  • setting up vpn server

    - by Lock
    I need help in visualising how to setup our VPN box when we move to our new network with Telstra. We have a safe@office 500P, which has a public IP and a private IP of 192.168.19.2. It is physically connected to our router, which has 4 different interfaces, one being 192.168.19.1. On the VPN box, we have a static route to forward everything to 192.168.19.1 which is the router, and from there it works out where to go. Now, we are moving to a Telstra WAN and things are setup a little differently. Our head office router has only 3 interfaces- 1 is for the link to the switch that has the fibre connection (so our route to the internet and other branches), 1 is for our 10.10.20.x network and one is for the local branch network. I really have no idea how to set this up as with the new setup, we will not have a port for it to plug into on the router. Could I just plug it into the 10.10.20.x network? Would I have to give it a public IP or can we just forward through the ports that it would use? Another suggestion was to VLAN our switch into two networks- one for the 10.10.20.x network and one for the network the VPN currently sits on (192.168.19.x), and setup the router to trunk between the port and the switch. Not sure how to do this. Sorry VPN's are definitely not my strong suit. Any advice appreciated!

    Read the article

  • Xsigo and Oracle's Storage

    - by Philippe Deverchère
    Xsigo, a virtual network infrastructure provider, has recently been acquired by Oracle. Following this acquisition, one might ask ourselves why it is important to Oracle and how Oracle's storage is going to benefit on the long term from this virtualized infrastructure layer. Well, the first thing to understand is that Virtual Networking addresses both network and storage connectivity. Oracle Virtual Networking, as the Xsigo technology is now called, connects any server to any network and storage, so this is not just about connecting servers to the Internet or Intranet. It is also for a large part connecting servers to NAS and SAN storage. Connecting servers to storage has become increasingly complex in the past few years because of the strong emergence of virtualization at the Operating System level. 50% of enterprise workloads are now virtualized, up from 18% in 2009, resulting in a strong consolidation of various applications in a high density server footprint. At the same time, server I/O capability increased 8x in the last 8 years. All this has pushed IT administrators to multiply the number of I/O connections in the back-end of their physical servers, resulting in a messy and very hard to manage networking infrastructure. Here is a typical view of a rack back-end when no virtual networking is used. We consider that today: - 75% of users have ten or more Ethernet ports per server - 85% of users have two or more SAN ports per server - 58% have had to add connectivity to a server specifically for VMs - 65% consider cable reduction a priority The average is 12 or more ports per server, resulting in an extremely complex infrastructure to manage. What Oracle wants to achieve with its Oracle Virtual Networking offering is pretty simple. The objective is to eliminate the complexity through a dramatic reduction of cabling between servers and storage/networks. It is also to provide a software based management system so that any server can be connected to any network or any storage, on demand, and without physical intervention on the infrastructure. At the end of the day, the picture on the left shows what one wants to get for the back-end of customer's racks: just a couple of connections on each physical server to provide a simple, agile and fast network infrastructure for both storage and networking access. This is exactly what the Oracle Virtual Networking solution does. It transforms a complex, error-prone, difficult to manage and expensive networking infrastructure into a simple, high performance and agile solution for the data center. Practically speaking, and for the sake of simplicity, imagine that each server just hosts a minimal number of physical InfiniBand HCAs (Host Channel Adapter) with two links (for redundancy) onto the Oracle Fabric Interconnect director. Using the Oracle Fabric Manager software, you'll then be able to create virtual NICs and HBAs (called vNIC and vHBA) that will be seen by the servers as standard NICs and HBAs and associate them to networks and storage systems which are physically connected to the back-end of the director through standard Fibre Channel and Ethernet GbE/10GbE ports. In addition to this incredibly simple "at-a-click" connectivity capability, the Oracle Virtual Networking solution offers powerful features such as network isolation, Quality of Service, advanced performance monitoring and non-disruptive reconfiguration, migration and scalability of networking infrastructure. So let's go back now to our initial question: why is Oracle Virtual Networking especially important to Oracle's storage solutions? After all, one could connect any storage in the back-end of the Oracle Fabric Interconnect directors, right? The answer is pretty simple: since Oracle owns both the virtualized networking infrastructure and the storage (ZFS-SA, Pillar Axiom and tape), it is possible to imagine several ways in the future to add value when it comes to connect storage to a virtualized storage network: enhanced storage capabilities, converged management between storage and network, improved diagnostic capabilities and optimized integration resulting in higher performance and unique features/functions. Of course, all this is not going to be done overnight, and future will tell us is which evolutions come first. But there is little doubt that the integration of Xsigo within Oracle is going to create opportunities for Oracle's storage!

    Read the article

  • It happens only at Devoxx ...

    - by arungupta
    After attending several Java conferences world wide, this was my very first time at Devoxx. Here are some items I found that happens only at Devoxx ... Pioneers of theater-style seating - This not only provides comfortable seating for each attendee but the screens are very clearly visible to everybody in the room. Intellectual level of attendees is very high - Read more explanation on the Java EE 6 lab blog. In short, a lab, 1/3 of the content delivered at Devoxx 2011, could not be completed at other developer days in more than 1/3 the time. Snack box for lunches - Even though this suits well to the healthy lifestyle of multiple-snacks-during-a-day style but leaves attendees hungry sooner in the day. The longer breaks before the next snack in the evening does not help at all. Fortunately, Azure cupcakes and Android ice creams turned out to be handy. I finally carried my own apple :-) Wrist band instead of lanyard - The good part about this is that once tied to your hand then you are less likely to forget in your room. But OTOH you are a pretty much a branded conference attendee all through out the city. It was cost effective as it costed 20c as opposed to 1 euro for the lanyard. Live streaming from theater #8 (the biggest room) on parleys.com All talks recorded and released on parleys.com over next year. This allows attendees to not to miss any session and watch replay at their own leisure. Stephan promised to start sharing the sessions by mid December this year. No need to pre-register for a session - This is true for most of the conferences but bigger rooms (+ overflow room for key sessions) provide sufficient space for all those who want to attend the session. And of course all sessions are available on parleys.com anyway! Community votes on whiteboard - Devoxx attendees gets a chance to vote on topics ranging from their favorite non-Java language, operating system, or love from Oracle. Captured pictures at the end of Day 2 are shown below. Movie on the last but one night - This year it was The Adventures of Tintin and was lots of fun. Fries with mayo - This is a typical Belgian thing. Guys going in ladies room to avoid the long queues ... wow! Tweet wall everywhere and I mean literally everywhere, in rooms, hallways, front desk, and other places. The tweet picking algorithm was not very clear as I never saw my tweet appear on the wall ;-) You can also watch it at wall.devoxx.com. Cozy speaker dinner with great food and wine List of parallel and upcoming sessions displayed on the screen - This makes the information more explicit with the attendees. REST API with multiple mobile clients - This API is also used by some other conferences as well. And there always is iphone.devoxx.com. Steering committee members were recognized multiple times. The committee members were clearly identifiable wearing red hoodies. The wireless SSID was intuitive "Devoxx" but hidden to avoid some crap from Microsoft Windows. All of 9000 addresses were used up most of the times with each attendee having multiple devices. A 1 GB fibre optic cable was stretched to Metropolis to support the required network bandwidth. Stephan is already planning to upgrade the equipment and have a better infrastructure next year. Free water, soda, juice in a cooler Kinect connected to TV screens so that attendees can use their hands to browse through the list of sesssions. #devoxxblog, #devoxxwomen, #devoxxfrance, #devoxxgreat, #devoxxsuggestions And Devoxx attendees are called Devoxxians ... how cool is that ? :-) What other things do you think happen only at Devoxx ? And now the pictures from the community whiteboard: And a more complete album (including bigger pics of community votes) is available below:

    Read the article

  • Optical SPDIF audio from motherboard not working with receiver

    - by simon b
    Hi, I hope someone can help; I can't get my SPDIF optical out working through my receiver and all the responses I can see on the web assume you have a sound card, while I settled for the (seemingly high end) sound on my motherboard (Asus P7P55D-E PRO), which appears to limit some of my options. My set-up is a "new out of the box" one and is: *Windows 7 PC (using PowerDVD10 for DVDs/Blurays and Windows media player for music) *Asus P7P55D-E PRO motherboard - has 8-channel audio TRS jacks and SPDIF optical and coaxial out *An old Yamaha receiver, whose only multi-channel input options are optical in and 6 channel RCA in. However, it still can handle DTS and DD *Boston Acoustic Soundware XS 5.1 speakers I've currently got the SPDIF optical out from the motherboard connected to the in on my receiver, have SPDIF enabled in the sound menu and the light is glowing red down the fibre. But I'm getting no sound at all. What I want is to be able to play DVDs/BluRays in 5.1 but also to be able to play music in multi-channel mode (even though I know this will be "fake" multichannel; it's more about where I sit in the room and my requirement to use the sub because the Boston is a satellite/sub set-up) My questions are: *Will optical work at all for multi-channel? THe latest posts I can see suggest it does but some people seem to say optical only outputs stereo. Whom to believe? *Even if it does work, I've read that I have to disable AC-3 decoding, or make various other changes, which don't seem to be possible without the menu options that a sound-card brings. Is the motherboard-only option just too inflexible? *Although my SPDIF device is enabled in the sound menu, it insists under "Jack information" that it is a "rear panel RCA jack", when of course it is not (both TOSLINK and rCA jacks do exist). Has the PC just forgotten that it has an optical? *I think I could relatively easily connect the 8-channel 3.5mm TRS jacks to my receiver 6-ch input jacks by way of TRS/RCA cables, but would that not stop me from being able to play music from media-player in multi-channel mode, as I'm not sure the motherboard can cope *Or do I need to bite the bullet and buy a sound-card? And if so, how can I be sure the one I get doesn't have the same problem? Any thoughts gratefully received, Cheers, simon

    Read the article

  • OS X server large scale storage and backup

    - by user135217
    I really hope this question doesn't come across as trolling or asking for buying advice. It's not intended. I've just started working for a small ad agency (40 employees). I actually quit being a system administrator a few years ago (too stressful!), but the company we're currently outsourcing our IT stuff to is doing such a bad job that I've felt compelled to get involved and do what I can to improve things. At the moment, all the company's data is stored on an 8TB external firewire drive attached to a Mac Mini running OS X Server 10.6, which provides filesharing (using AFP) for the whole company. There is a single backup drive, which is actually a caddy containing two 3TB hard drives arranged in RAID 0 (arrggghhhh!), which someone brings in as and when and copies over all the data using Carbon Copy Cloner. That's the entirety of the infrastructure, and the whole backup and restore strategy. I've been having sleepless nights. I've just started augmenting the backup process with FreeBSD, ZFS, sparse bundles and snapshot sends to get everything offsite. I think this is a workable behind the scenes solution, but for people's day to day use I'm struggling. Given the quantity and importance of the data, I think we should really be looking towards enterprise level storage solutions, high availability and so on, but the whole company is all Mac all the time, and I cannot find equipment that will do what we need. No more Xserve; no rack storage; no large scale storage at all apart from that Pegasus R6 that doesn't seem all that great; the Mac Pro has fibre channel, but it's not a real server and it's ludicrously expensive; Xsan looks like it's on the way out; things like heartbeatd and failoverd have apparently been removed from Lion Server; the new Mac Mini only has thunderbolt which severely limits our choices; the list goes on and on. I'm really, really not trying to troll here. I love Macs, but I just genuinely don't know where I'm supposed to look for server stuff. I have considered Linux or FreeBSD and netatalk for serving files with all the server-y goodness those OSes bring, but some the things I've read make me wonder if it's really the way to go. Also, in my own (admittedly quite cursory) experiments with it, I've struggled to get decent transfer speeds. I guess there's also the possibility of switching everyone off AFP and making them use SMB or NFS, but I understand that this can cause big problems with resource forks and file locks. I figure there must be plenty of all Mac companies out there. If you're the sysadmin at one, what do you use? Any suggestions very gratefully received.

    Read the article

  • Leaks on Wikis: "Corporations...You're Next!" Oracle Desktop Virtualization Can Help.

    - by adam.hawley
    Between all the press coverage on the unauthorized release of 251,287 diplomatic documents and on previous extensive releases of classified documents on the events in Iraq and Afghanistan, one could be forgiven for thinking massive leaks are really an issue for governments, but it is not: It is an issue for corporations as well. In fact, corporations are apparently set to be the next big target for things like Wikileaks. Just the threat of such a release against one corporation recently caused the price of their stock to drop 3% after the leak organization claimed to have 5GB of information from inside the company, with the implication that it might be damaging or embarrassing information. At the moment of this blog anyway, we don't know yet if that is true or how they got the information but how did the diplomatic cable leak happen? For the diplomatic cables, according to press reports, a private in the military, with some appropriate level of security clearance (that is, he apparently had the correct level of security clearance to be accessing the information...he reportedly didn't "hack" his way through anything to get to the documents which might have raised some red flags...), is accused of accessing the material and copying it onto a writeable CD labeled "Lady Gaga" and walking out the door with it. Upload and... Done. In the same article, the accused is quoted as saying "Information should be free. It belongs in the public domain." Now think about all the confidential information in your company or non-profit... from credit card information, to phone records, to customer or donor lists, to corporate strategy documents, product cost information, etc, etc.... And then think about that last quote above from what was a very junior level person in the organization...still feeling comfortable with your ability to control all your information? So what can you do to guard against these types of breaches where there is no outsider (or even insider) intrusion to detect per se, but rather someone with malicious intent is physically walking out the door with data that they are otherwise allowed to access in their daily work? A major first step it to make it physically, logistically much harder to walk away with the information. If the user with malicious intent has no way to copy to removable or moble media (USB sticks, thumb drives, CDs, DVDs, memory cards, or even laptop disk drives) then, as a practical matter it is much more difficult to physically move the information outside the firewall. But how can you control access tightly and reliably and still keep your hundreds or even thousands of users productive in their daily job? Oracle Desktop Virtualization products can help.Oracle's comprehensive suite of desktop virtualization and access products allow your applications and, most importantly, the related data, to stay in the (highly secured) data center while still allowing secure access from just about anywhere your users need to be to be productive.  Users can securely access all the data they need to do their job, whether from work, from home, or on the road and in the field, but fully configurable policies set up centrally by privileged administrators allow you to control whether, for instance, they are allowed to print documents or use USB devices or other removable media.  Centrally set policies can also control not only whether they can download to removable devices, but also whether they can upload information (see StuxNet for why that is important...)In fact, by using Sun Ray Client desktop hardware, which does not contain any disk drives, or removable media drives, even theft of the desktop device itself would not make you vulnerable to data loss, unlike a laptop that can be stolen with hundreds of gigabytes of information on its disk drive.  And for extreme security situations, Sun Ray Clients even come standard with the ability to use fibre optic ethernet networking to each client to prevent the possibility of unauthorized monitoring of network traffic.But even without Sun Ray Client hardware, users can leverage Oracle's Secure Global Desktop software or the Oracle Virtual Desktop Client to securely access server-resident applications, desktop sessions, or full desktop virtual machines without persisting any application data on the desktop or laptop being used to access the information.  And, again, even in this context, the Oracle products allow you to control what gets uploaded, downloaded, or printed for example.Another benefit of Oracle's Desktop Virtualization and access products is the ability to rapidly and easily shut off user access centrally through administrative polices if, for example, an employee changes roles or leaves the company and should no longer have access to the information.Oracle's Desktop Virtualization suite of products can help reduce operating expense and increase user productivity, and those are good reasons alone to consider their use.  But the dynamics of today's world dictate that security is one of the top reasons for implementing a virtual desktop architecture in enterprises.For more information on these products, view the webpages on www.oracle.com and the Oracle Technology Network website.

    Read the article

  • Information Indepth Newsletter - Linux Edition

    - by Paulo Folgado
    INFORMATION INDEPTH NEWSLETTERLinux Edition February 2011 Stay Connected:  NEWS Now Available: Oracle Linux 6 Get the latest release of Oracle Linux 6, which includes Unbreakable Enterprise Kernel.Download Oracle Linux 6 Read More Customers Succeed by Using Oracle Exadata with Oracle Linux Watch IT executives from Bank of America, Linkshare, and Johns Hopkins as they talk about the business challenges they faced and why they chose to use Oracle Linux along with Oracle Exadata as the solution. Watch Now Video Interview: Oracle Senior Vice President Wim Coekaerts Watch Wim Coekaerts, senior vice president, Linux and Virtualization Engineering, as he talks about use cases for Oracle VM Templates as well as the Unbreakable Enterprise Kernel for Linux.Watch Now Hot Off the Press: Migrate Your IBM AIX Environment to Oracle Linux This new white paper provides recommendations for planning and implementing the migration of applications from an IBM Power System running AIX to Oracle's Sun Fire X4800 Server with Intel Xeon 7560 Processor running Oracle Linux 5.5.Read More  Back to Top BLOGOSPHERE Just Launched: The Oracle Linux Blog Follow our new Oracle Linux blog  to hear the latest updates, product news, upcoming events, and all the latest happenings, directly from the Linux team at Oracle. Back to Top TECH DIVE NEW: Linux/Oracle Solaris CommandComparo Site from Oracle Technology NetworkThis site gives equivalent command syntax in Oracle Solaris 10 and Oracle Enterprise Linux 5 for common administrative tasks--focusing particularly on tasks that have tricky syntax or that you frequently need to double check. It acts as a quick reference for administrators who operate in these two OS environments. Free Download: Oracle Linux Release 5.6Did you know that by using Oracle Linux 5.5 or 5.6 along with the Unbreakable Enterprise Kernel, you can get all the benefits of Linux mainline kernel 2.6.32 and more, right now, without the need to reinstall or migrate to a new operating system such as RHEL6?Read Release NotesDownload Oracle Linux 5.6 LSB 4.0 Certification Completed for Oracle Linux 5.5Oracle Linux 5.5 with Unbreakable Enterprise Kernel successfully completed the LSB 4.0 certification.  Back to Top WEBCASTS Boost Your Linux Performance with Oracle's Enhancements in Infiniband and RDSRegister to hear Director of Kernel Engineering Chris Mason cover scalability and performance improvements in Linux environment. Get the Facts Oracle's Unbreakable Enterprise KernelSVP Wim Coekaerts and Senior Director Monica Kumar cover the facts about and benefits of using Unbreakable Enterprise Kernel.  View Other Webcasts on Demand   Back to Top EVENTS Collaborate 2011April 10-14 Orlando, Florida Cloud Summit Events, WorldwideVarious dates (check the city for date/time of event) Datacenter Efficiency Events WorldwideThese events include Linux and Oracle VM sessions.Various dates (check the city for date/time of event) Virtualization Events in North America Find an Oracle Event  Back to Top EDUCATION Get Oracle Linux Certified from Oracle University Oracle University offers courses in both Oracle Linux and the administration of Oracle Database on Linux.  Back to Top CUSTOMER SPOTLIGHT Pella Corporation Improves IT Performance and Efficiency with Oracle Linux and Oracle VM To improve IT performance and efficiency and lower operational costs, Pella Corporation, has standardized on Oracle VM and Oracle Linux. Read More Disney Store Deploys POS in 330 Stores and 7 Countries on Oracle Linux Disney Store is running 1,500 registers worldwide on a broad Oracle technology software stack including Oracle Database 11g, Oracle Fusion Middleware, and Oracle Linux. Read More Back to Top PARTNER SPOTLIGHT Emulex and Oracle Announce Data Integrity Features The Unbreakable Enterprise Kernel provides data integrity checking between Oracle Database applications and Emulex 8Gb/s LightPulse Fibre Channel Host Bus Adapters. Read More Dell Inc. Dell Inc. tested and validated configurations support Oracle Linux. Back to Top STAY IN TOUCH Follow @ORCL_Linux on Twitter for the latest penguin tweets Bookmark Oracle.com/Linux Read the Oracle Linux blog Back to Top  Oracle Information InDepth newsletters bring targeted news, articles, customer stories, and special offers to business people who want to find out how to streamline enterprise information management, measure results, improve business processes, and communicate a single truth to their constituents. Please send questions or comments to [email protected]. For answers to questions about subscribing, unsubscribing, and managing your Oracle e-mail communications preferences, please see the Oracle E-Mail Communications page. Copyright © 2011, Oracle Corporation and/or its affiliates. All rights reserved. Oracle is a registered trademark of Oracle Corporation and/or its affiliates. Other names may be trademarks of their respective owners. This document is provided for information purposes only, and the contents hereof are subject to change without notice. This document is not warranted to be error-free, nor is it subject to any other warranties or conditions, whether expressed orally or implied in law, including implied warranties and conditions of merchantability or fitness for a particular purpose. We specifically disclaim any liability with respect to this document, and no contractual obligations are formed either directly or indirectly by this document. This document may not be reproduced or transmitted in any form or by any means, electronic or mechanical, for any purpose, without our prior written permission. 

    Read the article

  • Talend Enterprise Data Integration overperforms on Oracle SPARC T4

    - by Amir Javanshir
    The SPARC T microprocessor, released in 2005 by Sun Microsystems, and now continued at Oracle, has a good track record in parallel execution and multi-threaded performance. However it was less suited for pure single-threaded workloads. The new SPARC T4 processor is now filling that gap by offering a 5x better single-thread performance over previous generations. Following our long-term relationship with Talend, a fast growing ISV positioned by Gartner in the “Visionaries” quadrant of the “Magic Quadrant for Data Integration Tools”, we decided to test some of their integration components with the T4 chip, more precisely on a T4-1 system, in order to verify first hand if this new processor stands up to its promises. Several tests were performed, mainly focused on: Single-thread performance of the new SPARC T4 processor compared to an older SPARC T2+ processor Overall throughput of the SPARC T4-1 server using multiple threads The tests consisted in reading large amounts of data --ten's of gigabytes--, processing and writing them back to a file or an Oracle 11gR2 database table. They are CPU, memory and IO bound tests. Given the main focus of this project --CPU performance--, bottlenecks were removed as much as possible on the memory and IO sub-systems. When possible, the data to process was put into the ZFS filesystem cache, for instance. Also, two external storage devices were directly attached to the servers under test, each one divided in two ZFS pools for read and write operations. Multi-thread: Testing throughput on the Oracle T4-1 The tests were performed with different number of simultaneous threads (1, 2, 4, 8, 12, 16, 32, 48 and 64) and using different storage devices: Flash, Fibre Channel storage, two stripped internal disks and one single internal disk. All storage devices used ZFS as filesystem and volume management. Each thread read a dedicated 1GB-large file containing 12.5M lines with the following structure: customerID;FirstName;LastName;StreetAddress;City;State;Zip;Cust_Status;Since_DT;Status_DT 1;Ronald;Reagan;South Highway;Santa Fe;Montana;98756;A;04-06-2006;09-08-2008 2;Theodore;Roosevelt;Timberlane Drive;Columbus;Louisiana;75677;A;10-05-2009;27-05-2008 3;Andrew;Madison;S Rustle St;Santa Fe;Arkansas;75677;A;29-04-2005;09-02-2008 4;Dwight;Adams;South Roosevelt Drive;Baton Rouge;Vermont;75677;A;15-02-2004;26-01-2007 […] The following graphs present the results of our tests: Unsurprisingly up to 16 threads, all files fit in the ZFS cache a.k.a L2ARC : once the cache is hot there is no performance difference depending on the underlying storage. From 16 threads upwards however, it is clear that IO becomes a bottleneck, having a good IO subsystem is thus key. Single-disk performance collapses whereas the Sun F5100 and ST6180 arrays allow the T4-1 to scale quite seamlessly. From 32 to 64 threads, the performance is almost constant with just a slow decline. For the database load tests, only the best IO configuration --using external storage devices-- were used, hosting the Oracle table spaces and redo log files. Using the Sun Storage F5100 array allows the T4-1 server to scale up to 48 parallel JVM processes before saturating the CPU. The final result is a staggering 646K lines per second insertion in an Oracle table using 48 parallel threads. Single-thread: Testing the single thread performance Seven different tests were performed on both servers. Given the fact that only one thread, thus one file was read, no IO bottleneck was involved, all data being served from the ZFS cache. Read File ? Filter ? Write File: Read file, filter data, write the filtered data in a new file. The filter is set on the “Status” column: only lines with status set to “A” are selected. This limits each output file to about 500 MB. Read File ? Load Database Table: Read file, insert into a single Oracle table. Average: Read file, compute the average of a numeric column, write the result in a new file. Division & Square Root: Read file, perform a division and square root on a numeric column, write the result data in a new file. Oracle DB Dump: Dump the content of an Oracle table (12.5M rows) into a CSV file. Transform: Read file, transform, write the result data in a new file. The transformations applied are: set the address column to upper case and add an extra column at the end, which is the concatenation of two columns. Sort: Read file, sort a numeric and alpha numeric column, write the result data in a new file. The following table and graph present the final results of the tests: Throughput unit is thousand lines per second processed (K lines/second). Improvement is the % of improvement between the T5140 and T4-1. Test T4-1 (Time s.) T5140 (Time s.) Improvement T4-1 (Throughput) T5140 (Throughput) Read/Filter/Write 125 806 645% 100 16 Read/Load Database 195 1111 570% 64 11 Average 96 557 580% 130 22 Division & Square Root 161 1054 655% 78 12 Oracle DB Dump 164 945 576% 76 13 Transform 159 1124 707% 79 11 Sort 251 1336 532% 50 9 The improvement of single-thread performance is quite dramatic: depending on the tests, the T4 is between 5.4 to 7 times faster than the T2+. It seems clear that the SPARC T4 processor has gone a long way filling the gap in single-thread performance, without sacrifying the multi-threaded capability as it still shows a very impressive scaling on heavy-duty multi-threaded jobs. Finally, as always at Oracle ISV Engineering, we are happy to help our ISV partners test their own applications on our platforms, so don't hesitate to contact us and let's see what the SPARC T4-based systems can do for your application! "As describe in this benchmark, Talend Enterprise Data Integration has overperformed on T4. I was generally happy to see that the T4 gave scaling opportunities for many scenarios like complex aggregations. Row by row insertion in Oracle DB is faster with more than 650,000 rows per seconds without using any bulk Oracle capabilities !" Cedric Carbone, Talend CTO.

    Read the article

  • Weighted round robins via TTL - possible?

    - by Joe Hopfgartner
    I currently use DNS round robin for load balancing, which works great. The records look like this (I have a ttl of 120 seconds) ;; ANSWER SECTION: orion.2x.to. 116 IN A 80.237.201.41 orion.2x.to. 116 IN A 87.230.54.12 orion.2x.to. 116 IN A 87.230.100.10 orion.2x.to. 116 IN A 87.230.51.65 I learned that not every ISP / device treats such a response the same way. For example some DNS servers rotate the addresses randomly or always cycle them through. Some just propagate the first entry, others try to determine which is best (regionally near) by looking at the ip address. However if the userbase is big enough (spreads over multiple ISPs etc) it balances pretty well. The discrepancies from highest to lowest loaded server hardly every exceeds 15%. However now I have the problem that I am introducing more servers into the systems, that not all have the same capacities. I currently only have 1gbps servers, but I want to work with 100mbit and also 10gbps servers too. So what I want is I want to introduce a server with 10 GBps with a weight of 100, a 1 gbps server with a weight of 10 and a 100 mbit server with a weight of 1. I used to add servers twice to bring more traffic to them (which worked nice. the bandwidth doubled almost.) But adding a 10gbit server 100 times to DNS is a bit rediculous. So I thought about using the TTL. If I give server A 240 seconds ttl and server B only 120 seconds (which is about about the minimum to use for round robin, as a lot of dns servers set to 120 if a lower ttl is specified.. so i have heard) I think something like this should occour in an ideal scenario: first 120 seconds 50% of requests get server A -> keep it for 240 seconds. 50% of requests get server B -> keep it for 120 seconds second 120 seconds 50% of requests still have server A cached -> keep it for another 120 seconds. 25% of requests get server A -> keep it for 240 seconds 25% of requests get server B -> keep it for 120 seconds third 120 seconds 25% will get server A (from the 50% of Server A that now expired) -> cache 240 sec 25% will get server B (from the 50% of Server A that now expired) -> cache 120 sec 25% will have server A cached for another 120 seconds 12.5% will get server B (from the 25% of server B that now expired) -> cache 120sec 12.5% will get server A (from the 25% of server B that now expired) -> cache 240 sec fourth 120 seconds 25% will have server A cached -> cache for another 120 secs 12.5% will get server A (from the 25% of b that now expired) -> cache 240 secs 12.5% will get server B (from the 25% of b that now expired) -> cache 120 secs 12.5% will get server A (from the 25% of a that now expired) -> cache 240 secs 12.5% will get server B (from the 25% of a that now expired) -> cache 120 secs 6.25% will get server A (from the 12.5% of b that now expired) -> cache 240 secs 6.25% will get server B (from the 12.5% of b that now expired) -> cache 120 secs 12.5% will have server A cached -> cache another 120 secs ... i think i lost something at this point but i think you get the idea.... As you can see this gets pretty complicated to predict and it will for sure not work out like this in practice. But it should definitely have an effect on the distribution! I know that weighted round robin exists and is just controlled by the root server. It just cycles through dns records when responding and returns dns records with a set propability that corresponds to the weighting. My DNS server does not support this, and my requirements are not that precise. If it doesnt weight perfectly its okay, but it should go into the right direction. I think using the TTL field could be a more elegant and easier solution - and it deosnt require a dns server that controls this dynamically, which saves resources - which is in my opinion the whole point of dns load balancing vs hardware load balancers. My question now is... are there any best prectices / methos / rules of thumb to weight round robin distribution using the TTL attribute of DNS records? Edit: The system is a forward proxy server system. The amount of Bandwidth (not requests) exceeds what one single server with ethernet can handle. So I need a balancing solution that distributes the bandwidth to several servers. Are there any alternative methods than using DNS? Of course I can use a load balancer with fibre channel etc, but the costs are rediciulous and it also increases only the width of the bottleneck and does not eliminate it. The only thing i can think of are anycast (is it anycast or multicast?) ip addresses, but I don't have the means to set up such a system.

    Read the article

  • Improving TCP performance over a gigabit network lots of connections and high traffic for storage and streaming services

    - by Linux Guy
    I have two servers, Both servers hardware Specification are Processor : Dual Processor RAM : over 128 G.B Hard disk : SSD Hard disk Outging Traffic bandwidth : 3 Gbps network cards speed : 10 Gbps Server A : for Encoding videos Server B : for storage videos andstream videos over web interface like youtube The inbound bandwidth between two servers is 10Gbps , the outbound bandwidth internet bandwidth is 500Mpbs Both servers using public ip addresses in public and private network Both servers transfer and connection on nginx port , and the server B used for streaming media , like youtube stream videos Both servers in same network , when i do ping from Server A to Server B i got high time latency above 1.0ms , the time range time=52.7 ms to time=215.7 ms - This is the output of iftop utility 353Mb 707Mb 1.04Gb 1.38Gb 1.73Gb mqqqqqqqqqqqqqqqqqqqqqqqqqqqvqqqqqqqqqqqqqqqqqqqqqqqqqqqvqqqqqqqqqqqqqqqqqqqqqqqqqqqvqqqqqqqqqqqqqqqqqqqqqqqqqqqvqqqqqqqqqqqqqqqqqqqqqqqqqqq server.example.com => ip.address 6.36Mb 4.31Mb 1.66Mb <= 158Kb 94.8Kb 35.1Kb server.example.com => ip.address 1.23Mb 4.28Mb 1.12Mb <= 17.1Kb 83.5Kb 21.9Kb server.example.com => ip.address 395Kb 3.89Mb 1.07Mb <= 6.09Kb 109Kb 28.6Kb server.example.com => ip.address 4.55Mb 3.83Mb 1.04Mb <= 55.6Kb 45.4Kb 13.0Kb server.example.com => ip.address 649Kb 3.38Mb 1.47Mb <= 9.00Kb 38.7Kb 16.7Kb server.example.com => ip.address 5.00Mb 3.32Mb 1.80Mb <= 65.7Kb 55.1Kb 29.4Kb server.example.com => ip.address 387Kb 3.13Mb 1.06Mb <= 18.4Kb 39.9Kb 15.0Kb server.example.com => ip.address 3.27Mb 3.11Mb 1.01Mb <= 81.2Kb 64.5Kb 20.9Kb server.example.com => ip.address 1.75Mb 3.08Mb 2.72Mb <= 16.6Kb 35.6Kb 32.5Kb server.example.com => ip.address 1.75Mb 2.90Mb 2.79Mb <= 22.4Kb 32.6Kb 35.6Kb server.example.com => ip.address 3.03Mb 2.78Mb 1.82Mb <= 26.6Kb 27.4Kb 20.2Kb server.example.com => ip.address 2.26Mb 2.66Mb 1.36Mb <= 51.7Kb 49.1Kb 24.4Kb server.example.com => ip.address 586Kb 2.50Mb 1.03Mb <= 4.17Kb 26.1Kb 10.7Kb server.example.com => ip.address 2.42Mb 2.49Mb 2.44Mb <= 31.6Kb 29.7Kb 29.9Kb server.example.com => ip.address 2.41Mb 2.46Mb 2.41Mb <= 26.4Kb 24.5Kb 23.8Kb server.example.com => ip.address 2.37Mb 2.39Mb 2.40Mb <= 28.9Kb 27.0Kb 28.5Kb server.example.com => ip.address 525Kb 2.20Mb 1.05Mb <= 7.03Kb 26.0Kb 12.8Kb qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq TX: cum: 102GB peak: 1.65Gb rates: 1.46Gb 1.44Gb 1.48Gb RX: 1.31GB 24.3Mb 19.5Mb 18.9Mb 20.0Mb TOTAL: 103GB 1.67Gb 1.48Gb 1.46Gb 1.50Gb I check the transfer speed using iperf utility From Server A to Server B # iperf -c 0.0.0.2 -p 8777 ------------------------------------------------------------ Client connecting to 0.0.0.2, TCP port 8777 TCP window size: 85.3 KByte (default) ------------------------------------------------------------ [ 3] local 0.0.0.1 port 38895 connected with 0.0.0.2 port 8777 [ ID] Interval Transfer Bandwidth [ 3] 0.0-10.8 sec 528 KBytes 399 Kbits/sec My Current Connections in Server B # netstat -an|grep ":8777"|awk '/tcp/ {print $6}'|sort -nr| uniq -c 2072 TIME_WAIT 28 SYN_RECV 1 LISTEN 189 LAST_ACK 139 FIN_WAIT2 373 FIN_WAIT1 3381 ESTABLISHED 34 CLOSING Server A Network Card Information Settings for eth0: Supported ports: [ TP ] Supported link modes: 100baseT/Full 1000baseT/Full 10000baseT/Full Supported pause frame use: No Supports auto-negotiation: Yes Advertised link modes: 10000baseT/Full Advertised pause frame use: No Advertised auto-negotiation: Yes Speed: 10000Mb/s Duplex: Full Port: Twisted Pair PHYAD: 0 Transceiver: external Auto-negotiation: on MDI-X: Unknown Supports Wake-on: d Wake-on: d Current message level: 0x00000007 (7) drv probe link Link detected: yes Server B Network Card Information Settings for eth2: Supported ports: [ FIBRE ] Supported link modes: 10000baseT/Full Supported pause frame use: No Supports auto-negotiation: No Advertised link modes: 10000baseT/Full Advertised pause frame use: No Advertised auto-negotiation: No Speed: 10000Mb/s Duplex: Full Port: Direct Attach Copper PHYAD: 0 Transceiver: external Auto-negotiation: off Supports Wake-on: d Wake-on: d Current message level: 0x00000007 (7) drv probe link Link detected: yes ifconfig server A eth0 Link encap:Ethernet HWaddr 00:25:90:ED:9E:AA inet addr:0.0.0.1 Bcast:0.0.0.255 Mask:255.255.255.0 UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1 RX packets:1202795665 errors:0 dropped:64334 overruns:0 frame:0 TX packets:2313161968 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:1000 RX bytes:893413096188 (832.0 GiB) TX bytes:3360949570454 (3.0 TiB) lo Link encap:Local Loopback inet addr:127.0.0.1 Mask:255.0.0.0 inet6 addr: ::1/128 Scope:Host UP LOOPBACK RUNNING MTU:65536 Metric:1 RX packets:2207544 errors:0 dropped:0 overruns:0 frame:0 TX packets:2207544 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:0 RX bytes:247769175 (236.2 MiB) TX bytes:247769175 (236.2 MiB) ifconfig Server B eth2 Link encap:Ethernet HWaddr 00:25:90:82:C4:FE inet addr:0.0.0.2 Bcast:0.0.0.2 Mask:255.255.255.0 UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1 RX packets:39973046980 errors:0 dropped:1828387600 overruns:0 frame:0 TX packets:69618752480 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:1000 RX bytes:3013976063688 (2.7 TiB) TX bytes:102250230803933 (92.9 TiB) lo Link encap:Local Loopback inet addr:127.0.0.1 Mask:255.0.0.0 inet6 addr: ::1/128 Scope:Host UP LOOPBACK RUNNING MTU:65536 Metric:1 RX packets:1049495 errors:0 dropped:0 overruns:0 frame:0 TX packets:1049495 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:0 RX bytes:129012422 (123.0 MiB) TX bytes:129012422 (123.0 MiB) Netstat -i on Server B # netstat -i Kernel Interface table Iface MTU Met RX-OK RX-ERR RX-DRP RX-OVR TX-OK TX-ERR TX-DRP TX-OVR Flg eth2 9000 0 42098629968 0 2131223717 0 73698797854 0 0 0 BMRU lo 65536 0 1077908 0 0 0 1077908 0 0 0 LRU I Turn up send/receive buffers on the network card to 2048 and problem still persist I increase the MTU for server A and problem still persist and i increase the MTU for server B for better connectivity and transfer speed but it couldn't transfer at all The problem is : as you can see from iperf utility, the transfer speed from server A to server B slow when i restart network service in server B the transfer in server A at full speed, after 2 minutes , it's getting slow How could i troubleshoot slow speed issue and fix it in server B ? Notice : if there any other commands i should execute in servers for more information, so it might help resolve the problem , let me know in comments

    Read the article

  • help with fixing fwts errors log

    - by jasmines
    Here is an extract of results.log: MTRR validation. Test 1 of 3: Validate the kernel MTRR IOMEM setup. FAILED [MEDIUM] MTRRIncorrectAttr: Test 1, Memory range 0xc0000000 to 0xdfffffff (PCI Bus 0000:00) has incorrect attribute Write-Combining. FAILED [MEDIUM] MTRRIncorrectAttr: Test 1, Memory range 0xfee01000 to 0xffffffff (PCI Bus 0000:00) has incorrect attribute Write-Protect. ==================================================================================================== Test 1 of 1: Kernel log error check. Kernel message: [ 0.208079] [Firmware Bug]: ACPI: BIOS _OSI(Linux) query ignored ADVICE: This is not exactly a failure mode but a warning from the kernel. The _OSI() method has implemented a match to the 'Linux' query in the DSDT and this is redundant because the ACPI driver matches onto the Windows _OSI strings by default. FAILED [HIGH] KlogACPIErrorMethodExecutionParse: Test 1, HIGH Kernel message: [ 3.512783] ACPI Error : Method parse/execution failed [\_SB_.PCI0.GFX0._DOD] (Node f7425858), AE_AML_PACKAGE_LIMIT (20110623/psparse-536) ADVICE: This is a bug picked up by the kernel, but as yet, the firmware test suite has no diagnostic advice for this particular problem. Found 1 unique errors in kernel log. ==================================================================================================== Check if system is using latest microcode. ---------------------------------------------------------------------------------------------------- Cannot read microcode file /usr/share/misc/intel-microcode.dat. Aborted test, initialisation failed. ==================================================================================================== MSR register tests. FAILED [MEDIUM] MSRCPUsInconsistent: Test 1, MSR SYSENTER_ESP (0x175) has 1 inconsistent values across 2 CPUs for (shift: 0 mask: 0xffffffffffffffff). MSR CPU 0 -> 0xf7bb9c40 vs CPU 1 -> 0xf7bc7c40 FAILED [MEDIUM] MSRCPUsInconsistent: Test 1, MSR MISC_ENABLE (0x1a0) has 1 inconsistent values across 2 CPUs for (shift: 0 mask: 0x400c51889). MSR CPU 0 -> 0x850088 vs CPU 1 -> 0x850089 ==================================================================================================== Checks firmware has set PCI Express MaxReadReq to a higher value on non-motherboard devices. ---------------------------------------------------------------------------------------------------- Test 1 of 1: Check firmware settings MaxReadReq for PCI Express devices. MaxReadReq for pci://00:00:1b.0 Audio device: Intel Corporation 82801I (ICH9 Family) HD Audio Controller (rev 03) is low (128) [Audio device]. MaxReadReq for pci://00:02:00.0 Network controller: Intel Corporation PRO/Wireless 5100 AGN [Shiloh] Network Connection is low (128) [Network controller]. FAILED [LOW] LowMaxReadReq: Test 1, 2 devices have low MaxReadReq settings. Firmware may have configured these too low. ADVICE: The MaxReadRequest size is set too low and will affect performance. It will provide excellent bus sharing at the cost of bus data transfer rates. Although not a critical issue, it may be worth considering setting the MaxReadRequest size to 256 or 512 to increase throughput on the PCI Express bus. Some drivers (for example the Brocade Fibre Channel driver) allow one to override the firmware settings. Where possible, this BIOS configuration setting is worth increasing it a little more for better performance at a small reduction of bus sharing. ==================================================================================================== PCIe ASPM check. ---------------------------------------------------------------------------------------------------- Test 1 of 2: PCIe ASPM ACPI test. PCIE ASPM is not controlled by Linux kernel. ADVICE: BIOS reports that Linux kernel should not modify ASPM settings that BIOS configured. It can be intentional because hardware vendors identified some capability bugs between the motherboard and the add-on cards. Test 2 of 2: PCIe ASPM registers test. WARNING: Test 2, RP 00h:1Ch.01h L0s not enabled. WARNING: Test 2, RP 00h:1Ch.01h L1 not enabled. WARNING: Test 2, Device 02h:00h.00h L0s not enabled. WARNING: Test 2, Device 02h:00h.00h L1 not enabled. PASSED: Test 2, PCIE aspm setting matched was matched. WARNING: Test 2, RP 00h:1Ch.05h L0s not enabled. WARNING: Test 2, RP 00h:1Ch.05h L1 not enabled. WARNING: Test 2, Device 85h:00h.00h L0s not enabled. WARNING: Test 2, Device 85h:00h.00h L1 not enabled. PASSED: Test 2, PCIE aspm setting matched was matched. ==================================================================================================== Extract and analyse Windows Management Instrumentation (WMI). Test 1 of 2: Check Windows Management Instrumentation in DSDT Found WMI Method WMAA with GUID: 5FB7F034-2C63-45E9-BE91-3D44E2C707E4, Instance 0x01 Found WMI Event, Notifier ID: 0x80, GUID: 95F24279-4D7B-4334-9387-ACCDC67EF61C, Instance 0x01 PASSED: Test 1, GUID 95F24279-4D7B-4334-9387-ACCDC67EF61C is handled by driver hp-wmi (Vendor: HP). Found WMI Event, Notifier ID: 0xa0, GUID: 2B814318-4BE8-4707-9D84-A190A859B5D0, Instance 0x01 FAILED [MEDIUM] WMIUnknownGUID: Test 1, GUID 2B814318-4BE8-4707-9D84-A190A859B5D0 is unknown to the kernel, a driver may need to be implemented for this GUID. ADVICE: A WMI driver probably needs to be written for this event. It can checked for using: wmi_has_guid("2B814318-4BE8-4707-9D84-A190A859B5D0"). One can install a notify handler using wmi_install_notify_handler("2B814318-4BE8-4707-9D84-A190A859B5D0", handler, NULL). http://lwn.net/Articles/391230 describes how to write an appropriate driver. Found WMI Object, Object ID AB, GUID: 05901221-D566-11D1-B2F0-00A0C9062910, Instance 0x01, Flags: 00 Found WMI Method WMBA with GUID: 1F4C91EB-DC5C-460B-951D-C7CB9B4B8D5E, Instance 0x01 Found WMI Object, Object ID BC, GUID: 2D114B49-2DFB-4130-B8FE-4A3C09E75133, Instance 0x7f, Flags: 00 Found WMI Object, Object ID BD, GUID: 988D08E3-68F4-4C35-AF3E-6A1B8106F83C, Instance 0x19, Flags: 00 Found WMI Object, Object ID BE, GUID: 14EA9746-CE1F-4098-A0E0-7045CB4DA745, Instance 0x01, Flags: 00 Found WMI Object, Object ID BF, GUID: 322F2028-0F84-4901-988E-015176049E2D, Instance 0x01, Flags: 00 Found WMI Object, Object ID BG, GUID: 8232DE3D-663D-4327-A8F4-E293ADB9BF05, Instance 0x01, Flags: 00 Found WMI Object, Object ID BH, GUID: 8F1F6436-9F42-42C8-BADC-0E9424F20C9A, Instance 0x00, Flags: 00 Found WMI Object, Object ID BI, GUID: 8F1F6435-9F42-42C8-BADC-0E9424F20C9A, Instance 0x00, Flags: 00 Found WMI Method WMAC with GUID: 7391A661-223A-47DB-A77A-7BE84C60822D, Instance 0x01 Found WMI Object, Object ID BJ, GUID: DF4E63B6-3BBC-4858-9737-C74F82F821F3, Instance 0x05, Flags: 00 ==================================================================================================== Disassemble DSDT to check for _OSI("Linux"). ---------------------------------------------------------------------------------------------------- Test 1 of 1: Disassemble DSDT to check for _OSI("Linux"). This is not strictly a failure mode, it just alerts one that this has been defined in the DSDT and probably should be avoided since the Linux ACPI driver matches onto the Windows _OSI strings { If (_OSI ("Linux")) { Store (0x03E8, OSYS) } If (_OSI ("Windows 2001")) { Store (0x07D1, OSYS) } If (_OSI ("Windows 2001 SP1")) { Store (0x07D1, OSYS) } If (_OSI ("Windows 2001 SP2")) { Store (0x07D2, OSYS) } If (_OSI ("Windows 2006")) { Store (0x07D6, OSYS) } If (LAnd (MPEN, LEqual (OSYS, 0x07D1))) { TRAP (0x01, 0x48) } TRAP (0x03, 0x35) } WARNING: Test 1, DSDT implements a deprecated _OSI("Linux") test. ==================================================================================================== 0 passed, 0 failed, 1 warnings, 0 aborted, 0 skipped, 0 info only. ==================================================================================================== ACPI DSDT Method Semantic Tests. ACPICA Exception AE_AML_INFINITE_LOOP during execution of method COMP Failed to install global event handler. Test 22 of 93: Check _PSR (Power Source). ACPICA Exception AE_AML_INFINITE_LOOP during execution of method COMP WARNING: Test 22, Detected an infinite loop when evaluating method '\_SB_.AC__._PSR'. ADVICE: This may occur because we are emulating the execution in this test environment and cannot handshake with the embedded controller or jump to the BIOS via SMIs. However, the fact that AML code spins forever means that lockup conditions are not being checked for in the AML bytecode. PASSED: Test 22, \_SB_.AC__._PSR correctly acquired and released locks 16 times. Test 35 of 93: Check _TMP (Thermal Zone Current Temp). ACPICA Exception AE_AML_INFINITE_LOOP during execution of method COMP WARNING: Test 35, Detected an infinite loop when evaluating method '\_TZ_.DTSZ._TMP'. ADVICE: This may occur because we are emulating the execution in this test environment and cannot handshake with the embedded controller or jump to the BIOS via SMIs. However, the fact that AML code spins forever means that lockup conditions are not being checked for in the AML bytecode. PASSED: Test 35, \_TZ_.DTSZ._TMP correctly acquired and released locks 14 times. ACPICA Exception AE_AML_INFINITE_LOOP during execution of method COMP WARNING: Test 35, Detected an infinite loop when evaluating method '\_TZ_.CPUZ._TMP'. ADVICE: This may occur because we are emulating the execution in this test environment and cannot handshake with the embedded controller or jump to the BIOS via SMIs. However, the fact that AML code spins forever means that lockup conditions are not being checked for in the AML bytecode. PASSED: Test 35, \_TZ_.CPUZ._TMP correctly acquired and released locks 10 times. ACPICA Exception AE_AML_INFINITE_LOOP during execution of method COMP WARNING: Test 35, Detected an infinite loop when evaluating method '\_TZ_.SKNZ._TMP'. ADVICE: This may occur because we are emulating the execution in this test environment and cannot handshake with the embedded controller or jump to the BIOS via SMIs. However, the fact that AML code spins forever means that lockup conditions are not being checked for in the AML bytecode. PASSED: Test 35, \_TZ_.SKNZ._TMP correctly acquired and released locks 10 times. PASSED: Test 35, _TMP correctly returned sane looking value 0x00000b4c (289.2 degrees K) PASSED: Test 35, \_TZ_.BATZ._TMP correctly acquired and released locks 9 times. PASSED: Test 35, _TMP correctly returned sane looking value 0x00000aac (273.2 degrees K) PASSED: Test 35, \_TZ_.FDTZ._TMP correctly acquired and released locks 7 times. Test 46 of 93: Check _DIS (Disable). FAILED [MEDIUM] MethodShouldReturnNothing: Test 46, \_SB_.PCI0.LPCB.SIO_.COM1._DIS returned values, but was expected to return nothing. Object returned: INTEGER: 0x00000000 ADVICE: This probably won't cause any errors, but it should be fixed as the AML code is not conforming to the expected behaviour as described in the ACPI specification. FAILED [MEDIUM] MethodShouldReturnNothing: Test 46, \_SB_.PCI0.LPCB.SIO_.LPT0._DIS returned values, but was expected to return nothing. Object returned: INTEGER: 0x00000000 ADVICE: This probably won't cause any errors, but it should be fixed as the AML code is not conforming to the expected behaviour as described in the ACPI specification. Test 61 of 93: Check _WAK (System Wake). Test _WAK(1) System Wake, State S1. ACPICA Exception AE_AML_INFINITE_LOOP during execution of method COMP WARNING: Test 61, Detected an infinite loop when evaluating method '\_WAK'. ADVICE: This may occur because we are emulating the execution in this test environment and cannot handshake with the embedded controller or jump to the BIOS via SMIs. However, the fact that AML code spins forever means that lockup conditions are not being checked for in the AML bytecode. Test _WAK(2) System Wake, State S2. ACPICA Exception AE_AML_INFINITE_LOOP during execution of method COMP WARNING: Test 61, Detected an infinite loop when evaluating method '\_WAK'. ADVICE: This may occur because we are emulating the execution in this test environment and cannot handshake with the embedded controller or jump to the BIOS via SMIs. However, the fact that AML code spins forever means that lockup conditions are not being checked for in the AML bytecode. Test _WAK(3) System Wake, State S3. ACPICA Exception AE_AML_INFINITE_LOOP during execution of method COMP WARNING: Test 61, Detected an infinite loop when evaluating method '\_WAK'. ADVICE: This may occur because we are emulating the execution in this test environment and cannot handshake with the embedded controller or jump to the BIOS via SMIs. However, the fact that AML code spins forever means that lockup conditions are not being checked for in the AML bytecode. Test _WAK(4) System Wake, State S4. ACPICA Exception AE_AML_INFINITE_LOOP during execution of method COMP WARNING: Test 61, Detected an infinite loop when evaluating method '\_WAK'. ADVICE: This may occur because we are emulating the execution in this test environment and cannot handshake with the embedded controller or jump to the BIOS via SMIs. However, the fact that AML code spins forever means that lockup conditions are not being checked for in the AML bytecode. Test _WAK(5) System Wake, State S5. ACPICA Exception AE_AML_INFINITE_LOOP during execution of method COMP WARNING: Test 61, Detected an infinite loop when evaluating method '\_WAK'. ADVICE: This may occur because we are emulating the execution in this test environment and cannot handshake with the embedded controller or jump to the BIOS via SMIs. However, the fact that AML code spins forever means that lockup conditions are not being checked for in the AML bytecode. Test 87 of 93: Check _BCL (Query List of Brightness Control Levels Supported). Package has 2 elements: 00: INTEGER: 0x00000000 01: INTEGER: 0x00000000 FAILED [MEDIUM] Method_BCLElementCount: Test 87, Method _BCL should return a package of more than 2 integers, got just 2. Test 88 of 93: Check _BCM (Set Brightness Level). ACPICA Exception AE_AML_PACKAGE_LIMIT during execution of method _BCM FAILED [CRITICAL] AEAMLPackgeLimit: Test 88, Detected error 'Package limit' when evaluating '\_SB_.PCI0.GFX0.DD02._BCM'. ==================================================================================================== ACPI table settings sanity checks. ---------------------------------------------------------------------------------------------------- Test 1 of 1: Check ACPI tables. PASSED: Test 1, Table APIC passed. Table ECDT not present to check. FAILED [MEDIUM] FADT32And64BothDefined: Test 1, FADT 32 bit FIRMWARE_CONTROL is non-zero, and X_FIRMWARE_CONTROL is also non-zero. Section 5.2.9 of the ACPI specification states that if the FIRMWARE_CONTROL is non-zero then X_FIRMWARE_CONTROL must be set to zero. ADVICE: The FADT FIRMWARE_CTRL is a 32 bit pointer that points to the physical memory address of the Firmware ACPI Control Structure (FACS). There is also an extended 64 bit version of this, the X_FIRMWARE_CTRL pointer that also can point to the FACS. Section 5.2.9 of the ACPI specification states that if the X_FIRMWARE_CTRL field contains a non zero value then the FIRMWARE_CTRL field *must* be zero. This error is also detected by the Linux kernel. If FIRMWARE_CTRL and X_FIRMWARE_CTRL are defined, then the kernel just uses the 64 bit version of the pointer. PASSED: Test 1, Table HPET passed. PASSED: Test 1, Table MCFG passed. PASSED: Test 1, Table RSDT passed. PASSED: Test 1, Table RSDP passed. Table SBST not present to check. PASSED: Test 1, Table XSDT passed. ==================================================================================================== Re-assemble DSDT and find syntax errors and warnings. ---------------------------------------------------------------------------------------------------- Test 1 of 2: Disassemble and reassemble DSDT FAILED [HIGH] AMLAssemblerError4043: Test 1, Assembler error in line 2261 Line | AML source ---------------------------------------------------------------------------------------------------- 02258| 0x00000000, // Range Minimum 02259| 0xFEDFFFFF, // Range Maximum 02260| 0x00000000, // Translation Offset 02261| 0x00000000, // Length | ^ | error 4043: Invalid combination of Length and Min/Max fixed flags 02262| ,, _Y0E, AddressRangeMemory, TypeStatic) 02263| DWordMemory (ResourceProducer, PosDecode, MinFixed, MaxFixed, Cacheable, ReadWrite, 02264| 0x00000000, // Granularity ==================================================================================================== ADVICE: (for error #4043): This occurs if the length is zero and just one of the resource MIF/MAF flags are set, or the length is non-zero and resource MIF/MAF flags are both set. These are illegal combinations and need to be fixed. See section 6.4.3.5 Address Space Resource Descriptors of version 4.0a of the ACPI specification for more details. FAILED [HIGH] AMLAssemblerError4050: Test 1, Assembler error in line 2268 Line | AML source ---------------------------------------------------------------------------------------------------- 02265| 0xFEE01000, // Range Minimum 02266| 0xFFFFFFFF, // Range Maximum 02267| 0x00000000, // Translation Offset 02268| 0x011FEFFF, // Length | ^ | error 4050: Length is not equal to fixed Min/Max window 02269| ,, , AddressRangeMemory, TypeStatic) 02270| }) 02271| Method (_CRS, 0, Serialized) ==================================================================================================== ADVICE: (for error #4050): The minimum address is greater than the maximum address. This is illegal. FAILED [HIGH] AMLAssemblerError1104: Test 1, Assembler error in line 8885 Line | AML source ---------------------------------------------------------------------------------------------------- 08882| Method (_DIS, 0, NotSerialized) 08883| { 08884| DSOD (0x02) 08885| Return (0x00) | ^ | warning level 0 1104: Reserved method should not return a value (_DIS) 08886| } 08887| 08888| Method (_SRS, 1, NotSerialized) ==================================================================================================== FAILED [HIGH] AMLAssemblerError1104: Test 1, Assembler error in line 9195 Line | AML source ---------------------------------------------------------------------------------------------------- 09192| Method (_DIS, 0, NotSerialized) 09193| { 09194| DSOD (0x01) 09195| Return (0x00) | ^ | warning level 0 1104: Reserved method should not return a value (_DIS) 09196| } 09197| 09198| Method (_SRS, 1, NotSerialized) ==================================================================================================== FAILED [HIGH] AMLAssemblerError1127: Test 1, Assembler error in line 9242 Line | AML source ---------------------------------------------------------------------------------------------------- 09239| CreateWordField (CRES, \_SB.PCI0.LPCB.SIO.LPT0._CRS._Y21._MAX, MAX2) 09240| CreateByteField (CRES, \_SB.PCI0.LPCB.SIO.LPT0._CRS._Y21._LEN, LEN2) 09241| CreateWordField (CRES, \_SB.PCI0.LPCB.SIO.LPT0._CRS._Y22._INT, IRQ0) 09242| CreateWordField (CRES, \_SB.PCI0.LPCB.SIO.LPT0._CRS._Y23._DMA, DMA0) | ^ | warning level 0 1127: ResourceTag smaller than Field (Tag: 8 bits, Field: 16 bits) 09243| If (RLPD) 09244| { 09245| Store (0x00, Local0) ==================================================================================================== FAILED [HIGH] AMLAssemblerError1128: Test 1, Assembler error in line 18682 Line | AML source ---------------------------------------------------------------------------------------------------- 18679| Store (0x01, Index (DerefOf (Index (Local0, 0x02)), 0x01)) 18680| If (And (WDPE, 0x40)) 18681| { 18682| Wait (\_SB.BEVT, 0x10) | ^ | warning level 0 1128: Result is not used, possible operator timeout will be missed 18683| } 18684| 18685| Store (BRID, Index (DerefOf (Index (Local0, 0x02)), 0x02)) ==================================================================================================== ADVICE: (for warning level 0 #1128): The operation can possibly timeout, and hence the return value indicates an timeout error. However, because the return value is not checked this very probably indicates that the code is buggy. A possible scenario is that a mutex times out and the code attempts to access data in a critical region when it should not. This will lead to undefined behaviour. This should be fixed. Table DSDT (0) reassembly: Found 2 errors, 4 warnings. Test 2 of 2: Disassemble and reassemble SSDT PASSED: Test 2, SSDT (0) reassembly, Found 0 errors, 0 warnings. FAILED [HIGH] AMLAssemblerError1104: Test 2, Assembler error in line 60 Line | AML source ---------------------------------------------------------------------------------------------------- 00057| { 00058| Store (CPDC (Arg0), Local0) 00059| GCAP (Local0) 00060| Return (Local0) | ^ | warning level 0 1104: Reserved method should not return a value (_PDC) 00061| } 00062| 00063| Method (_OSC, 4, NotSerialized) ==================================================================================================== FAILED [HIGH] AMLAssemblerError1104: Test 2, Assembler error in line 174 Line | AML source ---------------------------------------------------------------------------------------------------- 00171| { 00172| Store (\_PR.CPU0.CPDC (Arg0), Local0) 00173| GCAP (Local0) 00174| Return (Local0) | ^ | warning level 0 1104: Reserved method should not return a value (_PDC) 00175| } 00176| 00177| Method (_OSC, 4, NotSerialized) ==================================================================================================== FAILED [HIGH] AMLAssemblerError1104: Test 2, Assembler error in line 244 Line | AML source ---------------------------------------------------------------------------------------------------- 00241| { 00242| Store (\_PR.CPU0.CPDC (Arg0), Local0) 00243| GCAP (Local0) 00244| Return (Local0) | ^ | warning level 0 1104: Reserved method should not return a value (_PDC) 00245| } 00246| 00247| Method (_OSC, 4, NotSerialized) ==================================================================================================== FAILED [HIGH] AMLAssemblerError1104: Test 2, Assembler error in line 290 Line | AML source ---------------------------------------------------------------------------------------------------- 00287| { 00288| Store (\_PR.CPU0.CPDC (Arg0), Local0) 00289| GCAP (Local0) 00290| Return (Local0) | ^ | warning level 0 1104: Reserved method should not return a value (_PDC) 00291| } 00292| 00293| Method (_OSC, 4, NotSerialized) ==================================================================================================== Table SSDT (1) reassembly: Found 0 errors, 4 warnings. PASSED: Test 2, SSDT (2) reassembly, Found 0 errors, 0 warnings. PASSED: Test 2, SSDT (3) reassembly, Found 0 errors, 0 warnings. ==================================================================================================== 3 passed, 10 failed, 0 warnings, 0 aborted, 0 skipped, 0 info only. ==================================================================================================== Critical failures: 1 method test, at 1 log line: 1449: Detected error 'Package limit' when evaluating '\_SB_.PCI0.GFX0.DD02._BCM'. High failures: 11 klog test, at 1 log line: 121: HIGH Kernel message: [ 3.512783] ACPI Error: Method parse/execution failed [\_SB_.PCI0.GFX0._DOD] (Node f7425858), AE_AML_PACKAGE_LIMIT (20110623/psparse-536) syntaxcheck test, at 1 log line: 1668: Assembler error in line 2261 syntaxcheck test, at 1 log line: 1687: Assembler error in line 2268 syntaxcheck test, at 1 log line: 1703: Assembler error in line 8885 syntaxcheck test, at 1 log line: 1716: Assembler error in line 9195 syntaxcheck test, at 1 log line: 1729: Assembler error in line 9242 syntaxcheck test, at 1 log line: 1742: Assembler error in line 18682 syntaxcheck test, at 1 log line: 1766: Assembler error in line 60 syntaxcheck test, at 1 log line: 1779: Assembler error in line 174 syntaxcheck test, at 1 log line: 1792: Assembler error in line 244 syntaxcheck test, at 1 log line: 1805: Assembler error in line 290 Medium failures: 9 mtrr test, at 1 log line: 76: Memory range 0xc0000000 to 0xdfffffff (PCI Bus 0000:00) has incorrect attribute Write-Combining. mtrr test, at 1 log line: 78: Memory range 0xfee01000 to 0xffffffff (PCI Bus 0000:00) has incorrect attribute Write-Protect. msr test, at 1 log line: 165: MSR SYSENTER_ESP (0x175) has 1 inconsistent values across 2 CPUs for (shift: 0 mask: 0xffffffffffffffff). msr test, at 1 log line: 173: MSR MISC_ENABLE (0x1a0) has 1 inconsistent values across 2 CPUs for (shift: 0 mask: 0x400c51889). wmi test, at 1 log line: 528: GUID 2B814318-4BE8-4707-9D84-A190A859B5D0 is unknown to the kernel, a driver may need to be implemented for this GUID. method test, at 1 log line: 1002: \_SB_.PCI0.LPCB.SIO_.COM1._DIS returned values, but was expected to return nothing. method test, at 1 log line: 1011: \_SB_.PCI0.LPCB.SIO_.LPT0._DIS returned values, but was expected to return nothing. method test, at 1 log line: 1443: Method _BCL should return a package of more than 2 integers, got just 2. acpitables test, at 1 log line: 1643: FADT 32 bit FIRMWARE_CONTROL is non-zero, and X_FIRMWARE_CONTROL is also non-zero. Se

    Read the article

  • Cluster Node Recovery Using Second Node in Solaris Cluster

    - by Onur Bingul
    Assumptions:Node 0a is the cluster node that has crashed and could not boot anymore.Node 0b is the node in cluster and in production with services active.Both nodes have their boot disk mirrored via SDS/SVM.We have many options to clone the boot disk from node 0b:- make a copy via network using the ufsdump command and pipe to ufsrestore - make a copy inserting the disk locally on node 0b and creating the third mirror with SDS- make a copy inserting the disk locally on node 0b using dd commandIn this procedure we are going to use dd command (from my experience this is the best option).Bare in mind that in the examples provided we work on Sun Fire V240 systems which have SCSI internal disks. In the case of Fibre Channel (FC) internal disks you must pay attention to the unique identifier, or World Wide Name (WWN), associated with each FC disk (in this case take a look at infodoc #40133 in order to recreate the device tree correctly).Procedure:On node 0b the boot disk is c1t0d0 (c1t1d0 mirror) and this is the VTOC:* Partition  Tag  Flags    Sector     Count    Sector  Mount Directory      0      2    00          0   2106432   2106431      1      3    01    2106432  74630784  76737215      2      5    00          0 143349312 143349311      4      7    00   76737216  50340672 127077887      5      4    00  127077888  14683968 141761855      6      0    00  141761856   1058304 142820159      7      0    00  142820160    529152 143349311We will insert the new disk on node 0b and it will be seen as c1t2d0.1) On node 0b we make a copy via dd from disk c1t0d0s2 to disk c1t2d0s2# dd if=/dev/rdsk/c1t0d0s2 of=/dev/rdsk/c1t2d0s2 bs=8192kA copy of a 72GB disk will take approximately about 45 minutes.Note: as an alternative to make identical copy of root over network follow Document ID: 47498Title: Sun[TM] Cluster 3.0: How to Rebuild a node with Veritas Volume Manager2) Perform an fsck on disk c1t2d0 data slices:   1.  fsck -o f /dev/rdsk/c1t2d0s0 (root)   2.  fsck -o f /dev/rdsk/c1t2d0s4 (/var)   3.  fsck -o f /dev/rdsk/c1t2d0s5 (/usr)   4.  fsck -o f /dev/rdsk/c1t2d0s6 (/globaldevices)3) Mount the root file system in order to edit following files for changing the node name:# mount /dev/dsk/c1t2d0s0 /mntChange the hostname from 0b to 0a:# cd /mnt/etc# vi hosts # vi hostname.bge0 # vi hostname.bge2 # vi nodename 4) Change the /mnt/etc/vfstab from the actual:/dev/md/dsk/d201        -       -       swap    -       no      -/dev/md/dsk/d200        /dev/md/rdsk/d200       /       ufs     1       no      -/dev/md/dsk/d205        /dev/md/rdsk/d205       /usr    ufs     1       no      logging/dev/md/dsk/d204        /dev/md/rdsk/d204       /var    ufs     1       no      logging#/dev/md/dsk/d206       /dev/md/rdsk/d206       /globaldevices  ufs     2       yes     loggingswap    -       /tmp    tmpfs   -       yes     -/dev/md/dsk/d206        /dev/md/rdsk/d206       /global/.devices/node@2 ufs     2       noglobalto this (unencapsulate disk from SDS/SVM):/dev/dsk/c1t0d0s1        -       -       swap    -       no      -/dev/dsk/c1t0d0s0       /dev/rdsk/c1t0d0s0       /       ufs     1       no      -/dev/dsk/c1t0d0s5       /dev/rdsk/c1t0d0s5       /usr    ufs     1       no      logging/dev/dsk/c1t0d0s4       /dev/rdsk/c1t0d0s4       /var    ufs     1       no      logging#/dev/md/dsk/d206       /dev/md/rdsk/d206       /globaldevices  ufs     2       yes     loggingswap    -       /tmp    tmpfs   -       yes     -/dev/dsk/c1t0d0s6       /dev/rdsk/c1t0d0s6       /global/.devices/node@1 ufs     2       no globalIt is important that global device partition (slice 6) in the new vfstab will point to the physical partition of the disk (in our case slice 6).Be careful with the name you use for the new disk. In this case we define it as c1t0d0 because we will insert it as target 0 in node 0a.But this could be different based on the configuration you are working on.5) Remove following entry from /mnt/etc/system (part of unencapsulation procedure):rootdev:/pseudo/md@0:0,200,blk6) Correct the link shared -> ../../global/.devices/node@2/dev/md/shared in order to point to the nodeid of node 0a (in our case nodeid 1):# cd /mnt/dev/mdhow it is now.... node 0b has nodeid 2lrwxrwxrwx   1 root     root          42 Mar 10  2005 shared ->../../global/.devices/node@2/dev/md/shared# rm shared# ln -s ../../global/.devices/node@1/dev/md/shared sharedhow is going to be... with nodeid 1 for node 0alrwxrwxrwx   1 root     root          42 Mar 10  2005 shared ->../../global/.devices/node@1/dev/md/shared7) Change nodeid (in our case from 2 to 1):# cd /mnt/etc/cluster# vi nodeid8) Change the file /mnt/etc/path_to_inst in order to reflect the correct nodeid for node 0a:# cd /mnt/etc# vi path_to_instChange entries from node@2 to node@1 with the vi command ":%s/node@2/node@1/g"9) Write the bootblock to the disk... just in case:# /usr/sbin/installboot /usr/platform/sun4u/lib/fs/ufs/bootblk /dev/rdsk/c1t2d0s0Now the disk is ready to be inserted in node 0a in order to bootup the node.10) Bootup node 0a with command "boot -sx"... this is becasue we need to make some changes in ccr files in order to recreate did environment.11) Modify cluster ccr:# cd /etc/cluster/ccr# rm did_instances# rm did_instances.bak# vi directory - remove the did_instances line.# /usr/cluster/lib/sc/ccradm -i /etc/cluster/ccr/directory # grep ccr_gennum /etc/cluster/ccr/directory ccr_gennum -1 # /usr/cluster/lib/sc/ccradm -i /etc/cluster/ccr/infrastructure # grep ccr_gennum /etc/cluster/ccr/infrastructure ccr_gennum -112) Bring the node 0a down again to the ok prompt and then issue the command "boot -r"Now the node will join the cluster and from scstat and metaset command you can verify functionality. Next step is to encapsulate the boot disk in SDS/SVM and create the mirrors.In our case node 0b has metadevice name starting from d200. For this reason on node 0a we need to create metadevice starting from d100. This is just an example, you can have different names.The important thing to remember is that metadevice boot disks have different names on each node.13) Remove metadevice pointing to the boot and mirror disks (inherit from node 0b):# metaclear -r -f d200# metaclear -r -f d201# metaclear -r -f d204# metaclear -r -f d205# metaclear -r -f d206verify from metastat that no metadevices are set for boot and mirror disks.14) Encapsulate the boot disk:# metainit -f d110 1 1 c1t0d0s0# metainit d100 -m d110# metaroot d10015) Reboot node 0a.16) Create all the metadevice for slices remaining on boot disk# metainit -f d111 1 1 c1t0d0s1# metainit d101 -m d111# metainit -f d114 1 1 c1t0d0s4# metainit d104 -m d114# metainit -f d115 1 1 c1t0d0s5# metainit d105 -m d115# metainit -f d116 1 1 c1t0d0s6# metainit d106 -m d11617) Edit the vfstab in order to specifiy metadevices created:old:/dev/dsk/c1t0d0s1        -       -       swap    -       no      -/dev/md/dsk/d100        /dev/md/rdsk/d100       /       ufs     1       no      -/dev/dsk/c1t0d0s5       /dev/rdsk/c1t0d0s5       /usr    ufs     1       no      logging/dev/dsk/c1t0d0s4       /dev/rdsk/c1t0d0s4       /var    ufs     1       no      logging#/dev/md/dsk/d206       /dev/md/rdsk/d206       /globaldevices  ufs     2       yes     loggingswap    -       /tmp    tmpfs   -       yes     -/dev/dsk/c1t0d0s6       /dev/rdsk/c1t0d0s6       /global/.devices/node@1 ufs      2       no  globalnew:/dev/md/dsk/d101        -       -       swap    -       no      -/dev/md/dsk/d100        /dev/md/rdsk/d100       /       ufs     1       no      -/dev/md/dsk/d105        /dev/md/rdsk/d105       /usr    ufs     1       no      logging/dev/md/dsk/d104        /dev/md/rdsk/d104       /var    ufs     1       no      logging#/dev/md/dsk/106       /dev/md/rdsk/d106       /globaldevices  ufs     2       yes     loggingswap    -       /tmp    tmpfs   -       yes     -/dev/md/dsk/d106        /dev/md/rdsk/d106       /global/.devices/node@1 ufs     2       noglobal18) Reboot node 0a in order to check new SDS/SVM boot configuration.19) Label the mirror disk c1t1d0 with the VTOC of boot disk c1t0d0:# prtvtoc /dev/dsk/c1t0d0s2 > /var/tmp/VTOC_c1t0d0 # fmthard -s /var/tmp/VTOC_c1t0d0 /dev/rdsk/c1t1d0s220) Put DB replica on slice 7 of disk c1t1d0:# metadb -a -c 3 /dev/dsk/c1t1d0s721) Create metadevice for mirror disk c1t1d0 and attach the new mirror side:# metainit d120 1 1 c1t1d0s0# metattach d100 d120# metainit d121 1 1 c1t1d0s1# metattach d101 d121# metainit d124 1 1 c1t1d0s4# metattach d104 d124# metainit d125 1 1 c1t1d0s5# metattach d105 d125# metainit d126 1 1 c1t1d0s6# metattach d106 d126

    Read the article