  • Server restarted while rebuilding array, what to do?

    - by user239054
    It's a HP ProLiant DL380 Generation 7, that has four hard drives, one is dead, I suppose that another one is dead too, but is there any way to force the array to rebuild again? The server has restarted while it was rebuilding an array. My windows server(2008) that is on it won't boot, it goes directly to system recovery screen. I have an image backup, would restoring it be my only option?If I restore, it will get back to regular automatically or will I have to configure something?

    Read the article

  • New Oracle VM Hardware Certifications

    - by Chris Kawalek
    We've received inquiries from the community on certification of Oracle VM 3.0 on HP Proliant systems. We're pleased to update that we've recently completed certification of the HP Proliant systems for Oracle VM 3.0. The newly certified systems are: ProLiant DL980 G7 Hewlett Packard Oracle VM 3.0 x86_64 ProLiant BL680c G7 Hewlett Packard Oracle VM 3.0 x86_64  ProLiant BL465c G7 Hewlett Packard Oracle VM 3.0 x86_64  ProLiant BL460c G7 Hewlett Packard Oracle VM 3.0 x86_64  ProLiant DL380 G7 Hewlett Packard Oracle VM 3.0 x86_64 See this Oracle VM Certified Hardware page for more details. For more information, please go to the Oracle Virtualization web page, or  follow us at :  Twitter   Facebook YouTube Newsletter

    Read the article

  • Install server 2012 on HP ML110 G7 with B110i controller, no disks found

    - by Molotch
    I'm trying to install Server 2012 on a HP ML110 G7 with a B110i controller and four non hot-swappable SATA drives. I just can't get the Server 2012 boot disk PE environment to find any disks. I have downloaded the latest SPP (Service Pack for Proliant 2012.10) and flashed the BIOS. I have tried two different HP drivers for B110i and Windows X64, 6.18.0.64 and 6.18.2.64 to no avail. I have tried setting the controller to both AHCI and legacy mode in the BIOS, no difference. HP:s SmartStart disc for G7 servers only support installation of up to Windows Server 2008R2. HP:s installation instructions for Server 2012 Essentials says boot from the windows disk and use the storage drivers found on the SPP (I can't find any storage drivers on the SPP disk).

    Read the article

  • CentOS 5.5 APIC issue on ESX 4.1 & ML115

    - by Adnan
    Hi, I've just installed vSphere 4.1 on an HP ProLiant ML115 G5 Quad-core and am trying to install CentOS 5.5 as a guest system. However, when the guest boots up I get a calibrate_APIC_clock warning and a kernel panic message. I've come across this knowledge base article on the vmware website which suggests moving the guest onto another Intel based host (!). Funnily enough I don't have a collection of spare host servers sitting around, so can anyone suggest another solution? Alternatively, would installing an earlier version of CentOS get around this issue, or would a yum update put me back to square one? How about BIOS settings, could anything be tweaked there? Thanks.

    Read the article

  • Kernel Panic - Not Syncing: Fatal exception

    - by user3513346
    Server (HP Proliant D320e G8 v2) froze at this screen during boot today (running CentOS 6.5): I was able to get the server to boot after a 'press and hold'. I've been having many problems with the server lately - mainly related to the iLO and being unable to install CentOS 7. Could someone please help me decode this screen? Does it suggest there could be a serious problem? Or does this just happen sometimes? It is possible that the OS wasn't 'shutdown' properly before the failed boot.

    Read the article

  • VMWare - persistent "Host memory status" alarm in vSphere

    - by ewwhite
    I have a particular VMWare ESX 4.1 host that has a very persistent "Host memory status" alarm. This is running on an HP ProLiant DL360 G7 server. The HP ILO and System Management agents don't know any errors. If I clear the alarm in the vSphere client, it returns within a day. I've tried reseating DIMMs, however, the error does not indicate a problem with a specific module. There's another host in the cluster with an identical configuration. It's not exhibiting any issues. Any thoughts? This is touched on briefly on other forums (and here) with no clear resolution.

    Read the article

  • ML 350 additional SATA RAID controller (mirror only)

    - by Nicholas
    I have a Proliant ML350 G8 with two SAS raid arrays currently set up - thereby maxing the default P420i raid controller. I need to set up a large video dump space in addition to this existing set-up (for non backed up, non-critical, temporary storage). I had planned to just add a 2TB SATA disk and plug it into the motherboard. However I it occurred to me the motherboard might have built-in mirror RAID support? Therefore I could use two SATA disks and have some semblance of redundancy. Is this possible? Or would I need to get a cheap raid card? Any recommendations?

    Read the article

  • New standalone ESXi 5 deployments - USB versus SD card?

    - by ewwhite
    Now that the old full VMWare ESX with service console is no longer, I'm redeploying some standalone ESXi servers. I'm using HP ProLiant ML and DL G6 and G7 servers. Does it make more sense to utilize the internal USB port for ESXi or the internal SD card slot? I'm using the HP ESXi 5 build, but am not sure what the recommended practice is. Any recommendations on cards/USB drives for this purpose? BTW - these will be all-in-one storage servers with the onboard disk storage presented via PCIe passthrough.

    Read the article

  • HP ML150 G6 upgrading RAM/CPU beyond specs?

    - by Morten Green Hermansen
    I am being told that some limits on some HP servers can be crossed. Do any of you have any experience with that? A ML150/G6 is limited to 48GB RAM but I have been talking to a German company that guaranties me that this server will be able to be upgraded to 384GB RAM (using 32GB memory modules and 2 CPUs) http://www.compuram.de/en/memory,HP+%28-Compaq%29,Server,Proliant,ML150+G6.htm Can this really be true? The server that I have is using E5504 CPUs but will I be able to upgrade to any CPU that is using a LGA1366 socket? All from a low wattage L5640 all the way to the 6 core, high wattage versions like an X5650? (If cooling and power is adequate ofcause). Is there any limitation with powerregulators and chipset (Intel 5500). I am looking forward to any reply. Thanks in advance and best regards, - Morten Green Hermansen, Fanitas

    Read the article

  • replace controller, add second controller, or use expander?

    - by longneck
    I have a Proliant DL380 G6 that I am re-purposing as a Hyper-V host for a new, off-site data center that will host our DR services. The server currently has a P410i controller with the 512MB BBWC module. The drives installed are SFF 6G 10K drives. I plan to add the HP 516914-B21 drive cage, which gives me 8 more SFF drives, bringing the total to 16. To get the additional 8 drives connected, I have one of three choices: Install a new controller that can support 16 drives. Install a second controller. Install a SAS expander, such as the HP 468406-B21 recommended by HP's spec sheet for my server. My question is: how do I know if I'm going hit a performance ceiling by putting 16 drives on the P410i or using the expander? And if I am, how do I select an appropriate controller? I'm not sure what specifications I should be looking at.

    Read the article

  • Openfiler iSCSI performance

    - by Justin
    Hoping someone can point me in the right direction with some iSCSI performance issues I'm having. I'm running Openfiler 2.99 on an older ProLiant DL360 G5. Dual Xeon processor, 6GB ECC RAM, Intel Gigabit Server NIC, SAS controller with and 3 10K SAS drives in a RAID 5. When I run a simple write test from the box directly the performance is very good: [root@localhost ~]# dd if=/dev/zero of=tmpfile bs=1M count=1000 1000+0 records in 1000+0 records out 1048576000 bytes (1.0 GB) copied, 4.64468 s, 226 MB/s So I created a LUN, attached it to another box I have running ESXi 5.1 (Core i7 2600k, 16GB RAM, Intel Gigabit Server NIC) and created a new datastore. Once I created the datastore I was able to create and start a VM running CentOS with 2GB of RAM and 16GB of disk space. The OS installed fine and I'm able to use it but when I ran the same test inside the VM I get dramatically different results: [root@localhost ~]# dd if=/dev/zero of=tmpfile bs=1M count=1000 1000+0 records in 1000+0 records out 1048576000 bytes (1.0 GB) copied, 26.8786 s, 39.0 MB/s [root@localhost ~]# Both servers have brand new Intel Server NIC's and I have Jumbo Frames enabled on the switch, the openfiler box as well as the VMKernel adapter on the ESXi box. I can confirm this is set up properly by using the vmkping command from the ESXi host: ~ # vmkping 10.0.0.1 -s 9000 PING 10.0.0.1 (10.0.0.1): 9000 data bytes 9008 bytes from 10.0.0.1: icmp_seq=0 ttl=64 time=0.533 ms 9008 bytes from 10.0.0.1: icmp_seq=1 ttl=64 time=0.736 ms 9008 bytes from 10.0.0.1: icmp_seq=2 ttl=64 time=0.570 ms The only thing I haven't tried as far as networking goes is bonding two interfaces together. I'm open to trying that down the road but for now I am trying to keep things simple. I know this is a pretty modest setup and I'm not expecting top notch performance but I would like to see 90-100MB/s. Any ideas?

    Read the article

  • Is it possible to shrink the size of an HP Smart Array logical drive?

    - by ewwhite
    I know extension is quite possible using the hpacucli utility, but is there an easy way to reduce the size of an existing logical drive (not array)? The controller is a P410i in a ProLiant DL360 G6 server. I'd like to reduce logicaldrive 1 from 72GB to 40GB. => ctrl all show config detail Smart Array P410i in Slot 0 (Embedded) Bus Interface: PCI Slot: 0 Serial Number: 5001438006FD9A50 Cache Serial Number: PAAVP9VYFB8Y RAID 6 (ADG) Status: Disabled Controller Status: OK Chassis Slot: Hardware Revision: Rev C Firmware Version: 3.66 Rebuild Priority: Medium Expand Priority: Medium Surface Scan Delay: 3 secs Surface Scan Mode: Idle Queue Depth: Automatic Monitor and Performance Delay: 60 min Elevator Sort: Enabled Degraded Performance Optimization: Disabled Inconsistency Repair Policy: Disabled Wait for Cache Room: Disabled Surface Analysis Inconsistency Notification: Disabled Post Prompt Timeout: 15 secs Cache Board Present: True Cache Status: OK Accelerator Ratio: 25% Read / 75% Write Drive Write Cache: Enabled Total Cache Size: 512 MB No-Battery Write Cache: Disabled Cache Backup Power Source: Batteries Battery/Capacitor Count: 1 Battery/Capacitor Status: OK SATA NCQ Supported: True Array: A Interface Type: SAS Unused Space: 412476 MB Status: OK Logical Drive: 1 Size: 72.0 GB Fault Tolerance: RAID 1+0 Heads: 255 Sectors Per Track: 32 Cylinders: 18504 Strip Size: 256 KB Status: OK Array Accelerator: Enabled Unique Identifier: 600508B1001C132E4BBDFAA6DAD13DA3 Disk Name: /dev/cciss/c0d0 Mount Points: /boot 196 MB, / 12.0 GB, /usr 8.0 GB, /var 4.0 GB, /tmp 2.0 GB OS Status: LOCKED Logical Drive Label: AE438D6A5001438006FD9A50BE0A Mirror Group 0: physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 146 GB, OK) physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 146 GB, OK) Mirror Group 1: physicaldrive 1I:1:3 (port 1I:box 1:bay 3, SAS, 146 GB, OK) physicaldrive 1I:1:4 (port 1I:box 1:bay 4, SAS, 146 GB, OK) SEP (Vendor ID PMCSIERA, Model SRC 8x6G) 250 Device Number: 250 Firmware Version: RevC WWID: 5001438006FD9A5F Vendor ID: PMCSIERA Model: SRC 8x6G

    Read the article

  • 2008 Sever Randomly reboots.

    - by Jeff
    I'm out of ideas here. We have a 2008 Server that keeps rebooting 2-3 times a day at completely random times with an "Unexpected Shutdown" event. There are no Dumps, no events leading to it just like it loses power then comes back online. I ran a Diagnostic of the power supply and it has had continuous power for months. In addition, the temperature of the processors are maxing out at 40 degrees Celsius. Anyone have any ideas how to figure out why this is restarting all the time? This is a DMZed Web server so it doesn't do too much process wise. Here are the specs: Host Name: ~~~ OS Name: Microsoft Windows Server 2008 R2 Standard OS Version: 6.1.7600 N/A Build 7600 OS Manufacturer: Microsoft Corporation OS Configuration: Standalone Server OS Build Type: Multiprocessor Free Registered Owner: Windows User Registered Organization: Product ID: ~~~ Original Install Date: 5/27/2010, 4:25:47 PM System Boot Time: 2/14/2011, 5:35:01 PM System Manufacturer: HP System Model: ProLiant DL380 G6 System Type: x64-based PC Processor(s): 1 Processor(s) Installed. [01]: Intel64 Family 6 Model 26 Stepping 5 GenuineIntel ~1586 Mhz BIOS Version: HP P62, 8/16/2010 Windows Directory: C:\Windows System Directory: C:\Windows\system32 Boot Device: \Device\HarddiskVolume1 System Locale: en-us;English (United States) Input Locale: en-us;English (United States) Time Zone: (UTC-05:00) Eastern Time (US & Canada) Total Physical Memory: 4,086 MB Available Physical Memory: 2,775 MB Virtual Memory: Max Size: 8,170 MB Virtual Memory: Available: 6,691 MB Virtual Memory: In Use: 1,479 MB Page File Location(s): C:\pagefile.sys

    Read the article

  • Four disks - RAID 10 or two mirrored pairs?

    - by ewwhite
    I have this discussion with developers quite often. The context is an application running in Linux that has a medium amount of disk I/O. The servers are HP ProLiant DL3x0 G6 with four disks of equal size @ 15k rpm, backed with a P410 controller and 512MB of battery or flash-based cache. There are two schools of thought here, and I wanted some feedback... 1). I'm of the mind that it makes sense to create an array containing all four disks set up in a RAID 10 (1+0) and partition as necessary. This gives the greatest headroom for growth, has the benefit of leveraging the higher spindle count and better fault-tolerance without degradation. 2). The developers think that it's better to have multiple RAID 1 pairs. One for the OS and one for the application data, citing that the spindle separation would reduce resource contention. However, this limits throughput by halving the number of drives and in this case, the OS doesn't really do much other than regular system logging. Additionally, the fact that we have the battery RAID cache and substantial RAM seems to negate the impact of disk latency... What are your thoughts?

    Read the article

  • Broadcom HT1100 SATA controller not working properly with 1TB drives

    - by Jeff C
    I've been using RHEL distro's for several years and always managed to find the answers until now. I know this is more of a hardware issue, but I've been working on this for over a week and trust Linux and the IT community to help more then HP. I have CentOS 6.3 installed on an HP ProLiant DL145 G3 server with the BroadCom HT1100 IO controller and ServerWorks SATA Controller MMIO BIOS v3.0.0015.6 Firmware. This controller does not support large drives fully. Here's what I've tried and the results; Stock setup - Freezes on the ServerWorks POST screen. Can't even enter CMOS without disconnecting the drives. If I simply disconnect the SATA cables before it gets to the ServerWorks screen and reconnect afterwards I can boot from a CD, USB, PXE fine. However fiddling with cables at ever boot isn't practical. If I enter the BIOS config I can set it to not try booting the drives but leave the controller enabled. This lets me boot normally but the drives are not visible in the OS (live CDs or USB installed). I used method #2 to install and update CentOS. I have the /boot partition on a USB drive (everything else is on the SATA drives in software RAID1) hoping that would work around the issue but I get this Kernel panic - not syncing:Attempted to kill init! Pid: 1, comm: init Not tainted 2.6.32-279.9.1.el6.x86_6 #1 Call Trace: [<ffffffff814fd6ba>] ? panic+0xa0/0x168 [<ffffffff81070c22>] ? do_exit+0x862/0x870 [<ffffffff8117cdb5>] ? fput+0x25/0x30 [<ffffffff81070c88>] ? do_group_exit+0x58/0xd0 [<ffffffff81070d17>] ? sys_exit_group+0x17/0x20 [<ffffffff8100b0f2>] ? system_call_fastpath+0x16/0x1b panic occured, switching back to text console I'm sure it should be possible to talk to the drives without the BIOS boot check since the BIOS doesn't see them in method #2 either, their disconnected when it checks, but Linux sees them fine. If anyone could help figure out how I would greatly appreciate it! The other possible option I've come across is a complex firmware update. Tyan has a few boards on their website with the HT1100 and a ServerWorks v3.0.0015.7 update which says "adds support for TB drives" in the release notes. If someone could help me get the Tyan SATA firmware into the HP ROM file so I could just reflash that would also be very much appreciated. Thanks for any help you guys can offer!

    Read the article

  • Integrating HP Systems Insight Manager into an existing environment

    - by ewwhite
    I'm working with an environment that spans multiple data centers/sites and consists primarily of HP ProLiant servers (G5-G7) running Linux. The mix is 30% RHEL/CentOS, the rest are Gentoo :(. I also have a few dozen virtual machines running back-office and Windows servers on VMWare ESX hosts. I run OpenNMS to pull SNMP data from the various server nodes and networking devices. While OpenNMS works wonderfully for up/down, thresholds and notifications, it's native handling of traps is a little rough and the graphs are not particularly pretty. I use Orca/RRD graphs for performance trending and nice graphs. I'm tasked with inventorying the environment and wanted to come up with a clean way to organize server information. Since my environment is mostly HP, I've been playing with HP Systems Insight Manager as a way to extract server data and to deploy HP health/monitoring packages and firmware. The Gentoo systems eventually have to be converted to CentOS, so getting a quick assessment of what hardware is where would be great. Although I've read through a few hundred pages of HP manuals, I'm having a difficult time understanding how to get HP SIM to do what I want, though. My main problems are: I have about 40 subnets to deal with; 98% connected with private lines to facilities across the globe. I don't want to initiate an HP SIM discovery only to pull back every piece of intermediate networking hardware and equipment from all of the locations. I'd like this to focus on the servers. I have OpenNMS configured to accept traps. I don't want HP SIM to duplicate that effort. It seems like the built-in software deployment tool wants to overwrite the trapsink parameters for the systems it encounters during discovery. I have about 10 administrative username/password combinations in use across this infrastructure. Is there a more efficient way to get HP SIM to do the discovery or break discovery into manageable chunks? In terms of general workflow, do people typically install the HP Management Agents during the initial OS deployment (e.g. kickstart post script) or afterwards from HP SIM? Is HP SIM too thick/fat to be an inventory tool? I can't tell if it's meant to be used standalone or alongside other monitoring products. Since the majority of the systems I'm trying to track are those running Gentoo (in order to plan the move to CentOS), is there any way for HP SIM to extract system model information from them ( like dmidecode)? I have systems here where I may have an SSH key established, but not direct user or login access. Is there a way for me to import an SSH private/public key pair into HP SIM to reach out to the servers that can't accept standard credentials? There are a handful of sites where I have inconsistent access or have a double-NAT situation. I may be able to poke a server, but it may not be able to find its way back to the management system. Is there a workaround for this? The certificate configuration for HP SIM seems complicated. What is the preferred setup for trust between systems? I'd also appreciate any notes or recommendations to using this product. Or if there's a better way to do this, I'd like to know.

    Read the article

  • moving raid 10 to another identical server both on Smart Array 6i controllers

    - by SalimQrdl
    I have dead HP DL 380G4 with RAID 1+0 with 1 logical volume from 4x72GB drives on built-in Smart Array 6i 128Mb BBWC. It was shut down properly. It seems it was usual death for Proliant with ILO led 2,3,8 lighting. I want to move array to another identical server with same raid firmware level. What is the best strategy?: I have RAID 1+0 on bay 0 bay 1 bay 2 bay 3 As I understand bay0+bay1 are in RAID 1 , bay2+bay3 are in RAID 1, and both RAID 1 pairs are in RAID 0. So should I : Clear RAID config on new server, insert bay 0, bay 2 and power-on or Create RAID 1+0 with 1 logical volume from clear HDDs , and then poweroff ,remove HDDs and insert 2 HDDs(bay 0, bay 2) from old RAID 1+0. then power-on. (each hdd has its raid position info stored but may be could work on same config) According to documentation for Smart Array 6i it could be possible to migrate. however one requirement point is unclear for me Before you move drives, the following conditions must be met: • The array is in its original configuration. " What is orginal and non-original config for RAID 1+0? Another point "If you want to move an array to another controller, you must also consider the following additional limitations: • All drives in the array must be moved at the same time." I want to move one hdd from each RAID 1 pair. to have mirrors untouched just in case. Do they mean to move all 4 simultaniously? Smart Array 6i User Guide: Moving Drives and Arrays You can move drives to other ID positionson the same array controller. You can also move a complete arrayfrom one controller to another, even if the controllers are on different servers. Before you move drives, the following conditions must be met: • If moving thedrives to a different server, the new server must have enough empty bays to accommodate all the drives simultaneously. • The move will not result in more than 14 physical drives per controller channel. • No controller will be configured with more than 32 logical volumes. • The array has no failed or missing drives. • The array is in its original configuration. • The controller is not reading from or writing to any of the spare drives in the array. • The controller is not running capacity expansion, capacity extension, or RAID or stripe size migration. • The controller is using the latestfirmware version (recommended). If you want to move an array to another controller, you must also consider the following additional limitations: • All drives in the array must be moved at the same time. • In most cases, a moved array (and the logical drives that it contains) can still undergo arraycapacity expansion, logical drive capacity extension, or migration of RAID level orstripe size. When all the conditions have been met: Back up all data before removing any drives or changing configuration. This step is requiredif you are moving data-containing drives from a controller that does not have a battery-backed cache. Power down the system. If you are moving an array from a controller that contains a RAID ADG logical volume to a controller that does not support RAID ADG: Move the drives. Power up the system. If a 1724 POST message is displayed, drive positions were changed successfully and the configuration was updated. If a 1785 (NotConfigured)POST message is displayed: a. Power down the system immediately to prevent data loss. b. Return the drives to their original locations. c. Restore the data from backup, if necessary. Check the new drive configuration byrunning ORCA or ACU ("Configuring an Array" on page 9).

    Read the article

  • ESXi v5.5 is having random crashes

    - by Darkmage
    HW: Type: HP Proliant ML350 G5 RAM 22GB CPU 1 x Intel Xenon E5405 2.00GHz OP: ESXi 5.5 just updated from 5.1 to try and fix the crashes occurring on ESXi 5.1 on same hardware. I'm trying to find the error on why one of our servers is crashing, it has had two lock ups in 24 hours now. The internal error light on the front is blinking red, on the inside only "#5 and #6 page 76 manual" the "Processor 2" light "amber" and the "Power" light "green" is shining. in the logs the only errors i can see in the relevant time frame is in log under. Is this the reason? or is there anything else i can do to try and log/locate the error. from zcat syslog.6.gz | less 2014-05-26T11:55:47Z sfcbd[35064]: Error opening socket pair for getProviderContext: Too many open files 2014-05-26T11:55:47Z sfcbd[35064]: Failed to set recv timeout (30) for socket -1. Errno = 9 2014-05-26T11:55:47Z sfcbd[35064]: Failed to set timeout for local socket (e.g. provider) 2014-05-26T11:55:47Z sfcbd[35064]: spGetMsg receiving from -1 35064-9 Bad file descriptor 2014-05-26T11:55:47Z sfcbd[35064]: rcvMsg receiving from -1 35064-9 Bad file descriptor 2014-05-26T11:55:47Z sfcb-ProviderManager[34828]: SendMsg sending to 1 34828-9 Bad file descriptor 2014-05-26T11:55:47Z sfcb-ProviderManager[34828]: SendMsg sending to 1 34828-9 Bad file descriptor 2014-05-26T11:55:47Z sfcb-ProviderManager[34828]: SendMsg sending to 1 34828-9 Bad file descriptor 2014-05-26T11:55:47Z sfcbd[35064]: Error opening socket pair for getProviderContext: Too many open files 2014-05-26T11:55:47Z sfcbd[35064]: Failed to set recv timeout (30) for socket -1. Errno = 9 2014-05-26T11:55:47Z sfcbd[35064]: Failed to set timeout for local socket (e.g. provider) 2014-05-26T11:55:47Z sfcbd[35064]: spGetMsg receiving from -1 35064-9 Bad file descriptor 2014-05-26T11:55:47Z sfcbd[35064]: rcvMsg receiving from -1 35064-9 Bad file descriptor 2014-05-26T11:55:47Z sfcb-ProviderManager[34828]: SendMsg sending to 1 34828-9 Bad file descriptor 2014-05-26T11:55:47Z sfcb-ProviderManager[34828]: SendMsg sending to 1 34828-9 Bad file descriptor 2014-05-26T11:55:47Z sfcb-ProviderManager[34828]: SendMsg sending to 1 34828-9 Bad file descriptor 2014-05-26T11:55:53Z sfcb-ProviderManager[34828]: SendMsg sending to 1 34828-9 Bad file descriptor 2014-05-26T11:55:57Z sfcb-ProviderManager[34828]: SendMsg sending to 1 34828-9 Bad file descriptor 2014-05-26T11:56:01Z sfcb-ProviderManager[34828]: SendMsg sending to 1 34828-9 Bad file descriptor 2014-05-26T11:56:04Z sfcb-ProviderManager[34828]: SendMsg sending to 1 34828-9 Bad file descriptor 2014-05-26T11:56:15Z sfcb-ProviderManager[34828]: SendMsg sending to 1 34828-9 Bad file descriptor 2014-05-26T11:56:17Z sfcbd[35064]: Error opening socket pair for getProviderContext: Too many open files 2014-05-26T11:56:17Z sfcbd[35064]: Failed to set recv timeout (30) for socket -1. Errno = 9 2014-05-26T11:56:17Z sfcbd[35064]: Failed to set timeout for local socket (e.g. provider) 2014-05-26T11:56:17Z sfcbd[35064]: spGetMsg receiving from -1 35064-9 Bad file descriptor 2014-05-26T11:56:17Z sfcbd[35064]: rcvMsg receiving from -1 35064-9 Bad file descriptor 2014-05-26T11:56:17Z sfcb-ProviderManager[34828]: SendMsg sending to 1 34828-9 Bad file descriptor 2014-05-26T11:56:17Z sfcb-ProviderManager[34828]: SendMsg sending to 1 34828-9 Bad file descriptor 2014-05-26T11:56:17Z sfcb-ProviderManager[34828]: SendMsg sending to 1 34828-9 Bad file descriptor 2014-05-26T11:56:17Z sfcbd[35064]: Error opening socket pair for getProviderContext: Too many open files 2014-05-26T11:56:17Z sfcbd[35064]: Failed to set recv timeout (30) for socket -1. Errno = 9 2014-05-26T11:56:17Z sfcbd[35064]: Failed to set timeout for local socket (e.g. provider) 2014-05-26T11:56:17Z sfcbd[35064]: spGetMsg receiving from -1 35064-9 Bad file descriptor 2014-05-26T11:56:17Z sfcbd[35064]: rcvMsg receiving from -1 35064-9 Bad file descriptor 2014-05-26T11:56:17Z sfcb-ProviderManager[34828]: SendMsg sending to 1 34828-9 Bad file descriptor 2014-05-26T11:56:17Z sfcb-ProviderManager[34828]: SendMsg sending to 1 34828-9 Bad file descriptor 2014-05-26T11:56:17Z sfcb-ProviderManager[34828]: SendMsg sending to 1 34828-9 Bad file descriptor 2014-05-26T11:56:23Z sfcb-ProviderManager[34828]: SendMsg sending to 1 34828-9 Bad file descriptor 2014-05-26T11:56:27Z sfcb-ProviderManager[34828]: SendMsg sending to 1 34828-9 Bad file descriptor 2014-05-26T11:56:31Z sfcb-ProviderManager[34828]: SendMsg sending to 1 34828-9 Bad file descriptor 2014-05-26T11:56:34Z sfcb-ProviderManager[34828]: SendMsg sending to 1 34828-9 Bad file descriptor 2014-05-26T11:56:34Z sfcb-ProviderManager[34828]: SendMsg sending to 1 34828-9 Bad file descriptor 2014-05-26T11:56:34Z sfcb-ProviderManager[34828]: SendMsg sending to 1 34828-9 Bad file descriptor 2014-05-26T11:56:34Z sfcb-ProviderManager[34828]: SendMsg sending to 1 34828-9 Bad file descriptor 2014-05-26T11:56:34Z sfcb-ProviderManager[34828]: SendMsg sending to 1 34828-9 Bad file descriptor 2014-05-26T11:56:44Z sfcb-ProviderManager[34828]: SendMsg sending to 1 34828-9 Bad file descriptor 2014-05-26T11:56:44Z sfcb-ProviderManager[34828]: SendMsg sending to 1 34828-9 Bad file descriptor 2014-05-26T11:56:44Z sfcb-ProviderManager[34828]: SendMsg sending to 1 34828-9 Bad file descriptor 2014-05-26T11:56:44Z sfcb-ProviderManager[34828]: SendMsg sending to 1 34828-9 Bad file descriptor 2014-05-26T11:56:46Z sfcb-ProviderManager[34828]: SendMsg sending to 1 34828-9 Bad file descriptor 2014-05-26T11:56:48Z sfcbd[35064]: Error opening socket pair for getProviderContext: Too many open files -- manual

    Read the article

  • HP DL160G6 bios update fails

    - by Bojo
    I tried to update the BIOS from my HP DL160G6's. Unfortunately the Windows update degraded my BIOS version from 243 to 237. But when I try to upgrade both servers to version the update fails. First I got a warning like: CMOS Layout difference between System ROM and ROM file has detected. AFU recommand (sic) adding /C commands of your original input commands. Press "A" to accept AFU's recommendation. Press "F" to keep original input commands. And the update did not do anything. But now I get a message like: Reading flash ........ done Bootblock checksum ... ok Module checksums ..... bad Error: BIOS checksum error And the update stops. I tried some commands form this page: http://www.ami.com/support/downloads/txt/AFU_README.TXT But I don't try to much, the servers are still booting. Does anyone know how to update my servers to BIOS version 245? I used this version http://h20565.www2.hp.com/portal/site/hpsc/template.PAGE/public/psi/swdDetails/?sp4ts.oid=3884344&spf_p.tpst=swdMain&spf_p.prp_swdMain=wsrp-navigationalState%3Didx%253D%257CswItem%253DMTX_7bd12651ab954fdcb0d7ee164a%257CswEnvOID%253D54%257CitemLocale%253D%257CswLang%253D%257Cmode%253D%257Caction%253DdriverDocument&javax.portlet.begCacheTok=com.vignette.cachetoken&javax.portlet.endCacheTok=com.vignette.cachetoken and created a bootable USB stick sith HPQUSB.exe

    Read the article

  • Smart Array P400 - Accelerator Replacement Battery Failure

    - by inflammable
    TL;DR - Is the immediate failure of a replacement battery, for a failed battery, on a battery backed accelerator for a Smart Array P400 controller a common occurrence? Or are we likely to have an storage controller with an impending and critical fault? We have a slightly confusing situation with a Smart Array P400 storage controller with the 512mb battery backed accelerator addon on an HP DL380 server. The storage controller is (afaik) running the latest firmware and driver: Model: Smart Array P400 Controller Status: OK Firmware Version: 7.24 Serial Number: *snip* Rebuild Priority: Medium Expand Priority: Medium Number Of Ports: 2 The storage diagnostic (both on the both boot-up screen for the controller and within the 'Management Homepage' and the 'HP Array Diagnostic Utility') recently starting showing the following status a fault for the battery for the accelerator: Accelerator Status: Temporarily Disabled Error Code: Cache Disabled Low Batteries Serial Number: *snip* Total Memory: 524288 KB Read Cache: 25% Write Cache: 75% Battery Status: Failed Read Errors: 0 Write Errors: 0 We replaced the battery with a new unit (a visual inspection of the P400 card showing nothing unusual) and saw the same fault - but expected this to disappear over the course of a few hours/days as it charged. This didn't happy, and the fault status remains the same as above. Given the battery is a genuine part from HP, I wouldn't have expected a replacement battery to fail straight away, or to be dead-on-arrival (is that naivety on my part?). Is the immediate failure of a replacement battery, for a failed battery, on a battery backed accelerator a common occurrence? Or are we likely to have an storage controller with an impending and critical fault? Is there any diagnostic that could tell me more about the failed battery, without cracking the server open again? Many thanks!

    Read the article

  • HP SmartArray P400: How to repair failed logical drive?

    - by TegtmeierDE
    I have a HP Server with SmartArray P400 controller (incl. 256 MB Cache/Battery Backup) with a logicaldrive with replaced failed physicaldrive that does not rebuild. This is how it looked when I detected the error: ~# /usr/sbin/hpacucli ctrl slot=0 show config Smart Array P400 in Slot 0 (Embedded) (sn: XXXX) array A (SATA, Unused Space: 0 MB) logicaldrive 1 (698.6 GB, RAID 1, OK) physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SATA, 750 GB, OK) physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SATA, 750 GB, OK) array B (SATA, Unused Space: 0 MB) logicaldrive 2 (2.7 TB, RAID 5, Failed) physicaldrive 1I:1:3 (port 1I:box 1:bay 3, SATA, 750 GB, OK) physicaldrive 1I:1:4 (port 1I:box 1:bay 4, SATA, 750 GB, OK) physicaldrive 2I:1:5 (port 2I:box 1:bay 5, SATA, 750 GB, OK) physicaldrive 2I:1:6 (port 2I:box 1:bay 6, SATA, 750 GB, Failed) physicaldrive 2I:1:7 (port 2I:box 1:bay 7, SATA, 750 GB, OK) unassigned physicaldrive 2I:1:8 (port 2I:box 1:bay 8, SATA, 750 GB, OK) ~# I thought that I had drive 2I:1:8 configured as a spare for Array A and Array B, but it seems this was not the case :-(. I noticed the problem due to I/O errors on the host, even if only 1 physicaldrive of the RAID5 is failed. Does someone know why this could happen? The logicaldrive should go into "Degraded" mode but still be fully accessible from the host os!? I first tried to add the unassigned drive 2I:1:8 as a spare to logicaldrive 2, but this was not possible: ~# /usr/sbin/hpacucli ctrl slot=0 array B add spares=2I:1:8 Error: This operation is not supported with the current configuration. Use the "show" command on devices to show additional details about the configuration. ~# Interestingly it is possible to add the unassigned drive to the first array without problems. I thought maybe the controller put the array into "failed" state due to the missing spare and protects failed arrays from modification. So I tried was to reenable the logicaldrive (to add the spare afterwards): ~# /usr/sbin/hpacucli ctrl slot=0 ld 2 modify reenable Warning: Any previously existing data on the logical drive may not be valid or recoverable. Continue? (y/n) y Error: This operation is not supported with the current configuration. Use the "show" command on devices to show additional details about the configuration. ~# But as you can see, re-enabling the logicaldrive this was not possible. Now I replaced the failed drive by hotswapping it with the unassigned drive. The status now looks like this: ~# /usr/sbin/hpacucli ctrl slot=0 show config Smart Array P400 in Slot 0 (Embedded) (sn: XXXX) array A (SATA, Unused Space: 0 MB) logicaldrive 1 (698.6 GB, RAID 1, OK) physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SATA, 750 GB, OK) physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SATA, 750 GB, OK) array B (SATA, Unused Space: 0 MB) logicaldrive 2 (2.7 TB, RAID 5, Failed) physicaldrive 1I:1:3 (port 1I:box 1:bay 3, SATA, 750 GB, OK) physicaldrive 1I:1:4 (port 1I:box 1:bay 4, SATA, 750 GB, OK) physicaldrive 2I:1:5 (port 2I:box 1:bay 5, SATA, 750 GB, OK) physicaldrive 2I:1:6 (port 2I:box 1:bay 6, SATA, 750 GB, OK) physicaldrive 2I:1:7 (port 2I:box 1:bay 7, SATA, 750 GB, OK) ~# The logical drive is still not accessible. Why is it not rebuilding? What can I do? FYI, this is the configuration of my controller: ~# /usr/sbin/hpacucli ctrl slot=0 show Smart Array P400 in Slot 0 (Embedded) Bus Interface: PCI Slot: 0 Serial Number: XXXX Cache Serial Number: XXXX RAID 6 (ADG) Status: Enabled Controller Status: OK Chassis Slot: Hardware Revision: Rev E Firmware Version: 5.22 Rebuild Priority: Medium Expand Priority: Medium Surface Scan Delay: 15 secs Surface Analysis Inconsistency Notification: Disabled Raid1 Write Buffering: Disabled Post Prompt Timeout: 0 secs Cache Board Present: True Cache Status: OK Accelerator Ratio: 25% Read / 75% Write Drive Write Cache: Disabled Total Cache Size: 256 MB No-Battery Write Cache: Disabled Cache Backup Power Source: Batteries Battery/Capacitor Count: 1 Battery/Capacitor Status: OK SATA NCQ Supported: True ~# Thanks for you help in advance.

    Read the article

  • hp ilo "remote console undefined"

    - by javapowered
    After upgrading my server (HP DL360p Gen8) to the latest ILO 4.30 I have such error What should I do and how to fix my problem? I do not have physical access to my server and so now I have no access at all (I still have ILO with no remote console) I think probably I should use "back-up" copy of ilo if it stored on server... or should I reupload some another ILO version? upd I've noticed that undefined link is "https:///html/undefined", i think I can try "hack" and just type direct link to "remote" page, but i do not have an address. It should be something like "https:///html/remote.html" Probably someone, who has access to ilo, can give me a link?

    Read the article

  • HP SmartArray P212 with non HP disks, Insight Diagnostics error

    - by yonatan
    I have an ML110 G6 with a SmartArray P212 and two Seagate (non-HP) SAS disks in Raid 1. When I ran HP Insight Diagnostics I got some errors related to S.M.A.R.T. error testing and I would like to confirm that this is due to the controller not being able to query the drives as they are non-HP. I believe that the drives are not failing, but I want to be sure. Please have a look at these screenshots I took from the Insight Diagnostics report:

    Read the article

  • hp smart array lock up code 0x15, what is that? (or where can I get a list of descriptions of HP smart array controller lock up codes)

    - by user47650
    Hi, I've had a couple of Dl180 6g boxes hung over the last week, each have a P410 smart array controller. upon reboot the server has indicated that a controller failure event occurred and the previous lock up code was 0x15 - the server rebooted without issue. However there was nothing in the IML log, but the ADU report provided the following; Trap Address High Or Post Results Lockup Reason Or Post Error RIS Updates Or Post Error Detail Firmware Version Trap Address Low 0x8087 0x0015 0x0000033e 0x015e 0xd65c any suggestions on what that code is, my google fu failed. And hp support have not responded with any detail as yet.

    Read the article

  • How to get HP ASM to work under Xen Hypervisor?

    - by Dennis
    I have a HP DL560, currently running Debian Squeeze as dom0 on Xen Hypervisor, and the fans constantly run at 100%. In the past this wasn't a problem because I could install HP's ASM which includes fan management. However since I have installed a xen enabled kernel, the hp-health driver (the piece of ASM that controls the fans) won't start (at boot or manually). Anyone know of any way to make it work? (Or any other method of controlling the fans safely.) Note that the server has four i386 Xeon CPUs, each with its own fan, plus an extra case fan, and all of the fans can be doubled for redundancy. Also everything works fine under Squeeze without the xen-enabled kernel (can still boot the other one and hp-health loads fine on boot).

    Read the article