Search Results

Search found 112 results on 5 pages for 'fibre'.

Page 3/5 | < Previous Page | 1 2 3 4 5  | Next Page >

  • HP DL380 using HP NC522SFP NIC shows supported link modes: not reported

    - by MikeS
    When using ethtool on this NIC, the supported link modes show "not reported". Any idea why this is the case? Settings for eth0: Supported ports: [ FIBRE ] Supported link modes: Not reported Supported pause frame use: Symmetric Supports auto-negotiation: No Advertised link modes: Not reported Advertised pause frame use: No Advertised auto-negotiation: No Speed: 10000Mb/s Duplex: Full Port: FIBRE PHYAD: 1 Transceiver: external Auto-negotiation: off Supports Wake-on: g Wake-on: g Current message level: 0x00002000 (8192) hw Link detected: yes

    Read the article

  • Creating a network link between 2 very close buildings

    - by Daniel Johnson
    I have a charity who have two adjacent medium sized modern detached houses (in the UK): the buildings stand next to each other and are less than 5 metres apart. They have DSL connected to a single computer in one of the buildings. They want to add a network with wireless, and want it to work across both buildings. Being a charity they need to keep costs down. The network would be used for sharing Word documents, e-mail, browsing and skyping. My initial thoughts were to connect the buildings with fibre. So: Option 1 Use fibre between the buildings. Sufficient cable and two TP-LINK MC100CM Fast Ethernet Media Converters. Cost ~£80.00. But there is the extra cost and hassle of running the cable down and up the external walls, lifting and relaying paving, and burying underground. Never having fitted fibre I'm also a little worried about going up the wall and then bending the cable at 90 degrees to go through the wall and into the building. Option 2 Use two TP-Link TL-WA7510N High Powered Outdoor 5Ghz 15dBi Wireless antennas to connect the buildings. There is a clear line of sight at first floor level. Cost ~£100. And much easier to fit than fibre! Is using the TL-WA7510Ns overkill? Is there something more suitable? I had hoped to use some Netgear stuff, e.g. two DGN2200, one in each house and also use them to provide the wireless link between the buildings. However, in bridge mode wireless client association is not available and repeater mode with client association only supports WEP security which isn't strong enough. Is there something similar that would be up to the job? Option 3 Connect the buildings with UTP cable. My concerns here are risk of electric shock due to a difference of potential between the buildings (or are they so close this shouldn't be an issue) and protection from lightning strikes. Is fitting lighting arrestors expensive? And what can be done to ameliorate against the risk of shock? This all falls outside my area of expertise so I would really appreciate some advice.

    Read the article

  • QLogic QLE8152 won't link up with a fiber loop

    - by Mike Pennington
    I have a Dell R710 running Debian Linux 6.0 (Squeeze). I installed a QLogic QLE8152 CNA in the PCI-E riser today and I have been trying to get the CNA's ethernet layer to come up after I put a fiber loop on it; I also scoped it with a light meter, and the SFP+ transceiver is getting the correct amount of light. The whole time I have been working on this problem, the lights on the CNA are blinking green at a rate of about 1 flash every 3 seconds. When I plug the fiber into a Juniper EX4500 10GE in a rack next to it, the Juniper's link stays down as well. I have to confess that this is my first wrangling with a CNA, so perhaps I'm doing something fundamentally wrong, but here is what I have found so far... First the basics... [mpenning@Finger ~]$ uname -a Linux Finger 2.6.32-5-amd64 #1 SMP Mon Oct 3 03:59:20 UTC 2011 x86_64 GNU/Linux [mpenning@Finger ~]$ cat /etc/issue Debian GNU/Linux 6.0 \n \l [mpenning@Finger ~]$ lspci -v shows that the card is properly installed (physically) 04:00.0 Ethernet controller: QLogic Corp. 10GbE Converged Network Adapter (TCP/IP Networking) (rev 02) Subsystem: QLogic Corp. Device 017e Flags: bus master, fast devsel, latency 0, IRQ 34 I/O ports at e000 [size=256] Memory at df8f0000 (64-bit, non-prefetchable) [size=16K] Memory at df900000 (64-bit, non-prefetchable) [size=1M] Expansion ROM at df800000 [disabled] [size=256K] Capabilities: [44] Power Management version 3 Capabilities: [4c] Express Endpoint, MSI 00 Capabilities: [88] MSI: Enable- Count=1/32 Maskable- 64bit+ Capabilities: [98] Vital Product Data Capabilities: [a0] MSI-X: Enable+ Count=8 Masked- Capabilities: [100] Advanced Error Reporting Capabilities: [138] Device Serial Number 00-c0-dd-ff-fe-1c-53-b4 Capabilities: [144] Power Budgeting <?> Kernel driver in use: qlge The output from ethtool shows that eth4 is the QLE8152... [mpenning@Finger ~]$ sudo ethtool eth4 Settings for eth4: Supported ports: [ FIBRE ] Supported link modes: 10000baseT/Full Supports auto-negotiation: No Advertised link modes: 10000baseT/Full Advertised pause frame use: No Advertised auto-negotiation: No Speed: 10000Mb/s Duplex: Full Port: FIBRE PHYAD: 0 Transceiver: external Auto-negotiation: on Current message level: 0x000060f7 (24823) Link detected: no [mpenning@Finger ~]$ sudo ethtool -i eth4 driver: qlge version: v1.00.00-b3 firmware-version: v1.35.11 bus-info: 0000:04:00.0 [mpenning@Finger ~]$ Finally, I tried modprobe -r qlge; modprobe -r qla2xxx and then modprobe qla2xxx; modprobe qlge to kick the system again... I don't see a smoking gun in /var/log/messages... Nov 17 19:46:21 finger kernel: [ 6212.298275] qlge 0000:04:00.1: PCI INT B disabled Nov 17 19:46:22 finger kernel: [ 6213.779974] qlge 0000:04:00.0: PCI INT A disabled Nov 17 19:46:33 finger kernel: [ 6224.554074] qla2xxx 0000:04:00.3: PCI INT D disabled Nov 17 19:46:33 finger kernel: [ 6224.555322] qla2xxx 0000:04:00.2: PCI INT C disabled Nov 17 19:46:54 finger kernel: [ 6245.625854] QLogic Fibre Channel HBA Driver: 8.03.01-k6 Nov 17 19:46:54 finger kernel: [ 6245.625888] qla2xxx 0000:04:00.2: PCI INT C -> GSI 35 (level, low) -> IRQ 35 Nov 17 19:46:54 finger kernel: [ 6245.626837] qla2xxx 0000:04:00.2: MSI-X vector count: 7 Nov 17 19:46:54 finger kernel: [ 6245.626841] qla2xxx 0000:04:00.2: Found an ISP8001, irq 35, iobase 0xffffc90012664000 Nov 17 19:46:54 finger kernel: [ 6245.627113] qla2xxx 0000:04:00.2: Configuring PCI space... Nov 17 19:46:54 finger kernel: [ 6245.639429] qla2xxx 0000:04:00.2: Configure NVRAM parameters... Nov 17 19:46:54 finger kernel: [ 6245.642597] qla2xxx 0000:04:00.2: Verifying loaded RISC code... Nov 17 19:46:54 finger kernel: [ 6245.642708] qla2xxx 0000:04:00.2: FW: Loading from flash (a0000)... Nov 17 19:46:55 finger kernel: [ 6246.273340] qla2xxx 0000:04:00.2: Allocated (64 KB) for FCE... Nov 17 19:46:55 finger kernel: [ 6246.273401] qla2xxx 0000:04:00.2: Allocated (64 KB) for EFT... Nov 17 19:46:55 finger kernel: [ 6246.273486] qla2xxx 0000:04:00.2: Allocated (1350 KB) for firmware dump... Nov 17 19:46:55 finger kernel: [ 6246.273856] scsi9 : qla2xxx Nov 17 19:46:55 finger kernel: [ 6246.274631] qla2xxx 0000:04:00.2: Nov 17 19:46:55 finger kernel: [ 6246.274633] QLogic Fibre Channel HBA Driver: 8.03.01-k6 Nov 17 19:46:55 finger kernel: [ 6246.274634] QLogic QLE8152 - QLogic PCI-Express Dual Channel 10GbE CNA Nov 17 19:46:55 finger kernel: [ 6246.274636] ISP8001: PCIe (5.0GT/s x4) @ 0000:04:00.2 hdma+, host#=9, fw=5.01.04 (8d4) Nov 17 19:46:55 finger kernel: [ 6246.274666] qla2xxx 0000:04:00.3: PCI INT D -> GSI 37 (level, low) -> IRQ 37 Nov 17 19:46:55 finger kernel: [ 6246.274748] qla2xxx 0000:04:00.3: MSI-X vector count: 7 Nov 17 19:46:55 finger kernel: [ 6246.274751] qla2xxx 0000:04:00.3: Found an ISP8001, irq 37, iobase 0xffffc900125c4000 Nov 17 19:46:55 finger kernel: [ 6246.275098] qla2xxx 0000:04:00.3: Configuring PCI space... Nov 17 19:46:55 finger kernel: [ 6246.287329] qla2xxx 0000:04:00.3: Configure NVRAM parameters... Nov 17 19:46:55 finger kernel: [ 6246.290624] qla2xxx 0000:04:00.3: Verifying loaded RISC code... Nov 17 19:46:55 finger kernel: [ 6246.290736] qla2xxx 0000:04:00.3: FW: Loading from flash (a0000)... Nov 17 19:46:55 finger kernel: [ 6246.920204] qla2xxx 0000:04:00.3: Allocated (64 KB) for FCE... Nov 17 19:46:55 finger kernel: [ 6246.920264] qla2xxx 0000:04:00.3: Allocated (64 KB) for EFT... Nov 17 19:46:55 finger kernel: [ 6246.920345] qla2xxx 0000:04:00.3: Allocated (1350 KB) for firmware dump... Nov 17 19:46:55 finger kernel: [ 6246.920749] scsi10 : qla2xxx Nov 17 19:46:55 finger kernel: [ 6246.921715] qla2xxx 0000:04:00.3: Nov 17 19:46:55 finger kernel: [ 6246.921716] QLogic Fibre Channel HBA Driver: 8.03.01-k6 Nov 17 19:46:55 finger kernel: [ 6246.921717] QLogic QLE8152 - QLogic PCI-Express Dual Channel 10GbE CNA Nov 17 19:46:55 finger kernel: [ 6246.921719] ISP8001: PCIe (5.0GT/s x4) @ 0000:04:00.3 hdma+, host#=10, fw=5.01.04 (8d4) Nov 17 19:46:58 finger kernel: [ 6249.519911] qlge 0000:04:00.0: PCI INT A -> GSI 34 (level, low) -> IRQ 34 Nov 17 19:46:58 finger kernel: [ 6249.533970] qlge 0000:04:00.0: QLogic 10 Gigabit PCI-E Ethernet Driver Nov 17 19:46:58 finger kernel: [ 6249.533975] qlge 0000:04:00.0: Driver name: qlge, Version: v1.00.00-b3. Nov 17 19:46:58 finger kernel: [ 6249.534856] qlge 0000:04:00.0: ql_display_dev_info: Function #0, Port 0, NIC Roll 0, NIC Rev = 1, XG Roll = 0, XG Rev = 1. Nov 17 19:46:58 finger kernel: [ 6249.534860] qlge 0000:04:00.0: ql_display_dev_info: MAC address 00:c0:dd:1c:53:b4 Nov 17 19:46:58 finger kernel: [ 6249.534888] qlge 0000:04:00.1: PCI INT B -> GSI 44 (level, low) -> IRQ 44 Nov 17 19:46:58 finger kernel: [ 6249.549109] qlge 0000:04:00.1: ql_display_dev_info: Function #1, Port 1, NIC Roll 0, NIC Rev = 1, XG Roll = 0, XG Rev = 1. Nov 17 19:46:58 finger kernel: [ 6249.549112] qlge 0000:04:00.1: ql_display_dev_info: MAC address 00:c0:dd:1c:53:b6 Any assistance getting a link up on this is greatly appreciated...

    Read the article

  • Apple XRaid questions

    - by luckytaxi
    I inherited an environment with a couple of apple xraid san. 1 - I have a 14 drive setup that's split into 5 LUNs on EACH side. The SAN goes into a fibre switch along w/ the servers that are attached to it. LUN masking is enabled on the SAN and as far as I know, there aren't any zoning on the fibre switch. Question, I have a server that's assigned two LUNs, one from each side of the controller. For some reason, it only sees one LUN (from the upper controller) and it doesn't see the one from the lower controller. The controller seems to be working fine as I have other servers attached to LUNs on the lower controller. 2 - I see a little "disclaimer" saying that any changes to the xraid will result in a reboot. So, if I add/remove hosts, this thing is going to reboot?!?!?!

    Read the article

  • Cabling: What to keep in stock?

    - by pehrs
    I have worked a few different places, each one with a different solution, so I would like to hear your suggestions and ideas. I am looking at a situation with multiple server-rooms. We have a mixture of copper (both ethernet and telephone), multi-mode fibre and single-mode fibre. We have all types of connectors: RJ-11, RJ-45, LC, SC, FC, SMA and several I probably forgot about. We have a lot of people working in the area, and keeping track of cables is turning into a full time job. So, here are a the questions: What types and lengths of cable do you keep in stock on site? Do you make your own or buy pre-made? Adapters? Dampeners? How do you manage cable inventory? How do you label the cables? Any other tricks to stop this from driving me crazy?

    Read the article

  • Direct IO enhancements in OVM Server for SPARC 2.2(a.k.a LDoms2.2)

    - by user12611315
    The Direct I/O feature has been available for LDoms customers since LDoms2.0. Apart from the latest SR-IOV feature in LDoms2.2, it is worth noting a few enhancements to the Direct I/O feature. These are: Support for Metis-Q and Metis-E cards. These cards are highly requested for support and are worth mentioning because they are the only combo cards containing both FibreChannel and Ethernet in the same card. With this support, a customer can have both SAN storage and network access with just one card and one PCIe slot assigned to a logical domain. This reduces cost and helps when there are less number of slots in a given platform. The following are the part numbers for these cards. I have tried to put the platforms on which each card is supported, but this information can get quickly outdated. The accurate information can be found at the Support Document.  Card Name  Part Number  Platforms Metis-Q: StorageTek Dual 8Gb Fibre Channel Dual GbE ExpressModule HBA, QLogic SG-XPCIEFCGBE-Q8-N  SPARC T3-4, T4-4 Metis-E: StorageTek Dual 8Gb Fibre Chanel Dual GbE ExpressModule HBA, Emulex SG-XPCIEFCGBE-E8-N SPARC T3-4, T4-4  Additional cards added to the portfolio of supported cards. This is mainly Powerville based Ethernet cards, the part numbers for these cards as below:  Part Number  Description  7100477 Sun Quad Port GbE PCI Express 2.0 Low Profile Adapter, UTP  7100481 Sun Dual Port GbE PCI Express 2.0 Low Profile Adapter, MMF  7100483 Sun Quad Port GbE PCI Express 2.0 ExpressModule, UTP  7110486 Sun Quad Port GbE PCI Express 2.0 ExpressModule, MMF    Note:  Direct IO feature has a hard dependency on the Root domain(PCIe bus owner, here Primary domain). That is, rebooting the Root domain for any reason may impact the logical domains having PCIe slots assigned with Direct IO feature. So rebooting a root domain need to be carefully managed. Also apply the failure-policy settings as described in the admin guide and release notes to deal with unexpected cases.

    Read the article

  • Faster, secure, protocol/code required for long-distance transfer.

    - by Chopper3
    I've ran into a problem and I'm looking for a new secure protocol/client/server that's faster over a 1Gb/s fibre link - let me tell you the story... I have a pair of redundant, diversely-routed, 1Gb/s links over a distance of around 250 miles or so (not dark fibre but a dedicated point to point link, not a mesh). At the 'client' end I have a HP DL380 G5 (2 x dual-core 2.66Ghz Xeon's, 4GB, Windows 2003EE 32-bit), at the 'server' end I have a HP BL460c G6 (2 x quad-core 2.53Ghz Xeons, 48GB, Oracle Linux 5.3 64-bit). I need to transfer around 500 x 2GB files per week from the client to the server machines per week - but the transfer NEEDS to be secure. Using both iPerf or regular FTP I can get ~80MB/s of transfer pretty consistently, which is great. Using WinSCP or Windows SFTP I can't seem to get more that ~3-4MB/s, at this point the server's CPU is 3% busy while CPU0 of the client goes to ~30% utilised. We've tried editing various TCP window sizes with little success. Both ends are connected to quite low-usage Cisco Cat6509's with Sup720's. I can replace the client machine with a newer machine and/or move it to Linux - but this will take time. Clearly these single-threaded secure Windows clients are introducing too much latency doing their encryption. So a few questions/thoughts; Are there any higher performing secure protocols or client software for Windows that I could try? I'm pretty protocol-gnostic so long as it'll work between Windows and Linux. Should I be using hardware to do the encryption, either in the client or the network parts? If so what would you recommend? I'm not convinced that just swapping the server would be that much faster, the CPU was only at 30% but then again that's higher than I'd have expected given the load - moving to Linux at the client end may be a better idea but would be quite disruptive. Am I missing a trick? Thanks in advance.

    Read the article

  • Heartbeat (Linux HA) and NetApp?

    - by Drew
    Does anyone have any experience setting up a high availability two node Linux cluster using heartbeat (linux-ha.org) and NetApp storage (preferably using SnapDrive for Linux)? Basically I would like to mount the same NetApp LUN over Fibre Channel to two servers in an Active/Passive mode (only one server can access the LUN at a time) Thanks!

    Read the article

  • Configuring VLAN's on two HP procurve switches

    - by pan
    Trying to route a new ISP (Microwave link) from one of my out buildings to my computer room and hence my firewall. Old ISP came direct into firewall. In the outbuilding the Microwave modem connects with cat5 to HP Procurve 2524 switch. Because this ISP is coming through my internal network, I plan on using a new vlan called "airspeed" only for this ISP traffic. Up until now I've just been using the Default_vlan on both HP switches (4108 + 2524). So far I've been unable to ping from my laptop to the ISP modem both of which are on the new vlan 2 ("Airspeed"). No traffic needs to cross from vlan 2 to vlan 1 so I've left the ports as untagged. I've used the subnet provide from my ISP as the new vlan 2 subnet. Can anybody see what I'm doing wrong here? I've added the configuration of both switch below. Rough diagram: Microwave modem (Gateway IP 77.75.00.49) | HP 2524 switch (port 24) | HP 2524 switch fibre link | HP 4108GL switch fibre link | HP 4108GL switch (port D1) | Laptop configured with IP 77.75.00.50 (for testing but will be connected to firewall) And my 4108GL config: ; J4865A Configuration Editor; Created on release #G.07.21 hostname "HP ProCurve Switch 4108GL" cdp run module 1 type J4864A module 2 type J4862B module 3 type J4862B module 4 type J4862B ip default-gateway 128.1.146.50 snmp-server community "public" Unrestricted snmp-server host 128.1.146.51 "public" Not-INFO snmp-server host 128.1.146.38 "public" vlan 1 name "DEFAULT_VLAN" untagged A1-A3,B1-B24,C1-C24,D2-D24 ip address 128.1.146.203 255.255.0.0 no untagged D1 exit vlan 2 name "Airspeed" untagged D1 ip address 77.75.00.51 255.255.255.248 exit Finally my 2524 config: ; J4813A Configuration Editor; Created on release #F.04.08 hostname "HP ProCurve Switch 2524" cdp run ip default-gateway 0.0.0.0 snmp-server community "public" Unrestricted snmp-server host 128.1.146.51 "public" Not-INFO snmp-server host 128.1.146.51 "public" snmp-server host 128.1.146.38 "public" vlan 1 name "DEFAULT_VLAN" untagged 1-23,25-26 no untagged 24 ip address 128.1.146.204 255.255.0.0 exit vlan 2 name "Airspeed" untagged 24 ip address 77.75.00.51 255.255.255.248 exit no aaa port-access authenticator active

    Read the article

  • Article about Sun ZFS Storage Appliances

    - by Owen Allen
    Sun ZFS Storage Appliances are versatile storage systems. Discovering and managing them in Ops Center, though, makes them even more versatile. If you discover a Sun ZFS Storage Appliance in Ops Center 12c, you can create iSCSI and Fibre Channel LUNS, and make the LUNs available to server pools and virtualization hosts as a storage library. Barbara Higgins has written an excellent article that walks you through the process of setting up a Sun ZFS Storage Appliance and discovering and managing it in Ops Center. If you're looking into ways to make a Sun ZFS Storage Appliance work for you, it's worth a look.

    Read the article

  • Join Our Call: Sun Storage 2500-M2 Announcement

    - by user797911
    Oracle's Sun Storage 2500-M2 array brings together the latest Fibre Channel (FC) and SAS2 technologies with Oracle's Sun Storage Common Array software from Oracle to create a robust solution that’s equally adept in an entry-level storage area network (SAN) for the mid-size business and integrating into an existing storage network within the enterprise. The Sun Storage 2500-M2 replaces Sun's Storage 2500 array product line and is designed so that the customer may have a quick qualification time for fast and easy deployment in the traditional 2500 environments. Jun Jang, Oracle Principal Product Manager will be hosting this 1 hour live call (a recording will be available), please join us to find out more: Event Date: 24-JUN-11 Event Time: 08:00 am PST/PDT/4pm UK time Web Registration and Access: http://oukc.oracle.com/static09/opn/login/?t=livewebcast|c=1031672594 Access for Mobile Devices: http://my.oracle.com/content/web/cnt636926 Call Provider: Intercall International Participant Dial-In Number: 706-634-8508 Additional International Dial-In Numbers Link: http://www.intercall.com/national/oracleuniversity/gdnam.html Dial-In Passcode: 96395

    Read the article

  • Join Our Call: Sun Storage 2500-M2 Announcement

    - by mseika
    Oracle's Sun Storage 2500-M2 array brings together the latest Fibre Channel (FC) and SAS2 technologies with Oracle's Sun Storage Common Array software from Oracle to create a robust solution that’s equally adept in an ! entry-level storage area network (SAN) for the mid-size business and integrating into an existing storage network within the enterprise. The Sun Storage 2500-M2 replaces Sun's Storage 2500 array product line and is designed so that the customer may have a quick qualification time for fast and easy deployment in the traditional 2500 environments. Jun Jang, Oracle Principal Product Manager will be hosting this 1 hour live call (a recording will be available), please join us to find out more:24. Jun 2011 08:00 am PST/PDT/4pm UK timeWeb Registration and AccessAccess for Mobile DevicesInternational Participant Dial-In Number: 706-634-8508Additional International Dial-In Numbers LinkDial-In Passcode: 6395

    Read the article

  • Announcing StorageTek LTO 6

    - by uwes
    Announcing StorageTek LTO-6 Full Height 8 Gb Fibre Channel IBM Tape Drives! We’re pleased to announce the availability of StorageTek LTO 6 tape drives in our StorageTek SL3000 and SL8500 modular tape libraries, which offers the following features: Higher Capacity - StorageTek LTO 6 drives have the ability to write 2.5 TB of native data to one LTO 6 cartridge, a 66% improvement over StorageTek LTO 5 Better Performance - StorageTek LTO 6 drive performance is 160 MB/sec (uncompressed), 14% faster than LTO 5 Investment Protection - StorageTek LTO 6 drives are backward read and write compatible to earlier generations for existing LTO customers  StorageTek LTO 6 will be in the system and orderable for the StorageTek SL3000 and SL8500 on Tuesday, December 4! For More Information Go To: Oracle.com Tape Page Oracle Technology Network Tape Page

    Read the article

  • Light Peak, "le successeur de l'USB 3", devrait débarquer dès la fin de l'année avec des taux de tra

    Pour Intel, l'USB 3 a déjà un successeur : Light Peak Qui pourra atteindre les 10 Gbps et qui devrait débarquer dès fin 2010 Il y a à peine une an, Intel dévoilait Light Peak, une technologie de transfert de données par fibre optique qui flirte avec les 10 Gbps... soit le double de l'USB 3. Or l'USB 3 semble tarder à s'imposer. Les propos de Kevin Kahn, senior manager chez Intel lors de l'Intel Developer Forum de Pékin, n'en ont que plus de résonance. "Nous voyons [Light Peak] comme le successeur logique de l'USB 3.0. D'une certaine manière nous aimerions réaliser le tout dernier cable dont vous aurez besoin". Même si une période de cohabitation des deux ...

    Read the article

  • Upgrading your Internet connection to obselescence

    - by TATWORTH
    Originally posted on: http://geekswithblogs.net/TATWORTH/archive/2013/10/11/upgrading-your-internet-connection-to-obselescence.aspxRecently I was approached by two UK Internet Service Providers to upgrade to a fibre connection. In each case I asked two questions:Can you provide me with a fixed IP Address?Is the equipment to be provided compatible with IPv6?None of the question was satisfactorily answered. One of the persons answering even suggested that granting a fixed IP Address would be a breach of security!I find it very disturbing that two companies that present themselves as innovative should still not be preparing for IPv6. The answer I would have expected was that all new equipment being supplied was IPv6 compatible and that plans were in hand for a switchover to IPv6. Instead new equipment would be supplied that would have to be replaced when IPv6 comes. Equally disturbing was that the call center people who answered did not know why a fixed IP address was important or why the change to IPv6 would have to come.I would rather not name and shame the two companies, however I will be looking elsewhere for my next Internet Service Provider.

    Read the article

  • Missing feature in Hyper-V from Virtual PC

    - by Kevin Shyr
    One thing I really miss is the ability to create shared folder between host and guest.  Virtual PC does this well, you can create Shared Folder to be used every time, or just this one.  I have read some posts on how to do this.  Some people suggest using ISO Creator to package up the files and mount the image to DVD drive, but what I need is truly a "shared" environment, so I'm currently looking into creating Virtual switch and creating an internal network between the host and guest.  Let's see how that works out. I would have loved to give Virtual SAN Manager a try, but I don't have a local Fibre Channel to set one up. I guess this might be an extension to my original post:  http://geekswithblogs.net/LifeLongTechie/archive/2011/05/05/windows-virtual-pc-vs.-hyper-v-virtual-machines-vs.-windows-virtual.aspx

    Read the article

  • Le prix de l'abonnement Internet en fonction de la consommation réelle serait envisagé, vers une fin des offres illimitées ?

    France : Le forfait internet au Go fixe est un scénario envisageable, bientôt la fin des offres illimitées ?Dans les prochains mois, il n'est pas exclu de voir se mettre en place une nouvelle législation autour de la facturation internet comme c'est déjà le cas en Allemagne où les forfaits dans le fixe sont déjà segmentés en fonction des protocoles (P2P, VoIP?) ou de la consommation générale.Depuis le mois d'avril dernier, Deutsche Telekom, l'opérateur principal en Allemagne, a en effet déjà imposé à ses nouveaux clients xDSL et fibre des quotas. Passé un certain seuil (75 Go pour les abonnés ADSL, 200 Go pour le VDSL, 300/400 Go pour les abonnés FTTH), les abonnés voient désormais leur débit sombrer à que...

    Read the article

  • W7 routing - traffic not going to default gateway

    - by Ian Macintosh
    I have a really strange Windows 7 IPv4 routing issue that I can't get to the bottom of. The summary of the issue is that the default gateway is set to 192.168.254.253, but that it is actually using a default gateway of 192.168.254.254. Here's a network diagram: .-,( ),-. .-( )-. .-----( internet )----.--------------------------. | '-( ).-' | | | '-.( ).-' | | v v v .------------. .------. .------. | 10mb Fibre | | ADSL | | ADSL | '------------' '------' '------' | | | | | | v v v .---------------------. .--------------------. .--------------------. | Juniper Box | | Draytek DSL Router | | Draytek DSL Router | |---------------------| |--------------------| |--------------------| | (public IP address) | | 172.16.0.x | | 172.16.0.x | '---------------------' '--------------------' '--------------------' | | | | | .-------------------' | v v v .-------------------------. .-----------------. | Draytek Dual WAN Router | | Untangle GW | |-------------------------| |-----------------| | 192.168.254.254 | | 192.168.254.253 | '-------------------------' '-----------------' | | | | | v v =================================== LAN =================================== | | | | v v .----------------. .----------------. | Windows 7 W/S | | Windows 7 W/S | |----------------| |----------------| | 192.168.254.38 | | 192.168.254.77 | '----------------' '----------------' This is a recently (a few weeks ago) converted fibre site with the original 2 DSL lines still attached and running. An Untangle (firewall) was installed with the fibre line. Here is the affected PC network configuration: C:\>ipconfig /allcompartments /all Windows IP Configuration ============================================================================== Network Information for Compartment 1 (ACTIVE) ============================================================================== Host Name . . . . . . . . . . . . : COMP36 Primary Dns Suffix . . . . . . . : XXXXXX.local Node Type . . . . . . . . . . . . : Broadcast IP Routing Enabled. . . . . . . . : No WINS Proxy Enabled. . . . . . . . : No DNS Suffix Search List. . . . . . : XXXXXX.local Ethernet adapter Local Area Connection 2: Connection-specific DNS Suffix . : XXXXXX.local Description . . . . . . . . . . . : Realtek PCIe GBE Family Controller #2 Physical Address. . . . . . . . . : C8-9C-DC-33-F1-65 DHCP Enabled. . . . . . . . . . . : Yes Autoconfiguration Enabled . . . . : Yes Link-local IPv6 Address . . . . . : fe80::3925:86a5:7066:ab92%15(Preferred) IPv4 Address. . . . . . . . . . . : 192.168.254.38(Preferred) Subnet Mask . . . . . . . . . . . : 255.255.255.0 Lease Obtained. . . . . . . . . . : 22 August 2012 10:20:32 Lease Expires . . . . . . . . . . : 30 August 2012 10:20:31 Default Gateway . . . . . . . . . : 192.168.254.253 DHCP Server . . . . . . . . . . . : 192.168.254.200 DHCPv6 IAID . . . . . . . . . . . : 315137244 DHCPv6 Client DUID. . . . . . . . : 00-01-00-01-14-4A-17-8D-10-78-D2-74-2F-8A DNS Servers . . . . . . . . . . . : 192.168.254.200 Primary WINS Server . . . . . . . : 192.168.254.200 NetBIOS over Tcpip. . . . . . . . : Enabled Tunnel adapter isatap.XXXXXX.local: Media State . . . . . . . . . . . : Media disconnected Connection-specific DNS Suffix . : XXXXXX.local Description . . . . . . . . . . . : Microsoft ISATAP Adapter Physical Address. . . . . . . . . : 00-00-00-00-00-00-00-E0 DHCP Enabled. . . . . . . . . . . : No Autoconfiguration Enabled . . . . : Yes Tunnel adapter Teredo Tunneling Pseudo-Interface: Media State . . . . . . . . . . . : Media disconnected Connection-specific DNS Suffix . : Description . . . . . . . . . . . : Teredo Tunneling Pseudo-Interface Physical Address. . . . . . . . . : 00-00-00-00-00-00-00-E0 DHCP Enabled. . . . . . . . . . . : No Autoconfiguration Enabled . . . . : Yes The routing table: C:\>route print =========================================================================== Interface List 15...c8 9c dc 33 f1 65 ......Realtek PCIe GBE Family Controller #2 1...........................Software Loopback Interface 1 10...00 00 00 00 00 00 00 e0 Microsoft ISATAP Adapter 11...00 00 00 00 00 00 00 e0 Teredo Tunneling Pseudo-Interface =========================================================================== IPv4 Route Table =========================================================================== Active Routes: Network Destination Netmask Gateway Interface Metric 0.0.0.0 0.0.0.0 192.168.254.253 192.168.254.38 10 127.0.0.0 255.0.0.0 On-link 127.0.0.1 306 127.0.0.1 255.255.255.255 On-link 127.0.0.1 306 127.255.255.255 255.255.255.255 On-link 127.0.0.1 306 192.168.254.0 255.255.255.0 On-link 192.168.254.38 266 192.168.254.38 255.255.255.255 On-link 192.168.254.38 266 192.168.254.255 255.255.255.255 On-link 192.168.254.38 266 224.0.0.0 240.0.0.0 On-link 127.0.0.1 306 224.0.0.0 240.0.0.0 On-link 192.168.254.38 266 255.255.255.255 255.255.255.255 On-link 127.0.0.1 306 255.255.255.255 255.255.255.255 On-link 192.168.254.38 266 =========================================================================== Persistent Routes: None IPv6 Route Table =========================================================================== Active Routes: If Metric Network Destination Gateway 1 306 ::1/128 On-link 15 266 fe80::/64 On-link 15 266 fe80::3925:86a5:7066:ab92/128 On-link 1 306 ff00 ::/8 On-link 15 266 ff00::/8 On-link =========================================================================== Persistent Routes: None And the strange routing as demonstrated by tracert: C:\>tracert -d www.bbc.co.uk Tracing route to www.bbc.net.uk [212.58.246.95] over a maximum of 30 hops: 1 1 ms 1 ms <1 ms 192.168.254.254 2 1 ms 1 ms 1 ms 172.16.0.254 3 17 ms 18 ms 16 ms XXXXXXXXXXXXXXX 4 18 ms 19 ms 19 ms XXXXXXXXXXXXXXX 5 22 ms 22 ms 22 ms XXXXXXXXXXXXXXX 6 22 ms 21 ms 22 ms XXXXXXXXXXXXXXX 7 21 ms 21 ms 22 ms 217.41.169.109 8 30 ms 32 ms 57 ms 109.159.251.227 9 46 ms 39 ms 35 ms 109.159.251.137 10 27 ms 66 ms 30 ms 109.159.254.116 ^C However, when done from another Windows 7 workstation: C:\Users\administrator>ipconfig /allcompartments /all Windows IP Configuration ============================================================================== Network Information for Compartment 1 (ACTIVE) ============================================================================== Host Name . . . . . . . . . . . . : PABX-BACKUP Primary Dns Suffix . . . . . . . : XXXXXX.local Node Type . . . . . . . . . . . . : Broadcast IP Routing Enabled. . . . . . . . : No WINS Proxy Enabled. . . . . . . . : No DNS Suffix Search List. . . . . . : XXXXXX.local Ethernet adapter Local Area Connection: Connection-specific DNS Suffix . : XXXXXX.local Description . . . . . . . . . . . : Realtek PCIe GBE Family Controller Physical Address. . . . . . . . . : 8C-89-A5-94-43-84 DHCP Enabled. . . . . . . . . . . : Yes Autoconfiguration Enabled . . . . : Yes Link-local IPv6 Address . . . . . : fe80::9479:1c11:6f9f:ae0b%11(Preferred) IPv4 Address. . . . . . . . . . . : 192.168.254.77(Preferred) Subnet Mask . . . . . . . . . . . : 255.255.255.0 Lease Obtained. . . . . . . . . . : 15 August 2012 08:27:18 Lease Expires . . . . . . . . . . : 27 August 2012 08:27:31 Default Gateway . . . . . . . . . : 192.168.254.253 DHCP Server . . . . . . . . . . . : 192.168.254.200 DHCPv6 IAID . . . . . . . . . . . : 244091301 DHCPv6 Client DUID. . . . . . . . : 00-01-00-01-16-C2-79-BE-8C-89-A5-94-43-84 DNS Servers . . . . . . . . . . . : 192.168.254.200 Primary WINS Server . . . . . . . : 192.168.254.200 NetBIOS over Tcpip. . . . . . . . : Enabled Tunnel adapter isatap.XXXXXX.local: Media State . . . . . . . . . . . : Media disconnected Connection-specific DNS Suffix . : XXXXXX.local Description . . . . . . . . . . . : Microsoft ISATAP Adapter Physical Address. . . . . . . . . : 00-00-00-00-00-00-00-E0 DHCP Enabled. . . . . . . . . . . : No Autoconfiguration Enabled . . . . : Yes Tunnel adapter Local Area Connection* 9: Media State . . . . . . . . . . . : Media disconnected Connection-specific DNS Suffix . : Description . . . . . . . . . . . : Microsoft 6to4 Adapter Physical Address. . . . . . . . . : 00-00-00-00-00-00-00-E0 DHCP Enabled. . . . . . . . . . . : No Autoconfiguration Enabled . . . . : Yes Tunnel adapter Teredo Tunneling Pseudo-Interface: Media State . . . . . . . . . . . : Media disconnected Connection-specific DNS Suffix . : Description . . . . . . . . . . . : Teredo Tunneling Pseudo-Interface Physical Address. . . . . . . . . : 00-00-00-00-00-00-00-E0 DHCP Enabled. . . . . . . . . . . : No Autoconfiguration Enabled . . . . : Yes C:\Users\administrator> And finally, doing a tracert from the 2nd workstation yields expected results: C:\Users\administrator>tracert -d www.bbc.co.uk Tracing route to www.bbc.net.uk [212.58.244.67] over a maximum of 30 hops: 1 <1 ms <1 ms <1 ms 192.168.254.253 2 1 ms 1 ms 1 ms 141.0.xxx.xxx 3 2 ms 2 ms 2 ms 141.0.xxx.xxx 4 7 ms 2 ms 2 ms 109.204.xxx.xxx 5 2 ms 2 ms 2 ms 95.177.0.7 6 3 ms 2 ms 2 ms 95.177.0.9 7 30 ms 2 ms 2 ms 95.177.0.2 8 2 ms 2 ms 2 ms 195.66.224.103 9 ^C As expected, it is routing via .253, and the 2nd hop is the inside interface of the Juniper NTU. I've not inspected the traffic yet. In particular, I was going to look for ICMP redirects, though why there would be an ICMP redirect at all is not really sensible? .254 used to be the default gateway before the fibre was installed. Any ideas? Doesn't make sense to me why there should be this routing issue :( The Draytek Dual WAN Router was rebooted, the PC was rebooted. The PC had the network disabled and then re-enabled. All the standard stuff when Windows looses the plot. Hopefully somebody recognises the symptoms! PS: Sorry for the long post, but I didn't want to leave something potentially relevant out. PPS: No iSCSI involved on/at this or any other workstation so Windows 7 routing traffic through the gateway for local addresses isn't the issue.

    Read the article

  • Visiting the Emtel Data Centre

    Back in February at the first event of the Emtel Knowledge Series (EKS) I spoke to various people at Emtel about their data centre here on the island. I was trying to see whether it would be possible to arrange a meeting over there for a selected group of our community members. Well, let's say it like this... My first approach wasn't that promising and far from successful but during the following months there were more and more occasions to get in touch with the "right" contact persons at Emtel to make it happen... Setting up an appointment and pre-requisites The major improvement came during a Boot Camp for Windows Phone 8.1 App development organised by Microsoft Indian Ocean Islands in cooperation with Emtel at the Emtel World, Ebene. Apart from learning bits and pieces regarding Universal Apps I took the opportunity to get in touch with Arvin Lockee, Sales Executive - Data, during our lunch break. And this really kicked off the whole procedure. Prior to get access to the Emtel data centre it is requested that you provide full name and National ID of anyone going to visit. Also, it should be noted that there was only a limited amount of seats available. Anyways, packed with this information I posted through the usual social media channels. Responses came in very quickly and based on First-come, first-serve (FCFS) principle I noted down the details and forwarded them to Emtel in order to fix a date and time for the visit. In preparation on our side, all attendees exchanged contact details and we organised transport options to go to the data centre in Arsenal. The day before and on the day of our meeting, Arvin send me a reminder to check whether everything is still confirmed and ready to go... Of course, it was! Arriving at the Emtel Data Centre As I'm coming from Flic En Flac towards the North, we agreed that I'm going to pick up a couple of young fellows near the old post office in Port Louis. All went well, except that Sean eventually might be living in another time zone compared to the rest of us. Anyway, after some extended stop we were complete and arrived just in time in Arsenal to meet and greet with Ish and Veer. Again, Emtel is taking access procedures to their data centre very serious and the gate stayed close until all our IDs had been noted and compared to the list of registered attendees. Despite having a good laugh at the mixture of old and new ID cards it was a straight-forward processing. The ward was very helpful and guided us to the waiting area at the entrance section of the building. Shortly after we were welcomed by Kamlesh Bokhoree, the Data Centre Officer. He gave us brief introduction into the rules and regulations during our visit, like no photography allowed, not touching the buttons, and following his instructions through the whole visit. Of course! Inside the data centre Next, he explained us the multi-factor authentication system using a combination of bio-metric data, like finger print reader, and "classic" pin panel. The Emtel data centre provides multiple services and next to co-location for your own hardware they also offer storage options for your backup and archive data in their massive, fire-resistant vault. Very impressive to get to know about the considerations that have been done in choosing the right location and how to set up the whole premises. It should also be noted that there is 24/7 CCTV surveillance inside and outside the buildings. Strengths of the Emtel TIER 3 Data Centre, Mauritius Finally, we were guided into the first server room. And wow, the whole setup is cleverly planned and outlined in the architecture. From the false floor and ceilings in order to provide optimum air flow, over to the separation of cold and hot aisles between the full-size server racks, and of course the monitored air conditions in order to analyse and watch changes in temperature, smoke detection and other parameters. And not surprisingly everything has been implemented in two independent circuits. There is a standardised classification for the construction and operation of data centres world-wide, and the Emtel's one has been designed to be a TIER 4 building but due to the lack of an alternative power supplier on the island it is officially registered as a TIER 3 compliant data centre. Maybe in the long run there might be a second supplier of energy next to CEB... time will tell. Luckily, the data centre is integrated into the National Fibre Optic Gigabit Ring and Emtel already connects internationally through diverse undersea cable routes like SAFE & LION/LION2 out of Mauritius and through several other providers for onwards connectivity. The data centre is part of the National Fibre Optic Gigabit Ring and has redundant internet connectivity onwards. Meanwhile, Arvin managed to join our little group of geeks and he supported Kamlesh in answering our technical questions regarding the capacities and general operation of the data centre. Visiting the NOC and its dedicated team of IT professionals was surely one of the visual highlights. Seeing their wall of screens to monitor any kind of activities on the data lines, the managed servers and the activity in and around the building was great. Even though I'm using a multi-head setup since years I cannot keep it up with that setup... ;-) But I got a couple of ideas on how to improve my work spaces here at the office. Clear advantages of hosting your e-commerce and mobile backends locally After the completely isolated NOC area we continued our Q&A session with Kamlesh and Arvin in the second server room which is dedictated to shared environments. On first thought it should be well-noted that there is lots of space for full-sized racks and therefore co-location of your own hardware. Actually, given the feedback that there will be upcoming changes in prices the facilities at the Emtel data centre are getting more and more competitive and interesting for local companies, especially small and medium enterprises. After seeing this world-class infrastructure available on the island, I'm already considering of moving one of my root servers abroad to be co-located here on the island. This would provide an improved user experience in terms of site performance and latency. This would be a good improvement, especially for upcoming e-commerce solutions for two of my local clients. Later on, we actually started the conversation of additional services that could be a catalyst for the local market in order to attract more small and medium companies to take the data centre into their evaluations regarding online activities. Until today Emtel does not provide virtualised server environments but there might be ongoing plans in the future to cover this field as well. Emtel is a mobile operator and internet connectivity provider in the first place, entering a market of managed and virtualised server infrastructures including capacities in terms of cloud storage and computing are rather new and there is a continuous learning curve at Emtel, too. You cannot just jump into a new market and see how it works out... And I appreciate Emtel's approach towards a solid fundament and then building new services on top of that. Emtel as a future one-stop-shop service provider for all your internet and telecommunications needs. Emtel's promotional video about their TIER 3 data centre in Arsenal, Mauritius More details are thoroughly described in Emtel's brochure of their data centre. Check out their PDF document here. Thanks for this opportunity Visiting and walking through the Emtel data centre for more than 2 hours was a great experience. As representative of the Mauritius Software Craftsmanship Community (MSCC) I would like to thank anyone at Emtel involved in the process of making it happen, and especially to Arvin Lockee and Kamlesh Bokhoree for their time and patience in explaining the infrastructure and answering all the endless questions from our members. Thank You!

    Read the article

  • What's causing Remote Access error 807 using rasdial.exe to connect to a PPTP VPN?

    - by Dylan Beattie
    I'm using rasdial.exe to connect an offsite server to our VPN. Remote box is a Windows 2008 x64 server; the VPN host at this end is a Watchguard Firebox x750e running Fireware 10.2 It connects fine about 20-30% of the time. The rest of the time I get: Remote Access error 807 - The network connection between your computer and the VPN server was interrupted. This can be caused by a problem in the VPN transmission and is commonly the result of internet latency or simply that your VPN server has reached capacity. Please try to reconnect to the VPN server. If this problem persists, contact the VPN administrator and analyze quality of network connectivity. For more help on this error: Type 'hh netcfg.chm' In help, click Troubleshooting, then Error Messages, then 807 The VPN isn't full, and it's 100Mb dedicated fibre on both ends so I can't believe it's a connectivity issue - especially since I'm RDP'ed into the remote box whilst trying to do this! Any bright ideas as to what might be causing the problem? Thanks, Dylan

    Read the article

  • 19" Rackmountable fast storage arrays

    - by Eruditass
    I'm in need of some fast (15+ GB/s write) and somewhat large (50 TB+) storage subsystem with a standard storage interface. I'd prefer something other than Fibre Channel, which admittedly appears to be the most standard interface. RAID 5 is sufficient. What are the cheapest / smallest products from vendors to look at for building this subsystem? I've looked at DDN and TMS so far. Small: Under 20U Cheap: Under a million Edit: I'd really like to cut back costs as much as possible at the expense of capacity. How cheap can these bandwidth requirements be met?

    Read the article

  • Error adding 4tb LUN (Raw Device Mapping) to ESX4 VM

    - by Tom Gardiner
    Hi guys, I'm trying to map an existing 4tb LUN from a Fibre Channel SAN, through to a VM in my ESX4 environment. It keeps telling me that the VMDK file size exceeds the the maximum size supported by the datastore. I've tried in Physical compatibility mode, and also both Virtual styles. I'm a little confused by this as we had the same LUN mapped through to another VM when we were running ESX3.5... I've also noticed that some of my other RAW mappings are generating extremely large VMDK files on the ESX servers. Does anyone know if this change in behaviour is intentional? And if so why? It doesn't seem to me that if the LUN is mapped directly to the VM that it's size should be relevant. We're running 4.0.0 build 236512, and 4.0.0 build 219382 and I've not had any success on either. Any insight or advice would be much appreciated! TG

    Read the article

< Previous Page | 1 2 3 4 5  | Next Page >