Search Results

Search found 2602 results on 105 pages for 'dell vostro'.

Page 96/105 | < Previous Page | 92 93 94 95 96 97 98 99 100 101 102 103  | Next Page >

  • Microsoft Access: computer freezes when user tries to update record

    - by CarlF
    A colleague and I have developed an Access 2003 database which is used throughout our department. Currently about four dozen people do data entry using one of two very similar forms. If 47 of us use them, they work perfectly. If Mr. 48 clicks the "Save" button, Windows XP freezes and a hard reset is needed. The problem has to be on his specific computer (Dell latitude D630) and not in the code because this problem only affects him. Complicating the matter: I don't work for IS, and this project is not supported by IS. If I'm going to get our tech support to fix the problem I had better be able to explain exactly what to do and how to do it, because they aren't going to invest any resources. I don't even have admin rights on the computer (and neither does its regular user). I've asked him to bring his laptop the next time he visits my building. (Just to make matters worse, he doesn't usually work in the same location as me or the other developer.) Any suggestions on debugging the problem? My first try will be to uninstall and reinstall Office, which I can do using corporate utilities without being admin. Note: yes, those are old versions of Office and Windows. We expect to upgrade later this year.

    Read the article

  • Can't create new Volume on Unallocated Space

    - by natediggs
    I installed Windows Server 2008 R2 on a Dell server that has one volume that is a 6 TB RAID 5 array. I created a 120GB install volume and I'm now trying to create a 5 TB data volume. For what ever reason Windows will not allow me to create a new volume out of all of the unalocated space. Windows will allow me to create a new volume out of one 2TB block of unallocated space but not the remaining 3.5 TB block. Tried to post a screen shot but I was blocked. If I right click on the 1949.85 GB block of space there is the option to create a new volume. If I click on the 3539.5 GB block of space that option is grayed out. If I go into diskpart and try to create a new partition, diskpart says that there is only 1949GBs free on the volume. I know this process works because I did the exact same thing on another server that we have that is the exact same hardware configuration on which I used the exact same Server 2008 R2 install image. Any help would be greatly appreciated. Nate

    Read the article

  • 2560 x 1600 screen resolution not available when a second monitor is attached.

    - by sgmoore
    I am running Windows 7 (64-bit edition) and have a 30" Dell 3007WFP monitor which runs at a screen resolution of 2560 x 1600. This works perfectly until I try to connect a second monitor, and then the screen resolution on the main monitor immediately drops to 1280x800 and I can't change it back up to the correct resolution until I disconnect the second monitor. The graphics card is a Nvidia Quadro FX 370. This has a dual link DVI connector (to which the 30" is connected) and a single link DVI connector. The second monitor can run at 1920x1080 and is connected using a VGA to DVI connector. Note, it does not seem to matter whether the second monitor is running at 1920x1080 or even at 800x600. Windows reports Total Available Graphics Memory: 3839MB Dedicated Video Memory: 256MB System Video Memory: 0MB Shared System Memory: 3583MB Does anyone know if this a limitation with the video card, memory, drivers, connectors or something else? If this is a limitation with the video card, can anyone recommend a PCI Express 16 card that would support at least this setup, but preferably support two 30" monitors both running 2560 x 1600. (I'm not into gaming etc, so it doesn't need to be very powerful)

    Read the article

  • Laptop Most Likely to Have Good Driver Support

    - by ShabbyDoo
    Through numerous bad experiences, I have learned that the most likely cause of laptop "failure" is the lack of updated drivers for new operating systems. As an example, I have a perfectly good Thinkpad T42 at home which runs Windows 7 just fine for my purposes except that no compatible ATI video drivers are available, and the generic drivers have flicker effects. I recently saw an ASUS laptop which looked quite nice except that I would be beholden to them to release ATI video driver updates customized for it. And, I can't trust them to do that for more than six months. What laptops (manufacturer/line) should I consider so that I could expect at least a couple years of frequent updates? I plan on running Windows 7 and installing whatever successor comes out. I like Intel components (especially WiFi) because I can install their drivers directly from them, and they have a long history of providing updates for years after shipping a particular component. More generally, components from companies which are likely to update drivers frequently are good as long as I can install the component manufacturer-provided drivers without laptop-specific customization (like the ATI drivers). Also, if a component can be replaced easily, I am less concerned. For example, Dell stopped pumping out updated drivers for one of its mini-PCI WiFi cards. The solution was to buy an Intel replacement on eBay for $12! That's fine. I can deal with that. So, what laptops should I consider so that I'm not likely to be stuck between a rock and a hard place?

    Read the article

  • Cant kill process on Windows Server 2008!! - Thread in Wait:Executive State

    - by adrian
    I hope someone can help me with our issue we are having. We have a major issue with a process that we can not kill and the only way to get rid of the process is to reboot the machine. I have tried killing it from the normal task manager but no joy. I have tried killing it using the taskkill /F command from a command prompt and no joy. The command reports as sucessful but the process remains. I have tried to start task manager with system rights by calling "psexec -s -i -d taskmgr" and attempting to kill the process but no joy I have tried killing it from Process Explorer but again the process remains. I have tried creating a scheduled task that runs under the SYSTEM name to kill the task but that also does not kill it : schtasks /create /ru system /sc once /st 13:16 /tn test1 /tr "taskkill /F /PID 1576" /it Nothing I do will kill this process. Even logging off and logging back on will not kill this process. Using Process Explorer I notice that there is on stubborn thread that is in the Wait:Executive state. I have tried to kill this thread using Process Explorer but again no joy. We are using Windows Server 2008 R2 64-Bit. The server is brand new and windows is freshly installed. Now heres the thing. We have brought two identical servers from Dell with the same specs and the same OS installed and I can not replicate this issue on the other server. Only on this server, under certain circumstances does this server process hang and can not be restarted! I have also changed the compatability mode by setting it the process to "Windows 2003" but this has not helped. I have noticed in Process Explorer that DEP is turned on but im not sure this has got any bearing on the issue ot not. Please, can someone help??

    Read the article

  • Prevent Windows from resizing all the apps on the desktop when switching monitors

    - by Greg Hewgill
    Short version: When moving my laptop and sleeping between using different monitors, all my open windows are crammed into the upper left corner as if they tried to fit on the laptop internal screen resolution. I plug in and switch to the external monitor before unlocking my session. Is there a way to prevent this automatic resizing? Longer version: I have a laptop that I move between two locations. I have one docking station, and the same kind of monitor configured for 1600x1200, in both locations. The internal laptop screen is awful so I don't use it. Location A: Docking station, monitor connected via DVI. Location B: No docking station, external monitor connected via VGA cable. In this location I have the laptop lid open for keyboard access but I don't use the laptop screen. When moving from Location A to Location B, the laptop wakes up from sleep, displaying the screen on the internal monitor. I switch to the external monitor display (using Fn+F8 on this laptop), and only after that do I unlock my session with my password. However, Windows has crammed all my nicely arranged windows into the upper left corner as if it were trying to fit them all on the laptop internal screen resolution. When moving from Location B to Location A, I have the laptop lid closed when using the docking station so Windows apparently concludes the screen resolution is 1600x1200 and doesn't resize any windows. The laptop is a Dell Latitude running Windows 7 Professional.

    Read the article

  • Server freezes while installing Redhat Enterprise Linux Server 6

    - by eisaacson
    We've tried both the first options Install or upgrade an existing system Install system with basic video driver When trying option #1, it gets to a screen that has a solid cursor about halfway down, then freezes. When trying option #2, it freezes at the point where it says: Waiting for hardware to initialize... Of course, we bought the unsupported version and haven't found anything to help us so far. Here are the specs to the server in the original post: ASUS P8Z68-M Pro LGA 1155 Intel Z68 HDMI SATA 6Gb/s USB 3.0 Micro ATX Intel Motherboard with UEFI BIOS RAIDMAX Reiter ATX-305WBP Black Steel / Plastic ATX Mid Tower Computer Case 450W Power Supply Intel Core i7-2600 Sandy Bridge 3.4GHz (3.8GHz Turbo Boost) LGA 1155 95W Quad-Core Desktop Processor Intel HD Graphics 2000 BX80623I72600 16GB Ram OCZ Agility 3 SSD 120GB From some of the posts out there could the UEFI Bios or the Sandy Bridge processor be a culprit here? We just tried the DVD on a different computer and it got past that point with ease. It's a standard Dell build compared to our custom machine. Could it be having difficulty recognizing drivers? How do we get past that?

    Read the article

  • How do I keep a bridge enabled on a bonded interface?

    - by jlawer
    I'm working on setting up a pair of CentOS 6.3 servers that will run a couple of KVM vms and have come across a problem setting up a bridge on a bond. I am using Mode 4 (802.3ad) bonding on a pair of stacked Dell Powerconnect 5524 switches connecting to R320 servers. There are 2 links (1 to each switch) that form a Link Aggregation Group (802.3ad / LACP bonding). On top of the bond I have VLAN Tagging. I've verified this is a problem on multiple other bonding modes so it isn't just a mode 4 issue. I am testing what happens when 1 link is dropped (ie switch dies, cable breaks, etc). If I don't have a bridge (for KVM), everything works fine, failover happens as expected. If I have the bridge enabled, it works fine until failover (unplugging a cable). When failover happens /var/log/messages shows the slave link going down, followed within a second by: kernel: br1: port 1(bond0.8) entering disabled state The thing is /proc/net/bonding/bond0 shows the link is up as expected (simply with only 1 slave instead of 2). If I plug the cable back in it recovers and brings the bridge back to an enabled state. I actually have tested this while a ping is occuring and if the timing is right a packet will actually leave the system after the link is lost, but before the disabled message occurs. This disabled state I assumed was STP, but I have disabled STP on the bridge configuration and this issue still occurs. brctl showstp br1 still shows the link as disabled when it is running without a slave. I also switched between the nics in the server (I have 2x Broadcom & 4x intel). It doesn't matter which configuration I have. Does anyone know of a way to force the bridge to stay enabled or why its detecting the bond as disabled, when it isn't?

    Read the article

  • How to configure a Linux kernel based on the modules currently in use?

    - by Carla
    Hello, I'm willing to build a minimal kernel with only the needed things for my machine; so I started by compiling the kernel from the ground up, using the default configuration and adding things that I know for sure I have (i.e.: Ethernet card, WiFi card, ...). But there are several other things not so easy to know about (i.e.: the watchdog timer) so I came across AutoKernConf which supposedly detects the hardware of the machine and generates a kernel configuration file with the settings for the found devices. The problem is it contained several settings repeated and even some which I don't have (I'm using a Dell laptop and one of the things it "found" was something of a Toshiba one). So I ended up building a kernel with the configuration that came out of the make allmodconfig command, which is a kernel with most of the things compiled as modules. Booting into that kernel and running lsmod I can see all of the kernel modules in use (the ones really needed) and I would like to know if there is a tool or some way for me to parse that list and convert it to the corresponding kernel configuration file. Or how to map each one with the appropriate options in the kernel so that I can manually set them. Thank you very much for your time.

    Read the article

  • Windows 7 boots to black screen with blinking cursor

    - by murgatroid99
    I have an Alienware M17x that dual boots into Ubuntu 11.04 and Windows 7 Home Premium. Currently, the computer starts at the GRUB loader and will boot into Ubuntu, but if I try to boot into Windows, I immediately get a black screen with a blinking cursor in the upper left corner. The output of fdisk -l is Device Boot Start End Blocks Id System /dev/dm-0p1 1 5 40131 de Dell Utility Partition 1 does not start on physical sector boundary. /dev/dm-0p2 6 1918 15360000 7 HPFS/NTFS Partition 2 does not start on physical sector boundary. /dev/dm-0p3 * 1918 64772 504878877+ 7 HPFS/NTFS Partition 3 does not start on physical sector boundary. /dev/dm-0p4 64772 77827 104858625 5 Extended Partition 4 does not start on physical sector boundary. /dev/dm-0p5 64772 67204 19531008 83 Linux /dev/dm-0p6 67204 74498 58593536 83 Linux /dev/dm-0p7 74498 77577 24731648 83 Linux /dev/dm-0p8 77578 77827 2000128 82 Linux swap / Solaris I have used the Windows rescue CD, and run the automatic error fixer until it finds no errors. I have run chkdsk /R on both the main Windows 7 (/dev/dm-0p3) partition and the recovery partition (/dev/dm-0p2). I set the main Windows 7 partition to be active. I also tried running in the recovery console the commands bootrec /fixmbr bootrec /fixboot bootrec /rebuildbcd None of these helped and the last set of commands deletes grub, which I then have to reinstall from Ubuntu. I think the last thing I did in windows before this started was install the newest ATI driver for my video card. This would suggest using system restore, and I actually had a restore point earlier (after the problem started), but after whatever I did that restore point does not appear in the list on the recovery disk any more, so I cannot do a system restore. Is there anything else I can try to make Windows boot properly again? Edit: Running the suggested commands bootsect /nt60 c: bcdboot c:\windows /s c: was also ineffective.

    Read the article

  • PowerShell 3.0 x64 bit broken after installing KB2506143

    - by Dave Parker
    I have searched using all kinds of variations on relevant terms and I cannot find a single other instance of someone else having this excact same problem, so I am hoping someone here may have a clue. Problem I installed Windows Management Framework 3.0 (KB2506143) by downloading and running Windows6.1-KB2506143-x64.msu from Microsoft.com. Once completed I rebooted my machine as requested. After rebooting and logging in, I try to run the 64-bit PowerShell command shell and it comes up for a second then goes away. The 32-bit shell seems to work fine, it is just the 64-bit one that fails. Looking in the Fusion logs, I found: *** Assembly Binder Log Entry (10/4/2012 @ 1:51:48 PM) *** The operation failed. Bind result: hr = 0x80070002. The system cannot find the file specified. Assembly manager loaded from: C:\Windows\Microsoft.NET\Framework64\v2.0.50727\mscorwks.dll Running under executable C:\WINDOWS\system32\WindowsPowerShell\v1.0\powershell.exe --- A detailed error log follows. === Pre-bind state information === LOG: User = ********\***** LOG: DisplayName = Microsoft.PowerShell.ConsoleHost, Version=3.0.0.0, Culture=neutral, PublicKeyToken=31bf3856ad364e35, processorArchitecture=MSIL <remainder omitted> GacUtil reveals that there is a Microsoft.PowerShell.ConsoleHost, Version=1.0.0.0, but not 3.0.0.0. I tried uninstalling KB2506143 (which removed MSVCRT90.dll and caused Windows Live Messenger to fail on load after rebooting again, so I ran a repair in stall on Windows Live Essentials and that fixed the Messenger problem) and then re-installing it, but nothing changed. If it helps, here are what I think may be the relevant parts of my hardware/software environment. Environment Dell Latitude E6510, 8GB RAM Windows 7 Professional 64-bit with SP1 Visual Studio 2010 Professional installed (includes .NET 4.0) Visual Studio 2012 Professional installed Microsoft Forefront Client Security Any clues out there? Thanks, Dave

    Read the article

  • Proxmox drbd configuration split brain [on hold]

    - by AudioDan
    I am planning a proxmox HA configuration with two Dell R710 machines (dual 6 core processors in each) with enterprise level drive raid arrays. I would be using DRBD with a quorum disk on a third machine. I would dedicate two 1GB nics on each server to the DRBD communications. We would have approximately 12 to 14 Virtual Machines running on this pair of servers. The proxmox manual recommends creating two DRBD resources - one for the Virtual Machines that normally run on ServerA and one for the Virtual Machines that normally run on ServerB. This is because of the Primary/Primary state in which this configuration runs. If both servers have VMs talking to the same DRBD resource and a split brain situation occurs, there is potential for data corruption that must be resolved. While I understand it would take more effort to create new virtual machines, can anybody foresee any potential problems with running a separate DRBD resource for each VM instead? Does anyone have experience running a setup that way and has it worked well? It seems to me that would allow more flexibility in moving machines back and forth.

    Read the article

  • After upgrading to 2008 R2 Enterprise and installing more RAM, Windows can only see 4.00 GB

    - by Tom Crane
    (I have also posted this on technet but I'm running out of ideas) I've upgraded from Windows Server 2008 R2 Standard to Enterprise in order to make use of more RAM. The server previously had 32GB of RAM. The upgrade from Standard to Enterprise, using DISM, seemed to go OK, so I powered down and installed the RAM. This a Dell Poweredge T710, I was taking it from 32GB to 72GB. The BIOS recognised the RAM, although I needed to change from "Advanced ECC" to "Optimizer" mode for it to use all of it. After rebooting, windows can see the RAM but in the system panel will display: Installed memory (RAM): 72.0 GB (4.00 GB usable) In the resource monitor, the remainder of the RAM is showing as reserved for hardware. I've tried various RAM configurations, including reverting it to the same chips and same configuration as before the upgrade, but always just 4.00 GB is showing up as usable. Following some threads on these forums I've gone into msconfig and set the maximum memory "by hand" but that doesn't fix the problem. BIOS doesn't seem to have anything that looks like memory remapping which is another suggestion that has come up. How do I make this RAM available to Windows? It was available before the upgrade, because I could use the full 32GB RAM the server had to start with. A screenshot (this is after reverting to the original RAM configuration) http://screencast.com/t/5FuzevdNb I don't know if it's related, but my remote desktop configuration has also disappeared: screencast.com/t/mYedomeQWS (the bottom half of this dialog should allow me to configure Remote Desktop, it was working before the upgrade but now it isn't).

    Read the article

  • Ubuntu and Windows and Separate HDs, oh my!

    - by LuxuryMode
    Need some major help. Running a Dell XPS/Dimension 630i. It came with "SATA 2 RAID 0 With Dual 500GB Hard Drives." I have installed a new, third non-raided drive and installed Ubuntu on it. So now I have Windows on the original hard drive and Ubuntu Linux on the new HD. When I get to the boot menu where I can select an OS, if I select windows I get an error: "No such drive, no such disk." Also, strangely in the first place, in order to even get to the bootloader menu I have had to disable ALL ports under the RAID config. Unless I do this, I will just get to a never-ending blinking cursor. I have tried every conceivable CMOS config and nothing else works. Tried setting port 3 (the new HD w/ Ubuntu) to first hard disk boot priority. Tried disabling all other ports and enabling the Ubuntu HD port and vice versa. Here's a pic of the error I get when I try to boot to Windows: http://imgur.com/TJ1mS. Also, please note that I can actually access all files from the raided Windows drive through Ubuntu. (Someone suggested just reinstalling windows from installation CD. Agree?)

    Read the article

  • Network connection keeps dropping - bad hardware?

    - by Bill Sambrone
    Hello all, I've into a bit of a wall with a client of mine. In an office of 20 people, he is the only one who experiences broken connections to his mapped network drives. I have everyone set up with about 6 mapped drives, all pointing to the same server (no DFS), and everyone else can access them lightning fast. The environment consists of a mix of Windows 7 and XP machines, all 32-bit. The server holding the data everyone is mapping to is running on Server 2008 R2, and is a domain controller. We recently swapped out their old 10/100 switch for a shiny new Dell PowerConnect gigabit switch. We have also replaced an old dying Sonicwall with a shiny new one. Everything is running on an ESX host except for the DC, where everyone is getting data from. In my client's office, we have done the following: Swapped out his computer (Win7 and XP box) Swapped out the desktop switch in his office Removed the desktop switch in his office Changed out the network cable going to the wall Ran 'net config server /autodisconnect:-1' on the server Disabled remote differential compression on his current Win7 box When we swapped out his network cable, everything seemed fine for about 4 days. Normally I would get a phone call a couple times per day letting me know that Outlook has crashed (there is a 9GB PST living on the server he is always connected to), or that his software he is running from his L drive has crashed. I almost thought I had this solved, but after we rebooted the DC the other night he all of a sudden couldn't stay connected to his mapped network drives for more than 10 minutes. When I ran 'net use' from the command prompt, it listed all the network drives where were randomly in a state of 'OK', 'Disconnected', or 'Reconnecting'. What else should I try? Maybe there is bad wiring in the wall, patch panel, or a bad port in the new switch I have in the server room?

    Read the article

  • Certificates required for WHQL-certified drivers

    - by Kasius
    The 64-bit Windows 7 image that we deploy to machines at our site does not contain all of the certificates included on a default Windows image. Automatic root certificate installation is also disabled per policy from higher in the organization. We have had a lot of trouble installing many WHQL-certified drivers from reputable companies (ex. HP, Lexmark, Dell, etc.), and I hypothesize that a required certificate is missing from one of the certificate stores on the machine. The error we typically get is: The driver cannot be installed because it is either not digitally signed or not signed in the appropriate manner. I know that it is signed. A .CAT file is included, and it has the following tree from top to bottom: Microsoft Root Authority (thumbprint a4 34 89 15 9a 52 0f 0d 93 d0 32 cc af 37 e7 fe 20 a8 b4 19) Microsoft Windows Hardware Compatibility PCA (thumbprint 93 b8 d8 82 0a 32 db 20 a5 ea b6 8d 86 ad 67 8e fa 14 ea 41) Microsoft Windows Hardware Compatibility Publisher (thumprint b0 50 45 45 42 4e be 2c 16 2f 62 5b bf 5a e6 9b 96 bf 0b 0b) What certificates are required to install WHQL-certified drivers? Is it possibly something other than certificates? Thanks! NOTE: I have posted this question on Technet as well, but honestly, I've never had a lot of luck posting questions on the Technet forums.

    Read the article

  • Best Practice - SQL 2012 & IIS in VMWare

    - by Dan Ribar
    We are pretty new to VMWare and looking for some thoughts on our environment. We have a VMWare cluster that has on one host: VM#1: MS Windows 2008 R2 Enterprise & SQL Server 2012 VM#2: MS Windows 2008 R2 Standard & IIS The IIS asp.net app talks directly to the SQL Server. We had this similar environment on physical servers a few months ago and just recently moved to the virtualized environment. Regarding the setup, we have not tweaked any of the vm resource parameters -- all is set as standard and all is working. What is observed is that the VMs seem to spool down and we get lags in response. Of course this sin't as fast as the old physical environment, but I am wondering if: *is it a good idea to run the SQL server and the IIS server on the same host? They are the only two VMs on it. The host is a new Dell R620 with 192 gb mem. does it make sense to change any CPU or memory reservations when it doesn't seem like there is any contention is there a way to keep the VMs spooled up to eliminate delays? This is a brand new squeaky clean vanilla install. What are your thoughts?

    Read the article

  • Wake-on-lan only works so many times

    - by Chance
    I have Wake-on-lan configured on my Windows XP machine so that the computer will wake up from Standby. Waking the computer from Standby via network traffic seems to work a certain number of times, say 4 or 5, then it stops working. If I restart the computer it seems to reset this behavior so that I can use WOL a few more times before it starts working. I use the command "wol" on my other, Linux machine with the appropriate IP address and MAC address of the card. I looked at the network card to see if it had different lights when WOL worked and when it didn't. When it has a solid amber light where the ethernet cable connects, WOL seems to work. When it has a flashing amber light, WOL does not. It seems that the system seems to almost "shut off" the card when it falls to sleep, but I don't know if this is a function of time or number of standby/wakeups. I have a 3Com 3c920 network card. If I look at the properties in Device Manager, I have "Allow this Device to bring the Computer out of Standby" checked. In the Advanced tab I have anything related to RWU (Remote Wake Up) enabled. I also believe I have the appropriate settings in BIOS related to Remote Wake-Up and I have tried both S1 and S3 power configurations in the BIOS. Intuitively, I would think I would uncheck "Allow the Computer to turn off this device to save power", but doing so disables the "Allow this Device to bring the Computer out of Standby" option. Does anyone know what is happening here or if there is a way to fix it? I have an integrated network card; would getting one that goes into a slot be better? I am running Windows XP on a Dell Optiplex GX240 with a 3Com 3c920 network card.

    Read the article

  • Upgrade SQLServer 2008 hardware

    - by John
    Forgive me if I'm not able to be totally clear here. It is not intentional, I'm a senior level developer in a very small company having to act like a manager at the moment. Anyway, the story is that we have 2 older dell servers with SQL Server 2008 Standard in a "cluster". I put that in quotes because I'm still not 100% clear what that means. We have 2 brand new blade servers and want to move the existing databases to the new hardware. Ok, so here is the gotcha. We need to do this with little or no down time. I'm being told that we can evict the passive node, then pull in one of the new servers. But I'm also being told that this is a dangerous step because something could go wrong that would cause the cluster to fail and then we would be left with nothing because the active server would not be able to come back up. Does anyone have any thoughts on how to handle this? I'm being told that the only way to ensure success is to have at least a day of down time where we bring up a new cluster on the new hardware and then migrate the databases 1 by 1.

    Read the article

  • Using udev to create a character device based on a driver being loaded

    - by SteveCB
    I'm in the process of setting up RAID monitoring for a number of Dell servers that use the PERC 6i integrated card. We're using Nagios at present and the check_megasasctl plugin seems to fit the bill. However, the plugin relies upon the existence of: /dev/megaraid_sas_ioctl_node This device node doesn't exist by default, you have to create it by hand using something like: mknod /dev/megaraid_sas_ioctl_node c 253 0 Now, to make the existence of this device node persistent across reboots, I thought I could write a udev rule, but as usual, I'm missing something. I thought I could create a file such as /etc/udev/rules.d/10-local/rules that contained: DRIVER=="megasas" NAME="megaraid_sas_ioctl_node" MODE="0600" But this doesn't work - no device node after a reboot. Dmesg output indicates the megasas driver is loaded and functional: megasas: 00.00.04.01-RH1 Thu July 10 09:41:51 PST 2008 megasas: 0x1000:0x0060:0x1028:0x1f0c: bus 1:slot 0:func 0 megasas: FW now in Ready state Further, I don't see any means to instruct udev on which type of device node to create: character or block. I suspect I'm failing to understand exactly how udev is meant to work. I realise I could just cheat and run MegaCLI in /etc/rc.local, redirecting output to /dev/null; it creates the megaraid_sas_ioctl_node device node as part of its execution. I just thought using udev rules would be a) cleaner and b) a useful learning exercise. Perhaps I should just dump the above mknod command in /etc/rc.local... So how do I get udev to create the /dev/megaraid_sas_ioctl_node device node based on the presence of the megasas driver? Cheers Steve

    Read the article

  • What to look for in a switch with LAN/WAN verses an iSCSI SAN?

    - by Luke
    I'm setting up a VMWare ESXi 5 environment with 3 server nodes. Dell recommended 2x Force10 S60 switches shared (iSCSI SAN, LAN/WAN). The S60 switches are extremely powerful. They have 1.25 GB of buffer cache, < 9us latency. But they are very expensive (online price ~$15k per switch, actual quote a little less). I've been told that "by the book" you should at least have 2 internal switches for SAN, and 2 switches for LAN/WAN (each with a redundant). I know some of the pros and cons of each approach. What I'm wondering is, would it be more cost effective to disjoin the SAN from LAN with less expensive switches? The answer to this question highlights what I should be looking for in a switch for the SAN. What should I be looking for in a LAN/WAN switch, in comparison to the SAN? With the above linked question for the SAN: How is buffer latency measured? When you see 36 MB of buffer cache, is that shared or per port? So 36 MB would be 768kb or 36MB per port? With 3 to 6 servers how much buffer cache do you really need? What else should I be looking at? Our application will be heavily using HTML5 websockets (high number of persistent connections). The amount of data being sent is small; Data sent between client <- server isn't broadcasted (not a chat/IM service). We will be doing some database reporting too (csv export, sums, some joins). We are a small business and on a budget. We'd probably only be able to spend no more than $20k on switches total (2 or 4).

    Read the article

  • Why can't I connect to my router's config page with Windows 7?

    - by user17940
    I've got a Belkin wireless router, and just bought a new Dell computer with Windows 7 pre-installed. I can connect to the Internet and my home network just fine, but when I try to visit my router's configuration page at http://192.168.2.1, I get a "Connection was reset" error. Nothing I do will make the router's configuration page come up in my web browser. More background information: I could always get to the router's config page from my Windows XP machine. I never had any trouble prior to getting this Windows 7 computer. I can ping 192.168.2.1 successfully from my Windows 7 computer. My PC is connected to the router by a physical CAT5 cable, not via wireless. Every device connected to my router, including the new computer, can get to the Internet with no problem. Here are some things that did not solve the problem: I tried turning off IPV6 in Windows. I tried turning off my firewall and antivirus software I tried using https instead of http I tried disabling and then enabling the network connection in Windows I tried reverting my network card driver back to an older version I have tried both Firefox and Internet Explorer web browsers. Has anyone experienced something like this before, and solved it? Thanks a lot for your help!

    Read the article

  • Two monitors with Mac Mini - one displays black despite receiving a signal

    - by alex
    My Mac Mini outputs to my two new monitors - Dell U2311Hs. The LED on the bezel displays blue when receiving a signal, or yellow otherwise. Both screens are displaying blue. It also seems my Mini can see both of them... However, one of them is black. It just displays black, but appears to be receiving a signal (when I turn the Mac off, it then displays No Signal). To make things weirder, on startup, the boot up (white with Apple logo) appears on the right monitor (the one that now displays black). Occasionally, it flickers up on the black screen for 1 second. I have tried Detect Displays. It appears to do nothing. I'm also running a dual monitor KVM. Video connections are DVI-D. How can I fix this situation? Thanks. Update This is the weirdest thing - I used the DVI-D cable that came with the KVM and it seems to have fixed it - I didn't both because it looks identical to any other DVI cable (in form an pin out). So, I will accept an answer if someone can tell me what may be the difference in these cables?

    Read the article

  • Help with Ubuntu and Windows, separate HDs

    - by LuxuryMode
    Need some major help. Running a Dell XPS/Dimension 630i. It came with "SATA 2 RAID 0 With Dual 500GB Hard Drives." I have installed a new, third non-raided drive and installed Ubuntu on it. So now I have Windows on the original hard drive and Ubuntu Linux on the new HD. When I get to the boot menu where I can select an OS, if I select windows I get an error: "No such drive, no such disk." Also, strangely in the first place, in order to even get to the bootloader menu I have had to disable ALL ports under the RAID config. Unless I do this, I will just get to a never-ending blinking cursor. I have tried every conceivable CMOS config and nothing else works. Tried setting port 3 (the new HD w/ Ubuntu) to first hard disk boot priority. Tried disabling all other ports and enabling the Ubuntu HD port and vice versa. I have some pictures of boot up: first one is strange error i get after messing with CMOS to finally get ubuntu install to work. http://imgur.com/5sqJa then boot menu: http://imgur.com/TWtLq then error: http://imgur.com/TJ1mS. Also, please note that I can actually access all files from the raided Windows drive through Ubuntu.

    Read the article

  • 100% CPU load on Ubuntu 10.04.3 LTS 64bit

    - by deadtired
    I have 2 days since I am trying to fix this issue, with no success. The server is a mysql database server. Hardware: DELL Poweredge 1950, 2x Intel Xeon Quad Core E5345 @ 2.33GHz, 16 Gb mem, 2x 146Gb SAS (software RAID1) Software: Ubuntu 10.04.3 LTS, MySQL 5.1.41 Issue: while mysql is not used and runs with no database, everything seems alright. As soon as I install a database, it has the reason to bring all 8 cores in 100% with low memory consumption. So, you can imagine the load average goes high (I saw 212 load average for the first time). The server doesn't become unresponsive, but you can see it's slow while browsing the project installed. Additional info: the database used is not more than 24MB and it was moved from a server with less resources and a lot more larger databases. So it's not the database/project. my.cnf is not a reason also, as I used both default one and the one I use on the same distribution on another server.What is interesting is that mysql doesn't close any process and runs to the limit of the max_connections. Logs are quiet. Nothing there. I switched to this Ubuntu version after I suspected some problems in the newly Ubuntu 11.10 server. This one worked alright for an hour after I made a kernel upgrade to 3.0.1 (it was using the memory also) I tested disk speed and seems alright. Some more output on the running server: dstat -cndymlp -N total -D total 3: htop command: Idea? Did anyone meet the same problem? Any fix you can think of?

    Read the article

< Previous Page | 92 93 94 95 96 97 98 99 100 101 102 103  | Next Page >