Search Results

Search found 2750 results on 110 pages for 'cc inc'.

Page 61/110 | < Previous Page | 57 58 59 60 61 62 63 64 65 66 67 68  | Next Page >

  • Linux Logitech QuickCam Pro 9000 - microphone issues

    - by drahnr
    I got a Logitech Quickcam Pro 9000, the cam itself is working as it honors the UVC spec. This fancy WebCam has a integrated mic which worked some time before but now, it does no more. (Note: I use pulseaudio as it is a USB Mic and I am not really keen on the hassle of ALSA setup) Things I check already are if it gets detected at all: $ lsusb |grep Logi Bus 002 Device 002: ID 046d:0809 Logitech, Inc. Webcam Pro 9000 is muted in alsa-mixer - not the case, volume at 100 pavucontrol shows it too, but no input level bar! On top of that, if I open the gnome3 (fallback mode) audio panel(from the desktop panel), and disabel/reenable it in the hardware tab, it works "for some time"... Any hints? Any ideas? I am really out options for now, and the fact it worked like 6 months ago (perfectly) makes it no better.

    Read the article

  • Redirect email based on Source IP / Hostname

    - by PostMan
    So, we have a situation where we would like to be able to redirect (ignoring original destination) emails coming through out exchange server (locally sent) to a different email address. The situation is as follows: Testing a new server, this hosts a lot of our custom applications / scheduled tasks (as does the production version of this server). Instead of changing config files / parameters for these applications we'd rather leave them as they are, as we want to be as close to production as possible, however we don't want the emails go to the staff they would normally go to, we'd rather they were sent to a test email address where we are able to confirm the results. The emails look exactly like the production emails (same from / to / cc / bcc) except their source, hence why we'd like to know if the ability to redirect based on hostname exists. Cheers.

    Read the article

  • Gathering IP's from a complicated log

    - by Harry
    I have a question regarding the use of some more advanced grep, awk, sed. I have a log file, for a proprietary MTA, that contains IP's in a string, delimited by [redacted]^~x.x.x.x^[redacted]. So far all of my grepping, awking, and sedding hasn't gotten me very far. This log file has 331520 lines in it. My goal was to simply grep out the ip's, then do a for loop with sed, to sed 's/$i/redacted'. I'm including a sample of one of the log entries. If you all have any idea, I would be greatly appreciative. Jun 4 15:21:52 host.name mta-name: 13388^~88/CC-04671-FCA0DCF4^~D^~<redactedmessageid>^~@^[email protected]^~redacted.hostname^~000.00.000.000^~port^~esmtp^~^~external_routing_nobounce^~0^~0.51^~subjectofmessage^~250 2.6.0 <redactedmessageid> [InternalId=2178458] Queued mail for delivery

    Read the article

  • Trouble joining Windows Server 2008 to Domain

    - by Jim R
    When I try to join my new server to my existing domain I get the following error: "An attempt to resolve the DNS name of a DC in the domain being joined has failed. Please verify this client is configured to reach a DNS server that can resove DNS names in the target domain." I have tried all of the following already: Successfully pinged the domain controller. Ping the new server from the domain controller by IP address and by DNS name. Ping the DC server from the new server by IP address and by DNS name. Changed the network to DHCP (it was originally static). No joy as static or DHCP. Turned off all firewall settings. Added the domain name to 'hosts' file. Added the server name of the primary domain controller to the 'hosts' file in the new server. Any ideas? Thanks in advance for any help! Jim Update: With help from J. Brian Kelly (Thanks) I have managed to narrow down the problem to a DNS issue. Specifically, UDP/53 packets are being sent (they are seen in Network Monitor), but are not getting to the DNS server. But, I do not yet know why. Update: The quested output from IPCONFIG for the HyperV host and the virtual machine. IPCONFIG from HyperV Server Windows IP Configuration Host Name . . . . . . . . . . . . : HYPER Primary Dns Suffix . . . . . . . : sfi-wfc.com Node Type . . . . . . . . . . . . : Hybrid IP Routing Enabled. . . . . . . . : No WINS Proxy Enabled. . . . . . . . : No DNS Suffix Search List. . . . . . : sfi-wfc.com Ethernet adapter Local Area Connection 4: Connection-specific DNS Suffix . : Description . . . . . . . . . . . : Primary Network Physical Address. . . . . . . . . : 00-30-48-CA-CC-7A DHCP Enabled. . . . . . . . . . . : No Autoconfiguration Enabled . . . . : Yes Link-local IPv6 Address . . . . . : fe80::cd16:3ac2:3d4f:e275%679(Preferred) IPv4 Address. . . . . . . . . . . : 192.168.100.1(Preferred) Subnet Mask . . . . . . . . . . . : 255.255.255.0 Default Gateway . . . . . . . . . : 192.168.100.10 DHCPv6 IAID . . . . . . . . . . . : -1476382648 DHCPv6 Client DUID. . . . . . . . : 00-01-00-01-12-10-20-E9-00-30-48-CA-CC-7A DNS Servers . . . . . . . . . . . : 192.168.100.5 NetBIOS over Tcpip. . . . . . . . : Enabled Ethernet adapter Local Area Connection 3: Media State . . . . . . . . . . . : Media disconnected Connection-specific DNS Suffix . : sfi Description . . . . . . . . . . . : Intel(R) 82576 Gigabit Dual Port Network Connection #2 Physical Address. . . . . . . . . : 00-30-48-CA-CC-7B DHCP Enabled. . . . . . . . . . . : Yes Autoconfiguration Enabled . . . . : Yes IPCONFIG from Virtual Machine Windows IP Configuration Host Name . . . . . . . . . . . . : DB Primary Dns Suffix . . . . . . . : Node Type . . . . . . . . . . . . : Hybrid IP Routing Enabled. . . . . . . . : No WINS Proxy Enabled. . . . . . . . : No DNS Suffix Search List. . . . . . : sfi Ethernet adapter Local Area Connection 2: Connection-specific DNS Suffix . : sfi Description . . . . . . . . . . . : Microsoft Virtual Machine Bus Network Adapter Physical Address. . . . . . . . . : 00-15-5D-66-03-02 DHCP Enabled. . . . . . . . . . . : Yes Autoconfiguration Enabled . . . . : Yes IPv4 Address. . . . . . . . . . . : 192.168.100.128(Preferred) Subnet Mask . . . . . . . . . . . : 255.255.255.0 Lease Obtained. . . . . . . . . . : Saturday, August 29, 2009 10:44:45 AM Lease Expires . . . . . . . . . . : Tuesday, September 01, 2009 3:08:33 PM Default Gateway . . . . . . . . . : 192.168.100.10 DHCP Server . . . . . . . . . . . : 192.168.100.5 DNS Servers . . . . . . . . . . . : 192.168.102.5 Primary WINS Server . . . . . . . : 192.168.100.5 NetBIOS over Tcpip. . . . . . . . : Enabled Tunnel adapter Local Area Connection* 8: Media State . . . . . . . . . . . : Media disconnected Connection-specific DNS Suffix . : sfi Description . . . . . . . . . . . : isatap.sfi Physical Address. . . . . . . . . : 00-00-00-00-00-00-00-E0 DHCP Enabled. . . . . . . . . . . : No Autoconfiguration Enabled . . . . : Yes Tunnel adapter Local Area Connection* 9: Media State . . . . . . . . . . . : Media disconnected Connection-specific DNS Suffix . : Description . . . . . . . . . . . : Teredo Tunneling Pseudo-Interface Physical Address. . . . . . . . . : 02-00-54-55-4E-01 DHCP Enabled. . . . . . . . . . . : No Autoconfiguration Enabled . . . . : Yes

    Read the article

  • Xen 4.2 on CentOs 6.3 : can't compile a libvirt 0.9.10 xen-activated?

    - by Frederic
    I followed that tutorial for Xen 4.2 on CentOs 6.3. http://www.howtoforge.com/virtualization-with-xen-on-centos-6.3-x86_64-paravirtualization-and-hardware-virtualization When building a new libvirt package with rpmbuild -bb libvirt.spec I get that error : CC libvirt_driver_libxl_la-libxl_conf.lo In file included from libxl/libxl_conf.c:43: libxl/libxl_conf.h:61: error: field 'ctx' has incomplete type libxl/libxl_conf.h:80: error: field 'ctx' has incomplete type libxl/libxl_conf.h:81: error: expected specifier-qualifier-list before 'libxl_waiter' libxl/libxl_conf.c: In function 'libxlMakeDomCreateInfo': libxl/libxl_conf.c:365: warning: implicit declaration of function 'libxl_init_create_info' [-Wimplicit-function-declaration] libxl/libxl_conf.c:365: warning: nested extern declaration of 'libxl_init_create_info' [-Wnested-externs] libxl/libxl_conf.c:367: error: 'libxl_domain_create_info' has no member named 'hvm' libxl/libxl_conf.c:383: warning: implicit declaration of function 'libxl_domain_create_info_destroy' [-Wimplicit-function-declaration] libxl/libxl_conf.c:383: warning: nested extern declaration of 'libxl_domain_create_info_destroy' [-Wnested-externs] libxl/libxl_conf.c: In function 'libxlMakeDomBuildInfo': libxl/libxl_conf.c:406: warning: implicit declaration of function 'libxl_init_build_info' [-Wimplicit-function-declaration] libxl/libxl_conf.c:406: warning: nested extern declaration of 'libxl_init_build_info' [-Wnested-externs] libxl/libxl_conf.c:408: error: 'libxl_domain_build_info' has no member named 'hvm' [...] Do you know what I need to install or change to pass that step?

    Read the article

  • How can I have APF block script kiddies that mod_security detects?

    - by Gaia
    In one of the vhosts' error_log I found thousands of lines like these, all from the same IP: [Mon Apr 19 08:15:59 2010] [error] [client 61.147.67.206] mod_security: Access denied with code 403. Pattern match "(chr|fwrite|fopen|system|e?chr|passthru|popen|proc_open|shell_exec|exec|proc_nice|proc_terminate|proc_get_status|proc_close|pfsockopen|leak|apache_child_terminate|posix_kill|posix_mkfifo|posix_setpgid|posix_setsid|posix_setuid|phpinfo)\\\\(.*\\\\)\\\\;" at THE_REQUEST [id "330001"] [rev "1"] [msg "Generic PHP exploit pattern denied"] [severity "CRITICAL"] [hostname "x.x.x.x"] [uri "//webmail/config.inc.php?p=phpinfo();"] Given how obvious the situation is, how come mod_security isnt automatically adding at least that IP to deny rules? There is no way someone hasnt thought of this before...

    Read the article

  • Convert audio file to FLAC with ffmpeg?

    - by elpsk
    can I convert one of this format to compatible 16000.0 Sample Rate FLAC file? kAudioFormatLinearPCM = 'lpcm', kAudioFormatAppleIMA4 = 'ima4', kAudioFormatMPEG4AAC = 'aac ', kAudioFormatMACE3 = 'MAC3', kAudioFormatMACE6 = 'MAC6', kAudioFormatULaw = 'ulaw', kAudioFormatALaw = 'alaw', kAudioFormatMPEGLayer1 = '.mp1', kAudioFormatMPEGLayer2 = '.mp2', kAudioFormatMPEGLayer3 = '.mp3', kAudioFormatAppleLossless = 'alac' I tried using ffmpeg ffmpeg -i audio.xxx -acodec flac audio.flac but result is FFmpeg version CVS, Copyright (c) 2000-2004 Fabrice Bellard Mac OSX universal build for ffmpegX configuration: --enable-memalign-hack --enable-mp3lame --enable-gpl --disable-vhook --disable-ffplay --disable-ffserver --enable-a52 --enable-xvid --enable-faac --enable-faad --enable-amr_nb --enable-amr_wb --enable-pthreads --enable-x264 libavutil version: 49.0.0 libavcodec version: 51.9.0 libavformat version: 50.4.0 built on Apr 15 2006 04:58:19, gcc: 4.0.1 (Apple Computer, Inc. build 5250) Input #0, wsaud, from 'audio.alac': Duration: 00:00:03.8, start: 0.000000, bitrate: 199 kb/s Stream #0.0: Audio: adpcm_ima_ws, 24931 Hz, stereo, 199 kb/s Unable for find a suitable output format for 'audio.flac' I also installed flac codec for mac, but nothing... I tried also use convtoflac.sh (from http://legroom.net/software/convtoflac) but result is similar. Any idea to convert in flac?

    Read the article

  • Postfix tutorial inconsistency

    - by Desmond Hume
    I'm following this tutorial to setup a Postfix/Dovecot mail server with Postfix Admin as a web front end. As regards directory structure for virtual mail users, the author of the tutorial writes: Virtual mail users are those that do not exist as Unix system users. They thus don't use the standard Unix methods of authentication or mail delivery and don't have home directories. That is how we are managing things here: mail users are defined in the database created by Postfix Admin rather than existing as system users. Mail will be kept in subfolders per domain and account under /var/vmail - e.g. [email protected] will have a mail directory of /var/vmail/example.com/me. But when he gives instructions about configuring Postfix Admin, he suggests this to be contained by Postfix Admin's config.inc.php: // Mailboxes // If you want to store the mailboxes per domain set this to 'YES'. // Examples: // YES: /usr/local/virtual/domain.tld/[email protected] // NO: /usr/local/virtual/[email protected] $CONF['domain_path'] = 'NO'; Is there an inconsistency?

    Read the article

  • CentOS PAM+LDAP login and host attribute

    - by pianisteg
    My system is CentOS 6.3, openldap is configured well, PAM authorization works fine. But after turning pam_check_host_attr to yes, all LDAP-auths fail with message "Access denied for this host". hostname on the server returns correct value, the same value is listed in user's profile. "pam_check_host_attr no" works fine and allows everyone with correct uid/password a piece of /var/log/secure: Sep 26 05:33:01 ldap sshd[1588]: pam_unix(sshd:auth): authentication failure; logname= uid=0 euid=0 tty=ssh ruser= rhost=my-host user=my-username Sep 26 05:33:01 ldap sshd[1588]: Failed password for my-username from 77.AA.BB.CC port 58528 ssh2 Sep 26 05:33:01 ldap sshd[1589]: fatal: Access denied for user my-username by PAM account configuration Another two servers (CentOS 5.7 Debian) authorizes on this LDAP server correctly. Even with pam_check_host_attr yes! I didn't edit /etc/security/access.conf, it is empty, only default comments. I don't know what to do! How to fix this?

    Read the article

  • re-point LM to a new vCenter (share same database)

    - by CapiZikus
    1) I'm planning to create a new vCenter server which database point to the same db as current vCenter (the one LM pointing to atm), Then I'm planning to repoint the LM to a new vCenter, ( the new one will see the same esx host, datastore, etc) Is LM will be okay if I do this? 2) The currect VC is a dediated server and a new vCenter will be VM, the current vCenter has database installed on local machine (inc update manager as well) I'm planning to move the local db to cluster db then point the current vCenter to this new cluster and make sure everything is working before promote a new one. Update manager will also has it own VM and point to a new db cluster. Is anythingelse I miss out or need to pay more attention on? thanks

    Read the article

  • BSOD 0x000000f4(Probably caused by : wininit.exe)

    - by vacuum
    I have BSOD with 0x000000f4 code. It appears when system is not loaded at all. No new hardware where intalled. Only nvidia drivers where updated 3 days ago and they are up to date for now(version 296.10). System Health Report(perfmon /report) shows nothing interesting(only complained on disabled UAC) System is on SSD disk(WDC SSC-D0064SC-2100 B) Dump Spec: OS Name Microsoft Windows 7 Ultimate Version 6.1.7601 Service Pack 1 Build 7601 System Manufacturer Gigabyte Technology Co., Ltd. System Model P31-DS3L System Type x64-based PC Processor Intel(R) Core(TM)2 Duo CPU E7200 @ 2.53GHz, 2534 Mhz, 2 Core(s), 2 Logical Processor(s) BIOS Version/Date Award Software International, Inc. F9, 10.07.2008 Any suggestions?

    Read the article

  • bash starts replacing the characters on the current line insead of moving over to the next line

    - by Lazer
    I use bash shell $ bash --version GNU bash, version 3.2.25(1)-release (x86_64-redhat-linux-gnu) Copyright (C) 2005 Free Software Foundation, Inc. $ Sometimes, when typing a command on the prompt that is pretty lengthy and does not fit in the current line, instead of displaying the extra characters on the next line, bash starts again on the current line.. replacing the characters that were there and making a mess. what should happen : |---------------------------------------------| | $ my big long command takes a lot of argumen| | s and does not fit in a single line | | | |---------------------------------------------| what happens instead : |---------------------------------------------| | s and does not fit in a single linef argumen| | | | | |---------------------------------------------| The issue is intemittent If I resize my shell window to really small width, normal behaviour is restored Does anyone have any idea what is happening here? $ echo $TERM xterm $ echo $PS1 \[\e[30m\][\t]\[\e[0m\]\[\e]0;\w\a\]\[\e[30m\][\W]$ $

    Read the article

  • Non-Registry Fix for Secondary Mailboxes Sent Items

    - by Jai Kang
    There is a known issue with Outlook and Exchange where "secondary" mailboxes which are mounted in the same profile, e.g. "John Doe" + CorpMailbox1, CorpMailbox2, CorpMailbox3 will place "sent items" from the secondary mailboxes (e.g. CorpMailbox1) in the user's (e.g. "John Doe") Sent Items folder. There is a registry value (something like DelegateSentItems) to semi-fix this, but I'm looking for an Exchange-side solution. It seems like, at some point, an admin made CC rules to fix this, and for the mailboxes where I see a BCC rule: any item sent to [address] BCC to [address]. The behavior "fixes" the issue, but when I duplicate this work-around for new shared mailboxes, the email ends up in the Inbox and not the Sent Items for the shared mailbox. I don't believe there is any outlook/client-side shenanigans going on, as the intended behavior for the older mailboxes works for new PCs/Users (new imagse) without any Outlook Mailbox Rules.

    Read the article

  • OpenGL support no longer available

    - by Aznfin
    I've been using OpenGL hardware acceleration in programs such as Adobe Photoshop CS4 and Adobe After Effects CS4. I've noticed that recently the options for OpenGL previews are disabled because my graphics card seems to not support OpenGL. But that doesn't make any sense whatsoever. I know for a fact that my graphics card does have support for OpenGL and it worked before. I checked for driver updates just the other day. Anybody know what's going on? Info: Operating System: Windows 7 Home Premium 64-bit GPU: ATI Radeon HD 3200 Driver Packaging Version: 8.69-091211a-094296C-ATI Catalyst™ Version: 09.12 Provider: ATI Technologies Inc. 2D Driver Version: 8.01.01.994 2D Driver File Path: /REGISTRY/MACHINE/SYSTEM/ControlSet001/Control/CLASS /{4D36E968-E325-11CE-BFC1-08002BE10318}/0000 Direct3D Version: 8.14.10.0723 OpenGL Version: 6.14.10.9252 Catalyst™ Control Center Version: 2009.1211.1547.28237

    Read the article

  • vmware linux headers not found for ubuntu 10.10 ?

    - by Tumbleweed
    I've installed Vmware 6.5 on Ubuntu 10.10... when I start vmware player/workstation its asking for linux kernel header for some compilation but I'm not able to find the appropriate package, see the Image below.... Update after running following commands sudo -s cd /lib/modules/$(uname -r)/build/include/linux ln -s ../generated/utsrelease.h ln -s ../generated/autoconf.h Error has been changed like below.... ERROR: modinfo: could not find module vmmon ERROR: modinfo: could not find module vmnet ERROR: modinfo: could not find module vmblock ERROR: modinfo: could not find module vmci ERROR: modinfo: could not find module vsock Using 2.6.x kernel build system. make: Entering directory /tmp/vmware-root/modules/vmmon-only' make -C /lib/modules/2.6.35-22-generic/build/include/.. SUBDIRS=$PWD SRCROOT=$PWD/. modules make[1]: Entering directory/usr/src/linux-headers-2.6.35-22-generic' CC [M] /tmp/vmware-root/modules/vmmon-only/linux/driver.o In file included from /tmp/vmware-root/modules/vmmon-only/linux/driver.c:31: /tmp/vmware-root/modules/vmmon-only/./include/compat_wait.h:78: error: conflicting types for ‘poll_initwait’ include/linux/poll.h:72: note: previous declaration of ‘poll_initwait’ was here

    Read the article

  • How to install pecl uploadprogress on Debian Lenny

    - by kidrobot
    I am getting this output/error for # pecl install uploadprogress downloading uploadprogress-1.0.1.tgz ... Starting to download uploadprogress-1.0.1.tgz (8,536 bytes) .....done: 8,536 bytes 4 source files, building running: phpize Configuring for: PHP Api Version: 20041225 Zend Module Api No: 20060613 Zend Extension Api No: 220060519 building in /var/tmp/pear-build-root/uploadprogress-1.0.1 running: /tmp/pear/temp/uploadprogress/configure checking for grep that handles long lines and -e... /bin/grep checking for egrep... /bin/grep -E checking for a sed that does not truncate output... /bin/sed checking for gcc... no checking for cc... no checking for cl.exe... no configure: error: no acceptable C compiler found in $PATH See `config.log' for more details. ERROR: `/tmp/pear/temp/uploadprogress/configure' failed php-pear is installed. I'm stumped.

    Read the article

  • Is there a way to determine which service does an outgoing connection?

    - by fluxtendu
    I'm redoing my firewall configuration with more restrictive policies and I would like to determine the provenance (and/or destination) of some outgoing connections. I have an issue because they come from svchost.exe and go to web content/application delivery providers - or similar: 5 IP in range: 82.96.58.0 - 82.96.58.255 --> Akamai Technologies akamaitechnologies.com 3 IP in range: 93.150.110.0 - 93.158.111.255 --> Akamai Technologies akamaitechnologies.com 2 IP in range: 87.248.194.0 - 87.248.223.255 --> LLNW Europe 2 llnw.net 205.234.175.175 --> CacheNetworks, Inc. cachefly.net 188.121.36.239 --> Go Daddy Netherlands B.V. secureserver.net So is it possible to know which service does a particular connection? Or what's your recommendation about the rules applied to these ones? (Comodo Firewall & Windows 7)

    Read the article

  • HP LaserJet 1320 printing black boxes instead of text

    - by David Gard
    I have an HP LaserJet 1320, running off of the HP PCL5 64-bit Universal Driver (Windows 7 Professional, 64-bit). When printing, anything other than body text is blacked out. I.e. on an email, where the 'To...', 'From...', 'CC...' and 'Subect' are usually shown at the top, there is just a black box. And on Word documents, anything to do with Track Changes is also blacked out. I have tried restarting the Print Spooler, and reinstalling the printer, but this does not help. Does anybody know why this is happening?

    Read the article

  • Improve my System, Need some advice/suggestion

    - by Pennf0lio
    Processor: 2.40 gigahertz Intel Core2 Duo Board: ASUSTeK Computer INC. P5B-MX Memory: 2 Gb VideoCard: NVIDIA GeForce 7300 GT HDD: 80GB + 250GB both IDE Operating System: Windows 7 32bit Please give me some advice what to improve in my System. I mainly used it for Graphic Design (eg, Photoshop, Cinema4d, Illustrator, Flash). I was planning to increase my Memory adding 2 GB more, Pushing it to something like 4GB in total. But just found out that recently that I already have 2x2GB installed and should be 4GB in total. When I looked at the properties of my computer, It said "Installed Memory 2GB". I wonder why is that happening? Is the other ram broken?.. I never the computer casing since I bought. so I didn't realize that I already have 2 x 2gb ram. what can you advice. Thanks!

    Read the article

  • Hypertransport sync flood error

    - by Carl B
    What is it? And what causes it? Is it only for uncorrectable DIMM Errors(Troubleshooting DIMM errors)? When an UCE occurs, the memory controller causes an immediate reboot of the system. During reboot, the BIOS checks the Machine Check registers and determines that the previous reboot was due to an UCE, then reports this in POST after the memtest stage: A Hypertransport Sync Flood occurred on last boot 3 BIOS reports this event in the service processor’s system event log (SEL) as shown in the sample IPMItool output There are what seems to be some suggested answers to include Bad Caps Bios verisons (happens in one version not the other) Graphics card issues Lack of power to the CPU The list of possible generators seems to target everything but the computer case. System Specs: Windows Home Premium 64 Motherboard - MSI790FX-GD70 (MS7577) / Bios v 1.9 (American Megatrensa Inc) Ram - Patriot G Series ‘Sector 5’ Edition 4GB DDR3 1600 CPU - AMD Phenom II X2 555 Black Edition Callisto 3.2GHz Socket AM3 80W (Note: unlocked 2 cores CPU Z ids it as phenom II x4 B55) Graphics - 2 x Radeon 5750 in crossfire PSU - ABS 900w HDDs - 2 Seagate 1.5 TB Sata SSD - 1 OCZ 120 GB Vertex Plus R2

    Read the article

  • Solaris syslog.conf. What are root and operator?

    - by cjavapro
    In /etc/syslog.conf #ident "@(#)syslog.conf 1.5 98/12/14 SMI" /* SunOS 5.0 */ # # Copyright (c) 1991-1998 by Sun Microsystems, Inc. # All rights reserved. # # syslog configuration file. # # This file is processed by m4 so be careful to quote (`') names # that match m4 reserved words. Also, within ifdef's, arguments # containing commas must be quoted. # *.err;kern.notice;auth.notice /dev/sysmsg *.err;kern.debug;daemon.notice;mail.crit /var/adm/messages *.alert;kern.err;daemon.err operator *.alert root *.emerg * # if a non-loghost machine chooses to have authentication messages # sent to the loghost machine, un-comment out the following line: #auth.notice ifdef(`LOGHOST', /var/log/authlog, @loghost) mail.debug ifdef(`LOGHOST', /var/log/syslog, @loghost) # # non-loghost machines will use the following lines to cause "user" # log messages to be logged locally. # ifdef(`LOGHOST', , user.err /dev/sysmsg user.err /var/adm/messages user.alert `root, operator' user.emerg * ) I googled some and it seems that root and operator mean email to root and to operator. Is this correct?

    Read the article

  • Why does 1GBit card have output limited to 80 MiB ?

    - by Gallus
    I'm trying to utilize maximal bandwidth provided by my 1GiB network card, but it's always limited to 80MiB (real megabytes). What can be the reason? Card description (lshw output): description: Ethernet interface product: DGE-530T Gigabit Ethernet Adapter (rev 11) vendor: D-Link System Inc physical id: 0 bus info: pci@0000:03:00.0 logical name: eth1 version: 11 serial: 00:22:b0:68:70:41 size: 1GB/s capacity: 1GB/s width: 32 bits clock: 66MHz capabilities: pm vpd bus_master cap_list rom ethernet physical tp 10bt 10bt-fd 100bt 100bt-fd 1000bt 1000bt-fd autonegotiation The card is placed in following PCI slot: *-pci:2 description: PCI bridge product: 82801 PCI Bridge vendor: Intel Corporation physical id: 1e bus info: pci@0000:00:1e.0 version: 92 width: 32 bits clock: 33MHz capabilities: pci subtractive_decode bus_master cap_list The PCI isn't any PCI Express right? It's a legacy PCI slot? So maybe this is the reason? OS is a linux.

    Read the article

  • Drupal + Lighttpd: enabling clean urls (rewriting)

    - by Patrick
    I'm emulating Ubuntu on my mac, and I use it as a server. I've installed lighttpd + Drupal and the following configuration section requires a domain name in order to make clean urls to work. Since I'm using a local server I don't have a domain name and I was wondering how to make it work given the fact the ip of the local machine is usually changing. thanks $HTTP["host"] =~ "(^|\.)mywebsite\.com" { server.document-root = "/var/www/sites/mywebsite" server.errorlog = "/var/log/lighttpd/mywebsite/error.log" server.name = "mywebsite.com" accesslog.filename = "/var/log/lighttpd/mywebsite/access.log" include_shell "./drupal-lua-conf.sh mywebsite.com" url.access-deny += ( "~", ".inc", ".engine", ".install", ".info", ".module", ".sh", "sql", ".theme", ".tpl.php", ".xtmpl", "Entries", "Repository", "Root" ) # "Fix" for Drupal SA-2006-006, requires lighttpd 1.4.13 or above # Only serve .php files of the drupal base directory $HTTP["url"] =~ "^/.*/.*\.php$" { fastcgi.server = () url.access-deny = ("") } magnet.attract-physical-path-to = ("/etc/lighttpd/drupal-lua-scripts/p-.lua") }

    Read the article

  • Is it possible to control my CPU frequency?

    - by Tim
    My laptop's CPU Type is: Mobile AMD Turion 64 ML-30, 1600 MHz (8 x 200) I was wondering how to find out if its CPU frequency is controllable? What softwares or other ways can control my CPU frequency? My OSes are Windows XP and Ubuntu. Can I control CPU frequency so that the CPU temperature can be controlled not to exceed some temperature? Thanks and regards! More information: My laptop is Acer Aspire 5000. Its motherboard is reported by Speccy as: Manufacturer: Acer, Inc. Model: Lugano M Version: Not Applicable Chipset Vendor: SiS Chipset Model: 760GX Chipset Revision: 03 Southbridge Vendor: SiS Southbridge Model: LPC Bridge Southbridge Revision: 25 BIOS Brand: Acer Version: 3A19 Date: 05/17/05

    Read the article

  • Battery backed write cache behavior upon disk change

    - by Halfgaar
    We use 3ware Inc 9650SE SATA-II RAID PCIe RAID controllers with battery backed write cache. Our spare hardware has the same controller. I was wondering; are these controllers smart enough not to sync the cache when the disks have been changed? For example, if I deploy one of those spare machines by putting in the disks of another machine and that spare machine still has pending writes, will it be smart enough not to perform those writes on the replaced array? Edit: my scenario is not really made clear, so let me give an example: server1 goes down because of power supply failure. I put the disks in server2 and start. I repair server1 I put the disks back from server2 in server1 (it's not relevant right now that in reality I would probably keep server2 running). If server1 doesn't have safeguards, it will write to the array, thinking it's simply powering up again, corrupting it.

    Read the article

< Previous Page | 57 58 59 60 61 62 63 64 65 66 67 68  | Next Page >