Search Results

Search found 4308 results on 173 pages for 'vmware infrastructure'.

Page 90/173 | < Previous Page | 86 87 88 89 90 91 92 93 94 95 96 97  | Next Page >

  • 11gR2 ???:Oracle Cluster Health Monitor(CHM)??

    - by JaneZhang(???)
       Cluster Health Monitor(????CHM)???Oracle?????,?????????????(CPU????SWAP????I/O?????)??????CHM??????????   ??????????????????????Hang?????(Eviction)????????????????,??????CHM????????????????????,????????????? CHM???????????:    11.2.0.2 ?????? Oracle Grid Infrastructure for Linux (???Linux Itanium) ?Solaris (Sparc 64 ? x86-64)    11.2.0.3 ????? Oracle Grid Infrastructure for AIX ? Windows (???Windows Itanium)?    ????,???????????CHM?????(ora.crf)???:    $ crsctl stat res -t -init    --------------------------------------------------------------------------------    NAME           TARGET  STATE        SERVER                   STATE_DETAILS       Cluster Resources ora.crf        ONLINE  ONLINE       rac1 CHM????????:    1). System Monitor Service(osysmond):?????????????,osysmond????????????????cluster logger service,???????????????????CHM?????      $ ps -ef|grep osysmond       root      7984     1  0 Jun05 ?        01:16:14 /u01/app/11.2.0/grid/bin/osysmond.bin    2). Cluster Logger Service(ologgerd):???????,ologgerd ???????(master),???????(standby)??ologgerd???????????????,??????????     ???:     $ ps -ef|grep ologgerd       root      8257     1  0 Jun05 ?        00:38:26 /u01/app/11.2.0/grid/bin/ologgerd -M -d       /u01/app/11.2.0/grid/crf/db/rac2     ???:      $ ps -ef|grep ologgerd       root      8353     1  0 Jun05 ?        00:18:47 /u01/app/11.2.0/grid/bin/ologgerd -m rac2 -r -d /u01/app/11.2.0/grid/crf/db/rac1 CHM Repository:?????????,?????,????Grid Infrastructure home ? ,??1 GB ?????,???????????0.5GB???? ?????OCLUMON??????????????????(??????3????)? ??????????????:     $ oclumon manage -get reppath       CHM Repository Path = /u01/app/11.2.0/grid/crf/db/rac2       Done     $ oclumon manage -get repsize       CHM Repository Size = 68082 <====????       Done     ????:     $ oclumon manage -repos reploc /shared/oracle/chm      ????:     $ oclumon manage -repos resize 68083 <==?3600(??) ? 259200(3?)??      rac1 --> retention check successful      New retention is 68083 and will use 1073750609 bytes of disk space      CRS-9115-Cluster Health Monitor repository size change completed on all nodes.      Done ??CHM???????????:     1. ?????Grid_home/bin/diagcollection.pl:         1). ??,??cluster logger service????:         $ oclumon manage -get master         Master = rac2         2).?root??????rac2???????:         # <Grid_home>/bin/diagcollection.pl -collect -chmos -incidenttime inc_time -incidentduration duration         inc_time?????????????,???MM/DD/YYYY24HH:MM:SS, duration??????????????????         ??:# diagcollection.pl -collect -crshome /u01/app/11.2.0/grid -chmoshome  /u01/app/11.2.0/grid -chmos -incidenttime 06/15/201215:30:00 -incidentduration 00:05       3).????????,CHM?????????chmosData_rac2_20120615_1537.tar.gz?    2. ??????CHM?????????oclumon:        $oclumon dumpnodeview [[-allnodes] | [-n node1 node2] [-last "duration"] | [-s "time_stamp" -e "time_stamp"] [-v] [-warning]] [-h]        -s??????,-e??????        $ oclumon dumpnodeview -allnodes -v -s "2012-06-15 07:40:00" -e "2012-06-15 07:57:00" > /tmp/chm1.txt       $ oclumon dumpnodeview -n node1 node2 node3 -last "12:00:00" >/tmp/chm1.txt       $ oclumon dumpnodeview -allnodes -last "00:15:00" >/tmp/chm1.txt ???/tmp/chm1.txt??????:----------------------------------------Node: rac1 Clock: '06-15-12 07.40.01' SerialNo:168880----------------------------------------SYSTEM:#cpus: 1 cpu: 17.96 cpuq: 5 physmemfree: 32240 physmemtotal: 2065856 mcache: 1064024 swapfree: 3988376 swaptotal: 4192956 ior: 57 iow: 59 ios: 10 swpin: 0 swpout: 0 pgin: 57 pgout: 59 netr: 65.767 netw: 34.871 procs: 183 rtprocs: 10 #fds: 4902 #sysfdlimit: 6815744 #disks: 4 #nics: 3  nicErrors: 0TOP CONSUMERS:topcpu: 'mrtg(32385) 64.70' topprivmem: 'ologgerd(8353) 84068' topshm: 'oracle(8760) 329452' topfd: 'ohasd.bin(6627) 720' topthread: 'crsd.bin(8235) 44'PROCESSES:name: 'mrtg' pid: 32385 #procfdlimit: 65536 cpuusage: 64.70 privmem: 1160 shm: 1584 #fd: 5 #threads: 1 priority: 20 nice: 0name: 'oracle' pid: 32381 #procfdlimit: 65536 cpuusage: 0.29 privmem: 1456 shm: 12444 #fd: 32 #threads: 1 priority: 15 nice: 0...name: 'oracle' pid: 8756 #procfdlimit: 65536 cpuusage: 0.0 privmem: 2892 shm: 24356 #fd: 47 #threads: 1 priority: 16 nice: 0----------------------------------------Node: rac2 Clock: '06-15-12 07.40.02' SerialNo:168878----------------------------------------SYSTEM:#cpus: 1 cpu: 40.72 cpuq: 8 physmemfree: 34072 physmemtotal: 2065856 mcache: 1005636 swapfree: 3991808 swaptotal: 4192956 ior: 54 iow: 104 ios: 11 swpin: 0 swpout: 0 pgin: 54 pgout: 104 netr: 77.817 netw: 33.008 procs: 178 rtprocs: 10 #fds: 4948 #sysfdlimit: 6815744 #disks: 4 #nics: 4  nicErrors: 0TOP CONSUMERS:topcpu: 'orarootagent.bi(8490) 1.59' topprivmem: 'ologgerd(8257) 83108' topshm: 'oracle(8873) 324868' topfd: 'ohasd.bin(6744) 720' topthread: 'crsd.bin(8362) 47'PROCESSES:name: 'oracle' pid: 9040 #procfdlimit: 65536 cpuusage: 0.19 privmem: 6040 shm: 121712 #fd: 33 #threads: 1 priority: 16 nice: 0...  ??CHM?????,???Oracle????:  http://docs.oracle.com/cd/E11882_01/rac.112/e16794/troubleshoot.htm#CWADD92242  Oracle® Clusterware Administration and Deployment Guide  11g Release 2 (11.2)  Part Number E16794-17  ?? My Oracle Support??:  Cluster Health Monitor (CHM) FAQ (Doc ID 1328466.1)

    Read the article

  • 11g R2 RAC Expert ????????? ~Blog??????~

    - by user763243
    ?????????????????5?????????????????????????????????????????????????????????????????????????????????????????????30??????????????6??????8?????????????????????????????????????????????????????????????????????????????????????????????????????????????????Blog?????????? ??????????????????????????????????????(500?)?RAC?????????????????????????????????????????????????????????? http://oracletech.jp/seminar/event/000557.html ??????????????RAC??????????????????????????????????????????????????????????????????Oracle ??????·??????????2???????????????????Grid Infrastructure 11g R2: ????&ASM??? ???????????????????Oracle ??????·???????????????????????????????????????????????5???????????? ??????Activate?????????????????????????????Activate?????????? Oracle ??????·????????????????????????????????????????????!

    Read the article

  • 11g R2 RAC Expert ????????? ~?????~

    - by user763243
    ?????????????????????????????(1?8??)???????????????4?????????????????????????????????????????????????????2?????????????????????????????????????????????????????????????????? ?????????????????????????????????????????????????????????????????????????????????????????????????????????????????? ????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????? ??????????RAC???????????????Grid Infrastructure??????????????????????????????????????????????????VM?????????????????????PC?????????????????????????????????????? ???????????????????????????????????????????????·?·????????(?)???????????????????????????????

    Read the article

  • ??????Sun ZFS Storage Appliance?????????????????·?????????

    - by Norihito Yachita
    ??????????????·????????Sun ZFS Storage 7320 Appliance??????????????????????????????????????IaaS(Infrastructure as a Service)???????????????????????????????????????????????????????? ???????????11?15?????????????4,000?????????????????????????????????????????????????????????·??????????????????????????????? ???????????????????????????????????????????????????????????????????????????????????????????????????InfiniBand???????????????????Sun ZFS Storage 7320 Appliance?????2011?5??????????6????????????????????????Sun ZFS Storage 7320 Appliance???????·???????

    Read the article

  • Sony Ericsson Windows driver problem

    - by alex
    I've installed Update Service and MediaGo for my Sony Ericsson phone but one of the drivers that was installed along with the software is causing problems in Windows 7 x64. Looking in the Event Log I see the following warning: Detected unrecognized USB driver (\Driver\seehcri) This is the driver corresponding to the Sony Ericsson seehcri Control Device. The failure to recognize the USB driver is causing problems with other services, namely the VMware USB Arbitration Service. It should normally start automatically but, due to the failure to recognize the seehcri USB driver, it fails with the following error: Error 31: A device attached to the system is not functioning. Disabling the driver has not helped at all. The VMWare service still refuses to start and I keep getting both warnings in the Event Log. I would like to remove the Sony Ericsson driver but unfortunately, that's not possible. Uninstalling the Sony Ericsson seehcri Control Device from Device Manager causes Windows to almost completely freeze up while trying to look for drivers for unrecognized hardware. Windows tries over and over again to locate and install drivers for an Unknown device, failing every time. Looking in Device Manager, it simply fills up with hundreds of unknown devices, also using up the CPU to almost 85% in the process. What should I do? How can I safely remove the driver without causing Windows to look for a new driver?

    Read the article

  • How do I get more information on a potential network freeloader?

    - by Dov
    I have a home network set up, complete with a relatively good password. I'm in Mac OS X 10.6 (Snow Leopard) and have been noticing, on occasion, a computer showing up in my Finder's Shared section, that is not one of my own (the "pe-xpjalle" box pictured below). He has a tendency to come and go. How can I figure out his MAC address or something, so I can block him? I checked my "Logs and Statistics" in the Airport Utility, and didn't see that computer under DHCP clients. I'd rather not change my password, since I have quite a few devices I'd have to update. Is there any other reason he's show up on my network besides having guessed my password? Update: I fixed the Dropbox URL above (how embarrassing, I'm new to Dropbox. Thanks for the heads up, Doug.) Update 2: I tried clicking on "Connect as..." just for the hell of it, and got the dialog below. Now I have even less an idea what's going on than before. I don't have Parallels of VMware running, just the following: Transmission, NetNewsWire, Mail, Things, Safari, iTunes, Photoshop, Pages, Yojimbo, Preferences, AppleScript Editor, Software Update, Airport Utility, and Terminal. I don't think any of those create a virtual network machine, right? And no VMware machine of mine has ever had a name resembling "pe-xpjalle". Update 3: I just changed my passwords on both my N- and G-only networks, and I'm still seeing this, so I highly doubt that it's someone who's figured out my password (twice now). I'm really stumped.

    Read the article

  • Windows XP SP3 client over NAT to a Windows 2008 R2 SP1 file server disconnection

    - by Patrick Pellegrino
    we just transferred a pilot group from our old(!!) Netware infrastructure to an Microsoft infrastructure. Since then, our users got problems accessing their files. They all experience disconnection from the mapped drives. The file server is access via a WAN connection by a firewall (Sonicwall) between both network and we do NAT. All clients have Windows XP SP3 and the file server is an Windows 2008 R2 SP1. On the file server I got many Event Id 2012. Many post over the Internet suggested a problem between the SMB protocol and NAT. We need a short term fix to continue to transfer users from Netware to Microsoft after what will work to remove the NATing. I found this MS KB http://support.microsoft.com/kb/2444558 that suggested a kind of workaround for Windows 7 clients but I can found anything for Windows XP. Anyone can help me with this ? We don't want to stop the project and do a network job before migrating. Regards. Update: Our few Windows 7 computers doesn't seem to have this issue.

    Read the article

  • Setup of HP ProCurve 2810-24G for iSCSI?

    - by 3molo
    Hi, I have a pair of ProCurve 2810-24G that I will use with a Dell Equallogic SAN and Vmware ESXi. Since ESXi does MPIO, I am a little uncertain on the configuration for links between the switches. Is a trunk the right way to go between the switches? I know that the ports for the SAN and the ESXi hosts should be untagged, so does that mean that I want tagged VLAN on the trunk ports? This is more or less the configuration: trunk 1-4 Trk1 Trunk snmp-server community "public" Unrestricted vlan 1 name "DEFAULT_VLAN" untagged 24,Trk1 ip address 10.180.3.1 255.255.255.0 no untagged 5-23 exit vlan 801 name "Storage" untagged 5-23 tagged Trk1 jumbo exit no fault-finder broadcast-storm stack commander "sanstack" spanning-tree spanning-tree Trk1 priority 4 spanning-tree force-version RSTP-operation The Equallogic PS4000 SAN has two controllers, with two network interfaces each. Dell recommends each controller to be connected to each of the switches. From vmware documentation, it seems creating one vmkernel per pNIC is recommended. With MPIO, this could allow for more than 1 Gbps throughput.

    Read the article

  • How to monitor process hogging CPU on a remote server

    - by sergeb
    I have a remotely hosted (virtual, VMware) dedicated server (Windows 2008 Server Web edition w/ SP1) that I can only connect to over Remote Desktop. Lately, a process hogs CPU for ~40 minutes most every day (at a random hour) and brings all web sites on the server down. While this is going on I also cannot connect using Remote Desktop to investigate on what is that process... Promptly after 40 min I can RD and the first thing I see on the Perf Monitor is that there was something topping the CPU at 100% and stops just before I'm able to RD... I'm aware of the beginning and end of this for I have monitors setup that email me up/down status of the web sites but I'm locked out while this is happening - can't RD to the server until it's over (and too late to see the Task Manager/Process Explorer picture). What is the best way/tool to setup on the server to continuously monitor all processes so when this happens I login and "replay" it to find the process causing this trouble? (I have no control over the virtual/VMware setup for it is hosted by a 3rd-party but I have most full control over my dedicated machine) Thanks in advance!

    Read the article

  • What configuration changes can I make to speed up extremely slow Windows VM's in ESXi 4.0.

    - by Shawn Anderson
    I've recently moved from VMWare Server to ESXi 4.0. Running on Dell T310. My VM's have been restored but they are running dog slow compared to VMWare Server. I loaded ESXi 4.0 using only default values. Where are some areas where I can tweak the performance? Even logging onto the VM's can be extremely sluggish. Trying to install software on any of them is a new experience in pain. Dell PowerEdge T310 Xeon X3460 2.80 GHz 32 GB RAM 1 HD (2 TB) I have 16 VM's on this server, but only six or so will be running during my testing. I keep an eye on the Resource Allocation and Performance tabs for the host and I never see CPU or RAM getting anywhere close to pegged. Events tab does show some notices for video RAM issues and some hints on Windows activation issues, but nothing that would point to the sort of sluggishness that I'm experiencing. 1 Windows Server 2008 R2 (64-bit) - 4 GB RAM 1 Windows 7 (32-bit) - 2 GB RAM 1 Vista (32-bit) - 1 GB RAM 3 XP (32-bit) - 1 GB RAM Over to you! Thanks - Shawn

    Read the article

  • How to set up ProxMox 1.9 on VPN?

    - by Gnudiff
    Disclaimer: I have only rudimentary knowledge of VPNs. I would love to learn about them properly, however, at the moment I really need to make stuff work on short notice. I am trying to set up a ProxMox virtualization platform in an existing network. The network currently consists of several servers which have VMWare free edition. There is some sort of VPN defined in switch. In order for VMWare management interface to be accessible, there needs to be ticked a checkbox in the network settings for VPN and entered the VPN id. I didn't notice any such configuration option during ProxMox installation, so my Proxmox VE on the same physical server, using same manual IP settings (ip/nm/gw), is not accessible. As I understand I should touch the Proxmox's underlying Debian config in /etc/network/interfaces, but I have no idea, what should I aim for: do I specify the settings for eth0, do I make a virtual interface? How to make it accessible for both ProxMox VE and underlying future VMs? I read the ProxMox installation guide, but unfortunately it presumes better understanding of VPNs than I have. A config template or similar would be appreciated. Thanks in advance.

    Read the article

  • Inter-VLAN Malicious Code Scanning

    - by Jackthedog
    I am trying to find an inbuilt solution on a Cisco Catayst 3750X Switch to scan all traffic routed from one VLAN to another for malicious code. The situation is that we currently have a development environment which is currently being redesigned to upgrade the network infrastructure to use the 3750X switches to manage server and workstation connectivity as well as inter-VLAN routing. We also have another system that is responsible for taking the builds created on the development environment and imaging various HDDs. Because these are two separate systems, we have a requirement in the workplace to anti-virus scan any data transferred between these systems. This is done by copying the data from the originating system to external USB HDD, scanning in a standalone workstation and then copying the data on to the receiving system. As you can imagine this is extremely tedious and impractical most of the time... (I don't make the rules). Anyway, with this redesign going on, we would like to join the imaging system to the network infrastructure of the development system, keeping separation by the use of VLANs and restricting traffic by using ACLs. As we still have the requirement to scan all traffic I would like to configure some sort of malicious code scanning when ever traffic is routed between these VLANs. I am aware I could install a separate in-line IPS/IDS device, however both systems will be using multiple ports on the switch (obviously), and we won't be able to put a device on each port. I would would prefer not to add additional hardware if the 3750x switch is capable of doing the job. Is anyone aware of any Cisco solution that I could use here, that ideally can be incorporated into the 3750x switch? Thanks in advance.

    Read the article

  • copying an lvm partition to a smaller disk, and renaming volume groups.

    - by dlamblin
    I was trying to shrink a vmdk (VMWare disk image) file to be as small as possible, and found two recommendations. The first is to cat /dev/zero into the fs then delete it, and run VMWare tools' shrink. This works okay. The second is to copy everything into a new vmdk. I went the second route. I did not use dd because I actaully want to use as few blocks as possible, instead of having a block-by-clok copy. Any unlinked files will still have blocks that aren't zeroed out. Secondly the centos image was mostly lvm, except for the boot partition, and my target was going to be 4gb instead of 8gb. I did use dd for the first 40mb to get the boot blocks and partition copied. I then used parted to create an identical primary boot, and smaller primary lvm. Then I used pvcreate on that device sdb2, vgcreate, and lvcreate to create a root and swap. I used mkfs.ext3fs on the root partition and then rsync -av / /2root excluding /proc /sys /2root /dev. So far everything went fine. My problem is that: The result is 2.7 GB while the source was 2.1 GB. This is weird to me. The second vgroup is called VolGroup01, while the original was called VolGroup00. How can I rename the VolGroup01 to VolGroup00 and swap it out after all this?

    Read the article

  • Monitoring / metric collection for system collectives that change a lot in time (a.k.a. cloud)

    - by Florin Andrei
    When your server fleet doesn't change a lot in time, like when you're using bare-metal hosting, classic monitoring and metric collection solutions (Nagios, Munin) work well. But if the number of systems varies a lot in time, and may in fact vary rapidly, classic software is more difficult to setup and use. E.g., trying to make Nagios (monitoring) keep up with a rapidly evolving cloud infrastructure can be cumbersome. Same for Munin (metric collection). It's not just the configuration, but the way the information is conveyed to the user, or displayed, is inadequate for the cloud. What are some possible alternatives that work well with the cloud? The goals are to collect and display metrics (analog to Munin), and generate alerts when certain metrics go out of bounds or when certain services are unavailable (analog to Nagios), and do everything in a cloud-friendly manner. Some cloud providers offer monitoring / metric collection as services, but not always, and if you use more than one provider you don't want to become too dependent of just one vendor. So provider-independent solutions are required. EDIT: I am asking this question in a general fashion - not limited to any given cloud infrastructure (like OpenStack), but in the general case of using arbitrary cloud providers.

    Read the article

  • Desktop virtualization

    - by gurpal2000
    Is there currently a proper Type 1 "desktop" hypervisor? Either free or not? This is just for tinkering around at home on some beefy Phenom machines. Basically i want to be able to run say 2 OSs on the same PC but without loading windows or a heavy flavour of linux and then use a hotkey to switch between them. I should get full performance out of them. So do i need something better than vmware workstation and/or virtualbox. I think these are "Type 2"? I already run VMWare w/s and VBox but is there a more performant solution? I saw a YouTube video from Citrix where a laptop was running XP and Vista. With the touch of a hot key they could switch between them. There was no visible underlying OS (there might be a hypervisor)? I have access to Citrix XenDesktop 3 enterprise edition evaluation. I realise this isn't for desktops but can i achieve my goal (geekiness) ? If i use the free XenServer 5.5.0 how do my client PCs access windows/linux/whatever from the xenserver? Is it via a thin client RDP type application? If so if there one for both windows and linux? Also if i do use XenServer can i use USB in either direction? What is Citrix receiver can i use that for (3) ? If so, is there some hotkey i can configure? whatever client is used to access the server software (whether it be on a different server or local) can i get full opengl/directx acceleration? what about Xen? i tried the Xen LiveCD but no clue as how to configure it. As you can see much confusion. Any help/pointers welcome. Cheers.

    Read the article

  • Why Virtual Box won't give me option to create 64 bits guests?

    - by Eduardo Born
    My host is x64 bits Windows 8.1. I downloaded the latest Virtual Box (4.3) and I'm trying to create a VM with a 64 bits Ubuntu OS (ubuntu-12.04.3-desktop-amd64). When I go to New VM wizard, it doesn't give me option to select "Ubuntu (x64)" as I have seen in other people's screenshots, only just "Ubuntu". As a result, the ISO can't boot. I tried in another PC and Virtual Box gives the x64 variants to most listed OS... Control Panel shows x64 OS, x64 processor. My host laptop is a Sony Vaio VPCZ22UGX/N, Intel® Core™ i7-2640M processor. CPUz shows Vx-t is available on my processor, of course. Here is what I tried so far: I enabled IO APIC as required in the docs. I have virtualization enabled in the BIOS. It works fine in VMware. Check that Hyper-V is not running or even installed on my Windows. Same for VMware. I also tried running the command: VBoxManage modifyvm [vmname] --longmode on for that VM, but no change.. I think the issue is really that I can't select x64 variant of the Ubuntu OS for that VM. Other people seem to indicate that's a requirement, but I don't get that option for some reason. I spent a lot of time and can't find what's wrong... Anyone knows what could be missing here? Thank you very much!! Eduardo

    Read the article

  • AWS document on number of databases allowed on an Amazon RDS instance

    - by user35042
    At the Amazon RDS FAQ there is the question "What is a database instance (DB Instance)?". The entire answer (as of mid-June 2012) is: You can think of a DB Instance as a database environment in the cloud with the compute and storage resources you specify. You can create and delete DB Instances, define/refine infrastructure attributes of your DB Instance(s), and control access and security via the AWS Management Console, Amazon RDS APIs, and Command Line Tools. Multiple MySQL databases or SQL Server databases (up to 30) or Oracle database schemas can be created on a given DB Instance. The last part of that quote, "Multiple MySQL databases or SQL Server databases (up to 30) Oracle database schemas" I interpret to mean that you can have an "unlimited" number of databases on an RDS MySQL or Oracle instance but only 30 databases on an MS SQL Server instance ("unlimited" meaning not limited by the RDS infrastructure itself). This was asked in the Stackoverflow question Does Amazon RDS support multiple databases per instance?. The answer quoted an older version of the FAQ. What I am looking for is an Amazon document that clarifies this question, or else someone who has experience using Amazon RDS who can attest what the situation actually is.

    Read the article

  • Ping server NETBIOS name returns wrong IP and "Destination host unreachable"

    - by music2myear
    Problem server is Windows 2008 R2 VM running on VMWare ESXi 4 host. Single network adapter manually assigned single IP address (192.168.1.11). When I ping the server from any other network computer, it returns 192.168.1.124 and "Destination host unreachable". Yesterday I found a second network adapter assigned to this server with an IP of 169.254... indicating it had no real valid IP. Using the MAC addresses I determined which adapter was not needed/not wanted, and removed it using VMWare systems. This is the network Printer Server and, understandably, nothing is printing right now. I've looked at the solutions here Why was my ping answered by a different IP address than the one pinged? and they aren't applicable to my situation for the following reasons: Output of arp -a on another computer returns the correct IP address (.1.11) assigned to the correct MAC address, the incorrect IP .1.124 is not listed, and the MAC of the network adapter I removed yesterday is not listed at all. I checked out the Microsoft KB article which listed pretty much my exact symptoms ( http://support.microsoft.com/kb/981953 ) and it says to check binding orders and look for hidden adapters. But there are no hidden adapters, and there is only one Network Adapter listed in the Binding Order list. Essentially, I can communicate from the server TO any other network device, but I cannot communicate from any other network device TO the server. Help! UPDATE: Solution found, see this solution for the details.

    Read the article

  • What is the difference between the Linux and Linux LVM partition type?

    - by ujjain
    Fdisk shows multiple partition types. What is the difference between choosing 83) Linux and 8e) Linux LVM? Choosing 83) Linux also works fine for using LVM, even creating a physical volume on /dev/sdb without a partition table works. Does picking a partition type in fdisk really matter? What is the difference in picking Linux or Linux LVM as partition type? [root@tst-01 ~]# fdisk /dev/sdb WARNING: DOS-compatible mode is deprecated. It's strongly recommended to switch off the mode (command 'c') and change display units to sectors (command 'u'). Command (m for help): l 0 Empty 24 NEC DOS 81 Minix / old Lin bf Solaris 1 FAT12 39 Plan 9 82 Linux swap / So c1 DRDOS/sec (FAT- 2 XENIX root 3c PartitionMagic 83 Linux c4 DRDOS/sec (FAT- 3 XENIX usr 40 Venix 80286 84 OS/2 hidden C: c6 DRDOS/sec (FAT- 4 FAT16 <32M 41 PPC PReP Boot 85 Linux extended c7 Syrinx 5 Extended 42 SFS 86 NTFS volume set da Non-FS data 6 FAT16 4d QNX4.x 87 NTFS volume set db CP/M / CTOS / . 7 HPFS/NTFS 4e QNX4.x 2nd part 88 Linux plaintext de Dell Utility 8 AIX 4f QNX4.x 3rd part 8e Linux LVM df BootIt 9 AIX bootable 50 OnTrack DM 93 Amoeba e1 DOS access a OS/2 Boot Manag 51 OnTrack DM6 Aux 94 Amoeba BBT e3 DOS R/O b W95 FAT32 52 CP/M 9f BSD/OS e4 SpeedStor c W95 FAT32 (LBA) 53 OnTrack DM6 Aux a0 IBM Thinkpad hi eb BeOS fs e W95 FAT16 (LBA) 54 OnTrackDM6 a5 FreeBSD ee GPT f W95 Ext'd (LBA) 55 EZ-Drive a6 OpenBSD ef EFI (FAT-12/16/ 10 OPUS 56 Golden Bow a7 NeXTSTEP f0 Linux/PA-RISC b 11 Hidden FAT12 5c Priam Edisk a8 Darwin UFS f1 SpeedStor 12 Compaq diagnost 61 SpeedStor a9 NetBSD f4 SpeedStor 14 Hidden FAT16 <3 63 GNU HURD or Sys ab Darwin boot f2 DOS secondary 16 Hidden FAT16 64 Novell Netware af HFS / HFS+ fb VMware VMFS 17 Hidden HPFS/NTF 65 Novell Netware b7 BSDI fs fc VMware VMKCORE 18 AST SmartSleep 70 DiskSecure Mult b8 BSDI swap fd Linux raid auto 1b Hidden W95 FAT3 75 PC/IX bb Boot Wizard hid fe LANstep 1c Hidden W95 FAT3 80 Old Minix be Solaris boot ff BBT 1e Hidden W95 FAT1 Command (m for help):

    Read the article

  • How to find the cause of locked user account in Windows AD domain

    - by Stephane
    After a recent incident with Outlook, I was wondering how I would most efficiently resolve the following problem: Assume a fairly typical small to medium sized AD infrastructure: several DCs, a number of internal servers and windows clients, several services using AD and LDAP for user authentication from within the DMZ (SMTP relay, VPN, Citrix, etc.) and several internal services all relying on AD for authentication (Exchange, SQL server, file and print servers, terminal services servers). You have full access to all systems but they are a bit too numerous (counting the clients) to check individually. Now assume that, for some unknown reason, one (or more) user account gets locked out due to password lockout policy every few minutes. What would be the best way to find the service/machine responsible for this ? Assuming the infrastructure is pure, standard Windows with no additional management tool and few changes from default is there any way the process of finding the cause of such lockout could be accelerated or improved ? What could be done to improve the resilient of the system against such an account lockout DOS ? Disabling account lockout is an obvious answer but then you run into the issue of users having way to easily exploitable passwords, even with complexity enforced.

    Read the article

  • KVM and JBoss Java Application Server

    - by Jason
    We have a large Xen deployment running on both RHEL and CentOS and have recently started looking at KVM since this is where it looks like the future of VM's are on Linux. We can load the server and get everything running without an issue. However when we load up a new one with JBoss (4.2 Community edition, Sun JDK 6) and load a large EAR the server goes a little crazy. The %sy will jump to 80-99% and just hang for large periods of time we see a similar jump in %us on the host machine. We though at first this might be I/O as it seems to happen at start of JBoss but then would "cool down" after everything got loaded. We did some tests by extracting some large tar.gz files and using jar -xvf on the ear but could not re-create. Then we starting thinking this might be some type of memory access issues. We loaded a c-program that would generate a lot of memory activity and sure enough we saw the spikes again. Not as high mind you but we did see it jump. We then wrote a small java program to do the same thing and sure enough we saw it jump again. Any thoughts on what might be causing this? Is this just the way KVM works? As a side note we do NOT see this behavior on any other setup. Xen, VMWare and/or native iron. The system does seem a bit slower than our Xen / VMware ones.

    Read the article

  • Using a Level 2 switch as a core switch

    - by imtech
    I have a small user base of about 20 people on at a time and spiking up to about 80 people during peak times. Most people (80+%) are connected over our Aruba managed wireless system. We have a Windows Domain. We have 3 24-Port switches all connecting back to a central 48-port switch where additional access ports, firewall, servers, and wireless controller all centrally connect back to. It's a flat network with dumb switches. I'm in the process of upgrading our infrastructure. Cisco pricing for switches is pretty high for us so I've been looking at HP Procurves which seem to be within our budget range. I want to eventually make use of 802.1x, SNMP, QoS for possible VOIP upgrades, VLAN to separate guest VLAN from authenticated users, and other more advanced features. PoE would be nice but that's probably too expensive for us. I was thinking of having our core switch be a Procurve 2610 and the rest of our switches that centrally connect to it be Procurve 2510s. A true and full blown level 3 switch is way out of our price range but a 2610 seems to be good enough for us. The 2610 does static routing which ought to be good enough for us but I'm in unfamiliar territory so I'm looking for any gotchas. Also, should all the switches be 2610s or just the core switch? Do I even need the 2610, can I just go with all 2510s? I'm new to VLANs as well so I'm not sure what it is I need but I would like an affordable infrastructure that won't need replacing 2-3 years down the line because I choose a product that was lacking.

    Read the article

  • Install Windows 7 from ISO image

    - by Albert
    Hi, I have an ISO file of the Windows 7 DVD and I want to install it on my PC which currently only runs Linux. I don't have any DVD drive. I have some unpartitioned space on one disk where I want to install it in. When I am doing this for Linux, I usually just create the partitions from the running system, format them, mount them, copy files over, chroot into it, setup the stuff and I can boot into it (or I use some of the uncountable available scripts which do exactly that automatically). However, I have no idea how to do the same thing with Windows. So far, I tried with VMware, i.e. I gave it direct full access to the disk where I want to install it in, installed it there, then tried to boot natively into it. The Windows logo showed up but after maybe 3 seconds or so, it crashes. Safe mode also crashes. I already expected that this probably would exactly behave the way it does right now because I have heard that Windows is quite sensible about hardware changes (i.e. the VMware hardware and the real hardware). However, how can I fix it now that it works? Or I could also just delete it again and try just over. But how exactly? I also searched for ways to boot directly into an ISO file. There seem to be ways to do that via GRUB (and maybe some additional boot loader), although quite complicated. I already tried one method (GRUB: map ...iso (hdX)), however, that didn't worked. Also, even if it does work, I will get into trouble when I boot into the newly installed Windows and it requests for the DVD (because it does that at the first boot into the new system). Seems all quite complicated. Isn't there some easy way like I would do it for Linux? Or what would be the easiest way to get what I want?

    Read the article

  • Better logging for cronjob output using /usr/bin/logger

    - by Stefan Lasiewski
    I am looking for a better way to log cronjobs. Most cronjobs tend to spam email or the console, get ignored, or create yet another logfile. In this case, I have a Nagios NSCA script which sends data to a central Nagios sever. This send_nsca script also prints a single status line to STDOUT, indicating success or failure. 0 * * * * root /usr/local/nagios/sbin/nsca_check_disk This emails the following message to root@localhost, which is then forwarded to my team of sysadmins. Spam. forwarded nsca_check_disk: 1 data packet(s) sent to host successfully. I'm looking for a log method which: Doesn't spam the messages to email or the console Don't create yet another krufty logfile which requires cleanup months or years later. Capture the log information somewhere, so it can be viewed later if desired. Works on most unixes Fits into an existing log infrastructure. Uses common syslog conventions like 'facility' Some of these are third party scripts, and don't always do logging internally. UPDATE 2010-04-30 In the process of writing this question, I think I have answered myself. So I'll answer myself "Jeopardy-style". Is there any problem with this method? The following will send any Cron output to /usr/bin//logger, which will send to syslog, with a 'tag' of 'nsca_check_disk'. Syslog handles it from there. My systems (CentOS and FreeBSD) already handle log rotation. */5 * * * * root /usr/local/nagios/sbin/nsca_check_disk 2>&1 |/usr/bin/logger -t nsca_check_disk /var/log/messages now has one additional message which says this: Apr 29, 17:40:00 192.168.6.19 nsca_check_disk: 1 data packet(s) sent to host successfully. I like /usr/bin/logger , because it works well with an existing syslog configuration and infrastructure, and is included with most Unix distros. Most *nix distributions already do logrotation, and do it well.

    Read the article

  • MacBook Pro and Backtrack 5R1 Configuration

    - by user119346
    I have a Macbook pro Quad core (2.2/8gb ram/750gb hdd). I have went through tons of forums on the Internet, but none of them seemed to be updated for the current Backtrack 5R1, or the question of getting it to correctly work on the MBP. Can anyone help? I don’t have a USB Dongle, and I want to be able to use the internal airport extreme wireless of the MBP to use BT 5R1. I have downloaded Backtrack 5R1 onto VMWare Fusion, and got it up and running, but to no avail. It keeps recognizing my card as a Ethernet connection. Kismac wont recognize the card either. So what I am asking for is this: The proper “download method.” for Backtrack 5R1 to my MacBook Pro. (YES I AM WILLING TO RE-DOWNLOAD BT 5R1). The Complete process from start to finish, UP TO DATE, from someone who has done this using an MBP Running Lion OSX. The proper tweaks, settings, or commands to get my airport extreme wireless card to work (it is BROADCOM 4331 I think). The wireless connection I need to use the tools on both Backtrack 5R1 and Kismac. I mainly need to test WEP cracking on my network for security. The difference between running BT 5R1 on VMWARE Fusion and running from downloading it directly to the MBP, if there is, How to download it directly to the MBP?

    Read the article

< Previous Page | 86 87 88 89 90 91 92 93 94 95 96 97  | Next Page >