Search Results

Search found 6100 results on 244 pages for 'power consumption'.

Page 46/244 | < Previous Page | 42 43 44 45 46 47 48 49 50 51 52 53  | Next Page >

  • LSI 9285-8e and Supermicro SC837E26-RJBOD1 duplicate enclosure ID and slot numbers

    - by Andy Shinn
    I am working with 2 x Supermicro SC837E26-RJBOD1 chassis connected to a single LSI 9285-8e card in a Supermicro 1U host. There are 28 drives in each chassis for a total of 56 drives in 28 RAID1 mirrors. The problem I am running in to is that there are duplicate slots for the 2 chassis (the slots list twice and only go from 0 to 27). All the drives also show the same enclosure ID (ID 36). However, MegaCLI -encinfo lists the 2 enclosures correctly (ID 36 and ID 65). My question is, why would this happen? Is there an option I am missing to use 2 enclosures effectively? This is blocking me rebuilding a drive that failed in slot 11 since I can only specify enclosure and slot as parameters to replace a drive. When I do this, it picks the wrong slot 11 (device ID 46 instead of device ID 19). Adapter #1 is the LSI 9285-8e, adapter #0 (which I removed due to space limitations) is the onboard LSI. Adapter information: Adapter #1 ============================================================================== Versions ================ Product Name : LSI MegaRAID SAS 9285-8e Serial No : SV12704804 FW Package Build: 23.1.1-0004 Mfg. Data ================ Mfg. Date : 06/30/11 Rework Date : 00/00/00 Revision No : 00A Battery FRU : N/A Image Versions in Flash: ================ BIOS Version : 5.25.00_4.11.05.00_0x05040000 WebBIOS Version : 6.1-20-e_20-Rel Preboot CLI Version: 05.01-04:#%00001 FW Version : 3.140.15-1320 NVDATA Version : 2.1106.03-0051 Boot Block Version : 2.04.00.00-0001 BOOT Version : 06.253.57.219 Pending Images in Flash ================ None PCI Info ================ Vendor Id : 1000 Device Id : 005b SubVendorId : 1000 SubDeviceId : 9285 Host Interface : PCIE ChipRevision : B0 Number of Frontend Port: 0 Device Interface : PCIE Number of Backend Port: 8 Port : Address 0 5003048000ee8e7f 1 5003048000ee8a7f 2 0000000000000000 3 0000000000000000 4 0000000000000000 5 0000000000000000 6 0000000000000000 7 0000000000000000 HW Configuration ================ SAS Address : 500605b0038f9210 BBU : Present Alarm : Present NVRAM : Present Serial Debugger : Present Memory : Present Flash : Present Memory Size : 1024MB TPM : Absent On board Expander: Absent Upgrade Key : Absent Temperature sensor for ROC : Present Temperature sensor for controller : Absent ROC temperature : 70 degree Celcius Settings ================ Current Time : 18:24:36 3/13, 2012 Predictive Fail Poll Interval : 300sec Interrupt Throttle Active Count : 16 Interrupt Throttle Completion : 50us Rebuild Rate : 30% PR Rate : 30% BGI Rate : 30% Check Consistency Rate : 30% Reconstruction Rate : 30% Cache Flush Interval : 4s Max Drives to Spinup at One Time : 2 Delay Among Spinup Groups : 12s Physical Drive Coercion Mode : Disabled Cluster Mode : Disabled Alarm : Enabled Auto Rebuild : Enabled Battery Warning : Enabled Ecc Bucket Size : 15 Ecc Bucket Leak Rate : 1440 Minutes Restore HotSpare on Insertion : Disabled Expose Enclosure Devices : Enabled Maintain PD Fail History : Enabled Host Request Reordering : Enabled Auto Detect BackPlane Enabled : SGPIO/i2c SEP Load Balance Mode : Auto Use FDE Only : No Security Key Assigned : No Security Key Failed : No Security Key Not Backedup : No Default LD PowerSave Policy : Controller Defined Maximum number of direct attached drives to spin up in 1 min : 10 Any Offline VD Cache Preserved : No Allow Boot with Preserved Cache : No Disable Online Controller Reset : No PFK in NVRAM : No Use disk activity for locate : No Capabilities ================ RAID Level Supported : RAID0, RAID1, RAID5, RAID6, RAID00, RAID10, RAID50, RAID60, PRL 11, PRL 11 with spanning, SRL 3 supported, PRL11-RLQ0 DDF layout with no span, PRL11-RLQ0 DDF layout with span Supported Drives : SAS, SATA Allowed Mixing: Mix in Enclosure Allowed Mix of SAS/SATA of HDD type in VD Allowed Status ================ ECC Bucket Count : 0 Limitations ================ Max Arms Per VD : 32 Max Spans Per VD : 8 Max Arrays : 128 Max Number of VDs : 64 Max Parallel Commands : 1008 Max SGE Count : 60 Max Data Transfer Size : 8192 sectors Max Strips PerIO : 42 Max LD per array : 16 Min Strip Size : 8 KB Max Strip Size : 1.0 MB Max Configurable CacheCade Size: 0 GB Current Size of CacheCade : 0 GB Current Size of FW Cache : 887 MB Device Present ================ Virtual Drives : 28 Degraded : 0 Offline : 0 Physical Devices : 59 Disks : 56 Critical Disks : 0 Failed Disks : 0 Supported Adapter Operations ================ Rebuild Rate : Yes CC Rate : Yes BGI Rate : Yes Reconstruct Rate : Yes Patrol Read Rate : Yes Alarm Control : Yes Cluster Support : No BBU : No Spanning : Yes Dedicated Hot Spare : Yes Revertible Hot Spares : Yes Foreign Config Import : Yes Self Diagnostic : Yes Allow Mixed Redundancy on Array : No Global Hot Spares : Yes Deny SCSI Passthrough : No Deny SMP Passthrough : No Deny STP Passthrough : No Support Security : No Snapshot Enabled : No Support the OCE without adding drives : Yes Support PFK : Yes Support PI : No Support Boot Time PFK Change : Yes Disable Online PFK Change : No PFK TrailTime Remaining : 0 days 0 hours Support Shield State : Yes Block SSD Write Disk Cache Change: Yes Supported VD Operations ================ Read Policy : Yes Write Policy : Yes IO Policy : Yes Access Policy : Yes Disk Cache Policy : Yes Reconstruction : Yes Deny Locate : No Deny CC : No Allow Ctrl Encryption: No Enable LDBBM : No Support Breakmirror : No Power Savings : Yes Supported PD Operations ================ Force Online : Yes Force Offline : Yes Force Rebuild : Yes Deny Force Failed : No Deny Force Good/Bad : No Deny Missing Replace : No Deny Clear : No Deny Locate : No Support Temperature : Yes Disable Copyback : No Enable JBOD : No Enable Copyback on SMART : No Enable Copyback to SSD on SMART Error : Yes Enable SSD Patrol Read : No PR Correct Unconfigured Areas : Yes Enable Spin Down of UnConfigured Drives : Yes Disable Spin Down of hot spares : No Spin Down time : 30 T10 Power State : Yes Error Counters ================ Memory Correctable Errors : 0 Memory Uncorrectable Errors : 0 Cluster Information ================ Cluster Permitted : No Cluster Active : No Default Settings ================ Phy Polarity : 0 Phy PolaritySplit : 0 Background Rate : 30 Strip Size : 64kB Flush Time : 4 seconds Write Policy : WB Read Policy : Adaptive Cache When BBU Bad : Disabled Cached IO : No SMART Mode : Mode 6 Alarm Disable : Yes Coercion Mode : None ZCR Config : Unknown Dirty LED Shows Drive Activity : No BIOS Continue on Error : No Spin Down Mode : None Allowed Device Type : SAS/SATA Mix Allow Mix in Enclosure : Yes Allow HDD SAS/SATA Mix in VD : Yes Allow SSD SAS/SATA Mix in VD : No Allow HDD/SSD Mix in VD : No Allow SATA in Cluster : No Max Chained Enclosures : 16 Disable Ctrl-R : Yes Enable Web BIOS : Yes Direct PD Mapping : No BIOS Enumerate VDs : Yes Restore Hot Spare on Insertion : No Expose Enclosure Devices : Yes Maintain PD Fail History : Yes Disable Puncturing : No Zero Based Enclosure Enumeration : No PreBoot CLI Enabled : Yes LED Show Drive Activity : Yes Cluster Disable : Yes SAS Disable : No Auto Detect BackPlane Enable : SGPIO/i2c SEP Use FDE Only : No Enable Led Header : No Delay during POST : 0 EnableCrashDump : No Disable Online Controller Reset : No EnableLDBBM : No Un-Certified Hard Disk Drives : Allow Treat Single span R1E as R10 : No Max LD per array : 16 Power Saving option : Don't Auto spin down Configured Drives Max power savings option is not allowed for LDs. Only T10 power conditions are to be used. Default spin down time in minutes: 30 Enable JBOD : No TTY Log In Flash : No Auto Enhanced Import : No BreakMirror RAID Support : No Disable Join Mirror : No Enable Shield State : Yes Time taken to detect CME : 60s Exit Code: 0x00 Enclosure information: # /opt/MegaRAID/MegaCli/MegaCli64 -encinfo -a1 Number of enclosures on adapter 1 -- 3 Enclosure 0: Device ID : 36 Number of Slots : 28 Number of Power Supplies : 2 Number of Fans : 3 Number of Temperature Sensors : 1 Number of Alarms : 1 Number of SIM Modules : 0 Number of Physical Drives : 28 Status : Normal Position : 1 Connector Name : Port B Enclosure type : SES VendorId is LSI CORP and Product Id is SAS2X36 VendorID and Product ID didnt match FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : 65 Inquiry data : Vendor Identification : LSI CORP Product Identification : SAS2X36 Product Revision Level : 0718 Vendor Specific : x36-55.7.24.1 Number of Voltage Sensors :2 Voltage Sensor :0 Voltage Sensor Status :OK Voltage Value :5020 milli volts Voltage Sensor :1 Voltage Sensor Status :OK Voltage Value :11820 milli volts Number of Power Supplies : 2 Power Supply : 0 Power Supply Status : OK Power Supply : 1 Power Supply Status : OK Number of Fans : 3 Fan : 0 Fan Speed :Low Speed Fan Status : OK Fan : 1 Fan Speed :Low Speed Fan Status : OK Fan : 2 Fan Speed :Low Speed Fan Status : OK Number of Temperature Sensors : 1 Temp Sensor : 0 Temperature : 48 Temperature Sensor Status : OK Number of Chassis : 1 Chassis : 0 Chassis Status : OK Enclosure 1: Device ID : 65 Number of Slots : 28 Number of Power Supplies : 2 Number of Fans : 3 Number of Temperature Sensors : 1 Number of Alarms : 1 Number of SIM Modules : 0 Number of Physical Drives : 28 Status : Normal Position : 1 Connector Name : Port A Enclosure type : SES VendorId is LSI CORP and Product Id is SAS2X36 VendorID and Product ID didnt match FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : 36 Inquiry data : Vendor Identification : LSI CORP Product Identification : SAS2X36 Product Revision Level : 0718 Vendor Specific : x36-55.7.24.1 Number of Voltage Sensors :2 Voltage Sensor :0 Voltage Sensor Status :OK Voltage Value :5020 milli volts Voltage Sensor :1 Voltage Sensor Status :OK Voltage Value :11760 milli volts Number of Power Supplies : 2 Power Supply : 0 Power Supply Status : OK Power Supply : 1 Power Supply Status : OK Number of Fans : 3 Fan : 0 Fan Speed :Low Speed Fan Status : OK Fan : 1 Fan Speed :Low Speed Fan Status : OK Fan : 2 Fan Speed :Low Speed Fan Status : OK Number of Temperature Sensors : 1 Temp Sensor : 0 Temperature : 47 Temperature Sensor Status : OK Number of Chassis : 1 Chassis : 0 Chassis Status : OK Enclosure 2: Device ID : 252 Number of Slots : 8 Number of Power Supplies : 0 Number of Fans : 0 Number of Temperature Sensors : 0 Number of Alarms : 0 Number of SIM Modules : 1 Number of Physical Drives : 0 Status : Normal Position : 1 Connector Name : Unavailable Enclosure type : SGPIO Failed in first Inquiry commnad FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : Unavailable Inquiry data : Vendor Identification : LSI Product Identification : SGPIO Product Revision Level : N/A Vendor Specific : Exit Code: 0x00 Now, notice that each slot 11 device shows an enclosure ID of 36, I think this is where the discrepancy happens. One should be 36. But the other should be on enclosure 65. Drives in slot 11: Enclosure Device ID: 36 Slot Number: 11 Drive's postion: DiskGroup: 5, Span: 0, Arm: 1 Enclosure position: 0 Device Id: 48 WWN: Sequence Number: 11 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SATA Raw Size: 2.728 TB [0x15d50a3b0 Sectors] Non Coerced Size: 2.728 TB [0x15d40a3b0 Sectors] Coerced Size: 2.728 TB [0x15d400000 Sectors] Firmware state: Online, Spun Up Is Commissioned Spare : YES Device Firmware Level: A5C0 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5003048000ee8a53 Connected Port Number: 1(path0) Inquiry Data: MJ1311YNG6YYXAHitachi HDS5C3030ALA630 MEAOA5C0 FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :30C (86.00 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Drive's write cache : Disabled Drive's NCQ setting : Enabled Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No Enclosure Device ID: 36 Slot Number: 11 Drive's postion: DiskGroup: 19, Span: 0, Arm: 1 Enclosure position: 0 Device Id: 19 WWN: Sequence Number: 4 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SATA Raw Size: 2.728 TB [0x15d50a3b0 Sectors] Non Coerced Size: 2.728 TB [0x15d40a3b0 Sectors] Coerced Size: 2.728 TB [0x15d400000 Sectors] Firmware state: Online, Spun Up Is Commissioned Spare : NO Device Firmware Level: A580 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5003048000ee8e53 Connected Port Number: 0(path0) Inquiry Data: MJ1313YNG1VA5CHitachi HDS5C3030ALA630 MEAOA580 FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :30C (86.00 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Drive's write cache : Disabled Drive's NCQ setting : Enabled Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No Update 06/28/12: I finally have some new information about (what we think) the root cause of this problem so I thought I would share. After getting in contact with a very knowledgeable Supermicro tech, they provided us with a tool called Xflash (doesn't appear to be readily available on their FTP). When we gathered some information using this utility, my colleague found something very strange: root@mogile2 test]# ./xflash.dat -i get avail Initializing Interface. Expander: SAS2X36 (SAS2x36) 1) SAS2X36 (SAS2x36) (50030480:00EE917F) (0.0.0.0) 2) SAS2X36 (SAS2x36) (50030480:00E9D67F) (0.0.0.0) 3) SAS2X36 (SAS2x36) (50030480:0112D97F) (0.0.0.0) This lists the connected enclosures. You see the 3 connected (we have since added a 3rd and a 4th which is not yet showing up) with their respective SAS address / WWN (50030480:00EE917F). Now we can use this address to get information on the individual enclosures: [root@mogile2 test]# ./xflash.dat -i 5003048000EE917F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:00EE917F Enclosure Logical Id: 50030480:0000007F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 [root@mogile2 test]# ./xflash.dat -i 5003048000E9D67F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:00E9D67F Enclosure Logical Id: 50030480:0000007F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 [root@mogile2 test]# ./xflash.dat -i 500304800112D97F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:0112D97F Enclosure Logical Id: 50030480:0112D97F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 Did you catch it? The first 2 enclosures logical ID is partially masked out where the 3rd one (which has a correct unique enclosure ID) is not. We pointed this out to Supermicro and were able to confirm that this address is supposed to be set during manufacturing and there was a problem with a certain batch of these enclosures where the logical ID was not set. We believe that the RAID controller is determining the ID based on the logical ID and since our first 2 enclosures have the same logical ID, they get the same enclosure ID. We also confirmed that 0000007F is the default which comes from LSI as an ID. The next pointer that helps confirm this could be a manufacturing problem with a run of JBODs is the fact that all 6 of the enclosures that have this problem begin with 00E. I believe that between 00E8 and 00EE Supermicro forgot to program the logical IDs correctly and neglected to recall or fix the problem post production. Fortunately for us, there is a tool to manage the WWN and logical ID of the devices from Supermicro: ftp://ftp.supermicro.com/utility/ExpanderXtools_Lite/. Our next step is to schedule a shutdown of these JBODs (after data migration) and reprogram the logical ID and see if it solves the problem. Update 06/28/12 #2: I just discovered this FAQ at Supermicro while Google searching for "lsi 0000007f": http://www.supermicro.com/support/faqs/faq.cfm?faq=11805. I still don't understand why, in the last several times we contacted Supermicro, they would have never directed us to this article :\

    Read the article

  • Can't Get Mac Mini to turn on - no screen, no beep, only the fan, power light, and optical drive noi

    - by pibyers
    I have an Intel-based Mac mini mid-2007 (Model A1176). This is the computer my kids use so I don't use it regularly. The computer had been working fine until one day my kids told me that it no longer works. The computer will not boot up. When I turn it on the fan turns, the white power light in the front turns on, and there is a sound that appears to be from the optical drive (rather than hard drive). I don't get anything to the monitor, nor do I get any dings or other start up sounds from the computer. Here is what I've tried thus far to no avail: 1) Swapped out the monitors early on since I figured that was my weak link - no change 2) Reset the PMU - no change 3) Tried to boot up from the System Disk - The mini loaded the dvd into the drive, but nothing else (I can't eject the disk so I can put it back) 3) Start up the computer in target mode connected to another mac - I tried this too, but I never received a chime or the disk show up on the other mac. I'm about out of ideas apart from scraping the computer. Does anyone have any ideas that I can try? Again, nothing has been done to the computer in at least 6 months when I upgraded the RAM. I'm also still on Leopard. Thanks.

    Read the article

  • Garbage Collector not doing its job. Memory Consumption = 1.5GB & OutOFMemory Exception.

    - by imageWorker
    I'm working with images (each of size = 5MB). The following code extract some information from each image that is present in the given directory. I'm getting out of memory exception. The size of the process is around (1.5GB). I don't know why garbage collector is not freeing memory. I even tried adding GC.Collect() as last line of foreach loop. Still I'm getting 'OutOFMemory' using System; using System.Collections.Generic; using System.Linq; using System.Text; using System.Threading; using System.IO; using System.Drawing; using System.Drawing.Imaging; namespace TrainSVM { class Program { static void Main(string[] args) { FileStream fs = new FileStream("dg.train",FileMode.OpenOrCreate,FileAccess.Write); StreamWriter sw = new StreamWriter(fs); String[] filePathArr = Directory.GetFiles("E:\\images\\"); foreach (string filePath in filePathArr) { if (filePath.Contains("lmn")) { sw.Write("1 "); Console.Write("1 "); } else { sw.Write("1 "); Console.Write("1 "); } Bitmap originalBMP = new Bitmap(filePath); /***********************/ Bitmap imageBody; ImageBody.ImageBody im = new ImageBody.ImageBody(originalBMP); imageBody = im.GetImageBody(-1); /* white coat */ Bitmap whiteCoatBitmap = Rgb2Hsi.Rgb2Hsi.GetHuePlane(imageBody); float WhiteCoatPixelPercentage = Rgb2Hsi.Rgb2Hsi.GetWhiteCoatPixelPercentage(whiteCoatBitmap); //Console.Write("whiteDone\t"); sw.Write("1:" + WhiteCoatPixelPercentage + " "); Console.Write("1:" + WhiteCoatPixelPercentage + " "); /******************/ Quaternion.Quaternion qtr = new Quaternion.Quaternion(-15); Bitmap yellowCoatBMP = qtr.processImage(imageBody); //yellowCoatBMP.Save("yellowCoat.bmp"); float yellowCoatPixelPercentage = qtr.GetYellowCoatPixelPercentage(yellowCoatBMP); //Console.Write("yellowCoatDone\t"); sw.Write("2:" + yellowCoatPixelPercentage + " "); Console.Write("2:" + yellowCoatPixelPercentage + " "); /**********************/ Bitmap balckPatchBitmap = BlackPatchDetection.BlackPatchDetector.MarkBlackPatches(imageBody); float BlackPatchPixelPercentage = BlackPatchDetection.BlackPatchDetector.BlackPatchPercentage; //Console.Write("balckPatchDone\n"); sw.Write("3:" + BlackPatchPixelPercentage + "\n"); Console.Write("3:" + BlackPatchPixelPercentage + "\n"); balckPatchBitmap.Dispose(); yellowCoatBMP.Dispose(); whiteCoatBitmap.Dispose(); originalBMP.Dispose(); sw.Flush(); } sw.Dispose(); fs.Dispose(); } } }

    Read the article

  • What can I do to prevent system power downs?

    - by Joe King
    Yesterday I was given my brother's old laptop - core i7, 2.67GHz, 8GB RAM, 128GB SSD, Win7 64 bit. It's a Sony Vaio Z11. Approx 18 months old. When running something computationally intensive, the fan starts up and after about 30 secs it just powers itself down with no warning. I guess it is overheating. There is nothing in the event logs to suggest what is causing it - the only thing I see is "the last system shutdown was unexpected" or something similar. This is a problem for me because I use a lot of number crunching apps, which pretty much makes it useless to me. I would like to know if there is anything I can do, other than the obvious things I've done already - open up and clean out dust, re-install the OS. According to my brother, this problem started about 6 months ago when it was already outside warranty. If it's just used for simple things - web browsing, word processing etc, the problem does not occur. Any ideas for what I can do to fix this ? Update: I found that the laptop has 2 hardware settings for graphics: Speed and Stamina - the Speed setting seems to use an nvidia GEforce GT 330M, while the Stamina setting uses an Intel chipset. With the setting on Speed, I can hear the fan the whole time, and the system powers down after a short while (5-10 mins) even just doing basic tasks (browsing this site for example), but doesn't shut down if I just leave it switched on. In this mode it also sometimes just freezes the screen and I have to power off myself. However on Stamina setting it only powers down when doing number crunching and never freezes the screen.

    Read the article

  • Is there a way to force the monitor to power off in Windows 8?

    - by Rune Jacobsen
    I have googled this a bit and looked at powrprof.dll and PsShutdown but I haven't found a way to do exactly what I want to do. You know that power save option that lets Windows turn off your monitor(s) if you haven't touched the system for x amount of time? Well, I have a PC that needs to be on most of the day (and night), and I have to watch it much of the time, so I can't have a short timeout for automatically turning off the monitor. However, once I leave it for a few hours (happens at varying times of the day), I would like to be able to issue a command that puts the computer in this mode. Not sleep mode, not hibernate mode. Monitor off, that is all. I realize of course I could just turn the physical monitor off. That is not what I want. This Dell monitor takes forever to display a picture from a cold state. If it is turned off by the computer not sending a signal - not so bad. Is there any way for me to do this? As mentioned, the OS can do it, so I would find it really useful if I could do it too. :)

    Read the article

  • Pull network or power? (for contianing a rooted server)

    - by Aleksandr Levchuk
    When a server gets rooted (e.g. a situation like this), one of the first things that you may decide to do is containment. Some security specialists advise not to enter remediation immediately and to keep the server online until forensics are completed. Those advises are usually for APT. It's different if you have occasional Script kiddie breaches. However, you may decide to remediate (fix things) early and one of the steps in remediation is containment of the server. Quoting from Robert Moir's Answer - "disconnect the victim from its muggers". A server can be contained by pulling the network cable or the power cable. Which method is better? Taking into consideration the need for: Protecting victims from further damage Executing successful forensics (Possibly) Protecting valuable data on the server Edit: 5 assumptions Assuming: You detected early: 24 hours. You want to recover early: 3 days of 1 systems admin on the job (forensics and recovery). The server is not a Virtual Machine or a Container able to take a snapshot capturing the contents of the servers memory. You decide not to attempt prosecuting. You suspect that the attacker may be using some form of software (possibly sophisticated) and this software is still running on the server.

    Read the article

  • Link failure with either abnormal memory consumption or LNK1106 in Visual Studio 2005.

    - by Corvin
    Hello, I am trying to build a solution for windows XP in Visual Studio 2005. This solution contains 81 projects (static libs, exe's, dlls) and is being successfully used by our partners. I copied the solution bundle from their repository and tried setting it up on 3 similar machines of people in our group. I was successful on two machines and the solution failed to build on my machine. The build on my machine encountered two problems: During a simple build creation of the biggest static library (about 522Mb in debug mode) would fail with the message "13libd\ui1d.lib : fatal error LNK1106: invalid file or disk full: cannot seek to 0x20101879" Full solution rebuild creates this library, however when it comes to linking the library to main .exe file, devenv.exe spawns link.exe which consumes about 80Mb of physical memory and 250MB of virtual and spawns another link.exe, which does the same. This goes on until the system runs out of memory. On PCs of my colleagues where successful build could be performed, there is only one link.exe process which uses all the memory required for linking (about 500Mb physical). There is a plenty of hard drive space on my machine and the file system is NTFS. All three of our systems are similar - Core2Quad processors, 4Gb of RAM, Windows XP SP3. We are using Visual studio installed from the same source. I tried using a different RAM and CPU, using dedicated graphics adapter to eliminate possibility of video memory sharing influencing the build, putting solution files to different location, using different versions of VS 2005 (Professional, Standard and Team Suite), changing the amount of available virtual memory, running memtest86 and building the project from scratch (i.e. a clean bundle). I have read what MSDN says about LNK1106, none of the cases apply to me except for maybe "out of heap space", however I am not sure how I should fight this. The only idea that I have left is reinstalling the OS, however I am not sure that it would help and I am not sure that my situation wouldn't repeat itself on a different machine. Would anyone have any sort of advice for me? Thanks

    Read the article

  • Running two graphics cards (non-SLI) to power 3D on two different monitors?

    - by Delameko
    Hi, I'm a bit clueless about this, so excuse my naivety. I have two video cards, a Nvidia 8800 and a GT120, powering three monitors. I run two 3D game instances (two Everquest 2 clients), one on each of my first two monitors. It's been running fine, although sometimes it sounds like the computer is trying to take off. Today I realised that I was actually playing them on the two monitors that are both powered by the 8800. Thinking that I might as well make use of the power of both cards I tried switching the monitor cables over so that each card would be "powering" one of the clients. (Is it silly to assume this is how it works?) This doesn't seem to have had the desired effect, as the client running on the 8800 screen is running worse than it was before. Is it even possible to run two clients on separate GPUs? Is SLI the only way to utilise 2 GPUs? Is there something special I have to do? Or do I have to set the client to use a particular GPU (an option I can't seem to find in EQ2)? I run the clients in window mode if that makes any difference, and I'm running Win 7. Thanks.

    Read the article

  • How do you protect yourself from runaway memory consumption bringing down the PC?

    - by romkyns
    Every now and again I find myself doing something moderately dumb that results in my program allocating all the memory it can get and then some. This kind of thing used to cause the program to die fairly quickly with an "out of memory" error, but these days Windows will go out of its way to give this non-existent memory to the application, and in fact is apparently prepared to commit suicide doing so. Not literally of course, but it will starve itself of usable physical RAM so badly that even running the task manager will require half an hour of swapping (after all the runaway application is still allocating more and more memory all the time). This doesn't happen too often, but when it does it's disastrous. I usually have to reset my machine, causing data loss from time to time and generally a lot of inconvenience. Do you have any practical advice on making the consequences of such a mistake less dire? Perhaps some registry tweak to limit the max amount of virtual memory an app is allowed to allocate? Or some CLR flag that will limit this only for the current application? (It's usually in .NET that I do this to myself.) ("Don't run out of RAM" and "Buy more RAM" are no use - the former I have no control over, and the latter I've already done.)

    Read the article

  • How to generate and encode (for use in GA), random, strict, binary rooted trees with N leaves?

    - by Peter Simon
    First, I am an engineer, not a computer scientist, so I apologize in advance for any misuse of nomenclature and general ignorance of CS background. Here is the motivational background for my question: I am contemplating writing a genetic algorithm optimizer to aid in designing a power divider network (also called a beam forming network, or BFN for short). The BFN is intended to distribute power to each of N radiating elements in an array of antennas. The fraction of the total input power to be delivered to each radiating element has been specified. Topologically speaking, a BFN is a strictly binary, rooted tree. Each of the (N-1) interior nodes of the tree represents the input port of an unequal, binary power splitter. The N leaves of the tree are the power divider outputs. Given a particular power divider topology, one is still free to map the power divider outputs to the array inputs in an arbitrary order. There are N! such permutations of the outputs. There are several considerations in choosing the desired ordering: 1) The power ratio for each binary coupler should be within a specified range of values. 2) The ordering should be chosen to simplify the mechanical routing of the transmission lines connecting the power divider. The number of ouputs N of the BFN may range from, say, 6 to 22. I have already written a genetic algorithm optimizer that, given a particular BFN topology and desired array input power distribution, will search through the N! permutations of the BFN outputs to generate a design with compliant power ratios and good mechanical routing. I would now like to generalize my program to automatically generate and search through the space of possible BFN topologies. As I understand it, for N outputs (leaves of the binary tree), there are $C_{N-1}$ different topologies that can be constructed, where $C_N$ is the Catalan number. I would like to know how to encode an arbitrary tree having N leaves in a way that is consistent with a chromosomal description for use in a genetic algorithm. Also associated with this is the need to generate random instances for filling the initial population, and to implement crossover and mutations operators for this type of chromosome. Any suggestions will be welcome. Please minimize the amount of CS lingo in your reply, since I am not likely to be acquainted with it. Thanks in advance, Peter

    Read the article

  • Laptop battery holds charge, but won't charge any more.

    - by Jeff
    Ok, I'm sure I will need to replace either my battery or my AC adapter, but would rather not buy one if the other is the problem. My problem is. I have a Sager laptop that gets quite a bit of use. The charging has always been a little bit odd. If I was in the process of using it, it would charge just fine and stay On AC power. If I left it alone, however(power settings to ONLY turn off the monitor) in either Ubuntu or Windows 7 it decides that it didn't want to use AC power anymore and would just start draining the battery until it died. Now, suddenly, it won't charge at all. The capacity was great up to this point which happened in an instant. It will recognize the battery but won't see the AC power if plugged in while the battery is in. I can power up the laptop without the battery and it works fine. If I plug in the battery while powered up it will claim it's charging it, but it stays at the same percentage. If I unplug the power, it will switch over to Battery fine, but I have to power down and unplug the battery to get it back on AC power. I've had dying/dead batteries before but they typically won't hold a full charge anymore but it still winds up to 100% then drops quickly when unplugged. This seems more like a chip problem in the battery to me, but I'm not sure. Any ideas?

    Read the article

  • How to add dynamic profile fields in Invision Power Board?

    - by user361908
    I run a game server and want to link the persons in game character name and stats to Invision Power Board. I've setup IPB so players currently login with their in game login. That means their username on the forum is the same as their username for the game. They can have multiple characters on 1 account so ideally I'd like to allow them to choose a main character and display an actual image of that character and allow them to display other characters if they are online. Currently I'm doing something like this by hacking profileFields.php but it's messy and not very efficient on the user or server end. My code currently uses 2 custom fields which the player can enter their character names in. To display only their main character they enter the name in the first field. To also display other characters if they are online they enter the same name into the second field. To resolve the IDs I have to run a lot of queries. I know PHP but I am not familiar with IPBs code at all. I just need pointed in a direction where I can combine the 2 fields into 1 field. tl;dr: Here is my setup: Invision Power Board 3 Data is stored in MySQL on the same server the forum is hosted on. Usernames on the forum are identical to usernames in the game Here is a breakdown of what I'd like to do: In the edit profile section I need to resolve the forum username to the games account id then: Display a list of characters and allow them to choose which characters they want to display if they are online as well as a default character that will be displayed if none are online. In the posts user info pane: Display the online character or the default if none are online. Here is what I need to know: How to generate a list of characters in the profile edit form and allow selection (checkbox) of each character to display as well as the selection of a default character (radio or dropdown?) How to fetch the data and place it in the posts user info pane

    Read the article

  • What part of SMF is likely broken by a hard power down?

    - by David Mackintosh
    At one of my customer sites, the local guy shut down their local Solaris 10 x86 server, pulled the power inputs, moved it, and now it won’t start properly. It boots and then presents a prompt which lets you log in. This appears to be single user milestone (or equivalent). Digging into it, I think that SMF isn’t permitting the system to go multi-user. SMF was generating a ton of errors on autofs, after some fooling with it I got it to generate errors on inetd and nfs/client instead. This all tells me that the problem is in some SMF state file or database that needs to be fixed/deleted/recreated or something, but I don’t know what the actual issue is. By “generate errors”, I mean that every second I get a message on the console saying “Method or service exit timed out. Killing contract <#.” This makes interacting with the computer difficult. Running svcs –xv shows the service as “enabled”, in state “disabled”, reason “Start method is running”. Fooling with svcadm on the service does nothing, except confirm that the service is not in a Maintenance state. Logs in /lib/svc/log/$SERVICE just tell you that this loop has been happening once per second. Logs in /etc/svc/volatile/$SERVICE confirm that at boot the service is attempted to start, and immediately stopped, no further entries. Note that system-log isn’t starting because system-log depends on autofs so I have no syslog or dmesg. Googling all these terms ends up telling me how to debug/fix either autofs or nfs/client or inetd or rpc/gss (which was the dependency that SMF was using as an excuse to prevent nfs/client from “starting”, it was claiming that rpc/gss was “undefined” which is incorrect since this all used to work. I re-enabled it with inetadm, but inetd still won’t start properly). But I think that the problem is SMF in general, not the individual services. Doing a restore_repository to the “manifest_import” does nothing to improve, or even detectibly change, the situation. I didn’t use a boot backup because the last boot(s) were not useful. I have told the customer that since the valuable data directories are on a separate file system (which fsck’s as clean so it is intact) we could just re-install solaris 10 on the / partition. But that seems like an awfully windows-like solution to inflict on this problem. So. Any ideas what piece is broken and how I might fix it?

    Read the article

  • Raid 1 array won't assemble after power outage. How do I fix this ext4 mirror?

    - by Forkrul Assail
    Two ext4 drives on Raid 1 with mdadm won't reassemble after the power went out for an extended period (UPS drained). After turning the machine back on, mdadm said that the array was degraded, after which it took about 2 days for a full resync, which completed without problems. On trying to remount the array I get: mount: you must specify the filesystem type cat /etc/fstab lines relevant to setup: /dev/md127 /media/mediapool ext4 defaults 0 0 dmesg | tail (on trying to mount) says: [ 1050.818782] EXT3-fs (md127): error: can't find ext3 filesystem on dev md127. [ 1050.849214] EXT4-fs (md127): VFS: Can't find ext4 filesystem [ 1050.944781] FAT-fs (md127): invalid media value (0x00) [ 1050.944782] FAT-fs (md127): Can't find a valid FAT filesystem [ 1058.272787] EXT2-fs (md127): error: can't find an ext2 filesystem on dev md127. cat /proc/mdstat says: Personalities : [raid1] [linear] [multipath] [raid0] [raid6] [raid5] [raid4] [raid10] md127 : active (auto-read-only) raid1 sdj[2] sdi[0] 2930135360 blocks super 1.2 [2/2] [UU] unused devices: <none> fsck /dev/md127 says: fsck from util-linux 2.20.1 e2fsck 1.42 (29-Nov-2011) fsck.ext2: Superblock invalid, trying backup blocks... fsck.ext2: Bad magic number in super-block while trying to open /dev/md127 The superblock could not be read or does not describe a correct ext2 filesystem. If the device is valid and it really contains an ext2 filesystem (and not swap or ufs or something else), then the superblock is corrupt, and you might try running e2fsck with an alternate superblock: e2fsck -b 8193 <device> mdadm -E /dev/sdi gives me: /dev/sdi: Magic : a92b4efc Version : 1.2 Feature Map : 0x0 Array UUID : 37ac1824:eb8a21f6:bd5afd6d:96da6394 Name : sojourn:33 Creation Time : Sat Nov 10 10:43:52 2012 Raid Level : raid1 Raid Devices : 2 Avail Dev Size : 5860271016 (2794.40 GiB 3000.46 GB) Array Size : 2930135360 (2794.39 GiB 3000.46 GB) Used Dev Size : 5860270720 (2794.39 GiB 3000.46 GB) Data Offset : 262144 sectors Super Offset : 8 sectors State : clean Device UUID : 3e6e9a4f:6c07ab3d:22d47fce:13cecfd0 Update Time : Tue Nov 13 20:34:18 2012 Checksum : f7d10db9 - correct Events : 27 Device Role : Active device 0 Array State : AA ('A' == active, '.' == missing) boot@boot ~ $ sudo mdadm -E /dev/sdj /dev/sdj: Magic : a92b4efc Version : 1.2 Feature Map : 0x0 Array UUID : 37ac1824:eb8a21f6:bd5afd6d:96da6394 Name : sojourn:33 Creation Time : Sat Nov 10 10:43:52 2012 Raid Level : raid1 Raid Devices : 2 Avail Dev Size : 5860271016 (2794.40 GiB 3000.46 GB) Array Size : 2930135360 (2794.39 GiB 3000.46 GB) Used Dev Size : 5860270720 (2794.39 GiB 3000.46 GB) Data Offset : 262144 sectors Super Offset : 8 sectors State : clean Device UUID : 7fb84af4:e9295f7b:ede61f27:bec0cb57 Update Time : Tue Nov 13 20:34:18 2012 Checksum : b9d17fef - correct Events : 27 Device Role : Active device 1 Array State : AA ('A' == active, '.' == missing) machine@user ~ dmesg | tail [ 61.785866] init: alsa-restore main process (2736) terminated with status 99 [ 68.433548] eth0: no IPv6 routers present [ 534.142511] EXT4-fs (sdi): ext4_check_descriptors: Block bitmap for group 0 not in group (block 2838187772)! [ 534.142518] EXT4-fs (sdi): group descriptors corrupted! [ 546.418780] EXT2-fs (sdi): error: couldn't mount because of unsupported optional features (240) [ 549.654127] EXT3-fs (sdi): error: couldn't mount because of unsupported optional features (240) Since this is Raid 1 it was suggested that I try and mount or fsck the drives separately. After a long fsck on one drive, it ended with this as tail: Illegal double indirect block (2298566437) in inode 39717736. CLEARED. Illegal block #4231180 (2611866932) in inode 39717736. CLEARED. Error storing directory block information (inode=39717736, block=0, num=1092368): Memory allocation failed Recreate journal? yes Creating journal (32768 blocks): Done. *** journal has been re-created - filesystem is now ext3 again *** The drive however still doesn't want to mount: dmesg | tail [ 170.674659] md: export_rdev(sdc) [ 170.675152] md: export_rdev(sdc) [ 195.275288] md: export_rdev(sdc) [ 195.275876] md: export_rdev(sdc) [ 1338.540092] CE: hpet increased min_delta_ns to 30169 nsec [26125.734105] EXT4-fs (sdc): ext4_check_descriptors: Checksum for group 0 failed (43502!=37987) [26125.734115] EXT4-fs (sdc): group descriptors corrupted! [26182.325371] EXT3-fs (sdc): error: couldn't mount because of unsupported optional features (240) [27083.316519] EXT4-fs (sdc): ext4_check_descriptors: Checksum for group 0 failed (43502!=37987) [27083.316530] EXT4-fs (sdc): group descriptors corrupted! Please help me fix this. I never in my wildest nightmares thought a complete mirror would die this badly. Am I missing something? Suggestions on fixing this? Could someone explain why it would resync after the powerout, only to seemingly nuke the drive? Thanks for reading. Any help much appreciated. I've tried everything I can think of, including booting and filesystem checking with SystemRescue and Ubuntu liveboot discs.

    Read the article

  • Trying to prevent Windows from hibernating/sleeping automatically

    - by user328821
    My Dell XPS 8700 (Win 7) suddenly began putting itself to sleep at 6pm daily, even if I'm typing. I don't know what caused this to occur, except possibly a windows update that took place in the middle of the night. I initially went into settings for power and saw 2 plans set up, one from Dell and the other window's Power saver plan. I set both to never for sleep and hibernate yet it still occurred. I have current drivers and a fairly new UPS that has software to set to shutdown only after power loss. Dell is of little help, can anyone point me in the right direction? I did do the powerdfg -energy program and came up with this: Power Efficiency Diagnostics Report Scan Time 2014-05-08T19:21:48Z Scan Duration 60 seconds System Manufacturer Dell Inc. System Product Name XPS 8700 BIOS Date 08/23/2013 BIOS Version A04 OS Build 7601 Platform Role PlatformRoleDesktop Plugged In true Process Count 115 Thread Count 1631 Report GUID {097caf99-039b-44c3-b154-d797bfbfdfcc} Analysis Results Errors Power Policy:Sleep timeout is disabled (Plugged In) The computer is not configured to automatically sleep after a period of inactivity. System Availability Requests:System Required Request The device or driver has made a request to prevent the system from automatically entering sleep. Requesting Driver Instance HDAUDIO\FUNC_01&VEN_10EC&DEV_0899&SUBSYS_102805B7&REV_1000\4&220b1bbc&0&0001 Requesting Driver Device Realtek High Definition Audio CPU Utilization:Processor utilization is high The average processor utilization during the trace was high. The system will consume less power when the average processor utilization is very low. Review processor utilization for individual processes to determine which applications and services contribute the most to total processor utilization. Average Utilization (%) 9.48 Warnings Platform Timer Resolution:Platform Timer Resolution The default platform timer resolution is 15.6ms (15625000ns) and should be used whenever the system is idle. If the timer resolution is increased, processor power management technologies may not be effective. The timer resolution may be increased due to multimedia playback or graphical animations. Current Timer Resolution (100ns units) 10000 Maximum Timer Period (100ns units) 156001 Platform Timer Resolution:Outstanding Kernel Timer Request A kernel component or device driver has requested a timer resolution smaller than the platform maximum timer resolution. Requested Period 10000 Request Count 2 Platform Timer Resolution:Outstanding Timer Request A program or service has requested a timer resolution smaller than the platform maximum timer resolution. Requested Period 10000 Requesting Process ID 8672 Requesting Process Path \Device\HarddiskVolume3\Program Files (x86)\Mozilla Firefox\firefox.exe Platform Timer Resolution:Outstanding Timer Request A program or service has requested a timer resolution smaller than the platform maximum timer resolution. Requested Period 100000 Requesting Process ID 1212 Requesting Process Path \Device\HarddiskVolume3\Windows\System32\svchost.exe Power Policy:802.11 Radio Power Policy is Maximum Performance (Plugged In) The current power policy for 802.11-compatible wireless network adapters is not configured to use low-power modes. CPU Utilization:Individual process with significant processor utilization. This process is responsible for a significant portion of the total processor utilization recorded during the trace. Process Name audiodg.exe PID 1304 Average Utilization (%) 4.73 Module Average Module Utilization (%) \Device\HarddiskVolume3\Windows\System32\msvcrt.dll 1.88 \Device\HarddiskVolume3\Windows\System32\MaxxAudioAPO5064.dll 1.77 \Device\HarddiskVolume3\Windows\System32\AudioEng.dll 0.80 CPU Utilization:Individual process with significant processor utilization. This process is responsible for a significant portion of the total processor utilization recorded during the trace. Process Name thunderbird.exe PID 6036 Average Utilization (%) 0.35 Module Average Module Utilization (%) \Device\HarddiskVolume3\Program Files (x86)\Mozilla Thunderbird\xul.dll 0.16 \Device\HarddiskVolume3\Program Files (x86)\Mozilla Thunderbird\mozjs.dll 0.05 \SystemRoot\System32\win32k.sys 0.03 CPU Utilization:Individual process with significant processor utilization. This process is responsible for a significant portion of the total processor utilization recorded during the trace. Process Name dwm.exe PID 1340 Average Utilization (%) 0.25 Module Average Module Utilization (%) \Device\HarddiskVolume3\Windows\System32\dwmcore.dll 0.08 \Device\HarddiskVolume3\Windows\System32\nvwgf2umx.dll 0.05 \SystemRoot\system32\ntoskrnl.exe 0.03 CPU Utilization:Individual process with significant processor utilization. This process is responsible for a significant portion of the total processor utilization recorded during the trace.

    Read the article

  • Electronic circuit simulator four-way flood-filling issues

    - by AJ Weeks
    I've made an electronic circuit board simulator which has simply 3 types of tiles: wires, power sources, and inverters. Wires connect to anything they touch, other than the sides of inverters; inverters have one input side and one output side; and finally power tiles connect in a similar manner as wires. In the case of an infinite loop, caused by the output of the inverter feeding into its input, I want inverters to oscillate (quickly turn on/off). I've attempted to implement a FloodFill algorithm to spread the power throughout the grid, but seem to have gotten something wrong, as only the tiles above the power source get powered (as seen below) I've attempted to debug the program, but have had no luck thus far. My code concerning the updating of power can be seen here.

    Read the article

  • Mouse Problem on Ubuntu 12.10

    - by KashmirHackers
    I had a strange mouse problem on Ubuntu 12.10(64-Bit), the problem is that when I turnoff power supply/power goes off, the red laser light of my mouse also goes off and my mouse stops working but it works fine when A/C power supply is on. First I thought my mouse or my laptop's USB ports had problem but since I am using Dual Boot with windows 7, I checked my mouse on windows 7 and it works fine, even I turn off power supply. Today,I thought that I should give a try to Linux Mint 14-RC (which is based on same Ubuntu 12.10) and after installing linux mint when I plugged in my mouse it worked fine even though power is off. Don't know what is really going on, and I am afraid if I reinstall my Ubuntu 12.10 the problem will remain.

    Read the article

  • ?Oracle Database 12c????ASM Scrubbing Disk Groups

    - by Liu Maclean(???)
    ?12.1?Oracle ASM??????????????????? ??Scrubbing Disk Groups, Disk Scrubbing???????????,?????Normal ??High Redundancy?disk group?????? Scrubbing ?????????????????Disk Scrubbing???disk group rebalancing???????I/O?????Disk Scrubbing??????I/O????? ?????????Scrubbing????,?????,????????????,?????ALTER DISKGROUP?????????: SQL> ALTER DISKGROUP data SCRUB POWER LOW; SQL> ALTER DISKGROUP data SCRUB FILE '+DATA/ORCL/ASKMACLEAN/example.266.806582193' REPAIR POWER HIGH FORCE; SQL> ALTER DISKGROUP data SCRUB DISK DATA_0005 REPAIR POWER HIGH FORCE; ?????SCRUB ?: ??REPAIR??????????,?????REPAIR,?SCRUB???????????????? ??POWER?????AUTO LOW HIGH ??MAX? ?POWER???,???AUTO????? ??WAIT ???????scrubbing ?????????WAIT???,?scrubbing??????scrubbing queue ??,??????? ?FORCE?????,?????I/O????????????????scrubbing ,????????

    Read the article

  • Delphi - Proper way to page though data.

    - by Brad
    I have a string list (TStrings) that has a couple thousand items in it. I need to process them in groups of 100. I basically want to know what the best way to do the loop is in Delphi. I'm hitting a brick wall when I'm trying to figure it out. Thanks unit Unit2; interface uses Windows, Messages, SysUtils, Variants, Classes, Graphics, Controls, Forms, Dialogs, StdCtrls; type TForm2 = class(TForm) Memo1: TMemo; Memo2: TMemo; Button1: TButton; procedure Button1Click(Sender: TObject); private { Private declarations } public { Public declarations } end; var Form2: TForm2; implementation Uses math; {$R *.dfm} procedure TForm2.Button1Click(Sender: TObject); var I:Integer; pages:Integer; str:string; begin pages:= ceil(memo1.Lines.Count/100) ; memo2.Lines.add('Total Pages: '+inttostr(pages)); memo2.Lines.add('Total Items: '+inttostr(memo1.Lines.Count)); // Should just do in batches of 100 VS entire list for I := 0 to memo1.lines.Count - 1 do begin if str '' then str:= str+#10+ memo1.Lines.Strings[i] else str:= memo1.Lines.Strings[i]; end; //I need to stop here every 100 items, then process the items. memo2.Lines.Add(str); end; end. Example form object Form2: TForm2 Left = 0 Top = 0 Caption = 'Form2' ClientHeight = 245 ClientWidth = 527 Color = clBtnFace Font.Charset = DEFAULT_CHARSET Font.Color = clWindowText Font.Height = -11 Font.Name = 'Tahoma' Font.Style = [] OldCreateOrder = False PixelsPerInch = 96 TextHeight = 13 object Memo1: TMemo Left = 16 Top = 8 Width = 209 Height = 175 Lines.Strings = ( '4xlt columbia thunder storm jacket' '5 things about thunder storms' 'a thunder storm with a lot of thunder ' 'and lighting sccreensaver' 'a thunder storm with a lot of thunder ' 'and lighting screensaver with no nag ' 'screens' 'all about thunder storms' 'all about thunderstorms for kids' 'amazing tornado videos and ' 'thunderstorm videos' 'are thunder storms louder in ohio?' 'bad thunder storms' 'bathing in thunder storm' 'best thunderstorm pictures' 'cartoon thunder storms' 'celtic thunder storm' 'central valley thunder storm' 'chicago thunderstorm pictures' 'cool thunderstorm pictures' 'current thunderstorm warnings' 'does thunder storms in december mean ' 'snow will be coming' 'facts about thunderstorms for kids' 'facts on thunderstorms for kids' 'fedex thunderstorm video' 'florida thunderstorms facts' 'free relaxing thunderstorm music' 'free soothing thunderstorm sounds ' 'online' 'free thunderstorm mp3' 'free thunderstorm mp3 download' 'free thunderstorm mp3 downloads' 'free thunderstorm mp3s' 'free thunderstorm music' 'free thunderstorm pictures' 'free thunderstorm sound effects' 'free thunderstorm sounds' 'free thunderstorm sounds cd' 'free thunderstorm sounds mp3' 'free thunderstorm sounds online' 'free thunderstorm soundscape' 'free thunderstorm video' 'free thunderstorm video download' 'free thunderstorm videos' 'god of storm and thunder' 'horses storm thunder rain' 'how do thunder storms form' 'how far away is a thunder storm' 'how long do thunder storms last' 'ice cube in a thunder storm' 'indoor thunderstorm safety tips' 'information about thunderstorms for kids' 'interesting thunderstorm facts' 'is it dangerous to shower during thunder ' 'storm' 'is there frequently thunder during snow ' 'storms' 'isolated thunderstorms' 'it'#39's just a thunder storm baby there is ' 'nothing you should fear lyrics' 'lightning & thunder storm safety' 'lightning and thunderstorm facts' 'lightning and thunderstorms facts' 'lightning and thunderstorms for kids' 'listen to thunderstorm sounds online' 'mississauga thunder storm' 'nature sounds free mp3 thunder storm' 'only about thunderstorms facts' 'original storm deep thunderstick' 'phone use during thunder storms' 'pictures of thunderstorms' 'pocono thunder storm' 'posters of thunder storms' 'power rangers ninja storm' 'power rangers thunder storm' 'power rangers thunder storm cast' 'power rangers thunder storm games' 'power rangers thunder storm morphers' 'power rangers thunder storm part 1' 'power rangers thunder storm part 2' 'power rangers thunderstorm' 'power rangers thunderstorm cannon' 'power rangers thunderstorm deluxe ' 'megazord' 'power rangers thunderstorm games' 'power rangers thunderstorm megazord' 'power rangers thunderstorm part 2' 'power rangers thunderstorm pictures' 'power rnager ninja storm thunder staff' 'powerful thunder and lightning storms' 'precambrian thunder storms' 'rain thunderstorm mp3' 'rain thunderstorm pictures' 'relaxing thunderstorm music' 'reminds me of ohio river thunder lighten ' 'storms' 'sacramento thunder storm' 'safety tips for when your caught in a ' 'thunder storm' 'scattered thunderstorms' 'schemer puts his head in the thunder ' 'storm' 'sedative thunder storm' 'server thunder storms' 'severe supercell thunderstorm pictures' 'severe thunder storm pictures' 'severe thunder storms' 'severe thunderstorm facts' 'severe thunderstorm pictures' 'severe thunderstorm pictures hail' 'severe thunderstorm pictures in alberta' 'severe thunderstorm pictures tornado' 'severe thunderstorm safety' 'severe thunderstorm safety tips' 'severe thunderstorm videos' 'severe thunderstorm warning' 'severe thunderstorm warning los ' 'angeles' 'severe thunderstorm warning signs' 'severe thunderstorm warnings' 'severe thunderstorms' 'severe thunderstorms facts' 'shakespeare use thunder storm for ' 'cosmic disorder julius caesar' 'soothing thunderstorm sounds online' 'sound effects of severe thunder storm' 'sound of rain storm finger snapping ' 'thunder chorus' 'split thunder storm' 'storm 3d thunder power' 'storm dark thunder' 'storm dark thunder bowling ball' 'storm dark thunder bowling ball sale' 'storm dark thunder for sale' 'storm dark thunder pearl' 'storm dark thunder pearl bowling ball' 'storm dark thunder review' 'storm dark thunder shirt' 'storm dark thunderball' 'storm deep thunder' 'storm deep thunder 11' 'storm deep thunder 15' 'storm deep thunder 15 lure' 'storm deep thunder 2' 'storm deep thunder lures' 'storm deep thunderstick' 'storm deep thunderstick crankbaits' 'storm deep thunderstick dts09' 'storm deep thunderstick jr' 'storm deep thunderstick lures' 'storm deep thundersticks' 'storm rolling thunder 3 ball roller' 'storm rolling thunder bowling bag' 'storm rolling thunder three ball bowling ' 'bag' 'storm shallow thunder' 'storm shallow thunder 15' 'storm thunder claw' 'storm thunder craw' 'storm watches thunder' 'storms with constant lightning and ' 'thunder non-stop' 'supercell thunder storms' 'supercell thunderstorm pictures' 'supercell thunderstorms' 'swimming pools thunder storms' 'tampa + lightning strikes + thunder ' 'storms' 'texas thunderstorm pictures' 'texas thunderstorm warnings' 'thunder and lightning storm' 'thunder and lighting storms' 'thunder and lightning storms' 'thunder bay snow storm video' 'thunder storm' 'thunder storm and windmill' 'thunder storm cd' 'thunder storm cloud' 'thunder storm clouds' 'thunder storm dog peppermint oil' 'thunder storm in winter' 'thunder storm in winter and weather ' 'prediction' 'thunder storm lx-3 & road blaster psx ' 'download' 'thunder storm occurances' 'thunder storm photos' 'thunder storm poems' 'thunder storm safety' 'thunder storm sign' 'thunder storm sounds' 'thunder storms' 'thunder storms and deaths' 'thunder storms and ilghting' 'thunder storms and lighting' 'thunder storms cd' 'thunder storms in the arctic arctic ' 'weather' 'thunder storms in winter' 'thunder storms on you tub' 'thunder storms pics' 'thunder storms with rain' 'thunderstorm' 'thunderstorm backgrounds' 'thunderstorm capital' 'thunderstorm capital 2008 dorfman' 'thunderstorm capital in boston' 'thunderstorm capital llc' 'thunderstorm capital of canada' 'thunderstorm capital of the us' 'thunderstorm capital of the world' 'thunderstorm facts' 'thunderstorm facts for kids' 'thunderstorm facts hail' 'thunderstorm facts tornadoes' 'thunderstorm mp3' 'thunderstorm mp3 download' 'thunderstorm mp3 download free' 'thunderstorm mp3 downloads' 'thunderstorm mp3 downloads free' 'thunderstorm mp3 files' 'thunderstorm mp3 free' 'thunderstorm mp3 free download' 'thunderstorm mp3 free downloads' 'thunderstorm mp3 torrent' 'thunderstorm mp3s' 'thunderstorm music' 'thunderstorm music cd' 'thunderstorm music downloads' 'thunderstorm music free' 'thunderstorm music playlists' 'thunderstorm music rain' 'thunderstorm pics' 'thunderstorm pictures' 'thunderstorm pictures for kids' 'thunderstorm safety' 'thunderstorm safety for kids' 'thunderstorm safety precautions' 'thunderstorm safety procedures' 'thunderstorm safety rules' 'thunderstorm safety tips' 'thunderstorm safety tips for kids' 'thunderstorm safety tips shelter' 'thunderstorm safety tips trees' 'thunderstorm sound effects' 'thunderstorm sound effects cd' 'thunderstorm sound effects download' 'thunderstorm sound effects free' 'thunderstorm sound effects free ' 'download' 'thunderstorm sound effects free music ' 'feature audio' 'thunderstorm sound effects mp3' 'thunderstorm sound effects rain' 'thunderstorm sounds' 'thunderstorm sounds cd' 'thunderstorm sounds download' 'thunderstorm sounds for sleep' 'thunderstorm sounds for sleeping' 'thunderstorm sounds free' 'thunderstorm sounds free download' 'thunderstorm sounds free downloads' 'thunderstorm sounds mp3' 'thunderstorm sounds mp3 download' 'thunderstorm sounds mp3 free' 'thunderstorm sounds online' 'thunderstorm sounds online for free' 'thunderstorm sounds online free' 'thunderstorm sounds sleep' 'thunderstorm sounds streaming' 'thunderstorm sounds torrent' 'thunderstorm soundscape' 'thunderstorm soundscapes' 'thunderstorm video' 'thunderstorm video clips' 'thunderstorm video download' 'thunderstorm video downloads' 'thunderstorm videos' 'thunderstorm videos for kids' 'thunderstorm videos lightning' 'thunderstorm videos online' 'thunderstorm wallpaper' 'thunderstorm warning' 'thunderstorm warning brisbane' 'thunderstorm warning definition' 'thunderstorm warning los angeles' 'thunderstorm warning san diego' 'thunderstorm warning san mateo county' 'thunderstorm warning santa barbara' 'thunderstorm warning santa clara' 'thunderstorm warning santa clara ' 'county' 'thunderstorm warning signal' 'thunderstorm warning signs' 'thunderstorm warning vs watch' 'thunderstorm warnings' 'thunderstorm warnings and watches' 'thunderstorm warnings for nj' 'thunderstorm warnings qld' 'thunderstorms' 'thunderstorms facts' 'thunderstorms facts for kids' 'thunderstorms for kids' 'tornados and thunder storms animated' 'understanding thunderstorms for kids' 'watch thunderstorm videos' 'weather underground forecast ' 'thunderstorms' 'what causes thunder storms' 'what is a thunder storm' 'where d thunder storms occur') TabOrder = 0 end object Memo2: TMemo Left = 240 Top = 8 Width = 265 Height = 129 Lines.Strings = ( 'Memo2') TabOrder = 1 end object Button1: TButton Left = 384 Top = 184 Width = 75 Height = 25 Caption = 'Button1' TabOrder = 2 OnClick = Button1Click end end

    Read the article

  • MySQL InnoDB Corruption after power outage, possible to recover?

    - by Tim Hackett
    Hey Guys, I recently started trying to get Redmine up and running after a power outage that seems to have corrupted our InnoDB database in MySQL. Redmine had an extensive set of documentation that I would like to get even if redmine isn't able to run. The service fails on startup. I have tried inserting innodb_force_recovery = 4 per the documentation from the url in the error log. (also tried 1 thru 6 as I have backed up all directories after the corruption) I have verified through "mysqld-nt --print-defaults" that it is starting with the recovery option in the params. The machine is running Windows Server 2003 SP2, Xeon E5335 with 2GB RAM, MySQL is not mirrored to another machine, nor is the machine a mirror. I do not have any backups because the previous person did not set them up. Here is the error log: InnoDB: The log sequence number in ibdata files does not match InnoDB: the log sequence number in the ib_logfiles! 100308 14:50:01 InnoDB: Database was not shut down normally! InnoDB: Starting crash recovery. InnoDB: Reading tablespace information from the .ibd files... InnoDB: Restoring possible half-written data pages from the doublewrite InnoDB: buffer... 100308 14:50:02 InnoDB: Error: page 7 log sequence number 0 935521175 InnoDB: is in the future! Current system log sequence number 0 933419020. InnoDB: Your database may be corrupt or you may have copied the InnoDB InnoDB: tablespace but not the InnoDB log files. See InnoDB: http://dev.mysql.com/doc/refman/5.0/en/forcing-recovery.html InnoDB: for more information. 100308 14:50:02 InnoDB: Error: page 2 log sequence number 0 935517607 InnoDB: is in the future! Current system log sequence number 0 933419020. InnoDB: Your database may be corrupt or you may have copied the InnoDB InnoDB: tablespace but not the InnoDB log files. See InnoDB: http://dev.mysql.com/doc/refman/5.0/en/forcing-recovery.html InnoDB: for more information. 100308 14:50:02 InnoDB: Error: page 11 log sequence number 0 935517607 InnoDB: is in the future! Current system log sequence number 0 933419020. InnoDB: Your database may be corrupt or you may have copied the InnoDB InnoDB: tablespace but not the InnoDB log files. See InnoDB: http://dev.mysql.com/doc/refman/5.0/en/forcing-recovery.html InnoDB: for more information. 100308 14:50:02 InnoDB: Error: page 5 log sequence number 0 972973045 InnoDB: is in the future! Current system log sequence number 0 933419020. InnoDB: Your database may be corrupt or you may have copied the InnoDB InnoDB: tablespace but not the InnoDB log files. See InnoDB: http://dev.mysql.com/doc/refman/5.0/en/forcing-recovery.html InnoDB: for more information. 100308 14:50:02 InnoDB: Error: page 6 log sequence number 0 972984051 InnoDB: is in the future! Current system log sequence number 0 933419020. InnoDB: Your database may be corrupt or you may have copied the InnoDB InnoDB: tablespace but not the InnoDB log files. See InnoDB: http://dev.mysql.com/doc/refman/5.0/en/forcing-recovery.html InnoDB: for more information. 100308 14:50:02 InnoDB: Error: page 1577 log sequence number 0 972737368 InnoDB: is in the future! Current system log sequence number 0 933419020. InnoDB: Your database may be corrupt or you may have copied the InnoDB InnoDB: tablespace but not the InnoDB log files. See InnoDB: http://dev.mysql.com/doc/refman/5.0/en/forcing-recovery.html InnoDB: for more information. InnoDB: Error: trying to access page number 4294965119 in space 0, InnoDB: space name .\ibdata1, InnoDB: which is outside the tablespace bounds. InnoDB: Byte offset 0, len 16384, i/o type 10. InnoDB: If you get this error at mysqld startup, please check that InnoDB: your my.cnf matches the ibdata files that you have in the InnoDB: MySQL server. 100308 14:50:02InnoDB: Assertion failure in thread 960 in file .\fil\fil0fil.c line 3959 InnoDB: We intentionally generate a memory trap. InnoDB: Submit a detailed bug report to http://bugs.mysql.com. InnoDB: If you get repeated assertion failures or crashes, even InnoDB: immediately after the mysqld startup, there may be InnoDB: corruption in the InnoDB tablespace. Please refer to InnoDB: http://dev.mysql.com/doc/refman/5.0/en/forcing-recovery.html InnoDB: about forcing recovery. 100308 14:50:02 [ERROR] mysqld-nt: Got signal 11. Aborting! 100308 14:50:02 [ERROR] Aborting 100308 14:50:02 [Note] mysqld-nt: Shutdown complete

    Read the article

  • How do you raise a Java BigInteger to the power of a BigInteger without doing modular arithmetic?

    - by angstrom91
    I'm doing some large integer computing, and I need to raise a BigInteger to the power of another BigInteger. The .pow() method does what I want, but takes an int value as an argument. The .modPow method takes a BigInteger as an argument, but I do not want an answer congruent to the value I'm trying to compute. My BigInteger exponent is too large to be represented as an int, can someone suggest a way to work around this limitation?

    Read the article

< Previous Page | 42 43 44 45 46 47 48 49 50 51 52 53  | Next Page >