  • Can't manage iPod from linux anymore

    - by kemp
    I used to be able to see and manage my iPod with different softwares: Amarok, Rhythmbox, GTKPod. The device is a nano 1st generation 4gb. Currently it mounts regularly and can be accessed from the file system, but I get this in dmesg: [ 1547.617891] scsi 11:0:0:0: Direct-Access Apple iPod 1.62 PQ: 0 ANSI: 0 [ 1547.619103] sd 11:0:0:0: Attached scsi generic sg2 type 0 [ 1547.620478] sd 11:0:0:0: [sdb] Adjusting the sector count from its reported value: 7999488 [ 1547.620494] sd 11:0:0:0: [sdb] 7999487 512-byte hardware sectors: (4.09 GB/3.81 GiB) [ 1547.621718] sd 11:0:0:0: [sdb] Write Protect is off [ 1547.621726] sd 11:0:0:0: [sdb] Mode Sense: 68 00 00 08 [ 1547.621732] sd 11:0:0:0: [sdb] Assuming drive cache: write through [ 1547.623591] sd 11:0:0:0: [sdb] Adjusting the sector count from its reported value: 7999488 [ 1547.624993] sd 11:0:0:0: [sdb] Assuming drive cache: write through [ 1547.625003] sdb: sdb1 sdb2 [ 1547.629686] sd 11:0:0:0: [sdb] Attached SCSI removable disk [ 1548.084026] FAT: utf8 is not a recommended IO charset for FAT filesystems, filesystem will be case sensitive! [ 1548.369502] FAT: utf8 is not a recommended IO charset for FAT filesystems, filesystem will be case sensitive! [ 1548.504358] FAT: invalid media value (0x2f) [ 1548.504363] VFS: Can't find a valid FAT filesystem on dev sdb1. [ 1548.945173] FAT: utf8 is not a recommended IO charset for FAT filesystems, filesystem will be case sensitive! [ 1548.945179] FAT: invalid media value (0x2f) [ 1548.945182] VFS: Can't find a valid FAT filesystem on dev sdb1. [ 1610.092886] usb 2-6: USB disconnect, address 9 The only application that can access it (partially) is Rhythmbox. I say partially because I can transfer files to the iPod but can't remove or modify them. Also one transfer didn't finish and only 9 out of 16 songs were delivered to the device. All other softwares I tried (GTKPod, Amarok, Songbird) don't even detect it. What can I do to troubleshoot this? EDIT: # fdisk -l /dev/sdb Disk /dev/sdb: 4095 MB, 4095737344 bytes 241 heads, 62 sectors/track, 535 cylinders Units = cylinders of 14942 * 512 = 7650304 bytes Disk identifier: 0x20202020 Device Boot Start End Blocks Id System /dev/sdb1 1 11 80293+ 0 Empty Partition 1 has different physical/logical beginnings (non-Linux?): phys=(0, 1, 1) logical=(0, 1, 2) Partition 1 has different physical/logical endings: phys=(9, 254, 63) logical=(10, 181, 8) Partition 1 does not end on cylinder boundary. /dev/sdb2 11 536 3919415+ b W95 FAT32 Partition 2 has different physical/logical beginnings (non-Linux?): phys=(10, 0, 7) logical=(10, 181, 15) Partition 2 has different physical/logical endings: phys=(497, 240, 62) logical=(535, 88, 61) EDIT2: The "before" state is hard to tell, it was a lot of updates ago. Haven't been using my iPod for a while so I can't say when exactly it stopped working. I'm sure Amarok was still at version 1.X but can't remember when it was. My current system is debian testing fully updated. NOTE: just noticed that if I mount the device manually instead of letting nautilus automount it, I can see it again on GTKPod but still not on Banshee AND it's vanished from Rhythmbox...

    Read the article

  • How to remove iso 9660 from USB?

    - by a_m0d
    I have somehow managed to write an iso 9660 image onto my USB drive, which makes all my computer think that the device is actually a CD. I have tried various methods of removing this partition, but nothing seems to work. I have tried fdisk, which says $ fdisk -l /dev/sdb Cannot open /dev/sdb parted crashes when I try to use it on this device. I have even tried $ dd if=/dev/zero of=/dev/sdb but it just hangs with no output (either on screen or on disk). However, when I plug the USB in, it does mount, and I can view (but not edit) the files on it. edit: now the result is $ dd if=/dev/zero of=/dev/sdb dd: opening `/dev/sdb': Read-only file system I have also tried re-formatting it on Windows, but it gets to the end of the format process and then says "Couldn't format the drive". How can I remove this partition and get my whole USB drive back to normal again? EDIT 1: Trying a simple mkfs doesn't work: $ sudo mkfs -t vfat /dev/sdb mkfs.vfat 3.0.0 (28 Sep 2008) mkfs.vfat: Will not try to make filesystem on full-disk device '/dev/sdb' (use -I if wanted) I can't do mkfs on /dev/sdb1 because there is no such partition, as shown:$ ls /dev | grep sdb sdb EDIT 2: This is the information posted by dmesg when I plug the device in:$ dmesg . . (snip) . usb 2-1: New USB device found, idVendor=058f, idProduct=6387 usb 2-1: New USB device strings: Mfr=1, Product=2, SerialNumber=3 usb 2-1: Product: Mass Storage usb 2-1: Manufacturer: Generic usb 2-1: SerialNumber: G0905000000000010885 usb-storage: device found at 4 usb-storage: waiting for device to settle before scanning usb-storage: device scan complete scsi 6:0:0:0: Direct-Access FLASH Drive AU_USB20 8.07 PQ: 0 ANSI: 2 sd 6:0:0:0: [sdb] 4069376 512-byte hardware sectors (2084 MB) sd 6:0:0:0: [sdb] Write Protect is off sd 6:0:0:0: [sdb] Mode Sense: 03 00 00 00 sd 6:0:0:0: [sdb] Assuming drive cache: write through sd 6:0:0:0: [sdb] 4069376 512-byte hardware sectors (2084 MB) sd 6:0:0:0: [sdb] Write Protect is off sd 6:0:0:0: [sdb] Mode Sense: 03 00 00 00 sd 6:0:0:0: [sdb] Assuming drive cache: write through sdb: unknown partition table sd 6:0:0:0: [sdb] Attached SCSI removable disk sd 6:0:0:0: Attached scsi generic sg2 type 0 ISO 9660 Extensions: Microsoft Joliet Level 3 ISO 9660 Extensions: RRIP_1991A SELinux: initialized (dev sdb, type iso9660), uses genfs_contexts CE: hpet increasing min_delta_ns to 15000 nsec This shows that the device is formatted as ISO 9660 and that it is /dev/sdb. EDIT 3: This is the message that I find at the bottom of dmesg after running cfdisk and writing a new partition table to the disk:SELinux: initialized (dev sdb, type iso9660), uses genfs_contexts sd 17:0:0:0: [sdb] Device not ready: Sense Key : Not Ready [current] sd 17:0:0:0: [sdb] Device not ready: < ASC=0xff ASCQ=0xffASC=0xff < ASCQ=0xff end_request: I/O error, dev sdb, sector 0 Buffer I/O error on device sdb, logical block 0 lost page write due to I/O error on sdb

    Read the article

  • mount another drive to the same directory

    - by Ken Autotron
    I recently purchased a server that was advertised as 2TB (2 1TB drives) in size, when I use it it reports only one of the drives, I would like to be able to use both as if one drive. here is the specs... sudo lshw -C disk *-disk description: ATA Disk product: TOSHIBA DT01ACA1 vendor: Toshiba physical id: 0.0.0 bus info: scsi@1:0.0.0 logical name: /dev/sda version: MS2O serial: 13EJ81XPS size: 931GiB (1TB) capabilities: partitioned partitioned:dos configuration: ansiversion=5 signature=0005b3dd *-disk description: ATA Disk product: TOSHIBA DT01ACA1 vendor: Toshiba physical id: 0.0.0 bus info: scsi@4:0.0.0 logical name: /dev/sdb version: MS2O serial: 13OX3TKPS size: 931GiB (1TB) capabilities: partitioned partitioned:dos configuration: ansiversion=5 signature=00030e86 and fdisk -l Disk /dev/sdb: 1000.2 GB, 1000204886016 bytes 255 heads, 63 sectors/track, 121601 cylinders, total 1953525168 sectors Units = sectors of 1 * 512 = 512 bytes Sector size (logical/physical): 512 bytes / 4096 bytes I/O size (minimum/optimal): 4096 bytes / 4096 bytes Disk identifier: 0x00030e86 Device Boot Start End Blocks Id System /dev/sdb1 * 4096 41947135 20971520 fd Linux raid autodetect /dev/sdb2 41947136 1952468991 955260928 fd Linux raid autodetect /dev/sdb3 1952468992 1953519615 525312 82 Linux swap / Solaris Disk /dev/sda: 1000.2 GB, 1000204886016 bytes 255 heads, 63 sectors/track, 121601 cylinders, total 1953525168 sectors Units = sectors of 1 * 512 = 512 bytes Sector size (logical/physical): 512 bytes / 4096 bytes I/O size (minimum/optimal): 4096 bytes / 4096 bytes Disk identifier: 0x0005b3dd Device Boot Start End Blocks Id System /dev/sda1 * 4096 41947135 20971520 fd Linux raid autodetect /dev/sda2 41947136 1952468991 955260928 fd Linux raid autodetect /dev/sda3 1952468992 1953519615 525312 82 Linux swap / Solaris Disk /dev/md2: 978.2 GB, 978187124736 bytes 2 heads, 4 sectors/track, 238815216 cylinders, total 1910521728 sectors Units = sectors of 1 * 512 = 512 bytes Sector size (logical/physical): 512 bytes / 4096 bytes I/O size (minimum/optimal): 4096 bytes / 4096 bytes Disk identifier: 0x00000000 Disk /dev/md2 doesn't contain a valid partition table Disk /dev/md1: 21.5 GB, 21474770944 bytes 2 heads, 4 sectors/track, 5242864 cylinders, total 41942912 sectors Units = sectors of 1 * 512 = 512 bytes Sector size (logical/physical): 512 bytes / 4096 bytes I/O size (minimum/optimal): 4096 bytes / 4096 bytes Disk identifier: 0x00000000 Disk /dev/md1 doesn't contain a valid partition table is it possible to mount both drives to say /Home/ so I would have 2TB of usable space?

    Read the article

  • Which Ubuntu version to use on a MAXDATA laptop Eco 3100X ? with this system info

    - by Erjet Malaj
    i am speaking as new ubuntu user, i just have installed ubuntu 10.04 on my laptop, but is running very slow... So i am here to ask you a question: WHich ubuntu version can fit for my laptop MAXDATA Eco 3100x, . My Laptop System Information are: SYSTEM INFORMATION Running Ubuntu Linux, the Ubuntu 10.04 (lucid) release. GNOME: 2.30.2 (Ubuntu 2010-06-25) Kernel version: 2.6.32-40-generic (#87-Ubuntu SMP Mon Mar 5 20:26:31 UTC 2012) GCC: 4.4.3 (i486-linux-gnu) Xorg: unknown (25 February 2012 06:59:39AM) (25 February 2012 06:59:39AM) Hostname: lotus-laptop Uptime: 0 days 1 h 6 min CPU INFORMATION GenuineIntel, Intel(R) Pentium(R) 4 CPU 2.40GHz Number of CPUs: 1 CPU clock currently at 2390.561 MHz with 512 KB cache Numbering: family(15) model(2) stepping(7) Bogomips: 4781.12 Flags: fpu vme de pse tsc msr pae mce cx8 mtrr pge mca cmov pat pse36 clflush dts acpi mmx fxsr sse sse2 ss ht tm pbe up pebs bts cid MEMORY INFORMATION Total memory: 228 MB Total swap: 455 MB STORAGE INFORMATION SCSI device - scsi0 Vendor: ATA Model: IBM-DJSA-210 SCSI device - scsi1 Vendor: TOSHIBA Model: DVD-ROM SD-C2502 HARDWARE INFORMATION MOTHERBOARD Host bridge Silicon Integrated Systems [SiS] 650/M650 Host (rev 11) PCI bridge(s) Silicon Integrated Systems [SiS] Virtual PCI-to-PCI bridge (AGP) Silicon Integrated Systems [SiS] Virtual PCI-to-PCI bridge (AGP) USB controller(s) Silicon Integrated Systems [SiS] USB 1.1 Controller (rev 0f) (prog-if 10) Silicon Integrated Systems [SiS] USB 1.1 Controller (rev 0f) (prog-if 10) Silicon Integrated Systems [SiS] USB 1.1 Controller (rev 0f) (prog-if 10) Silicon Integrated Systems [SiS] USB 2.0 Controller (prog-if 20) Silicon Integrated Systems [SiS] USB 1.1 Controller (rev 0f) (prog-if 10) Silicon Integrated Systems [SiS] USB 1.1 Controller (rev 0f) (prog-if 10) Silicon Integrated Systems [SiS] USB 1.1 Controller (rev 0f) (prog-if 10) Silicon Integrated Systems [SiS] USB 2.0 Controller (prog-if 20) ISA bridge Silicon Integrated Systems [SiS] SiS962 [MuTIOL Media IO] (rev 04) IDE interface Silicon Integrated Systems [SiS] 5513 [IDE] (prog-if 80 [Master]) Subsystem: Silicon Integrated Systems [SiS] 5513 [IDE] GRAPHIC CARD VGA controller Silicon Integrated Systems [SiS] 65x/M650/740 PCI/AGP VGA Display Adapter Subsystem: Uniwill Computer Corp Device 5103 SOUND CARD Multimedia controller Silicon Integrated Systems [SiS] AC'97 Sound Controller (rev a0) Subsystem: Uniwill Computer Corp Device 5203 NETWORK Ethernet controller Silicon Integrated Systems [SiS] SiS900 PCI Fast Ethernet (rev 91) Subsystem: Uniwill Computer Corp Device 5002 Modem Silicon Integrated Systems [SiS] AC'97 Modem Controller (rev a0) Subsystem: Uniwill Computer Corp Device 4003 Thanks you asap. :-) E

    Read the article

  • Getting FC11 to run under VMware Server, converted from physical machine

    - by Kristian
    I have a FC11 installation that I have converted to a VMware disk image to run om my VMware Server. I converted it with qemu-img, as the VMware Converter software apparently only converts Linux hosts to VMware Infrastructure servers. The disk image boots fine (grub is loaded and boots the kernel) but it seems like the disk is not found by the kernel, and the boot process stalls. Hotplugging USB devices work (the kernel prints debug information) and I'm able to press keys (Ctrl-Alt-Delete for instance). The VMware guest OS is set to RedHat Enterprise Linux 5 (32 bit), and I have tried both the LSI Logic, LSI Logic SAS and VMware Accelerated SCSI SCSI controllers, to no avail. I'm able to boot an installer disk and get into rescue mode and mount the filesystem, so my question is, what do I need to do to the guest kernel / initrd image to make it recognize the virtual disk?

    Read the article

  • Best SQL Server Configuration with this hardware.

    - by DavidStein
    I just received my new SQL Server from Dell. The server will be serve approximately 15 OLTP databases which average 10GB in size. Here are the basic specs: Dell PowerEdge R510 with up to 12 Hot Swap HDDs,LED Intel Xeon E5649 2.53GHz, 12M Cache, 5.86 GT/s QPI, 6 core (Quantity of 2) 48GB Memory (6x8GB), 1333MHz Dual Ranked RDIMMs for 2 Processors, Optimized PERC H700 Integrated RAID Controller, 1GB NV Cache 300GB 15K RPM SA SCSI 6Gbps 3.5in Hotplug Hard Drive (Quantity of 4) 600GB 15K RPM SA SCSI 6Gbps 3.5in Hotplug Hard Drive (Quantity of 6) My first thought was to use 3 arrays. OS - Raid 1 - (2)300GB T-Log - Raid 1 (2)300GB DB - Raid 5 (5) 600GB Backup - (1) 600GB - non-raided. However, I could also do the following after purchasing one more drive for backup. OS and T-Log - Raid 10 - (4)300GB DB - Raid 10 (6)600GB The hard drive space is not an issue as the databases are not that large. I'm just trying to optimize the speed of the applications using these databases. So, what would you guys recommend?

    Read the article

  • I can't install Ubuntu on my Dell Inspiron 15R at all

    - by Kieran Rimmer
    I'm attempting to install Ubuntu 12.04LTS, 64 bit onto a Dell Inspiron 15R laptop. I've shrunk down one of the windows partitions and even used gparted to format the vacant space as ext4. However, the install disk simply does not present any options when it comes to the partitioning step. What I get is a non-responsive blank table As well as the above, I've changed the BIOS settings so that USB emulation is disabled (as per Can't install on Dell Inspiron 15R), and changed the SATA Operation setting to all three possible options. Anyway, the install CD will bring up the trial version of ubuntu, and if I open terminal and type sudo fdisk -l, I get this: Disk /dev/sda: 1000.2 GB, 1000204886016 bytes 255 heads, 63 sectors/track, 121601 cylinders, total 1953525168 sectors Units = sectors of 1 * 512 = 512 bytes Sector size (logical/physical): 512 bytes / 4096 bytes I/O size (minimum/optimal): 4096 bytes / 4096 bytes Disk identifier: 0xb4fd9215 Device Boot Start End Blocks Id System /dev/sda1 63 80324 40131 de Dell Utility Partition 1 does not start on physical sector boundary. /dev/sda2 * 81920 29044735 14481408 7 HPFS/NTFS/exFAT /dev/sda3 29044736 1005142015 488048640 7 HPFS/NTFS/exFAT /dev/sda4 1005154920 1953520064 474182572+ 83 Linux Disk /dev/sdb: 32.0 GB, 32017047552 bytes 255 heads, 63 sectors/track, 3892 cylinders, total 62533296 sectors Units = sectors of 1 * 512 = 512 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0xb4fd923d Device Boot Start End Blocks Id System /dev/sdb1 2048 16775167 8386560 84 OS/2 hidden C: drive If I type 'sudo parted -l', I get: Model: ATA WDC WD10JPVT-75A (scsi) Disk /dev/sda: 1000GB Sector size (logical/physical): 512B/4096B Partition Table: msdos Number Start End Size Type File system Flags 1 32.3kB 41.1MB 41.1MB primary fat16 diag 2 41.9MB 14.9GB 14.8GB primary ntfs boot 3 14.9GB 515GB 500GB primary ntfs 4 515GB 1000GB 486GB primary ext4 Model: ATA SAMSUNG SSD PM83 (scsi) Disk /dev/sdb: 32.0GB Sector size (logical/physical): 512B/512B Partition Table: msdos Number Start End Size Type File system Flags 1 1049kB 8589MB 8588MB primary Warning: Unable to open /dev/sr0 read-write (Read-only file system). /dev/sr0 has been opened read-only. Error: Can't have a partition outside the disk! I've also tried a Kubuntu 12.04 and Linuxmint install disks, wityh the same problem. I'm completely lost here. Cheers, Kieran

    Read the article

  • USB Flash not recognised by Windows and BIOS, but works fine in Linux

    - by bbalegere
    I have a Transcend JetFLash 2GB USB Drive.It was working fine and I had been using it occasionally. All of sudden it stopped working in all versions of Windows . The USB Drive is also not recognised by the BIOS.It does not show in the list of bootable devices.(It used show up in the list earlier) However the USB Drive works fine in my Linux Mint 11 OS. Running dmesg gives this [ 941.812192] usb 1-2: new high speed USB device using ehci_hcd and address 4 [ 941.936178] usb 1-2: device descriptor read/64, error -71 [ 942.164188] usb 1-2: device descriptor read/64, error -71 [ 942.380189] usb 1-2: new high speed USB device using ehci_hcd and address 5 [ 942.504138] usb 1-2: device descriptor read/64, error -71 [ 942.732179] usb 1-2: device descriptor read/64, error -71 [ 942.948154] usb 1-2: new high speed USB device using ehci_hcd and address 6 [ 943.364134] usb 1-2: device not accepting address 6, error -71 [ 943.476172] usb 1-2: new high speed USB device using ehci_hcd and address 7 [ 943.892140] usb 1-2: device not accepting address 7, error -71 [ 943.892191] hub 1-0:1.0: unable to enumerate USB device on port 2 [ 944.296190] usb 2-2: new full speed USB device using uhci_hcd and address 3 [ 944.438251] usb 2-2: not running at top speed; connect to a high speed hub [ 944.709928] usbcore: registered new interface driver uas [ 944.729999] Initializing USB Mass Storage driver... [ 944.730509] scsi6 : usb-storage 2-2:1.0 [ 944.730908] usbcore: registered new interface driver usb-storage [ 944.730917] USB Mass Storage support registered. [ 945.736320] scsi 6:0:0:0: Direct-Access JetFlash Transcend 2GB 8.07 PQ: 0 ANSI: 2 [ 945.744547] sd 6:0:0:0: Attached scsi generic sg1 type 0 [ 945.753316] sd 6:0:0:0: [sdb] 3944448 512-byte logical blocks: (2.01 GB/1.88 GiB) [ 945.758274] sd 6:0:0:0: [sdb] Write Protect is off [ 945.758288] sd 6:0:0:0: [sdb] Mode Sense: 03 00 00 00 [ 945.765167] sd 6:0:0:0: [sdb] No Caching mode page present [ 945.765181] sd 6:0:0:0: [sdb] Assuming drive cache: write through [ 945.784309] sd 6:0:0:0: [sdb] No Caching mode page present [ 945.784323] sd 6:0:0:0: [sdb] Assuming drive cache: write through [ 946.239512] sdb: sdb1 [ 946.257279] sd 6:0:0:0: [sdb] No Caching mode page present [ 946.257292] sd 6:0:0:0: [sdb] Assuming drive cache: write through [ 946.257302] sd 6:0:0:0: [sdb] Attached SCSI removable disk Looks like there is something wrong the USB Drive.It is not recognised in any computer running Windows. Is there any way to fix this? Any idea why this problem occurred ?

    Read the article

  • Bad disks in ancient server

    - by Joel Coel
    I have a 1998-era Netware 3.12 server that runs everything on our campus: general ledger, purchasing, payroll, student information, grades, you name it. The server has an Adaptec RAID controller with two volumes: RAID 1, 2 17GB scsi disks, Seagate ST318417W RAID 5, 3 4GB scsi disks, 2 Seagate ST34573W and 1 ST34572W. We are currently in the early stages of a project to replace this system, but you don't just jump into a new system like that and so I need to keep this server running until at least November 2011. This week we had not one but two hard drives fail. Thankfully they are from different volumes and we're able to keep running for the moment, but given the close nature of these failures I have serious doubts that I'll be able to avoid catastrophic failure from this server through the November target as is without restoring the RAID redundancy — it'll only take one more drive failure anywhere and I'm completely hosed. We are fortunate enough to have exact match "spares" lying around for both drives, but the spares are in unknown condition. I tried swapping just them in, but the RAID controller isn't smart enough to handle this and it renders the system unbootable. As for the RAID controller itself, there is utility I can get into during POST via a Ctrl-A shortcut, but I can't do much useful from there. To actually manage volumes I must first boot in to Netware, at which point I can use CI/O Array Management Software Version 2.0 to actually look at volume information. I suspect that the normal way to manage things is to boot from a special floppy with the controller software on it, but that floppy is long gone. Going through the options in the RAID software, I think the only supported way to replace a disk in an existing RAID volume is to physically add the disk, boot up and configure it as a "spare" for a volume, force the volume to use the spare to replace an existing down disk (and at this point I'm only guessing) so that the down disk becomes the spare, repair the volume, remove the spare from the volume, and then shut down and remove the disk. Then start all over for the other failed disk. All this amounts to a lot of downtime, assuming I can even make it work and that my spares are any good. As for finding reliable spares, I have no clue where to even begin looking to find a new 4GB scsi drive, or even which exact scsi system I'm looking for, as it's gone through a few different iterations over time. Another option is to migrate this to a virtual machine (hyper-v), but all previous attempts we've made in this area have failed to get very far. When this machine was installed I was just graduating from high school, and so it requires lower level knowledge of netware and dos than I ever developed, or if I did have since forgotten (I'm not exactly a dos neophyte, either). Part of my problem is this is a high-use server, and taking it down for a few days to figure things out isn't gonna fly very well. As for the question, I'm looking for anything that might be helpful in this situation: a recommendation on a place to find good spares from this era, personal experience repairing RAID volumes using a similar controller or building a hyper-v vm from an old netware server, a line on a floppy with better software for the RAID controller, recommendation on a good Novell consultant in Nebraska that would be able to put things right, a whole other option I haven't considered yet, etc. Update: For backups, we have good (recently verified via restore) backups of the data only -- nothing for the software that actually runs things. Update 2: Just a progress report that I currently have a working Netware 3.12 install in VMWare Virtual Server 2.0, thanks largely to the guide I found here: http://cerbulescubogdan.blogspot.com/2010/11/novell-netware-312-on-vmware.html The next steps are preparing empty netware volumes to match the additional volumes on my existing server, taking a dump of everything on the C:\ drive and netware volumes on my existing server, and figuring out from that information what modules need added to netware, installing my licenses (we do still have that disk, if it's any good), and moving data over. I have approval to bring the server down for a week after the first of the year (sadly not before), so, aside from creating empty volumes, the rest of the work will have to wait until then. Final Update (Jan 5, 2011): I was able to get spares working in both raid arrays without data loss this week. Both are now listed by the controller as "FAULT TOLLERANT" (yay!). I was also able to build on the progress from my last update and now have a functional "spare" server in VMWare Server 2.0. The spare can run and use our erp software, but I can't put it into production because I can't (yet) print from that box (and I have no idea why). Even so, this VM will do in a pinch if I have no other choice, and between it and the repaired RAID arrays I'm comfortable pushing on until I can junk the machine in November.

    Read the article

  • How to set up raid monitoring on a Adaptec AAC-RAID on a Dell?

    - by pjz
    I've got Debian on a Dell with an Adaptec RAID: AAC0: kernel 4.1-0[7417] AAC0: monitor 4.1-0[7417] AAC0: bios 4.1-0[7417] AAC0: serial 4edf09 scsi2 : aacraid Vendor: CERC Model: DATA 1 Rev: V1.0 Type: Direct-Access ANSI SCSI revision: 02 Vendor: CERC Model: Data 2 Rev: V1.0 Type: Direct-Access ANSI SCSI revision: 02 I've got it set up using the fine afacli tool (ick). Is there a way to get it to email me when there's an error? Do I need to hand-roll a script for this? what's the right version of the afacli tool to use? v4.1 gets SIGABRT and exits after I ask it to 'container list' or 'enclosure list' v2.8's enclosure commands don't work either Do I need to upgrade firmware? to what? from where? how?

    Read the article

  • Freebsd 7.2: View firmware version for disks?

    - by Stefan Lasiewski
    I'm running FreeBSD 7.2, with Seagate Cheetah (Model ST####) drives. We are having some problems with the SCSI drives on these machines. Our vendor says that updating the firmware on the drives may fix the problems, and a firmware update did seem to fix some SCSI problems on another FreeBSD host. How can I view the firmware version of these drives? I tried some tips from nixCraft, but nothing has worked so far. In dmesg, I see the Make and Model, but In Linux, this information is often in /var/log/dmesg (Although /var/log/dmesg is sometimes out of date), or I often find this information with something like sudo lshw -class disk, lshal or dmidecode.

    Read the article

  • Discs in DVD Drive not being read

    - by I Heart Ubuntu
    Does anyone have an experience with Ubuntu that is no longer reading discs in the DVD drive? This is my first time Ubuntu does not see the disc :| The disc is fine and works on my other Ubuntu computers. The drive is there and powered. I can even type in eject in a terminal and the drive will open. Using the command: sudo lshw -C disk I am able to see info about my drive too. Actually BOTH of my internal DVD drives cannot read discs anymore. If the output is not readable below, here is the info in pastebin. http://pastebin.com/GqqSCTPw *-cdrom:0 description: DVD writer product: DVD_RW ND-3500AG vendor: _NEC physical id: 0.0.0 bus info: scsi@0:0.0.0 logical name: /dev/cdrom1 logical name: /dev/cdrw1 logical name: /dev/dvd1 logical name: /dev/dvdrw1 logical name: /dev/scd0 logical name: /dev/sr0 version: 2.1B serial: [_NEC DVD_RW ND-3500AG2.1B06022300BT-LIGGY capabilities: removable audio cd-r cd-rw dvd dvd-r configuration: ansiversion=5 status=nodisc *-cdrom:1 description: DVD-RAM writer product: CDDVDW SH-S222A vendor: TSSTcorp physical id: 0.1.0 bus info: scsi@0:0.1.0 logical name: /dev/cdrom logical name: /dev/cdrw logical name: /dev/dvd logical name: /dev/dvdrw logical name: /dev/scd1 logical name: /dev/sr1 version: SB01 capabilities: removable audio cd-r cd-rw dvd dvd-r dvd-ram configuration: ansiversion=5 status=nodisc

    Read the article

  • Logon Failure: the target account name is incorrect after making a ghost image of a server

    - by cop1152
    I recently replaced a failing SCSI drive in a Windows 2000 server with an IDE drive. I made an image of the SCSI drive and Ghosted it. The purpose of the machine was to give out DHCP at one location and host a couple of files. When I restarted the machine with the new drive, DHCP appears to be working fine, but I cannot get to any of the shares. Instead, I get the following message when attempting to navigate using Explorer. Logon Failure: the target account name is incorrect It appears that this machine is not communicating with the main domain controller. Changes to user accounts (performed on the domain controller) are not replicated on this machine.

    Read the article

  • Unable to mount an LVM Hard-drive after upgrade

    - by Bruce Staples
    I imagine this is a basic gotcha ... but I can't see it. I have a system with 2(physical) harddrives. The boot system (/dev/sda) was running 10.04 & the second drive (/dev/sdb) was just a mounted filesystem. I did a clean load of Ubuntu 12.04 overwriting /dev/sda (not an upgrade) & now cannot mount the second drive. so I do not know what to enter it into the fstab ... I had expected to use: /dev/sdb /tera ext4 defaults 0 2 But even manual mounting fails (I also have tried various "-t" options on the off chance!) sudo mount -t ext4 /dev/sdb1 /tera mount: wrong fs type, bad option, bad superblock on /dev/sdb1, missing codepage or helper program, or other error In some cases useful info is found in syslog - try dmesg | tail or so Output from disk queries indicate that it is a Linux LVM & a healthy disk still. sudo lshw -C disk *-disk:0 description: ATA Disk product: WDC WD5000AACS-0 vendor: Western Digital physical id: 0 bus info: scsi@2:0.0.0 logical name: /dev/sda version: 01.0 serial: WD-WCASU1401098 size: 465GiB (500GB) capabilities: partitioned partitioned:dos configuration: ansiversion=5 signature=00015a55 *-disk:1 description: ATA Disk product: WDC WD10EADS-00L vendor: Western Digital physical id: 1 bus info: scsi@3:0.0.0 logical name: /dev/sdb version: 01.0 serial: WD-WCAU47836304 size: 931GiB (1TB) capabilities: partitioned partitioned:dos configuration: ansiversion=5 sudo fdisk -l Disk /dev/sda: 500.1 GB, 500106780160 bytes 255 heads, 63 sectors/track, 60801 cylinders, total 976771055 sectors Units = sectors of 1 * 512 = 512 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0x00015a55 Device Boot Start End Blocks Id System /dev/sda1 * 2048 972580863 486289408 83 Linux /dev/sda2 972582910 976769023 2093057 5 Extended /dev/sda5 972582912 976769023 2093056 82 Linux swap / Solaris Disk /dev/sdb: 1000.2 GB, 1000204886016 bytes 255 heads, 63 sectors/track, 121601 cylinders, total 1953525168 sectors Units = sectors of 1 * 512 = 512 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0x00000000 Device Boot Start End Blocks Id System /dev/sdb1 1 1953525167 976762583+ 8e Linux LVM LVM doesn't appear to be an option for mount or fstab. ... and here's a Smart data Screenshot from Disk Utility.

    Read the article

  • SATA controller installed but not working? (No drives show up/Don't see card's BIOS)

    - by johnnycakes
    Hi, I have an old Promise FastTrak S150 TX4 SATA controller card. I put it in an old machine running Windows Server 2003. I booted the machine. The new hardware was detected. I installed the drivers. So now in Device Manager under "SCSI and RAID Controllers" I see "Win Server 2003 Promise FastTrak S150 TX4 Controller" and "Win Server 2003 Promise RAID Console SCSI Processor Device" I previously had the card in a machine that is now dead. When I booted that machine, during the boot process I would see the card info displayed and the drives that were attached. Boot would finish and my drives would be available. When I boot this new machine I never see that screen/text. No hard drives are available/visible. What am I missing? Thanks.

    Read the article

  • Cannot view, use, or open CDs or DVDs in Ubuntu 12.04

    - by user67592
    I am fairly new to Ubuntu 12.04 and I have encountered a rather irritating problem. Whenever I insert a CD or DVD (whether it have data, music, movies, or nothing at all), nothing pops up saying "you have inserted a CD", "play with Rhythmbox?" etc. It doesn't show the CD in the launcher/dock or anything of the sort. This is especially peculiar because not only do I have a standard IDE built-in optical drive, but I have an external USB optical drive. Neither work. In addition, whenever I go to "Computer///" and I click (double click, right click, or even left click) on "CD/DVD Drive" nothing happens, when I right click and select "Open" nothing happens either [for either of the two drives (both are listed in Computer///)] And if I insert a blank disk and go to a disk burning program such as Brasero, and try to burn to the drive it detects no CDs or DVDs of any kind. I'm rather stumped and can't seem to find a question similar to this. :( Thanks for all your help in advance!! :) ~Preston Output of sudo lshw *-cdrom description: DVD-RAM writer product: CD/DVDW TS-H652M vendor: TSSTcorp physical id: 0.0.0 bus info: scsi@5:0.0.0 logical name: /dev/cdrom logical name: /dev/cdrw logical name: /dev/dvd logical name: /dev/dvdrw logical name: /dev/sr0 version: 0414 capabilities: removable audio cd-r cd-rw dvd dvd-r dvd-ram configuration: ansiversion=5 status=nodisc *-cdrom description: DVD reader product: DVD Writer 300n vendor: HP physical id: 0.0.0 bus info: scsi@4:0.0.0 logical name: /dev/cdrom2 logical name: /dev/cdrw2 logical name: /dev/dvd2 logical name: /dev/sr1 version: 1.25 serial: [ capabilities: removable audio cd-r cd-rw dvd configuration: status=nodisc

    Read the article

  • Backup tape compression

    - by pufferfish
    What things should I check to confirm that compression is actually happening on our tape backup system? Although the tapes are marked as 200G/520G (native/compressed) capacity, they seem to fill up before the 200G mark (some less than 100G). I'm using - Sony AIT-4 tape autochanger - Sony SDX4-200C (AIT-4) tapes - Ubuntu Lucid - Bacula I've tried checking hardware compression with: tapeinfo -f /dev/nst0, which gives Product Type: Tape Drive Vendor ID: 'SONY ' Product ID: 'SDX-900V ' Revision: '0102' Attached Changer API: No SerialNumber: '0001000036' MinBlock: 2 MaxBlock: 8388608 SCSI ID: 1 SCSI LUN: 0 Ready: yes BufferedMode: yes Medium Type: Not Loaded Density Code: 0x33 BlockSize: 0 DataCompEnabled: yes DataCompCapable: yes DataDeCompEnabled: yes CompType: 0x3 DeCompType: 0x3 BOP: yes Block Position: 0 Partition 0 Remaining Kbytes: 201778000 Partition 0 Size in Kbytes: 201779000 ActivePartition: 0 EarlyWarningSize: 0 NumPartitions: 0 MaxPartitions: 0 ... so I presume it's on. Notes: The Bacula documentation says hardware compression needs to be enable with "system tools such as mt"

    Read the article

  • How do I add a boot from cd option to yaboot?

    - by Sergiu
    So I'm dual-booting Ubuntu 12.04.1 on my iMac G5 powepc alongside Mac OS X and I want to add a boot cd option to yaboot because I'm trying to boot a scratched Mac OS X installation DVD that takes a while to read and the frst bootstrap moves on too fast. How do I edit the timeout for the first bootstrap anyways? So, my main question is, how do I add a cd booting option to yaboot and then, how doI boot it? The devalias from OpenFrmware tells me that 1 have 2 cd-rom instaled, on is /ht/pci@3/ata-6/disk@0 and the other on ends with a 1 instead of a zero. These are the contents of my yaboot.conf file: yaboot.conf generated by the Ubuntu installer run: "man yaboot.conf" for details. Do not make changes until you have!! see also: /usr/share/doc/yaboot/examples for example configurations. For a dual-boot menu, add one or more of: bsd=/dev/hdaX, macos=/dev/hdaY, macosx=/dev/hdaZ boot="/dev/disk/by-id/scsi-SATA_ST3160023AS_5MT1GCWA-part2" device=/ht@0,f2000000/pci@3/k2-sata-root@c/@0/@0 partition=4 root="UUID=798a048f-ee48-49e0-bba3-111aed8dee04" timeout=12000 install=/usr/lib/yaboot/yaboot magicboot=/usr/lib/yaboot/ofboot enablecdboot macosx="/dev/disk/by-id/scsi-SATA_ST3160023AS_5MT1GCWA-part3" image=/boot/vmlinux label=Linux read-only initrd=/boot/initrd.img append="quiet splash" What do I add here so that yaboot will boot from my cd in like 3 minutes after startup? Thanks!

    Read the article

  • My new hard drive won't automount on boot

    - by user518
    I installed a new hard drive right before installing the new Ubuntu 11.10 by reformatting, not upgrading. I was able to mount my drive, and partition it. It's a 1TB, and I was able to transfer all of my music, and videos to it. For some reason, it won't mount on boot, and I can't figure out how to manually mount it afterwards either. Here's my current /etc/fstab: # /etc/fstab: static file system information. # # Use 'blkid' to print the universally unique identifier for a # device; this may be used with UUID= as a more robust way to name devices # that works even if disks are added and removed. See fstab(5). # # proc /proc proc nodev,noexec,nosuid 0 0 # / was on /dev/sda1 during installation UUID=e0fbdf09-f9a0-4336-bac3-ba4dc6cfbcc0 / ext4 errors=remount-ro,user_xattr 0 1 # swap was on /dev/sda5 during installation UUID=adf15180-c84c-4309-bc9f-085fd7464f89 none swap sw 0 0 /dev/sdc1 /media/sdc1 ext4 defaults 0 0 The last line is what I added for my hard drive. Here's the output from sudo lshw -C disk: % sudo lshw -C disk ~ *-disk:0 description: ATA Disk product: ST3250310AS vendor: Seagate physical id: 0 bus info: scsi@2:0.0.0 logical name: /dev/sda version: 3.AD serial: 6RYBF2QE size: 232GiB (250GB) capabilities: partitioned partitioned:dos configuration: ansiversion=5 signature=000da204 *-cdrom description: DVD-RAM writer product: DVD+-RW DH-16A6S vendor: PLDS physical id: 0.0.0 bus info: scsi@4:0.0.0 logical name: /dev/cdrom logical name: /dev/cdrw logical name: /dev/dvd logical name: /dev/dvdrw logical name: /dev/scd0 logical name: /dev/sr0 version: YD11 capabilities: removable audio cd-r cd-rw dvd dvd-r dvd-ram configuration: ansiversion=5 status=nodisc

    Read the article

  • How to reliably map vSphere disks <-> Linux devices

    - by brianmcgee
    Task at hand After a virtual disk has been added to a Linux VM on vSphere 5, we need to identify the disks in order to automate the LVM storage provision. The virtual disks may reside on different datastores (e.g. sas or flash) and although they may be of the same size, their speed may vary. So I need a method to map the vSphere disks to Linux devices. Ideas Through the vSphere API, I am able to get the device info: Data Object Type: VirtualDiskFlatVer2BackingInfo Parent Managed Object ID: vm-230 Property Path: config.hardware.device[2000].backing Properties Name Type Value ChangeId string Unset contentId string "d58ec8c12486ea55c6f6d913642e1801" datastore ManagedObjectReference:Datastore datastore-216 (W5-CFAS012-Hybrid-CL20-004) deltaDiskFormat string "redoLogFormat" deltaGrainSize int Unset digestEnabled boolean false diskMode string "persistent" dynamicProperty DynamicProperty[] Unset dynamicType string Unset eagerlyScrub boolean Unset fileName string "[W5-CFAS012-Hybrid-CL20-004] l****9-000001.vmdk" parent VirtualDiskFlatVer2BackingInfo parent split boolean false thinProvisioned boolean false uuid string "6000C295-ab45-704e-9497-b25d2ba8dc00" writeThrough boolean false And on Linux I may read the uuid strings: [root@lx***** ~]# lsscsi -t [1:0:0:0] cd/dvd ata: /dev/sr0 [2:0:0:0] disk sas:0x5000c295ab45704e /dev/sda [3:0:0:0] disk sas:0x5000c2932dfa693f /dev/sdb [3:0:1:0] disk sas:0x5000c29dcd64314a /dev/sdc As you can see, the uuid string of disk /dev/sda looks somehow familiar to the string that is visible in the VMware API. Only the first hex digit is different (5 vs. 6) and it is only present to the third hyphen. So this looks promising... Alternative idea Select disks by controller. But is it reliable that the ascending SCSI Id also matches the next vSphere virtual disk? What happens if I add another DVD-ROM drive / USB Thumb drive? This will probably introduce new SCSI devices in between. Thats the cause why I think I will discard this idea. Questions Does someone know an easier method to map vSphere disks and Linux devices? Can someone explain the differences in the uuid strings? (I think this has something to do with SAS adressing initiator and target... WWN like...) May I reliably map devices by using those uuid strings? How about SCSI virtual disks? There is no uuid visible then... This task seems to be so obvious. Why doesn't Vmware think about this and simply add a way to query the disk mapping via Vmware Tools?

    Read the article

  • External USB 3 drive not recognized

    - by ilan123
    Ubuntu 12.10 64 bit seems not to recognize my external hard disk. It is a Vantec NST-310S3 external disk enclosure with a WD 3TB drive. The disk has two NTFS partitions. My PC is a dual boot system. Under Windows 7 the hard disk works fine but I can't make it work with Ubuntu. When the drive is connected to the PC then the command sudo fdisk -l seems to hang forever. Below are the output of lsusb and cat /proc/partitions without the external drive and then with it connected. I added also the last lines of the dmesg command at the end. First without the drive: ilan@linux:~$ lsusb Bus 001 Device 002: ID 8087:0024 Intel Corp. Integrated Rate Matching Hub Bus 002 Device 002: ID 8087:0024 Intel Corp. Integrated Rate Matching Hub Bus 001 Device 001: ID 1d6b:0002 Linux Foundation 2.0 root hub Bus 002 Device 001: ID 1d6b:0002 Linux Foundation 2.0 root hub Bus 003 Device 001: ID 1d6b:0002 Linux Foundation 2.0 root hub Bus 004 Device 001: ID 1d6b:0003 Linux Foundation 3.0 root hub Bus 001 Device 003: ID 13ba:0017 Unknown PS/2 Keyboard+Mouse Adapter Bus 001 Device 004: ID 046d:c50e Logitech, Inc. Cordless Mouse Receiver Bus 001 Device 005: ID 0ac8:3420 Z-Star Microelectronics Corp. Venus USB2.0 Camera ilan@linux:~$ cat /proc/partitions major minor #blocks name 8 0 1953514584 sda 8 1 102400 sda1 8 2 629043200 sda2 8 3 367001600 sda3 8 4 1 sda4 8 5 471859200 sda5 8 6 157286400 sda6 8 7 324115456 sda7 8 8 4101120 sda8 11 0 1048575 sr0 Second with the USB 3 drive: ilan@linux:~$ lsusb Bus 001 Device 002: ID 8087:0024 Intel Corp. Integrated Rate Matching Hub Bus 002 Device 002: ID 8087:0024 Intel Corp. Integrated Rate Matching Hub Bus 004 Device 002: ID 174c:55aa ASMedia Technology Inc. Bus 001 Device 001: ID 1d6b:0002 Linux Foundation 2.0 root hub Bus 002 Device 001: ID 1d6b:0002 Linux Foundation 2.0 root hub Bus 003 Device 001: ID 1d6b:0002 Linux Foundation 2.0 root hub Bus 004 Device 001: ID 1d6b:0003 Linux Foundation 3.0 root hub Bus 001 Device 003: ID 13ba:0017 Unknown PS/2 Keyboard+Mouse Adapter Bus 001 Device 004: ID 046d:c50e Logitech, Inc. Cordless Mouse Receiver Bus 001 Device 005: ID 0ac8:3420 Z-Star Microelectronics Corp. Venus USB2.0 Camera ilan@linux:~$ cat /proc/partitions major minor #blocks name 8 0 1953514584 sda 8 1 102400 sda1 8 2 629043200 sda2 8 3 367001600 sda3 8 4 1 sda4 8 5 471859200 sda5 8 6 157286400 sda6 8 7 324115456 sda7 8 8 4101120 sda8 11 0 1048575 sr0 8 16 2930266584 sdb ilan@linux:~$ lsusb -v -s 004:002 Bus 004 Device 002: ID 174c:55aa ASMedia Technology Inc. Couldn't open device, some information will be missing Device Descriptor: bLength 18 bDescriptorType 1 bcdUSB 3.00 bDeviceClass 0 (Defined at Interface level) bDeviceSubClass 0 bDeviceProtocol 0 bMaxPacketSize0 9 idVendor 0x174c ASMedia Technology Inc. idProduct 0x55aa bcdDevice 1.00 iManufacturer 2 iProduct 3 iSerial 1 bNumConfigurations 1 Configuration Descriptor: bLength 9 bDescriptorType 2 wTotalLength 44 bNumInterfaces 1 bConfigurationValue 1 iConfiguration 0 bmAttributes 0xc0 Self Powered MaxPower 0mA Interface Descriptor: bLength 9 bDescriptorType 4 bInterfaceNumber 0 bAlternateSetting 0 bNumEndpoints 2 bInterfaceClass 8 Mass Storage bInterfaceSubClass 6 SCSI bInterfaceProtocol 80 Bulk-Only iInterface 0 Endpoint Descriptor: bLength 7 bDescriptorType 5 bEndpointAddress 0x81 EP 1 IN bmAttributes 2 Transfer Type Bulk Synch Type None Usage Type Data wMaxPacketSize 0x0400 1x 1024 bytes bInterval 0 bMaxBurst 15 Endpoint Descriptor: bLength 7 bDescriptorType 5 bEndpointAddress 0x02 EP 2 OUT bmAttributes 2 Transfer Type Bulk Synch Type None Usage Type Data wMaxPacketSize 0x0400 1x 1024 bytes bInterval 0 bMaxBurst 15 ilan@linux:~$ sudo fdisk -l [sudo] password for ilan: Disk /dev/sda: 2000.4 GB, 2000398934016 bytes 255 heads, 63 sectors/track, 243201 cylinders, total 3907029168 sectors Units = sectors of 1 * 512 = 512 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0xf1b4f1ee Device Boot Start End Blocks Id System /dev/sda1 * 2048 206847 102400 7 HPFS/NTFS/exFAT /dev/sda2 206848 1258293247 629043200 7 HPFS/NTFS/exFAT /dev/sda3 1258293248 1992296447 367001600 7 HPFS/NTFS/exFAT /dev/sda4 1992298494 3907028991 957365249 f W95 Ext'd (LBA) /dev/sda5 1992298496 2936016895 471859200 7 HPFS/NTFS/exFAT /dev/sda6 2936018944 3250591743 157286400 7 HPFS/NTFS/exFAT /dev/sda7 3250593792 3898824703 324115456 83 Linux /dev/sda8 3898826752 3907028991 4101120 82 Linux swap / Solaris dmesg output after connecting the external drive: [ 23.740567] e1000e: eth0 NIC Link is Up 1000 Mbps Full Duplex, Flow Control: Rx/Tx [ 23.740786] IPv6: ADDRCONF(NETDEV_CHANGE): eth0: link becomes ready [ 49.144673] usb 4-1: >new SuperSpeed USB device number 2 using xhci_hcd [ 49.163039] usb 4-1: >Parent hub missing LPM exit latency info. Power management will be impacted. [ 49.166789] usb 4-1: >New USB device found, idVendor=174c, idProduct=55aa [ 49.166793] usb 4-1: >New USB device strings: Mfr=2, Product=3, SerialNumber=1 [ 49.166796] usb 4-1: >Product: AS2105 [ 49.166799] usb 4-1: >Manufacturer: ASMedia [ 49.166801] usb 4-1: >SerialNumber: 0123456789ABCDEF [ 49.206372] usbcore: registered new interface driver uas [ 49.228891] Initializing USB Mass Storage driver... [ 49.229042] scsi6 : usb-storage 4-1:1.0 [ 49.229115] usbcore: registered new interface driver usb-storage [ 49.229116] USB Mass Storage support registered. [ 64.045528] scsi 6:0:0:0: >Direct-Access WDC WD30 EZRX-00MMMB0 80.0 PQ: 0 ANSI: 0 [ 64.046224] sd 6:0:0:0: >Attached scsi generic sg2 type 0 [ 64.046881] sd 6:0:0:0: >[sdb] Very big device. Trying to use READ CAPACITY(16). [ 64.047610] sd 6:0:0:0: >[sdb] 5860533168 512-byte logical blocks: (3.00 TB/2.72 TiB) [ 64.048368] sd 6:0:0:0: >[sdb] Write Protect is off [ 64.048373] sd 6:0:0:0: >[sdb] Mode Sense: 23 00 00 00 [ 64.048984] sd 6:0:0:0: >[sdb] No Caching mode page present [ 64.048987] sd 6:0:0:0: >[sdb] Assuming drive cache: write through [ 64.049297] sd 6:0:0:0: >[sdb] Very big device. Trying to use READ CAPACITY(16). [ 64.050942] sd 6:0:0:0: >[sdb] No Caching mode page present [ 64.050944] sd 6:0:0:0: >[sdb] Assuming drive cache: write through [ 94.245006] usb 4-1: >reset SuperSpeed USB device number 2 using xhci_hcd [ 94.262553] usb 4-1: >Parent hub missing LPM exit latency info. Power management will be impacted. [ 94.263805] xhci_hcd 0000:03:00.0: >xHCI xhci_drop_endpoint called with disabled ep ffff8800d37d1c00 [ 94.263808] xhci_hcd 0000:03:00.0: >xHCI xhci_drop_endpoint called with disabled ep ffff8800d37d1c40 [ 125.262722] usb 4-1: >reset SuperSpeed USB device number 2 using xhci_hcd [ 125.280304] usb 4-1: >Parent hub missing LPM exit latency info. Power management will be impacted. [ 125.281511] xhci_hcd 0000:03:00.0: >xHCI xhci_drop_endpoint called with disabled ep ffff8800d37d1c00 [ 125.281516] xhci_hcd 0000:03:00.0: >xHCI xhci_drop_endpoint called with disabled ep ffff8800d37d1c40

    Read the article

  • SPARC T5-4 LDoms for RAC and WebLogic Clusters

    - by Jeff Taylor-Oracle
    I wanted to use two Oracle SPARC T5-4 servers to simultaneously host both Oracle RAC and a WebLogic Server Cluster. I chose to use Oracle VM Server for SPARC to create a cluster like this: There are plenty of trade offs and decisions that need to be made, for example: Rather than configuring the system by hand, you might want to use an Oracle SuperCluster T5-8 My configuration is similar to jsavit's: Availability Best Practices - Example configuring a T5-8 but I chose to ignore some of the advice. Maybe I should have included an  alternate service domain, but I decided that I already had enough redundancy Both Oracle SPARC T5-4 servers were to be configured like this: Cntl 0.25  4  64GB                     App LDom                    2.75 CPU's                                        44 cores                                          704 GB              DB LDom      One CPU         16 cores         256 GB   The systems started with everything in the primary domain: # ldm list NAME             STATE      FLAGS   CONS    VCPU  MEMORY   UTIL  NORM  UPTIME primary          active     -n-c--  UART    512   1023G    0.0%  0.0%  11m # ldm list-spconfig factory-default [current] primary # ldm list -o core,memory,physio NAME              primary           CORE     CID    CPUSET     0      (0, 1, 2, 3, 4, 5, 6, 7)     1      (8, 9, 10, 11, 12, 13, 14, 15)     2      (16, 17, 18, 19, 20, 21, 22, 23) -- SNIP     62     (496, 497, 498, 499, 500, 501, 502, 503)     63     (504, 505, 506, 507, 508, 509, 510, 511) MEMORY     RA               PA               SIZE                 0x30000000       0x30000000       255G     0x80000000000    0x80000000000    256G     0x100000000000   0x100000000000   256G     0x180000000000   0x180000000000   256G # Give this memory block to the DB LDom IO     DEVICE                           PSEUDONYM        OPTIONS     pci@300                          pci_0                pci@340                          pci_1                pci@380                          pci_2                pci@3c0                          pci_3                pci@400                          pci_4                pci@440                          pci_5                pci@480                          pci_6                pci@4c0                          pci_7                pci@300/pci@1/pci@0/pci@6        /SYS/RCSA/PCIE1     pci@300/pci@1/pci@0/pci@c        /SYS/RCSA/PCIE2     pci@300/pci@1/pci@0/pci@4/pci@0/pci@c /SYS/MB/SASHBA0     pci@300/pci@1/pci@0/pci@4/pci@0/pci@8 /SYS/RIO/NET0        pci@340/pci@1/pci@0/pci@6        /SYS/RCSA/PCIE3     pci@340/pci@1/pci@0/pci@c        /SYS/RCSA/PCIE4     pci@380/pci@1/pci@0/pci@a        /SYS/RCSA/PCIE9     pci@380/pci@1/pci@0/pci@4        /SYS/RCSA/PCIE10     pci@3c0/pci@1/pci@0/pci@e        /SYS/RCSA/PCIE11     pci@3c0/pci@1/pci@0/pci@8        /SYS/RCSA/PCIE12     pci@400/pci@1/pci@0/pci@e        /SYS/RCSA/PCIE5     pci@400/pci@1/pci@0/pci@8        /SYS/RCSA/PCIE6     pci@440/pci@1/pci@0/pci@e        /SYS/RCSA/PCIE7     pci@440/pci@1/pci@0/pci@8        /SYS/RCSA/PCIE8     pci@480/pci@1/pci@0/pci@a        /SYS/RCSA/PCIE13     pci@480/pci@1/pci@0/pci@4        /SYS/RCSA/PCIE14     pci@4c0/pci@1/pci@0/pci@8        /SYS/RCSA/PCIE15     pci@4c0/pci@1/pci@0/pci@4        /SYS/RCSA/PCIE16     pci@4c0/pci@1/pci@0/pci@c/pci@0/pci@c /SYS/MB/SASHBA1     pci@4c0/pci@1/pci@0/pci@c/pci@0/pci@4 /SYS/RIO/NET2    Added an additional service processor configuration: # ldm add-spconfig split # ldm list-spconfig factory-default primary split [current] And removed many of the resources from the primary domain: # ldm start-reconf primary # ldm set-core 4 primary # ldm set-memory 32G primary # ldm rm-io pci@340 primary # ldm rm-io pci@380 primary # ldm rm-io pci@3c0 primary # ldm rm-io pci@400 primary # ldm rm-io pci@440 primary # ldm rm-io pci@480 primary # ldm rm-io pci@4c0 primary # init 6 Needed to add resources to the guest domains: # ldm add-domain db # ldm set-core cid=`seq -s"," 48 63` db # ldm add-memory mblock=0x180000000000:256G db # ldm add-io pci@480 db # ldm add-io pci@4c0 db # ldm add-domain app # ldm set-core 44 app # ldm set-memory 704G  app # ldm add-io pci@340 app # ldm add-io pci@380 app # ldm add-io pci@3c0 app # ldm add-io pci@400 app # ldm add-io pci@440 app Needed to set up services: # ldm add-vds primary-vds0 primary # ldm add-vcc port-range=5000-5100 primary-vcc0 primary Needed to add a virtual network port for the WebLogic application domain: # ipadm NAME              CLASS/TYPE STATE        UNDER      ADDR lo0               loopback   ok           --         --    lo0/v4         static     ok           --         ...    lo0/v6         static     ok           --         ... net0              ip         ok           --         ...    net0/v4        static     ok           --         xxx.xxx.xxx.xxx/24    net0/v6        addrconf   ok           --         ....    net0/v6        addrconf   ok           --         ... net8              ip         ok           --         --    net8/v4        static     ok           --         ... # dladm show-phys LINK              MEDIA                STATE      SPEED  DUPLEX    DEVICE net1              Ethernet             unknown    0      unknown   ixgbe1 net0              Ethernet             up         1000   full      ixgbe0 net8              Ethernet             up         10     full      usbecm2 # ldm add-vsw net-dev=net0 primary-vsw0 primary # ldm add-vnet vnet1 primary-vsw0 app Needed to add a virtual disk to the WebLogic application domain: # format Searching for disks...done AVAILABLE DISK SELECTIONS:        0. c0t5000CCA02505F874d0 <HITACHI-H106060SDSUN600G-A2B0-558.91GB>           /scsi_vhci/disk@g5000cca02505f874           /dev/chassis/SPARC_T5-4.AK00084038/SYS/SASBP0/HDD0/disk        1. c0t5000CCA02506C468d0 <HITACHI-H106060SDSUN600G-A2B0-558.91GB>           /scsi_vhci/disk@g5000cca02506c468           /dev/chassis/SPARC_T5-4.AK00084038/SYS/SASBP0/HDD1/disk        2. c0t5000CCA025067E5Cd0 <HITACHI-H106060SDSUN600G-A2B0-558.91GB>           /scsi_vhci/disk@g5000cca025067e5c           /dev/chassis/SPARC_T5-4.AK00084038/SYS/SASBP0/HDD2/disk        3. c0t5000CCA02506C258d0 <HITACHI-H106060SDSUN600G-A2B0-558.91GB>           /scsi_vhci/disk@g5000cca02506c258           /dev/chassis/SPARC_T5-4.AK00084038/SYS/SASBP0/HDD3/disk Specify disk (enter its number): ^C # ldm add-vdsdev /dev/dsk/c0t5000CCA02506C468d0s2 HDD1@primary-vds0 # ldm add-vdisk HDD1 HDD1@primary-vds0 app Add some additional spice to the pot: # ldm set-variable auto-boot\\?=false db # ldm set-variable auto-boot\\?=false app # ldm set-var boot-device=HDD1 app Bind the logical domains: # ldm bind db # ldm bind app At the end of the process, the system is set up like this: # ldm list -o core,memory,physio NAME             primary          CORE     CID    CPUSET     0      (0, 1, 2, 3, 4, 5, 6, 7)     1      (8, 9, 10, 11, 12, 13, 14, 15)     2      (16, 17, 18, 19, 20, 21, 22, 23)     3      (24, 25, 26, 27, 28, 29, 30, 31) MEMORY     RA               PA               SIZE                0x30000000       0x30000000       32G IO     DEVICE                           PSEUDONYM        OPTIONS     pci@300                          pci_0               pci@300/pci@1/pci@0/pci@6        /SYS/RCSA/PCIE1     pci@300/pci@1/pci@0/pci@c        /SYS/RCSA/PCIE2     pci@300/pci@1/pci@0/pci@4/pci@0/pci@c /SYS/MB/SASHBA0     pci@300/pci@1/pci@0/pci@4/pci@0/pci@8 /SYS/RIO/NET0   ------------------------------------------------------------------------------ NAME             app              CORE     CID    CPUSET     4      (32, 33, 34, 35, 36, 37, 38, 39)     5      (40, 41, 42, 43, 44, 45, 46, 47)     6      (48, 49, 50, 51, 52, 53, 54, 55)     7      (56, 57, 58, 59, 60, 61, 62, 63)     8      (64, 65, 66, 67, 68, 69, 70, 71)     9      (72, 73, 74, 75, 76, 77, 78, 79)     10     (80, 81, 82, 83, 84, 85, 86, 87)     11     (88, 89, 90, 91, 92, 93, 94, 95)     12     (96, 97, 98, 99, 100, 101, 102, 103)     13     (104, 105, 106, 107, 108, 109, 110, 111)     14     (112, 113, 114, 115, 116, 117, 118, 119)     15     (120, 121, 122, 123, 124, 125, 126, 127)     16     (128, 129, 130, 131, 132, 133, 134, 135)     17     (136, 137, 138, 139, 140, 141, 142, 143)     18     (144, 145, 146, 147, 148, 149, 150, 151)     19     (152, 153, 154, 155, 156, 157, 158, 159)     20     (160, 161, 162, 163, 164, 165, 166, 167)     21     (168, 169, 170, 171, 172, 173, 174, 175)     22     (176, 177, 178, 179, 180, 181, 182, 183)     23     (184, 185, 186, 187, 188, 189, 190, 191)     24     (192, 193, 194, 195, 196, 197, 198, 199)     25     (200, 201, 202, 203, 204, 205, 206, 207)     26     (208, 209, 210, 211, 212, 213, 214, 215)     27     (216, 217, 218, 219, 220, 221, 222, 223)     28     (224, 225, 226, 227, 228, 229, 230, 231)     29     (232, 233, 234, 235, 236, 237, 238, 239)     30     (240, 241, 242, 243, 244, 245, 246, 247)     31     (248, 249, 250, 251, 252, 253, 254, 255)     32     (256, 257, 258, 259, 260, 261, 262, 263)     33     (264, 265, 266, 267, 268, 269, 270, 271)     34     (272, 273, 274, 275, 276, 277, 278, 279)     35     (280, 281, 282, 283, 284, 285, 286, 287)     36     (288, 289, 290, 291, 292, 293, 294, 295)     37     (296, 297, 298, 299, 300, 301, 302, 303)     38     (304, 305, 306, 307, 308, 309, 310, 311)     39     (312, 313, 314, 315, 316, 317, 318, 319)     40     (320, 321, 322, 323, 324, 325, 326, 327)     41     (328, 329, 330, 331, 332, 333, 334, 335)     42     (336, 337, 338, 339, 340, 341, 342, 343)     43     (344, 345, 346, 347, 348, 349, 350, 351)     44     (352, 353, 354, 355, 356, 357, 358, 359)     45     (360, 361, 362, 363, 364, 365, 366, 367)     46     (368, 369, 370, 371, 372, 373, 374, 375)     47     (376, 377, 378, 379, 380, 381, 382, 383) MEMORY     RA               PA               SIZE                0x30000000       0x830000000      192G     0x4000000000     0x80000000000    256G     0x8080000000     0x100000000000   256G IO     DEVICE                           PSEUDONYM        OPTIONS     pci@340                          pci_1               pci@380                          pci_2               pci@3c0                          pci_3               pci@400                          pci_4               pci@440                          pci_5               pci@340/pci@1/pci@0/pci@6        /SYS/RCSA/PCIE3     pci@340/pci@1/pci@0/pci@c        /SYS/RCSA/PCIE4     pci@380/pci@1/pci@0/pci@a        /SYS/RCSA/PCIE9     pci@380/pci@1/pci@0/pci@4        /SYS/RCSA/PCIE10     pci@3c0/pci@1/pci@0/pci@e        /SYS/RCSA/PCIE11     pci@3c0/pci@1/pci@0/pci@8        /SYS/RCSA/PCIE12     pci@400/pci@1/pci@0/pci@e        /SYS/RCSA/PCIE5     pci@400/pci@1/pci@0/pci@8        /SYS/RCSA/PCIE6     pci@440/pci@1/pci@0/pci@e        /SYS/RCSA/PCIE7     pci@440/pci@1/pci@0/pci@8        /SYS/RCSA/PCIE8 ------------------------------------------------------------------------------ NAME             db               CORE     CID    CPUSET     48     (384, 385, 386, 387, 388, 389, 390, 391)     49     (392, 393, 394, 395, 396, 397, 398, 399)     50     (400, 401, 402, 403, 404, 405, 406, 407)     51     (408, 409, 410, 411, 412, 413, 414, 415)     52     (416, 417, 418, 419, 420, 421, 422, 423)     53     (424, 425, 426, 427, 428, 429, 430, 431)     54     (432, 433, 434, 435, 436, 437, 438, 439)     55     (440, 441, 442, 443, 444, 445, 446, 447)     56     (448, 449, 450, 451, 452, 453, 454, 455)     57     (456, 457, 458, 459, 460, 461, 462, 463)     58     (464, 465, 466, 467, 468, 469, 470, 471)     59     (472, 473, 474, 475, 476, 477, 478, 479)     60     (480, 481, 482, 483, 484, 485, 486, 487)     61     (488, 489, 490, 491, 492, 493, 494, 495)     62     (496, 497, 498, 499, 500, 501, 502, 503)     63     (504, 505, 506, 507, 508, 509, 510, 511) MEMORY     RA               PA               SIZE                0x80000000       0x180000000000   256G IO     DEVICE                           PSEUDONYM        OPTIONS     pci@480                          pci_6               pci@4c0                          pci_7               pci@480/pci@1/pci@0/pci@a        /SYS/RCSA/PCIE13     pci@480/pci@1/pci@0/pci@4        /SYS/RCSA/PCIE14     pci@4c0/pci@1/pci@0/pci@8        /SYS/RCSA/PCIE15     pci@4c0/pci@1/pci@0/pci@4        /SYS/RCSA/PCIE16     pci@4c0/pci@1/pci@0/pci@c/pci@0/pci@c /SYS/MB/SASHBA1     pci@4c0/pci@1/pci@0/pci@c/pci@0/pci@4 /SYS/RIO/NET2   Start the domains: # ldm start app LDom app started # ldm start db LDom db started Make sure to start the vntsd service that was created, above. # svcs -a | grep ldo disabled        8:38:38 svc:/ldoms/vntsd:default online          8:38:58 svc:/ldoms/agents:default online          8:39:25 svc:/ldoms/ldmd:default # svcadm enable vntsd Now use the MAC address to configure the Solaris 11 Automated Installation. Database Logical Domain # telnet localhost 5000 {0} ok devalias screen                   /pci@4c0/pci@1/pci@0/pci@c/pci@0/pci@7/display@0 disk7                    /pci@4c0/pci@1/pci@0/pci@c/pci@0/pci@c/scsi@0/disk@p3 disk6                    /pci@4c0/pci@1/pci@0/pci@c/pci@0/pci@c/scsi@0/disk@p2 disk5                    /pci@4c0/pci@1/pci@0/pci@c/pci@0/pci@c/scsi@0/disk@p1 disk4                    /pci@4c0/pci@1/pci@0/pci@c/pci@0/pci@c/scsi@0/disk@p0 scsi1                    /pci@4c0/pci@1/pci@0/pci@c/pci@0/pci@c/scsi@0 net3                     /pci@4c0/pci@1/pci@0/pci@c/pci@0/pci@4/network@0,1 net2                     /pci@4c0/pci@1/pci@0/pci@c/pci@0/pci@4/network@0 virtual-console          /virtual-devices/console@1 name                     aliases {0} ok boot net2 Boot device: /pci@4c0/pci@1/pci@0/pci@c/pci@0/pci@4/network@0  File and args: 1000 Mbps full duplex Link up Requesting Internet Address for xx:xx:xx:xx:xx:xx Requesting Internet Address for xx:xx:xx:xx:xx:xx WLS Logical Domain # telnet localhost 5001 {0} ok devalias hdd1                     /virtual-devices@100/channel-devices@200/disk@0 vnet1                    /virtual-devices@100/channel-devices@200/network@0 net                      /virtual-devices@100/channel-devices@200/network@0 disk                     /virtual-devices@100/channel-devices@200/disk@0 virtual-console          /virtual-devices/console@1 name                     aliases {0} ok boot net Boot device: /virtual-devices@100/channel-devices@200/network@0  File and args: Requesting Internet Address for xx:xx:xx:xx:xx:xx Requesting Internet Address for xx:xx:xx:xx:xx:xx Repeat the process for the second SPARC T5-4, install Solaris, RAC and WebLogic Cluster, and you are ready to go. Maybe buying a SuperCluster would have been easier.

    Read the article

  • 2-Bay External HDD Enclosure in JBOD mode fails to detect both drives (Linux & Windows)

    - by mgc8888
    I recently purchased a couple of USB 3.0 External HDD Enclosures to use for storage and backup; the idea was to have one act as backup to the other, with 4 x 3TB drives in total. However, the second drive in each is not accessible in either Linux nor Windows, and I could not determine the reason. 1. Situation The two enclosures are slightly different (couldn't find them in stock at the same time) yet from many little details appear to be the same Chinese base design with a tweaked outer shell. The models are: Sharkoon 2-Bay RAID Box Fantec MR-35DU3 The drives are Seagate 3TB Barracuda ST33000651AS, firmware CC44, all identical. From reading manuals and online sources, I determined that JBOD would be the optimal setup for my needs -- addressing the two drives separately in each enclosure would be important, making it easy to swap drives and mix&match them if needed; all the other modes implied the controller doing a combination of the drives. The software used was Debian GNU/Linux - testing/wheezy - kernel 2.6.39-2 and Windows 7 Ultimate. 2. Description of the problem Now, here comes the problem: every time I connect either of the enclosures to a PC using the supplied cable (tried a different one as well), only the HDD in the top bay is readable, the one below is detected yet errors out in various ways. According to the manuals, it should not happen: in JBOD, the system should be able to "see" two separate drives upon connection. This happens with both enclosures and any combination of HDDs (i.e. if I swap them, the same thing happens), so the HDDs are good and I think so are the enclosures (two different companies making similar products that failed in an identical fashion would be very unlikely). The top HDD can be used fine every time, I actually tried a speed test from Linux and got about 150MiB/s reads, so all is working as it should; the one below refuses to work every time. So the failure is consistent. To make sure this was not some obscure Linux bug, I tried the same under Windows 7, and the system also only created one drive letter for a drive of 3TB size (so it was only seeing one instead of both). Placing an older, known good, 2TB drive in the top bay made that the one recognised, so we have the same issue under Windows as well. Log entries under Linux (tested here with a 3TB and a 2TB drive so I could differentiate them; either one works in the top enclosure, in the test setup the 3TB one is on top). You can see them being detected, the top one is ok, but for the bottom one only errors: Jul 19 23:28:15 media kernel: [260150.582436] usb 6-1: New USB device found, idVendor=1ca1, idProduct=18ae Jul 19 23:28:15 media kernel: [260150.582440] usb 6-1: New USB device strings: Mfr=1, Product=2, SerialNumber=3 Jul 19 23:28:15 media kernel: [260150.582442] usb 6-1: Product: Usb Sata Bridge Jul 19 23:28:15 media kernel: [260150.582444] usb 6-1: Manufacturer: SYMWAVE Jul 19 23:28:15 media kernel: [260150.582446] usb 6-1: SerialNumber: 39584B304C4E3441 Jul 19 23:28:15 media kernel: [260150.870412] scsi11 : usb-storage 6-1:1.0 Jul 19 23:28:16 media kernel: [260151.882087] scsi 11:0:0:0: Direct-Access SYMWAVE ST33000651AS CC44 PQ: 0 ANSI: 4 Jul 19 23:28:16 media kernel: [260151.882242] scsi 11:0:0:1: Direct-Access SYMWAVE ST32000641AS CC12 PQ: 0 ANSI: 4 Jul 19 23:28:16 media kernel: [260151.882677] sd 11:0:0:0: Attached scsi generic sg2 type 0 Jul 19 23:28:16 media kernel: [260151.882774] sd 11:0:0:0: [sdb] Very big device. Trying to use READ CAPACITY(16). Jul 19 23:28:16 media kernel: [260151.882857] sd 11:0:0:1: Attached scsi generic sg3 type 0 Jul 19 23:28:16 media kernel: [260151.882893] sd 11:0:0:0: [sdb] 5860533168 512-byte logical blocks: (3.00 TB/2.72 TiB) Jul 19 23:28:16 media kernel: [260151.883085] xhci_hcd 0000:03:00.0: WARN: Stalled endpoint Jul 19 23:28:16 media kernel: [260151.883582] sd 11:0:0:0: [sdb] Write Protect is off Jul 19 23:28:16 media kernel: [260151.883961] sd 11:0:0:1: [sdc] 3907029168 512-byte logical blocks: (2.00 TB/1.81 TiB) Jul 19 23:28:16 media kernel: [260151.884145] xhci_hcd 0000:03:00.0: WARN: Stalled endpoint Jul 19 23:28:16 media kernel: [260151.884570] sd 11:0:0:1: [sdc] Write Protect is off Jul 19 23:28:16 media kernel: [260151.884855] sd 11:0:0:0: [sdb] Very big device. Trying to use READ CAPACITY(16). Jul 19 23:28:16 media kernel: [260151.885286] xhci_hcd 0000:03:00.0: WARN: Stalled endpoint Jul 19 23:28:16 media kernel: [260151.885807] xhci_hcd 0000:03:00.0: WARN: Stalled endpoint Jul 19 23:28:16 media kernel: [260151.909595] xhci_hcd 0000:03:00.0: WARN: Stalled endpoint Jul 19 23:28:16 media kernel: [260151.910159] sd 11:0:0:1: [sdc] Result: hostbyte=DID_OK driverbyte=DRIVER_SENSE Jul 19 23:28:16 media kernel: [260151.910163] sd 11:0:0:1: [sdc] Sense Key : Illegal Request [current] Jul 19 23:28:16 media kernel: [260151.910167] Info fld=0x0 Jul 19 23:28:16 media kernel: [260151.910169] sd 11:0:0:1: [sdc] Add. Sense: Invalid field in cdb Jul 19 23:28:16 media kernel: [260151.910172] sd 11:0:0:1: [sdc] CDB: Read(10): 28 20 00 00 00 00 00 00 08 00 Jul 19 23:28:16 media kernel: [260151.910182] quiet_error: 2 callbacks suppressed Jul 19 23:28:16 media kernel: [260151.910570] xhci_hcd 0000:03:00.0: WARN: Stalled endpoint Jul 19 23:28:16 media kernel: [260151.911153] sd 11:0:0:1: [sdc] Result: hostbyte=DID_OK driverbyte=DRIVER_SENSE Jul 19 23:28:16 media kernel: [260151.911156] sd 11:0:0:1: [sdc] Sense Key : Illegal Request [current] Jul 19 23:28:16 media kernel: [260151.911159] Info fld=0x0 Jul 19 23:28:16 media kernel: [260151.911161] sd 11:0:0:1: [sdc] Add. Sense: Invalid field in cdb Jul 19 23:28:16 media kernel: [260151.911164] sd 11:0:0:1: [sdc] CDB: Read(10): 28 20 00 00 00 00 00 00 08 00 Jul 19 23:28:16 media kernel: [260151.911385] xhci_hcd 0000:03:00.0: WARN: Stalled endpoint Jul 19 23:28:16 media kernel: [260151.911902] sd 11:0:0:1: [sdc] Result: hostbyte=DID_OK driverbyte=DRIVER_SENSE Jul 19 23:28:16 media kernel: [260151.911905] sd 11:0:0:1: [sdc] Sense Key : Illegal Request [current] Jul 19 23:28:16 media kernel: [260151.911908] Info fld=0x0 Jul 19 23:28:16 media kernel: [260151.911910] sd 11:0:0:1: [sdc] Add. Sense: Invalid field in cdb Jul 19 23:28:16 media kernel: [260151.911913] sd 11:0:0:1: [sdc] CDB: Read(10): 28 20 00 00 00 00 00 00 08 00 Jul 19 23:28:16 media kernel: [260151.912128] xhci_hcd 0000:03:00.0: WARN: Stalled endpoint Jul 19 23:28:16 media kernel: [260151.912650] sd 11:0:0:1: [sdc] Result: hostbyte=DID_OK driverbyte=DRIVER_SENSE Jul 19 23:28:16 media kernel: [260151.912653] sd 11:0:0:1: [sdc] Sense Key : Illegal Request [current] Jul 19 23:28:16 media kernel: [260151.912656] Info fld=0x0 Jul 19 23:28:16 media kernel: [260151.912657] sd 11:0:0:1: [sdc] Add. Sense: Invalid field in cdb Jul 19 23:28:16 media kernel: [260151.912660] sd 11:0:0:1: [sdc] CDB: Read(10): 28 20 00 00 00 00 00 00 08 00 Jul 19 23:28:16 media kernel: [260151.912876] xhci_hcd 0000:03:00.0: WARN: Stalled endpoint Jul 19 23:28:16 media kernel: [260151.913439] sd 11:0:0:1: [sdc] Result: hostbyte=DID_OK driverbyte=DRIVER_SENSE Jul 19 23:28:16 media kernel: [260151.913442] sd 11:0:0:1: [sdc] Sense Key : Illegal Request [current] Jul 19 23:28:16 media kernel: [260151.913445] Info fld=0x0 Jul 19 23:28:16 media kernel: [260151.913446] sd 11:0:0:1: [sdc] Add. Sense: Invalid field in cdb Jul 19 23:28:16 media kernel: [260151.913449] sd 11:0:0:1: [sdc] CDB: Read(10): 28 20 00 00 00 00 00 00 08 00 Jul 19 23:28:16 media kernel: [260151.945227] xhci_hcd 0000:03:00.0: WARN: Stalled endpoint Jul 19 23:28:16 media kernel: [260151.945863] sd 11:0:0:1: [sdc] Result: hostbyte=DID_OK driverbyte=DRIVER_SENSE Jul 19 23:28:16 media kernel: [260151.945866] sd 11:0:0:1: [sdc] Sense Key : Illegal Request [current] Jul 19 23:28:16 media kernel: [260151.945870] Info fld=0x0 Jul 19 23:28:16 media kernel: [260151.945871] sd 11:0:0:1: [sdc] Add. Sense: Invalid field in cdb Jul 19 23:28:16 media kernel: [260151.945875] sd 11:0:0:1: [sdc] CDB: Read(10): 28 20 00 00 00 00 00 00 08 00 (...) and so on for like 10 seconds until it gives up (...) 3. Question So, my question would be: what is causing this? Am I missing something, should I configure things differently, is this a known limitation? Searching online for more information did not yield any useful results... Thank you in advance for any help!

    Read the article

  • How to diagnose failing 6Gbps SATA connection?

    - by whitequark
    I have a Samsung RC530 notebook and OCZ Vertex-3 6Gbps SATA SSD working in AHCI mode. # dmesg | grep DMI SAMSUNG ELECTRONICS CO., LTD. RC530/RC730/RC530/RC730, BIOS 03WD.M008.20110927.PSA 09/27/2011 # lspci -nn 00:1f.2 SATA controller [0106]: Intel Corporation 6 Series/C200 Series Chipset Family 6 port SATA AHCI Controller [8086:1c03] (rev 04) # sdparm -a /dev/sda /dev/sda: ATA OCZ-VERTEX3 2.15 At the boot, the following messages are present in dmesg (I am running Debian wheezy @ Linux 3.2.8): # dmesg | grep -iE '(ata|ahci)' [ 5.179783] ahci 0000:00:1f.2: version 3.0 [ 5.179802] ahci 0000:00:1f.2: PCI INT B -> GSI 19 (level, low) -> IRQ 19 [ 5.179864] ahci 0000:00:1f.2: irq 42 for MSI/MSI-X [ 5.195424] ahci 0000:00:1f.2: AHCI 0001.0300 32 slots 6 ports 6 Gbps 0x5 impl SATA mode [ 5.195429] ahci 0000:00:1f.2: flags: 64bit ncq sntf pm led clo pio slum part ems apst [ 5.195436] ahci 0000:00:1f.2: setting latency timer to 64 [ 5.204035] scsi0 : ahci [ 5.204301] scsi1 : ahci [ 5.204447] scsi2 : ahci [ 5.204592] scsi3 : ahci [ 5.204682] scsi4 : ahci [ 5.204799] scsi5 : ahci [ 5.204917] ata1: SATA max UDMA/133 abar m2048@0xf7c06000 port 0xf7c06100 irq 42 [ 5.204920] ata2: DUMMY [ 5.204923] ata3: SATA max UDMA/133 abar m2048@0xf7c06000 port 0xf7c06200 irq 42 [ 5.204924] ata4: DUMMY [ 5.204926] ata5: DUMMY [ 5.204927] ata6: DUMMY [ 5.523039] ata3: SATA link up 1.5 Gbps (SStatus 113 SControl 300) [ 5.525911] ata3.00: ATAPI: TSSTcorp CDDVDW SN-208BB, SC00, max UDMA/100 [ 5.531006] ata1: SATA link up 6.0 Gbps (SStatus 133 SControl 300) [ 5.533703] ata3.00: configured for UDMA/100 [ 5.542790] ata1.00: ATA-8: OCZ-VERTEX3, 2.15, max UDMA/133 [ 5.542800] ata1.00: 117231408 sectors, multi 16: LBA48 NCQ (depth 31/32), AA [ 5.552751] ata1.00: configured for UDMA/133 [ 5.553050] scsi 0:0:0:0: Direct-Access ATA OCZ-VERTEX3 2.15 PQ: 0 ANSI: 5 [ 5.559621] scsi 2:0:0:0: CD-ROM TSSTcorp CDDVDW SN-208BB SC00 PQ: 0 ANSI: 5 [ 5.564059] sd 0:0:0:0: [sda] 117231408 512-byte logical blocks: (60.0 GB/55.8 GiB) [ 5.564127] sd 0:0:0:0: [sda] Write Protect is off [ 5.564131] sd 0:0:0:0: [sda] Mode Sense: 00 3a 00 00 [ 5.564158] sd 0:0:0:0: [sda] Write cache: enabled, read cache: enabled, doesn't support DPO or FUA [ 5.564582] sda: sda1 [ 5.564810] sd 0:0:0:0: [sda] Attached SCSI disk [ 5.572006] sr0: scsi3-mmc drive: 16x/24x writer dvd-ram cd/rw xa/form2 cdda tray [ 5.572010] cdrom: Uniform CD-ROM driver Revision: 3.20 [ 5.572189] sr 2:0:0:0: Attached scsi CD-ROM sr0 [ 6.717181] ata1.00: exception Emask 0x50 SAct 0x1 SErr 0x280900 action 0x6 frozen [ 6.717238] ata1.00: irq_stat 0x08000000, interface fatal error [ 6.717291] ata1: SError: { UnrecovData HostInt 10B8B BadCRC } [ 6.717342] ata1.00: failed command: READ FPDMA QUEUED [ 6.717395] ata1.00: cmd 60/50:00:20:39:58/00:00:00:00:00/40 tag 0 ncq 40960 in [ 6.717396] res 40/00:00:20:39:58/00:00:00:00:00/40 Emask 0x50 (ATA bus error) [ 6.717503] ata1.00: status: { DRDY } [ 6.717553] ata1: hard resetting link [ 7.033417] ata1: SATA link up 6.0 Gbps (SStatus 133 SControl 300) [ 7.055234] ata1.00: configured for UDMA/133 [ 7.055262] ata1: EH complete [ 7.147280] ata1.00: exception Emask 0x10 SAct 0xf8 SErr 0x280100 action 0x6 frozen [ 7.147340] ata1.00: irq_stat 0x08000000, interface fatal error [ 7.147393] ata1: SError: { UnrecovData 10B8B BadCRC } [ 7.147460] ata1.00: failed command: READ FPDMA QUEUED [ 7.147529] ata1.00: cmd 60/08:18:88:17:41/00:00:02:00:00/40 tag 3 ncq 4096 in [ 7.147531] res 40/00:38:50:99:64/00:00:02:00:00/40 Emask 0x10 (ATA bus error) [ 7.147691] ata1.00: status: { DRDY } [ 7.147754] ata1.00: failed command: READ FPDMA QUEUED [ 7.147821] ata1.00: cmd 60/00:20:f8:42:4c/01:00:02:00:00/40 tag 4 ncq 131072 in [ 7.147822] res 40/00:38:50:99:64/00:00:02:00:00/40 Emask 0x10 (ATA bus error) [ 7.147977] ata1.00: status: { DRDY } [ 7.148036] ata1.00: failed command: READ FPDMA QUEUED [ 7.148100] ata1.00: cmd 60/50:28:f8:43:4c/00:00:02:00:00/40 tag 5 ncq 40960 in [ 7.148101] res 40/00:38:50:99:64/00:00:02:00:00/40 Emask 0x10 (ATA bus error) [ 7.148255] ata1.00: status: { DRDY } [ 7.148315] ata1.00: failed command: READ FPDMA QUEUED [ 7.148379] ata1.00: cmd 60/00:30:50:98:64/01:00:02:00:00/40 tag 6 ncq 131072 in [ 7.148380] res 40/00:38:50:99:64/00:00:02:00:00/40 Emask 0x10 (ATA bus error) [ 7.148534] ata1.00: status: { DRDY } [ 7.148593] ata1.00: failed command: READ FPDMA QUEUED [ 7.148657] ata1.00: cmd 60/00:38:50:99:64/01:00:02:00:00/40 tag 7 ncq 131072 in [ 7.148658] res 40/00:38:50:99:64/00:00:02:00:00/40 Emask 0x10 (ATA bus error) [ 7.148813] ata1.00: status: { DRDY } [ 7.148875] ata1: hard resetting link [ 7.464842] ata1: SATA link up 6.0 Gbps (SStatus 133 SControl 300) [ 7.486794] ata1.00: configured for UDMA/133 [ 7.486822] ata1: EH complete [ 7.546395] ata1.00: exception Emask 0x10 SAct 0x2f SErr 0x280100 action 0x6 frozen [ 7.546470] ata1.00: irq_stat 0x08000000, interface fatal error [ 7.546531] ata1: SError: { UnrecovData 10B8B BadCRC } [ 7.546588] ata1.00: failed command: READ FPDMA QUEUED [ 7.546648] ata1.00: cmd 60/00:00:e0:4b:61/01:00:02:00:00/40 tag 0 ncq 131072 in [ 7.546649] res 40/00:28:e0:4c:61/00:00:02:00:00/40 Emask 0x10 (ATA bus error) [ 7.546794] ata1.00: status: { DRDY } [ 7.546847] ata1.00: failed command: READ FPDMA QUEUED [ 7.546906] ata1.00: cmd 60/00:08:90:2f:48/01:00:02:00:00/40 tag 1 ncq 131072 in [ 7.546907] res 40/00:28:e0:4c:61/00:00:02:00:00/40 Emask 0x10 (ATA bus error) [ 7.547053] ata1.00: status: { DRDY } [ 7.547106] ata1.00: failed command: READ FPDMA QUEUED [ 7.547165] ata1.00: cmd 60/00:10:90:30:48/01:00:02:00:00/40 tag 2 ncq 131072 in [ 7.547166] res 40/00:28:e0:4c:61/00:00:02:00:00/40 Emask 0x10 (ATA bus error) [ 7.547310] ata1.00: status: { DRDY } [ 7.547363] ata1.00: failed command: READ FPDMA QUEUED [ 7.547422] ata1.00: cmd 60/00:18:50:c7:64/01:00:02:00:00/40 tag 3 ncq 131072 in [ 7.547423] res 40/00:28:e0:4c:61/00:00:02:00:00/40 Emask 0x10 (ATA bus error) [ 7.547568] ata1.00: status: { DRDY } [ 7.547621] ata1.00: failed command: READ FPDMA QUEUED [ 7.547681] ata1.00: cmd 60/00:28:e0:4c:61/01:00:02:00:00/40 tag 5 ncq 131072 in [ 7.547682] res 40/00:28:e0:4c:61/00:00:02:00:00/40 Emask 0x10 (ATA bus error) [ 7.547825] ata1.00: status: { DRDY } [ 7.547882] ata1: hard resetting link [ 7.864408] ata1: SATA link up 6.0 Gbps (SStatus 133 SControl 300) [ 7.886351] ata1.00: configured for UDMA/133 [ 7.886375] ata1: EH complete [ 7.890012] ata1: limiting SATA link speed to 3.0 Gbps [ 7.890016] ata1.00: exception Emask 0x10 SAct 0x7 SErr 0x280100 action 0x6 frozen [ 7.890093] ata1.00: irq_stat 0x08000000, interface fatal error [ 7.890152] ata1: SError: { UnrecovData 10B8B BadCRC } [ 7.890210] ata1.00: failed command: READ FPDMA QUEUED [ 7.890272] ata1.00: cmd 60/00:00:90:33:48/01:00:02:00:00/40 tag 0 ncq 131072 in [ 7.890273] res 40/00:10:e0:4f:61/00:00:02:00:00/40 Emask 0x10 (ATA bus error) [ 7.890418] ata1.00: status: { DRDY } [ 7.890472] ata1.00: failed command: READ FPDMA QUEUED [ 7.890530] ata1.00: cmd 60/00:08:90:34:48/01:00:02:00:00/40 tag 1 ncq 131072 in [ 7.890531] res 40/00:10:e0:4f:61/00:00:02:00:00/40 Emask 0x10 (ATA bus error) [ 7.890672] ata1.00: status: { DRDY } [ 7.890724] ata1.00: failed command: READ FPDMA QUEUED [ 7.890781] ata1.00: cmd 60/78:10:e0:4f:61/00:00:02:00:00/40 tag 2 ncq 61440 in [ 7.890782] res 40/00:10:e0:4f:61/00:00:02:00:00/40 Emask 0x10 (ATA bus error) [ 7.890925] ata1.00: status: { DRDY } [ 7.890981] ata1: hard resetting link [ 8.208021] ata1: SATA link up 3.0 Gbps (SStatus 123 SControl 320) [ 8.230100] ata1.00: configured for UDMA/133 [ 8.230124] ata1: EH complete Looks like the SATA interface tries to use 6Gbps link, then fails miserably and Linux fallbacks to 3Gbps. This is somewhat fine for me, as the system boots successfully each time and works under high load (cd linux-3.2.8; make -j16). I've also ran memtest86+ and it did not find any errors. What concerns me more is that Grub sometimes takes a long time to load the images and/or fails to load itself completely. The error is consistent and is probablistic: that is, each time I boot I have a certain chance to fail. Actually, I have a slight suspiction on the cause of the failure. Look at the cabling: What kind of engineer does it this way? Nah. Even 1Gbps Ethernet hardly tolerates cables bent over a small angle, and there you have 6Gbps SATA. How cound I determine and fix the cause of errors and/or switch the link to 3Gbps mode permanently?

    Read the article

  • Get HDD (and NOT Volume) Serial Number on Vista Ultimate 64 bit

    - by TheAgent
    Hi all. I was once looking for getting the HDD serial number without using WMI, and I found it. The code I found and posted on StackOverFlow.com works very well on 32 bit Windows, both XP and Vista. The trouble only begins when I try to get the serail number on 64 bit OSs (Vista Ultimate 64, specifically). The code returns String.Empty, or a Space all the time. Anyone got an idea how to fix this? EDIT: I used the tools Dave Cluderay suggested, with interesting results: Here is the output from DiskId32, on Windows XP SP2 32-bit: To get all details use "diskid32 /d" Trying to read the drive IDs using physical access with admin rights Drive 0 - Primary Controller - - Master drive Drive Model Number________________: [MAXTOR STM3160215AS] Drive Serial Number_______________: [ 6RA26XK3] Drive Controller Revision Number__: [3.AAD] Controller Buffer Size on Drive___: 2097152 bytes Drive Type________________________: Fixed Drive Size________________________: 160041885696 bytes Trying to read the drive IDs using the SCSI back door Drive 4 - Tertiary Controller - - Master drive Drive Model Number________________: [MAXTOR STM3160215AS] Drive Serial Number_______________: [ 6RA26XK3] Drive Controller Revision Number__: [3.AAD] Controller Buffer Size on Drive___: 2097152 bytes Drive Type________________________: Fixed Drive Size________________________: 160041885696 bytes Trying to read the drive IDs using physical access with zero rights **** STORAGE_DEVICE_DESCRIPTOR for drive 0 **** Vendor Id = [] Product Id = [MAXTOR STM3160215AS] Product Revision = [3.AAD] Serial Number = [] **** DISK_GEOMETRY_EX for drive 0 **** Disk is fixed DiskSize = 160041885696 Trying to read the drive IDs using Smart Drive 0 - Primary Controller - - Master drive Drive Model Number________________: [MAXTOR STM3160215AS] Drive Serial Number_______________: [ 6RA26XK3] Drive Controller Revision Number__: [3.AAD] Controller Buffer Size on Drive___: 2097152 bytes Drive Type________________________: Fixed Drive Size________________________: 160041885696 bytes Hard Drive Serial Number__________: 6RA26XK3 Hard Drive Model Number___________: MAXTOR STM3160215AS And DiskId32 run on Windows Vista Ultimate 64-bit: To get all details use "diskid32 /d" Trying to read the drive IDs using physical access with admin rights Trying to read the drive IDs using the SCSI back door Trying to read the drive IDs using physical access with zero rights **** STORAGE_DEVICE_DESCRIPTOR for drive 0 **** Vendor Id = [MAXTOR S] Product Id = [TM3160215AS] Product Revision = [3.AA] Serial Number = [] **** DISK_GEOMETRY_EX for drive 0 **** Disk is fixed DiskSize = 160041885696 Trying to read the drive IDs using Smart Hard Drive Serial Number__________: Hard Drive Model Number___________: Notice how much lesser the information is on Vista, and how the Serial Number is not returned. Also the other tool, EnumDisk, refers to my hard disks on Vista as "SCSI" as opposed to "ATA" on Windows XP. Any ideas? EDIT 2: I'm posting the results from EnumDisks: On Windows XP SP2 32-bit: Properties for Device 1 Device ID: IDE\DiskMAXTOR_STM3160215AS_____________________3.AAD___ Adapter Properties ------------------ Bus Type : ATA Max. Tr. Length: 0x20000 Max. Phy. Pages: 0xffffffff Alignment Mask : 0x1 Device Properties ----------------- Device Type : Direct Access Device (0x0) Removable Media : No Product ID : MAXTOR STM3160215AS Product Revision: 3.AAD Inquiry Data from Pass Through ------------------------------ Device Type: Direct Access Device (0x0) Vendor ID : MAXTOR S Product ID : TM3160215AS Product Rev: 3.AA Vendor Str : *** End of Device List

    Read the article

< Previous Page | 4 5 6 7 8 9 10 11 12 13 14 15  | Next Page >