with a traceability database. That is, various process engineers have already mapped the manufacturing process - I'm only interested in the various stations along the line that have to talk to the DB. The intended audience is a mixture of project managers, engineers and IT people - the purpose is to identify: points at which the line interacts with the DB (perhaps going so far as indicating the Store Procs called at each point, perhaps even which parameters are passed.) the communication source (PC/Handheld device/PLC) the communication medium (wireless/fibre/copper) control flow (if leak test fails, unit is diverted to repair station) Basically, the model will be used as a focus different groups on outstanding tasks; for example, I'm interested in the DB and any front-end app needed, process engineers need to be thinking about the workflow and liaising with the PLC suppliers, the other IT guys need to make sure we have the hardware and comms in place. Obviously I could just improvise in Visio, but I was wondering if there was a particular modelling technique that might particularly suit my needs or my audience. I'm thinking of a visual model with supporting documentation (as little as possible, as much as is necessary). Clearly, I don't want something that will take me ages to (effectively) learn, nor one that will alienate non-technical members of the project team. So far I've had brief looks at BPMN, EPC Diagrams, standard Flow Diagrams... and I've forgotten most of what I used to know about UML... And I'm not against picking and mixing... as long as it is quick, clear and effective. Conclusion: In the end, I opted for a quasi-workflow/dataflow diagram. I mapped out the parts of the manufacturing process that interact with the traceability DB, and indicated in a significantly-simplified form, the data flows and DB activity. Alongside which, I have a supporting document which outlines each process, the data being transacted for each process (a 'data dictionary' of sorts) and details of hardware and connectivity required. I can't decide whether is a product of genius or a crime against established software development practices, but I do think that is will hit the mark for this particular audience.

    Read the article

  • Dynamic model interactions

    - by Richard
    I am just curious as to how in many games (namely games like arkham asylum/city, manhunt, hitman) do they make it so that your character can "grab" a character in front of you and do stuff to them. I know this may sound very confusing but for an example go to youtube and search "hitman executions", and the first video is an example of what i'm asking. Basically I'm wondering how they make your model dynamically interact with whatever other model you come across, so in hitman when you come up behind some one with the fibre wire you strangle the other character or if you have the anesthetic you come up behind some person and put your hand over there mouth while they struggle and slowly go to the floor where you lay them down. I am confused as to whether it was animated to use two models using specific bone/skeletal identifiers, if it is just two completely separate animations that are played at the correct time to make it look like they are actually interacting or something else all together. I am not an animator so i assume most of what i just said is not right but i hope that some one can understand what i mean and provide an answer. PS) I am a programmer and I am in the process of building a hitmanesque game, just because i love that style of game and I want to increase my skills on something fun, so if you do know what i'm talking about have some examples with involving both models and programming (i use c++ and mainly Ogre3D at the moment but i am getting into unity and XNA) i would greatly appreciate it. Thanks.

    Read the article

  • Oracle Linux Partner Pavilion Spotlight - Part IV

    - by Ted Davis
    Welcome to the final Oracle Linux Partner Pavilion Spotlight Part IV.  Two days left till the Big Show. You are gearing up. We are gearing up. You can feel the excitement.  We can feel the excitement. This. Will. Be. The. Best. Show. EVER. See you at the Partner Pavilion (Moscone south # 1033) at Oracle OpenWorld. - Oracle Linux / Oracle VM Team HP and Oracle are pleased to announce another Oracle Validated Configuration based on the ProLiant DL980 server. Many choose to deploy Oracle workloads on the ProLiant DL980 based on the cost/performance ratio they achieve running Oracle Linux Unbreakable Enterprise Kernel. You can be confident that Oracle Validated Configurations based on ProLiant servers will help you achieve your most demanding performance goals. QLogic The QLogic-Oracle partnership spans over 20 years resulting in the most comprehensive line of Oracle Linux I/O adapter technology. Interface options include Ethernet, Fibre-Channel, and FCoE. Host side connectivity is offered in both low profile PCIe and Express Module PCIe form factors. QLogic software drives are jointly qualified and “in-box” with Oracle Linux 5.x, 6,x and Oracle VM enabling simplified installation and management while simultaneously taking risk out of the solution. Bringing innovations such as NPIV, T10-PI, and intelligent caching adapter technology to the Oracle Linux environment further strengthens the QLogic advantage. A big thank you to all of our Oracle Linux Partner Pavilion participants. We - they- look forward to meeting you next week at Oracle OpenWorld. If you've missed our three previous Partner Spotlight's - here are the links: Part I, Part II, Part III. 

    Read the article

  • Brownfield Support for OVMSS

    - by Owen Allen
    The area of virtualization saw quite a few enhancements with version 12.2. There's one particular virtualization enhancement that can make a big difference for a lot of people: support for brownfield Oracle VM Servers for SPARC. Brownfield refers to Oracle VM Servers for SPARC that were created outside of Ops Center. In older versions of Ops Center, you couldn't really do anything with them - Ops Center could only manage OVM Servers that it created. If you had OVM Servers outside of Ops Center, you'd have to recreate them if you wanted to manage them. In 12.2, though, this problem is cleared up. You can discover and manage OVM Servers for SPARC that you created outside of Ops Center, so long as the LDom Manager is running. When you discover the control domain, all of the logical domains are automatically discovered and managed and appear under the control domain in the Asset tree. If you want to use server pools and migrate the logical domains to a different Oracle VM Server for SPARC system, you'll need to move the metadata to a shared library and use shared Fibre Channel or iSCSI LUNs for the guest domain storage and add the server to a server pool. See the Oracle VM Server for SPARC chapter for more information.

    Read the article

  • Can a Linksys Router be the cause of bad speeds on a 1.5 mbps link.

    - by gramware
    We use a Linksys 5-port router at a smal organization with about 20 employees. We recently acquired a 1.5 mbps fibre link, but sometimes the link goes down and speeds are still low. On enquirey from the ISP, this was part of the response, However there maybe throttling due to the router in place. A Linksys is a low end router and may be unable to carried traffic of up to 1536Kbps. We are in a position to deploy a Cisco 871 router on test for 2 wks to eliminate that possibility. Also kindly advise the destination of the ping results they look to high. How true is that about the router throttling the network and need for a bigger one.

    Read the article

  • ZFS for Database Log Files

    - by user12620111
    I've been troubled by drop outs in CPU usage in my application server, characterized by the CPUs suddenly going from close to 90% CPU busy to almost completely CPU idle for a few seconds. Here is an example of a drop out as shown by a snippet of vmstat data taken while the application server is under a heavy workload. # vmstat 1  kthr      memory            page            disk          faults      cpu  r b w   swap  free  re  mf pi po fr de sr s3 s4 s5 s6   in   sy   cs us sy id  1 0 0 130160176 116381952 0 16 0 0 0 0  0  0  0  0  0 207377 117715 203884 70 21 9  12 0 0 130160160 116381936 0 25 0 0 0 0 0  0  0  0  0 200413 117162 197250 70 20 9  11 0 0 130160176 116381920 0 16 0 0 0 0 0  0  1  0  0 203150 119365 200249 72 21 7  8 0 0 130160176 116377808 0 19 0 0 0 0  0  0  0  0  0 169826 96144 165194 56 17 27  0 0 0 130160176 116377800 0 16 0 0 0 0  0  0  0  0  1 10245 9376 9164 2  1 97  0 0 0 130160176 116377792 0 16 0 0 0 0  0  0  0  0  2 15742 12401 14784 4 1 95  0 0 0 130160176 116377776 2 16 0 0 0 0  0  0  1  0  0 19972 17703 19612 6 2 92  14 0 0 130160176 116377696 0 16 0 0 0 0 0  0  0  0  0 202794 116793 199807 71 21 8  9 0 0 130160160 116373584 0 30 0 0 0 0  0  0 18  0  0 203123 117857 198825 69 20 11 This behavior occurred consistently while the application server was processing synthetic transactions: HTTP requests from JMeter running on an external machine. I explored many theories trying to explain the drop outs, including: Unexpected JMeter behavior Network contention Java Garbage Collection Application Server thread pool problems Connection pool problems Database transaction processing Database I/O contention Graphing the CPU %idle led to a breakthrough: Several of the drop outs were 30 seconds apart. With that insight, I went digging through the data again and looking for other outliers that were 30 seconds apart. In the database server statistics, I found spikes in the iostat "asvc_t" (average response time of disk transactions, in milliseconds) for the disk drive that was being used for the database log files. Here is an example:                     extended device statistics     r/s    w/s   kr/s   kw/s wait actv wsvc_t asvc_t  %w  %b device     0.0 2053.6    0.0 8234.3  0.0  0.2    0.0    0.1   0  24 c3t60080E5...F4F6d0s0     0.0 2162.2    0.0 8652.8  0.0  0.3    0.0    0.1   0  28 c3t60080E5...F4F6d0s0     0.0 1102.5    0.0 10012.8  0.0  4.5    0.0    4.1   0  69 c3t60080E5...F4F6d0s0     0.0   74.0    0.0 7920.6  0.0 10.0    0.0  135.1   0 100 c3t60080E5...F4F6d0s0     0.0  568.7    0.0 6674.0  0.0  6.4    0.0   11.2   0  90 c3t60080E5...F4F6d0s0     0.0 1358.0    0.0 5456.0  0.0  0.6    0.0    0.4   0  55 c3t60080E5...F4F6d0s0     0.0 1314.3    0.0 5285.2  0.0  0.7    0.0    0.5   0  70 c3t60080E5...F4F6d0s0 Here is a little more information about my database configuration: The database and application server were running on two different SPARC servers. Storage for the database was on a storage array connected via 8 gigabit Fibre Channel Data storage and log file were on different physical disk drives Reliable low latency I/O is provided by battery backed NVRAM Highly available: Two Fibre Channel links accessed via MPxIO Two Mirrored cache controllers The log file physical disks were mirrored in the storage device Database log files on a ZFS Filesystem with cutting-edge technologies, such as copy-on-write and end-to-end checksumming Why would I be getting service time spikes in my high-end storage? First, I wanted to verify that the database log disk service time spikes aligned with the application server CPU drop outs, and they did: At first, I guessed that the disk service time spikes might be related to flushing the write through cache on the storage device, but I was unable to validate that theory. After searching the WWW for a while, I decided to try using a separate log device: # zpool add ZFS-db-41 log c3t60080E500017D55C000015C150A9F8A7d0 The ZFS log device is configured in a similar manner as described above: two physical disks mirrored in the storage array. This change to the database storage configuration eliminated the application server CPU drop outs: Here is the zpool configuration: # zpool status ZFS-db-41   pool: ZFS-db-41  state: ONLINE  scan: none requested config:         NAME                                     STATE         ZFS-db-41                                ONLINE           c3t60080E5...F4F6d0  ONLINE         logs           c3t60080E5...F8A7d0  ONLINE Now, the I/O spikes look like this:                     extended device statistics                  r/s    w/s   kr/s   kw/s wait actv wsvc_t asvc_t  %w  %b device     0.0 1053.5    0.0 4234.1  0.0  0.8    0.0    0.7   0  75 c3t60080E5...F8A7d0s0                     extended device statistics                  r/s    w/s   kr/s   kw/s wait actv wsvc_t asvc_t  %w  %b device     0.0 1131.8    0.0 4555.3  0.0  0.8    0.0    0.7   0  76 c3t60080E5...F8A7d0s0                     extended device statistics                  r/s    w/s   kr/s   kw/s wait actv wsvc_t asvc_t  %w  %b device     0.0 1167.6    0.0 4682.2  0.0  0.7    0.0    0.6   0  74 c3t60080E5...F8A7d0s0     0.0  162.2    0.0 19153.9  0.0  0.7    0.0    4.2   0  12 c3t60080E5...F4F6d0s0                     extended device statistics                  r/s    w/s   kr/s   kw/s wait actv wsvc_t asvc_t  %w  %b device     0.0 1247.2    0.0 4992.6  0.0  0.7    0.0    0.6   0  71 c3t60080E5...F8A7d0s0     0.0   41.0    0.0   70.0  0.0  0.1    0.0    1.6   0   2 c3t60080E5...F4F6d0s0                     extended device statistics                  r/s    w/s   kr/s   kw/s wait actv wsvc_t asvc_t  %w  %b device     0.0 1241.3    0.0 4989.3  0.0  0.8    0.0    0.6   0  75 c3t60080E5...F8A7d0s0                     extended device statistics                  r/s    w/s   kr/s   kw/s wait actv wsvc_t asvc_t  %w  %b device     0.0 1193.2    0.0 4772.9  0.0  0.7    0.0    0.6   0  71 c3t60080E5...F8A7d0s0 We can see the steady flow of 4k writes to the ZIL device from O_SYNC database log file writes. The spikes are from flushing the transaction group. Like almost all problems that I run into, once I thoroughly understand the problem, I find that other people have documented similar experiences. Thanks to all of you who have documented alternative approaches. Saved for another day: now that the problem is obvious, I should try "zfs:zfs_immediate_write_sz" as recommended in the ZFS Evil Tuning Guide. References: The ZFS Intent Log Solaris ZFS, Synchronous Writes and the ZIL Explained ZFS Evil Tuning Guide: Cache Flushes ZFS Evil Tuning Guide: Tuning ZFS for Database Performance

    Read the article

  • Oracle OpenWorld - Events of Interest

    - by Larry Wake
    I mentioned the "Focus On Oracle Solaris" document the other day, which lists many of the Solaris-related events at Oracle OpenWorld this year; today I thought I'd highlight a few sessions you might find interesting. Monday, October 1st: 4:45 PM - Get Proactive: Best Practices for Maintaining and Upgrading Oracle Solaris (Moscone South 252) This session covers best practices for upgrading and patching and how to take advantage of unique technologies in Oracle Solaris 10 and 11. Learn how to get maximum value from My Oracle Support for both reactive and proactive requirements. Understand the benefits of secure remote access and how Oracle Support experts use collaborative shared sessions combined with Oracle Solaris technologies such as DTrace. Tuesday, October 2nd: 10:15 AM -  How to Increase Performance and Agility with an Open Data Center Fabric (Moscone South 200) If you haven't had a chance to hear about Xsigo Systems, this is a golden opportunity while you're at OpenWorld. Now part of Oracle, Xsigo's network virtualization technology is designed to increase both application performance and management efficiency, through a combination of software-defined network technology and the industry’s fastest fabric, allowing data center to converge Ethernet and Fibre Channel connectivity to a single fabric, to reduce complexity by 70 percent and CapEx by 50 percent while providing more I/O bandwidth to your applications. Wednesday, October 3rd: 10:15 AM - General Session: Oracle Solaris 11 Strategy, Engineering Insights, and Roadmap (Moscone South 103) Markus Flierl, head of Oracle Solaris Core Engineering, will outline the strategy and roadmap for Oracle Solaris,  how Oracle Solaris 11 is being deployed in cloud computing and the unique optimizations in Oracle Solaris 11 for the Oracle stack. The session also offers a sneak peek at the latest technology under development in Oracle Solaris, and what customers can expect to see in the coming updates. Plus, there are several Hands-On Labs: Monday, October 1st: 10:45 AM - 11:45 AM - Reduce Risk with Oracle Solaris Access Control to Restrain Users and Isolate Applications (Marriott Marquis - Salon 14/15) 4:45 PM - 5:45 PM - Managing Your Data with Built-In Oracle Solaris ZFS Data Services in Release 11  (Marriott Marquis - Salon 14/15) Tuesday, October 2nd: 1:15 PM - 2:15 PM - Virtualizing Your Oracle Solaris 11 Environment  (Marriott Marquis - Salon 10/11) Wednesday, October 3rd: 3:30 PM - 4:30 PM - Large-Scale Installation and Deployment of Oracle Solaris 11 (Marriott Marquis - Salon 14/15) There's plenty more--see the "Focus On Oracle Solaris" guide. See you next week in San Francisco!

    Read the article

  • Port forwarding on Fortigate 50B

    - by sindre j
    I have serious problems setting up port forwarding on a Fortigate 50B. The unit is basically running as factory default, the wan1 interface is connected to my fibre optic internet modem, and my lan is connected to the internal switch of the Fortigate. The factory default firewall policy allowing traffic from the internal interface to wan1 is kept and I'm able to access the interet as normal. Then I added a virtual ip and a firewall policy for allowing access from the internet to my local servers (ip 192.168.9.51) webserver (standard port 80). The settings I made are as follows. Edit Virtual IP Mapping Name : Server VIP External interface : wan1 Type : Static NAT Extermal IP Address/Range : 0.0.0.0 Mapped IP Address/Range : 192.168.9.51 Port Forwading : not checked Firewall policy Source interface/Zone : wan1 Source address : all Destination interface/Zone : internal Destination address : Server VIP Schedule : always Service : HTTP Action : ACCEPT no other settings checked What happens now is that I'm unable to access internet from my server, I'm not getting through to the webserver from internet either. I'm able to ping a site on the outside, but all web traffic is blocked, both ways. I've checked the documentation, but as far as I can tell I have set this up correctly. Anyone here with knowledge of Fortigate port forwading/NAT?

    Read the article

  • SQL Server 2008 Cluster Installation - First network name always fails

    - by boflynn
    I'm testing failover clustering in Windows Server 2008 to host a SQL Server 2008 installation using this installation guide. My base cluster is installed and working properly, as well as clustering the DTC service. However, when it comes time to install SQL Server, my first attempt at installation always fails with the same message and seems to "taint" the network name. For example, with my previous cluster attempt, I was installing SQL Server as VSQL. After approximately 15 attempts of installation and trying to resolve the errors, e.g. changing domain accounts for SQL, setting SPNs, etc., I typoed the network name as VQSL and the installation worked. Similarly on my current cluster, I tried installing with the SQL service named PROD-C1-DB and got the same errors as last time until I tried changing the name to anything else, e.g. PROD-C1-DB1, SQL, TEST, etc., at which point the install works. It will even install to VSQL now. While testing, my install routine was: Run setup.exe from patched media, selecting appropriate options After the install fails, I'd chose "Remove node from a SQL Server failover cluster" and remove the single, failed, node Attempt to diagnose problem, inspect event logs, etc. Delete the computer account that was created for the SQL Service from Active Directory Delete the MSSQL10.MSSQLSERVER folder from the shared data drive The error message I receive from the SQL Server installer is: The following error has occurred: The cluster resource 'SQL Server' could not be brought online. Error: The group or resource is not in the correct state to perform the requested operation. (Exception from HRESULT: 0x8007139F) Along with hundreds of the following errors in the Application event log: [sqsrvres] checkODBCConnectError: sqlstate = 28000; native error = 4818; message = [Microsoft][SQL Server Native Client 10.0][SQL Server]Login failed for user 'NT AUTHORITY\ANONYMOUS LOGON'. System configuration notes: Windows Server 2008 Enterprise Edition x64 SQL Server 2008 Enterprise Edition x64 using slipstreamed SP1+CU1 media Dell PowerEdge servers Fibre attached storage

    Read the article

  • Slow transfer speed between two servers

    - by Linux Guy
    I have two servers both network cards speed is 10Gbps The inbound bandwidth between two servers is 10Gbps , the outbound bandwidth internet bandwidth is 500Mpbs Both servers using public ip addresses in public and private network Both servers transfer and connection on nginx port , and the server B used for streaming media , like youtube stream videos I check the transfer speed using iperf utility From Server A to Server B # iperf -c 0.0.0.1 -p 8777 ------------------------------------------------------------ Client connecting to 0.0.0.1, TCP port 8777 TCP window size: 85.3 KByte (default) ------------------------------------------------------------ [ 3] local 0.0.0.0 port 38895 connected with 0.0.0.1 port 8777 [ ID] Interval Transfer Bandwidth [ 3] 0.0-10.8 sec 528 KBytes 399 Kbits/sec My Current Connections in Server B # netstat -an|grep ":8777"|awk '/tcp/ {print $6}'|sort -nr| uniq -c 2072 TIME_WAIT 28 SYN_RECV 1 LISTEN 189 LAST_ACK 139 FIN_WAIT2 373 FIN_WAIT1 3381 ESTABLISHED 34 CLOSING Server A Network Card Information Settings for eth0: Supported ports: [ TP ] Supported link modes: 100baseT/Full 1000baseT/Full 10000baseT/Full Supported pause frame use: No Supports auto-negotiation: Yes Advertised link modes: 10000baseT/Full Advertised pause frame use: No Advertised auto-negotiation: Yes Speed: 10000Mb/s Duplex: Full Port: Twisted Pair PHYAD: 0 Transceiver: external Auto-negotiation: on MDI-X: Unknown Supports Wake-on: d Wake-on: d Current message level: 0x00000007 (7) drv probe link Link detected: yes Server B Network Card Information Settings for eth2: Supported ports: [ FIBRE ] Supported link modes: 10000baseT/Full Supported pause frame use: No Supports auto-negotiation: No Advertised link modes: 10000baseT/Full Advertised pause frame use: No Advertised auto-negotiation: No Speed: 10000Mb/s Duplex: Full Port: Direct Attach Copper PHYAD: 0 Transceiver: external Auto-negotiation: off Supports Wake-on: d Wake-on: d Current message level: 0x00000007 (7) drv probe link Link detected: yes The problem is : as you can see from iperf utility, the transfer speed from server A to server B slow when i restart network service the connection will be ok , after 2 minutes , it's getting slow How could i troubleshoot slow speed issue and fix it in server B ? Notice : if there any other commands i should execute in servers for more information, so it might help resolve the problem , let me know in comments

    Read the article

  • Windows Server 2008 R2 install reboots unexpectedly during "Completing installation" phase

    - by knda
    I am attempting to install Windows Server 2008 R2 onto a Cisco UCS C201 M2 rack mounted server but am having major difficulties and wondering if anyone has some insight or items they could recommend for me to look at to get this one resolved. Installation is being attempted via the Cisco remote console (using CIMC's Virtual dvd-rom).. following the first phase of Setup where the installation files are copied to the target hard drive, then a reboot occurs to load Setup from the HDD, mid-way in the "Completing Installation" phase the system then reboots unexpectedly. System configuration Cisco UCS C201 M2 (2RU rack mounted server) 16GB RAM, 2x 73GB 15K SAS, 4x 300GB 10k SAS Add-on cards - Intel quad-port GigE card (no fibre channel cards) Storage - LSI MegaRAID SAS 9261-8i. onboard SATA is disabled (no SATA drives connected) KVM - Belkin No physical DVD-ROM.. :( I have... Run memtest86+, no RAM faults Disabled/enabled SATA support (BIOS) Attempted install from USB DVD-ROM, no effect Attempted unattended install scripted via Cisco Configuration Manager DVD provided Removed Belkin KVM in case that was causing drama Discovered that the Cisco website is "awesome" for searching for PDFs/Drivers cough, reverted back to Google Downloaded latest LSI drivers from LSI's site and used during Server 2008 install checked Windows ISO against checksum's from MS site checked Windows ISO by using it for an install in a VM Running out of ways to troubleshoot this as I am not sure how to enable any sort of 'verbose' mode during the setup process. Next step I have planned is to remove the Intel NIC and try the installation again.. Edit: Problem was the "Cisco INTEL QUAD PT GBE" (1000/PT) .. will have to see if this card is faulty or if it's just drivers.. thanks for the help.

    Read the article

  • SQL Server 2008 Cluster Installation - First network name always fails

    - by boflynn
    I'm testing failover clustering in Windows Server 2008 to host a SQL Server 2008 installation using this installation guide. My base cluster is installed and working properly, as well as clustering the DTC service. However, when it comes time to install SQL Server, my first attempt at installation always fails with the same message and seems to "taint" the network name. For example, with my previous cluster attempt, I was installing SQL Server as VSQL. After approximately 15 attempts of installation and trying to resolve the errors, e.g. changing domain accounts for SQL, setting SPNs, etc., I typoed the network name as VQSL and the installation worked. Similarly on my current cluster, I tried installing with the SQL service named PROD-C1-DB and got the same errors as last time until I tried changing the name to anything else, e.g. PROD-C1-DB1, SQL, TEST, etc., at which point the install works. It will even install to VSQL now. While testing, my install routine was: Run setup.exe from patched media, selecting appropriate options After the install fails, I'd chose "Remove node from a SQL Server failover cluster" and remove the single, failed, node Attempt to diagnose problem, inspect event logs, etc. Delete the computer account that was created for the SQL Service from Active Directory Delete the MSSQL10.MSSQLSERVER folder from the shared data drive The error message I receive from the SQL Server installer is: The following error has occurred: The cluster resource 'SQL Server' could not be brought online. Error: The group or resource is not in the correct state to perform the requested operation. (Exception from HRESULT: 0x8007139F) Along with hundreds of the following errors in the Application event log: [sqsrvres] checkODBCConnectError: sqlstate = 28000; native error = 4818; message = [Microsoft][SQL Server Native Client 10.0][SQL Server]Login failed for user 'NT AUTHORITY\ANONYMOUS LOGON'. System configuration notes: Windows Server 2008 Enterprise Edition x64 SQL Server 2008 Enterprise Edition x64 using slipstreamed SP1+CU1 media Dell PowerEdge servers Fibre attached storage

    Read the article

  • Decyphering Seagate drive model numbers?

    - by Stefan Lasiewski
    I'm comparing Seagate's Enterprise and Desktop drives for a variety of old and new servers. These servers come from different generations, so options like size (73GB, 2TB) and interface (SATA vs SAS 3.0Gbps vs SAS 6Gbps vs SCSI Ultra320) are widely variable. I'm trying to compare the sizes, speeds and interfaces, but I'm getting thrown off by different models. Also, their website is not the best. Does anyone know of a documented explanation of the Seagate model numbers? And is there a single spreadsheet which compares the features for all drives (or all 'Enterprise' drives?). Seagate drives have model numbers like this: Model ST3600057SS 6-Gb/s SAS 600 GB None at Cheetah® 15K Hard Drives Model ST373455LW Ultra320 SCSI 73.4 GB 68-Pin LW at Cheetah® 15K Hard Drives Model ST32000644NS SATA 3Gb/s 2 TB None at Constellation™ ES Hard Drives Model ST973452SS 6-Gb/s SAS 73 GB None Savvio® 15K Hard Drives Model ST9200011FS SATA 3Gb/s 200 GB Pulsar™ Solid State Drives I understand the model numbers read something like this: ST - SOMETHING1 - SIZE - SOMETHING2 - INTERFACE Where the fields mean something like this: ST : For 'Seagate'? 'Seagate Technoligies'? SOMETHING1 - This field has number, but I'm not sure what that represents. SIZE - Size in Gigabytes. This is a number like '73' or '300' or '2000' SOMETHING2 - This field also has a number, but I'm not sure what it means. INTERFACE - This field seems to indicate the Interface. 'SS' means SAS, 'FC' means Fibre Channel, but I don't see how to distinguish between 6Gbps SAS and 3Gbps SAS, or different SATA or FC speeds. I don't see a field which indicates the RPM (15K , 10K, 7.2K) etc. Is this part of the model number?

    Read the article

  • SBD killing both cluster nodes when there are even small SAN network problems

    - by Wieslaw Herr
    I am having problems with stonith SBD in a openais-based cluster. Some background: The active/passive cluster has two nodes, node1 and node2. They are configured to provide an NFS service to users. To avoid problems with split-brain, they are both configured to use SBD. SBD is using two 1MB disks available to the hosts via an multipath fibre-channel network. The problems start if something happens with the SAN network. For example, today one of the brocade switches got rebooted and both nodes lost 2 out of 4 paths to each disks, which resulted in both nodes committing suicide and rebooting. This, of course, was highly undesirable because a) there were paths left b) even if the switch would be out for 10-20 seconds a reboot cycle of both nodes would take 5-10 minutes and all NFS-locks would be lost. I tried increasing the SBD timeout values (to 10sec+ values, dump attached at the end), however a "WARN: Latency: No liveness for 4 s exceeds threshold of 3 s" hints that something isn't working as I would it expect to. Here is what I would like to know: a) Is SBD working as it should killing nodes when 2 paths are available? b) If not, is the multipath.conf file attached correct? The storage controller we use is an IBM SVC (IBM 2145), should there be any specific configuration for it? (as in multipath.conf.defaults) c) How should I go about increasing the timeouts in SBD attachements: Multipath.conf and sbd dump (http://hpaste.org/69537)

    Read the article

  • Routing public IPs (each a /32) through a VPN to another server

    - by Lee S
    Hopefully the title makes sense; I have a server currently in a colo facility, with many IP addresses routed to it. They are individual IPs and not in a contiguous block. Due to vastly improved connectivity (fibre) at home I am slowly bringing my infrastructure in-house for managability and eventually, cost savings. What I would like to do though is use the IP addresses allocated to my existing server, at home. I have an IP block allocated to me on my new ISP connection, but for a couple of reasons I'd like to make use of the colo ones for now: Ease of transition - lots of domains, dns, hard-coded IPs in programs, etc. Connectivity fallback. If my primary line goes down and switches to fallback 1 (dsl) or fallback 2 (4G), I lose access to the ISP-allocated IP block of IPs that are only presented on the primary WAN interface. What I'd like to achieve is my home virtualisation server (Proxmox/Debian-based) "dials in" to the colo server in the colo facility (also Proxmox/Debian) via VPN or similar, and gets to make use of the IP addresses that currently terminate on the colo box. If the primary connection to my ISP goes down and one of the fallback routes kicks in, the VPN tunnel will just time out and then be re-established on the backup connection instead. I'm sure this is doable, but I have no idea how. I'm not afraid to get my hands dirty, I just don't really know where to start?

    Read the article