  • How to move an existing Win7 setup to a RAID-1 array?

    - by Matthew Scharley
    Currently I have a the following setup: Drive A/B: Identical HDD's Drive C: 2TB external drive with plenty of space currently. Hardware RAID controller Currently I have Drive A which is my boot drive (Win7), and Drive C which is a data drive, and Drive B which I only recently received and is blank. What is the best way of moving off of Drive A, setting up the hardware RAID and then migrating my data back onto the RAID array? I'm proficient with Linux, but I'm not sure if I can get away with simply using dd here. There is currently enough free space on Drive C to take 5-6 copies of a disk image of Drive A, so space isn't an issue.

    Read the article

  • Motherboard: Intel S5520HCR s1366 SSI EEB

    - by Crazy_Bash
    I'm building a storage server for online video streaming. I thought about adding two SSD drive for a OS. other 15*(12 SATA & 3 SSD) drives i want to build with aufs XFS and ethernet 4GB/sec network. But I'm confused a little. S5520HCR board supports 6, SATA/300, RAID: 0, 1, 10, Intel ICH10R. Does it mean i can use SATAIII HDD? I'm planing on buying SEAGATE SV35 Series (3.5, 3??, 64??, SATA III-600). also my Chassis supports up-to 16 sata and the motherboard only 6 what kind of sata controller should i use? What's better in terms of performance 1366 or 2011 socket? My server so far: AIC RSC-3EG-80R-SA1S-2 3U Motherboard: Intel S5520HCR s1366 SSI EEB Kingston DDR3 8192Mb PC3-10600 1333MHz (KVR1333D3N9/8G) Seagate 3000GB 64MB 3.5" 7200rpm SATAIII (ST3000DM001) Kingston 480GB SSD 2.5" SATAIII Intel E1G44HTBLK Intel Xeon E5606 2133MHz/L3-8192Kb/QPI s1366 tray SERVER ACC CARD SAS PCIE 16P HBA 9201-16I LSI00244 SGL LSI

    Read the article

  • 5 x 3GB drives and 4 x 1500GB drive best raid setup?

    - by Zen_Silence
    Hello, I am building a file server my plan is the have the Operating system on one raid partition and the data storage on another partition. I currently have 5 x 3GB IDE drives that i would like to put the operating system on theses drives are old but that doesnt matter to me at the moment i have a ton of them so for this raid partition i would probably want to be able to pull out dead a drive and rebuild the array. My file partition is going to consist of 4 x 1.5TB SATA drives I would like the maximum storage with some redundancy. Any suggestions to which Raid level i should use would be greatly appreciated and if you could also suggest a PCI or PCI-e raid controller to handle theses arrays. Thanks in Advance, Zen_Silence

    Read the article

  • ASUS P5B Plus motherboard - no any drives found - how to restore RAID array?

    - by Moha
    We have a small server machine with an ASUS P5B Plus motherboard and 4 SATA HDDs. The HDDs were configured in a RAID10 array. Up until now, everything worked fine, but now the system doesn't recognize the drives. BIOS is set to RAID, jMicron controller is set to RAID, yet I can't see any of the drives in the BIOS setup, and jMicron BIOS tells me "no any drives found" The HDDs all spin up, I hear no clicking sounds or anything that would suggest HDD error. I did a search on this problem and replaced the SATA cables as suggested, but nothing's changed. What I have in mind is checking the CMOS battery and resetting the BIOS to use IDE mode, but I don't know if it will ruin the RAID system on the HDDs. It is not a critical server and there's only one database running on it (which I have backup of), but I don't want to setup the server from scratch if not necessary. What should I try to restore the RAID array and put the server back to working order?

    Read the article

  • Users will be kicked out of a network drive (DFS)

    - by user71563
    Hi, In early January 2011, we completely switched to Windows Server 2008 R2 and Windows 7. On our domain controller set up a DFS is that the users as "Z: drive" is displayed. The DFS was it in the same way during our time with Windows Server 2003 R2 and Windows XP. At the time it has always worked without problems. Since Windows 7, we have sometimes the case that when a user accesses to the Z drive, the Explorer will return to the workplace without a user can do. After two to three trials of the Explorer remains in the network drive and the users work. This phenomenon occurs irregularly and you can not restrict exactly why. In the event log at the time no obvious entries are logged. Does anyone know the problem or has had similar experiences? I am grateful for any help. Greetings, sY!v3Rs

    Read the article

  • Jumbo Frames on DIR-655

    - by Spookyone
    I am trying to set up jumbo frames on my gigabit home LAN but no luck so far. My setup is: D-Link DIR-655 router, HW Revision A3, Firmware 1.21 EU Synology DS107+, Firmware 3.0-1337 Laptop w/ Win7 x64, external PCIx NIC managed by "Generic Marvel Yukon 88E8053 based Ethernet Controller" The router is supposed to support jumbo frames but doesn't feature any relevant setting. I set the Jumbo Packet value to 9000 on both the NIC and the Synobox but it doesn't work, ping -f -l 8972 says "Packet needs to be fragmented but DF set". Is there any other setting I overlooked, the DIR-655 doesn't actually support jumbo frames, or what else could be the problem?

    Read the article

  • Keyboard not responding during boot

    - by Peri
    My keyboard just stopped responding during boot. So I cannot go to BIOS or select system which I want to start. It is USB keyboard and it was working before. I borrowed PS2 keyboard and it also isn't working during boot. Lately I have been having problems with hard disk. Once every 2-5 minutes LED was on for 30 seconds and win7 wasn't responsive. I connected disk to another controller on motherboard and seems it is working now. All that suggests that to me that that motherboard is broken. What can I check? Or maybe you have some other suggestions?

    Read the article

  • Benefits of a RAID BBU in addition to a double UPS + PS system

    - by Wikser
    Today I roughly measured the benefits of enabling write-back on the RAID controller on a server at work. It got no RAID battery-backup-unit (BBU) so the write-cache is currently disabled. As the server is not used to capacity (by far), the results in most test were spectacular, e.g.: Database CRUD: before 35s, after 4s Saving a 1MB Excel file: before: 20s (!), after: 0.5s Of course having a BBU is always recommended, but what are the main benefits of installing a BBU to a system, which got redundant power supplies and is attached to UPSs? Does this depend on the type of the system (database, file, terminal)? What is a realistic fail scenario which could be prevented by a BBU? Thanks in advance!

    Read the article

  • Problem installing a w2k DC on Hyper-V?

    - by Tony
    Hi, We have a cluster with four node windows 2008 r2 and hyper-v installed. We would like to install 2 VM with role domain controller w2k (the domain is different from the domain of the hyper-v cluster). Do you know if there are any restriction on doing it? Some collegues say that we risk data corruption if we do live migrations. Others speak about the fact that Microsoft don't support w2k any more. And others have doubts because the global catalog server installed on these DC could have loss of performance. Any idea? Thanks Tony

    Read the article

  • RAID 1 after install and two controlers

    - by jfreak53
    I have question regarding RAID 1. Can I setup software RAID 1 after having installed the first drive and setup ubuntu 12? I know that during server install and partitioning I can select RAID and setup then, but what I am not clear on is how in the world to setup RAID 1 after the fact? Can someone provide directions for this? Also, can I RAID 1 two drives one being 500GB and the mirror drive being 1TB? Of course the mirror drive would have a 500GB partition but that's my point. Lastly, can one drive be on IDE and the other on a SATA controller? I know speed will be an issue, that doesn't matter, I just need to know if it will work without corrupting data and if it's the same process? Thanks.

    Read the article

  • Windows 2008 Enterprise License can't activate Standard Edition

    - by starchx
    We have downloaded and installed the Windows 2008 Standard R2 edition months ago. Now the server is in production. We signed up the Microsoft Partnership Action Pack subscription last week and get a license for Windows 2008 Enterprise edtion. I am trying to activate the standard edition with Enterprise key as advsied here:http://serverfault.com/questions/318968/upgrade-domain-controller-sku-from-server-2008-r2-standard-to-enterprise , but failed. Is it because windows 2008 we have is different? (downloaded from MS site with eval license). Thanks. tim

    Read the article

  • SSD on Vmware ESXI 4 (TRIM? Good Idea?)

    - by nextgenneo
    Hi, I just posted about finding bottle necks and have narrowed it down to having way too many VMs on my machine on one 15K SAS drive. I have plenty of cores and plenty of ram. So I am planning on putting 6 VMs on one drive (so 5 drives for 30 VMs). I am thinking of using a 60GB Vertex 2 SSD. Each of my VMs will only need about 6GB of HDD space so this isn't a big deal. My questions are: does ESXI support Trim and do I really need it if I leave 25% of the drive as free space? If I need it should I get a diff drive that handles garbage collection differently? I have a RAID controller w/ write caching. I will still benefit from this? Will this effect my setup differently? Is there anything I need to consider regarding SSD's in virtualized environments. Thanks for any and all help!

    Read the article

  • Can a RAID 4 disk setup crash if only 1 hard disk fails?

    - by Steve Rodrigue
    I am a web developer. I have not much experience in hardware. For this reason, I use managed servers. This morning, one of the drives in our setup failed. However, the full site went down. I asked my web host what happened and he replied that the hard disk failed in such a way that the RAID controller couldn't work properly. The array was set up as RAID 4. Do you guys ever seen that before? Is it possible? Thanks for any help on this guys. I need to know if my web host is honest with me.

    Read the article

  • Windows PC's Intermittant Network faults.

    - by Kristiaan
    Hello everyone, im running into some issues with our client PC's (windows xp sp3 systems). this morning we ran into some problems with PC's not connecting to internal / external systems intermittantly. this would manifest as a problem connecting to any service, email, web, backoffice database systems etc. given a random amount of time be it a few minutes etc the problem would disapear and the pc would carry on as normal, some systems however have not been able to connect to certain sytems since the problem initally happened. im hoping for some suggestions / network diag advice really to help me locate the cause of this problem. all the clients are windows xp, connecting to a domain controller that is windows 2003 std this server also acts as a DNS server for us. we also have websense 7.0.1 installed on it to filter traffic.

    Read the article

  • Removing integrated video card drivers broke other hardware?

    - by jsnlxndrlv
    I just purchased and installed an XFX ATI Radeon HD 4650 video card. The installation instructions said to remove the old video card drivers before installing the new driver. I did both things, but now every time I start my computer, the Found New Hardware wizard pops up for the following three devices: PCI Device SM Bus Controller Other PCI Bridge Device Furthermore, my LAN port no longer functions. The cable's connected, and the light on the port comes on, but the computer can't find any servers when I attempt to connect with it. The modem and router are working, and obviously I'm able to use the other computer here to post this. What do I do to fix this?

    Read the article

  • When XP is asleep for a long time LAN reports code 43, gives up the ghost.

    - by seeanimal
    This one's got me stumped. Whenever the system is asleep for a long time, e.g overnight, the LAN driver reports error code 43 ("a problem") and turns itself off. This has being going on for months, but I never caught the problem until now. The owner merely shuttles back to a restore point I set her when the machine worked. Previously (without knowing exactly what was happening) I have tried everything to resolve this. Manually resetting the TCP/IP, fiddling with the driver Wake From LAN settings, DIFFERENT drivers, etc. etc. The solution is easy, uninstalling and reinstalling the driver. Understandably, though, the user is uncomfortable with this operation and the problem persists. What's causing it and how to stop it recurring? Any ideas? Thanks in advance to this great community. XP home SP3, Marvell Yukon 88E8056 PCI-E Gigabit Ethrnet Controller, version 10.22.7.3 (yk51x86.sys)

    Read the article

  • parallel to usb driver windows 7 dot matrix printer

    - by user975234
    I recently built a new Core i5 system with Windows 7 Professional. I had planned to hook up my TVS MSP 250 XL printer using a USB to parallel cable Once I plug the cable in, Windows 7 recognizes it as an IEEE-1284 controller and automatically installs the appropriate driver. However, in the status window it reports the following: "USB Printing Support -- Ready to use" "No Printer Attached -- Ready to use" When I then go ahead and manually add the printer using the "virtual printer port for USB" I can add the printer seemingly without problem. Once finished, it appears in the Devices and Printers panel. Yet, all attempts to print on this printer fail. It appears that simply no data is sent to the printer (either by programs like word or adobe or by attempting to print a test page. Does anybody know how to fix this?

    Read the article

  • Group policies - WSUS

    - by cory
    Hello, I am really lost as to what is the reason as to why my group policy is not working on my domain. I have setup a GPO for my wsus server to a specific OU in my domain. It seems as of right now, none of my machines have inherited that GPO. I have manually put it in quite a few computers. Most of my computers in the domain are linked up to my wsus server, but all my desired settings are not there. If I run gpresult /R, On one computer I ran this on, it is linking to my backup domain controller and not my main. On another computer I checked this on, it is linking to my main DC, but it did no inherit the GPO. When looking on my DC on gpmc - I see the policy is forced to the OU as #1 precedence. Thank for any help.

    Read the article

  • Running out of space on a SAS-based workstation

    - by SteveWilkinson
    Hi - first question on serverfault - pls excuse if asked elsewhere. I have a Dell Precision 690 with one 73GB (15000RPM) SAS drive in it. Running Windows 7 (x64) with a bunch of apps means it is running out of space. I have on order a 147GB (15000RPM) SAS drive (same GB/s, same make) which I want to put into the machine. Not knowing anything about SAS, do I need to replace the 73GB with the 147GB and restore from a backup, or can I put the drive in the machine and get the controller to treat the two drives as one large one? (The original paperwork for the machine says 73GB SAS (No RAID) if that is relevant.) Thanks in advance.

    Read the article

  • Running out of space on a SAS-based workstation

    - by SteveWilkinson
    Hi - first question on serverfault - pls excuse if asked elsewhere. I have a Dell Precision 690 with one 73GB (15000RPM) SAS drive in it. Running Windows 7 (x64) with a bunch of apps means it is running out of space. I have on order a 147GB (15000RPM) SAS drive (same GB/s, same make) which I want to put into the machine. Not knowing anything about SAS, do I need to replace the 73GB with the 147GB and restore from a backup, or can I put the drive in the machine and get the controller to treat the two drives as one large one? (The original paperwork for the machine says 73GB SAS (No RAID) if that is relevant.) Thanks in advance.

    Read the article

  • large RAID 10 vs small RAID1

    - by user116399
    The machine will store and serve millions of small files (<15Kb each), and all those files require a total storage space of 400G Considering the exact same SATA hard drives maker and models, on the exact same environment (OS, cpu, ram, raid controller, etc...) which one of the setups bellow would be faster? A) RAID 1 with 2 drives of 2T each, making up total storage of 2T B) RAID 10 with 4 drives of 2T each, making up total storage of 4T [EDIT]: I'm aware RAID10 is faster than RAID1. The larger the disk, at least in theory, the longer will take to do seeks/writes. So, will the performance gain of RAID10 will be outweighed by the "drag" caused the larger disk area when seek/write operations happened?

    Read the article

  • Limit a process's relative (not absolute) processor consumption in Linux

    - by BobBanana
    What is the standard way in Linux to enforce a system policy to limit the relative CPU use of a single process? That is, on a quad-core machine, I never want a process to use more than 2 CPUs at once, even if the process creates more threads. I do not want an absolute time limit, just a relative limit so that one task cannot dominate the machine. This is also different than renice, which allows a process to use all the resources but just politely step aside if others need them too. ulimit is the usual resource limiting tool, but it does not allow such CPU restrictions.. it can limit the number of processes per user, or absolute CPU time, not restrict the maximum number of active threads of a single process. I've found a couple of user-level tools, like CPUlimit, but not a system level tool or setting. Does such a standard resource controller exist in Linux (Red Hat Enterprise, if it matters.) If there is such a limit imposed, how would a user identify it?

    Read the article

  • Throwing TRIM support in Ubuntu guest at Win7-Virtualbox host

    - by user141472
    I have VirtualBox 4.1.14 on Windows 7 as host, and Ubuntu server 11.10 as guest. System was installed at traditional HDD years ago (and upgraded later), but now it's at SSD as expanding drive. There is "AHCI" and "it's SSD" features enabled in SATA controller. Problem is, this expanding drive growth to it's almost max size (90% of it), but actually in VM only about 50% spent. Also, guest VM does not recognize /dev/sda as SSD, /sys/block/sda/queue/rotational says "1", /sys/block/sda/queue/discard_* all says "0". And, of course, I cannot run fstrim /, it says that operation not supported. Is there some trick to enable TRIM support in my guest system without reinstalling it?

    Read the article

  • HP DL380 G5 Predictive failure of a new drive

    - by CharlieJ
    Consolidated Error Report: Controller: Smart Array P400 in slot 3 Device: Physical Drive 1I:1:1 Message: Predictive failure. We have an HP DL380 G5 server with two 72GB 15k SAS drives configured in RAID1. A couple weeks ago, the server reported a drive failure on Drive 1. We replaced the drive with a brand new HDD -- same spares number. A few days ago, the server started reporting a predictive drive failure on the new drive, in the same bay. Is it likely the new drive is bad... or more likely we have a bay failure problem? This is a production server, so any advice would be appreciated. I have another spare drive, so I can hot swap it if this is a fluke and new drive is just bad. THANKS! CharlieJ

    Read the article

  • aireplay - reading but not sending

    - by oneat
    I'm trying aircrack injection, everything is working I authenticated, but aireplay is not working aireplay-ng -3 -b 00:12:2A:01:74:05 -h 78:e4:00:87:71:8b mon0 18:53:03 Waiting for beacon frame (BSSID: 00:12:2A:01:74:05) on channel 7 Saving ARP requests in replay_arp-0817-185303.cap You should also start airodump-ng to capture replies. Read 4988 packets (0 ARPs, 4 ACKs), sent 0 packets...(0 pps) Why isn't it working? Why isn't it sending packets? 03:00.0 Network controller: Atheros Communications Inc. AR928X Wireless Network Adapter (PCI-Express) (rev 01) I tested injection on injection test in aircrack tutorial, despite driver wasn't patched.