Search Results

Search found 272 results on 11 pages for 'blade chassis'.

Page 5/11 | < Previous Page | 1 2 3 4 5 6 7 8 9 10 11  | Next Page >

  • Openmatics Revolutionizes Fleet Management with Standards-Based Vehicle Telematics Platform

    - by Michael Snow
    Openmatics s.r.o. was founded in 2010 as a subsidiary of ZF Friedrichshafen AG, a global player in driveline and chassis technology. Oracle Customer:  Openmatics s.r.o.Location:  Pilsen, Czech RepublicIndustry:  AutomotiveEmployees:  70 Its goal was to develop and operate a flexible, open telematics platform for automotive applications, which is independent from vehicle and component suppliers—recognizing that the fragmented telematics market was not meeting today’s fleet management needs. Openmatics provides a rich product portfolio, and customers can extend the platform, as required, to meet their needs. Partners and third-parties can develop their own applications using the Openmatics’ software development kit and can sell them via the Openmatics app shop.ZF Friedrichshafen AG is a global player in driveline and chassis technology. With 121 production companies and 650 service partners in 26 countries, ZF is among the top 10 largest automotive suppliers worldwide. Founded in 1915 to develop and produce transmissions for airships and vehicles, the group’s product offerings now include transmissions and steering systems as well as chassis components and complete axle systems and modules.  A word from Openmatics s.r.o.  “Oracle WebCenter Portal, together with the underlying Oracle Application Development Framework, provided the fundamental infrastructure for the Openmatics platform. Fleet managers can now reduce fuel consumption and operating costs, and more efficiently manage vehicle usage, maintenance, and safety. The standards-based platform allows third-party suppliers to deploy their own vehicle telematics services as Openmatics apps and creates a de facto standard for the automotive industry, independent from a single manufacturer or service provider.” – Gero Strobel, Head of Development, Openmatics s.r.o. Challenges Create an industry standard for vehicle telematics by establishing a customizable platform that enables access to telematics information, such as current and past fuel consumption, through a web browser to better meet automotive market and customer needs Reduce fleet-management costs by eliminating the need to invest in isolated telematics hardware and software solutions per vehicle brand and vehicle component manufacturer Establish an open platform where third-party providers—such as original equipment manufacturers (OEM), insurers, fleet operators, and individual developers—can deploy their own vehicle telematics services Allow users to purchase targeted telematics services as single apps to reduce costs and ensure rapid growth of telematics services available on the platform Enable users to configure their telematics apps with ease to make sure the platform meets individual fleet management requirements, such as analyzing past and current fuel consumption of a truck fleet Solutions Deployed Oracle WebCenter Portal as a foundation for Openmatics, a standards-based automotive telematics platform that provides next-generation fleet management with unified digital communication from and to vehicles on the move Used Oracle Application Development Framework as the development framework for Oracle WebCenter Portal’s components and services, providing developers with ready-to-use software development kits with application programming interfaces, design templates, and visual tools that accelerated time to market Used Oracle Enterprise Pack for Eclipse to simplify telematics application development in Java Enabled fleet monitoring by recording vehicle data—such as fuel consumption information—through onboard units, delivering the information to Oracle Database, and making it accessible through a customizable app portfolio on any web browser Stored vehicle telematics data—sent as encrypted information—in Oracle Database, ensuring data integrity and immediate availability for the platform’s telematics applications Enabled a wide range of telematics services suppliers, from vehicle component manufacturers to fleet application developers, to offer vehicle telematics services on the Openmatics platform, ensuring platform independence from OEMs Provided Openmatics customers with the means to individually select the automotive telematics services that are relevant to their business requirements, eliminating the need to pay for superfluous information and reducing fleet management costs Oracle Products & Services Oracle Application Development Framework Oracle WebCenter Portal Oracle SOA Suite Oracle Enterprise Pack for Eclipse Oracle Database Oracle Consulting &amp;amp;amp;amp;amp;amp;amp;&amp;amp;amp;amp;amp;lt;span id=&amp;amp;amp;amp;amp;quot;XinhaEditingPostion&amp;amp;amp;amp;amp;quot;&amp;amp;amp;amp;amp;gt;&amp;amp;amp;amp;amp;lt;/span&amp;amp;amp;amp;amp;gt;amp;&amp;amp;amp;amp;amp;amp;lt;span id=&amp;amp;amp;amp;amp;amp;quot;XinhaEditingPostion&amp;amp;amp;amp;amp;amp;quot;&amp;amp;amp;amp;amp;amp;gt;&amp;amp;amp;amp;amp;amp;lt;/span&amp;amp;amp;amp;amp;amp;gt;lt;p&amp;amp;amp;amp;amp;amp;amp;amp;gt; &amp;amp;amp;amp;amp;amp;amp;amp;lt;/p&amp;amp;amp;amp;amp;amp;amp;amp;gt;

    Read the article

  • NIC light is turned off after boot on Redhat 4.6 server

    - by hoffmandirt
    I have a 2950 blade server setup with Red Hat 4.6 installed. I cannot get the NIC to work properly after reinstalling Linux. I activated the NIC, but the NIC light will not turn on when I plug the network cable into the hub. The status light on the hub will not turn on either. If I run ifconfig, the NIC status is UP. Also I can ping the IP address that I assign to the Linux machine, but I can't ping anything else that is plugged into the hub. When I reboot the system, the NIC light will stay on until the system fully boots and then it will turn off again. Is there something else that I need to do to get the NIC working? It appears to be disabled even though ifconfig says that it is UP. Maybe I need to configure something within the blade server (iDRAC)?

    Read the article

  • Hyper V cluster - one VM won't migrate

    - by Chris W
    We have a Failover Cluster built up on 6 blades, each running Hyper V. Each box is running Server 2008 R2. We've got a number of VMs running that all have the same basic config: VHD stored on a cluster shared volume. 2 virtual NICs (1 for LAN connection and 1 for SAN connection). All of our VMs will happily migrate between any other blade apart from one single VM which is running fine on it's current blade but will not migrate to any other location. What could be the cause of it or where should I look to get a detailed error message as I can't seem to find much information logged in any of the logs. Edit: I know the usual culprit is mis-matching resource names. We've already been there with the NICs named differently on some of the blades. As far as we can tell now everything looks to be identical on each bit of metal.

    Read the article

  • How many websites can my server potentially hold?

    - by Daniel Kindler
    Sorry for the "noob" question, but... About how many medium-sized websites with average traffic could this server hold? Just like the average website, kind of like a small business site. How many sites could this server hold, but still maintain nice, decent speed? PowerEdge R510 PE R510 Chassis for Up to Four 3.5" Cabled Hard Drives, LED edit Processor Intel® Xeon® E5630 2.53Ghz, 12M Cache,Turbo, HT, 1066MHz Max Mem edit Memory 8GB Memory (4x2GB), 1333MHz Single Ranked UDIMMs for 1 Procs, Optimized edit Operating System SUSE Linux Enterprise Server 10, SP3, Up To 32 CPU Lic, 1 YR Sub, DIB, Media edit Red Hat Enterprise Linux Licensing Hard Drives 250GB 7.2K RPM SATA 3.5" Cabled Hard Drive edit Hard Drives 1TB 7.2K RPM SATA 3.5" Cabled Hard Drive edit Hard Drives 2 X 2TB 7.2K RPM SATA 3.5in Cabled Hard Drive Hard Drive Configuration No RAID, Embedded SATA Controller for x4 Chassis edit Power Supply 480 Watt Non-Redundant Power Supply edit Thank you!

    Read the article

  • I know this is a stupid question but... How many websites can my server potentially hold?

    - by Daniel Kindler
    Sorry for the "noob" question, but... About how many medium-sized websites with average traffic could this server hold? Just like the average website, kind of like a small business site. How many sites could this server hold, but still maintain nice, decent speed? PowerEdge R510 PE R510 Chassis for Up to Four 3.5" Cabled Hard Drives, LED edit Processor Intel® Xeon® E5630 2.53Ghz, 12M Cache,Turbo, HT, 1066MHz Max Mem edit Memory 8GB Memory (4x2GB), 1333MHz Single Ranked UDIMMs for 1 Procs, Optimized edit Operating System SUSE Linux Enterprise Server 10, SP3, Up To 32 CPU Lic, 1 YR Sub, DIB, Media edit Red Hat Enterprise Linux Licensing Hard Drives 250GB 7.2K RPM SATA 3.5" Cabled Hard Drive edit Hard Drives 1TB 7.2K RPM SATA 3.5" Cabled Hard Drive edit Hard Drives 2 X 2TB 7.2K RPM SATA 3.5in Cabled Hard Drive Hard Drive Configuration No RAID, Embedded SATA Controller for x4 Chassis edit Power Supply 480 Watt Non-Redundant Power Supply edit Thank you!

    Read the article

  • links for 2010-12-15

    - by Bob Rhubart
    Pravin Janardanam: Security in OBIEE 11g, Part 1 Guest blogger Pravin Janardanam kicks off a two-part series in which he tackles the differences in security between OBIEE 11g and 10g, and provides some hints on security migration from a 10g environment. (tags: oracle otn businessintelligence obiee) HttpClusterServlet Configuration (Weblogic Server Acting as a Proxy) Quick tips from Divay Dureja. (tags: oracle weblogic servlet configuration) Accelerating Deployment of Virtualized Infrastructures with the Oracle VM Blade Cluster Reference Configuration "The Oracle VM blade cluster reference configuration is a single-vendor solution that addresses every layer of the virtualization stack with Oracle hardware and software components." - from the white paper. (tags: oracle otn oraclevm virtualization) A SOA Safari (Antony Reynolds' Blog) SOA author Antony Reynolds shares links to some of his favorite SOA titles available for reading on Safari. (tags: oracle otn soa) Using Crossbow and Solaris 11 Express Zones for a single machine proof of concept environment with Puppet "My last blog entry was about my debugging experience with Puppet and promise to share the setup that I used. I now follow up that previous entry with this one which describes my Crossbow + NAT + S11 Zones proof of concept." - Michael Tin (tags: oracle solaris crossbow) @myfear: One thing you did not know about Java EE class loading in GlassFish 2.x "Be careful migrating apps from one app server to the other. And don't expect to have a strong hierarchical class loader in place. That is especially true for GF 2.x class loading." Oracle ACE Director Markus Eisele (tags: oracle otn oracleace java glassfish weblogic)

    Read the article

  • Gateway ZA8 Netbook graphics Issue

    - by Hansel
    The graphics keep tearing and are barely usable anytime I try to use my Netbook. And I did a full install with Ubuntu so I'm pretty much stuck. These are the specs of the Netbook: Processor AMD Athlon™ 64 L110 Single-Core Processor (1.2GHz, 800MHz FSB, 512KB L2 Cache)6 Operating System Genuine Windows Vista® Home Basic (32-bit) with SP1 Display 11.6" HD WXGA Ultrabright™ LED-backlit Display (1366 x 768 resolution, 16:9 aspect ratio)7 Memory 2048MB DDR2 533MHz SDRAM Single Channel Memory8 Hard Drive 250GB SATA hard drive2 Color Classic and Elegant Design with Cherry Red finish Wireless Network 802.11b/g Wi-Fi CERTIFIED®3 Adapter AC Adapter Application Software Microsoft® Works, Microsoft® Money Essentials, Microsoft® Office Home and Student 2007 (60-day complimentary trial period)1 Battery 6-Cell Lithium Ion (5200mAh) Chassis Chassis with ATI Radeon® X1270 Graphics and AMD RS690E Chipset8 Dimensions (Box) 3.1" (H) x 14.8" (W) x 10.1" (D) or 80mm (H) x 376mm (W) x 256mm (D) Dimensions (System) 1.03" (H) x 11.26" (W) x 7.99" (D) or 26.4mm (H) x 286mm (W) x 203mm (D) External Ports (3) USB 2.0, VGA Connector Keyboard and Mouse Keyboard with Multi-Gesture Touchpad Media Card Reader Multi-in-1 Digital Media Card Reader (Memory Stick®, Memory Stick Pro™, MultiMediaCard, Secure Digital™, xD-Picture Card™) Network 10/100 Ethernet LAN (RJ-45 port) What can I do?

    Read the article

  • postgresql count

    - by dars
    Can this be done in PGSQL? I have a view which I created where hostname,ip, and datacenter are from one table, and ifdesc and if stats from another table. the view output looks like this: hostname | ip | datacenter | ifdesc | ifadminstat | ifoperstat| ---------- ------------------------------------------------------------------ r1 1.1.1.1 dc GigabitEthernet1/1 2 1 r1 1.1.1.1 dc GigabitEthernet1/2 2 2 r1 1.1.1.1 dc GigabitEthernet1/3 2 2 r1 1.1.1.1 dc GigabitEthernet1/4 2 1 r1 1.1.1.1 dc GigabitEthernet2/1 2 2 r1 1.1.1.1 dc GigabitEthernet2/2 2 2 r2 2.2.2.2 dc GigabitEthernet1/1 2 2 r2 2.2.2.2 dc GigabitEthernet1/2 2 2 I need to get a count of "ifadminstat = 2" and "ifoperstat = 2" for all interfaces on each blade, for each router (for example... for r1, how many interfaces on blade 1 (GigabitEthernet1/1-48) have "ifadminstat = 2" and "ifoperstat = 2". I am trying to do the counting in Postgresql then present the results on a website using PHP.

    Read the article

  • Determining the required depth and specifications for a server cabinet

    - by Bingu Bingme
    I'm trying to understand the considerations ("why") that go into determining the specifications ("what") for a rackmount server cabinet, in order to determine what sort of rack I should purchase for my home use. Since this is for home use, I won't be following certain best practices (eg. hot/cold aisle, not even air conditioning) and may be willing to sacrifice in various areas in order to reduce cost and footprint - but please advise if there are safety concerns or other considerations to note. The most basic specs for a server cabinet are the dimensions (external width x external depth x usable height). Width: commonly 600mm or 800mm (if the use case requires extra clearance around the sides, such as if there is lots of cabling). In my case and most common cases, I'm going to stick with 600mm. Height: Select a sufficiently tall rack to fit my equipment. But how much may I stuff into it? Eg, if there is a 15U rack, can I really populate it with 15U of servers, or should I leave 1U at top and bottom for air circulation? Depth: Racks commonly have external depth of 600mm (network equipment), 800mm, 1000mm, or even longer. I'm trying to see how to fit into the 800mm depth. With reference to http://www.server-racks.com/rack-mount-depth.html, I'm hoping to have the front and rear posts mounted ~ 28.5" (72cm) apart, which would leave only 8cm for front space and rear space. How much rear space (from rear posts to back of rack) do I really need? I won't use cable management arms, so can I mount a 72cm depth server since the power, KVM, network cables won't take up much depth? My most important equipment are all < 60cm depth (4U chassis) and should comfortably fit within the 800mm cabinet. The rest of the equipment are very old 1U servers that range from 65-72cm depth. I might still want to make further use of them, or I might discard them since they are so old. Even if the 72cm servers cannot be powered on in an 800mm rack, I should be able to use them as 1U shelves. But, what server depth can I expect to be able to operate? Or am I forced to upgrade to 1000mm depth racks in order to use any servers deeper than 60cm? With reference to best practices for HP racks, some other specs and installation considerations: There aren't any minimum recommendations for clearance on the sides of the rack. It is recommended to leave 48" front clearance. The 48" front clearance is based on 32" chassis depth, 13" to extend the rack rails and mate the inner/outer rails, and 3" for movement. If I don't use such rails (eg, use shelves instead), it should be sufficient to leave front clearance of chassis depth + 3". It is recommended to leave 30" rear clearance "to provide space for servicing the rack". I'm planning to back the rack into a corner of the room, and wheel it slightly out when I need to access the rear. If the wheeling plan is ok, I still need to know how much rear clearance is required for air circulation and ventilation purposes. Castor wheels and stabilising feet. Since I'm backing the rack into a corner of the room, I'll only be able to set the stabilising feet on the front corners. Thoughts on safety? The rack that I'm considering has front glass doors with side ventilation slits and fully perforated rear doors. I'm hoping this will be a good balance between temperature and noise (only ventilation slits facing out the front, while the rear is facing the walls). Or is the sound of high-rpm fans going to escape through the front slits anyway and destroy my sanity?

    Read the article

  • Introducing Oracle VM Server for SPARC

    - by Honglin Su
    As you are watching Oracle's Virtualization Strategy Webcast and exploring the great virtualization offerings of Oracle VM product line, I'd like to introduce Oracle VM Server for SPARC --  highly efficient, enterprise-class virtualization solution for Sun SPARC Enterprise Systems with Chip Multithreading (CMT) technology. Oracle VM Server for SPARC, previously called Sun Logical Domains, leverages the built-in SPARC hypervisor to subdivide supported platforms' resources (CPUs, memory, network, and storage) by creating partitions called logical (or virtual) domains. Each logical domain can run an independent operating system. Oracle VM Server for SPARC provides the flexibility to deploy multiple Oracle Solaris operating systems simultaneously on a single platform. Oracle VM Server also allows you to create up to 128 virtual servers on one system to take advantage of the massive thread scale offered by the CMT architecture. Oracle VM Server for SPARC integrates both the industry-leading CMT capability of the UltraSPARC T1, T2 and T2 Plus processors and the Oracle Solaris operating system. This combination helps to increase flexibility, isolate workload processing, and improve the potential for maximum server utilization. Oracle VM Server for SPARC delivers the following: Leading Price/Performance - The low-overhead architecture provides scalable performance under increasing workloads without additional license cost. This enables you to meet the most aggressive price/performance requirement Advanced RAS - Each logical domain is an entirely independent virtual machine with its own OS. It supports virtual disk mutipathing and failover as well as faster network failover with link-based IP multipathing (IPMP) support. Moreover, it's fully integrated with Solaris FMA (Fault Management Architecture), which enables predictive self healing. CPU Dynamic Resource Management (DRM) - Enable your resource management policy and domain workload to trigger the automatic addition and removal of CPUs. This ability helps you to better align with your IT and business priorities. Enhanced Domain Migrations - Perform domain migrations interactively and non-interactively to bring more flexibility to the management of your virtualized environment. Improve active domain migration performance by compressing memory transfers and taking advantage of cryptographic acceleration hardware. These methods provide faster migration for load balancing, power saving, and planned maintenance. Dynamic Crypto Control - Dynamically add and remove cryptographic units (aka MAU) to and from active domains. Also, migrate active domains that have cryptographic units. Physical-to-virtual (P2V) Conversion - Quickly convert an existing SPARC server running the Oracle Solaris 8, 9 or 10 OS into a virtualized Oracle Solaris 10 image. Use this image to facilitate OS migration into the virtualized environment. Virtual I/O Dynamic Reconfiguration (DR) - Add and remove virtual I/O services and devices without needing to reboot the system. CPU Power Management - Implement power saving by disabling each core on a Sun UltraSPARC T2 or T2 Plus processor that has all of its CPU threads idle. Advanced Network Configuration - Configure the following network features to obtain more flexible network configurations, higher performance, and scalability: Jumbo frames, VLANs, virtual switches for link aggregations, and network interface unit (NIU) hybrid I/O. Official Certification Based On Real-World Testing - Use Oracle VM Server for SPARC with the most sophisticated enterprise workloads under real-world conditions, including Oracle Real Application Clusters (RAC). Affordable, Full-Stack Enterprise Class Support - Obtain worldwide support from Oracle for the entire virtualization environment and workloads together. The support covers hardware, firmware, OS, virtualization, and the software stack. SPARC Server Virtualization Oracle offers a full portfolio of virtualization solutions to address your needs. SPARC is the leading platform to have the hard partitioning capability that provides the physical isolation needed to run independent operating systems. Many customers have already used Oracle Solaris Containers for application isolation. Oracle VM Server for SPARC provides another important feature with OS isolation. This gives you the flexibility to deploy multiple operating systems simultaneously on a single Sun SPARC T-Series server with finer granularity for computing resources.  For SPARC CMT processors, the natural level of granularity is an execution thread, not a time-sliced microsecond of execution resources. Each CPU thread can be treated as an independent virtual processor. The scheduler is naturally built into the CPU for lower overhead and higher performance. Your organizations can couple Oracle Solaris Containers and Oracle VM Server for SPARC with the breakthrough space and energy savings afforded by Sun SPARC Enterprise systems with CMT technology to deliver a more agile, responsive, and low-cost environment. Management with Oracle Enterprise Manager Ops Center The Oracle Enterprise Manager Ops Center Virtualization Management Pack provides full lifecycle management of virtual guests, including Oracle VM Server for SPARC and Oracle Solaris Containers. It helps you streamline operations and reduce downtime. Together, the Virtualization Management Pack and the Ops Center Provisioning and Patch Automation Pack provide an end-to-end management solution for physical and virtual systems through a single web-based console. This solution automates the lifecycle management of physical and virtual systems and is the most effective systems management solution for Oracle's Sun infrastructure. Ease of Deployment with Configuration Assistant The Oracle VM Server for SPARC Configuration Assistant can help you easily create logical domains. After gathering the configuration data, the Configuration Assistant determines the best way to create a deployment to suit your requirements. The Configuration Assistant is available as both a graphical user interface (GUI) and terminal-based tool. Oracle Solaris Cluster HA Support The Oracle Solaris Cluster HA for Oracle VM Server for SPARC data service provides a mechanism for orderly startup and shutdown, fault monitoring and automatic failover of the Oracle VM Server guest domain service. In addition, applications that run on a logical domain, as well as its resources and dependencies can be controlled and managed independently. These are managed as if they were running in a classical Solaris Cluster hardware node. Supported Systems Oracle VM Server for SPARC is supported on all Sun SPARC Enterprise Systems with CMT technology. UltraSPARC T2 Plus Systems ·   Sun SPARC Enterprise T5140 Server ·   Sun SPARC Enterprise T5240 Server ·   Sun SPARC Enterprise T5440 Server ·   Sun Netra T5440 Server ·   Sun Blade T6340 Server Module ·   Sun Netra T6340 Server Module UltraSPARC T2 Systems ·   Sun SPARC Enterprise T5120 Server ·   Sun SPARC Enterprise T5220 Server ·   Sun Netra T5220 Server ·   Sun Blade T6320 Server Module ·   Sun Netra CP3260 ATCA Blade Server Note that UltraSPARC T1 systems are supported on earlier versions of the software.Sun SPARC Enterprise Systems with CMT technology come with the right to use (RTU) of Oracle VM Server, and the software is pre-installed. If you have the systems under warranty or with support, you can download the software and system firmware as well as their updates. Oracle Premier Support for Systems provides fully-integrated support for your server hardware, firmware, OS, and virtualization software. Visit oracle.com/support for information about Oracle's support offerings for Sun systems. For more information about Oracle's virtualization offerings, visit oracle.com/virtualization.

    Read the article

  • Unity: Spin wheels to move vehicle

    - by Paul Manta
    I am just getting started with Unity and I'd like to ask a question. If I have a "Vehicle" object that has two children: "FrontWheel" and "BackWheel" (both 'wheels' are cylinders), how should I set everything up such that I can move the entire vehicle by turning its wheels? When I apply a torque to "FrontWheel", the vehicle starts to move, but instead of the whole thing the moving together, the chassis is rolling on the cylinders and eventually falls off. How can I prevent it from doing that?

    Read the article

  • Cisco UCS Buyer's Guide

    Cisco entered the server market in 2009 with its Unified Computing System, a series of blades and a chassis designed to simplify deployment, particularly for virtualized environments. See how its offerings compare to those of the more established players.

    Read the article

  • Cisco UCS Buyer's Guide

    Cisco entered the server market in 2009 with its Unified Computing System, a series of blades and a chassis designed to simplify deployment, particularly for virtualized environments. See how its offerings compare to those of the more established players.

    Read the article

  • Which server to choose? [closed]

    - by Devbag
    I have telecom applications that I want to run on a server(I have chosen HP server), there are so many types of hp servers i.e DL380 (g3,g4 ....), blade , entry level server. I've surfed the web and nothing is helping me choose one that suites me, what I have is telecom application made in PHP and C. I've found many used DL380 G3,G4 and G5 on craiglist with really good prices, some of them have misssing HD, RAMs and some of them have nothing missing. Can you please help me choose wisely. Thanks,

    Read the article

  • IPMI not fucntioning with Network Bonding

    - by muhammed sameer
    Hey, I am having problems with running IPMI on my servers that have network bonding enabled. Platform: CentOS release 5.3 (Final) Kernel: 2.6.18-92.el5 64bit Dell PowerEdge 1950 Ethernet controller: Broadcom Corporation NetXtreme II BCM5708 Gigabit Ethernet I have bonded the interface eth0 and eth1 as active passive, with eth0 as the active interface, below is conf description from /proc Bonding Mode: fault-tolerance (active-backup) Primary Slave: eth0 Currently Active Slave: eth0 MII Status: up MII Polling Interval (ms): 30 Up Delay (ms): 0 Down Delay (ms): 0 Slave Interface: eth0 MII Status: up Link Failure Count: 0 Permanent HW addr: 00:22:19:56:b9:cd Slave Interface: eth1 MII Status: up Link Failure Count: 0 Permanent HW addr: 00:22:19:56:b9:cf My IPMI device is as follows IPMI Device Information Interface Type: KCS (Keyboard Control Style) Specification Version: 2.0 I2C Slave Address: 0x10 NV Storage Device: Not Present Base Address: 0x0000000000000CA8 (I/O) Register Spacing: 32-bit Boundaries I Have used openIPMI as well as freeipmi both to control the chassis via the IPMI card, but on servers which have bonding enabled, the command times out, below is the full run of the command with debug info. ipmi_lan_send_cmd:opened=[0], open=[4482848] IPMI LAN host 70.87.28.115 port 623 Sending IPMI/RMCP presence ping packet ipmi_lan_send_cmd:opened=[1], open=[4482848] No response from remote controller Get Auth Capabilities command failed ipmi_lan_send_cmd:opened=[1], open=[4482848] No response from remote controller Get Auth Capabilities command failed Error: Unable to establish LAN session Failed to open LAN interface Unable to get Chassis Power Status On the other hand I configured IPMI on a box with the same specs as mentioned above without bonding and IPMI works perfectly. Has anyone faced this problem with IPMI + Bonding ? I would be thankful is someone helps circumvent this issue. Muhammed Sameer

    Read the article

  • Why datacenter water cooling is not widespread?

    - by MainMa
    From what I read and hear about datacenters, there are not too many server rooms which use water cooling, and none of the largerst datacenters use water cooling (correct me if I'm wrong). Also, it's relatively easy to buy an ordinary PC components using water cooling, while water cooled rack servers are nearly nonexistent. On the other hand, using water can possibly (IMO): Reduce the power consumption of large datacenters, especially if it is possible to create direct cooled facilities (i.e. the facility is located near a river or the sea). Reduce noise, making it less painful for humans to work in datacenters. Reduce space needed for the servers: On server level, I imagine that in both rack and blade servers, it's easier to pass the water cooling tubes than to waste space to allow the air to pass inside, On datacenter level, if it's still required to keep the alleys between servers for maintenance access to servers, the empty space under the floor and at the ceiling level used for the air can be removed. So why water cooling systems are not widespread, neither on datacenter level, nor on rack/blade servers level? Is it because: The water cooling is hardly redundant on server level? The direct cost of water cooled facility is too high compared to an ordinary datacenter? It is difficult to maintain such system (regularly cleaning the water cooling system which uses water from a river is of course much more complicated and expensive than just vacuum cleaning the fans)?

    Read the article

  • Communicating via Command Mode with IBM HS22 IMM via AMM

    - by MikeyB
    On previous model blades that contained a BMC, I was able to communicate from our external management station via pass-through commands to the BMC to do things such as power blades on/off, set VPD parameters, reboot the BMC, etc. Now on the HS22, a bunch of things happen differently. For example, we can no longer use the same pass-through commands to write VPD information pages and have them persist across reboots of the IMM - it looks as though those VPD pages are populated from information contained in the IMM. How do we use the Advanced Settings Utility from an external host to communicate with HS22 IMMs? Alternatively, what TCP Command Mode commands do we need to send to the AMM to communicate with the IMM? For our purposes, we specifically cannot communicate with the IMM from the blade itself. Specific example: When I send a pass-thru IPMI command via the AMM to the blade BMC to write information (such as MTM, Serial) into VPD page 0x10, it persists on blades with a BMC (HS21 for example). I can send the same IPMI command to write data to the VPD page on the HS22, however it does not persist across reboots of the IMM. What IPMI commands do I need to send to the IMM? What IPMI commands are asu sending when it sets the MTM & Serial?

    Read the article

  • poor performance when deleteing many files

    - by choppy
    I've got two machines: The first is IBM Blade with 24 cores 96GB RAM and single local hard drive with 278GB divided to 4 partitions: 1. c: - 40GB; 3GB free 2. d: - 40GB; 37GB free 3. e: - 198322GB; 198.1 free 4. 100MB (EFI system Partition) Formatted with GPT The other is pizza server with 4 cores 8GB RAM and single local hard drive with 273GB divided to 3 partitions: 1. c: - 136.81; 20GB free 2. d: - 88.74GB; 87.91 free 3. e: - 47.85GB; 46.91 free Formatted with MBR I have two scripts, the first creates 20,000 files in one directory, each file size is 192KB, the second delete the folder (recursive) and prints how much time it toke to delete all files. The problem is on the first server (blade) it takes about 2 minutes to delete all 20,000 files while on the second (pizza) it takes about 4 seconds!? Both servers have clean windows server 2008R2 with no special application running on background. Any ideas what is going on?

    Read the article

  • Adding more drives to a drive array

    - by Mystere Man
    I have a friend who has two servers, a Dell 1800 and an HP 350 ML G5, both have SAS drive arrays. The Dell is a 3.5" and the HP is a 2.5". They currently only have 3 drives in each array. We want to add additional drives, but they do not appear to have caddies, just "fake" covers. I haven't been able to take a good look at them, so I'm not sure what I need to do here. Are the "sockets" just there, and I can buy additional caddies and just stick them in? Or do I have to buy some kind of caddy adapter? Also, i'm thinking of just going 2.5" in the new server, so is there a 2.5" adapter caddy that will fit in the 3.5" chassis for the Dell, so I can use 2.5" drives in the 3.5" chassis? Can I buy 6GB/s drives and add them to the 3GB/s controller? The reason is that we're going to replace both computers in a year or so, and we want to bring the drives with. So rather than buy 3GB/s drives, we just want to buy 6GB/s drives so they can be used in the new server.

    Read the article

  • Wires from fan on side panel - where do they connect?

    - by Mick
    The side panel of my desktop PC has a small fan built in. There were two wires, one red one black that connected inside the PC. Unfortunately I had the bolts removed and the side door fell off ripping the cables such that the main length of cable remains attached to the fan. So there must be two short stubs of broken cable somewhere - but I can't find them! Any ideas where I should look? I can't see anything on the motherboard. the PC is running perfectly well - but I now have the side open to make sure the air can circulate. EDIT: The motherboard appears to be an "Asus P6T SE" EDIT: The manual shows the location of two "chassis fan" connectors. One is being used by a big chassis fan on the back face of the PC (underneath the pwer supply). The other appears to be unused - there is no stub of a connector with wires - its just the bare pins sticking directly out of the motherboard. There is also an unused "pwr_fan" connector. Would it be ok to simply connect the black and red wires from the fan to the black and red parts of a molex adapter?

    Read the article

  • CodePlex Daily Summary for Friday, August 08, 2014

    CodePlex Daily Summary for Friday, August 08, 2014Popular ReleasesSpace Engineers Server Manager: SESM V1.13: V1.13 - Added the restore option in the backup manager - Reenabled the map upload for the managersStrata v1.1 - Adobe Photoshop Like graphics editor: Strata 1.1: Version Strata 1.1: Available feutures: Drawing a layer; Adding a layer; Deleting a layer; Moving layers; Changing the order of layers; Hide / show layer; Saving as Project; Saving as Picture format (Jpg, Png, Gif) All interface in russian language. Saving - is Ok, But Opening have some display troublesEssence#: Nile (Alpha Build 20): The Nile release introduces ANSI-conformant streams into Essence#. It also fixes some significant bugs, and provides new utility scripts for use in developing Essence# code. The name Nile was chosen because it's the name of a rather big stream that's mentioned in the Bible--and we've been using a Biblical naming scheme for the Alpha releases. Recall that Moses as a babe was found among reeds along the banks of the Nile. So the Nile is a reed stream... FileStream Usage ExamplesTwo new exa...Instant Beautiful Browsing: IBB 14.3 Alpha: An alpha release of IBB. After 3 years of the last release this version is made from scratch, with tons of new features like: Make your own IBB aps. HTML 5. Better UI. Extreme Windows 8 resemblance. Photos. Store. Movement TONS of times smother compared to previous versions. Remember that this is AN ALPHA release, I hope I will have "IBB 14" finished by December. The documentation on how to create a new application for IBB will come next monthjQuery List DragSort: jQuery List DragSort 0.5.2: Fixed scrollContainer removing deprecated use of $.browser so should now work with latest version of jQuery. Added the ability to return false in dragEnd to revert sort order Project changes Added nuget package for dragsort https://www.nuget.org/packages/dragsort Converted repository from SVN to MercurialWix# (WixSharp) - managed interface for WiX: Release 1.0.0.0: Release 1.0.0.0 Custom UI Custom MSI Dialog Custom CLR Dialog External UIRecaptcha for .NET: Recaptcha for .NET v1.6.0: What's New?Bug fixes Optimized codeMath.NET Numerics: Math.NET Numerics v3.2.0: Linear Algebra: Vector.Map2 (map2 in F#), storage-optimized Linear Algebra: fix RemoveColumn/Row early index bound check (was not strict enough) Statistics: Entropy ~Jeff Mastry Interpolation: use Array.BinarySearch instead of local implementation ~Candy Chiu Resources: fix a corrupted exception message string Portable Build: support .Net 4.0 as well by using profile 328 instead of 344. .Net 3.5: F# extensions now support .Net 3.5 as well .Net 3.5: NuGet package now contains pro...AutomatedLab: AutomatedLab 2.2.0.0: 2.2.0 Support for Subordinate Certificate Authorities Installing software does no longer use workflows but background jobs, which is much faster Many performance improvements Removing a lab does no longer require to import it first if using the Path parameter Adjusted all sample scripts to work with version 2.x New validators to verify virtual switch settings Bug fixing 2.1.0 Support for external virtual switches CaRoot is a new role for installing Root Certificate Authorities ...babelua: 1.6.5.1: V1.6.5.1 - 2014.8.7New feature: Formatting code; Stability improvement: fix a bug that pop up error "System.Net.WebResponse EndGetResponse";Virto Commerce Enterprise Open Source eCommerce Platform (asp.net mvc): Virto Commerce 1.11: Virto Commerce Community Edition version 1.11. To install the SDK package, please refer to SDK getting started documentation To configure source code package, please refer to Source code getting started documentation This release includes many bug fixes and minor improvements. More details about this release can be found on our blog at http://blog.virtocommerce.com.Online Resume Parsing Using Aspose.Words for .NET: Resume_Parser: First Release of Resume Parser Application using Aspose.Words for .NET.Blade.Net: 3.0.0.0: Blade.Controls added: collection of MVVM and Prism friendly WPF controls and utilities InteractionRequest based implementation for OpenFile/SafeFile dialogs InteractionRequest based implementation for print dialog Drag&Drop behaviors Focus behaviors TextBox behaviors PopupWindowActionRegionAdapter PropagateInputBindingsToWindowBehavior Blade.Forest added: simple backlog tool Backlog items are structured via drag&drop in one tree Backlog items dragged to and structured in sepa...BBImageHandler - An image generator for DotNetNuke and ASP.NET: 01.06.00: Release notes V 1.6.0Added 2 configuration properties: ServerCacheExpiration (value in seconds,Default: 600 seconds) + ClientCacheExpiration (value in seconds, Default: 300 seconds) Fixed Client Caching (now sending 304 when cache time is not expired) Fixed bug when attaching watermark to indexed image formatRole Based View for Microsoft Dynamic CRM 2011 & 2013: Role based view for MS CRM 2011 Ver. 1.0: One of the very use full features called “Role Based View” in Microsoft Dynamics CRM 2011 & 2013 has been ignored by Microsoft. Now the functionality is provided with this small solution which will allowing you to have different views for an entity that can be assigned to different security roles. For example, Certain Views will not appear for the Sales person since their security level is lower than that of the Sales Manager. However Sales Manager can able to see those additional view.Json.NET: Json.NET 6.0 Release 4: New feature - Added Merge to LINQ to JSON New feature - Added JValue.CreateNull and JValue.CreateUndefined New feature - Added Windows Phone 8.1 support to .NET 4.0 portable assembly New feature - Added OverrideCreator to JsonObjectContract New feature - Added support for overriding the creation of interfaces and abstract types New feature - Added support for reading UUID BSON binary values as a Guid New feature - Added MetadataPropertyHandling.Ignore New feature - Improv...VidCoder: 1.5.24 Beta: Added NL-Means denoiser. Updated HandBrake core to SVN 6254. Added extra error handling to DVD player code to avoid a crash when the player was moved.PowerShell App Deployment Toolkit: PowerShell App Deployment Toolkit v3.1.5: *Added Send-Keys function to send a sequence of keys to an application window (Thanks to mmashwani) *Added 3 optimization/stability improvements to Execute-Process following MS best practice (Thanks to mmashwani) *Fixed issue where Execute-MSI did not use value from XML file for uninstall but instead ran all uninstalls silently by default *Fixed error on 1641 exit code (should be a success like 3010) *Fixed issue with error handling in Invoke-SCCMTask *Fixed issue with deferral dates where th...SEToolbox: SEToolbox 01.041.012 Release 1: Added voxel material textures to read in with mods. Fixed missing texture replacements for mods. Fixed rounding issue in raytrace code. Fixed repair issue with corrupt checkpoint file. Fixed issue with updated SE binaries 01.041.012 using new container configuration.Magick.NET: Magick.NET 6.8.9.601: Magick.NET linked with ImageMagick 6.8.9.6 Breaking changes: - Changed arguments for the Map method of MagickImage. - QuantizeSettings uses Riemersma by default.New ProjectsBaidu BCS: Baidu BCS (Baidu Cloud Storage) Server SDK. ????????SDK. .NET 4.0 or above. .NET 4.0?????Close Eye Assistant: a Close Eye Assistant using python3Dynamics AX IEIDE Project Explorer: This project is aiming to provide a set of useful features for Dynamics AX developers as well as administrators and is provided as an installable axmodel file.EFlogger - profiler for Entity Framework: Free and simple open source profiler for Entity Framework from 4-6 versionGuitar: i will continue to improve it.jQuery Table Pager Plugin: Simple jQuery plugin to paginate a table. JSJD: ????LFramework: LFrameworkMSDIS MVC Web: Sample ASP.NET MVC 4.0 using AngularJSPJS2: Not complete Powershell implementation in JavaScript.Seemile: SeemileShippety: Shippety is a web application for buying and printing postage labels. It's a client implementation for the EasyPost API written in HTML, Javascript and ASP.NET.Spending Monitor: With this application the user has the ability to create categories, retailers, and payment methods to track their spending in those categories. Strata v1.1 - Adobe Photoshop Like graphics editor: Strata - a graphical editor with layers mechanism similar to Adobe Photoshop. Layer - flat two-dimensional bitmap, where you can draw with the mouse.surfingkata: aTIKSN PowerShell Cmdlets: Bunch of cmdlets developed by TIKSN Lab???????: dfg???????: ????????????????: cvbvcbcv

    Read the article

  • Sun Fire X4800 M2 Posts World Record x86 SPECjEnterprise2010 Result

    - by Brian
    Oracle's Sun Fire X4800 M2 using the Intel Xeon E7-8870 processor and Sun Fire X4470 M2 using the Intel Xeon E7-4870 processor, produced a world record single application server SPECjEnterprise2010 benchmark result of 27,150.05 SPECjEnterprise2010 EjOPS. The Sun Fire X4800 M2 server ran the application tier and the Sun Fire X4470 M2 server was used for the database tier. The Sun Fire X4800 M2 server demonstrated 63% better performance compared to IBM P780 server result of 16,646.34 SPECjEnterprise2010 EjOPS. The Sun Fire X4800 M2 server demonstrated 4% better performance than the Cisco UCS B440 M2 result, both results used the same number of processors. This result used Oracle WebLogic Server 12c, Java HotSpot(TM) 64-Bit Server 1.7.0_02, and Oracle Database 11g. This result was produced using Oracle Linux. Performance Landscape Complete benchmark results are at the SPEC website, SPECjEnterprise2010 Results. The table below compares against the best results from IBM and Cisco. SPECjEnterprise2010 Performance Chart as of 3/12/2012 Submitter EjOPS* Application Server Database Server Oracle 27,150.05 1x Sun Fire X4800 M2 8x 2.4 GHz Intel Xeon E7-8870 Oracle WebLogic 12c 1x Sun Fire X4470 M2 4x 2.4 GHz Intel Xeon E7-4870 Oracle Database 11g (11.2.0.2) Cisco 26,118.67 2x UCS B440 M2 Blade Server 4x 2.4 GHz Intel Xeon E7-4870 Oracle WebLogic 11g (10.3.5) 1x UCS C460 M2 Blade Server 4x 2.4 GHz Intel Xeon E7-4870 Oracle Database 11g (11.2.0.2) IBM 16,646.34 1x IBM Power 780 8x 3.86 GHz POWER 7 WebSphere Application Server V7 1x IBM Power 750 Express 4x 3.55 GHz POWER 7 IBM DB2 9.7 Workgroup Server Edition FP3a * SPECjEnterprise2010 EjOPS, bigger is better. Configuration Summary Application Server: 1 x Sun Fire X4800 M2 8 x 2.4 GHz Intel Xeon processor E7-8870 256 GB memory 4 x 10 GbE NIC 2 x FC HBA Oracle Linux 5 Update 6 Oracle WebLogic Server 11g Release 1 (10.3.5) Java HotSpot(TM) 64-Bit Server VM on Linux, version 1.7.0_02 (Java SE 7 Update 2) Database Server: 1 x Sun Fire X4470 M2 4 x 2.4 GHz Intel Xeon E7-4870 512 GB memory 4 x 10 GbE NIC 2 x FC HBA 2 x Sun StorageTek 2540 M2 4 x Sun Fire X4270 M2 4 x Sun Storage F5100 Flash Array Oracle Linux 5 Update 6 Oracle Database 11g Enterprise Edition Release 11.2.0.2 Benchmark Description SPECjEnterprise2010 is the third generation of the SPEC organization's J2EE end-to-end industry standard benchmark application. The SPECjEnterprise2010 benchmark has been designed and developed to cover the Java EE 5 specification's significantly expanded and simplified programming model, highlighting the major features used by developers in the industry today. This provides a real world workload driving the Application Server's implementation of the Java EE specification to its maximum potential and allowing maximum stressing of the underlying hardware and software systems. The workload consists of an end to end web based order processing domain, an RMI and Web Services driven manufacturing domain and a supply chain model utilizing document based Web Services. The application is a collection of Java classes, Java Servlets, Java Server Pages, Enterprise Java Beans, Java Persistence Entities (pojo's) and Message Driven Beans. The SPECjEnterprise2010 benchmark heavily exercises all parts of the underlying infrastructure that make up the application environment, including hardware, JVM software, database software, JDBC drivers, and the system network. The primary metric of the SPECjEnterprise2010 benchmark is jEnterprise Operations Per Second ("SPECjEnterprise2010 EjOPS"). This metric is calculated by adding the metrics of the Dealership Management Application in the Dealer Domain and the Manufacturing Application in the Manufacturing Domain. There is no price/performance metric in this benchmark. Key Points and Best Practices Sixteen Oracle WebLogic server instances were started using numactl, binding 2 instances per chip. Eight Oracle database listener processes were started, binding 2 instances per chip using taskset. Additional tuning information is in the report at http://spec.org. See Also Oracle Press Release -- SPECjEnterprise2010 Results Page Sun Fire X4800 M2 Server oracle.com OTN Sun Fire X4270 M2 Server oracle.com OTN Sun Storage 2540-M2 Array oracle.com OTN Oracle Linux oracle.com OTN Oracle Database 11g Release 2 Enterprise Edition oracle.com OTN WebLogic Suite oracle.com OTN Disclosure Statement SPEC and the benchmark name SPECjEnterprise are registered trademarks of the Standard Performance Evaluation Corporation. Sun Fire X4800 M2, 27,150.05 SPECjEnterprise2010 EjOPS; IBM Power 780, 16,646.34 SPECjEnterprise2010 EjOPS; Cisco UCS B440 M2, 26,118.67 SPECjEnterprise2010 EjOPS. Results from www.spec.org as of 3/27/2012.

    Read the article

  • SPARC T5-4 LDoms for RAC and WebLogic Clusters

    - by Jeff Taylor-Oracle
    I wanted to use two Oracle SPARC T5-4 servers to simultaneously host both Oracle RAC and a WebLogic Server Cluster. I chose to use Oracle VM Server for SPARC to create a cluster like this: There are plenty of trade offs and decisions that need to be made, for example: Rather than configuring the system by hand, you might want to use an Oracle SuperCluster T5-8 My configuration is similar to jsavit's: Availability Best Practices - Example configuring a T5-8 but I chose to ignore some of the advice. Maybe I should have included an  alternate service domain, but I decided that I already had enough redundancy Both Oracle SPARC T5-4 servers were to be configured like this: Cntl 0.25  4  64GB                     App LDom                    2.75 CPU's                                        44 cores                                          704 GB              DB LDom      One CPU         16 cores         256 GB   The systems started with everything in the primary domain: # ldm list NAME             STATE      FLAGS   CONS    VCPU  MEMORY   UTIL  NORM  UPTIME primary          active     -n-c--  UART    512   1023G    0.0%  0.0%  11m # ldm list-spconfig factory-default [current] primary # ldm list -o core,memory,physio NAME              primary           CORE     CID    CPUSET     0      (0, 1, 2, 3, 4, 5, 6, 7)     1      (8, 9, 10, 11, 12, 13, 14, 15)     2      (16, 17, 18, 19, 20, 21, 22, 23) -- SNIP     62     (496, 497, 498, 499, 500, 501, 502, 503)     63     (504, 505, 506, 507, 508, 509, 510, 511) MEMORY     RA               PA               SIZE                 0x30000000       0x30000000       255G     0x80000000000    0x80000000000    256G     0x100000000000   0x100000000000   256G     0x180000000000   0x180000000000   256G # Give this memory block to the DB LDom IO     DEVICE                           PSEUDONYM        OPTIONS     pci@300                          pci_0                pci@340                          pci_1                pci@380                          pci_2                pci@3c0                          pci_3                pci@400                          pci_4                pci@440                          pci_5                pci@480                          pci_6                pci@4c0                          pci_7                pci@300/pci@1/pci@0/pci@6        /SYS/RCSA/PCIE1     pci@300/pci@1/pci@0/pci@c        /SYS/RCSA/PCIE2     pci@300/pci@1/pci@0/pci@4/pci@0/pci@c /SYS/MB/SASHBA0     pci@300/pci@1/pci@0/pci@4/pci@0/pci@8 /SYS/RIO/NET0        pci@340/pci@1/pci@0/pci@6        /SYS/RCSA/PCIE3     pci@340/pci@1/pci@0/pci@c        /SYS/RCSA/PCIE4     pci@380/pci@1/pci@0/pci@a        /SYS/RCSA/PCIE9     pci@380/pci@1/pci@0/pci@4        /SYS/RCSA/PCIE10     pci@3c0/pci@1/pci@0/pci@e        /SYS/RCSA/PCIE11     pci@3c0/pci@1/pci@0/pci@8        /SYS/RCSA/PCIE12     pci@400/pci@1/pci@0/pci@e        /SYS/RCSA/PCIE5     pci@400/pci@1/pci@0/pci@8        /SYS/RCSA/PCIE6     pci@440/pci@1/pci@0/pci@e        /SYS/RCSA/PCIE7     pci@440/pci@1/pci@0/pci@8        /SYS/RCSA/PCIE8     pci@480/pci@1/pci@0/pci@a        /SYS/RCSA/PCIE13     pci@480/pci@1/pci@0/pci@4        /SYS/RCSA/PCIE14     pci@4c0/pci@1/pci@0/pci@8        /SYS/RCSA/PCIE15     pci@4c0/pci@1/pci@0/pci@4        /SYS/RCSA/PCIE16     pci@4c0/pci@1/pci@0/pci@c/pci@0/pci@c /SYS/MB/SASHBA1     pci@4c0/pci@1/pci@0/pci@c/pci@0/pci@4 /SYS/RIO/NET2    Added an additional service processor configuration: # ldm add-spconfig split # ldm list-spconfig factory-default primary split [current] And removed many of the resources from the primary domain: # ldm start-reconf primary # ldm set-core 4 primary # ldm set-memory 32G primary # ldm rm-io pci@340 primary # ldm rm-io pci@380 primary # ldm rm-io pci@3c0 primary # ldm rm-io pci@400 primary # ldm rm-io pci@440 primary # ldm rm-io pci@480 primary # ldm rm-io pci@4c0 primary # init 6 Needed to add resources to the guest domains: # ldm add-domain db # ldm set-core cid=`seq -s"," 48 63` db # ldm add-memory mblock=0x180000000000:256G db # ldm add-io pci@480 db # ldm add-io pci@4c0 db # ldm add-domain app # ldm set-core 44 app # ldm set-memory 704G  app # ldm add-io pci@340 app # ldm add-io pci@380 app # ldm add-io pci@3c0 app # ldm add-io pci@400 app # ldm add-io pci@440 app Needed to set up services: # ldm add-vds primary-vds0 primary # ldm add-vcc port-range=5000-5100 primary-vcc0 primary Needed to add a virtual network port for the WebLogic application domain: # ipadm NAME              CLASS/TYPE STATE        UNDER      ADDR lo0               loopback   ok           --         --    lo0/v4         static     ok           --         ...    lo0/v6         static     ok           --         ... net0              ip         ok           --         ...    net0/v4        static     ok           --         xxx.xxx.xxx.xxx/24    net0/v6        addrconf   ok           --         ....    net0/v6        addrconf   ok           --         ... net8              ip         ok           --         --    net8/v4        static     ok           --         ... # dladm show-phys LINK              MEDIA                STATE      SPEED  DUPLEX    DEVICE net1              Ethernet             unknown    0      unknown   ixgbe1 net0              Ethernet             up         1000   full      ixgbe0 net8              Ethernet             up         10     full      usbecm2 # ldm add-vsw net-dev=net0 primary-vsw0 primary # ldm add-vnet vnet1 primary-vsw0 app Needed to add a virtual disk to the WebLogic application domain: # format Searching for disks...done AVAILABLE DISK SELECTIONS:        0. c0t5000CCA02505F874d0 <HITACHI-H106060SDSUN600G-A2B0-558.91GB>           /scsi_vhci/disk@g5000cca02505f874           /dev/chassis/SPARC_T5-4.AK00084038/SYS/SASBP0/HDD0/disk        1. c0t5000CCA02506C468d0 <HITACHI-H106060SDSUN600G-A2B0-558.91GB>           /scsi_vhci/disk@g5000cca02506c468           /dev/chassis/SPARC_T5-4.AK00084038/SYS/SASBP0/HDD1/disk        2. c0t5000CCA025067E5Cd0 <HITACHI-H106060SDSUN600G-A2B0-558.91GB>           /scsi_vhci/disk@g5000cca025067e5c           /dev/chassis/SPARC_T5-4.AK00084038/SYS/SASBP0/HDD2/disk        3. c0t5000CCA02506C258d0 <HITACHI-H106060SDSUN600G-A2B0-558.91GB>           /scsi_vhci/disk@g5000cca02506c258           /dev/chassis/SPARC_T5-4.AK00084038/SYS/SASBP0/HDD3/disk Specify disk (enter its number): ^C # ldm add-vdsdev /dev/dsk/c0t5000CCA02506C468d0s2 HDD1@primary-vds0 # ldm add-vdisk HDD1 HDD1@primary-vds0 app Add some additional spice to the pot: # ldm set-variable auto-boot\\?=false db # ldm set-variable auto-boot\\?=false app # ldm set-var boot-device=HDD1 app Bind the logical domains: # ldm bind db # ldm bind app At the end of the process, the system is set up like this: # ldm list -o core,memory,physio NAME             primary          CORE     CID    CPUSET     0      (0, 1, 2, 3, 4, 5, 6, 7)     1      (8, 9, 10, 11, 12, 13, 14, 15)     2      (16, 17, 18, 19, 20, 21, 22, 23)     3      (24, 25, 26, 27, 28, 29, 30, 31) MEMORY     RA               PA               SIZE                0x30000000       0x30000000       32G IO     DEVICE                           PSEUDONYM        OPTIONS     pci@300                          pci_0               pci@300/pci@1/pci@0/pci@6        /SYS/RCSA/PCIE1     pci@300/pci@1/pci@0/pci@c        /SYS/RCSA/PCIE2     pci@300/pci@1/pci@0/pci@4/pci@0/pci@c /SYS/MB/SASHBA0     pci@300/pci@1/pci@0/pci@4/pci@0/pci@8 /SYS/RIO/NET0   ------------------------------------------------------------------------------ NAME             app              CORE     CID    CPUSET     4      (32, 33, 34, 35, 36, 37, 38, 39)     5      (40, 41, 42, 43, 44, 45, 46, 47)     6      (48, 49, 50, 51, 52, 53, 54, 55)     7      (56, 57, 58, 59, 60, 61, 62, 63)     8      (64, 65, 66, 67, 68, 69, 70, 71)     9      (72, 73, 74, 75, 76, 77, 78, 79)     10     (80, 81, 82, 83, 84, 85, 86, 87)     11     (88, 89, 90, 91, 92, 93, 94, 95)     12     (96, 97, 98, 99, 100, 101, 102, 103)     13     (104, 105, 106, 107, 108, 109, 110, 111)     14     (112, 113, 114, 115, 116, 117, 118, 119)     15     (120, 121, 122, 123, 124, 125, 126, 127)     16     (128, 129, 130, 131, 132, 133, 134, 135)     17     (136, 137, 138, 139, 140, 141, 142, 143)     18     (144, 145, 146, 147, 148, 149, 150, 151)     19     (152, 153, 154, 155, 156, 157, 158, 159)     20     (160, 161, 162, 163, 164, 165, 166, 167)     21     (168, 169, 170, 171, 172, 173, 174, 175)     22     (176, 177, 178, 179, 180, 181, 182, 183)     23     (184, 185, 186, 187, 188, 189, 190, 191)     24     (192, 193, 194, 195, 196, 197, 198, 199)     25     (200, 201, 202, 203, 204, 205, 206, 207)     26     (208, 209, 210, 211, 212, 213, 214, 215)     27     (216, 217, 218, 219, 220, 221, 222, 223)     28     (224, 225, 226, 227, 228, 229, 230, 231)     29     (232, 233, 234, 235, 236, 237, 238, 239)     30     (240, 241, 242, 243, 244, 245, 246, 247)     31     (248, 249, 250, 251, 252, 253, 254, 255)     32     (256, 257, 258, 259, 260, 261, 262, 263)     33     (264, 265, 266, 267, 268, 269, 270, 271)     34     (272, 273, 274, 275, 276, 277, 278, 279)     35     (280, 281, 282, 283, 284, 285, 286, 287)     36     (288, 289, 290, 291, 292, 293, 294, 295)     37     (296, 297, 298, 299, 300, 301, 302, 303)     38     (304, 305, 306, 307, 308, 309, 310, 311)     39     (312, 313, 314, 315, 316, 317, 318, 319)     40     (320, 321, 322, 323, 324, 325, 326, 327)     41     (328, 329, 330, 331, 332, 333, 334, 335)     42     (336, 337, 338, 339, 340, 341, 342, 343)     43     (344, 345, 346, 347, 348, 349, 350, 351)     44     (352, 353, 354, 355, 356, 357, 358, 359)     45     (360, 361, 362, 363, 364, 365, 366, 367)     46     (368, 369, 370, 371, 372, 373, 374, 375)     47     (376, 377, 378, 379, 380, 381, 382, 383) MEMORY     RA               PA               SIZE                0x30000000       0x830000000      192G     0x4000000000     0x80000000000    256G     0x8080000000     0x100000000000   256G IO     DEVICE                           PSEUDONYM        OPTIONS     pci@340                          pci_1               pci@380                          pci_2               pci@3c0                          pci_3               pci@400                          pci_4               pci@440                          pci_5               pci@340/pci@1/pci@0/pci@6        /SYS/RCSA/PCIE3     pci@340/pci@1/pci@0/pci@c        /SYS/RCSA/PCIE4     pci@380/pci@1/pci@0/pci@a        /SYS/RCSA/PCIE9     pci@380/pci@1/pci@0/pci@4        /SYS/RCSA/PCIE10     pci@3c0/pci@1/pci@0/pci@e        /SYS/RCSA/PCIE11     pci@3c0/pci@1/pci@0/pci@8        /SYS/RCSA/PCIE12     pci@400/pci@1/pci@0/pci@e        /SYS/RCSA/PCIE5     pci@400/pci@1/pci@0/pci@8        /SYS/RCSA/PCIE6     pci@440/pci@1/pci@0/pci@e        /SYS/RCSA/PCIE7     pci@440/pci@1/pci@0/pci@8        /SYS/RCSA/PCIE8 ------------------------------------------------------------------------------ NAME             db               CORE     CID    CPUSET     48     (384, 385, 386, 387, 388, 389, 390, 391)     49     (392, 393, 394, 395, 396, 397, 398, 399)     50     (400, 401, 402, 403, 404, 405, 406, 407)     51     (408, 409, 410, 411, 412, 413, 414, 415)     52     (416, 417, 418, 419, 420, 421, 422, 423)     53     (424, 425, 426, 427, 428, 429, 430, 431)     54     (432, 433, 434, 435, 436, 437, 438, 439)     55     (440, 441, 442, 443, 444, 445, 446, 447)     56     (448, 449, 450, 451, 452, 453, 454, 455)     57     (456, 457, 458, 459, 460, 461, 462, 463)     58     (464, 465, 466, 467, 468, 469, 470, 471)     59     (472, 473, 474, 475, 476, 477, 478, 479)     60     (480, 481, 482, 483, 484, 485, 486, 487)     61     (488, 489, 490, 491, 492, 493, 494, 495)     62     (496, 497, 498, 499, 500, 501, 502, 503)     63     (504, 505, 506, 507, 508, 509, 510, 511) MEMORY     RA               PA               SIZE                0x80000000       0x180000000000   256G IO     DEVICE                           PSEUDONYM        OPTIONS     pci@480                          pci_6               pci@4c0                          pci_7               pci@480/pci@1/pci@0/pci@a        /SYS/RCSA/PCIE13     pci@480/pci@1/pci@0/pci@4        /SYS/RCSA/PCIE14     pci@4c0/pci@1/pci@0/pci@8        /SYS/RCSA/PCIE15     pci@4c0/pci@1/pci@0/pci@4        /SYS/RCSA/PCIE16     pci@4c0/pci@1/pci@0/pci@c/pci@0/pci@c /SYS/MB/SASHBA1     pci@4c0/pci@1/pci@0/pci@c/pci@0/pci@4 /SYS/RIO/NET2   Start the domains: # ldm start app LDom app started # ldm start db LDom db started Make sure to start the vntsd service that was created, above. # svcs -a | grep ldo disabled        8:38:38 svc:/ldoms/vntsd:default online          8:38:58 svc:/ldoms/agents:default online          8:39:25 svc:/ldoms/ldmd:default # svcadm enable vntsd Now use the MAC address to configure the Solaris 11 Automated Installation. Database Logical Domain # telnet localhost 5000 {0} ok devalias screen                   /pci@4c0/pci@1/pci@0/pci@c/pci@0/pci@7/display@0 disk7                    /pci@4c0/pci@1/pci@0/pci@c/pci@0/pci@c/scsi@0/disk@p3 disk6                    /pci@4c0/pci@1/pci@0/pci@c/pci@0/pci@c/scsi@0/disk@p2 disk5                    /pci@4c0/pci@1/pci@0/pci@c/pci@0/pci@c/scsi@0/disk@p1 disk4                    /pci@4c0/pci@1/pci@0/pci@c/pci@0/pci@c/scsi@0/disk@p0 scsi1                    /pci@4c0/pci@1/pci@0/pci@c/pci@0/pci@c/scsi@0 net3                     /pci@4c0/pci@1/pci@0/pci@c/pci@0/pci@4/network@0,1 net2                     /pci@4c0/pci@1/pci@0/pci@c/pci@0/pci@4/network@0 virtual-console          /virtual-devices/console@1 name                     aliases {0} ok boot net2 Boot device: /pci@4c0/pci@1/pci@0/pci@c/pci@0/pci@4/network@0  File and args: 1000 Mbps full duplex Link up Requesting Internet Address for xx:xx:xx:xx:xx:xx Requesting Internet Address for xx:xx:xx:xx:xx:xx WLS Logical Domain # telnet localhost 5001 {0} ok devalias hdd1                     /virtual-devices@100/channel-devices@200/disk@0 vnet1                    /virtual-devices@100/channel-devices@200/network@0 net                      /virtual-devices@100/channel-devices@200/network@0 disk                     /virtual-devices@100/channel-devices@200/disk@0 virtual-console          /virtual-devices/console@1 name                     aliases {0} ok boot net Boot device: /virtual-devices@100/channel-devices@200/network@0  File and args: Requesting Internet Address for xx:xx:xx:xx:xx:xx Requesting Internet Address for xx:xx:xx:xx:xx:xx Repeat the process for the second SPARC T5-4, install Solaris, RAC and WebLogic Cluster, and you are ready to go. Maybe buying a SuperCluster would have been easier.

    Read the article

  • What is the worst programming language you ever worked with? [closed]

    - by Ludwig Weinzierl
    If you have an interesting story to share, please post an answer, but do not abuse this question for bashing a language. We are programmers, and our primary tool is the programming language we use. While there is a lot of discussion about the best one, I'd like to hear your stories about the worst programming languages you ever worked with and I'd like to know exactly what annoyed you. I'd like to collect this stories partly to avoid common pitfalls while designing a language (especially a DSL) and partly to avoid quirky languages in the future in general. This question is not subjective. If a language supports only single character identifiers (see my own answer) this is bad in a non-debatable way. EDIT Some people have raised concerns that this question attracts trolls. Wading through all your answers made one thing clear. The large majority of answers is appropriate, useful and well written. UPDATE 2009-07-01 19:15 GMT The language overview is now complete, covering 103 different languages from 102 answers. I decided to be lax about what counts as a programming language and included anything reasonable. Thank you David for your comments on this. Here are all programming languages covered so far (alphabetical order, linked with answer, new entries in bold): ABAP, all 20th century languages, all drag and drop languages, all proprietary languages, APF, APL (1), AS400, Authorware, Autohotkey, BancaStar, BASIC, Bourne Shell, Brainfuck, C++, Centura Team Developer, Cobol (1), Cold Fusion, Coldfusion, CRM114, Crystal Syntax, CSS, Dataflex 2.3, DB/c DX, dbase II, DCL, Delphi IDE, Doors DXL, DOS batch (1), Excel Macro language, FileMaker, FOCUS, Forth, FORTRAN, FORTRAN 77, HTML, Illustra web blade, Informix 4th Generation Language, Informix Universal Server web blade, INTERCAL, Java, JavaScript (1), JCL (1), karol, LabTalk, Labview, Lingo, LISP, Logo, LOLCODE, LotusScript, m4, Magic II, Makefiles, MapBasic, MaxScript, Meditech Magic, MEL, mIRC Script, MS Access, MUMPS, Oberon, object extensions to C, Objective-C, OPS5, Oz, Perl (1), PHP, PL/SQL, PowerDynamo, PROGRESS 4GL, prova, PS-FOCUS, Python, Regular Expressions, RPG, RPG II, Scheme, ScriptMaker, sendmail.conf, Smalltalk, Smalltalk , SNOBOL, SpeedScript, Sybase PowerBuilder, Symbian C++, System RPL, TCL, TECO, The Visual Software Environment, Tiny praat, TransCAD, troff, uBasic, VB6 (1), VBScript (1), VDF4, Vimscript, Visual Basic (1), Visual C++, Visual Foxpro, VSE, Webspeed, XSLT The answers covering 80386 assembler, VB6 and VBScript have been removed.

    Read the article

  • Web service SSL handshake fails in production environment unless SSL debugging enabled

    - by JST
    Scenario: calling a client web service over SSL (https) with mutual SSL authentication. Different service endpoint URLs and certs (both keystore and truststore) for test vs. production environments. Both test and production environments run tomcat / JBoss clustered. Production environment has load balancing / BigIP, runs Blade and non-Blade machines. Truststore is set (using -Djavax.net.ssl.trustStore=value) at startup. Keystore is set using System.setProperty("javax.net.ssl.keyStore", "value") in Java code. Web service call made using Axis2. All works fine in test environment, but when we moved to production environment (6 servers), it appears certs are not being forwarded for the handshake. Here's what we've done: in test environment, handshake using test versions of certs has been working all along, with no ssl debugging enabled confirmed in test environment that handshake with client production endpoint succeeds (production certs, both ours and theirs, are fine) -- this was done using -Djavax.net.debug=handshake,ssl confirmed that the error condition occurs on all 6 production servers took one server out of the cluster, turned on ssl debugging for just that one (with a restart), hit it directly, handshake works! switched to a different server without the debugging turned on, handshake error condition occurs turned debugging on on that second server (with a restart), hit it directly, handshake works! From the evidence, it seems like somehow the debugging being enabled causes the certificates to be properly retrieved/conveyed, although that makes no sense! I wonder whether somehow the enabled debugging makes the system pay attention to the System.setProperty call, and ignore it otherwise. However, in local and test environments, handshake worked without debugging enabled. Do I maybe need to be setting keystore on server startup like I'm setting truststore? Have been avoiding that because the keystore will differ for each of our test environments (16 of them).

    Read the article

< Previous Page | 1 2 3 4 5 6 7 8 9 10 11  | Next Page >