  • Installing VMware ESXi 4.0 on Dell 1950: Cannot open vmkboot.gz

    - by rlandster
    I am trying to install VMware ESXi 4.0.0 U1 on a Dell 1950 server via a bootable CD-ROM. I keep getting this error right at the start: Cannot open vmkboot.gz I checked that the CD-ROM drive is not to blame by installing Debian Etch using that drive. I tried several different versions of ESXi (3.5, 3.5 Dell edition, 4.0 Dell edition) and they all give me an error at the same place. I also tried installing from a USB "thumb" drive but got the same error. I checked with the VMware HCL (Hardware Compatibility List) and the Dell 1950 is listed as being compatible. Here are some server details: Two 1.6 GHz Xeon 5110 CPUs (ID: 06-0F-B) BIOS version 2.2.6 Any ideas on what might be the issue?

    Read the article

  • Using a non-validated SED on a Dell R720

    - by a coder
    We were given a Dell R720 a couple years ago, and the machine currently has standard 300GB 3.5" SAS 15k drives. Our RAID controller is a Perc H710. We need to update our disks to FIPS 140-2 certified SED. According to Dell, they have only one tested/validated FIPS SED for this machine/controller, but it is a 7200rpm 3.5" unit. I'm showing that Dell offers a 600GB 15k FIPS SED in 3.5" configuration (Dell part number 342-0605), but they say they haven't validated or tested to know if it works. They informed us that we would not void our warranty in using this non-validated drive. How likely is it that our R720 with H710 controller will work with the non-validated drive? Are there significant differences in how drive manufacturers build SED that would prevent them from working consistently across different controllers?

    Read the article

  • Local User & Local Admin User Server 2008

    - by Ammo
    Hi I had a test recently and one of the questions was to create a file and local user and give the local user write permission to that file. I created the local user successfully however when I went to add permission to the file it would not find the local user when name was entered correctly, and idea what could have prevented this. Secondly I was asked to create a local admin account and give full permissions to the file, to my knowledge server 2008 has a built in admin account, and neither was the server a domain controller. Could you tell me what you would do in this situation? Many Thanks!

    Read the article

  • How to use 3T SAS HDDs which aren't supported by Dell PERC 6i

    - by Sunry
    We bought several 3T SAS hard disks want to use with our Dell R710 server. But we found our R710 can't recognize the 3T hd, and then we dig out the raid card is PERC 6i which doesn't support it. Contacted with Dell that H700 and H800 support 3T hd, thought we can buy a H700 , but the SAS cable is not available in the market right now. And it seems very hard for us to change the raid card, also no suitable tools to tease the special screws. So I want to know if any other method to use these 3T hds instead of putting them in the warehouse? Can I low formatting it to 2TB, and plug it into Dell R710 to use? Or a SAS to USB adapter to use it as USB external disk? I just want to use them by Dell R710 even external.

    Read the article

  • Manage Dell workstations with OpenManage Essentials (OME)

    - by Jonathan Rioux
    How can I manage Dell workstations with OpenManage Essentials ? First, is it possible? Because iv read that only Dell servers can be managed with OME. I would like to inventory each Dell workstations I have in my environment, and be able to see their service tag with warranty expiration, etc. Or which product must I use to do this? There are so much Dell management products like OMCI, OMCC, ITA, etc!! I am so lost with all these products.

    Read the article

  • Design For Asynchronous User Interface

    - by Sohnee
    I have been working on a integration that has posed an interesting user interface conundrum that I would like suggestions for. The user interface is displayed within a third party product. The state of the interface is supplied by calls to a service I have written. There can be small delays between the actual state changing the the user interface changing due to the polling for state by the third party. When a user interacts with the user interface, requests are sent back to my application. This then affects the state and the next state poll request will update the user interface. The problem is that the delay between pressing a button and seeing the user interface update is perhaps 1 or 2 seconds and in usability testing I can see that people are clicking again before the user interface updates, thinking that they haven't properly clicked the first time. Given the constraints (we can only update the user interface via the polling mechanism - if we updated it when they clicked, the polling might return and overwrite the change causing unpredictable / undesirable results)... what can we do to make the user experience better. My current idea is to show a message for a couple of seconds so people know their click was accepted, the message would not be affected by the state polling, so wouldn't be prematurely removed / overwritten etc. I'm sure there are other ideas out there and I'm also confident someone has a better idea that I have!

    Read the article

  • SQL SERVER – Detecting guest User Permissions – guest User Access Status

    - by pinaldave
    Earlier I wrote the blog post SQL SERVER – Disable Guest Account – Serious Security Issue, and I got many comments asking questions related to the guest user. Here are the comments of Manoj: 1) How do we know if the uest user is enabled or disabled? 2) What is the default for guest user in SQL Server? Default settings for guest user When SQL Server is installed by default, the guest user is disabled for security reasons. If the guest user is not properly configured, it can create a major security issue. You can read more about this here. Identify guest user status There are multiple ways to identify guest user status: Using SQL Server Management Studio (SSMS) You can expand the database node >> Security >> Users. If you see the RED arrow pointing downward, it means that the guest user is disabled. Using sys.sysusers Here is a simple script. If you notice column dbaccess as 1, it means that the guest user is enabled and has access to the database. SELECT name, hasdbaccess FROM sys.sysusers WHERE name = 'guest' Using sys.database_principals and sys.server_permissions This script is valid in SQL Server 2005 and a later version. This is my default method recently. SELECT name, permission_name, state_desc FROM sys.database_principals dp INNER JOIN sys.server_permissions sp ON dp.principal_id = sp.grantee_principal_id WHERE name = 'guest' AND permission_name = 'CONNECT' Using sp_helprotect Just run the following stored procedure which will give you all the permissions associated with the user. sp_helprotect @username = 'guest' Disable Guest Account REVOKE CONNECT FROM guest Additionally, the guest account cannot be disabled in master and tempdb; it is always enabled. There is a special need for this. Let me ask a question back at you: In which scenario do you think this will be useful to keep the guest, and what will the additional configuration go along with the scenario? Note: Special mention to Imran Mohammed for being always there when users need help. Reference: Pinal Dave (http://blog.sqlauthority.com) Filed under: PostADay, SQL, SQL Authority, SQL Query, SQL Security, SQL Server, SQL Tips and Tricks, T SQL, Technology

    Read the article

  • Exchange accidentally forwards sent mails from one User to another User's Inbox

    - by Das Butterschnitzel
    Like the Topic says: Our Exchange Server accidentally forwards sent mails from one User to another User's Inbox. The sent mails are mostly to Outbound Adresses and they where successfully delivered but all those sent Mails are accidentally forwarded into our Info Mail account. There are no Outlook rules defined and the forward routing in exchange is not used, for such things. I really don´t know the cause of the problem and i don´t know where I have to look, because I´m new to exchange...

    Read the article

  • Dell e4300 Random Beeps

    - by Mikey.B
    I’ve noticed that my Dell e4300 Laptop will randomly beep every now and then. The symptoms are virtually identical to the issue described here: http://en.community.dell.com/support-forums/laptop/f/3518/t/19314488.aspx Any ideas why? I thought it might be related to hard drive activity so I downloaded the western digital disk utility and all tests check out fine. It’s not a big deal and it only beeps once every few days. I just want to make sure there isn’t a larger problem looming. =) -M

    Read the article

  • No win 7 users available for login after dell datasafe factory reset

    - by user897052
    I created install discs using the Dell datasafe 2.0 backup utility in order to re-install windows on a friend's laptop (dell inspiron n5110). I ran the discs to do a factory reset. after the whole process, it booted, started loading windows 7, displayed the messages "setup is preparing your computer for first use" and "setup is checking video performance," and showed the login screen. However, there don't seem to be any active users on the machine - I opened a command prompt window to check the users on the machine. Using the command prompt (again, from the login window), i activated/enabled the administrator account, and even created another admin account, and upon logging in received several errors, couldn't load any mmc's, etc. any help would be appreciated.

    Read the article

  • Dell Media Direct is rebooting my machine when it goes into sleep mode

    - by wsanville
    I've got a Dell Studio 1535 laptop, which shipped w/ Vista 32-bit. I've since formatted and installed Windows 7 64-bit. Everything has been fine for months, but recently, every time I leave my machine unattended and it goes to sleep, it wakes with the Dell Media Direct splash screen, and then goes to the "Windows was not shut down properly..." dialog that asks if you want to boot safe mode/start Windows normally/etc. The stupid button is also stuck on currently, but even when it is off, the problem still occurs. From the searching I've done, I've learned that the program is installed on its own partition, but I'm fairly certain I formatted everything. See screenie of my partitions: How can I stop the madness? Update: I've removed the 39 MB OEM Partition and it is still happening.

    Read the article

  • 3rd monitor with Dell Precision 490

    - by Animesh Kumar
    I am trying to go for a 3 monitor setup on my workstation, but need some information before I can invest in a new graphics card and 2 monitors. Would be glad to get some help here: I have a Dell Precision 490 workstation with Nvidia Quadro FX 4500 graphics card (PCI-E 16) on it. It has 2 DVI-D ports that can support 2 monitors upto 2560x1600 resolution. For the third monitor, I was looking at Nvidia NVS 295 card, however I am not sure if it is physically possible to hook another card to the motherboard. Here is the spec of Precision 490: http://www.dell.com/downloads/global/products/precn/en/spec_precn_490_en.pdf Can I attach NVS 295 to it? If not, what options do I have?

    Read the article

  • Install Win7 on Dell XPS1730: CD Driver missing

    - by Mies75
    Vista crashed on my DELL XPS 1730 laptop. Again. I deleted the RAID array, created a new one and started to install Window 7 from DVD. During the initial phase of installation the setup pop ups this: Load Driver: A required CD/DVD device driver is missing... I can then insert other media to load the drivers, but it can't find any. I checked the DELL site for drivers but I can only find firmware for the drive. Which driver do I need, and where can I download it?

    Read the article

  • Num Lock of laptop working strangely [Dell Vostro 1710]

    - by Bakhtiyor
    My laptop model is Dell Vostro 17" and it has numeric keypad. The problem is that its Num Lock key works very strange. Sometimes when I press it the information led of Num Lock activates, but sometimes when I try to activate numeric keypad it refuses and this led doesn't activate and therefore numeric keypad doesn't work at all. Does it mean that I need to change my keyboard at all? In addition Esc key doesn't work for a long time. I think the main reason for that is my son (2year old) who started playing with my laptop from his 1st year. If I need to change the keyboard where can I buy it for a good price, because in Dell I think when I called them 2-3 months ago they offered me keyboard for about more then 50Euros. Currently I live in Spain. Thanks.

    Read the article

  • Dell Media Direct is rebooting my machine when it goes into sleep mode

    - by wsanville
    I've got a Dell studio 1535 laptop, which shipped w/ Vista 32 bit. I've since formatted and installed Win 7 64. Everything has been fine for months, but recently, every time I leave my machine unattended and it goes to sleep, it wakes with the Dell Media Direct splash screen, and then goes to the "Windows was not shut down properly..." dialog that asks if you want to boot safe mode/start Windows normally/etc. The stupid button is also stuck on currently, but even when it is off, the problem still occurs. From the searching I've done, I've learned that the program is installed on its own partition, but I'm fairly certain I formatted everything (see screenie of my partitions: http://www.engr.uconn.edu/~wsj05001/misc/partitions.png). How can I stop the madness?

    Read the article

  • Impossible do find motherboard drivers to Dell Dimension 3000

    - by Masziej
    Hello, I recently formatet and reinstalled XP on my girlfriends computer. Ive had this computer since 2001, never formatet it, until now =) Anyway the problem is that i cant find any drivers for the motherboard (integrated audio, video and ethernet). as i said its an old ass Dell. Cant remember if I got any cds along with it. Even if i did theyre gone a long time ago. So, I ran CPUZ and got this: --Motherboard-- Dell Computer Corp. Model 0K8980 And started googling. But didnt find any drivers. Still cant So im asking for a little help here. I really need to get the computer going before she wants a new one :D And yes i have looked on dells homesite, but they dont seem to wanna host drivers for their old stuff

    Read the article

  • How to turn ON bluetooth in Dell Inspiron?

    - by ykombinator
    I bought a new Dell Inspiron laptop a month ago. The company had pre-installed all the required software in my laptop. As such, the bluetooth used to be switched ON whenever I switched on my machine. However, a few days later, the bluetooth stopped working. I re-started the Laptop and it was ON! Now I am facing this problem very frequently. As such, the wi-fi connection doesn't work unless the bluetooth is switched ON. The bluetooth turns ON after a few re-boots and sometimes doesn't turn ON for many days. Does anybody know any trick to keep the bluetooth ON everytime I switch ON my machine. P.S: The Dell manual did not help.

    Read the article

  • Impossible do find motherboard drivers to and old Dell computer

    - by Masziej
    Hello, I recently formatet and reinstalled XP on my girlfriends computer. Ive had this computer since 2001, never formatet it, until now =) Anyway the problem is that i cant find any drivers for the motherboard (integrated audio, video and ethernet). as i said its an old ass Dell. Cant remember if I got any cds along with it. Even if i did theyre gone a long time ago. So, I ran CPUZ and got this: --Motherboard-- Dell Computer Corp. 0K8980 And started googling. But didnt find any drivers. Still cant So im asking for a little help here. I really need to get the computer going before she wants a new one :D And yes i have looked on dells homesite, but they dont seem to wanna host drivers for their old stuff

    Read the article

  • Flickering/Flashing screen problem related to keyboard

    - by LeandroCR
    This will seems quite bizarre but that's a huge problem for me, I'm facing it for a long time since Ubuntu 12.04. My Ubuntu/Linux Mint/Debian (Unity/Gnome) always starts flickering after using the computer for a while, I always thought this had something to do with the video board. I have an Vostro 3550 (Radeon 6xxx/Intel Onboard). First I realized that when I was navigating trough an website, when i selected with the mouse a combo, the combo closed it self automatically then the screen starts flickering. The i realized when i was trying to make the login in the terminal (crtl + alt + f1) a strange character appears, like: ^@ repeatedly. When i keep CRTL pressed the system never flickers! I have absolutely no problem using Windows. What can i do? There is no such thing as Keyboard driver on Dell Support. I would love to use Ubuntu only, but this is very annoying. Problem happens on Ubuntu 12.04, .10 and 13.04 Linux Mint 15 (Cinnamon) Debian Live with Gnome

    Read the article

  • Finding out why Dell Controler is Degraded

    - by Kyle Brandt
    I installed open manage on a couple of my PE 2950s for snmp monitoring of the RAID. All the checks seem to come back okay except for controllerState: [root@aMachine ~]# snmpwalk -v 2c -c bestNotToPostPasswords myMachine -m +StorageManagement-MIB controllerstate StorageManagement-MIB::controllerState.1 = INTEGER: degraded(6) Other checks seems to indicate the battery, LD, and physicals disks are all good unless I missing something. Can anyone tell if I am missing something or neglecting something import in my RAID monitoring/understanding? I get degraded for both these servers I have set up. A walk of the entire storage management tree for on of them: StorageManagement-MIB::softwareVersion.0 = STRING: "3.2.0" StorageManagement-MIB::globalStatus.0 = INTEGER: warning(2) StorageManagement-MIB::softwareManufacturer.0 = STRING: "Dell Inc." StorageManagement-MIB::softwareProduct.0 = STRING: "Server Administrator (Storage Management)" StorageManagement-MIB::softwareDescription.0 = STRING: "Configuration and monitoring of disk storage devices." StorageManagement-MIB::displayName.0 = STRING: "Server Administrator (Storage Management)" StorageManagement-MIB::description.0 = STRING: "Configuration and monitoring of disk storage devices." StorageManagement-MIB::agentVendor.0 = STRING: "Dell Inc." StorageManagement-MIB::agentTimeStamp.0 = INTEGER: 1273842310 StorageManagement-MIB::agentGetTimeout.0 = INTEGER: 5 StorageManagement-MIB::agentModifiers.0 = INTEGER: 0 StorageManagement-MIB::agentRefreshRate.0 = INTEGER: 300 StorageManagement-MIB::agentMibVersion.0 = STRING: "3.2" StorageManagement-MIB::agentManagementSoftwareURLName.0 = "" StorageManagement-MIB::agentGlobalSystemStatus.0 = INTEGER: nonCritical(4) StorageManagement-MIB::agentLastGlobalSystemStatus.0 = INTEGER: ok(3) StorageManagement-MIB::agentSmartThermalShutdown.0 = INTEGER: notApplicable(3) StorageManagement-MIB::controllerNumber.1 = INTEGER: 1 StorageManagement-MIB::controllerName.1 = STRING: "PERC 5/i Integrated" StorageManagement-MIB::controllerVendor.1 = STRING: "DELL" StorageManagement-MIB::controllerType.1 = INTEGER: sas(6) StorageManagement-MIB::controllerState.1 = INTEGER: degraded(6) StorageManagement-MIB::controllerRebuildRateInPercent.1 = INTEGER: 30 StorageManagement-MIB::controllerFWVersion.1 = STRING: "5.0.2-0003" StorageManagement-MIB::controllerCacheSizeInMB.1 = INTEGER: 256 StorageManagement-MIB::controllerCacheSizeInBytes.1 = INTEGER: 0 StorageManagement-MIB::controllerPhysicalDeviceCount.1 = INTEGER: 5 StorageManagement-MIB::controllerLogicalDeviceCount.1 = INTEGER: 1 StorageManagement-MIB::controllerRollUpStatus.1 = INTEGER: nonCritical(4) StorageManagement-MIB::controllerComponentStatus.1 = INTEGER: nonCritical(4) StorageManagement-MIB::controllerNexusID.1 = STRING: "\\0" StorageManagement-MIB::controllerAlarmState.1 = INTEGER: disabled(2) StorageManagement-MIB::controllerDriverVersion.1 = STRING: "00.00.03.05 " StorageManagement-MIB::controllerPCISlot.1 = STRING: "embedded" StorageManagement-MIB::controllerClusterMode.1 = INTEGER: notApplicable(99) StorageManagement-MIB::controllerMinFWVersion.1 = STRING: "5.2.1-0067" StorageManagement-MIB::controllerMinDriverVersion.1 = STRING: "00.00.03.21" StorageManagement-MIB::controllerChannelCount.1 = INTEGER: 2 StorageManagement-MIB::controllerReconstructRate.1 = INTEGER: 30 StorageManagement-MIB::controllerPatrolReadRate.1 = INTEGER: 30 StorageManagement-MIB::controllerBGIRate.1 = INTEGER: 30 StorageManagement-MIB::controllerCheckConsistencyRate.1 = INTEGER: 30 StorageManagement-MIB::controllerPatrolReadMode.1 = INTEGER: automatic(1) StorageManagement-MIB::controllerPatrolReadState.1 = INTEGER: stopped(1) StorageManagement-MIB::controllerPatrolReadIterations.1 = INTEGER: 162 StorageManagement-MIB::controllerEntry.57.1 = INTEGER: 99 StorageManagement-MIB::controllerEntry.58.1 = INTEGER: 99 StorageManagement-MIB::channelNumber.1 = INTEGER: 1 StorageManagement-MIB::channelNumber.2 = INTEGER: 2 StorageManagement-MIB::channelName.1 = STRING: "Connector 0" StorageManagement-MIB::channelName.2 = STRING: "Connector 1" StorageManagement-MIB::channelState.1 = INTEGER: ready(1) StorageManagement-MIB::channelState.2 = INTEGER: ready(1) StorageManagement-MIB::channelRollUpStatus.1 = INTEGER: ok(3) StorageManagement-MIB::channelRollUpStatus.2 = INTEGER: ok(3) StorageManagement-MIB::channelComponentStatus.1 = INTEGER: ok(3) StorageManagement-MIB::channelComponentStatus.2 = INTEGER: ok(3) StorageManagement-MIB::channelNexusID.1 = STRING: "\\0\\0" StorageManagement-MIB::channelNexusID.2 = STRING: "\\0\\1" StorageManagement-MIB::channelBusType.1 = INTEGER: sas(8) StorageManagement-MIB::channelBusType.2 = INTEGER: sas(8) StorageManagement-MIB::enclosureNumber.1 = INTEGER: 1 StorageManagement-MIB::enclosureName.1 = STRING: "Backplane" StorageManagement-MIB::enclosureVendor.1 = STRING: "DELL" StorageManagement-MIB::enclosureState.1 = INTEGER: ready(1) StorageManagement-MIB::enclosureProductID.1 = STRING: "BACKPLANE " StorageManagement-MIB::enclosureType.1 = INTEGER: internal(1) StorageManagement-MIB::enclosureChannelNumber.1 = INTEGER: 0 StorageManagement-MIB::enclosureRollUpStatus.1 = INTEGER: ok(3) StorageManagement-MIB::enclosureComponentStatus.1 = INTEGER: ok(3) StorageManagement-MIB::enclosureNexusID.1 = STRING: "\\0\\0\\0" StorageManagement-MIB::enclosureFirmwareVersion.1 = STRING: "1.00" StorageManagement-MIB::enclosureSASAddress.1 = STRING: "50019090B4C67200" StorageManagement-MIB::arrayDiskNumber.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskNumber.2 = INTEGER: 2 StorageManagement-MIB::arrayDiskNumber.3 = INTEGER: 3 StorageManagement-MIB::arrayDiskNumber.4 = INTEGER: 4 StorageManagement-MIB::arrayDiskName.1 = STRING: "Physical Disk 0:0:0" StorageManagement-MIB::arrayDiskName.2 = STRING: "Physical Disk 0:0:1" StorageManagement-MIB::arrayDiskName.3 = STRING: "Physical Disk 0:0:2" StorageManagement-MIB::arrayDiskName.4 = STRING: "Physical Disk 0:0:3" StorageManagement-MIB::arrayDiskVendor.1 = STRING: "DELL " StorageManagement-MIB::arrayDiskVendor.2 = STRING: "DELL " StorageManagement-MIB::arrayDiskVendor.3 = STRING: "DELL " StorageManagement-MIB::arrayDiskVendor.4 = STRING: "DELL " StorageManagement-MIB::arrayDiskState.1 = INTEGER: online(3) StorageManagement-MIB::arrayDiskState.2 = INTEGER: online(3) StorageManagement-MIB::arrayDiskState.3 = INTEGER: online(3) StorageManagement-MIB::arrayDiskState.4 = INTEGER: online(3) StorageManagement-MIB::arrayDiskProductID.1 = STRING: "ST3146755SS " StorageManagement-MIB::arrayDiskProductID.2 = STRING: "ST3146755SS " StorageManagement-MIB::arrayDiskProductID.3 = STRING: "ST3146755SS " StorageManagement-MIB::arrayDiskProductID.4 = STRING: "ST3146755SS " StorageManagement-MIB::arrayDiskSerialNo.1 = STRING: "3LN0LRL0 " StorageManagement-MIB::arrayDiskSerialNo.2 = STRING: "3LN0JYJS " StorageManagement-MIB::arrayDiskSerialNo.3 = STRING: "3LN0LR0V " StorageManagement-MIB::arrayDiskSerialNo.4 = STRING: "3LN0JH97 " StorageManagement-MIB::arrayDiskRevision.1 = STRING: "T106" StorageManagement-MIB::arrayDiskRevision.2 = STRING: "T106" StorageManagement-MIB::arrayDiskRevision.3 = STRING: "T106" StorageManagement-MIB::arrayDiskRevision.4 = STRING: "T106" StorageManagement-MIB::arrayDiskEnclosureID.1 = STRING: "0" StorageManagement-MIB::arrayDiskEnclosureID.2 = STRING: "0" StorageManagement-MIB::arrayDiskEnclosureID.3 = STRING: "0" StorageManagement-MIB::arrayDiskEnclosureID.4 = STRING: "0" StorageManagement-MIB::arrayDiskChannel.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskChannel.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskChannel.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskChannel.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskLengthInMB.1 = INTEGER: 139392 StorageManagement-MIB::arrayDiskLengthInMB.2 = INTEGER: 139392 StorageManagement-MIB::arrayDiskLengthInMB.3 = INTEGER: 139392 StorageManagement-MIB::arrayDiskLengthInMB.4 = INTEGER: 139392 StorageManagement-MIB::arrayDiskLengthInBytes.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskLengthInBytes.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskLengthInBytes.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskLengthInBytes.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskLargestContiguousFreeSpaceInMB.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskLargestContiguousFreeSpaceInMB.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskLargestContiguousFreeSpaceInMB.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskLargestContiguousFreeSpaceInMB.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskLargestContiguousFreeSpaceInBytes.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskLargestContiguousFreeSpaceInBytes.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskLargestContiguousFreeSpaceInBytes.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskLargestContiguousFreeSpaceInBytes.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskTargetID.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskTargetID.2 = INTEGER: 1 StorageManagement-MIB::arrayDiskTargetID.3 = INTEGER: 2 StorageManagement-MIB::arrayDiskTargetID.4 = INTEGER: 3 StorageManagement-MIB::arrayDiskLunID.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskLunID.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskLunID.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskLunID.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskUsedSpaceInMB.1 = INTEGER: 139392 StorageManagement-MIB::arrayDiskUsedSpaceInMB.2 = INTEGER: 139392 StorageManagement-MIB::arrayDiskUsedSpaceInMB.3 = INTEGER: 139392 StorageManagement-MIB::arrayDiskUsedSpaceInMB.4 = INTEGER: 139392 StorageManagement-MIB::arrayDiskUsedSpaceInBytes.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskUsedSpaceInBytes.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskUsedSpaceInBytes.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskUsedSpaceInBytes.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskFreeSpaceInMB.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskFreeSpaceInMB.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskFreeSpaceInMB.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskFreeSpaceInMB.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskFreeSpaceInBytes.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskFreeSpaceInBytes.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskFreeSpaceInBytes.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskFreeSpaceInBytes.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskBusType.1 = INTEGER: sas(8) StorageManagement-MIB::arrayDiskBusType.2 = INTEGER: sas(8) StorageManagement-MIB::arrayDiskBusType.3 = INTEGER: sas(8) StorageManagement-MIB::arrayDiskBusType.4 = INTEGER: sas(8) StorageManagement-MIB::arrayDiskSpareState.1 = INTEGER: notASpare(5) StorageManagement-MIB::arrayDiskSpareState.2 = INTEGER: notASpare(5) StorageManagement-MIB::arrayDiskSpareState.3 = INTEGER: notASpare(5) StorageManagement-MIB::arrayDiskSpareState.4 = INTEGER: notASpare(5) StorageManagement-MIB::arrayDiskRollUpStatus.1 = INTEGER: ok(3) StorageManagement-MIB::arrayDiskRollUpStatus.2 = INTEGER: ok(3) StorageManagement-MIB::arrayDiskRollUpStatus.3 = INTEGER: ok(3) StorageManagement-MIB::arrayDiskRollUpStatus.4 = INTEGER: ok(3) StorageManagement-MIB::arrayDiskComponentStatus.1 = INTEGER: ok(3) StorageManagement-MIB::arrayDiskComponentStatus.2 = INTEGER: ok(3) StorageManagement-MIB::arrayDiskComponentStatus.3 = INTEGER: ok(3) StorageManagement-MIB::arrayDiskComponentStatus.4 = INTEGER: ok(3) StorageManagement-MIB::arrayDiskNexusID.1 = STRING: "\\0\\0\\0\\0" StorageManagement-MIB::arrayDiskNexusID.2 = STRING: "\\0\\0\\0\\1" StorageManagement-MIB::arrayDiskNexusID.3 = STRING: "\\0\\0\\0\\2" StorageManagement-MIB::arrayDiskNexusID.4 = STRING: "\\0\\0\\0\\3" StorageManagement-MIB::arrayDiskPartNumber.1 = STRING: "SG0DR2381253172FLRL0A00 " StorageManagement-MIB::arrayDiskPartNumber.2 = STRING: "SG0DR2381253172FJYJSA00 " StorageManagement-MIB::arrayDiskPartNumber.3 = STRING: "SG0DR2381253172FLR0VA00 " StorageManagement-MIB::arrayDiskPartNumber.4 = STRING: "SG0DR2381253172FJH97A00 " StorageManagement-MIB::arrayDiskSASAddress.1 = STRING: "5000C50002380201" StorageManagement-MIB::arrayDiskSASAddress.2 = STRING: "5000C50002385B89" StorageManagement-MIB::arrayDiskSASAddress.3 = STRING: "5000C50002385AA9" StorageManagement-MIB::arrayDiskSASAddress.4 = STRING: "5000C500023841E1" StorageManagement-MIB::arrayDiskSmartAlertIndication.1 = INTEGER: no(1) StorageManagement-MIB::arrayDiskSmartAlertIndication.2 = INTEGER: no(1) StorageManagement-MIB::arrayDiskSmartAlertIndication.3 = INTEGER: no(1) StorageManagement-MIB::arrayDiskSmartAlertIndication.4 = INTEGER: no(1) StorageManagement-MIB::arrayDiskManufactureDay.1 = STRING: "07" StorageManagement-MIB::arrayDiskManufactureDay.2 = STRING: "07" StorageManagement-MIB::arrayDiskManufactureDay.3 = STRING: "07" StorageManagement-MIB::arrayDiskManufactureDay.4 = STRING: "07" StorageManagement-MIB::arrayDiskManufactureWeek.1 = STRING: "07" StorageManagement-MIB::arrayDiskManufactureWeek.2 = STRING: "07" StorageManagement-MIB::arrayDiskManufactureWeek.3 = STRING: "07" StorageManagement-MIB::arrayDiskManufactureWeek.4 = STRING: "07" StorageManagement-MIB::arrayDiskManufactureYear.1 = STRING: "2005" StorageManagement-MIB::arrayDiskManufactureYear.2 = STRING: "2005" StorageManagement-MIB::arrayDiskManufactureYear.3 = STRING: "2005" StorageManagement-MIB::arrayDiskManufactureYear.4 = STRING: "2005" StorageManagement-MIB::arrayDiskMediaType.1 = INTEGER: hdd(2) StorageManagement-MIB::arrayDiskMediaType.2 = INTEGER: hdd(2) StorageManagement-MIB::arrayDiskMediaType.3 = INTEGER: hdd(2) StorageManagement-MIB::arrayDiskMediaType.4 = INTEGER: hdd(2) StorageManagement-MIB::arrayDiskEntry.36.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskEntry.36.2 = INTEGER: 1 StorageManagement-MIB::arrayDiskEntry.36.3 = INTEGER: 1 StorageManagement-MIB::arrayDiskEntry.36.4 = INTEGER: 1 StorageManagement-MIB::arrayDiskEntry.40.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskEntry.40.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskEntry.40.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskEntry.40.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskEntry.41.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskEntry.41.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskEntry.41.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskEntry.41.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskEnclosureConnectionNumber.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionNumber.2 = INTEGER: 2 StorageManagement-MIB::arrayDiskEnclosureConnectionNumber.3 = INTEGER: 3 StorageManagement-MIB::arrayDiskEnclosureConnectionNumber.4 = INTEGER: 4 StorageManagement-MIB::arrayDiskEnclosureConnectionArrayDiskName.1 = STRING: "Physical Disk 0:0:0" StorageManagement-MIB::arrayDiskEnclosureConnectionArrayDiskName.2 = STRING: "Physical Disk 0:0:1" StorageManagement-MIB::arrayDiskEnclosureConnectionArrayDiskName.3 = STRING: "Physical Disk 0:0:2" StorageManagement-MIB::arrayDiskEnclosureConnectionArrayDiskName.4 = STRING: "Physical Disk 0:0:3" StorageManagement-MIB::arrayDiskEnclosureConnectionArrayDiskNumber.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionArrayDiskNumber.2 = INTEGER: 2 StorageManagement-MIB::arrayDiskEnclosureConnectionArrayDiskNumber.3 = INTEGER: 3 StorageManagement-MIB::arrayDiskEnclosureConnectionArrayDiskNumber.4 = INTEGER: 4 StorageManagement-MIB::arrayDiskEnclosureConnectionEnclosureName.1 = STRING: "Backplane" StorageManagement-MIB::arrayDiskEnclosureConnectionEnclosureName.2 = STRING: "Backplane" StorageManagement-MIB::arrayDiskEnclosureConnectionEnclosureName.3 = STRING: "Backplane" StorageManagement-MIB::arrayDiskEnclosureConnectionEnclosureName.4 = STRING: "Backplane" StorageManagement-MIB::arrayDiskEnclosureConnectionEnclosureNumber.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionEnclosureNumber.2 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionEnclosureNumber.3 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionEnclosureNumber.4 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionControllerName.1 = STRING: "PERC 5/i Integrated" StorageManagement-MIB::arrayDiskEnclosureConnectionControllerName.2 = STRING: "PERC 5/i Integrated" StorageManagement-MIB::arrayDiskEnclosureConnectionControllerName.3 = STRING: "PERC 5/i Integrated" StorageManagement-MIB::arrayDiskEnclosureConnectionControllerName.4 = STRING: "PERC 5/i Integrated" StorageManagement-MIB::arrayDiskEnclosureConnectionControllerNumber.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionControllerNumber.2 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionControllerNumber.3 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionControllerNumber.4 = INTEGER: 1 StorageManagement-MIB::batteryNumber.1 = INTEGER: 1 StorageManagement-MIB::batteryName.1 = STRING: "Battery 0" StorageManagement-MIB::batteryVendor.1 = STRING: "DELL" StorageManagement-MIB::batteryState.1 = INTEGER: ready(1) StorageManagement-MIB::batteryRollUpStatus.1 = INTEGER: ok(3) StorageManagement-MIB::batteryComponentStatus.1 = INTEGER: ok(3) StorageManagement-MIB::batteryNexusID.1 = STRING: "\\0\\0" StorageManagement-MIB::batteryPredictedCapacity.1 = INTEGER: ready(2) StorageManagement-MIB::batteryNextLearnTime.1 = INTEGER: 21 StorageManagement-MIB::batteryLearnState.1 = INTEGER: idle(16) StorageManagement-MIB::batteryEntry.13.1 = INTEGER: 0 StorageManagement-MIB::batteryMaxLearnDelay.1 = INTEGER: 168 StorageManagement-MIB::batteryConnectionNumber.1 = INTEGER: 1 StorageManagement-MIB::batteryConnectionBatteryName.1 = STRING: "Battery 0" StorageManagement-MIB::batteryConnectionBatteryNumber.1 = INTEGER: 1 StorageManagement-MIB::batteryConnectionControllerName.1 = STRING: "PERC 5/i Integrated" StorageManagement-MIB::batteryConnectionControllerNumber.1 = INTEGER: 1 StorageManagement-MIB::virtualDiskNumber.1 = INTEGER: 1 StorageManagement-MIB::virtualDiskName.1 = STRING: "Virtual Disk 0" StorageManagement-MIB::virtualDiskDeviceName.1 = STRING: "/dev/sda" StorageManagement-MIB::virtualDiskState.1 = INTEGER: ready(1) StorageManagement-MIB::virtualDiskLengthInMB.1 = INTEGER: 278784 StorageManagement-MIB::virtualDiskLengthInBytes.1 = INTEGER: 0 StorageManagement-MIB::virtualDiskWritePolicy.1 = INTEGER: writeBack(3) StorageManagement-MIB::virtualDiskReadPolicy.1 = INTEGER: noReadAhead(5) StorageManagement-MIB::virtualDiskCachePolicy.1 = INTEGER: not-applicable(99) StorageManagement-MIB::virtualDiskLayout.1 = INTEGER: raid-10(10) StorageManagement-MIB::virtualDiskCurStripeSizeInMB.1 = INTEGER: 0 StorageManagement-MIB::virtualDiskCurStripeSizeInBytes.1 = INTEGER: 65536 StorageManagement-MIB::virtualDiskTargetID.1 = INTEGER: 0 StorageManagement-MIB::virtualDiskRollUpStatus.1 = INTEGER: ok(3) StorageManagement-MIB::virtualDiskComponentStatus.1 = INTEGER: ok(3) StorageManagement-MIB::virtualDiskNexusID.1 = STRING: "\\0\\0" StorageManagement-MIB::virtualDiskArrayDiskType.1 = INTEGER: sas(1) StorageManagement-MIB::virtualDiskEntry.23.1 = INTEGER: 2 StorageManagement-MIB::virtualDiskEntry.24.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskLogicalConnectionNumber.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskLogicalConnectionNumber.2 = INTEGER: 2 StorageManagement-MIB::arrayDiskLogicalConnectionNumber.3 = INTEGER: 3 StorageManagement-MIB::arrayDiskLogicalConnectionNumber.4 = INTEGER: 4 StorageManagement-MIB::arrayDiskLogicalConnectionArrayDiskName.1 = STRING: "Physical Disk 0:0:0" StorageManagement-MIB::arrayDiskLogicalConnectionArrayDiskName.2 = STRING: "Physical Disk 0:0:1" StorageManagement-MIB::arrayDiskLogicalConnectionArrayDiskName.3 = STRING: "Physical Disk 0:0:2" StorageManagement-MIB::arrayDiskLogicalConnectionArrayDiskName.4 = STRING: "Physical Disk 0:0:3" StorageManagement-MIB::arrayDiskLogicalConnectionArrayDiskNumber.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskLogicalConnectionArrayDiskNumber.2 = INTEGER: 2 StorageManagement-MIB::arrayDiskLogicalConnectionArrayDiskNumber.3 = INTEGER: 3 StorageManagement-MIB::arrayDiskLogicalConnectionArrayDiskNumber.4 = INTEGER: 4 StorageManagement-MIB::arrayDiskLogicalConnectionVirtualDiskName.1 = STRING: "Virtual Disk 0" StorageManagement-MIB::arrayDiskLogicalConnectionVirtualDiskName.2 = STRING: "Virtual Disk 0" StorageManagement-MIB::arrayDiskLogicalConnectionVirtualDiskName.3 = STRING: "Virtual Disk 0" StorageManagement-MIB::arrayDiskLogicalConnectionVirtualDiskName.4 = STRING: "Virtual Disk 0" StorageManagement-MIB::arrayDiskLogicalConnectionVirtualDiskNumber.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskLogicalConnectionVirtualDiskNumber.2 = INTEGER: 1 StorageManagement-MIB::arrayDiskLogicalConnectionVirtualDiskNumber.3 = INTEGER: 1 StorageManagement-MIB::arrayDiskLogicalConnectionVirtualDiskNumber.4 = INTEGER: 1

    Read the article

  • Why do some user agents have spam urls in them (and why are they always Opera/Presto User-Agents)?

    - by Erx_VB.NExT.Coder
    If you go to (say) the last 100 entries (visits) to the botsvsbrowsers.com website (exact link, feel free to take a look: http://www.botsvsbrowsers.com/recent/listings/index.html ), you'd notice that almost every User Agent that has the keywords "Opera" and "Presto" inside them, will almost certainly have a web link (URL/Web Address) inside it, and it won't just be a normal web address, but a HTML anchor tag/link to that address. Why is this so, I could not even find a single discussion about it on the internet, nowhere, I tried varying my search terms many times. If the user agent contains the words "Opera" and "Presto" it doesnt mean it will have this weblink, but it means there is about an 80% change that it will. A typical anchor tag/link inside a user agent will look like this: Mozilla/4.0 <a href="http://osis-uk.co.uk/disabled-equipment">disability equipment</a> (Windows NT 5.1; U; en) Presto/2.10.229 Version/11.60 If you check it out at the website, http://www.botsvsbrowsers.com/recent/listings/index.html you will notice that the back and forward arrows are in there unescaped format. This isn't just true for botsvsbrowsers, but several other user agent listing sites. I'm really confused and feel line I'm in a room full of 10,000 people and am the only one seeing this ghost :). If I'm doing statistical analysis, should I include or exclude this type of user agent from my listing (ie: are these just normal users who've set their user agents to attempt to drive some traffic to their sites as they browser the web), or is there something else going on? The fact that it is so consistent in terms of its format leads me to believe that it is an automated process (the setting or alteration of the user agent) so I cannot decide or understand the process by which this change is made (I know how to change a user agent), but unsure which program or facility is doing this, especially since it is exclusive to Opera (Presto) user agents that are beyond I think an 8 or 9 point something browser version. I've run some statistical tests, parsing entries from all over the place, writing custom programs, to get a better understanding of this. Keep in mind that I see normal URL's in user agents infrequently, they are just text such as +http://www.someSite.com appended to a user agent normally, especially if its a crawler or bot it provided its service URL, this is normal and isnt done with an embedded link (A HREF=) etc, so I'm not talking about "those".

    Read the article

  • Debian amd64 on Dell Studio 540 reboot hangs

    - by Shcheklein
    Hi, I have Dell Studio 540 desktop and Debian Lenny installed on it: 2.6.26-2-amd64 #1 SMP Tue Mar 9 22:29:32 UTC 2010 x86_64 GNU/Linux The problem is that I can't reboot it. It just hangs after "Will now restart" message. I've already tried: reboot=b, reboot=a, reboot=h kernel options. Nothing helps. Additional info (I can provide any other information): dmidecode System Information Manufacturer: Dell Inc. Product Name: Studio 540 lspci 00:00.0 Host bridge: Intel Corporation 4 Series Chipset DRAM Controller (rev 03) 00:02.0 VGA compatible controller: Intel Corporation 4 Series Chipset Integrated Graphics Controller (rev 03) 00:02.1 Display controller: Intel Corporation 4 Series Chipset Integrated Graphics Controller (rev 03) 00:1a.0 USB Controller: Intel Corporation 82801JI (ICH10 Family) USB UHCI Controller #4 00:1a.1 USB Controller: Intel Corporation 82801JI (ICH10 Family) USB UHCI Controller #5 00:1a.2 USB Controller: Intel Corporation 82801JI (ICH10 Family) USB UHCI Controller #6 00:1a.7 USB Controller: Intel Corporation 82801JI (ICH10 Family) USB2 EHCI Controller #2 00:1b.0 Audio device: Intel Corporation 82801JI (ICH10 Family) HD Audio Controller 00:1c.0 PCI bridge: Intel Corporation 82801JI (ICH10 Family) PCI Express Port 1 00:1c.2 PCI bridge: Intel Corporation 82801JI (ICH10 Family) PCI Express Port 3 00:1c.5 PCI bridge: Intel Corporation 82801JI (ICH10 Family) PCI Express Port 6 00:1d.0 USB Controller: Intel Corporation 82801JI (ICH10 Family) USB UHCI Controller #1 00:1d.1 USB Controller: Intel Corporation 82801JI (ICH10 Family) USB UHCI Controller #2 00:1d.2 USB Controller: Intel Corporation 82801JI (ICH10 Family) USB UHCI Controller #3 00:1d.7 USB Controller: Intel Corporation 82801JI (ICH10 Family) USB2 EHCI Controller #1 00:1e.0 PCI bridge: Intel Corporation 82801 PCI Bridge (rev 90) 00:1f.0 ISA bridge: Intel Corporation 82801JIR (ICH10R) LPC Interface Controller 00:1f.2 IDE interface: Intel Corporation 82801JI (ICH10 Family) 4 port SATA IDE Controller 00:1f.3 SMBus: Intel Corporation 82801JI (ICH10 Family) SMBus Controller 00:1f.5 IDE interface: Intel Corporation 82801JI (ICH10 Family) 2 port SATA IDE Controller 02:00.0 FireWire (IEEE 1394): JMicron Technologies, Inc. Device 2380 03:00.0 Ethernet controller: Realtek Semiconductor Co., Ltd. RTL8111/8168B PCI Express Gigabit Ethernet controller (rev 02)

    Read the article

  • Dell XPS m1530 system cannot boot need 130w or greater

    - by KPS
    I have a Dell XPS M1530 and I lost my old AC adapter but ordered a new one. For the longest time it always had a battery charge so I was able to boot into the OS but now it is completely dead. I have a generic charger that slowly charged the laptop when it was in the OS but does not when the computer is off. When I boot up I get the following error: The AC power adapter type cannot be determined. The system can only boot with a 130 W power adapter or greater. Strike F1 key to shutdown. I cannot even enter the BIOs setup screen or boot menu, is there a way around this? I heard from the local tech that Dell has a special feature to boot from thumb drive before getting past the initial logo. I am doing my best to avoid purchasing a new charger since it worked just fine when the OS was running, I am hoping to get this thing going. Is there a way to charge the battery externally? Thanks in advance for any help!

    Read the article

  • Dell Latitude D510 Runs From Battery But Not AC Adapter

    - by Jason George
    I have a Dell Latitude D510 that went belly up around two years ago. It will run from the battery, however, the wall adapter will neither power the machine nor charge the battery. Once the battery is dead, the machine is dead. Since it died I've searched repeatedly for solutions. I've tried a new AC adapter and even removed and replaced the DC jack thinking one of the solder joints might be bad. Both to no avail. After two years of searching I finally found the answer today. Since it's such a simple fix and I had such a hard time finding it I wanted to post the info for others (as it is apparently a common issue with the D510). -----SOLUTION----- It seems this is commonly caused by a cracked solder joint at pin 1 on an inductor filter pair (FL2) near the power jack. Pins 1 and 4 are ground and pins 2 and 3 are power. There should be 20V from 1 to 2 and 3. Anything less indicates a cracked joint that is increasing resistance and dropping the supply voltage. Repair simply requires reflowing all four pins with a little added solder for security. Detailed instructions can be found here. Dell Latitude D510 solder problem

    Read the article