Search Results

Search found 20693 results on 828 pages for '24 hours of pass'.

Page 78/828 | < Previous Page | 74 75 76 77 78 79 80 81 82 83 84 85  | Next Page >

  • Best practice to pass a value from pop over control on iPad.

    - by Tattat
    It is an iPad app based on SDK 3.2. I have a MainUIView, that is subclass from UIView, it have a UIButton and a UILabel. When user press the UIButton, the pop over control will be appeared with a table view. When the user select a cell from the table view, the UILabel changes content base on the user click, and the pop up table view will disappear. The question is, how can I pass the "selected cell" to the UILabel. I am thinking making a "middle man" object. When the user click the UIButton, and the "middle man" will pass to the table. When the cell is selected, the "middle man" will store the idx, and call the UILabel change content from the value of "middle man". But I think it is pretty complex to implement, is there any easier way to implement it? thz u.

    Read the article

  • Is it possible to get an NSView to pass rightMouseDown: to the next responder without subclassing?

    - by Benedict Cohen
    I have a view which contains a few subviews: mainView subViewA subViewB SubViewC mainView is an NSView constructed from a nib and is controlled with an NSViewController subclass. The subviews are standard views such as NSTextField and NSImageView and are configured to be non-editable. I want mainView to receive rightMouseDown: even when the event is triggered in one of the subviews. The default implementation of rightMouseDown: in NSResponder passes the event to the next responder, but NSView changes the default behaviour and does not pass it to the next responder. I could subclass all of the subviews but this doesn't seem like a very elegant or maintainable solution. How can I get the subviews to pass rightMouseDown: messages to the next responder without subclassing all of the subviews?

    Read the article

  • vSphere ESX 5.5 hosts cannot connect to NFS Server

    - by Gerald
    Summary: My problem is I cannot use the QNAP NFS Server as an NFS datastore from my ESX hosts despite the hosts being able to ping it. I'm utilising a vDS with LACP uplinks for all my network traffic (including NFS) and a subnet for each vmkernel adapter. Setup: I'm evaluating vSphere and I've got two vSphere ESX 5.5 hosts (node1 and node2) and each one has 4x NICs. I've teamed them all up using LACP/802.3ad with my switch and then created a distributed switch between the two hosts with each host's LAG as the uplink. All my networking is going through the distributed switch, ideally, I want to take advantage of DRS and the redundancy. I have a domain controller VM ("Central") and vCenter VM ("vCenter") running on node1 (using node1's local datastore) with both hosts attached to the vCenter instance. Both hosts are in a vCenter datacenter and a cluster with HA and DRS currently disabled. I have a QNAP TS-669 Pro (Version 4.0.3) (TS-x69 series is on VMware Storage HCL) which I want to use as the NFS server for my NFS datastore, it has 2x NICs teamed together using 802.3ad with my switch. vmkernel.log: The error from the host's vmkernel.log is not very useful: NFS: 157: Command: (mount) Server: (10.1.2.100) IP: (10.1.2.100) Path: (/VM) Label (datastoreNAS) Options: (None) cpu9:67402)StorageApdHandler: 698: APD Handle 509bc29f-13556457 Created with lock[StorageApd0x411121] cpu10:67402)StorageApdHandler: 745: Freeing APD Handle [509bc29f-13556457] cpu10:67402)StorageApdHandler: 808: APD Handle freed! cpu10:67402)NFS: 168: NFS mount 10.1.2.100:/VM failed: Unable to connect to NFS server. Network Setup: Here is my distributed switch setup (JPG). Here are my networks. 10.1.1.0/24 VM Management (VLAN 11) 10.1.2.0/24 Storage Network (NFS, VLAN 12) 10.1.3.0/24 VM vMotion (VLAN 13) 10.1.4.0/24 VM Fault Tolerance (VLAN 14) 10.2.0.0/24 VM's Network (VLAN 20) vSphere addresses 10.1.1.1 node1 Management 10.1.1.2 node2 Management 10.1.2.1 node1 vmkernel (For NFS) 10.1.2.2 node2 vmkernel (For NFS) etc. Other addresses 10.1.2.100 QNAP TS-669 (NFS Server) 10.2.0.1 Domain Controller (VM on node1) 10.2.0.2 vCenter (VM on node1) I'm using a Cisco SRW2024P Layer-2 switch (Jumboframes enabled) with the following setup: LACP LAG1 for node1 (Ports 1 through 4) setup as VLAN trunk for VLANs 11-14,20 LACP LAG2 for my router (Ports 5 through 8) setup as VLAN trunk for VLANs 11-14,20 LACP LAG3 for node2 (Ports 9 through 12) setup as VLAN trunk for VLANs 11-14,20 LACP LAG4 for the QNAP (Ports 23 and 24) setup to accept untagged traffic into VLAN 12 Each subnet is routable to another, although, connections to the NFS server from vmk1 shouldn't need it. All other traffic (vSphere Web Client, RDP etc.) goes through this setup fine. I tested the QNAP NFS server beforehand using ESX host VMs atop of a VMware Workstation setup with a dedicated physical NIC and it had no problems. The ACL on the NFS Server share is permissive and allows all subnet ranges full access to the share. I can ping the QNAP from node1 vmk1, the adapter that should be used to NFS: ~ # vmkping -I vmk1 10.1.2.100 PING 10.1.2.100 (10.1.2.100): 56 data bytes 64 bytes from 10.1.2.100: icmp_seq=0 ttl=64 time=0.371 ms 64 bytes from 10.1.2.100: icmp_seq=1 ttl=64 time=0.161 ms 64 bytes from 10.1.2.100: icmp_seq=2 ttl=64 time=0.241 ms Netcat does not throw an error: ~ # nc -z 10.1.2.100 2049 Connection to 10.1.2.100 2049 port [tcp/nfs] succeeded! The routing table of node1: ~ # esxcfg-route -l VMkernel Routes: Network Netmask Gateway Interface 10.1.1.0 255.255.255.0 Local Subnet vmk0 10.1.2.0 255.255.255.0 Local Subnet vmk1 10.1.3.0 255.255.255.0 Local Subnet vmk2 10.1.4.0 255.255.255.0 Local Subnet vmk3 default 0.0.0.0 10.1.1.254 vmk0 VM Kernel NIC info ~ # esxcfg-vmknic -l Interface Port Group/DVPort IP Family IP Address Netmask Broadcast MAC Address MTU TSO MSS Enabled Type vmk0 133 IPv4 10.1.1.1 255.255.255.0 10.1.1.255 00:50:56:66:8e:5f 1500 65535 true STATIC vmk0 133 IPv6 fe80::250:56ff:fe66:8e5f 64 00:50:56:66:8e:5f 1500 65535 true STATIC, PREFERRED vmk1 164 IPv4 10.1.2.1 255.255.255.0 10.1.2.255 00:50:56:68:f5:1f 1500 65535 true STATIC vmk1 164 IPv6 fe80::250:56ff:fe68:f51f 64 00:50:56:68:f5:1f 1500 65535 true STATIC, PREFERRED vmk2 196 IPv4 10.1.3.1 255.255.255.0 10.1.3.255 00:50:56:66:18:95 1500 65535 true STATIC vmk2 196 IPv6 fe80::250:56ff:fe66:1895 64 00:50:56:66:18:95 1500 65535 true STATIC, PREFERRED vmk3 228 IPv4 10.1.4.1 255.255.255.0 10.1.4.255 00:50:56:72:e6:ca 1500 65535 true STATIC vmk3 228 IPv6 fe80::250:56ff:fe72:e6ca 64 00:50:56:72:e6:ca 1500 65535 true STATIC, PREFERRED Things I've tried/checked: I'm not using DNS names to connect to the NFS server. Checked MTU. Set to 9000 for vmk1, dvSwitch and Cisco switch and QNAP. Moved QNAP onto VLAN 11 (VM Management, vmk0) and gave it an appropriate address, still had same issue. Changed back afterwards of course. Tried initiating the connection of NAS datastore from vSphere Client (Connected to vCenter or directly to host), vSphere Web Client and the host's ESX Shell. All resulted in the same problem. Tried a path name of "VM", "/VM" and "/share/VM" despite not even having a connection to server. I plugged in a linux system (10.1.2.123) into a switch port configured for VLAN 12 and tried mounting the NFS share 10.1.2.100:/VM, it worked successfully and I had read-write access to it I tried disabling the firewall on the ESX host esxcli network firewall set --enabled false I'm out of ideas on what to try next. The things I'm doing differently from my VMware Workstation setup is the use of LACP with a physical switch and a virtual distributed switch between the two hosts. I'm guessing the vDS is probably the source of my troubles but I don't know how to fix this problem without eliminating it.

    Read the article

  • Smoothwall Express interface issues

    - by Timbermar
    I have a SmoothWall Express box that is currently configured with a Green and Purple interface. Both interfaces are in the same /24 subnet (which seems odd to me). The green interface (address of .254) has a DHCP server that is pushing addresses from .1 to .100 and the purple interface (.253) is pushing addresses from .101 to .120. Every machine here is trusted, and as such is connected to the green interface via a wired connection or wireless APs. Nothing is connected at all (port is physically empty, traffic graphs show no activity) to the purple interface. However, every machine here is pulling addresses from the purple interface. So the question boils down to, how do I remove/stop my machines from pulling from the purple dhcp interface? Also, shouldn't the purple interface (if we were using it for guest Wifi or something) be on a different subnet (i.e. 192.168.100.0/24 instead of 192.168.1.0/24 with all the trusted machines)?

    Read the article

  • Multiple Subnets on home network... would this work?

    - by rockinthesixstring
    We are looking at renting out the basement suit in our home and want to offer internet as part of the package. I however do not want the downstairs tennent to have access to our network (home office = private data). We currently have a pfsense firewall as our gateway and a Windows Server 2003 box is doing our primary DHCP (192.168.0.0/24) and DNS. Here's what I'd like to do... I'd like to setup another subnet on the DHCP server (192.168.1.0/24), and hook in another wireless router (as access point only) and address it as 192.168.1.1... from there the router will hook into our primary switch and then out through the firewall. Will Server 2003 (If I add a 192.168.1.x/24 IP to the nic) serve DHCP to the devices that connect to the new router, and will it isolate that from our network? Thanks in advance... I'm very new to multiple subnets.

    Read the article

  • locate doesn't find all the files it should

    - by neubert
    I type in locate gmp.h at the prompt and get the following: /usr/src/linux-headers-3.13.0-24/include/linux/igmp.h /usr/src/linux-headers-3.13.0-24/include/uapi/linux/igmp.h /usr/src/linux-headers-3.13.0-24-generic/include/linux/igmp.h But when I do ls /usr/include/x86-64-linux-gnu/ I see this: a.out.h asm bits c++ fpu_control.h gmp.h gnu ieee754.h sys Why isn't locate locating /usr/include/x86-64-linux-gnu/gmp.h? edit: ls -l /usr/include/x64-64-linux-gnu/gmp.h says this: ls: cannot access /usr/include/x64-64-linux-gnu/gmp.h: No such file or diretory Why would ls /usr/include/x86-64-linux-gnu/ say it exists when ls -l /usr/include/x64-64-linux-gnu/gmp.h says it doesn't? A screenshot:

    Read the article

  • Lot of Multicast traffic on LAN

    - by Nel
    Recently the whole network at work is being hit by multicast traffic originating on the LAN itself. I did some investigating and the service which seems to be responsible is ws-discovery. I have attached a screenshot of wireshark capturing the traffic. I have tried shutting down the source machine from which it was originating, but the multicast traffic still seems to be present in the network. My network topology 2 subnets - 10.10.10.0/24 and 10.20.10.0/24. Gateway is a debian system. We have 3 switches for 3 floors. They are all unmanaged Dlink 24-port switches. Multicast blocking at switch level is out of the question. Any solutions? :(

    Read the article

  • Strange email coming from/to my computer

    - by Micah
    I'm running smtp4dev on my machine to trap anything going in/out of my computer on port 25 for testing purposes. Every so often this email gets trapped and I have no idea what it's from. I have Microsoft Security Essentials running on my machine and it hasn't identified and viruses or anything so I'm not sure what's going on. Here's the content of the message: Received: from [125.180.72.4] by 173.162.7.130 SMTP id O2Ncv62Ghig1vR for <[email protected]>; Fri, 24 Jun 2011 20:36:15 +0200 Received: from [125.180.72.4] by 173.162.7.130 SMTP id O2Ncv62Ghig1vR for <[email protected]>; Fri, 24 Jun 2011 20:36:15 +0200 Message-ID: <[email protected]> From: "" <[email protected]> To: <[email protected]> Subject: BC_173.162.7.130 Date: Fri, 24 Jun 11 20:36:15 GMT MIME-Version: 1.0 Content-Type: multipart/alternative; boundary="----=_NextPart_000_000D_01C2CC60.49F4EC70"

    Read the article

  • How to pass the structure to a function in C++ defined in another class?

    - by Dany
    I have a class Con as this:- class Con { public: struct MachineList { BSTR AccountId; BSTR MachineId; BSTR Make; char* Make1; BSTR Model; char* Model1; BSTR SerialNumber; BSTR IpAddress; char* IpAddress1; BSTR Port; int Port1; BSTR LocationCode; } machinelist[100] ; int w; } ; i created an object of Con class as Con m_con; I have another class Test class Test { public: void fun();//i want to pass the object of the structure that i created in Con //what arguments should i pass in fun function? };

    Read the article

  • Ubuntu Server UFW NAT Issues

    - by William Fleming
    *nat :POSTROUTING ACCEPT [0:0] -A POSTROUTING -s 10.8.0.0/24 -o eth0 -j MASQUERADE -A ufw-before-input -i tun0 -j ACCEPT -A ufw-before-output -i tun0 -j ACCEPT -A ufw-before-forward -s 10.8.0.0/24 -j ACCEPT -A ufw-before-forward -d 10.8.0.0/24 -j ACCEPT This input into my before.rules file stops me being able to ping the outside world. Before its fine i can ping google.co.uk after cant get out. Is there something wrong in my syntax here or what is the issue...? Im just trying to NAT my VPN so i can get internet access. Any thoughts would be greatly appreciated. Thanks William

    Read the article

  • Wireless Keyboard/Mouse: Should batteries be removed when not in use?

    - by abel
    I recently bought a Logitech Wireless Keyboard and mouse. I use it almost daily but for a couple of hours only. The keyboard has 2 AAA batteries and the mouse has 1 AA battery. The box mentions that the keyboard has a 24 month battery life and the mouse has a 5 month battery life. Should I keep the batteries in the keyboard/mouse, when they are not in use?Is it safe? Does the battery life mean 24 months of continuous usage or 24 months of average usage?

    Read the article

  • How to forward UDP and TCP traffic from one IP to another

    - by Rishabh Agnihotri
    Well i have a server with two LAN Card Installed.I have a server in U.S and one in India.I have created a GRE tunnel to route all traffic from U.S Server to my Indian Server.My Traffic has UDP,TCP,HTTP,etc Traffic.Now i have two LAN Card on my Indian Server.Well i have configured two IPs on the system for some of my needs on the system.One is a /30 and another is a /24.Well now i want the /30 IP to talk to my /24 IP.Lets take a e.g the IPs are 180.151.130.34 - /30 and 103.243.19.254 -/24 I want to forward all the TCP,UDP,HTTP,etc like traffic coming to 180.151.130.34 to 103.243.19.254.In the sense i want to make them talk to each other in a way if a TCP/UDP Packet comes to 180.151.130.34 it should be forwarded to 103.243.19.254 and then that packet is sent back by 103.243.19.254 to 180.151.130.34.I am not able to configure this part.Can anyone tell me step by step how to do so? Well i forgot to specify i am using Windows Server 2008. Any help would be greatly appreciated.Thanks in advance.

    Read the article

  • Cisco, How to do a subnetting scheme using VLSM and RIP-2?

    - by Andrei T. Ursan
    I'm studying for my CCNA exam and I have to create a VLSM scheme using RIP-2 for the following requirements: (this is an exercise) Use the class C network 192.168.1.0 network for your point-to-point connections Using the Class A network 10.0.0.0, plan for the following number of hosts in each location: New York: 1000 Chicago: 500 Los Angeles: 1000 On the LAN and point-to-point connections, select subnet masks that use the smallest ranges of IP addresses possible given the above requirements. In all cases, use the lowest possible subnet numbers. Subnet zero is allowed. My guess is the following: New York: S0/0 192.168.1.1 /24 Fa0/0 10.1.0.1 netmask 255.255.248.0 - because we need 1000 hosts Chicago: S0/0 192.168.1.2 /24 Fa0/0 10.2.0.1 netmask 255.255.252.0 (for 500 hosts) Los Angeles: S0/0 192.168.2.3 /24 Fa0/0 10.3.0.1 netmask 255.255.248.0 (for 1000 hosts) Is this a good configuration? I'm reading the CCNA book but not everything is very clear, so I said to do some exercises... Thank you!

    Read the article

  • Only One GPU Detected in the Nvidia Quadra NVS 450

    - by Kyle Brandt
    I just built myself an new workstation and now only 2 of 3 monitors are working. I built the nvidia driver by downloading it and installing with ./Nvidia... Before when I ran nvidia-settings I saw two GPUs listed but now I only see one. Xorg Config (Not sure how I ended up with 3 devices in there): # nvidia-settings: X configuration file generated by nvidia-settings # nvidia-settings: version 256.35 (buildmeister@builder101) Wed Jun 16 19:25:39 PDT 2010 Section "ServerLayout" # Removed Option "Xinerama" "1" Identifier "Layout0" Screen 0 "Screen0" 0 0 Screen 1 "Screen1" RightOf "Screen0" InputDevice "Keyboard0" "CoreKeyboard" InputDevice "Mouse0" "CorePointer" Option "Xinerama" "0" EndSection Section "Files" EndSection Section "InputDevice" # generated from default Identifier "Mouse0" Driver "mouse" Option "Protocol" "auto" Option "Device" "/dev/psaux" Option "Emulate3Buttons" "no" Option "ZAxisMapping" "4 5" EndSection Section "InputDevice" # generated from default Identifier "Keyboard0" Driver "kbd" EndSection Section "Monitor" # HorizSync source: edid, VertRefresh source: edid Identifier "Monitor0" VendorName "Unknown" ModelName "DELL E207WFP" HorizSync 30.0 - 83.0 VertRefresh 56.0 - 75.0 Option "DPMS" EndSection Section "Monitor" # HorizSync source: edid, VertRefresh source: edid Identifier "Monitor1" VendorName "Unknown" ModelName "DELL E207WFP" HorizSync 30.0 - 83.0 VertRefresh 56.0 - 75.0 Option "DPMS" EndSection Section "Monitor" # HorizSync source: edid, VertRefresh source: edid Identifier "Monitor2" VendorName "Unknown" ModelName "DELL E207WFP" HorizSync 30.0 - 83.0 VertRefresh 56.0 - 75.0 Option "DPMS" EndSection Section "Device" Identifier "Device0" Driver "nvidia" VendorName "NVIDIA Corporation" BoardName "Quadro NVS 450" BusID "PCI:6:0:0" EndSection Section "Device" Identifier "Device1" Driver "nvidia" VendorName "NVIDIA Corporation" BoardName "Quadro NVS 450" BusID "PCI:5:0:0" EndSection Section "Device" Identifier "Device2" Driver "nvidia" VendorName "NVIDIA Corporation" BoardName "Quadro NVS 450" BusID "PCI:3:0:0" EndSection Section "Screen" # Removed Option "TwinView" "0" # Removed Option "metamodes" "DFP-0: nvidia-auto-select +0+0" # Removed Option "metamodes" "DFP-0: nvidia-auto-select +0+275, DFP-3: nvidia-auto-select +1680+0" Identifier "Screen0" Device "Device0" Monitor "Monitor0" DefaultDepth 24 Option "TwinView" "1" Option "TwinViewXineramaInfoOrder" "DFP-3" Option "metamodes" "DFP-0: nvidia-auto-select +0+0, DFP-3: nvidia-auto-select +1680+0" SubSection "Display" Depth 24 EndSubSection EndSection Section "Screen" # Removed Option "metamodes" "DFP-3: nvidia-auto-select +0+0" Identifier "Screen1" Device "Device1" Monitor "Monitor1" DefaultDepth 24 Option "TwinView" "0" Option "metamodes" "nvidia-auto-select +0+0" SubSection "Display" Depth 24 EndSubSection EndSection Section "Screen" Identifier "Screen2" Device "Device2" Monitor "Monitor2" DefaultDepth 24 Option "TwinView" "0" Option "metamodes" "nvidia-auto-select +0+0" SubSection "Display" Depth 24 EndSubSection EndSection lscpi: 00:00.0 Host bridge: Intel Corporation 5520/5500/X58 I/O Hub to ESI Port (rev 13) 00:01.0 PCI bridge: Intel Corporation 5520/5500/X58 I/O Hub PCI Express Root Port 1 (rev 13) 00:02.0 PCI bridge: Intel Corporation 5520/5500/X58 I/O Hub PCI Express Root Port 2 (rev 13) 00:03.0 PCI bridge: Intel Corporation 5520/5500/X58 I/O Hub PCI Express Root Port 3 (rev 13) 00:10.0 PIC: Intel Corporation 5520/5500/X58 Physical and Link Layer Registers Port 0 (rev 13) 00:10.1 PIC: Intel Corporation 5520/5500/X58 Routing and Protocol Layer Registers Port 0 (rev 13) 00:11.0 PIC: Intel Corporation 5520/5500 Physical and Link Layer Registers Port 1 (rev 13) 00:11.1 PIC: Intel Corporation 5520/5500 Routing & Protocol Layer Register Port 1 (rev 13) 00:13.0 PIC: Intel Corporation 5520/5500/X58 I/O Hub I/OxAPIC Interrupt Controller (rev 13) 00:14.0 PIC: Intel Corporation 5520/5500/X58 I/O Hub System Management Registers (rev 13) 00:14.1 PIC: Intel Corporation 5520/5500/X58 I/O Hub GPIO and Scratch Pad Registers (rev 13) 00:14.2 PIC: Intel Corporation 5520/5500/X58 I/O Hub Control Status and RAS Registers (rev 13) 00:15.0 PIC: Intel Corporation 5520/5500/X58 Trusted Execution Technology Registers (rev 13) 00:1a.0 USB Controller: Intel Corporation 82801JI (ICH10 Family) USB UHCI Controller #4 00:1a.1 USB Controller: Intel Corporation 82801JI (ICH10 Family) USB UHCI Controller #5 00:1a.2 USB Controller: Intel Corporation 82801JI (ICH10 Family) USB UHCI Controller #6 00:1a.7 USB Controller: Intel Corporation 82801JI (ICH10 Family) USB2 EHCI Controller #2 00:1b.0 Audio device: Intel Corporation 82801JI (ICH10 Family) HD Audio Controller 00:1c.0 PCI bridge: Intel Corporation 82801JI (ICH10 Family) PCI Express Root Port 1 00:1c.1 PCI bridge: Intel Corporation 82801JI (ICH10 Family) PCI Express Port 2 00:1c.3 PCI bridge: Intel Corporation 82801JI (ICH10 Family) PCI Express Root Port 4 00:1c.4 PCI bridge: Intel Corporation 82801JI (ICH10 Family) PCI Express Root Port 5 00:1d.0 USB Controller: Intel Corporation 82801JI (ICH10 Family) USB UHCI Controller #1 00:1d.1 USB Controller: Intel Corporation 82801JI (ICH10 Family) USB UHCI Controller #2 00:1d.2 USB Controller: Intel Corporation 82801JI (ICH10 Family) USB UHCI Controller #3 00:1d.7 USB Controller: Intel Corporation 82801JI (ICH10 Family) USB2 EHCI Controller #1 00:1e.0 PCI bridge: Intel Corporation 82801 PCI Bridge (rev 90) 00:1f.0 ISA bridge: Intel Corporation 82801JIR (ICH10R) LPC Interface Controller 00:1f.2 IDE interface: Intel Corporation 82801JI (ICH10 Family) 4 port SATA IDE Controller #1 00:1f.3 SMBus: Intel Corporation 82801JI (ICH10 Family) SMBus Controller 00:1f.5 IDE interface: Intel Corporation 82801JI (ICH10 Family) 2 port SATA IDE Controller #2 01:00.0 IDE interface: Device 1b4b:91a3 (rev 11) 02:00.0 USB Controller: NEC Corporation Device 0194 (rev 03) 03:00.0 PCI bridge: nVidia Corporation PCI express bridge for Quadro Plex S4 / Tesla S870 / Tesla S1070 (rev a3) 04:00.0 PCI bridge: nVidia Corporation PCI express bridge for Quadro Plex S4 / Tesla S870 / Tesla S1070 (rev a3) 04:02.0 PCI bridge: nVidia Corporation PCI express bridge for Quadro Plex S4 / Tesla S870 / Tesla S1070 (rev a3) 05:00.0 3D controller: nVidia Corporation G98 [Quadro NVS 450] (rev a1) 06:00.0 VGA compatible controller: nVidia Corporation G98 [Quadro NVS 450] (rev a1) 08:00.0 SATA controller: JMicron Technology Corp. JMB362/JMB363 Serial ATA Controller (rev 02) 08:00.1 IDE interface: JMicron Technology Corp. JMB362/JMB363 Serial ATA Controller (rev 02) 09:00.0 SATA controller: JMicron Technology Corp. JMB362/JMB363 Serial ATA Controller (rev 03) 09:00.1 IDE interface: JMicron Technology Corp. JMB362/JMB363 Serial ATA Controller (rev 03) 0a:00.0 Ethernet controller: Realtek Semiconductor Co., Ltd. RTL8111/8168B PCI Express Gigabit Ethernet controller (rev 06) 0b:06.0 FireWire (IEEE 1394): Texas Instruments TSB43AB23 IEEE-1394a-2000 Controller (PHY/Link)

    Read the article

  • ipfw to redirect traffic from port 80 and 443 to 8080

    - by user1048138
    -A PREROUTING -s 10.0.10.0/24 -p tcp -m tcp --dport 80 -j REDIRECT --to-ports 8080 -A PREROUTING -s 10.0.10.0/24 -p tcp -m tcp --dport 443 -j REDIRECT --to-ports 8080 -A POSTROUTING -s 10.0.10.0/24 -o eth0 -j MASQUERADE The above code is what I have used on linux to forward my ports to 8080, how can I do the same on a mac? I have tried test_machine:~ root# ipfw show 00666 0 0 fwd 127.0.0.1,8080 tcp from any to me dst-port 80 and its not working! any suggestions?

    Read the article

  • Default gateway is in different subnet. How to configure in RHEL6.2

    - by Dmytro Leonenko
    I have two subnets routed to my server from ISP. I have only one gateway ip. The gateway is on the same VLAN as my IP address. For example netowrk 1 is 1.0.0.0/24 and network 2 is 2.0.0.0/24. Both are routed to eth0 by my ISP. Gateway is 1.0.0.1. My host ip is 2.0.0.1/24 (eth0) So I can configure default gateway manually with ip route add default dev eth0 ip route add default via 1.0.0.1 and then internet connection works properly. How do I configure it in /etc/sysconfig/network-scripts/ifcfg-eth0 ? I tried to set GATEWAY=1.0.0.1 but it doesn't work. Tried to set GATEWAY and GATEWAYDEV in /etc/sysconfig/network and it does only what first command from listing above do.

    Read the article

  • DHCP for Multiple Subnets

    - by TheD
    So this is the current setup - essentially I would like to get my DHCP server, serving DHCP requests for two seperate subnets. Netgear DG834G acting as a modem connected to a Sonicwall Pro 2040. X0 - LAN - 192.168.1.0/24 X1 - WAN - <WAN-IP> X2 - WLAN - 192.168.10.0/24 At the moment, I have a 2008R2 server with DHCP installed, with an IP address on the 192.168.1.0/24 range handling DHCP fine for this subnet. The Sonicwall is configured correctly - anything connected to the WLAN has Full Allow to anything in the LAN, and vice versa but it will not lease an IP from my Server. I've also added another IP address to the server, so the physical NIC now has two IP's: 192.168.1.2 and 192.168.10.2 with a DHCP scope configured for each. Still no luck! Any ideas? Thanks!

    Read the article

  • Can I pass a child class to a reference of a parent class?

    - by michael
    Hi, I have a class A which takes a reference of B in its constructor. class A { public: A(B& b); } And I have a class SubB which is a child class of B: class SubB : public B { //omitted... } In my code, I create a SubB and pass it to A: SubB subB; A a(subB); But I get this compile Error: error: ‘B’ is an inaccessible base of ‘SubB’ Can I pass a reference of SubB as B? Thank you.

    Read the article

  • Only One GPU Detected in the Nvidia Quadro NVS 450

    - by Kyle Brandt
    I just built myself an new workstation and now only 2 of 3 monitors are working. I built the nvidia driver by downloading it and installing with ./Nvidia... Before when I ran nvidia-settings I saw two GPUs listed but now I only see one. Xorg Config (Not sure how I ended up with 3 devices in there): # nvidia-settings: X configuration file generated by nvidia-settings # nvidia-settings: version 256.35 (buildmeister@builder101) Wed Jun 16 19:25:39 PDT 2010 Section "ServerLayout" # Removed Option "Xinerama" "1" Identifier "Layout0" Screen 0 "Screen0" 0 0 Screen 1 "Screen1" RightOf "Screen0" InputDevice "Keyboard0" "CoreKeyboard" InputDevice "Mouse0" "CorePointer" Option "Xinerama" "0" EndSection Section "Files" EndSection Section "InputDevice" # generated from default Identifier "Mouse0" Driver "mouse" Option "Protocol" "auto" Option "Device" "/dev/psaux" Option "Emulate3Buttons" "no" Option "ZAxisMapping" "4 5" EndSection Section "InputDevice" # generated from default Identifier "Keyboard0" Driver "kbd" EndSection Section "Monitor" # HorizSync source: edid, VertRefresh source: edid Identifier "Monitor0" VendorName "Unknown" ModelName "DELL E207WFP" HorizSync 30.0 - 83.0 VertRefresh 56.0 - 75.0 Option "DPMS" EndSection Section "Monitor" # HorizSync source: edid, VertRefresh source: edid Identifier "Monitor1" VendorName "Unknown" ModelName "DELL E207WFP" HorizSync 30.0 - 83.0 VertRefresh 56.0 - 75.0 Option "DPMS" EndSection Section "Monitor" # HorizSync source: edid, VertRefresh source: edid Identifier "Monitor2" VendorName "Unknown" ModelName "DELL E207WFP" HorizSync 30.0 - 83.0 VertRefresh 56.0 - 75.0 Option "DPMS" EndSection Section "Device" Identifier "Device0" Driver "nvidia" VendorName "NVIDIA Corporation" BoardName "Quadro NVS 450" BusID "PCI:6:0:0" EndSection Section "Device" Identifier "Device1" Driver "nvidia" VendorName "NVIDIA Corporation" BoardName "Quadro NVS 450" BusID "PCI:5:0:0" EndSection Section "Device" Identifier "Device2" Driver "nvidia" VendorName "NVIDIA Corporation" BoardName "Quadro NVS 450" BusID "PCI:3:0:0" EndSection Section "Screen" # Removed Option "TwinView" "0" # Removed Option "metamodes" "DFP-0: nvidia-auto-select +0+0" # Removed Option "metamodes" "DFP-0: nvidia-auto-select +0+275, DFP-3: nvidia-auto-select +1680+0" Identifier "Screen0" Device "Device0" Monitor "Monitor0" DefaultDepth 24 Option "TwinView" "1" Option "TwinViewXineramaInfoOrder" "DFP-3" Option "metamodes" "DFP-0: nvidia-auto-select +0+0, DFP-3: nvidia-auto-select +1680+0" SubSection "Display" Depth 24 EndSubSection EndSection Section "Screen" # Removed Option "metamodes" "DFP-3: nvidia-auto-select +0+0" Identifier "Screen1" Device "Device1" Monitor "Monitor1" DefaultDepth 24 Option "TwinView" "0" Option "metamodes" "nvidia-auto-select +0+0" SubSection "Display" Depth 24 EndSubSection EndSection Section "Screen" Identifier "Screen2" Device "Device2" Monitor "Monitor2" DefaultDepth 24 Option "TwinView" "0" Option "metamodes" "nvidia-auto-select +0+0" SubSection "Display" Depth 24 EndSubSection EndSection lscpi: 00:00.0 Host bridge: Intel Corporation 5520/5500/X58 I/O Hub to ESI Port (rev 13) 00:01.0 PCI bridge: Intel Corporation 5520/5500/X58 I/O Hub PCI Express Root Port 1 (rev 13) 00:02.0 PCI bridge: Intel Corporation 5520/5500/X58 I/O Hub PCI Express Root Port 2 (rev 13) 00:03.0 PCI bridge: Intel Corporation 5520/5500/X58 I/O Hub PCI Express Root Port 3 (rev 13) 00:10.0 PIC: Intel Corporation 5520/5500/X58 Physical and Link Layer Registers Port 0 (rev 13) 00:10.1 PIC: Intel Corporation 5520/5500/X58 Routing and Protocol Layer Registers Port 0 (rev 13) 00:11.0 PIC: Intel Corporation 5520/5500 Physical and Link Layer Registers Port 1 (rev 13) 00:11.1 PIC: Intel Corporation 5520/5500 Routing & Protocol Layer Register Port 1 (rev 13) 00:13.0 PIC: Intel Corporation 5520/5500/X58 I/O Hub I/OxAPIC Interrupt Controller (rev 13) 00:14.0 PIC: Intel Corporation 5520/5500/X58 I/O Hub System Management Registers (rev 13) 00:14.1 PIC: Intel Corporation 5520/5500/X58 I/O Hub GPIO and Scratch Pad Registers (rev 13) 00:14.2 PIC: Intel Corporation 5520/5500/X58 I/O Hub Control Status and RAS Registers (rev 13) 00:15.0 PIC: Intel Corporation 5520/5500/X58 Trusted Execution Technology Registers (rev 13) 00:1a.0 USB Controller: Intel Corporation 82801JI (ICH10 Family) USB UHCI Controller #4 00:1a.1 USB Controller: Intel Corporation 82801JI (ICH10 Family) USB UHCI Controller #5 00:1a.2 USB Controller: Intel Corporation 82801JI (ICH10 Family) USB UHCI Controller #6 00:1a.7 USB Controller: Intel Corporation 82801JI (ICH10 Family) USB2 EHCI Controller #2 00:1b.0 Audio device: Intel Corporation 82801JI (ICH10 Family) HD Audio Controller 00:1c.0 PCI bridge: Intel Corporation 82801JI (ICH10 Family) PCI Express Root Port 1 00:1c.1 PCI bridge: Intel Corporation 82801JI (ICH10 Family) PCI Express Port 2 00:1c.3 PCI bridge: Intel Corporation 82801JI (ICH10 Family) PCI Express Root Port 4 00:1c.4 PCI bridge: Intel Corporation 82801JI (ICH10 Family) PCI Express Root Port 5 00:1d.0 USB Controller: Intel Corporation 82801JI (ICH10 Family) USB UHCI Controller #1 00:1d.1 USB Controller: Intel Corporation 82801JI (ICH10 Family) USB UHCI Controller #2 00:1d.2 USB Controller: Intel Corporation 82801JI (ICH10 Family) USB UHCI Controller #3 00:1d.7 USB Controller: Intel Corporation 82801JI (ICH10 Family) USB2 EHCI Controller #1 00:1e.0 PCI bridge: Intel Corporation 82801 PCI Bridge (rev 90) 00:1f.0 ISA bridge: Intel Corporation 82801JIR (ICH10R) LPC Interface Controller 00:1f.2 IDE interface: Intel Corporation 82801JI (ICH10 Family) 4 port SATA IDE Controller #1 00:1f.3 SMBus: Intel Corporation 82801JI (ICH10 Family) SMBus Controller 00:1f.5 IDE interface: Intel Corporation 82801JI (ICH10 Family) 2 port SATA IDE Controller #2 01:00.0 IDE interface: Device 1b4b:91a3 (rev 11) 02:00.0 USB Controller: NEC Corporation Device 0194 (rev 03) 03:00.0 PCI bridge: nVidia Corporation PCI express bridge for Quadro Plex S4 / Tesla S870 / Tesla S1070 (rev a3) 04:00.0 PCI bridge: nVidia Corporation PCI express bridge for Quadro Plex S4 / Tesla S870 / Tesla S1070 (rev a3) 04:02.0 PCI bridge: nVidia Corporation PCI express bridge for Quadro Plex S4 / Tesla S870 / Tesla S1070 (rev a3) 05:00.0 3D controller: nVidia Corporation G98 [Quadro NVS 450] (rev a1) 06:00.0 VGA compatible controller: nVidia Corporation G98 [Quadro NVS 450] (rev a1) 08:00.0 SATA controller: JMicron Technology Corp. JMB362/JMB363 Serial ATA Controller (rev 02) 08:00.1 IDE interface: JMicron Technology Corp. JMB362/JMB363 Serial ATA Controller (rev 02) 09:00.0 SATA controller: JMicron Technology Corp. JMB362/JMB363 Serial ATA Controller (rev 03) 09:00.1 IDE interface: JMicron Technology Corp. JMB362/JMB363 Serial ATA Controller (rev 03) 0a:00.0 Ethernet controller: Realtek Semiconductor Co., Ltd. RTL8111/8168B PCI Express Gigabit Ethernet controller (rev 06) 0b:06.0 FireWire (IEEE 1394): Texas Instruments TSB43AB23 IEEE-1394a-2000 Controller (PHY/Link)

    Read the article

  • How Do I Schedule Cron to Run at Specific intervals?

    - by Russ
    I have 6 scripts that each take about 20 minutes to run, I want to schedule cron to run the first 3 at 00, 20, and 40 on the odd hours and the second 3 at the same intervals on the even hours. How can I tell cron to do this? is it something like this: 0 2,4,6,8,10,12,14,16,18,20,22,24 * * * root Script1 20 2,4,6,8,10,12,14,16,18,20,22,24 * * * root Script2 40 2,4,6,8,10,12,14,16,18,20,22,24 * * * root Script3 0 1,3,5,7,9,11,13,17,19,21,23 * * * root Script4 20 1,3,5,7,9,11,13,17,19,21,23 * * * root Script5 40 1,3,5,7,9,11,13,17,19,21,23 * * * root Script6

    Read the article

  • What's required to enable communication between two IP ranges located behind one switch?

    - by Eric3
    Within our co-located networking closet, we have control over two ranges of 254 addresses, e.g. 64.123.45.0/24 and 65.234.56.0/24. The problem is, if a host has only one IP address, or a block of addresses in only one range, it can't contact any of the addresses in the other subnet. All of our hosts use our hosting provider's respective gateway, e.g. 64.123.45.1 or 65.234.56.1 A host on the 64.123.45.0/24 range can contact the 65.234.56.1 gateway and vice-versa Everything in our closet is connected to an HP ProCurve 2810 (a Layer 2-only switch), which connects through a Juniper NetScreen-25 firewall to the outside world What can I do to enable communication between the two ranges? Is there some settings I can change, or do I need better networking equipment?

    Read the article

  • How can I pass a Visual Studio project's assembly version to another project for use in a post-build

    - by Coder7862396
    I have a solution with 2 projects: My Application 1.2.54 (C# WinForms) My Application Setup 1.0.0.0 (WiX Setup) I would like to add a post-build event to the WiX Setup project to run a batch file and pass it a command line parameter of My Application's assembly version number. The code may look something like this: CALL MyBatchFile.bat "$(fileVersion.ProductVersion($(var.My Application.TargetPath)))" But this results in the following error: Unhandled Exception:The expression """.My Application" cannot be evaluated. Method 'System.String.My Application' not found. C:\My Application\My Application Setup\My Application Setup.wixproj Error: The expression """.My Application" cannot be evaluated. Method 'System.String.My Application' not found. C:\My Application\My Application Setup\My Application Setup.wixproj I would like to be able to pass "1.2.54" to MyBatchFile.bat somehow.

    Read the article

< Previous Page | 74 75 76 77 78 79 80 81 82 83 84 85  | Next Page >