Search Results

Search found 272 results on 11 pages for 'blade chassis'.

Page 9/11 | < Previous Page | 5 6 7 8 9 10 11  | Next Page >

  • Have I bricked my Sun V20z?

    - by David Mackintosh
    I have a small pile of Sun V20z computers. I was trying to update the SP and BIOS firmwares in order to bring them all up to the same standard -- mostly to get the updated (ie actually useful) SP functionality, and figured that I would just do the BIOS while I was at it. For three of the four computers, it worked perfectly. However after the BIOS update, the fourth system won't boot. I did this: batch05-mgmt $ sp get mounts Local Remote /mnt 10.16.0.8:/export/v20z batch05-mgmt $ platform set os state update-bios /mnt/sw_images/platform/firmware/bios/V1.35.3.2/bios.sp This command may take several minutes. Please be patient. Bios started Bios Flash Transmit Started Bios Flash Transmit Complete Bios Flash update Progress: 7 Bios Flash update Progress: 6 Bios Flash update Progress: 5 Bios Flash update Progress: 4 Bios Flash update Progress: 3 Bios Flash update Progress: 2 Bios Flash update Progress: 1 Bios Flash update complete batch05-mgmt $ platform set power state on This command may take several minutes. Please be patient. After an hour of waiting, it still won't start. The chassis powers on, but beyond the fans spinning up and the hardware POST of the drives, nothing appears to happen. So if I try to re-flash the BIOS (on the theory that maybe something went wrong): batch05-mgmt $ platform set os state update-bios /mnt/sw_images/platform/firmware/bios/V1.35.3.2/bios.sp This command may take several minutes. Please be patient. Bios started Error. The operation timed out. Have I bricked it?

    Read the article

  • Windows 2003 R2 x86 Mini dump fails to write to disk

    - by Randy K
    I have 3 blade servers that are Blue Screening with a 0xC2 error as far as we can tell randomly. When it started happening I found that the servers weren't set to do provide a dump because they each have 16GB RAM and a 16GB swap file divided over 4 partitions in 4GB files. I set them to provided a small dump file (64K mini dump), but the dump files aren't being written. On start up the server event log is reporting both Event ID 45 "The system could not sucessfully load the crash dump driver." and Event ID 49 "Configuring the Page file for crash dump failed. Make sure there is a page file on the boot partition and that is large enough to contain all physical memory." I understanding is the the small dump shouldn't need a swap file large enough for all physical memory, but the error seems to point to this not being the case. The issue of course is that the max swap file size is 4GB, so this seems to be impossible. Can anyone point me where to go from here?

    Read the article

  • MultiPath configuration on RHEL5 and Clariion CX-300

    - by Kamil Z
    I have problem with discovering my FC-connected CX-300 storage. Frankly speaking I'm complete novice in FibreChannel, so step by step explanation would be appreciated. My configuration consist of two IBM HS20 blades with RHEL5.4 on board and 2x Qlogic ISP2422-based 4Gb Fibre Channel HBAs on each blade. As a FC switch there are two Brocades built in BladeCenter Chassis, and finally there is EMC Clariion CX-300. CX300, and Brocade switches should be configured properly, because they were working fine with previous configuration, which main defference was RHEL3 instead RHEL5.4 Below there is my output from several usefull commands: #lspci | grep Fibre 06:01.0 FibreChannle: Qlogic Corp. ISP2422-based 4Gb Fibre Channel to PCI-X HBA (rev 02) 06:01.1 FibreChannle: Qlogic Corp. ISP2422-based 4Gb Fibre Channel to PCI-X HBA (rev 02) #lsmod | grep qla qla2xxx 1084741 0 scsi_transport_fc 37577 1 qla2xxx scsi_mod 141717 10 scsi_dh,qla2xxx,sg,scsi_transport_fc,usb_storage,libata,mptspi,mptscsih,scsi_transport_spi,sd_mod #cat /proc/scsi/scsi Attached Devices: Host: scsi0 Channel: 00 Id: 00 Lun: 00 Vendor: LSILOGIC Model: 1030 IM IM Rev: 1000 Type: Direct-Access ANSI SCSI revision: 02 Host: scsi0 Channel: 01 Id: 00 Lun: 00 Vendor: IBM-ESXS Model: ST936701LC FN Rev: B418 Type: Direct-Access ANSI SCSI revision: 04 Host: scsi0 Channel: 01 Id: 00 Lun: 00 Vendor: IBM-ESXS Model: ST936701LC FN Rev: B418 Type: Direct-Access ANSI SCSI revision: 04 I'd followed instructions from this site (editing /etc/multipath.conf), but i failed after multipath -ll - the output was empty. Do you have any suggestions about discovering FC Connected LUNs in such configuration?

    Read the article

  • How do I Install fonts on Windows Web Server 2008 R2

    - by Eric Brearley
    I would like to install Arial on to our web servers. Just need to add, this is because we generate reports server-side and make them available in a number of downloadable formats (Excel, PDF etc), hence the need to have the fonts installed on the server. I have console access to our webfarm, and from the server I've copied the .ttf files and placed them in c:\fonts folder. Then I run the following VBScript on the server. ' VBScript to install fonts on Blade Servers ' Arial font-family Set objShell = CreateObject("Shell.Application") Set objFolder = objShell.Namespace("c:\fonts") Set objFolderItem = objFolder.ParseName("arial.ttf") objFolderItem.InvokeVerb("Install") Set objShell = CreateObject("Shell.Application") Set objFolder = objShell.Namespace("c:\fonts") Set objFolderItem = objFolder.ParseName("arialbd.ttf") objFolderItem.InvokeVerb("Install") Set objShell = CreateObject("Shell.Application") Set objFolder = objShell.Namespace("c:\fonts") Set objFolderItem = objFolder.ParseName("arialbi.ttf") objFolderItem.InvokeVerb("Install") Set objShell = CreateObject("Shell.Application") Set objFolder = objShell.Namespace("c:\fonts") Set objFolderItem = objFolder.ParseName("ariali.ttf") objFolderItem.InvokeVerb("Install") Set objShell = CreateObject("Shell.Application") Set objFolder = objShell.Namespace("c:\fonts") Set objFolderItem = objFolder.ParseName("ariblk.ttf") objFolderItem.InvokeVerb("Install") msgbox "Fonts installed" I get the message box, but no font installation pop-ups like I do when I run this script on my desktop. The fonts do not get installed, they do not sure in the font selection dialogue in notepad (on the web server) and we get the asp.net exception "Font 'Arial' cannot be found.". Have also restarted the server. I have also tried copying the .ttf files to the c:\windows\fonts folder and restarting the server. What do I need to do to install fonts on Windows Web Server 2008 R2?

    Read the article

  • Is it possible to shrink the size of an HP Smart Array logical drive?

    - by ewwhite
    I know extension is quite possible using the hpacucli utility, but is there an easy way to reduce the size of an existing logical drive (not array)? The controller is a P410i in a ProLiant DL360 G6 server. I'd like to reduce logicaldrive 1 from 72GB to 40GB. => ctrl all show config detail Smart Array P410i in Slot 0 (Embedded) Bus Interface: PCI Slot: 0 Serial Number: 5001438006FD9A50 Cache Serial Number: PAAVP9VYFB8Y RAID 6 (ADG) Status: Disabled Controller Status: OK Chassis Slot: Hardware Revision: Rev C Firmware Version: 3.66 Rebuild Priority: Medium Expand Priority: Medium Surface Scan Delay: 3 secs Surface Scan Mode: Idle Queue Depth: Automatic Monitor and Performance Delay: 60 min Elevator Sort: Enabled Degraded Performance Optimization: Disabled Inconsistency Repair Policy: Disabled Wait for Cache Room: Disabled Surface Analysis Inconsistency Notification: Disabled Post Prompt Timeout: 15 secs Cache Board Present: True Cache Status: OK Accelerator Ratio: 25% Read / 75% Write Drive Write Cache: Enabled Total Cache Size: 512 MB No-Battery Write Cache: Disabled Cache Backup Power Source: Batteries Battery/Capacitor Count: 1 Battery/Capacitor Status: OK SATA NCQ Supported: True Array: A Interface Type: SAS Unused Space: 412476 MB Status: OK Logical Drive: 1 Size: 72.0 GB Fault Tolerance: RAID 1+0 Heads: 255 Sectors Per Track: 32 Cylinders: 18504 Strip Size: 256 KB Status: OK Array Accelerator: Enabled Unique Identifier: 600508B1001C132E4BBDFAA6DAD13DA3 Disk Name: /dev/cciss/c0d0 Mount Points: /boot 196 MB, / 12.0 GB, /usr 8.0 GB, /var 4.0 GB, /tmp 2.0 GB OS Status: LOCKED Logical Drive Label: AE438D6A5001438006FD9A50BE0A Mirror Group 0: physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 146 GB, OK) physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 146 GB, OK) Mirror Group 1: physicaldrive 1I:1:3 (port 1I:box 1:bay 3, SAS, 146 GB, OK) physicaldrive 1I:1:4 (port 1I:box 1:bay 4, SAS, 146 GB, OK) SEP (Vendor ID PMCSIERA, Model SRC 8x6G) 250 Device Number: 250 Firmware Version: RevC WWID: 5001438006FD9A5F Vendor ID: PMCSIERA Model: SRC 8x6G

    Read the article

  • PXE booting LACP hosts on Force10 S50N with FTOS

    - by lolwutreddit
    Hardware: S50N Firmware: FTOS 8.4.2.6 Problem: We're trying to PXE boot some servers that are connected via port-channel interfaces with LACP. Current Work-around: we PXE boot a server with a single interface (eth0), and then use a Perl script to turn up the port-channel interfaces after the server is built. Details: Is anyone doing anything similar on Force10 S50 switches with FTOS? If not, is anyone doing this on another S series, or larger chassis-based Force10? I'm wondering if Native VLAN will solve this, since ports in a port-channel cannot explicitly have a VLAN set, and they don't seem to use the tagged or untagged VLAN that the port channel is in. I will confirm this next (I think it's the only thing I haven't tried) Juniper Example: http://broken.net/openindiana/how-to-pxe-boot-systems-on-lacp-using-juniper-switches/ Cisco: there are plenty of documented ways to solve this issue on IOS and Nexus Update/Edit: since there seems to be no way to use interface or port-channel mode commands to get the individual interfaces to show up in spanning-tree (rtsp in this case), the ports should never go into a forwarding state. I'm not going to mess with it anymore unless a) someone that has experience passes it on, or b) Force10 comes up with a solution for this (I'm guessing it will only be introduced on other S platforms (S55, S60), since the S50 seems to be near EOL). I'm basing that on the fact that the Open Automation type features are only being supported on the newer switches.

    Read the article

  • Dual Xeon Server voltages are low

    - by Mindflux
    I've got a whitebox server running CentOS 5.7. It's a Dual Xeon 5620, 24GB of RAM. The mainboard is a SuperMicro X8DT6-F and the chassis is a SC825TQ-R720LPB. Dual 720W Power supplies. We had a big power outage a couple weeks back that took down everything, I don't have any pre-power outage figures for this server, and the only reason I noticed these is because when I was bringing up the servers I was checking them out with more scrutiny than usual. http://i.imgur.com/rSjiw.png (Image of voltage readings) As you can see, CPU1 DIMM is low, +3.3V is high, 3.3VSB is high, +5v is high, +12v is REAL LOW (out of normal 5% (plus/minus))... and VBAT is off the charts. With my whitebox VAR we've tried the following: Swap out PSU with another server I have with the same PSUs. Try different power cord Update BMC/IPMI firmware in case readings were wrong (They aren't) Update BIOS Try different PDU Try a different outlet and/or circuit Replaced Voltage Regulator Unit At this point, the only thing we haven't done, seemingly is replace the mainboard.. which is what the next step will be unless something else shines some light on the situation. I should mention the system is rock solid otherwise which is a surprise given the 12v voltage is that far off.

    Read the article

  • Laptops with easy heat sink service?

    - by Niten
    Can you recommend a current laptop model with easy heat sink access – or better yet, a removable air intake filter – making it easy to periodically clean out the dust and lint that always packs up in these things? Every laptop I've owned has eventually overheated on account of a clogged heat sink. (I suppose it doesn't help that I have a cat who loves to hang out where I'm working, or that my laptop is almost always running.) One of the things I really love about my current system, a Dell Inspiron 1420n, is how easy it is to service its cooling system: whenever I notice the fan starting to work harder and the CPU temperature climbing higher than it should be, I merely have to unscrew a single panel from the bottom of the machine, clean out the heat sink, and then I'm good for another few months. Which current models of the "business laptop" variety offer similar easy cooling system service? I'm looking for something roughly along the lines of: 14- or 15-inch display Nehalem-based CPU Solid construction – magnesium chassis or better (like the Inspiron) TPM (for BitLocker) ideal, but not mandatory Docking adapter ideal, but not mandatory Good battery life For example, the ThinkPad T410 would have been my top choice, but it seems like it would be a serious chore to service its heat sink. For the current MacBook Pros it looks downright impossible. No matter how nice the laptop is in other respects, it'll be of no use to me when it's overheating. So, any suggestions? Thanks in advance... (I'm constantly surprised that customers and manufacturers don't pay more attention to this feature, at least in the business laptop subcategory. In the last couple months I've fixed two friends' laptops which were also overheating due to clogged cooling systems; clearly I'm not the only one affected by this.)

    Read the article

  • IDE/PATA high-speed hard drive dock

    - by wfaulk
    I frequently need to access bare drives for backups and need a quick, high-speed way to deal with them. There are a multitude of SATA hard drive docks (for example), but I have a lot of IDE/PATA (hereafter "IDE") drives that I would like to be able to use similarly. There are IDE-to-SATA adapters so you can plug your IDE hard drive into a SATA port, so I don't see any reason why you couldn't use the same technology to have a native dock, yet none seems to exist. Now, I'm aware that 3.5" IDE drives do not have a specification for the layout of the connector, and therefore can't be slapped into a dock the same way a SATA drive could, but 2.5" PATA drives do. In fact, I'm not terribly interested in supporting 3.5" drives. It would be nice, but I deal with them far less frequently than 2.5" drives. Also, I'd very much like for the connection to the computer be faster than USB, preferably eSATA, I don't want to be spending time mounting a drive inside an enclosure, I don't want bare drives lying around with a cable hanging off of them, and I'd prefer a single dock rather than two. What seems like the ideal solution to me would be a regular SATA→eSATA dock and some sort of screwless adapter for IDE drives, but I'm open to any suggestions, regardless of my stated preferences, but which are, in some sort of order of preference: high-speed (faster than USB, at least) holder for drive (not just a cable) no complicated enclosure support for 3.5" IDE drives single dock Updates: Here's a 3.5" IDE to 3.5" SATA docking adapter that could be part of the solution. Weird. I figured that would be the impossible part. I was hoping to find something like this 2.5" to 3.5" SATA chassis that would take a 44-pin IDE drive internally. It looks like the Vantec EZ Swap EX comes awfully close. It has its own bay dock, but it looks like the SATA ports on the back are spaced properly, even if they're not aligned quite properly. Unfortunately, the proper position is at the very edge of the drive, which means that the docks' connectors are at the very edge of their recesses, which means there's no way to fit it in there.

    Read the article

  • does my machine configuration make sense?

    - by user1227914
    i couldn't think of a better place to ask this question, so here it goes. we're putting together a dedicated server for a website that will initially host the web server and the mysql database. as the website grows, we'll move the database to a different server and this machine will eventually only server the actual website. so the question is ...does my configuration look okay? it's the first time i'm building a server from scratch so i want to make sure i don't combine components that don't fit or something. things like ..do the drives i picked work for the hot swap ..etc. what do you guys think? am i good to go with this configuration? :) Chassis: Supermicro SuperServer 6016T-MTHF (6x DDR3 SDRAM - ECC DIMM 240-pin, 2x LGA1366 Socket, Power Provided: 600 Watt, 4 (free) x hot-swap - 3.5") CPU: Intel BX80614E5620 Xeon E5620 Processor - 4 Core, 2.40GHz, LGA 1366, 5.86GT/s QPI 12MB Cache, 64-Bit, 80W, HyperThreading Memory: Crucial CT51272BB1339 4GB PC10600 DDR3 Memory - 1333MHz, ECC, Registered, 1x4096MB (possibly 3 or 4 of them) Hard Drives: Western Digital WD2002FAEX Caviar Black Hard Drive - 2TB, 3.5", SATA 6Gbps, 7200 RPM, 64MB (possibly 2 or 3). thank you very much for any professional advice :)

    Read the article

  • Fast Ethernet module for Cisco 2620

    - by Kenny Rasschaert
    I have a Cisco 2620 Router. It comes with one fast ethernet port built in (circled in red), and one old AUI ethernet module is installed (circled in blue). I figure I can put a transceiver on the AUI interface to get a second RJ45 connector. What I'd really like to have is a second fast ethernet connector. The ideal candidate to achieve this would be the NM-1FE-TX module. Cisco claims on their website that this module is not suitable for the Cisco 2620 and Cisco 2620XM. It says so in "Table 2 Physical Limitation of Serial Modules per Chassis". Indeed, this module was designed for the 3600 series of routers. I've seen claims on the internet, however, of people having this module on a 2620XM, and it being fully functional. This claim gains some credibility because of the fact that in Cisco's own Packet Tracer software, you can install this module on the 2620XM router. I'm looking for a definitive answer. Will this module work on a Cisco 2620? Is there perhaps another way to get a second fast ethernet port on this device?

    Read the article

  • Struggling to set-up NLB cluster

    - by Chris W
    I'm trying to set up NLB on a couple of Windows 2008 R2 virtual servers running on top of Hyper V R2. The servers each have a single vNIC for LAN access (and a second vNIC for SAN access). I'm setting up the cluster to use Multicast mode. The vNICs are each set to allow MAC spoofing. Essentially I'm finding that i can add SERVER1 as a host and it will pick up and respond to the cluster IP from a remote subnet. If I then 'stop' the node in NLB manager it still responds when I would expect it to stop answering on that IP. If I recreate the cluster and add SERVER2 as the first host, the wizard completes correctly and an IPCONFIG on the server shows that it now has the cluster IP but I can't ping the cluster IP from a remote subnet but I can from another machine on the same subnet. As a final test - with both servers in the cluster, pinging from another machine on the same subnet I still get a response from the cluster IP when both nodes are stopped according to the NLB manager. The two VMs are sat on the same physical blade and are built up exactly the same as they'll be used as SharePoint web front end servers. I'm at a loss as to what could be wrong with the second VM that prevents it taking on the address just as the sole node in the cluster, never mind the strange behaviour of the cluster when I stop/start nodes.

    Read the article

  • How do I make ESXi 5.0 to shutdown virtual machines when the physical power button is pushed?

    - by Pawel Sawicki
    I have a home NAS/DLNA server built out of an HP Micro Server with the HP branded VMware ESXi 5.0.0 build-623860 (free license) installed. Being a home media center I'd like it to be "manageable" by all my household members. This requires that it needs to be powered on an off (including all the VMs inside) by anybody with the physical access to the server by simply pressing the power button on the chassis. The "startup" part is easy to obtain - all I had to do was to configure the startup/shutdown policy: Once the server powers up, all VMs start as well and that's exactly what I need. Well.. it did work up until 5.0.0U1, but that's a different story: http://blogs.vmware.com/vsphere/2012/03/free-esxi-hypervisor-auto-start-breaks-with-50-update-1.html Unfortunately, pressing the power button doesn't gracefully shutdown the guest machines - they are terminated instead. If I run the "shut down" command from the vSphere Client interface guests are powered off. I'd like to get the same end result when the physical power button is switched. I've poked around a bit on the ESXi server. There's a "/sbin/shutdown.sh" script that seemed to do exactly what I need... but after trying it does exactly what the power off button. The "/etc/inittab" contains an entry for the "shutdown" level but I suppose it's not hooked to the power button. I can't find any acpi related configuration, neither do I know what exactly is executed when the power button is pressed. Does anybody have a clue how can I make the VMs shutdown automatically when the physical power switch is pressed to turn of the computer?

    Read the article

  • How to get multipath working for Ubuntu Server 12.04

    - by mlampi
    I'm working on a project which aims to make use of Ubuntu servers running on enterprise class hardware. In our case that means IBM HS23E blade servers, QLogic 4GB fibre channel extension cards and quite old IBM DS4500 disk array with two controllers. At the moment we have fibre channel as only boot option and Ubuntu Server 12.04 installed just fine and is able to boot without multipath. I'm not a linux professional myself but in our team we have people who will understand the technical stuff. Don't let my post confuse :) The current situation is that we have only one fibre channel connection to a single disk array controller. Real life case would be of course quite different. At minimum we should have two fibre channel ports connected to two different switches and two different controllers. However, we have no idea how to set up multipath tool. Is the DM-MPIO the right software? At minimum we should be able to boot when multiple connections are available and achieve fault tolerance when any of them should be down. Since the disk array is not the latest hardware, I managed to find RDAC driver sources only for 2.6.x kernel. And we have 3.2.x. Another issue is to build a multipath.conf. The said driver sources are from IBM support and the QLogic drivers provided to Ubuntu installer are from Ubuntu site. It seems that RHEL and SLES would have near out of the box support but that is not an option for our project. Actual questions: - What is the recommended software tool for multipath for Ubuntu Server 12.04? - Is there available pre-made configurations or templates? Does it require disk array / controller specific settings or do a more generic config work? - Do you have expriences on similar setup and like to share the knowledge? I'll provide you with any additional information you might require. Thanks in advance.

    Read the article

  • Is there any free software to check for issues with a DVD drive?

    - by AgentConundrum
    I don't usually play movies on my laptop (prefer the standalone with the tv), but I tried to watch one the other night, and noticed playback was really choppy and had audio artifacts in places. I thought it could be related to memory issues so I rebooted and tried again, but the results were the same. I considered that it could be an issue with the disc, so I tried to clean it but again there was no change. I don't think the problem is with the disc, because I tried another disc and it also had the same problem. I don't think I've ever watched the second disc since I've had it, so it should have been safe in its jewel case. Also, there were no issues when I watched an episode off the first disc in my standalone player. What I'm wondering is: are there are any (free) utilities that can check for issues with the drive itself? I looked around but most of the software I found focuses on integrity checks for the disc, not the drive. I have had issues with this laptop recently (had to replace the keyboard when the cat damaged it while I was cleaning dust out and the machine was ripped apart, also replaced part of the chassis after I cracked it when I tried to open it not knowing a screw was still in it) so I may have just replaced the drive incorrectly. I'm going to check on this while I await an answer to this question. Thanks.

    Read the article

  • How do I remove a USB drive's write protection?

    - by nate
    I have a SanDisk Cruser Blade USB stick that suddenly seems to be write protected. I tried running DiskPart but after I write the command "attributes disk clear readonly" it displays this: Microsoft DiskPart version 5.1.3565 ADD - Add a mirror to a simple volume. ACTIVE - Marks the current basic partition as an active boot partition. ASSIGN - Assign a drive letter or mount point to the selected volume. BREAK - Break a mirror set. CLEAN - Clear the configuration information, or all information, off the disk. CONVERT - Converts between different disk formats. CREATE - Create a volume or partition. DELETE - Delete an object. DETAIL - Provide details about an object. EXIT - Exit DiskPart EXTEND - Extend a volume. HELP - Prints a list of commands. IMPORT - Imports a disk group. LIST - Prints out a list of objects. INACTIVE - Marks the current basic partition as an inactive partition. ONLINE - Online a disk that is currently marked as offline. REM - Does nothing. Used to comment scripts. REMOVE - Remove a drive letter or mount point assignment. REPAIR - Repair a RAID-5 volume. RESCAN - Rescan the computer looking for disks and volumes. RETAIN - Place a retainer partition under a simple volume. SELECT - Move the focus to an object. It's like when you type help at the DiskPart prompt, so how do I get past this? This problem started when I plugged the stick into a laptop which had viruses, if that's any help.

    Read the article

  • Virtual Fileserver

    - by Sergei
    Hi, We are planning to move our production servers to the datacenter and virtualize remaining servers in the process.Datacenter will have HP blades with vSphere on top.Currentliy we are using Celerra NS20 as fileserver.Since datacenter is using HP kit and EVA 4400 as SAN, we cannot have Celerra there, as EMC supoprt for Celerra does not work for non EMC array. I have searched for possible options and one of them was to have HP NAS blade X3800sb instead of Celerra.However this seems like overkill for me.We are only using Celerra for about 100 users and 50 servers and I think having X3800sb could be waste of resources. The other option would be to have a virtual fileserver as a part of vmware environment in datacenter.We only need CIFS to be provided.The only option I can think of is Windows Storage server.We had a bad expirience with Windows servers used as fileservers ( memory leaks one thing) in the past and this was one of the reasons we moved to Celerra. What are the other options?We need something as reliable as Celerra with as many options as possible.For example , Celerra has per folder quotas, deduplication, dynamic volume allocation, automatic failover, VTLU, replication. Also we would need to replicate NAS data to the failover site.We could use block level replication , SAN-to-SAN, but this would mean wasted bandwidth, as we need only subset of folders to be replicated.We used CA XSoft for windows servers in the past and Celerra has option for Celerra replication. Thank you very much in advance, Please ask me if I missed any details!

    Read the article

  • My New Dell Workstation T-7500 gives electric shock

    - by Dan
    Just bought Dell T-7500 Workstation. When installation technician came to Install the workstation, he got an electric shock when he touched the Start Button. He also got shock when he touched Front Panel. No shock when touching rest of the Chassis. He called Dell Support & tried to troubleshoot by taking out various wires etc but did not help. I touched the same places & I also got shock. We checked everything possible including connecting to various outlets but it didn't solve the problem. Installation subcontractor said that they are not supposed to troubleshoot anything on new system, just install it & they made notes & left. I called my sales guy & it was weekend so he said he will take care of it on Monday. Here are my concerns : (1) Why does that happen ? Although it is a mild shock & it won't kill you but might damage other parts of workstation ? (2) Is this common for workstations ? (3) What should I do ? Of course Dell will try to troubleshoot again but should I let them do that OR ask for a New System ? (4) Wheat would happen if I continue using it till the new system arrives ? Thank You.

    Read the article

  • Best way to execute a command after Linux system halt

    - by Lukas Loesche
    Problem: The SSDs in our servers require a power cycle (i.e. off/on, not reset/warm reboot) after a firmware update. Thoughts: Using 'ipmitool chassis power cycle' I can cycle the server's power. However this would cut the power while the system is still running, filesystems are mounted, etc. What I basically want is a delayed power cycle so the system has a change to halt. But I guess that would have to be implemented on the server's IPMI board, so it's not really an option. My initial idea was to dynamically create a ramdisk containing the tool and libs and somehow integrate that into the halt process. I saw there's a /etc/init.d/halt, so that would be my starting point. Although I believe the kernel at some point in the shutdown process starts to kill off remaining processes. So I'm not even sure if that's a viable way. Question: What would be the best way to execute ipmitool (or any other command), after the system has halted and all regular filesystems are unmounted?

    Read the article

  • Small TCP Window on WAN between 2 Locations

    - by Brent
    Site A: Denver datacenter. 60MBPS. Site B: Chicago. 100MBPS. ICMP pings: Packets: Sent = 176, Received = 176, Lost = 0 (0% loss), Approximate round trip times in milli-seconds: Minimum = 74ms, Maximum = 94ms, Average = 75ms File transfer between sites that never goes past ~7MBPS: Windows Update download at 60MBPS+: Site to site: IPSec VPN using two Cisco 5520's. CPU at 3-4% and lots of memory to spare. The latency between to two sites is very acceptable so I can't see an issue why it is performing so slow when transferring between the two sites. I have found that any type of transfer (FTP, HTTP, Windows file shares) will never go above ~7MBPS. When the WAN was first setup, I was able to get transfers at 50-60MBPS, which is what is expected due to the WAN connection at the Site A at 60MBPS. Then a few days later, I was not able to get anything going faster than ~7MBPS. Is there a upstream router between Denver and Chicago causing this? I want to take the blame away from our setup as downloads from Windows Update go blazing fast and for the first few days after the site to site VPN came up, I was transferring VM images at 50-60MBPS. Our stack: HP P2000 MSA - HP C7000 Chassis - HP Flex-10 - Cisco Gigabit switch - Cisco ASA - WAN

    Read the article

  • SQL Server architecture - they want to move my database to new instance...Why?

    - by O'MALLEY
    Our current production database environment contains about 10 similarily managed databases. Our agency has just purchased and is installing new blade chasses and wants to move my database to a new instance (leaving the other 9 on another). This decision is being driven by one of our IT staff, not a DBA. I am a project manager, not a DBA but I know enough to not necesarrily have a good feeling about this decision and I am urging our IT department to make a sound decision based on what is best for the database. Our IT department has stated that it is not good to have all our eggs in one basket, and has also stated that my database contains "regulatory data" so it should be on its own instance. A couple of truths: - None of the databases on the current instance are OLTP databases nor are any of them data warehouses - My database currently has joins/views to a couple of the other databases in the production environment So my questions are as follows: Am I wrong to disregard a statement about eggs in baskets? (hello, this is why we have maintenance plans/disaster recovery plans). I'll mention that other databases also have regulatory data too. What types of questions do I need to ask to determine if this is a sound decicion? (A DBA friend mentioned that if the service level agreement of said database does not radically differ from the others then why do they want to do this?) I have done some research on linked servers. What arguments should I bring forth about the fact that I have views setup that rely on data from other DBs currently?

    Read the article

  • Cisco Access switch is dropping large amount of end points

    - by user135458
    This afternoon, with no changes to the network, a switch suddenly started dropping off lots of connections. These connections would come back up a few minutes later, then another area connected to the switch would drop off. This is an older 4006 chassis switch which could in and of itself be a problem but I'm looking to see what else you all would look for in trying to find a root cause. Switch is connected via ports 1/1 and 1/2 in an etherchannel to a VSS core 1/1/42 and 2/1/42. Both sides are up and working however the CPU on the switch will spike up to 99% and that's when CRC errors start to hit the VSS core on one of those interfaces and end points start dropping off. We tried new transceivers and SFP's on each side of the link, same result. When we tried swapping the fiber patch cables on the access switch the CRC errors did not follow the fiber cables they stayed with port 1/2 on the access switch. So port 1/2 on the supervisor module looks like the culprit. We actually tried to create a new member of the ethernet channel by taking a fiber media converter to cat5 and make that a member of the port-channel but when we plugged it in you couldn't even reach the switch. I'm guessing that's unrelated and a problem with the media converter. As of right now we have left it in a state of only one fiber cable running to one side of the VSS core (1/1 Access Switch -- 2/1/42). I've sent some info into TAC and they are looking into the situation but does anyone else have any commands I could run or some troubleshooting I could look into in the meantime?

    Read the article

  • Upgrade SQLServer 2008 hardware

    - by John
    Forgive me if I'm not able to be totally clear here. It is not intentional, I'm a senior level developer in a very small company having to act like a manager at the moment. Anyway, the story is that we have 2 older dell servers with SQL Server 2008 Standard in a "cluster". I put that in quotes because I'm still not 100% clear what that means. We have 2 brand new blade servers and want to move the existing databases to the new hardware. Ok, so here is the gotcha. We need to do this with little or no down time. I'm being told that we can evict the passive node, then pull in one of the new servers. But I'm also being told that this is a dangerous step because something could go wrong that would cause the cluster to fail and then we would be left with nothing because the active server would not be able to come back up. Does anyone have any thoughts on how to handle this? I'm being told that the only way to ensure success is to have at least a day of down time where we bring up a new cluster on the new hardware and then migrate the databases 1 by 1.

    Read the article

  • Exceptional slowdown of robocopy copying from VM to DFS array

    - by user1588867
    I've got an old win 2003 VM (VMware) on a blade cluster of VMs that I'm moving a considerable amount of files to our new DFS array. There are two main folders with about 1.7 million and half a million smaller files (letters, memos, and other smaller files) respectively. Total size is ~420 GB and ~100 GB. We're using the gui version of robocopy on the server to copy the files. We had initiated a file copy about a month ago to test the process and found that it was taking around 4 hours for the large file. Now that I'm in the process of actually switching the files over it has been taking 18-20 hours. Nothing has changed on the server side and nothing has changed on the settings of the copy (no logs, 1 retry with a wait of 1 second). Our intent is to shut off the share and force the copy over again to get all the files that have been left out of the copy due to being locked by users. I can't take a 20 hour outage to do that though. Does anyone have any theories about what could be causing such a delay for robocopy compared to previously shorter runs?

    Read the article

  • What are my options in replacing the noisy fan in my Linksys Cisco SRW2008P managed GigE switch?

    - by Fred Sobotka
    My first managed GigE switch, the Linksys SRW2008, was a dream, until it started randomly chattering on various ports. That started while I was on the road all the time, which made it take forever to diagnose, but that's a different problem. When I finally determined that the switch was bad, it was still covered by warranty by Linksys/Cisco, so I opened an RMA ticket and returned it. Unfortunately, Linksys/Cisco "upgraded" my replacement switch to a SRW2008P, which has Power over Ethernet features I never planned on using. That by itself wasn't so bad, but it's my guess that the inclusion of PoE functions in this model required a tiny, super-loud internal fan to keep everything cool. This wasn't something I wanted or asked for, but, now that I am stuck with it, I am investigating options for replacing that little internal fan with something far quieter. For example, if I attach a larger fan to the outsite of the chassis, I think it could push enough air to replace the stock fan that is currently there. Any advice on carrying this out? I have no interest in melting my switch due to insufficient ventilation.

    Read the article

< Previous Page | 5 6 7 8 9 10 11  | Next Page >