Search Results

Search found 112 results on 5 pages for 'fibre'.

Page 2/5 | < Previous Page | 1 2 3 4 5  | Next Page >

  • Virtual fiber channel HBA in Solaris

    - by Phil
    We are trying to set up some virtual Fibre Channel HBA's in Solaris. This seems to be possible with NPIV. Creating NPIV's in a Solaris global zone works fine, but passing that NPIV to a zone didn't work at all. We tried to pass the NPIV as following: # zonecfg -z zone1 'info' zonename: studentz1 [...] device: match: /devices/pci@0,0/pci8086,25f9@6/pci8086,350c@0,3/pci1077,140@4/fp@1,0:devctl allow-partition not specified allow-raw-io not specified Wat we want to do is, set up an environment for SAN exercises. We don't have a physical host per student, so we try to virtualise that in some way (Solaris zones or VMware). It should be possible to display the WWN of the virtual HBA and mount the storage presented by the disk subsystem. Any ideas to pass the NPIV to a solaris zone or to virtualise this with vmware?

    Read the article

  • SAN cache memory upgrade

    - by Scott Lundberg
    We currently have an IBM DS4300 Dual Controller Fibre SAN. It is a good box, but getting pretty old. It came with 256MB of cache per controller. Recently we replaced the batteries in one of the controllers and noticed that the cache is a DDR PC2100 ECC DIMM. Of course, we are thinking about how cheap this RAM is now and is there any good reason we can't upgrade the RAM. IBM used to have a "Turbo" upgrade to this box that doubled the cache and had a bunch of software features for about 10K USD. Since that product has been end-of-lifed, I don't think we can get that upgrade and we don't need the software upgrades (FlashCopy, StorageCopy, etc). Besides the obvious potential warranty issue, what if any issues would we expect to see if attempting to put 2 - 1GB DIMMS in this unit? Any other things I am missing here? EDIT: Memory label: Samsung CN 0433 PC2100U-25331-A1 M381L3223ETM-CB0 256MB DDR PC2100 CL2.5 ECC

    Read the article

  • 2 Server FC SAN Configuration

    - by BSte
    I have 2 identical servers: -48GB Ram -8GigE NIC's -2FC NIC's -2x72GB RAID1 Hard Drives -Server 2008R2 Host I also Have a Fibre Channel SAN: -16x146GB RAID10 Hard Drives -2xDual-port FC Controllers (Controller A and B both have ports 1 and 2) -Server 1 has Fiber to Ports A1 and B1 -Server 2 has Fiber to Ports A2 and B2 -I kept the default config with 1 Virtual Disk and 1 Volume -The default mappings show ports A1,A2,B1,B2 on LUN 0 with read-write My goal is: -2xVM's with IIS and Guest Level Failover -2xVM's with SQL 2008 Enterprise using a Single DB and Guest Level Failover -1xVM that is an application server, preferable with Host Failover. From what I read, this will also need AD for clustering to work. -I need at least 1 VM always running for IIS and the SQLDB. This includes hardware failover and application (ie: reboot a VM for Critical updates) I was told I could install the VM's and run them from the SAN, and this is what I've tried: Installed MPIO and HyperV on Server1 and Server 2 Added the SAN as Disk E: on both servers, made it GPT and formatted NTFS Configured HyperV on both server to store use E:\VD and E:\VHD On server1, I was able to install 3 VM's on the SAN and all worked well. On server2, I would start installing the other 2 VM's, but always at some point the VM's would get a corrupt .VHD message (either server). Everything I found about the message typically related to antivirus, so I removed all antivirus on both Host servers (now only running 2008R2). I reformatted drive E: (SAN), recreated the VHD and VD directories, installed 3 VM's on Server 1, and then had the same issue when installing VM's on Server2. Obviously something is wrong, but I'm not certain what exactly. My questions: 1) Are my goals possible with this hardware setup? -I've read 2008R2 supports FC SAN's, but a lot of articles seem to only give examples with iSCSCI setups 2) What would be the suggested route on setting up the SAN (disks,volumes,LUN's)? I've worked with HyperV on a single machine before and never had issues. Actual experience working on SAN's and clustering is new to me. Any suggestions or recommendations to get me in the right direction would be much appreciated.

    Read the article

  • Diagnosing SAN connectivity issues (RHEL5)

    - by Matthew
    We are currently utilizing GFS2 to share a SAN LUN between 3 servers. However due to a feature problem with vendor software we are using, we currently have the volume unmounted on two of the boxes, and are instead exporting the GFS2 filesystem via NFS from the first one (the software requires some weird locking mechanics that GFS2 doesn't support). As of this morning, NFS was no longer able to read/write to the volume from any of the servers, including the NFS server. I then tried checking the normal mount (the directory that is exported on the NFS server) and I received a weird input/output error just trying to CD into it. When I tried running multipath, I got a DM error, however multipath -l worked just fine. I tried unmounting the GFS2 volume, and the CLI hung. I ran init 0 which killed most services, but then the shutdown appeared to have been hung. I logged in via out of band access (hp ILO) and saw that the shutdown was hung trying to unmount GFS2 volumes. My main priority was getting the box back online so after about 5 minutes of waiting I did a hard reset. I am now trying to figure out what went wrong. What are the correct logs to investigate? I've never run into SAN issues like this before. The SAN is connected via 2 fibre connections. Any help would really be appreciated. Everything appears to be up and functional now.

    Read the article

  • What does this mean: "SATP VMW_SATP_LOCAL does not support device configuration"?

    - by Jason Tan
    Can anyone tell me what this means in ESXi 5.1?: SATP VMW_SATP_LOCAL does not support device configuration I've googled it and I get a lot of results, but as yet all the pages that contain the string are discussing other matters. The storage array is a HDS HUS-VM and the hosts are HP b460c G8 blades with flex fabric and flex fabric VCs which I am in the process of commissioning and would like to get it started on the right foot - i.e. error and warning free! naa.600508b1001c56ee3d70da65f071da23 Device Display Name: HP Serial Attached SCSI Disk (naa.600508b1001c56ee3d70da65f071da23) Storage Array Type: VMW_SATP_LOCAL Storage Array Type Device Config: SATP VMW_SATP_LOCAL does not support device configuration. Path Selection Policy: VMW_PSP_FIXED Path Selection Policy Device Config: {preferred=vmhba0:C0:T0:L1;current=vmhba0:C0:T0:L1} Path Selection Policy Device Custom Config: Working Paths: vmhba0:C0:T0:L1 Is Local SAS Device: true Is Boot USB Device: false This is the same LUN: ~ # esxcli storage core device list -d naa.60060e80132757005020275700000016 naa.60060e80132757005020275700000016 Display Name: HITACHI Fibre Channel Disk (naa.60060e80132757005020275700000016) Has Settable Display Name: true Size: 204800 Device Type: Direct-Access Multipath Plugin: NMP Devfs Path: /vmfs/devices/disks/naa.60060e80132757005020275700000016 Vendor: HITACHI Model: OPEN-V Revision: 5001 SCSI Level: 2 Is Pseudo: false Status: degraded Is RDM Capable: true Is Local: false Is Removable: false Is SSD: false Is Offline: false Is Perennially Reserved: false Queue Full Sample Size: 0 Queue Full Threshold: 0 Thin Provisioning Status: unknown Attached Filters: VAAI_FILTER VAAI Status: supported Other UIDs: vml.020001000060060e801327570050202757000000164f50454e2d56 Is Local SAS Device: false Is Boot USB Device: false ~ #

    Read the article

  • Linux Fiber Channel Host Setup Basic

    - by Jim
    I've been googling for about 4 hours now with no luck. I am trying to setup a Linux server running Oracle Server 6.3 as a Fiber Channel host. And then connect it to a Dell Compellent Fibre Channel Host contain a 500GB Volume. The Oracle server itself contains two Brocade 815 FC HBAs. I've discovered their WWN(I think) via cat /sys/class/fc_host/host1/port_name 0x100000051efc3d85 cat /sys/class/fc_host/host2/port_name 0x100000051efc3d9f The next part is where I am at a loss. I've used iSCSI before...is FC the same deal where you have an initiator and a target? If so where do I specific that in linux? I'm also new to Fiber Channel as a protocol, so i am unsure what is needed to make a transaction? WWN and port ID? Similar to IP:Port combination in the Ethernet world. I've read alot regarding using systool, multipath, fc_transport commands, however none of these is recognized as a valid command from Oracle Server 6.3 Appreciate the guidance and assistance. I installed sccsi-target-utils and can now run rescan-scsi-bus and sg_map -x. rescan-scsi-bus.sh -l -w -r Host adapter 0 (megaraid_sas) found. Host adapter 1 ((null)) found. Host adapter 2 ((null)) found. Host adapter 3 (ata_piix) found. Host adapter 4 (ata_piix) found. Scanning SCSI subsystem for new devices and remove devices that have disappeared Scanning host 0 for SCSI target IDs 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15, LUNs 0 1 2 3 4 5 6 7 Scanning for device 0 2 0 0 .... OLD: Host: scsi0 Channel: 02 Id: 00 Lun: 00 Vendor: DELL Model: PERC H700 Rev: 2.30 Type: Direct-Access ANSI SCSI revision: 05 Scanning for device 0 2 1 0 ... OLD: Host: scsi0 Channel: 02 Id: 01 Lun: 00 Vendor: DELL Model: PERC H700 Rev: 2.30 Type: Direct-Access ANSI SCSI revision: 05 Scanning host 1 for all SCSI target IDs, LUNs 0 1 2 3 4 5 6 7 Scanning for device 1 0 3 1 ... OLD: Host: scsi1 Channel: 00 Id: 03 Lun: 01 Vendor: COMPELNT Model: Compellent Vol Rev: 0505 Type: Direct-Access ANSI SCSI revision: 05 Scanning host 2 for all SCSI target IDs, LUNs 0 1 2 3 4 5 6 7 Scanning host 3 for all SCSI target IDs, LUNs 0 1 2 3 4 5 6 7 Scanning for device 3 0 0 0 ... REM: Host: scsi3 Channel: 00 Id: 00 Lun: 00 DEL: Vendor: TEAC Model: DVD-ROM DV-28SW Rev: R.2A Type: CD-ROM ANSI SCSI revision: 05 Scanning host 4 channels 0 for SCSI target IDs 0, LUNs 0 1 2 3 4 5 6 7 0 new device(s) found. 1 device(s) removed. and sg_map -x /dev/sg0 0 0 32 0 13 /dev/sg1 0 2 0 0 0 /dev/sda /dev/sg2 0 2 1 0 0 /dev/sdb /dev/sg4 1 0 3 1 0 /dev/sdc I'm not sure what this all means...

    Read the article

  • Un FAI anglais va équiper une ville entière en fibre à 1 Gbps, aimeriez-vous utiliser un tel débit chez vous ?

    Un FAI britannique va équiper toute une ville de fibre à 1 Gb pour un test grandeur nature, aimeriez-vous utiliser un tel débit ? Alors que la Commission Européenne vient de faire des recommandations précises pour aider les pays européens à avancer vers de meilleurs installations numériques, l'Angleterre semble avoir bien reçu le message concernant le fait de booster le réseau Internet. Le Royaume de sa Majesté a en effet décidé de devenir le pays de l'Union doté des meilleures connexions en 2015 Le secrétaire à la Culture, Jer...

    Read the article

  • RHEL - blocked FC remote port time out: saving binding

    - by Dev G
    My Server went into a faulty state since the database could not write on the partition. I found out that the partition went into Read Only mode. Finally to fix it, I had to do a hard reboot. Linux 2.6.18-164.el5PAE #1 SMP Tue Aug 18 15:59:11 EDT 2009 i686 i686 i386 GNU/Linux /var/log/messages Oct 31 00:56:45 ota3g1 Had[17275]: VCS ERROR V-16-1-10214 Concurrency Violation:CurrentCount increased above 1 for failover group sg_network Oct 31 00:57:05 ota3g1 Had[17275]: VCS CRITICAL V-16-1-50086 CPU usage on ota3g1.mtsallstream.com is 100% Oct 31 01:01:47 ota3g1 Had[17275]: VCS ERROR V-16-1-10214 Concurrency Violation:CurrentCount increased above 1 for failover group sg_network Oct 31 01:06:50 ota3g1 Had[17275]: VCS ERROR V-16-1-10214 Concurrency Violation:CurrentCount increased above 1 for failover group sg_network Oct 31 01:11:52 ota3g1 Had[17275]: VCS ERROR V-16-1-10214 Concurrency Violation:CurrentCount increased above 1 for failover group sg_network Oct 31 01:12:10 ota3g1 kernel: lpfc 0000:29:00.1: 1:1305 Link Down Event x2 received Data: x2 x20 x80000 x0 x0 Oct 31 01:12:10 ota3g1 kernel: lpfc 0000:29:00.1: 1:1303 Link Up Event x3 received Data: x3 x1 x10 x1 x0 x0 0 Oct 31 01:12:12 ota3g1 kernel: lpfc 0000:29:00.1: 1:1305 Link Down Event x4 received Data: x4 x20 x80000 x0 x0 Oct 31 01:12:40 ota3g1 kernel: rport-8:0-0: blocked FC remote port time out: saving binding Oct 31 01:12:40 ota3g1 kernel: lpfc 0000:29:00.1: 1:(0):0203 Devloss timeout on WWPN 20:25:00:a0:b8:74:f5:65 NPort x0000e4 Data: x0 x7 x0 Oct 31 01:12:40 ota3g1 kernel: sd 8:0:0:4: SCSI error: return code = 0x00010000 Oct 31 01:12:40 ota3g1 kernel: end_request: I/O error, dev sdi, sector 38617577 Oct 31 01:12:40 ota3g1 kernel: sd 8:0:0:4: SCSI error: return code = 0x00010000 Oct 31 01:12:40 ota3g1 kernel: end_request: I/O error, dev sdi, sector 283532153 Oct 31 01:12:40 ota3g1 kernel: sd 8:0:0:4: SCSI error: return code = 0x00010000 Oct 31 01:12:40 ota3g1 kernel: end_request: I/O error, dev sdi, sector 90825 Oct 31 01:12:40 ota3g1 kernel: Aborting journal on device dm-16. Oct 31 01:12:40 ota3g1 kernel: sd 8:0:0:4: SCSI error: return code = 0x00010000 Oct 31 01:12:40 ota3g1 kernel: end_request: I/O error, dev sdi, sector 868841 Oct 31 01:12:40 ota3g1 kernel: sd 8:0:0:4: SCSI error: return code = 0x00010000 Oct 31 01:12:40 ota3g1 kernel: Aborting journal on device dm-10. Oct 31 01:12:40 ota3g1 kernel: end_request: I/O error, dev sdi, sector 37759889 Oct 31 01:12:40 ota3g1 kernel: sd 8:0:0:4: SCSI error: return code = 0x00010000 Oct 31 01:12:40 ota3g1 kernel: end_request: I/O error, dev sdi, sector 283349449 Oct 31 01:12:40 ota3g1 kernel: printk: 6 messages suppressed. Oct 31 01:12:40 ota3g1 kernel: Aborting journal on device dm-12. Oct 31 01:12:40 ota3g1 kernel: EXT3-fs error (device dm-12) in ext3_reserve_inode_write: Journal has aborted Oct 31 01:12:40 ota3g1 kernel: Buffer I/O error on device dm-16, logical block 1545 Oct 31 01:12:40 ota3g1 kernel: lost page write due to I/O error on dm-16 Oct 31 01:12:40 ota3g1 kernel: sd 8:0:0:4: SCSI error: return code = 0x00010000 Oct 31 01:12:40 ota3g1 kernel: end_request: I/O error, dev sdi, sector 12745 Oct 31 01:12:40 ota3g1 kernel: Buffer I/O error on device dm-10, logical block 1545 Oct 31 01:12:40 ota3g1 kernel: EXT3-fs error (device dm-16) in ext3_reserve_inode_write: Journal has aborted Oct 31 01:12:40 ota3g1 kernel: lost page write due to I/O error on dm-10 Oct 31 01:12:40 ota3g1 kernel: sd 8:0:0:4: SCSI error: return code = 0x00010000 Oct 31 01:12:40 ota3g1 kernel: end_request: I/O error, dev sdi, sector 37749121 Oct 31 01:12:40 ota3g1 kernel: Buffer I/O error on device dm-12, logical block 0 Oct 31 01:12:40 ota3g1 kernel: lost page write due to I/O error on dm-12 Oct 31 01:12:40 ota3g1 kernel: sd 8:0:0:4: SCSI error: return code = 0x00010000 Oct 31 01:12:40 ota3g1 kernel: EXT3-fs error (device dm-12) in ext3_dirty_inode: Journal has aborted Oct 31 01:12:40 ota3g1 kernel: end_request: I/O error, dev sdi, sector 37757897 Oct 31 01:12:40 ota3g1 kernel: Buffer I/O error on device dm-12, logical block 1097 Oct 31 01:12:40 ota3g1 kernel: lost page write due to I/O error on dm-12 Oct 31 01:12:40 ota3g1 kernel: sd 8:0:0:4: SCSI error: return code = 0x00010000 Oct 31 01:12:40 ota3g1 kernel: end_request: I/O error, dev sdi, sector 283337089 Oct 31 01:12:40 ota3g1 kernel: Buffer I/O error on device dm-16, logical block 0 Oct 31 01:12:40 ota3g1 kernel: lost page write due to I/O error on dm-16 Oct 31 01:12:40 ota3g1 kernel: sd 8:0:0:4: SCSI error: return code = 0x00010000 Oct 31 01:12:40 ota3g1 kernel: EXT3-fs error (device dm-16) in ext3_dirty_inode: Journal has aborted Oct 31 01:12:40 ota3g1 kernel: end_request: I/O error, dev sdi, sector 37749121 Oct 31 01:12:40 ota3g1 kernel: Buffer I/O error on device dm-12, logical block 0 Oct 31 01:12:41 ota3g1 kernel: lost page write due to I/O error on dm-12 Oct 31 01:12:41 ota3g1 kernel: sd 8:0:0:4: SCSI error: return code = 0x00010000 Oct 31 01:12:41 ota3g1 kernel: end_request: I/O error, dev sdi, sector 283337089 Oct 31 01:12:41 ota3g1 kernel: Buffer I/O error on device dm-16, logical block 0 Oct 31 01:12:41 ota3g1 kernel: lost page write due to I/O error on dm-16 Oct 31 01:12:41 ota3g1 kernel: sd 8:0:0:4: SCSI error: return code = 0x00010000 df -h Filesystem Size Used Avail Use% Mounted on /dev/mapper/cciss-root 4.9G 730M 3.9G 16% / /dev/mapper/cciss-home 9.7G 1.2G 8.1G 13% /home /dev/mapper/cciss-var 9.7G 494M 8.8G 6% /var /dev/mapper/cciss-usr 15G 2.6G 12G 19% /usr /dev/mapper/cciss-tmp 3.9G 153M 3.6G 5% /tmp /dev/sda1 996M 43M 902M 5% /boot tmpfs 5.9G 0 5.9G 0% /dev/shm /dev/mapper/cciss-product 25G 16G 7.4G 68% /product /dev/mapper/cciss-opt 20G 4.5G 14G 25% /opt /dev/mapper/dg_db1-vol_db1_system 18G 2.2G 15G 14% /database/OTADB/sys /dev/mapper/dg_db1-vol_db1_undo 18G 5.8G 12G 35% /database/OTADB/undo /dev/mapper/dg_db1-vol_db1_redo 8.9G 4.3G 4.2G 51% /database/OTADB/redo /dev/mapper/dg_db1-vol_db1_sgbd 8.9G 654M 7.8G 8% /database/OTADB/admin /dev/mapper/dg_db1-vol_db1_arch 98G 24G 69G 26% /database/OTADB/arch /dev/mapper/dg_db1-vol_db1_indexes 240G 14G 214G 6% /database/OTADB/index /dev/mapper/dg_db1-vol_db1_data 275G 47G 215G 18% /database/OTADB/data /dev/mapper/dg_dbrman-vol_db_rman 8.9G 351M 8.1G 5% /database/RMAN /dev/mapper/dg_app1-vol_app1 151G 113G 31G 79% /files/ota /etc/fstab /dev/cciss/root / ext3 defaults 1 1 /dev/cciss/home /home ext3 defaults 1 2 /dev/cciss/var /var ext3 defaults 1 2 /dev/cciss/usr /usr ext3 defaults 1 2 /dev/cciss/tmp /tmp ext3 defaults 1 2 LABEL=/boot /boot ext3 defaults 1 2 tmpfs /dev/shm tmpfs defaults 0 0 devpts /dev/pts devpts gid=5,mode=620 0 0 sysfs /sys sysfs defaults 0 0 proc /proc proc defaults 0 0 /dev/cciss/swap swap swap defaults 0 0 /dev/cciss/product /product ext3 defaults 1 2 /dev/cciss/opt /opt ext3 defaults 1 2 /dev/dg_db1/vol_db1_system /database/OTADB/sys ext3 defaults 1 2 /dev/dg_db1/vol_db1_undo /database/OTADB/undo ext3 defaults 1 2 /dev/dg_db1/vol_db1_redo /database/OTADB/redo ext3 defaults 1 2 /dev/dg_db1/vol_db1_sgbd /database/OTADB/admin ext3 defaults 1 2 /dev/dg_db1/vol_db1_arch /database/OTADB/arch ext3 defaults 1 2 /dev/dg_db1/vol_db1_indexes /database/OTADB/index ext3 defaults 1 2 /dev/dg_db1/vol_db1_data /database/OTADB/data ext3 defaults 1 2 /dev/dg_dbrman/vol_db_rman /database/RMAN ext3 defaults 1 2 /dev/dg_app1/vol_app1 /files/ota ext3 defaults 1 2 Thanks for all the help.

    Read the article

  • Understanding Linux SCSI queue depths

    - by Troels Arvin
    I'm experimenting with the effects of different SCSI queue depth values on a Dell server running CentOS Linux 5.4 (x86_64). The server has two QLogic QLE2560 FC HBAs connected via multipathing to a storage system. The storage system has allocated two LUNs to the server, each connected through four paths in an active-active-active-active round-robin configuration. All in all, the two LUNs exist as eight /dev/sdX devices, represented by two devices in /dev/mpath. I currently adjust the queue depth values in /etc/modprobe.conf and check the result (after rebooting) by looking in the seventh column of /proc/scsi/sg/devices. Two questions related to that: Is there a way to adjust queue depths without rebooting or unloading the qla2xxx kernel module? E.g., can I echo a new queue depth value into some /proc or /sys-like file to update the queue depth? If I set the queue depth to 128, is that 128 in total for all devices handled by the qla2xxx module?, or 128 for each HBA? (256 in total), or 128 for each of the eight /dev/sdX devices (1024 in toal)?, or 128 for each of the two /dev/mpath/... devices (256 in total)? This is important for me to know so that my server doesn't flood the storage system, affecting other servers connected to it.

    Read the article

  • Debian and Multipath IO problem

    - by tearman
    Basically the situation is, I have a box running Debian, the box internally has an Intel SCSI RAID controller which is controlling 2 hard drives in RAID1 mode which is where the OS is installed. Further, I have a QLogic fiber channel adapter that connects the unit to a Fiber Channel SAN. My process of installation is I'll install Debian to the local drives, and leave the QLogic firmware out of it for the time being. Then once I get the unit online, I'll install the firmware drivers. This flops my internal drives from /dev/sda to /dev/sdc, which is a bit annoying, but recoverable. Probably should address these by UUID anyways. Once I get back online, I have to install multipath-tools (the framework is a multipath framework). However, once I reboot the machine again, it fails on boot after discovering multipath targets, saying my local drives are busy and cannot be mounted to /root. Any help in what may be the problem here? Or at least how to disable multipath until after the unit boots and then ignores the internal drives?

    Read the article

  • Can I have different ESX hosts accessing the same LUN over different protocols?

    - by Kevin Kuphal
    I currently have a cluster of two ESX 3.5U2 servers connected directly via FiberChannel to a NetApp 3020 cluster. These hosts mount four VMFS LUNs for virtual machine storage. Currently these LUNs are only made available via our FiberChannel initator in the Netapp configuration If I were to add an ESXi host to the cluster for internal IT use can I: Make the same VMFS LUNs available via the iSCSI initiator on the Netapp Connect this ESXi host to those LUNs via iSCSI Do all of this while the existing two ESX hosts are connected to those LUNs via FiberChannel Does anyone have experience with this type of mixed protocol environment, specifically with Netapp?

    Read the article

  • How to block some disks from probes on Linux boot?

    - by Igor Velkov
    My linux host connected to SAN with FC interface. It connect with one path, and see some luns, that can't access, because they need anohter path, not available to host. On boot linux probe all lun he can see, get read error on unaccessible luns, and hangs there for a long-long time. Is there a way to disable any access to some luns at boot time, and later? I found a filters for device ignoration for LVM and MULTIPATH, but it not help during boot process. Generally, lvm still affected too despite of filter, and gives me a IO error on every operation like lvdisplay and vgdisplay, but this is another question.

    Read the article

  • Fiber Channel Loop vs Point to Point

    - by RandomInsano
    So, I'm playing with a couple of QLogic QLA2340s connected directly together. I've got options here to either have them act as a loop, or in point to point mode. What's the difference if I'm only going to have two machines connected together? Is point-to-point more efficient? The firmware has an option to prefer loop, then fall back to p2p. Anyone have any idea if there are performance benefits or drawbacks? It's pretty hard to find that information.

    Read the article

  • SAN newbie: What kind of fiber cables do I need to connect to the front end ports on my EMC CX300

    - by red888
    I have an old CX300 I'm messing with and I cant determine what kind of HBA\fiber cables I need to connect a server to the front end ports on the DPE2. The hardware reference doesn't give me any details and being new to FC-SAN all of the options are pretty overwhelming. I don't know if the ports are SC or LC or if it requires singlemode or multimode. Googling hasn't turned up anything for me either. All I know is that it supports 2GB Fiber. Here is a pic of one the modules. You can clearly see the front-end ports (FE)

    Read the article

  • Merit and demerits for various Linux fiberchannel multipath options

    - by wzzrd
    On our Linux servers, we currently use HPs qla2xxx drivers, because it has multipathing (active/passive) built in. The are, however, various other options, like Red Hats device-mapper-multipath with the stock qla2xxx drivers (multibus and failover) and things like SecurePath and PowerPath (both of which can do trunking, iirc). Can someone tell me what the merits and demerits of the various options are (if I can ask such a question), besides the obvious fact that the {Secure,Power}Path options cost vast amounts of money? I'm mainly interested in the freely available options, like HPs qla2xxx vs. Red Hats multipathd and possible other open source solutions, but I would like to hear good reasons to go for the commercial solutions too. UPDATE: I'll be benchmarking various options the coming few days (the average of 10 runs of iozone for each option (options being native qla2xxx failver, native qla2xxx multibus, HP qla2xxx failover)). I'll post a summary of results here for those interested.

    Read the article

  • Cisco FC SAN switch decision

    - by Chopper3
    I've got to buy a bunch of FC SAN switches in the next week or so, I have to, and want to, buy Cisco MDSs. Servers are HP BL490c G6's in C7000 chassis with Virtual-Connect Flex-10 ethernet interconnects and VC FC interconnects (Emulex HBAs btw), all running ESX 3.5U4 (for now). I think I've only really got two choices; MDS 9509's with dual-supervisors with a single 48-port 4Gb FC card MDS 9222i's with single supervisor and the built-in 18-FC-port/4-GigE-FCIP-port option Both have the same functionality (I think, buying the enterprise licence btw), both have plenty enough performance and adequate ports for now and the next three years. The 9222i's are about 55% the price of the 9509's - logic says get the 'i's but will I really miss the dual-supervisors? I've got lots of 9509's with dual-supervisors that I'm very happy with but I'm not sure I've every benefitted from the dual-sups in the past and they are nearly twice the price - but if I don't buy them and miss them I can't retrofit them later. What are your thoughts?

    Read the article

  • Fiber in Cable Management Arm

    - by mrtroy
    I'm aware of the existing debate on cable management arms. For those people who DO use cable management arms, do you put Fiber into the arms? It looks like I'm fine on minimum bend radii, but am looking for additional opinions before I do anything. -Troy

    Read the article

  • Are FC and SAS DAS devices standard enough?

    - by user222182
    Before I ask my questions, here is some background info that may or may not be useful: For the first time I find myself needing a DAS solution. My priority is data through-put in a single direction. I can write large blocks, and I don't need to read at the same time. The server (the data producing device) is not really a typical server, its a very powerful single board computer. As such I have limited options when it comes to the add-in cards I can install since it must use the fairly uncommon interface, XMC. Currently I believe I am limited PCIex8 gen 1 which means that the likely bottle neck for me will be this 16gbps connection. XMC Boards I have found so far offer the following connections: a) Dual 10GBE ethernet controller, total throughput 20gbps b) Dual Quad SAS 2.0 Connectors (SFF-8XXX) HBA (no raid), total throughput 48 gbps c) Dual FC 8gb HBA (no raid), total throughput 16gbps My questions for you guys are: 1) Are SAS and/or FC, and by extension their HBAs, standard enough that I could purchase a Dell or Aberdeen storage server with a raid controller that has external SAS or FC ports and expect that I can connect it to my SAS or FC HBA, be presented with a single volume (if I so configured the storage server), all without having to check for HBA compatibility? 2) On a device like a Dell PowerVault (either DAS or NAS) is there an OS on it to concern myself with, or is it meant to be remotely managed? Is there a local interface in case I cant remotely manage it (i.e. if my single board computer uses an OS not supported by Dell OpenManage). Would this be true of nearly any device which calls itself a DAS? 3) If I purchase some sort of Supermicro storage chassis, installed a raid controller with external connections, is there a nice lightweight OS I can run just for management of the controller? Would I even need an OS since the raid card would be configured pre-boot anyway? 4) It is much easier to buy XMC based 10gigabit ethernet cards (generally dual port). In what ways would I be getting into trouble by using iSCSI as a DAS are direct cabling with SFP+ cables? Thanks in advance

    Read the article

  • Which events specifically cause Windows 2008 to mark a SAN volume offline?

    - by Jeremy
    I am searching for specific criteria/events that will cause Windows 2008 to mark a SAN volume as offline in disk management, even though it is connected to that SAN volume via FC or iSCSI. Microsoft states that "A dynamic disk may become Offline if it is corrupted or intermittently unavailable. A dynamic disk may also become Offline if you attempt to import a foreign (dynamic) disk and the import fails. An error icon appears on the Offline disk. Only dynamic disks display the Missing or Offline status." I am specifically wondering if, on the SAN, changing the path to the disk (such as the disk being presented to the host via a different iSCSI target IQN or a different LUN #) would cause a volume to be offlined in disk management. Thanks! Edit: I have already found two reasons why a disk might be set offline, disk signature collisions and the SAN disk policy. Bounty would be awarded to someone who can find further documented reasons related to changes in the volume's path. Disk signature collisions: http://blogs.technet.com/b/markrussinovich/archive/2011/11/08/3463572.aspx SAN disk policy: http://jeffwouters.nl/index.php/2011/06/disk-offline-with-error-the-disk-is-offline-because-of-a-policy-set-by-an-administrator/

    Read the article

  • How do I resolve an "Invalid Transaction" error saving a zone config in Brocade Web Tools?

    - by Frank Szczerba
    When trying to save zoning changes in the Zone Administration tool in Brocade Web Tools, I get the status "Failed to commit changes to fabric" and the messages window shows: --- start of commit (Enable Config) at: Fri Jul 23 2010 19:43:40 GMT+00:00 Invalid Transaction --- end of commit at: Fri Jul 23 2010 19:43:47 GMT+00:00 I've tried refreshing the config and just re-saving what is already on the switch, but can't get this message to go away.

    Read the article

  • Problem connecting a 3Com 2952-Plus switch to a Cisco 3750 switch

    - by Noel
    Connected a 3Com 2952-SFP Plus switch to a Cisco 3750 switch via fibre. There is a light on the 3Com end, but nothing at the Cisco end, and no traffic will flow. Have swapped SFP's, have swapped fibre cables, have used a different port on the Cisco, have even swapped the 3Com switch, but still no joy. When I connect a 3Com 2948 switch over fibre that works OK. Any ideas?

    Read the article

  • Connecting XRAID to Sunfire via LSI FC card - Drives not showing up

    - by Matthew Watson
    Hi, I've got a Sunfire T1000 machine ( Solaris 10 10/09 s10s_u8wos_08a SPARC ) with a LSI7404EP-LC fibre channel card in it. This is plugged into an XRAID. The system seems to have picked up the card > /usr/platform/`uname -i `/sbin/prtdiag IO Location Type Slot Path Name Model ----------- ----- ---- --------------------------------------------- ------------------------- --------- MB/PCIE0 PCIE 0 /pci@780/fibre-channel fibre-channel MB/PCIE0 PCIE 0 /pci@780/fibre-channel fibre-channel MB/NET0 PCIE MB /pci@7c0/pci@0/network@4 network-pci14e4,1668 MB/NET1 PCIE MB /pci@7c0/pci@0/network@4,1 network-pci14e4,1668 MB/NET2 PCIX MB /pci@7c0/pci@0/pci@8/network@1 network-pci108e,1648 MB/NET3 PCIX MB /pci@7c0/pci@0/pci@8/network@1,1 network-pci108e,1648 MB/PCIX PCIX MB /pci@7c0/pci@0/pci@8/scsi@2 scsi-pci1000,50 LSI,1064 However it doesn't seem to be able to see the xraid attached to it, lsiutil only reports the onboard SAS controller. > /usr/local/bin/lsiutil ~ LSI Logic MPT Configuration Utility, Version 1.62, January 14, 2009 1 MPT Port found Port Name Chip Vendor/Type/Rev MPT Rev Firmware Rev IOC 1. mpt0 LSI Logic SAS1064 A3 105 010a0000 0 Select a device: [1-1 or 0 to quit] I've tried adding the configuration to /kernal/drv/sd.conf and /kernal/drv/ssd.conf as per this thread, however format still cannot see any drives on the xraid. I'm not sure where to go next. Any suggestions? From what I've read..this should pretty much just eb plug it in and they show up in format..

    Read the article

  • How to tell if linux disk IO is causing excessive (> 1 second) application stalls

    - by noahz
    I have a Java application performing a large volume (hundreds of MB) of continuous output (streaming plain text) to about a dozen files a ext3 SAN filesystem. Occasionally, this application pauses for several seconds at a time. I suspect that something related to ext3 vsfs (Veritas Filesystem) functionality (and/or how it interacts with the OS) is the culprit. What steps can I take to confirm or refute this theory? I am aware of iostat and /proc/diskstats as starting points. Revised title to de-emphasize journaling and emphasize "stalls" I have done some googling and found at least one article that seems to describe behavior like I am observing: Solving the ext3 latency problem Additional Information Red Hat Enterprise Linux Server release 5.3 (Tikanga) Kernel: 2.6.18-194.32.1.el5 Primary application disk is fiber-channel SAN: lspci | grep -i fibre 14:00.0 Fibre Channel: Emulex Corporation Saturn-X: LightPulse Fibre Channel Host Adapter (rev 03) Mount info: type vxfs (rw,tmplog,largefiles,mincache=tmpcache,ioerror=mwdisable) 0 0 cat /sys/block/VxVM123456/queue/scheduler noop anticipatory [deadline] cfq

    Read the article

< Previous Page | 1 2 3 4 5  | Next Page >