  • Photo Management Software for OS X That Supports Multiple Library Locations

    - by Lance Rushing
    I'm looking at the possibility of changing our photo management software. Thinking about Aperture or Lightroom. And want to know if either supports: Having folders/libraries on separate harddrives/Volumes. Tolerates having network folders occasionally connected Snappy interface A solid enough piece of software as not to crash or behave weirdly. [ so the wife doesn't get stuck and have to call me ;) ] Background The wife is photographer and I'm the computer programmer. Our current setup is Picasa, with a "Recent/Working" folder on the local iMac harddrive, and "Archive" folders on NFS mounted Linux Server, Raid 5, for redundant and extra storage capacity. (the Linux server also syncs with Amazon's EC2) Picasa is doing OK, but I get annoyed when it doesn't do behave properly. Usually around issues when the Linux disk isn't mounted. And overall, I wish Picasa seemed a little more polished and snappier. Thanks, Lance

    Read the article

  • Will this increase my VPS failing rate ?

    - by Spencer Lim
    Will this increase my Virtual private Server failing rate if i :- install Microsoft Window Server 2008 Enterprise install SQL server enterprise 2008 install IIS 7.5 install ASP.Net Mvc 2 install Microsoft Exchange install Team foundation server on one mini VPS with specification of DELL Poweredge R710 shared plan DDR3 ECC RAMs 16GB and -- 1GB for this VPS using DELL PERC 6i raid controller (this thing alone about 1.5k-2k) and the SAS HDD (15K RPM) (146GB) -- 33GB to this VPS each hdd is freaking fast over 300MB read / write possible with proper tuning the motherboard is a DELL and it has twin redundant PSU (870watt 85%eff) its running on Intel Xeon 5502 (Quad Core) x2 so about 8 physical proc (fairly share) is there any ruler for this about one VPS can only install what what what service ? Thx for reply

    Read the article

  • Change the location of the System Temp directory on Windows 2003 Server

    - by skylarking
    In order to update an application on a Windows 2003 Server box, the application calls for 2.0 GB of free space in the System's Temp directory. The OS is on C:\ , and there is only 1 GB of free space there.... The server has a RAID configuration for its data on the system's E:\ . There is over 100GB of free space on E:\ . When I did a set tmp I found that the system's TEMP directory is not surprisingly located on C:\ .... TMP = C:\DOCUME~1\ADMINI~1.DES\LOCALS~1\Temp I assume it is possible to change the System Temp directory to the be located on E:\ ? How is this done, where's a good place to stick it, and is it safe to do this ?

    Read the article

  • How to set up Dell OMSA tools on Debian 6 (Squeeze) (PE2950)

    - by javano
    I assume I have set up them up incorrectly or am missing a library or dependency. When I log into the OMSA web interface I can't see anything Also, omreport tells me nothing; root@box:~# omreport storage controller No controllers found I assume these two will use the same source of information so what ever is wrong will fix them both. I set up OMSA as per these instructions. Also I have compiled MegaCLI (as this is a PowerEdge 2950 with a Perc 6/i controller) and I have used that to update the RAID firmware, so that works, but the Dell tools aren't. What have I missed during set up? root@kvm1:~# cat /etc/issue Debian GNU/Linux 6.0 \n \l root@kvm1:~# uname -a Linux kvm1.mivoice.cust.vostron.net 3.4.9 #1 SMP Wed Aug 22 19:08:46 BST 2012 x86_64 GNU/Linux

    Read the article

  • How to stop a Linux LVM volume group?

    - by thkala
    I am currently dealing with a multiple disk failure on a Linux LVM Volume Group that is backed up by a RAID-5 md device. One disk has been taken out completely and another one is showing a limited number of corrupt sectors, due to what seems to have been a misbehaving power supply. The problem is that once an I/O error hits, md takes the array down, since it does not have enough devices for it to be operational. Where md the only one involved, I could mdadm --stop the array and then recreate it to get all devices active again. Unfortunately, the array is a PV in an LVM volume group and I cannot seem to get the kernel to release it. vgchange -an does not seem to do anything, bar spew out a couple of I/O errors. I am obviously missing something, but how in the name of -insert-favorite-deity- do I get LVM to release the underlying PV without rebooting the server?

    Read the article

  • Using a non-validated SED on a Dell R720

    - by a coder
    We were given a Dell R720 a couple years ago, and the machine currently has standard 300GB 3.5" SAS 15k drives. Our RAID controller is a Perc H710. We need to update our disks to FIPS 140-2 certified SED. According to Dell, they have only one tested/validated FIPS SED for this machine/controller, but it is a 7200rpm 3.5" unit. I'm showing that Dell offers a 600GB 15k FIPS SED in 3.5" configuration (Dell part number 342-0605), but they say they haven't validated or tested to know if it works. They informed us that we would not void our warranty in using this non-validated drive. How likely is it that our R720 with H710 controller will work with the non-validated drive? Are there significant differences in how drive manufacturers build SED that would prevent them from working consistently across different controllers?

    Read the article

  • Linux stretch cluster: MD replication, DRBD or Veritas?

    - by PieterB
    For the moment there's a lot of choices for setting up a Linux cluster. For cluster manager: you can use Red Hat Cluster manager, Pacemaker or Veritas Cluster Server. The first one has the most momentum, the second one comes by default with RH subscriptions and the last one is very expensive and has a very good reputation ;-) For storage: - You can replicate LUN's using software raid / md device - You can use the network using DRBD replication, which offers a bit more flexibility - You can use Veritas Storage Foundation technology to talk to your SANs replication technology. Anyone has any recommandations or experience with these technologies?

    Read the article

  • why is iometer performance slower after first run?

    - by Dan
    I'm doing some benchmarking with IOMeter, and I'm seeing a consistent and susbtantial drop-off in performance after running the first test. These drop-offs are about the same on the three systems I've tested on, which makes me think it's a configuration setting, or just a fact of life about using IOMeter. For example, one system (local RAID 10) went from 388 I/Os per second the first run, to about 211 I/Os per second on every run after that. Everything else about the test was identical, and I also bounced the machine in between runs. So, is this expected behavior, or am I missing something?

    Read the article

  • EBS+RAID10+XFS slower than EBS+RAID10+EXT3 using MySQL?

    - by Johann Tagle
    We're currently using EC2 with 16 EBS volumes in RAID10 configuration for our MySQL data. I know some people don't recommend to put EBS volumes to RAID but that's not what I'm concerned about at the moment. Current format is ext3, but we're experimenting with moving to xfs, given many reports that it is faster. However, we're actually experiencing a performance degradation when the partition was converted to xfs - a benchmark run with inserts, updates, selects and deletes was more than 10 seconds slower using xfs. Any idea what could be the problem? Below is the fstab entry (really only changed ext3 to xfs). Database tables are innodb and we are using innodb_file_per_table. /dev/mapper/vg_data-lv_data /data xfs noatime 0 0 Thanks.

    Read the article

  • setting up/installing/configuring nginx LEMP stack on fresh VPS server

    - by Grant Tailor
    I need some help in settingup/installing and configuring nginx LEMP stack on a fresh new VPS I have. The specs of the CentOS 5.7 VPS are 2GB DDR3 ECC RAM(4GB burst), 1 core 1.5Ghz(3Ghz burst) and 100GB RAID 10 storage, unmetered bandwidth @ 100Mpbs all for a whopping $25/month(unbeatable, yeah I know :) Anyways I have followed this LEMP (will also need MySQL and PHP) stack guide on linode http://library.linode.com/lemp-guides/centos-5 but basically what I want is to be able to host multiple website on this webserver after everything is setup. I am used to using DirectAdmin control panel on other server and want to have things setup so I can host multiple websites - mostly wordpress and drupal themes. Lets say 10 websites on this nginx web server. So can someone please help me on what I need to do to take "full" advantage of nginx power and performance, while been able to easily manage these multiple websites (wordpress and drupal themes)?

    Read the article

  • Should I disable write caching on my Windows 2008 VM?

    - by javano
    I have a Windows Server 2008 x64 Standard virtual machine that runs on a machine with a hardware RAID controller, a Perc 6/i, which has a battery on-board. Doing everything I can for additional performance, I think I should disable this. Is this very dangerous though? My understand is that Battery Backed Write Caching gives a performance boost to the host OS, telling it the write was complete when they are still sitting in flash waiting to be written. However, I can't see how it would be detrimental to performance, but is there a gain (even if marginal) to enabling it / disabling it? P.s. There machine has a backup power. Here is a screen shot for clarification:

    Read the article

  • Linux stretch cluster: MD replication, DRBD or Veritas?

    - by PieterB
    For the moment there's a lot of choices for setting up a Linux cluster. For cluster manager: you can use Red Hat Cluster manager, Pacemaker or Veritas Cluster Server. The first one has the most momentum, the second one comes by default with RH subscriptions and the last one is very expensive and has a very good reputation ;-) For storage: - You can replicate LUN's using software raid / md device - You can use the network using DRBD replication, which offers a bit more flexibility - You can use Veritas Storage Foundation technology to talk to your SANs replication technology. Anyone has any recommandations or experience with these technologies?

    Read the article

  • 284 GiB of data, 217.4 GiB of space

    - by Malfist
    I want to reinstall my OS, but I don't have the hard drive space to backup any more (I have a RAID 1 array, so I haven't done it for a while). In my /home I have 284.8 GiB of data, and I have a spare 250 GB (or 217.4 GiB) hard drive that I've been using for backup. What type of compression algorithm (if any) is capable of this type of compression? I don't care about the time, I have a quad core though, so something that utilizes all 4 cores would be great. I have tried 7zip with no success. Ran on one core for two days and failed because of lack of space. Any ideas?

    Read the article

  • Storage product testing

    - by wildchild
    hello, I know this is out of place (being an active member here i am coming for the help from seniors) ,but i need some information regarding storage testing ,testing of Raid arrays, SCSI, SAS ,SATA and also test carried out on fabric manager(Cisco MDS series switches). I am aware that this is an administrative forum and i would really appreciate if you could direct me to the correct forum ar links where i can learn things . @ moderators-Sorry for posting at the wrong place,i would be deleting this as soon as i get the help. Thanks !

    Read the article

  • Is Dell's server software bundle necessary? (Poweredge 2950 in my case)

    - by bwerks
    Hi all, Dell includes a fair amount of software with its servers, but I'm having a hard time determining from the documentation what each of them does, and whether or not I should install it. Dell's support site (unless I'm doing it wrong) seems fairly opaque to me and its offerings fairly unstandardized in terms of their usage, so if possible I'd like to stray away from them. Specifically, I'm curious if any of the features offered are duplicated in something like Microsoft System Center. For additional background information, I'm working with a Poweredge 2950 that was just rebuilt with an expanded raid-6, but initially I just installed Server 2008 R2 directly instead of using the Build and Update utility. There's nothing of use on it at the moment so I'm totally open to wiping it again.

    Read the article

  • PostgresQL on Amazon EBS volume, realistic performance, or move to something more lightweight?

    - by Peck
    Hi, I'm working on a little research project, currently running as an instance on ec2, and I'm hoping to figure out whether I'm going down the right path. We, like a thousand other people, are making use of some of twitters streaming feeds to do gather some data to have fun with and my db seems to be having problems keeping up, and queries take what seems to be a very long time. I'm not a DBA by trade, so I'll just dump some info here and add more if need be. System specs: ec2 xl, 15 gigs of ram ebs: 4 100 gb drives, raid 0. The stream we're getting we're looking at around 10k inserts per minute. 3 main tables, with the users we're tracking somewhere in the neighborhood of 26M rows currently. Is this amount of inserts on this hardware too much to ask out of ebs? Should take a look at some things with less overhead like mongodb?

    Read the article

  • Installing W2K8 R2 on a Dell Poweredge 2850

    - by DerekT
    I'm a server novice and have been given a Dell 2850 (PERC 4e/Di). It has 3 blank HDs that I think are configured as RAID 5. I am trying to install W2K8 R2 SP1 on it. It doesn't have a DVD reader so I created an install USB. This works fine until it's time to copy files to the HD. It can't see a HD. There is an option to browse for drivers at this stage. Any idea what drivers I need and where to download them? I downloaded this driver RAID_DRVR_WIN_R227150.EXE but this failed with invalid signature. Thanks to dyasny for the link to LSI-LOGIC_MULTI-DEVICE_A00_R227150.exe.

    Read the article

  • Issues with non-HP harddisk in HP ML 350 server?

    - by Torben Warberg Rohde
    I'm looking to buy some extra disk space for a HP ML 350 G5 server. It is for simple file-serving - not OS/system stuff. HP harddisks are insanely expensive, so I'm tempted to buy some other brand instead. I have heard that they sometime use special firmware on their disks, but I suspect that might just be HP spreading rumors to sell disks. Does anyone have experience using non-HP disks? Any features not working, or not being able to build the RAID at all? I'm looking at 2.5" SAS Seagate drives - Constellation 500 GB (7.2k) or Savvio 600 GB (10k).

    Read the article

  • D-Link DNS-323 NAS firmware update

    - by Mark Beaton
    Hi all, I've got a D-Link DNS-323 NAS enclosure holding a bunch of multimedia files that I've (possibly stupidly) just updated the firmware on, from 1.03 to 1.08. The updater indicated it applied the firmware patch successfully, but after rebooting it I can no longer get into it via the web interface, either via the static IP I had assigned it before the update, or by any of the DHCP-assigned addresses that I can see are currently assigned by my router. The unit just sits there, with the drives (2x512 set up as RAID-1) thrashing away seemingly forever... So, my question - has anyone had a similar experience with one of these units? Any advice etc? I've googled the hell out of it, and can't find anything useful.

    Read the article

  • ZFS SAS/SATA controller recommendations

    - by ewwhite
    I've been working with OpenSolaris and ZFS for 6 months, primarily on a Sun Fire x4540 and standard Dell and HP hardware. One downside to standard Perc and HP Smart Array controllers is that they do not have a true "passthrough" JBOD mode to present individual disks to ZFS. One can configure multiple RAID 0 arrays and get them working in ZFS, but it impacts hotswap capabilities (thus requiring a reboot upon disk failure/replacement). I'm curious as to what SAS/SATA controllers are recommended for home-brewed ZFS JBODs. In addition, how does battery-backed write cache (BBWC) play into the solution?

    Read the article

  • Suppress log messages about 3ware disk temperature changes on CentOS?

    - by Stefan Lasiewski
    I have a number of CentOS 5 servers which use 3ware RAID controllers. These servers are bugging my team with messages about minor temperature changes, like this: Jun 8 12:32:39 HOST smartd[1231]: Device: /dev/twa0 [3ware_disk_01], SMART Usage Attribute: 194 Temperature_Celsius changed from 119 to 118 Jun 8 12:32:39 HOST smartd[1231]: Device: /dev/twa0 [3ware_disk_03], SMART Usage Attribute: 194 Temperature_Celsius changed from 122 to 121 How can I suppress these messages? According to man smartd.conf : To disable any of the 3 reports, set the corresponding limit to 0. Trailing zero arguments may be omitted. By default, all temperature reports are disabled (´-W 0´). On my systems, smartd is reporting about temperature changes by default. I tried a manual approach. In /etc/smartd.conf, I have the following: /dev/twa0 -d 3ware,1 -a -W 0 /dev/twa0 -d 3ware,3 -a -W 0 But this still does not suppress the messages. Since these messages show up in /var/log/messages, LogWatch is sending unnecessary emails every night.

    Read the article

  • FreeNas running on ESXi - sometimes gets very slugish.

    - by Luma
    Hello everyone, I have a ESXi server (dual quad core, 8GB of DDR3 ram, 6x 1TB WD Blacks running in RAid 5 on the PErc 6/i controller. I have a 64bit freenas VM running, on this VM I keep about 200Gigs of stuff that my windows machines access. every now and then the throughput of this VM just dies, for example right now it can't even handle streaming a song and when I tried to transfer a folder the speed goes from 10-400KB/s. Might I add at this point that the ESXi box has dual gigabit network cards plugged into a good solid gigabit switch and other linux and windows VM's are just fine I have seen speeds over 90MB/s (frequently) The server still has ram left over (plenty actually) and cpu is very low (500-1000mhz) any ideas what could cause this? thanks. Luc

    Read the article

  • How to perform diagnostics (stress test) on HP Smartarray Controller

    - by pepoluan
    At my office, we have a server that we suspect its RAID controller (HP Smartarray) is failing. A cold boot, however, does not indicate anything. Can anyone recommend me a method to stress-test the controller? Symptoms that makes me suspect a failing controller: Disk access getting slower, queue getting longer Running dmesg on the XenServer console I see many messages similar to this one: end_request: I/O error, dev tda, sector 253655584 (the sector number is never the same) When we move the VM to another physical host, we no longer see the above message Running idle (without any running VM), the dmesg no longer emit the above message A search on Google indicated that the above message is most commonly associated with a failing SmartArray controller. How can I be sure that the SmartArray controller is failing?

    Read the article

  • Identify SATA hard drive

    - by Rob Nicholson
    Very similar question to: Physically Identify the failed hard drive But for Windows 2003 this time. Scenario: Four identical SATA hard drives plugged into motherboard (no RAID controller here) Configured as single drive in Windows as a spanned volume One of them is starting to fail with error "The driver detected a controller error on \Device\Harddisk3" How do you cross-reference Harddisk3 to the physical SATA connection on the motherboard so you know which drive to replace? I know replacing this drive will trash the spanned array requiring it to be rebuilt anyway so my rough and ready solution is: Delete the spanned partition Create individual partitions on each drive labelled E: F: G: and H: and work out which one is Harddisk3 Power down, remove each disk one at a time, power-up until the drive letter disappears But this seems a rather crude method of identifying the drive. The SATA connectors will be numbered on the motherboard but I appreciate this might not cross-match to what Windows calls them. Thanks, Rob.

    Read the article

  • Using off-the-shelf hardware for brand-name servers; Possible? Good idea?

    - by threecheeseopera
    Is it possible or advisable to use 'regular' not-sanctioned-by-the-server-manufacturer hardware in high end servers? Often these manufacturer-supplied parts have a very high price markup, and I wonder if it's always necessary (understanding that they probably apply more rigorous requirements to this hardware). For example, Dell sells 300GB 15,000rpm serial-attached scsi drives for a certain server family for almost $600 each, while newegg sells a drive with the same specs for almost half the price http://www.newegg.com/Product/Product.aspx?Item=N82E16822116059. Do we really need to pay these high markups, especially for disks that are likely RAID-ed and so guarded against catastrophic failure?

    Read the article

< Previous Page | 57 58 59 60 61 62 63 64 65 66 67 68  | Next Page >