Search Results

Search found 64721 results on 2589 pages for 'windows usb drive'.

Page 637/2589 | < Previous Page | 633 634 635 636 637 638 639 640 641 642 643 644  | Next Page >

  • WinRT GridView scrolling setup work differently on mouse/kb and touch

    - by Jay Kannan
    I'm trying to mimic the functionality of the NetFlix app, with a strip on the left that collapses on scrolling, I had to offset the tiles on the GridView a bit to the right so that they can accomodate that behavior. They seem to work alright in keyboard and scroll completely to the right (although I noticed the scrollbar suddenly grows in size when I hit the left boundaries. this totally changes when I use it on touch - I seem to have a limit on the right and the scrolling doesnt scroll past the last 100 pixels or so. how do I take care of this. I'm assuming it is related to the bug here, but didn't seem to solve the problem with that solution there. "Sticky scrolling" issue in WinRT XAML GridView control

    Read the article

  • Remove Kernel Lock from Unmounted Mass Storage USB Device from the Command Line in Linux

    - by Casey
    I've searched high and low, and can't figure this one out. I have a older Olympus Camera (2001 or so). When I plug in the USB connection, I get the following log output: $ dmesg | grep sd [20047.625076] sd 21:0:0:0: Attached scsi generic sg7 type 0 [20047.627922] sd 21:0:0:0: [sdg] Attached SCSI removable disk Secondly, the drive is not mounted in the FS, but when I run gphoto2 I get the following error: $ gphoto2 --list-config *** Error *** An error occurred in the io-library ('Could not lock the device'): Camera is already in use. *** Error (-60: 'Could not lock the device') *** What command will unmount the drive. For example in Nautilus, I can right click and select "Safely Remove Device". After doing that, the /dev/sg7 and /dev/sdg devices are removed. The output of gphoto2 is then: # gphoto2 --list-config /Camera Configuration/Picture Settings/resolution /Camera Configuration/Picture Settings/shutter /Camera Configuration/Picture Settings/aperture /Camera Configuration/Picture Settings/color /Camera Configuration/Picture Settings/flash /Camera Configuration/Picture Settings/whitebalance /Camera Configuration/Picture Settings/focus-mode /Camera Configuration/Picture Settings/focus-pos /Camera Configuration/Picture Settings/exp /Camera Configuration/Picture Settings/exp-meter /Camera Configuration/Picture Settings/zoom /Camera Configuration/Picture Settings/dzoom /Camera Configuration/Picture Settings/iso /Camera Configuration/Camera Settings/date-time /Camera Configuration/Camera Settings/lcd-mode /Camera Configuration/Camera Settings/lcd-brightness /Camera Configuration/Camera Settings/lcd-auto-shutoff /Camera Configuration/Camera Settings/camera-power-save /Camera Configuration/Camera Settings/host-power-save /Camera Configuration/Camera Settings/timefmt Some things I've tried already are sdparm and sg3_utils, however I am unfamiliar with them, so it's possible I just didn't find the right command. Update 1: # mount | grep sdg # mount | grep sg7 # umount /dev/sg7 umount: /dev/sg7: not mounted # umount /dev/sdg umount: /dev/sdg: not mounted # gphoto2 --list-config *** Error *** An error occurred in the io-library ('Could not lock the device'): Camera is already in use. *** Error (-60: 'Could not lock the device') ***

    Read the article

  • OpenFileDialog.AutoUpgradeEnabled doesn't work under 7?

    - by Digiku
    If I specify OpenFileDialog.AutoUpgradeEnabled = true, my program still shows the old XP-style dialog. Any idea why this would happen? This is after I enable theming in Main() [STAThread] static void Main() { Application.EnableVisualStyles(); Application.Run(new Primary()); } and this is my dialog code: private void OpenProgramFile() { OpenFileDialog programFileDialog = new OpenFileDialog(); programFileDialog.Filter = "Program files (*.exe;*.lnk)|*.exe|All files (*.*)|*.*"; programFileDialog.FilterIndex = 0; programFileDialog.Title = "Select program file"; programFileDialog.AutoUpgradeEnabled = true; programFileDialog.ShowHelp = true; DialogResult fileResult = programFileDialog.ShowDialog(); if (fileResult != DialogResult.OK) return false; programFileDialog.Dispose(); } So why would AutoUpgradeEnabled not work on 7?

    Read the article

  • deleting HBITMAP causes an access violation at runtime.

    - by Oliver
    Hi, I have the following code to take a screenshot of a window, and get the colour of a specific pixel in it: void ProcessScreenshot(HWND hwnd){ HDC WinDC; HDC CopyDC; HBITMAP hBitmap; RECT rt; GetClientRect (hwnd, &rt); WinDC = GetDC (hwnd); CopyDC = CreateCompatibleDC (WinDC); //Create a bitmap compatible with the DC hBitmap = CreateCompatibleBitmap (WinDC, rt.right - rt.left, //width rt.bottom - rt.top);//height SelectObject (CopyDC, hBitmap); BitBlt (CopyDC, //destination 0,0, rt.right - rt.left, //width rt.bottom - rt.top, //height WinDC, //source 0, 0, SRCCOPY); COLORREF col = ::GetPixel(CopyDC,145,293); // Do some stuff with the pixel colour.... delete hBitmap; ReleaseDC(hwnd, WinDC); ReleaseDC(hwnd, CopyDC); } the line 'delete hBitmap;' causes a runtime error: an access violation. I guess I can't just delete it like that? Because bitmaps take up a lot of space, if I don't get rid of it I will end up with a huge memory leak. My question is: Does releasing the DC the HBITMAP is from deal with this, or does it stick around even after I have released the DC? If the later is the case, how do I correctly get rid of the HBITMAP?

    Read the article

  • WinDbg fails to find symbol file reporting 'unrecognized OMF sig'

    - by sean e
    I have received a 64bit dump of a 32bit app that was running on Win7 x64. I am able to load it in WinDbg (hint: !wow64exts.sw) running on a 64bit OS. The symbols for most of my dlls are loaded properly. The pdb for one though does not load. The same pdb does load properly for the same dll when reading a 32bit dump on a different system. I've also confirmed that the dll and pdb match each other via the chkmatch utility. I tried .symopt +40 but the pdb still didn't load. I did !sym noisy then .reload - WinDbg reported: DBGHELP: unrecognized OMF sig: 811f1121 *** ERROR: Symbol file could not be found. Defaulted to export symbols Any ideas on what to try to get WinDbg to load my pdb when reading a 64bit dump?

    Read the article

  • Why Basic HTML gets loaded

    - by Priyanka
    Hello... When I browse internet,basic HTML gets loaded on my computer. For eg.- for orkut or facebook login,only the text box appears,and when inputs are provided,and redirection is done,it says "error on page". Even on google search,basic HTML gets loaded on my computer.. I tried installing new Internet version i.e., IE8,but the same problem. Kildly provide a good solution to this problem.

    Read the article

  • Making sense of S.M.A.R.T

    - by James
    First of all, I think everyone knows that hard drives fail a lot more than the manufacturers would like to admit. Google did a study that indicates that certain raw data attributes that the S.M.A.R.T status of hard drives reports can have a strong correlation with the future failure of the drive. We find, for example, that after their first scan error, drives are 39 times more likely to fail within 60 days than drives with no such errors. First errors in re- allocations, offline reallocations, and probational counts are also strongly correlated to higher failure probabil- ities. Despite those strong correlations, we find that failure prediction models based on SMART parameters alone are likely to be severely limited in their prediction accuracy, given that a large fraction of our failed drives have shown no SMART error signals whatsoever. Seagate seems like it is trying to obscure this information about their drives by claiming that only their software can accurately determine the accurate status of their drive and by the way their software will not tell you the raw data values for the S.M.A.R.T attributes. Western digital has made no such claim to my knowledge but their status reporting tool does not appear to report raw data values either. I've been using HDtune and smartctl from smartmontools in order to gather the raw data values for each attribute. I've found that indeed... I am comparing apples to oranges when it comes to certain attributes. I've found for example that most Seagate drives will report that they have many millions of read errors while western digital 99% of the time shows 0 for read errors. I've also found that Seagate will report many millions of seek errors while Western Digital always seems to report 0. Now for my question. How do I normalize this data? Is Seagate producing millions of errors while Western digital is producing none? Wikipedia's article on S.M.A.R.T status says that manufacturers have different ways of reporting this data. Here is my hypothesis: I think I found a way to normalize (is that the right term?) the data. Seagate drives have an additional attribute that Western Digital drives do not have (Hardware ECC Recovered). When you subtract the Read error count from the ECC Recovered count, you'll probably end up with 0. This seems to be equivalent to Western Digitals reported "Read Error" count. This means that Western Digital only reports read errors that it cannot correct while Seagate counts up all read errors and tells you how many of those it was able to fix. I had a Seagate drive where the ECC Recovered count was less than the Read error count and I noticed that many of my files were becoming corrupt. This is how I came up with my hypothesis. The millions of seek errors that Seagate produces are still a mystery to me. Please confirm or correct my hypothesis if you have additional information. Here is the smart status of my western digital drive just so you can see what I'm talking about: james@ubuntu:~$ sudo smartctl -a /dev/sda smartctl version 5.38 [x86_64-unknown-linux-gnu] Copyright (C) 2002-8 Bruce Allen Home page is http://smartmontools.sourceforge.net/ === START OF INFORMATION SECTION === Device Model: WDC WD1001FALS-00E3A0 Serial Number: WD-WCATR0258512 Firmware Version: 05.01D05 User Capacity: 1,000,204,886,016 bytes Device is: Not in smartctl database [for details use: -P showall] ATA Version is: 8 ATA Standard is: Exact ATA specification draft version not indicated Local Time is: Thu Jun 10 19:52:28 2010 PDT SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x002f 200 200 051 Pre-fail Always - 0 3 Spin_Up_Time 0x0027 179 175 021 Pre-fail Always - 4033 4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 270 5 Reallocated_Sector_Ct 0x0033 200 200 140 Pre-fail Always - 0 7 Seek_Error_Rate 0x002e 200 200 000 Old_age Always - 0 9 Power_On_Hours 0x0032 098 098 000 Old_age Always - 1468 10 Spin_Retry_Count 0x0032 100 100 000 Old_age Always - 0 11 Calibration_Retry_Count 0x0032 100 100 000 Old_age Always - 0 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 262 192 Power-Off_Retract_Count 0x0032 200 200 000 Old_age Always - 46 193 Load_Cycle_Count 0x0032 200 200 000 Old_age Always - 223 194 Temperature_Celsius 0x0022 105 102 000 Old_age Always - 42 196 Reallocated_Event_Count 0x0032 200 200 000 Old_age Always - 0 197 Current_Pending_Sector 0x0032 200 200 000 Old_age Always - 0 198 Offline_Uncorrectable 0x0030 200 200 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x0032 200 200 000 Old_age Always - 0 200 Multi_Zone_Error_Rate 0x0008 200 200 000 Old_age Offline - 0

    Read the article

  • VBScript file open dialog that works in XP and Vista?

    - by codeulike
    In XP, you can use VBScript with the UserAccounts.CommonDialog object to bring up a File Open dialog (as described here), but apparently this does not work under Vista. Is there a VBScript method for File-Open dialogs that will work for both? Or even one that will work nicely for Vista? Disclaimer: I'm a proper programmer, honest, and don't usually work with VBScript - I am asking this question 'for a friend'.

    Read the article

  • New XPC: No video, no ethernet link, but drive spins

    - by Mike Pennington
    I bought a Shuttle XPC SH67H3 with integrated video. I installed: An Intel i5 2450P 16GB DDR3 RAM A SATA hard drive from my old linux server that still is bootable I have both power connectors plugged into the motherboard. I realize that the Intel i5-2450P doesn't have video capabilities; however, the drive spins like it's doing something useful. It seems like I should get an ethernet link light when I fire this up. I plan to run this headless anyway, so it would be really nice if I could figure out how to run this without a video card at all. I know the IP address and login info for the linux install on the disk. I plugged in speakers, but get no bios beeps when I power it up. Shuttle's bios manual has nothing in there that indicates I should have problems in this configuration. My questions: Is there a reason that the missing video card would block usage of the ethernet port? Are there settings on the motherboard / bios I can change to get this working?

    Read the article

  • OpenFileDialog.AutoUpgradeEnabled doesn't work under Vista or 7?

    - by Digiku
    If I specify OpenFileDialog.AutoUpgradeEnabled = true, my program still shows the old XP-style dialog. Any idea why this would happen? This is after I enable theming in Main() [STAThread] static void Main() { Application.EnableVisualStyles(); Application.Run(new Primary()); } and this is my dialog code: private void OpenProgramFile() { OpenFileDialog programFileDialog = new OpenFileDialog(); programFileDialog.Filter = "Program files (*.exe;*.lnk)|*.exe|All files (*.*)|*.*"; programFileDialog.FilterIndex = 0; programFileDialog.Title = "Select program file"; programFileDialog.AutoUpgradeEnabled = true; programFileDialog.ShowHelp = true; DialogResult fileResult = programFileDialog.ShowDialog(); if (fileResult != DialogResult.OK) return false; programFileDialog.Dispose(); } So why would AutoUpgradeEnabled not work?

    Read the article

  • How to make a huge ram drive?

    - by Brandon Moore
    At my old job when a report was needed I could sit down with someone and pull up results and get immediate feedback, and then refine my queries and ultimately have the data we needed, in the format we needed within 30-90 minutes. I just started working for a new company with a database containing millions of records and I spent my whole 8 hours making a report that I feel I could have made in less than 2 hours if it were not for the massive amount of data the queries are working with, and the fact that I couldn't ask the person needing the data to sit down with me and give me feedback as I pulled up results as I am used to. So I am trying to think of how we can make the server faster... much faster, so that I can have the same level of productivity I'm used to. One thought that just came to mind is that memory is so cheap these days, and by my calculations I could buy 10 8gig ram sticks for 1000 bucks. What I have never heard of though is a device that would let me combine these into a huge ram drive. So I'd like to know if any such device exists, and if not what is the largest ram drive I could realistically make and how would I go about doing so? EDIT: To you guys who are saying the database shema needs to be analyzed... you can't make a query such as "Select f1, f2, f3, etc from SomeTable" run any faster by normalizing or indexing the table. What I'm talking about IS ABSOLUTELY a need for improved performance at the hardware level. I am used to having results come back to me in a few seconds, not a few minutes or much less a half an hour. Maybe that's what you guys are used to who have 100 billion record tables and you feel like that's fast, but I'm looking for results back from tables with about 10 million records to come back to me withing less than half a minute TOPS.

    Read the article

  • My schtasks don't schedule anything. :(

    - by Waffles
    I'm trying to make a scheduled task, and its just not working for me. This is the command I type in CMD: schtasks /create /sc minute /mo 1 /tn test /tr calc.exe /st 19:17:00 /sd 12/14/2009 I'm trying to tell the computer to run calculator every minute starting at 7:09 PM. Although I get a success message after I type this in and hit enter, nothing happens at 7:09. What gives? Thanks in advance.

    Read the article

  • TextRenderer.DrawText renders Arial differently on XP vs Vista

    - by Michael
    I have a c# application that does text rendering, something on par with a simple wysiwyg text editor. I'm using TextRenderer.DrawText to render the text to the screen and GetTextExtentPoint32 to measure text so I can position different font styles/sizes on the same line. In Vista this all works fine. In XP however, Arial renders differently, certain characters like 'o' and 'b' take up more width than in Vista. GetTextExtentPoint32 seems to be measuring the string as it would in Vista though, with the smaller widths. The end result is that every now and then a run of text will overlap the text preceding it because the preceding text gets measured as smaller than it actually is on the screen. Also, my text rendering code mimics ie's text rendering exactly (for simple formatting and english language only) and ie text rendering seems to be consistent between vista and xp - that's how I noticed the change in size of the different characters. Anyone have any ideas about what's going on? In short, TextRenderer.DrawText and GetTextExtentPoint32 don't match up in xp for Arial. DrawText seems to draw certain characters larger and/or smaller than it does in Vista but GetTextExtentPoint32 seems to be measuring the text as it would in Vista (which seems to match the text rendering in ie on both xp and vista). Hope that makes sense. Note: unfortunately TextRenderer.MeasureString isn't fast or accurate enough to meet my requirements. I tried using it and had to rip it out.

    Read the article

  • Any Win32 APIs to get the screenshots?

    - by Microkernel
    Hi all, I am writing an app, which needs to take the screen shots automatically (just like pressing PrintScreen button). So please suggest me how to get this done. A raw 24 bit BMP image would suffice. PLEASE NOTE: My app is in C, so any win32 APIs that can be called from my code is what I am looking for. (Sometimes back I had got an example code from codeproject which used to get the screen shots but the mouse pointer user to blink when the screen shot is taken. As multiple shots are taken this looks irritating to the user, so I don't want the mouse pointer to blink!) Regards, Chethan KR

    Read the article

  • Optimal file system type and mount options for an rsnapshot dedicated drive

    - by Nimmy Lebby
    We have an external USB 2 drive that we are using as a backup drive for our configuration. We use rsnapshot for the backups. It uses a few standard commands for managing snapshots: rm -rf: deletes expired snapshots mv: moves older snapshots down a slot cp -al: duplicates last snapshot to new slot rsync -a --delete --numeric-ids --relative: synchronizes new snapshot As you could see by the log below, the majority of the time is spent on the rm -rf and the cp -al steps: [25/Dec/2010:14:00:02] rsnapshot hourly: started [25/Dec/2010:14:00:02] echo 21012 > /var/run/rsnapshot.pid [25/Dec/2010:14:00:02] rm -rf /mnt/extdrive/snapshots/hourly.5/ [25/Dec/2010:14:15:48] mv /mnt/extdrive/snapshots/hourly.4/ /mnt/extdrive/snapshots/hourly.5/ [25/Dec/2010:14:15:48] mv /mnt/extdrive/snapshots/hourly.3/ /mnt/extdrive/snapshots/hourly.4/ [25/Dec/2010:14:15:48] mv /mnt/extdrive/snapshots/hourly.2/ /mnt/extdrive/snapshots/hourly.3/ [25/Dec/2010:14:15:48] mv /mnt/extdrive/snapshots/hourly.1/ /mnt/extdrive/snapshots/hourly.2/ [25/Dec/2010:14:15:48] cp -al /mnt/extdrive/snapshots/hourly.0 /mnt/extdrive/snapshots/hourly.1 [25/Dec/2010:14:23:32] rsync -a --delete --numeric-ids --relative /etc /mnt/extdrive/snapshots/hourly.0/sm4/ [25/Dec/2010:14:23:52] touch /mnt/extdrive/snapshots/hourly.0/ [25/Dec/2010:14:23:52] rm -f /var/run/rsnapshot.pid [25/Dec/2010:14:23:52] rsnapshot hourly: completed successfully My questions: I'm currently using ext4 for the filesystem. Maybe this is not the best choice from those available in Red Hat. Anyone have any recommendations that would speed up the process? The partition's mount options are sync,dirsync 1 2. Is there a way to optimize this since it's solely used for rsnapshot? Of course, reasoning would be greatly appreciated.

    Read the article

  • Need GDI programming Guideline

    - by Arman
    I want to change my window design rapidly. I have OnPaint function which I am calling when WM_PAINT message received. The design change only when the event occure. I want that design should automatically update doesn't depend on event kindly guide me how can I make it possible.

    Read the article

  • How to move a sata drive to a machine without AHCI mode

    - by Andrew Cooper
    I've got a Dell Inspiron 1545 on which the screen has died. I'm able to plug an external monitor into the Inspiron 1545 and it works fine, so the screen is the only issue. The OS is Win7. I'm trying to move the disk to a spare Dell Precision M90 laptop that I've got lying around. The problem is that almost as soon as the Windows logo appears in the boot sequence I get a BSOD with a STOP 0x0000007B message. Researching this message pointed to issues with SATA AHCI mode. I looked in the BIOS of the Inspiron 1545 and the controller was set to AHCI mode. I set it to ATA mode and tried to boot with the same drive and got the same result as on the Precision M90. Switching back to AHCI allowed the machine to boot correctly again. I checked the BIOS on the Precision M90 and it doesn't seem to support AHCI mode, although it is a SATA controller onboard. The BIOS is the latest A08 version available from Dell. Is there any way I can get this drive to boot in the M90 without reformatting it?

    Read the article

  • can't backup to a NAS drive as offline schedule task

    - by imageng
    I have seen this problem issue discussed in several forums including this one, but could not find a solution. On MS server 2003 I configured a Backup task, the target backup is on a NAS disc (Seagate BlackArmor NAS 110). The backup task is working well as a scheduled task or by a direct command, when I am logged on. It is not working when the user is offline (in this case - Administrator). I already tried the following actions: 1) addressing to the target as network drive (Y:location..), 2)Using UNC instead, 3) making the drive a domain member (the NAS admin S/W allows to define itself as a domain member) The result log message for 1 and 2 is: "The operation was not performed because the specified media cannot be found." The result log message for 3 is empty file. The schedule task "RUN" command is: C:\WINDOWS\system32\ntbackup.exe backup "@C:\Documents and Settings\Administrator\Local Settings\Application Data\Microsoft\Windows NT\NTBackup\data\de-board.bks" /a /d "Set created 2/14/2010 at 5:10 PM" /v:yes /r:no /rs:no /hc:off /m incremental /j "de-board" /l:s /f "\10.0.0.8\public\Backups\IBMServer\de-board.bkf" 10.0.0.8 is the static IP of the NAS. "Run only if logged on" is NOT marked. Password of the administrator user is set. It is obvious that there is no access to the NAS when the user is logged-out. Do you have any idea how can I solve it? Thanks

    Read the article

  • Web App Server hardware question. Which configuration?

    - by JBeckton
    I am pricing some new servers and I am not sure which configuration to get. The server will be running some web applications for our company. Some of them are ASP.Net sites and some are ColdFusion. The OS will be Win Server 2008 Web or Standard Edition. Do I need 2 processors or will a single quad core handle it? Xeon multi core Hyperthreading or non Hyperthreading? I am going 64bit so I can go higher than 4 Gigs of Ram. I am shopping at Dell and there are so many options, i do not want to get too much hardware and not use half of it because that would be a waste of money and I do not want to get too little and have to ask for more money to upgrade it later.

    Read the article

  • StorageClientException: The specified message does not exist?

    - by Aaron
    I have a simple video encoding worker role that pulls messages from a queue encodes a video then uploads the video to storage. Everything seems to be working but occasionally when deleting the message after I am done encoding and uploading I get a "StorageClientException: The specified message does not exist." Although the video is processed, I believe the message is reappearing in the queue because it's not being deleted correctly. Is it possible that another instance of the Worker role is processing and deleting the message? Doesn't the GetMessage() prevent other worker roles from picking up the same message? Am I doing something wrong in the setup of my queue? What could be causing this message to not be found on delete? some code... //onStart() queue setup var queueStorage = _storageAccount.CreateCloudQueueClient(); _queue = queueStorage.GetQueueReference(QueueReference); queueStorage.RetryPolicy = RetryPolicies.Retry(5, new TimeSpan(0, 5, 0)); _queue.CreateIfNotExist(); public override void Run() { while (true) { try { var msg = _queue.GetMessage(new TimeSpan(0, 5, 0)); if (msg != null) { EncodeIt(msg); PostIt(msg); _queue.DeleteMessage(msg); } else { Thread.Sleep(WaitTime); } } catch (StorageClientException exception) { BlobTrace.Write(exception.ToString()); Thread.Sleep(WaitTime); } } }

    Read the article

  • Shrinking a large transaction log on a full drive

    - by Sam
    Someone fired off an update statement as part of some maintenance which did a cross join update on two tables with 200,000 records in each. That's 40 trillion statements, which would explain part of how the log grew to 200GB. I also did not have the log file capped, which is another problem I will be taking care of server wide - where we have almost 200 databases residing. The 'solution' I used was to backup the database, backup the log with truncate_only, and then backup the database again. I then shrunk the log file and set a cap on the log. Seeing as there were other databases using the log drive, I was in a bit of a rush to clean it out. I might have been able to back the log file up to our backup drive, hoping that no other databases needed to grow their log file. Paul Randal from http://technet.microsoft.com/en-us/magazine/2009.02.logging.aspx Under no circumstances should you delete the transaction log, try to rebuild it using undocumented commands, or simply truncate it using the NO_LOG or TRUNCATE_ONLY options of BACKUP LOG (which have been removed in SQL Server 2008). These options will either cause transactional inconsistency (and more than likely corruption) or remove the possibility of being able to properly recover the database. Were there any other options I'm not aware of?

    Read the article

  • Most useful Explorer shell extensions

    - by pablo
    I'd like to know which are the most common (and useful) shell extensions you're using as developers. I bet the following are on the list, but I'd like to know which others you would add: Tortoise SVN Tortoise Hg Tortoise XXX (Git, CVS, whatever) Any others worth mentioning?

    Read the article

  • How VerticalOffset changes when Scrollable height changes while having list inside a list

    - by Prakash
    I am making a WP7 app which has a Listbox of UserControls. Each UserControl has an ItemsControl and Button(for getting more results). On click of the button the ItemsControl items will be increased by 5 or 10. Now on clicking on the GetMore button of any of the usercontrols except the first or last, there will be an increase in Scrollable height(Total height of the listbox) of the ListBox but the VerticalOffset(position of scrollbar from top) of the ListBox remains same. Now the problem I am facing is that the Vertical Offset is not absolute but relative to Scrollable Height. So the content being viewed till then will be changed basing on the new value of ScollableHeight. I want to know the relation between them, so that I can do some math and set the VerticalOffset value. I have added some dependency properties on VerticalOffset and ScrollableHeight through which I can get the events when any of them is changed. Also trying to use them to readjust the VerticalOffset. Any suggestions or corrections are highly appreciated.

    Read the article

< Previous Page | 633 634 635 636 637 638 639 640 641 642 643 644  | Next Page >