Search Results

Search found 217 results on 9 pages for 'poweredge'.

Page 4/9 | < Previous Page | 1 2 3 4 5 6 7 8 9  | Next Page >

  • Dell OpenManage On Ubuntu Server 12.04 Cannot Log In

    - by Austin
    I have a Dell Poweredge 2950 with 2X130GB and 2X2TB drives. I need to set them up in a RAID 1 array so that the 130GB Drives are mirrored and host the OS, while the 2TB drives are mirrored and are the content drives. So I go from 4 disks, down to two, one 130GB and one 2TB. I can do that in the BIOS RAID utility no problem. But I need to be able to manage the RAID arrays and be able to expand them WITHOUT shutting down the server. Now, to my understanding, openmanage will allow me to do that AND it runs on ubuntu. So I go and set it up and try to log into the web interface at and it will not let me log in. I have followed dell's guide to set up openmanage, even added the usernames to the files and permissions and such, however, cannot get it to let me log in or anything. I have reinstalled Openmanage several times, even reinstalled the OS three times, and nothing works. Google does not help either. It simply says login failed after hitting submit. Please Help

    Read the article

  • Why is domU faster than dom0 on IO?

    - by Paco
    I have installed debian 7 on a physical machine. This is the configuration of the machine: 3 hard drives using RAID 5 Strip element size: 1M Read policy: Adaptive read ahead Write policy: Write Through /boot 200 MB ext2 / 15 GB ext3 SWAP 10GB LVM rest (~500GB) emphasized text I installed postgresql, created a big database (over 1GB). I have an SQL request that takes a lot of time to run (a SELECT statement, so it only reads data from the database). This request takes approximately 5.5 seconds to run. Then, I installed XEN, created a domU, with another debian distro. On this OS, I also installed postgresql, with the same database. The same SQL request takes only 2.5 seconds to run. I checked the kernel on both dom0 and domU. uname-a returns "Linux debian 3.2.0-4-amd64 #1 SMP Debian 3.2.41-2+deb7u2 x86_64 GNU/Linux" on both systems. I checked the kernel parameters, which are approximately the same. For those that are relevant, I changed their values to make them match on both systems using sysctl. I saw no changes (the requests still take the same amount of time). After this, I checked the file systems. I used ext3 on domU. Still no changes. I installed hdparm, and ran hdparm -Tt on both systems, on all my partitions on both systems, and I get similar results. Now, I am stuck, I don't know what is different, and what could be the cause of such a big difference. Additional Info: Debian runs on a Dell server PowerEdge 2950 postgresql: 9.1.9 (both dom0 and domU) xen-linux-system: 3.2.0 xen-hypervisor: 4.1 Thanks EDIT: As Krzysztof Ksiezyk suggested, it might be due to some file caching system. I ran the dd command to test both the read and write speed. Here is domU: root@test1:~# dd if=/dev/zero of=/root/dd count=5MB bs=1MB ^C2020+0 records in 2020+0 records out 2020000000 bytes (2.0 GB) copied, 18.8289 s, 107 MB/s root@test1:~# dd if=/root/dd of=/dev/null count=5MB bs=1MB 2020+0 records in 2020+0 records out 2020000000 bytes (2.0 GB) copied, 15.0549 s, 134 MB/s And here is dom0: root@debian:~# dd if=/dev/zero of=/root/dd count=5MB bs=1MB ^C1693+0 records in 1693+0 records out 1693000000 bytes (1.7 GB) copied, 8.87281 s, 191 MB/s root@debian:~# dd if=/root/dd of=/dev/null count=5MB bs=1MB 1693+0 records in 1693+0 records out 1693000000 bytes (1.7 GB) copied, 0.501509 s, 3.4 GB/s What can be the cause of this caching system? And how can we "fix" it? Can we apply it to dom0? EDIT 2: I switched my virtual disk type. To do so I followed this article. I did a dd if=/dev/vg0/test1-disk of=/mnt/test1-disk.img bs=16M Then in /etc/xen/test1.cfg, I changed the disk parameter to use file: instead of phy: it should have removed the file caching, but I still get the same numbers (domU being much faster for Postgres)

    Read the article

  • "power limit notification" clobbering on 12G Dell servers with RHEL6

    - by Andrew B
    Server: Poweredge r620 OS: RHEL 6.4 Kernel: 2.6.32-358.18.1.el6.x86_64 I'm experiencing application alarms in my production environment. Critical CPU hungry processes are being starved of resources and causing a processing backlog. The problem is happening on all the 12th Generation Dell servers (r620s) in a recently deployed cluster. As near as I can tell, instances of this happening are matching up to peak CPU utilization, accompanied by massive amounts of "power limit notification" spam in dmesg. An excerpt of one of these events: Nov 7 10:15:15 someserver [.crit] CPU12: Core power limit notification (total events = 14) Nov 7 10:15:15 someserver [.crit] CPU0: Core power limit notification (total events = 14) Nov 7 10:15:15 someserver [.crit] CPU6: Core power limit notification (total events = 14) Nov 7 10:15:15 someserver [.crit] CPU14: Core power limit notification (total events = 14) Nov 7 10:15:15 someserver [.crit] CPU18: Core power limit notification (total events = 14) Nov 7 10:15:15 someserver [.crit] CPU2: Core power limit notification (total events = 14) Nov 7 10:15:15 someserver [.crit] CPU4: Core power limit notification (total events = 14) Nov 7 10:15:15 someserver [.crit] CPU16: Core power limit notification (total events = 14) Nov 7 10:15:15 someserver [.crit] CPU0: Package power limit notification (total events = 11) Nov 7 10:15:15 someserver [.crit] CPU6: Package power limit notification (total events = 13) Nov 7 10:15:15 someserver [.crit] CPU14: Package power limit notification (total events = 14) Nov 7 10:15:15 someserver [.crit] CPU18: Package power limit notification (total events = 14) Nov 7 10:15:15 someserver [.crit] CPU20: Core power limit notification (total events = 14) Nov 7 10:15:15 someserver [.crit] CPU8: Core power limit notification (total events = 14) Nov 7 10:15:15 someserver [.crit] CPU2: Package power limit notification (total events = 12) Nov 7 10:15:15 someserver [.crit] CPU10: Core power limit notification (total events = 14) Nov 7 10:15:15 someserver [.crit] CPU22: Core power limit notification (total events = 14) Nov 7 10:15:15 someserver [.crit] CPU4: Package power limit notification (total events = 14) Nov 7 10:15:15 someserver [.crit] CPU16: Package power limit notification (total events = 13) Nov 7 10:15:15 someserver [.crit] CPU20: Package power limit notification (total events = 14) Nov 7 10:15:15 someserver [.crit] CPU8: Package power limit notification (total events = 14) Nov 7 10:15:15 someserver [.crit] CPU10: Package power limit notification (total events = 14) Nov 7 10:15:15 someserver [.crit] CPU22: Package power limit notification (total events = 14) Nov 7 10:15:15 someserver [.crit] CPU15: Core power limit notification (total events = 369) Nov 7 10:15:15 someserver [.crit] CPU3: Core power limit notification (total events = 369) Nov 7 10:15:15 someserver [.crit] CPU1: Core power limit notification (total events = 369) Nov 7 10:15:15 someserver [.crit] CPU5: Core power limit notification (total events = 369) Nov 7 10:15:15 someserver [.crit] CPU17: Core power limit notification (total events = 369) Nov 7 10:15:15 someserver [.crit] CPU13: Core power limit notification (total events = 369) Nov 7 10:15:15 someserver [.crit] CPU15: Package power limit notification (total events = 375) Nov 7 10:15:15 someserver [.crit] CPU3: Package power limit notification (total events = 374) Nov 7 10:15:15 someserver [.crit] CPU1: Package power limit notification (total events = 376) Nov 7 10:15:15 someserver [.crit] CPU5: Package power limit notification (total events = 376) Nov 7 10:15:15 someserver [.crit] CPU7: Core power limit notification (total events = 369) Nov 7 10:15:15 someserver [.crit] CPU19: Core power limit notification (total events = 369) Nov 7 10:15:15 someserver [.crit] CPU17: Package power limit notification (total events = 377) Nov 7 10:15:15 someserver [.crit] CPU9: Core power limit notification (total events = 369) Nov 7 10:15:15 someserver [.crit] CPU21: Core power limit notification (total events = 369) Nov 7 10:15:15 someserver [.crit] CPU23: Core power limit notification (total events = 369) Nov 7 10:15:15 someserver [.crit] CPU11: Core power limit notification (total events = 369) Nov 7 10:15:15 someserver [.crit] CPU13: Package power limit notification (total events = 376) Nov 7 10:15:15 someserver [.crit] CPU7: Package power limit notification (total events = 375) Nov 7 10:15:15 someserver [.crit] CPU19: Package power limit notification (total events = 375) Nov 7 10:15:15 someserver [.crit] CPU9: Package power limit notification (total events = 374) Nov 7 10:15:15 someserver [.crit] CPU21: Package power limit notification (total events = 375) Nov 7 10:15:15 someserver [.crit] CPU23: Package power limit notification (total events = 374) A little Google Fu reveals that this is typically associated with the CPU running hot, or voltage regulation kicking in. I don't think that's what is happening though. Temperature sensors for all servers in the cluster are running fine, Power Cap Policy is disabled in the iDRAC, and my System Profile is set to "Performance" on all of these servers: # omreport chassis biossetup | grep -A10 'System Profile' System Profile Settings ------------------------------------------ System Profile : Performance CPU Power Management : Maximum Performance Memory Frequency : Maximum Performance Turbo Boost : Enabled C1E : Disabled C States : Disabled Monitor/Mwait : Enabled Memory Patrol Scrub : Standard Memory Refresh Rate : 1x Memory Operating Voltage : Auto Collaborative CPU Performance Control : Disabled A Dell mailing list post describes the symptoms almost perfectly. Dell suggested that the author try using the Performance profile, but that didn't help. He ended up applying some settings in Dell's guide for configuring a server for low latency environments and one of those settings (or a combination thereof) seems to have fixed the problem. Kernel.org bug #36182 notes that power-limit interrupt debugging was enabled by default, which is causing performance degradation in scenarios where CPU voltage regulation is kicking in. A RHN KB article (RHN login required) mentions a problem impacting PE r620 and r720 servers not running the Performance profile, and recommends an update to a kernel released two weeks ago. ...Except we are running the Performance profile... Everything I can find online is running me in circles here. What's the heck is going on?

    Read the article

  • What does "single-bit ECC errors were detected on the RAID controller" mean?

    - by jsp
    I have a Dell T7600 with a Perc H710P RAID controller and 4 attached 3TB drives. Over the past few months the RAID controller has been intermittently reporting errors on boot: "no boot device found", "adapter at baseport is not responding", disks frequently reported as missing or failed. I have since replaced the RAID controller, the 4 hard drives, and finally the system's motherboard. After replacing the motherboard and rebooting a few times, I got the error Single bit ECC errors were detected on the RAID controller. Please contact technical support to resolve this issue. After rebooting about 20 more times, I haven't seen the ECC error. The system seems otherwise OK, except for the fact that the disk fans will sometimes start blowing at full blast when the the system is sitting completely idle and not stop until I reboot. Are the ECC errors in memory on the RAID controller? Or, does the RAID controller map in system memory, and the ECC errors are really in system memory? Or, are the ECC errors in the 1GB cache that resides in the RAID controller?

    Read the article

  • Static IP settings on Windows 2003 server not getting saved

    - by Prashant Mandhare
    We have a Dell PowerEgde 1950 server with Broadcom NetXtreme gigabit ethernet card, and we are facing a strange problem with static IP assignment. When we assign a static IP to this broadcom NIC, settings are not getting saved. Following are the steps to reproduce problem open TCP/IP properties window for broadcom NIC manually enter static IP address and other details like gateway, DNS, etc. apply and close properties dialog. re-open TCP/IP properties windows, you will see your static IP settings lost and changed to "obtain IP address manually" but when checked using ipconfig command, you will still see your same static IP settings but, when checked using ipconfig command after rebooting server, these static ip settings are completely gone and automatically obtained IP is assigned Supplementary information: Recently we had formatted this server and installed windows 2003 from OEM windows setup CD (not from OS installation CD received from Dell). After windows installation was over, broadcom NIC drivers were installed.

    Read the article

  • JBOD with PERC H810

    - by primero
    I'm wondering if anybody has ever used Dell storage products like the MD3220 array in a JBOD configuration. From what I can tell only perc h810 will work for external JBOD but that is not terribly specific, and for some reason I couldn't find many examples on the web of people configuring dell storage products as JBOD. My question is: Is it possible to connect to am MD3220 array, or other Dell arrays using a PERC h810 controller and use it as JBOD, and if so do I have to configure every disk in the array as a RAID 0 volume?

    Read the article

  • New Dell PE R710 - Storage Question

    - by rihatum
    Hi All, Dell PE R710, received from Dell in the following state : Windows Disk 0 1800GB ( Volume C & D ) Windows Disk 1 526 GB (Volume E ) Perc6i Integrated Raid Controller 6 x 500GB Nearline SAS 7200RPM HDDs Raid 5 Configuration with two Virtual Disks I have installed Dell open Manage and it shows the following : Virtual Disk 0 - State : Background Initialization ( 7% ) Virtual Disk 1 - State : Background Initialization ( 25% ) Now when I click on Virtual Disk 0 it shows me all 6 Disks and the same happens when I click on Virtual Disk 1 it displays all 6 disks. But when I click on Storage Perc6i Connector 0 I get 4 Physical disks with the following numbers : Physical Disk 0:0:0 Physical Disk 0:0:1 Physical Disk 0:0:2 Physical Disk 0:0:3 When I click on Storage Perc6i Connector 1 I get 2 Physical Disks Listed in the following way : Physical Disk 1:0:4 Physical Disk 1:0:5 I am a little confused in this description, does this 1:0:4 interprets to Controller1, Disk4. Does this integrated raid card have two controllers coming out of it ? Also, When I first switched on the machine, the boot partition was showing 1GB Available out of 40GB, now its showing 38GB available out of 40GB. Is this because the Virtual Disks are still Initializing ? Any recommendations or suggestions ? Also, this server have 6 x 500GB NearLine SAS Hard drives, what would be a good raid config ? We are planning to use it for Hyper-V with quite a few (7 or 8) virtual servers, your suggestions would be helpful. Also, while the virtual disks are in a initialization state, can I destroy and re-create the raid configuration ? I would have to do it at the BIOS CTRL-M ? Thanks and Regards

    Read the article

  • Can't Remote into Windows Server

    - by Brian
    Hello, I have a Dell server wired into the router. I was able to connect to it with my laptop (laptop is wireless) before my router died. My verizon router went kaput, and I got everything else back up and running on the wireless network other than the remoting in feature, even though I can access the server through windows explorer just fine. Any ideas why? What do I need to check? UPDATE: Interesting scenario, Network Discovery is off; I turn it on and save, but for some reason, even after that, network discovery is turning itself off... no idea why that is happening? Thanks.

    Read the article

  • Dell R610 memory configuration for all 12 slots

    - by Neal
    I purchased 12 sticks of RAM on eBay to go into a Dell R610 server. The RAM is ECC REG PC3-12800 DDR3-1600 yet when I occupy all 12 slots with this ram I get the following error on boot: MEMORY Initialization Warning: Memory Size May be Reduced MEMBIST failure – The following DIMM has been disabled by Bios: DIMM B2 MEMBIST failure – The following DIMM has been disabled by Bios: DIMM B5 I am using all of the latest versions, BIOS, etc. I am using 2 x x5660 processors. What is causing this issue and is it correctable? If this RAM is incorrect what is correct to maximize the RAM on this server? Thank you.

    Read the article

  • Getting around the lack of GPT support with CentOS 5.4

    - by sxanness
    Here is my issue and I hoping that there is someone out there that has an answer so I don't end up stuck here at my co-location all day. Last night I came here and upgraded a server (Dell 2970) to have four 1TB Hard Drives in RAID 5 which leaves a 3TB block. I tried to partition this but keep getting an error that GPT is not supported so I found a site online telling me I need to run the dd command and right random data to /dev/sda. This is great (if it works) but taking forever. I have two more machines to upgrade today and not a chair in site. Does anyone have advice on how I can avoid this issue beforehand? Thank You for your advice and support.

    Read the article

  • IPMI sdr entity 8 (memory module) only showing 3 records?

    - by thinice
    I've got two Dell PE R710's - A has a single socket and 3 DIMMs in one bank B has both sockets and 6 (2 banks @ 3 DIMMs) filled The output from "ipmitool sdr entity 8" confuses me - according to the OpenIPMI documentation these are supposed to represent DIMM slots. Output from A (1 CPU, 3 DIMMS, 1 bank.): ~#: ipmitool sdr entity 8 Temp | 0Ah | ok | 8.1 | 27 degrees C Temp | 0Bh | ns | 8.1 | Disabled Temp | 0Ch | ucr | 8.1 | 52 degrees C Output from B (2 CPUs, 3 DIMMS in both banks, 6 total): ~#: ipmitool sdr entity 8 Temp | 0Ah | ok | 8.1 | 26 degrees C Temp | 0Bh | ok | 8.1 | 25 degrees C Temp | 0Ch | ucr | 8.1 | 51 degrees C Now, I'm starting to think this output isn't DIMMS themselves, but maybe a sensor for each bank and something else? (Otherwise, shouldn't I see 6 readings for the one with both banks active?) The CPU's aren't near 50 deg C, so I doubt the significantly higher reading is due to proximity - Is anyone able to explain what I'm seeing? Does the output from my ipmitool sdr entity 8 -v here on pastebin seem to hint at different sensors? The sensor naming conventions are poor - seems like a dell thing. Here is output from racadm racdump

    Read the article

  • Moving Farm to co-location hosting - network settings requirements

    - by Saariko
    I am moving my farm (2 Dell's R620) to a co-location hosting service. I am trying to figure out the secure way to have my network settings The requirements are: VM1 is the working HOST, includes: esxi 5.1, vSphere, 4 clients (w2008r2 all) VM2 has esxi 5.1 installed, and a single machine with Veeam Backup and copy 6.5 - keeping a copy of VM1 clients on the VM2 internal storage (this solution is due to a very small budget - in case of failure on Host 1 - can redirect IP's) Only 2 VM clients require network address and access from the WWAN - ISP provides IP's range for them (with Gateway and DNS) I need connection to the iDrac's from my office (option to create a VPN-SSL tunnel) Connection to the vSphere appliances I want to be able to RDP to the VM clients The current configuration is that each host has the iDrac dedicated nic connected , and another (NIC #1) connected - with a static IP on 192.168.3.x The iDrac's have a static IP from the same network range (19.168.3.x) It will look something like this: My thoughts: On NIC#2 of both hosts I will connected a crossed cable I will give each VM clients that needs internet access a 2ndry VM network with the assigned IP from the ISP open only to web - can not access from the My Question: Should I give IP's (external) to the machines who DO NOT require WWAN Access? - I can't see a way to RDP to them directly if not. Should I use the crossed cable? or just plug NIC #2 to the switch? Will this setup even work? What do I need to verify? What Virtual nic's and/or switches should I create on the Hosts?

    Read the article

  • Dell PE R710 Lifecycle Controller

    - by rihatum
    Hi All, How would one use the dell lifecycle controller on the new R710 Servers ? I have seen demos on youtube and it can install linux, windows from there without inserting the installation discs ? I am on the same LAN as the server and have setup iDrac Express (we dont have drac enterprise). Any suggestions ? Thanks

    Read the article

  • Installing VMware ESXi 4.0 on Dell 1950: Cannot open vmkboot.gz

    - by rlandster
    I am trying to install VMware ESXi 4.0.0 U1 on a Dell 1950 server via a bootable CD-ROM. I keep getting this error right at the start: Cannot open vmkboot.gz I checked that the CD-ROM drive is not to blame by installing Debian Etch using that drive. I tried several different versions of ESXi (3.5, 3.5 Dell edition, 4.0 Dell edition) and they all give me an error at the same place. I also tried installing from a USB "thumb" drive but got the same error. I checked with the VMware HCL (Hardware Compatibility List) and the Dell 1950 is listed as being compatible. Here are some server details: Two 1.6 GHz Xeon 5110 CPUs (ID: 06-0F-B) BIOS version 2.2.6 Any ideas on what might be the issue?

    Read the article

  • Disable "System Memory Testing" via OMSA 6.4.0

    - by EGr
    Is it possible to disable system memory testing via OMSA 6.4.0? I can only find ways to do it using newer versions of OMSA; and I can't even see the setting in 6.4.0. I have quite a few machines that I want to disable this (BIOS) setting on, but I don't want to have to install the new OMSA and reboot. My intentions are to disable the setting so that when the systems are rebooted in the future, they don't need to go through the system memory testing. If it is possible to disable this another way, without OMSA or manually changing the BIOS settings, I would be open to that as well.

    Read the article

  • Video issues with old server running Boxee

    - by Skaughty
    I have a old Dell Power Edge 1650 1U rackmount server running Windows XP. Dual 1.3 ghz Processors and 1 GB of RAM. I would like to run Boxee on it, but the 8mb integrated video card will not support it. The font within Boxee just comes up as blocks of color. I have a PCI Radion R9000 dual out video card. However when I plug it in I can not get video signal on any of the VGA outs. Is it possible to upgrade the video card on this old of a server, or is it possible to make it work with the older integrated video?

    Read the article

  • Best way to execute a command after Linux system halt

    - by Lukas Loesche
    Problem: The SSDs in our servers require a power cycle (i.e. off/on, not reset/warm reboot) after a firmware update. Thoughts: Using 'ipmitool chassis power cycle' I can cycle the server's power. However this would cut the power while the system is still running, filesystems are mounted, etc. What I basically want is a delayed power cycle so the system has a change to halt. But I guess that would have to be implemented on the server's IPMI board, so it's not really an option. My initial idea was to dynamically create a ramdisk containing the tool and libs and somehow integrate that into the halt process. I saw there's a /etc/init.d/halt, so that would be my starting point. Although I believe the kernel at some point in the shutdown process starts to kill off remaining processes. So I'm not even sure if that's a viable way. Question: What would be the best way to execute ipmitool (or any other command), after the system has halted and all regular filesystems are unmounted?

    Read the article

  • Dell 2970 - HP 1/8 G2 autoloader keeps falling off LSI 2032 SCSI chain

    - by middaparka
    I've a somewhat irritating problem with a Dell 2970 that has a HP 1/8 G2 autoloader (the Ultrium LTO 2 model) attached to the Dell/LSI 2032 non-RAID SCSI card. In essence, sometimes the autoloader/drive completely fails to appear on the SCSI chain (i.e.: there's neither a media changer or tape drive present within the device manager) and sometimes it appears but then subsequently disappears at a seemingly random (yet always inconvenient) time, resulting in backup failures. On most occasions, there are simply no errors logged in the system event log, but I did manage to capture a series of LSI_SCSI event ID 11 ("The driver detected a controller error on \Device\RaidPort0") errors followed by an event ID 129, ("Reset to device, \Device\RaidPort0, was issued") error during testing. I've tried two different cables, both with the same effect – sometimes the autoloader appears (for a while), sometimes it's completely absent. There's only one terminator I've tried to use, but as I've since successfully tested the autoloader on multiple occasions (albeit via a Adaptec U160 card on a different machine), my gut feel is that the issue doesn't lie with the terminator, or indeed the autoloader itself. As such, I'm just wondering if anyone has any ideas? It's most likely not relevant, but this is all under Windows SBS 2008, running Backup Exec 12.5 SBS edition (the Dell version), both fully patched. Addidtionally, the autoloader is running the latest firmware. It's been a while since I've dealt with anything SCSI, so all suggestions will be gratefully, gratefully received.

    Read the article

  • Using a non-validated SED on a Dell R720

    - by a coder
    We were given a Dell R720 a couple years ago, and the machine currently has standard 300GB 3.5" SAS 15k drives. Our RAID controller is a Perc H710. We need to update our disks to FIPS 140-2 certified SED. According to Dell, they have only one tested/validated FIPS SED for this machine/controller, but it is a 7200rpm 3.5" unit. I'm showing that Dell offers a 600GB 15k FIPS SED in 3.5" configuration (Dell part number 342-0605), but they say they haven't validated or tested to know if it works. They informed us that we would not void our warranty in using this non-validated drive. How likely is it that our R720 with H710 controller will work with the non-validated drive? Are there significant differences in how drive manufacturers build SED that would prevent them from working consistently across different controllers?

    Read the article

  • Removing RAID on a DELL power-edge server

    - by Simon Callan
    We have a Dell Power-edge T110 server, with either a PERC S100 or S300 raid controller (I suspect S100), and 2 x 500GB SATA hard discs. These discs are running in RAID-1 configuration, (either 1 or 2 virtual discs), and on top of this, we have the C and D drives. As we are running low on disc space, we are looking at dropping the RAID to get some disc space back. Is it possible to split the discs back into 2 seperate hards discs that the OS can see, without losing all the data on the drives? Even better, would it be possible to split the D: drive, leaving the OS C: drive in RAID1 configuration?

    Read the article

  • Monitoring Dell/HP Servers Running ESXi (Free)

    - by Untalented
    What are you all doing to monitor ESXi servers that run the free edition? With the lack of SNMP support, it seems fairly limited to me. What'd I'd like to be able to do is get some type of alert when a drive or other hardware fails. I've seen a few articles on getting OpenManage installed on an ESXi box (to rebuild an array), but it seems to be quite a pain as well. Even if I get OpenManage working, I won't have alerts without SNMP. Any comments, input, or guidance would be greatly appreciated.

    Read the article

  • replacement drive cage for power edge R710

    - by bumble_bee_tuna
    Hi I'm performance tuning a DB server its a Dell R710 there is a very significant I/O bottleneck. Unfortunately the server was purchased with the 6 x 3.5 inch sata configuration which doesn't give me the leeway I need to address the issue. Before going to DAS does anyone know if it is possible to purchase a replacement front drive enclosure ? I know the server is configurable with something like 12 or 16 2.5 inch drives and it appears to be modular ? I tired contacting dell but the offshore parts department reps are not very bright lol. Thanks.

    Read the article

  • Dell Power Edge R515 - Replacing a Bad Hard Drive in a RAID

    - by LonnieBest
    I've ordered a new hard drive to replace a bad one in a Dell Power Edge R515. The manual covers obvious topics regarding physical replacing of hard drives, but I've never done this before on a production server where RAID is involved. I've heard people talk about this topic, and I've heard that some servers have RAID controllers that are smart enough to allow you to just put in the new drive (hot swap), and then the server will know automatically how to rebuild that drive to be what the old one was to the system. Where do I find the proper procedure for replacing a failed hard drive on a live production Dell Power Edge R515? Can someone with experience tell me how easy or hard this usually is?

    Read the article

  • Can't Remote into Windows Server

    - by Brian
    Hello, I have a Dell server wired into the router. I was able to connect to it with my laptop (laptop is wireless) before my router died. My verizon router went kaput, and I got everything else back up and running on the wireless network other than the remoting in feature, even though I can access the server through windows explorer just fine. Any ideas why? What do I need to check? UPDATE: Interesting scenario, Network Discovery is off; I turn it on and save, but for some reason, even after that, network discovery is turning itself off... no idea why that is happening? Thanks.

    Read the article