  • After a week of smooth running, my Dell t310 servername reverted to the service tag and screwed everything up!

    - by user779887
    Has this happened to anyone else? Began having a tremedous amount of problems with our brand new Dell SBS 2011 T310 server and after nearly 15 hours will Dell support, they determined that the server name hade reverted to DXXXXXXXX ("D: + the service tag). The Dell tech said that this was a major major problem. I'm the only person with any access to the machine and I didn't attempt to change the server name. The tech said it didn't look as if anyone had hacked the box but something had replaced "OurCompanyServer" with "DXX12XX" It would seem to me, simply changing the server name back to what I originally had would correct the problem, but the Dell tech said it wasn't that easy. Anyone encounter this?

    Read the article

  • Why would Linux VM in vSphere ESXi 5.5 show dramatically increased disk i/o latency?

    - by mhucka
    I'm stumped and I hope someone else will recognize the symptoms of this problem. Hardware: new Dell T110 II, dual-core Pentium G860 2.9 GHz, onboard SATA controller, one new 500 GB 7200 RPM cabled hard drive inside the box, other drives inside but not mounted yet. No RAID. Software: fresh CentOS 6.5 virtual machine under VMware ESXi 5.5.0 (build 174 + vSphere Client). 2.5 GB RAM allocated. The disk is how CentOS offered to set it up, namely as a volume inside an LVM Volume Group, except that I skipped having a separate /home and simply have / and /boot. CentOS is patched up, ESXi patched up, latest VMware tools installed in the VM. No users on the system, no services running, no files on the disk but the OS installation. I'm interacting with the VM via the VM virtual console in vSphere Client. Before going further, I wanted to check that I configured things more or less reasonably. I ran the following command as root in a shell on the VM: for i in 1 2 3 4 5 6 7 8 9 10; do dd if=/dev/zero of=/test.img bs=8k count=256k conv=fdatasync done I.e., just repeat the dd command 10 times, which results in printing the transfer rate each time. The results are disturbing. It starts off well: 262144+0 records in 262144+0 records out 2147483648 bytes (2.1 GB) copied, 20.451 s, 105 MB/s 262144+0 records in 262144+0 records out 2147483648 bytes (2.1 GB) copied, 20.4202 s, 105 MB/s ... but after 7-8 of these, it then prints 262144+0 records in 262144+0 records out 2147483648 bytes (2.1 GG) copied, 82.9779 s, 25.9 MB/s 262144+0 records in 262144+0 records out 2147483648 bytes (2.1 GB) copied, 84.0396 s, 25.6 MB/s 262144+0 records in 262144+0 records out 2147483648 bytes (2.1 GB) copied, 103.42 s, 20.8 MB/s If I wait a significant amount of time, say 30-45 minutes, and run it again, it again goes back to 105 MB/s, and after several rounds (sometimes a few, sometimes 10+), it drops to ~20-25 MB/s again. Plotting the disk latency in vSphere's interface, it shows periods of high disk latency hitting 1.2-1.5 seconds during the times that dd reports the low throughput. (And yes, things get pretty unresponsive while that's happening.) What could be causing this? I'm comfortable that it is not due to the disk failing, because I also had configured two other disks as an additional volume in the same system. At first I thought I did something wrong with that volume, but after commenting the volume out from /etc/fstab and rebooting, and trying the tests on / as shown above, it became clear that the problem is elsewhere. It is probably an ESXi configuration problem, but I'm not very experienced with ESXi. It's probably something stupid, but after trying to figure this out for many hours over multiple days, I can't find the problem, so I hope someone can point me in the right direction. (P.S.: yes, I know this hardware combo won't win any speed awards as a server, and I have reasons for using this low-end hardware and running a single VM, but I think that's besides the point for this question [unless it's actually a hardware problem].) ADDENDUM #1: Reading other answers such as this one made me try adding oflag=direct to dd. However, it makes no difference in the pattern of results: initially the numbers are higher for many rounds, then they drop to 20-25 MB/s. (The initial absolute numbers are in the 50 MB/s range.) ADDENDUM #2: Adding sync ; echo 3 > /proc/sys/vm/drop_caches into the loop does not make a difference at all. ADDENDUM #3: To take out further variables, I now run dd such that the file it creates is larger than the amount of RAM on the system. The new command is dd if=/dev/zero of=/test.img bs=16k count=256k conv=fdatasync oflag=direct. Initial throughput numbers with this version of the command are ~50 MB/s. They drop to 20-25 MB/s when things go south. ADDENDUM #4: Here is the output of iostat -d -m -x 1 running in another terminal window while performance is "good" and then again when it's "bad". (While this is going on, I'm running dd if=/dev/zero of=/test.img bs=16k count=256k conv=fdatasync oflag=direct.) First, when things are "good", it shows this: When things go "bad", iostat -d -m -x 1 shows this:

    Read the article

  • Dell PowerEdge 1600SC Server won't boot from Fedora 12 DVD because of CD only drive.

    - by studiohack23
    Dell PowerEdge 1600SC Server won't boot from Fedora 12 DVD in the drive because it only supports CDs as I found out after the fact. I'm a complete novice @ servers, so if you need more detail, let me know, and I'll try to provide it. This server is around 4-6 years old. it has "PXE" boot, not sure what that means? This particular server has 3 RAID hard drives. As far as I know, they have all been wiped. I looked up the service tag on Dell, and it has: Compact Disk Drive, 650M, I Internal, Half Height, 48X, BlackHitachi LG Data Storage as its CD drive. Thus, the CD drive does not support DVDs, so installation will have to be via a live CD. However, I'm trying to put Amahi Home Server (http://www.amahi.org/), and Live CD/USB stick installs are not recommended unless one is an expert Linux user. any suggestions as to how to get around this? PROBLEM SOLVED! THANKS for all the help!

    Read the article

  • Oracle VM Forum????????!?????????????? "??????·????" ??????

    - by rika.tokumichi
    ??????OTN????????? 2010?5?18?????????????????Oracle VM Forum?????????? ?????????????????????????????????? ?????????????????????????????????·?????????????????????????????????????????????????????????????????????????·???????????????????????????????????????????? ??????????4?????????? ????????(?????)???????????·???????~???????????????? 5????~ ?????!????????·????????????????????? ????????????·?????????~???????????????????????~ ????????????????????~????????·????????????????~ ????????????????? ????????????????????????????????OTN?????????????????????????????????????????????????????????Fusion Middleware?????? - Fusion Middleware???????? ????????????????????????????????^^ ???????????????????????????????????? ------------------------------ ?????!????????·????????????????????? ????????????????????????????Xen???????????????? ???Oracle VM for x86?Xen???????????????Xen 4.0????????Oracle VM???????????????????????????????????????Dell PowerEdge R910(CPU 32?????? 64GB)????????? ??????????????????VM????????????????????????????????????????????·???????????????????? ??????????4GB??????·????????????????????·????????????????? ???????VM1???????????????????????VM 30????VM 60?????????????????????? ?????????????????????????????????????VM?????????????????????? ?????????????Self-Ballooning?Transcendent Memory?????????????????????????????????????????????????????????? >Xen??????????????? ????????????????????????Dell PowerEdge R810?????????????????????2U??????????????CPU 32??????????·????32??????????? PowerEdge R810> ----------------------------- ????????????????????~????????·????????????????~ ???????????????????(AP)???????????????????????????????????????????????????????????????????????????????????????????????? ????????????AP????????????????????????? ?????????????????????????????????AP????·????????????????????????????????????????AP·????·????????????????????????????????????? ???????????EC???????????????????????????????????? ????????????????????2?????? ???Oracle Virtual Assembly Builder? ????(Web?AP?DB)????????????????????????????????????????????? ???Oracle WebLogic Server on JRockit Virtual Edition? ????OS?????????????????JVM?????OS????????????????????(?????????????)?????????????????????????? ----------------------------- ??????????????????? >?????????????? ?????????????(??????)?????????????????????????? ?????????????????????????! ?????????????????????????????????????????????????????????

    Read the article

  • Computer Comparison - which is "better"

    - by David Murdoch
    A company I work with recently replaced their old server and gave it to me. Their old server is a Dell PowerEdge 2600. I've been playing with the machine and even installed Windows Server 2008 on it...and it seems to run it pretty well. Here are the specs for the two machines: Dev Machine: AMD Athlon64 3000+ 2.38 GHz (overclocked from 1.8GHz [@ 280x8.5] - it is stable-ish) Memory (RAM): 1x1GB OCZ PC3200 (Dual-Channel) 300GB HD OS: Windows XP Pro (32bit) SuperPi 1M digit test: 40 seconds Dell PowerEdge 2600 Server: Intel Xeon CPU 2.8GHz 2.8GHz Memory (RAM): 512MBx2 (PC2700, not dual channel) 68GB HD (RAID 5) OS: Windows Server 2000 (32bit) SuperPi 1M digit test: 56 seconds [using 1 processor] (Themes and Aero-Flass UI turned off, of course) I use my computer to regularly run Photoshop CS5, Illustrator CS5, Flash CS5, 5 browsers (Chrome, FF, IE, Safari, Opera), iTunes, Visual Studio 2010, and Kaspersky Internet Security 2010 [sometimes simultaneously :-) ]. The SuperPi test has my dev machine coming in about 30% faster than the Server machine...though this could be due to the server running "Vista" with background processes prioritized. Do you think it would be realistic/advantageous for me to move from my dev machine to the Dell PowerEdge 2600? Is it possible to install additional DVD drives/burners on the server? Can I install my internal 300 GB hard drive on the server? Can I add some USB 2.0 ports? Note: I'll probably install Win XP Pro on the dev machine if I do switch. If not, are there any creative and useful way for me to take advantage of this server (with the goal of faster computing)?

    Read the article

  • Converting an Small Business Server to a Workstation

    - by noway
    I am planning to buy a Dell PowerEdge T110 Server and convert it to workstation similar to Dell PowerEdge Precision T1700. The reasoning behind is the cost, if I do it by myself, it costs two times cheaper. However, I wonder what might go wrong in this way? The things I have thought of are: Client OSes are not officially supported. There might be some driver problems. The chasis is designed to be a server case, so there are not many useful inputs in the front side of the case. The server boots slower than usual PCs. What might else be a problem?

    Read the article

  • Supermicro motherboards and systems

    - by jchang
    I used to buy SuperMicro exclusively for my own lab. SuperMicro always had a deep lineup of motherboards with almost every conceivable variation. In particular, they had the maximum memory and IO configuration that is desired for database servers. But from around 2006, I became too lazy to source the additional components necessary to complete the system, and switched to Dell PowerEdge Tower servers. Now, I may reconsider as neither Dell or HP are offering the right combination of PCI-E slots. Nor...(read more)

    Read the article

  • Dell Perc 6i with FreeBSD 8.1 errors with mfi0: COMMAND xxxxxxxx TIMEOUT AFTER xxx SECONDS

    - by jDempster
    We've recently bought two Dell PowerEdge R710 servers with Perc 6i controllers and 6x 135GB SAS Drives. We'd done some pretty extensive testing on a Dell PowerEdge R510 server with a Perc 6i and 4x 135GB SAS Drives running FreeBSD 8.1 for it's wonderful ZFS support and mfiutil. We hadn't had any problems with the R510 and had got to a point where we where happy with the performance of ZFS. Since running FreeBSD 8.1 on the R710 we've been getting errors from the RAID controller. mfi0: COMMAND 0xffffff80005d1770 TIMEOUT AFTER 6178 SECONDS This usually brings the system to a stand still. But it doesn't always happen, and performs very well up until it does happen. We've been running the disk as 3 mirrored drives striped in ZFS. So far we've noticed that running the drives with RAID10 on the RAID seems to work without errors (still testing). At first I thought hardware error as we'd been running FreeBSD on the R510 with the same controller without any issues. But both R710 have the same issue. All controllers are running the same firmware.

    Read the article

  • Intermittent "Lost connection to MySQL server at 'reading initial communication packet'"

    - by db2
    Our web environment consists of two servers. Web front-end. Dell PowerEdge R610, RHEL 5.5, Apache 2.2.17, php 5.2.14. Database server. Dell PowerEdge R710, Windows 2008 R2 Standard x64, MySQL 5.5.11-log x64. Normally these two work perfectly fine together. However, when I try to get them talking via a dedicated LAN on their secondary NICs (each machine has four of them), things get flaky. I have NIC #2 on both machines configured on the 172.16.1.0/24 subnet, with no gateway or DNS servers (obviously, since it's just those two systems), and I put the private IP address of each machine into the hosts file of the other. The routing tables on both machines look okay after I do this. I've tried this with both a crossover cable draped directly between the two NICs, and also via a dedicated vlan on the switch in the rack. In either case, I get intermittent connection problems. It's a fairly small percentage of connections that fail, but it's enough to cause a significant problem, and I have to switch back to the main network connection, which will contend with all the other traffic and hosts on the switch. The full error message that appears in the application log: SQLSTATE[HY000] [2013] Lost connection to MySQL server at 'reading initial communication packet', system error: 110 Am I doing something really dumb that's causing this to not work properly? Anything I can check in MySQL that would explain why it's failing to connect occasionally?

    Read the article

  • Dell PERC 5 - RAID-10 keeps rebuilding drive 2 every day

    - by raid question
    I have a Dell PowerEdge 2950 with this card: RAID bus controller [0104]: Dell PowerEdge Expandable RAID controller 5 [1028:0015] and six disks in a RAID-10. I replaced drive 2, because it didn't show up, and then it started to rebuild itself: root@backup01:~# megaraidsas-status -- Arrays informations -- -- ID | Type | Size | Status a0d0 | RAID 10 | 5587GiB | DEGRADED -- Disks informations -- ID | Model | Status | Warnings a0e8s0 | ATA ST2000DM001-9YN1 1863GiB | online | errs: media:0 other:5393 a0e8s1 | ATA ST2000DM001-9YN1 1863GiB | online | errs: media:0 other:5394 a0e8s2 | ATA ST2000DM001-1E61 1863GiB | rebuild | errs: media:0 other:99 a0e8s3 | ATA ST2000DM001-9YN1 1863GiB | online | errs: media:0 other:5393 a0e8s4 | ATA ST2000DM001-9YN1 1863GiB | online | errs: media:0 other:5393 a0e8s5 | ATA ST2000DM001-9YN1 1863GiB | online | errs: media:0 other:5393 The rebuild finishes, then the virtual drive becomes optimal, and drive 2 goes online. Then once a day, drive 2 acts like it's been removed, and the rebuild starts all over again. How do I make this once a day rebuild stop? Event Description: Removed: PD 02(e1/s2) Event Description: Removed: PD 02(e1/s2) Info: enclPd=08, scsiType=0, portMap=04, sasAddr=1221000002000000,0000000000000000 Event Description: State change on VD 00/0 from OPTIMAL(3) to DEGRADED(2) Event Description: VD 00/0 is now DEGRADED1 Event Description: State change on PD 02(e1/s2) from ONLINE(18) to FAILED(11) Event Description: State change on PD 02(e1/s2) from FAILED(11) to UNCONFIGURED_BAD(1) Event Description: Background Initialization failed on VD 00/0 Event Description: Inserted: PD 02(e1/s2) Event Description: Inserted: PD 02(e1/s2) Info: enclPd=08, scsiType=0, portMap=04, sasAddr=1221000002000000,0000000000000000 Event Description: PD 02(e1/s2) is not a certified drive Event Description: State change on PD 02(e1/s2) Event Description: State change on PD 02(e1/s2) from UNCONFIGURED_GOOD(0) to OFFLINE(10) from UNCONFIGURED_BAD(1) to UNCONFIGURED_GOOD(0) Event Description: Rebuild automatically started on PD 02(e1/s2) Event Description: State change on PD 02(e1/s2) from OFFLINE(10) to REBUILD(14)

    Read the article

  • Compatibility of ESX 4 and LTO 3 with LSI2032 Dell Power Edge

    - by dbaur
    Hello, does anybody know something about the compatibility of an LTO 3 Tapedrive (PV HH LTO 3 400GB) attached to an LSI2032 SCSI-Controller? These devices are added to an Dell PowerEdge T610 Server which is listed in the certified Compatibility Guide. I can`t find any information for this controller and this tapdevice. Or are they automaticly compatible because they are options for an compatible Server? greetings Dennis

    Read the article

  • Is it better to have more small ram chips or fewer large ones?

    - by Alex Andronov
    I am currently building a new server. I have options between say 32GB Memory for 2 CPUs, DDR3, 1066MHz (8x4GB Dual Ranked RDIMMs) and 36GB Memory for 2 CPUs, DDR3, 1066MHz (18x2GB Dual Ranked RDIMMs) Both at the same price. Should I go for the higher ram amount or the fewer chips? This will be for a Dell PowerEdge R710 with two Intel® Xeon® E5530, 2.4Ghz, 8MB Cache, 5.86 GT/s QPI, Turbo, HT Thanks

    Read the article

  • Virtual LTSP server with KVM

    - by phil
    I want to setup a kvm-based LTSP appliance with Ubuntu 10.04 (server/desktop for ltsp) on a Dell PowerEdge 2900 for ~10-15 clients. People will mostly use Firefox, Thunderbird, OpenOffice and Qcad. Does someone have any experience with this setup? I've had a similar setup with VMware Server 2 and Ubuntu 8.04. How good/bad is kvm compared to VMware for a LTSP appliance? Shall I stick with VMware or can I switch to KVM?

    Read the article

  • SCSI drives not showing up in Linux CentOS 4

    - by Mohammad
    So I have a poweredge 6650 with Perc 3 installed. on the first channel of raid controller I have 2x 73gb configured in raid 1. On the second channel I have two 300GB drives that are stand alone. The two 300gb drives do not show up in linux, (no /dev/sdb*)... Can perc 3 support non-raid and raid drives combined? Is there any settings I may be missing? Thanks in advance :)

    Read the article

  • Slow Write Speed on ESXi host

    - by Gregg Leventhal
    I have an ESXi 5.0 free host with an internal datastore of 7.2K 5 disk RAID 5 using a PERC 710 mini RAID controller in a Dell Poweredge R620 Server with 32GB Ram and a 12 Core Xeon. I seem to get slow write speeds in the guests so I checked out ESXTOP and I see 15MB/s write speed there on this host, which is comprable to the guests. What could be causing such horrible write speeds? Is RAID 5 really this slow to write??

    Read the article

  • Raid 5 GPT Partitioning

    - by user39325
    I have a Dell Poweredge r710 server with five 1 TB disks. All of them are in RAID 5. I was trying to install Centos but it says "Your boot partition is on disk using GPT Partition..." I read somewhere that centos can't install on a disk larger than 2TB, so I made some partitions smaller, but it's not working. PS, I am going to install Proxmox on that, but Proxmox also won't accept disks larger than 2TB.

    Read the article

  • Unable to recognize hard drive after replacing a drive

    - by Peter Schriver
    I have a Poweredge 830 that I had been using with 1 OS Sata drive and 3 data drives. One of the drives had some failing sectors so I replaced it with a different drive. For some bizarre reason the computer would not reboot so I disconnected all of the media drives and did a clean reinstall on the OS drive. Only the boot drive and one of the media drives are now recognized by my Bios. Drive 0 and 2. Drive 1 and 3 are listed in the Bios as "Unkown Device" Any help would be appreciated I think there may be something wrong with the install. For some reason when I attempt to change the display it says I have a laptop.If you think a reinstall is in order I will try that.

    Read the article

  • Using a Dell DRAC virtual console through a NAT firewall

    - by jetboy
    I have two Dell Poweredge R210 servers, both running Ubuntu 10 Server x64. Server A has a Dell DRAC ILO card (on 172.16.96.91), and both the server and the DRAC use Server B as a gateway (with server B's WAN IP being xxx.xxx.xxx.xx). Server B uses the following NAT rules in IPTables to route traffic through to Server A's DRAC: *NAT --append PREROUTING --in-interface eth1 --protocol tcp --destination xxx.xxx.xxx.xx --destination-port 8019 --jump DNAT --to-destination 172.16.96.91:443 --append POSTROUTING --out-interface eth1 --jump SNAT --to-source xxx.xxx.xxx.xx This works fine for accessing Server A's DRAC via Server B, apart from the Java virtual console. This fails with the following error: com.sun.deploy.net.FailedDownloadException: Unable to load resource: https://xxx.xxx.xxx.xx:443/software/avctKVM.jar at com.sun.deploy.net.DownloadEngine.actionDownload(Unknown Source) etc. I know that the Java console uses port 5900, and possibly ports 83 and 5891. Can anyone help me in getting this working?

    Read the article

  • Broadcom NIC Teaming w/ 802.3ad and Dell Powerconnect 2824

    - by Carltoncl
    We have a Poweredge R210 running WS2K8R2. The server has two Broadcom 5716C NICs running Broadcom BASP. I can team the NICs using the 802.3ad protocol on the server end no problem. I have no VLAN. Now I go to the 2824 switch (default settings all round) running in managed mode and create a LAG with ports g1 and g2. As soon as I add these ports, I lose the ability to send traffic to or from the server. I am much more of a server guy than a networking guy, what am I doing wrong here? Server Static IP Address: 10.10.61.15 Network mask: 255.255.255.0 Gateway: 10.10.61.51 The 2824 switch has an IP address of 10.10.61.51 and in turn has its gateway as our firewall server running ISA Server at 10.10.61.50.

    Read the article

  • RAID 5 RECONSTRUCT with RAID Reconstructor

    - by user22914
    I have Dell Poweredge server 2600 with Raid 5 in 3 hard drive Scsi 36gb each, it was fail to boot sinc the third drive is offline. I attached Sata card adapter to Sata hard drive and install OS SERVER 2003 to it, downloaded drivers for Raid and everything goes fine when I use recovery data software called "GetDataBack" from here http://www.runtime.org/data-recovery-software.htm but the problem that not all data recovered, I am still looking for importants data with about 5 GB size. I have another software called "RAID Reconstructor" from "http://www.runtime.org/raid.htm" I thought if I run it to reconstruct that will help to recover more data and put the third drive to be Online but I am afraid that might erase the current data in the other drives. Please I need your advise in how I could retrive the remaining data? Thanks

    Read the article

  • Problems with 2 ISCSI connections esxi 3.5

    - by rphilli5
    I am running a dell poweredge 1950 with 4 nic cards. 1 is bonded to SAN #1 on 192.168.90.xx. The second SAN is on a separate network - 192.168.7.xx The network adapter can view the ip range of the san and the NIC can be pinged from 192.168.7.xx range. vswitch1 and vswitch2 are configured identically except for the ip address. The second SAN has been added to the iscsi software adapter but the SAN is never recognized. I can connect to the SAN from other machines on the local network. Is there something else that needs to be configured for the iscsi software adapter to know which vswitch to use?

    Read the article

  • Poor home office network performance and cannot figure out where the issue is

    - by Jeff Willener
    This is the most bizarre issue. I have worked with small to mid size networks for quite a long time and can say I'm comfortable connecting hardware. Where you will start to lose me is with managed switches and firewalls. To start, let me describe my network (sigh, shouldn't but I MUST solve this). 1) Comcast Cable Internet 2) Motorola SURFboard eXtreme Cable Modem. a) Model: SB6120 b) DOCSIS 3.0 and 2.0 support c) IPv4 and IPv6 support 3-A) Cisco Small Business RV220W Wireless N Firewall a) Latest firmware b) Model: RV220W-A-K9-NA c) WAN Port to Modem (2) d) vlan 1: work e) vlan 2: everything else. 3-B) D-Link DIR-615 Draft 802.11 N Wireless Router a) Latest firmware b) WAN Port to Modem (2) 4) Servers connected directly to firewall a) If firewall 3-A, then vlan 1 b) CAT5e patch cables c) Dell PowerEdge 1400SC w/ 10/100 integrated NIC (Domain Controller, DNS, former DHCP) d) Dell PowerEdge 400SC w/ 10/100/1000 integrated NIC (VMWare Server) 4) Linksys EZXS88W unmanaged Workgroup 10/100 Switch a) If firewall 3-A, then vlan 2 b) 25' CAT5e patch cable to firewall (3-A or 3-B) c) Connects xBox 360, Blu-Ray player, PC at TV 5) Office equipment connected directly to firewall a) If firewall 3-A, then vlan 1 b) ~80' CAT6 or CAT5e patch cable to firewall (3-A or 3-B) c) Connects 1) Dell Latitude laptop 10/100/1000 2) Dell Inspiron laptop 10/100 3) Dell Workstation 10/100/1000 (Pristine host, VMWare Workstation 7.x with many bridged VM's) 4) Brother Laser Printer 10/100 5) Epson All-In-One Workforce 310 10/100 5-A) NetGear FS116 unmanaged 10/100 switch a) I've had this switch for a long time and never had issues. 5-B) NetGear GS108 unmanaged 10/100/1000 switch a) Bought new for this issue and returned. 5-C) Linksys SE2500 unmanaged 10/100/1000 switch a) Bought new for this issue and returned. 5-D) TP-Link TL-SG10008D unmanaged 10/100/1000 a) Bought new for this issue and still have. 6) VLan 1 Wireless Connections (on same subnet if 3-B) a) Any of those at 5c b) HP Laptop 7) VLan 2 Wireless Connection (on same subnet if 3-B) a) IPad, IPod b) Compaq Laptop c) Epson Wireless Printer Shew, without hosting a diagram I hope that paints a good picture. The Issue The breakdown here is at item 5. No matter what I do I cannot have a switch at 5 and have to run everything wireless regardless of router. Issues related to using a switch (point 5 above) SpeedTest is good. Poor throughput to other devices if can communicate at all. Usually cannot ping other devices even on the same switch although, when able, ping times are good. Eventual lose of connectivity and can "sometimes" be restored by unplugging everything for several days, not minutes or hours but we're talking a week if at all. Directly connect to computer gives good internet connection however throughput to other devices connected to firewall is at best horrible. Yet printing doesn't seem to be an issue as long as they are connected via wireless. I have to force the RV220W to 1000Mb on the respective port if using a Gig Switch Issues related to using wireless in place of a switch (point 5 above) Poor throughput to other devices if can communicate. SpeedTest is good. Bottom line Internet speeds are awesome. By the way, Comcast went WAY above and beyond to make sure it was not them. They rewired EVERYTHING which did solve internet drops. Computer to computer connections are garbage Cannot get switch at 5 to work, yet other at 4 has never had an issue. Direct connection, bypass switch, is good for DHCP and internet. DNS must be on server, not firewall. Cisco insists its my switches but as you can see I have used four and two different cables with the same result. My gut feeling is something is happening with routing. But I'm not smart enough to know that answer. I run a lot of VM's at 5-c-3, could that cause it? What's different compared to my previous house is I have introduced Gigabit hardware (firewall/switches/computers). Some of my computers might have IPv6 turned on if I haven't turned it off already. I'm truly at a loss and hope anyone has some crazy idea how to solve this. Bottom line, I need a switch in my office behind the firewall. I've changed everything. The real crux is I will find a working solution and, again, after days it will stop working. So this means I cannot isolate if its a computer since I have to use them. Oh and a solution is not throwing more money at this. I'm well into $1k already. Yah, lame.

    Read the article

  • Dual Nic, one keeps dropping

    - by user1215018
    I'm running windows server 2008 r2 on a dell poweredge 2850. I have 2 NICs, one is configured behind a firewall with a dhcp server on the main local LAN and another one has it's own dedicated connection to one of our 13 static IPs. So in a nutshell we have 2 of our static IPs going to this server, one indirectly through a firewall/dhcp server, and the other directly. I am trying to reach IIS on port 80 and port 443. The problem is that the NIC with the direct connection (NIC2) keeps dropping and says either "No internet connection" or "Unauthenticated". However, the NIC behind the firewall (NIC1) has no problems at all. Update: This is the second time this has happened in 3 days and each time the fix has been enabling the dhcp client on the NIC, allowing it to error out to a 169.x.x.x address, then re-enabling the nic with it's static IP assignment.