Search Results

Search found 9611 results on 385 pages for 'low power'.

Page 100/385 | < Previous Page | 96 97 98 99 100 101 102 103 104 105 106 107  | Next Page >

  • MD3200i Slow Performance and Queue Depth

    - by Caleb_S
    Read performance on our SAN is slow under certain workloads. When we compare this to some local storage, we find the local storage performing 2x as fast. The SAN performs well with a high Queue Depth, and poorly with a low queue depth. However, the local storage performs well with a low Queue Depth. I'd like to know the reason for this occurring and find out what the specific limiting factor is in this situation. MD3200i iSCSI SAN ($15,000) 6 x 600GB 15k SAS RAID5 6 x 2TB 7.2k NLS RAID5 XCOPY /j Benchmark: (Slow) 15k Array - 71MB/s (Queue Depth 1) 7.2k Array- 71MB/s (Queue Depth 1) Robycopy /MT:32 Benchmark: (Fast) 15k Array - 171MB/s (Queue Depth ~12) 7.2k Array- 128MB/s (Queue Depth ~12) , , Read Performance on a Local controller is fast under the workload the SAN is slow at. , HighPoint 2230 RAID Controller ($600) 4 x 1TB 7.2k SATA RAID5 XCOPY /j Benchmark: 7.2k Array - 145MB/s (Queue Depth 1) (appears to max out the SATA bus)

    Read the article

  • Solution for storing sata drives outside of case

    - by Jeffrey Kevin Pry
    I have a system that has 8 sata disks in a software raid 5 array using mdadm. My issue is that I want to move the drives from inside of the computer case in order to cool more efficiently. I have looked all over the web and only seem to find enclosures that hide the drives connectors behind an estata port or some other internal raid controller. Basically what I want is an enclosure or equivalent that I can run independent sata cables to and either power as well, or have it have its own power supply. I have the sata ports on the motherboard available and don't want to limit io by using one port with a multiplier or the like. One final caveat, I am a college student on a budget and don't have a fortune to spend on such an enclosure. Thanks in advance for your help and advice.

    Read the article

  • Windows Home Server Passwords Do Not Match

    - by Ben Fulton
    I have a Windows Home Server that chunks along just fine most of the time. I've never bothered to put it on a UPS and so it's vulnerable to power outages that happen a few times a year. This most recent time, it came back and seemed to be fine, but whenever I try to access a shared folder I get "Passwords do not match". They matched before the power went out, and I couldn't update the WHS password since I apparently didn't know the old one. How do I fix this? (I asked this on ServerFault and they recommended it be asked here instead)

    Read the article

  • Should server spare parts be stored in climate controlled storage?

    - by Shane Wealti
    What is a best practice for storing server spares (hard drives, RAM, power supplies, etc) with respect to how/where they are stored? Some options are storing them in climate controlled storage or just a standard warehouse-type stockroom? My understanding is that all other things being equal climate-controlled storage is preferred. What are the risks of storing that type of thing in a non-climate-controlled, somewhat dusty shelving area? Conversely are there risks to storing spares in a climate controlled area? If there are space limitations in climate controlled storage are there some parts, such as hard drives, which should be in climate controlled, while other parts such as power supplies will probably be ok in non climate controlled storage?

    Read the article

  • High fan speed after return from suspend (on Ubuntu)

    - by Bolo
    Hi, I've got a HP ProBook 5310m laptop with Ubuntu 10.04 (32 bit). When I return from suspend, the fan speed is usually very high: FDTZ sensor reports "90 °C". Yes, the units are wrong, since FDTZ does not report temperature, but fan speed – that's probably just a small bug in reporting. Interestingly, when I plug or unplug the power cable for a moment, the fan speed returns back to normal. My questions: Where can I report this problem? Is it about ACPI support in the kernel? What is the address of the relevant bug tracker? As a workaround for now, how can I programmatically trigger a behavior equivalent to (un)plugging the power cable. More generally, how can I force ACPI to recalculate fan speed? Ideally, I'm looking for something like echo foo > /proc/bar. Thanks in advance!

    Read the article

  • Computer not working, motherboard is suspect

    - by Arlen Beiler
    I have a problem with my computer. I have a GeForce 6100 M9 Motherboard, which I suspect is broke. The capacitors beside the CPU are corroded and the computer doesn't do anything except start the fans when I push the power button. The problem is that I can't find another motherboard as they apparently don't sell this model anymore. I have tested the Power Supply and it appears to be working. Any advice would be appreciated. Different forums have mentioned that you can replace the capacitors. Any help on this would be appreciated.

    Read the article

  • PC boots on then off & 30 sec. later on again, it wiil shut off on itself mostly in idle or just unexpecticly

    - by Jody
    This problem started w/ my sons desktop, it would just shut off after a bit of work or stay on for a long time & to get it to unfreeze is to cold boot it, i put a new HDD in & I still have the same issue, RAM is good power supply fan is moving quite as well as all the rest of the fans it has stayed fairly dust free, i'm at a loss ,I have defaulted all the factory settings changed battery & ungraded to a new OS. I still have the same problem. the power light stays on after it has shut down & when upon starting it goes straight to safe mode option page, I start in last good config. reboots again takes 30 sec. to boot & will work again for a while, the only other thing I haven't tried was a graphic card replace, i'm onboard video now & have been.

    Read the article

  • Very High Network out in ec2 instance

    - by Jatin
    I launched an ubuntu-14.04-64bit instance in Amazon EC2 two days back. And I started Tomcat 7.0.54 in that instance and deployed my application war files. It has no other software installed other than tomcat and the default ones. In the past 2 days, its shows 858 GB of Data Transfer(Network Out) from that instance. I have attached a graph of Amazon CloudWatch Metric "Network Out" My application does not do any data download/upload. Its a Java Spring application and the front end is in HTML&Javascript. My application traffic was very low (less than 20 hits) in those 2 days. Is there a way to find out why these data transfers happened and also to find what data has been transferred. If you can see in graph, network out was 20gb per minute. Some more info: Network in was negligible CPU Utilization was very high Everything else was low

    Read the article

  • Prevent Windows 7 from unpluging External HDD

    - by marverix
    I have installed Windows 7 as my media server. I pluged in 500GB external HDD via USB. I have changed power plan to Best Performance and changed advenced power settings to never turn off HDD etc. I even yesterday wrote powershell script (create and delete folder on this disk) and I have added it to harmonogram to run every 5 minutes starting from system boot. And nothing! Disk after some time (I realy can't say when) is turning off and Windows show "Unknown Device" in Device Manager. Then only system reboot or disk reboot helps. Any ideas how to prevent Windows 7 from stopping my external HDD? Cheers!

    Read the article

  • Random Computer Crashes

    - by Josh W.
    Ok, here's a wierd one for you all. Occasionally my PC here at work will crash in a very peculiar way. My dual monitors will suddenly go blank as if there is no longer a video signal, the USB mouse light will go dark and mouse stays unresponsive, the keyboard lights will not change status when the appropriate keys are pressed (Num/Caps/Scoll Lock). The CD Tray WILL open and close. But the computer will not respond to a ping request. For all intents & purposes it's as if the computer is off, except it wasn't intentional by me. The power light and internal fans are still on and I've now lost any unsaved work. Now here's where it gets wierd. This PC is part of a batch of PC's we got from a local vendor who does our initial system builds. Mine, and 6 other co-workers PCs all have the same issue. Originally we thought it was a bad combination of hardware, but through trial and error the only thing we haven't eliminated are the OS, Mobo & CPU. The problem was so bad for some of them that they ended up going back to their 5 year old dinosaurs in order to get some work done, for me the problem isn't as bad, maybe once every other day or so, but still enough to bite me in the ass if I've forgotten my ritualistic pressing of CTRL-S every 1-5 minutes. In this case we've tried two different video cards, two different power supplies, two different memory configurations, running on a UPS/not on UPS, updating/rolling back video drivers, three different bios revisions. The only things we haven't swapped are the mobo & cpu, mainly because a new mobo means a new Hardware Abstraction Layer, ie re-install of windows and there's alot of other software on this PC that takes forever to reload by hand. There was a base image that our systems team created with all the drivers installed and the basic setup of software our company uses, but they then must customize the setup for us programmers so it takes a while to get a new configuration up and going. I'm a programmer by day and am usually pretty good at diagnosing computer problems whether through trial and error or not. We've pretty much exhausted all the ideas we can think of here, short of a new mobo/cpu. Was hoping someone out there might have anything else we can try.. Relevant Parts: OS: XP Pro 32-bit Motherboard: Intel DG41RQ CPU: Intel Core-2 Quad Q9400 @ 2.66GHz Current BIOS Version/Date Intel Corp. RQG4110H.86A.0014.2010.0306.1151, 3/6/2010 Dual LCD's, Viewsonic VG930m & Samsung SyncMaster 910v (other people have different models, but listed in case there's some very wierd problem with the signals being sent/received) PS/2 Keyboard USB Microsoft Intellimouse BIOS Versions Tried: R 0013 12/23/2009 R 0014 3/6/2010 Video cards Tried GeForce 8400 GS Radeon HD 4350 - ASUS EAH4350 Two Different Power Supplies a 380W & 550W Ram Configurations 2GB - 1 x 2GB 4GB - 2 x 2GB

    Read the article

  • SEAGATE Barracuda 7200.11 HDD not running

    - by Dane411
    After a huge research, I'm stuck at the beggining of getting my HDD data back. Whats happening to me is that in the moment when I plug the power wire to my external 1TB SEAGATE Barracuda 7200.11 ST31000333AS HDD Fw LC15, it makes the sound like it's spinning to almost full speed and then shuts down and spins up again, and so on. It's well known that those HDDs have a bad firmware that someday randomly fails. There are like 2 main problems identified, BSY (busy) state, and LBA0 error. Last time I connected it to power nothing happened, it didnt try to start at all, is it that so called bricked state? I guess my HDDs error is the first one, but I dont really know if what I described is that BSY state or not, neither I know how to check it. How could I know it? Thank you so much!

    Read the article

  • What is the command to use to put your computer to sleep (not hibernate)?

    - by airrick
    I want to put my windows pc (win7) into a sleep state via command line (so i can bind to macro button on keyboard). The power button on the PC is setup to but the computer to sleep (but it's down on the floor and I'm too lazy to reach down) it exactly how I want it (sleeps using hybrid mode in case I loose power) The sleep command on the shutdown menu also works. most info I found says to use; %windir%\system32\rundll32.exe PowrProf.dll, SetSuspendState 0,1,0 But this puts the computer in hibernate mode. I do have hibernate disabled but using hybrid sleep. So, What is the command to use to put your computer to sleep (not hibernate)?

    Read the article

  • Excel - add target line to stacked bar chart

    - by Chris W
    I've got a stacked bar chart. I'm displaying a set of floating bars to represent hi/low ranges for some metrics, by using a transparent fill on the bottom section of the bar I achieve the desired look. What I now need to do is add a horizontal line across the chart to indicate how a particular users score relates to all of these hi/low ranges therefore the placement of this line needs to be dynamic based on a value in a cell. Is there anyway to do this as I can't find an easy option. If this was a simple bar chart I could add the target scores as new series and use the line chart type but I don't seem able to overlay a second series on the stacked bar chart. I'm using 2003 at the moment but run this in 2007 if that helps.

    Read the article

  • CPU fan turns on and off repeatedly without booting

    - by rnso
    My PC has suddenly stopped starting up. On checking with case open, the CPU fan starts running when the power is turned on, but it stops after about 2-3 seconds, restarts again after about 2-3 seconds and the loop is repeated. There is no beep and nothing appears on the screen. On searching the internet, I found there could be several reasons for this. I tried removing hard-disk, CD drive, tightening connections etc but of no avial. I also tried using a new power supply but the response is the same. Where could be the problem and how can it be solved? Thanks in advance.

    Read the article

  • new pc..noisy fan

    - by BRQ
    It's a new build, but it's always had noisy fans. From start to end, they will not stop running. The case is a cooler master which I believe comes with a fan that is not controlled by BIOS (according to technician), so that may be the source of the problem..but my lack of knowledge on the matter prevents me from making a reasonable assessment. Here are readings from CoreTemp: Model: Intel Core i7 870 (Lynnfield) Platform: LAG 1156 (Socket H) Frequency: 1658.23MHz (132.66 x 12.5) Tj. Max: 99 C Core #0: low= 34 C; high= 42 C; Load= 0% Core #1: low 31 C; high 42 C; load= 0% Core #3: 35 C; 42 C; 0% Any input will be appreciated.

    Read the article

  • Thinkpad speaker turns mute - Linux Codec issue?

    - by Curlew
    At some point a few days ago the speakers on my Lenovo Thinkpad T410 (Model number: 2537A11) suddenly stopped working randomly. This error happens every time I watch a video or listen to a music file. The sound just abruptly stops. At the moment, I can't produce a single sound no matter what I do. I am using Debian GNU/Linux on this laptop and there doesn't appear to be anything else wrong (the fan is working, no abnormal heat (staying around ~40°C), no other obvious errors or problems). Here is the output of a nice program someone pointed me to: martin@martin:~/Downloads$ sudo python run.py --monitor Using temporary directory: /dev/shm/hda-analyzer You may remove this directory when finished or if you like to download the most recent copy of hda-analyzer tool. Downloading file hda_analyzer.py Downloading file hda_guilib.py Downloading file hda_codec.py Downloading file hda_proc.py Downloading file hda_graph.py Downloading file hda_mixer.py Downloaded all files, executing hda_analyzer.py Watching 1 cards ====================================== Sound is working normally and then it stops and the following lines appear: Diff for codec 0/0 (0x14f15069): --- +++ @@ -164,17 +164,17 @@ Power: setting=D0, actual=D0 Node 0x1f [Pin Complex] wcaps 0x400501: Stereo Pincap 0x00000010: OUT Pin Default 0x901701f0: [Fixed] Speaker at Int N/A Conn = Analog, Color = Unknown DefAssociation = 0xf, Sequence = 0x0 Misc = NO_PRESENCE Pin-ctls: 0x40: OUT - Power: setting=D0, actual=D0 + Power: setting=D3, actual=D3 Connection: 2 0x10* 0x11 Node 0x20 [Pin Complex] wcaps 0x400781: Stereo Digital Pincap 0x00000010: OUT Pin Default 0x40f001f0: [N/A] Other at Ext N/A Conn = Unknown, Color = Unknown DefAssociation = 0xf, Sequence = 0x0 Misc = NO_PRESENCE And now there is also an error in the dmesg output hda-intel: IRQ timing workaround is activated for card #0. Suggest a bigger bdl_pos_adj. I changed the bdl_pos_adj to various numbers (-1, 0, 64, 1024) and either there is no change at all or dmesg reports that the adjustment is too big. I wonder if this bdl_pos_adj is the real reason for the error. Here is my hardware information provided by alsa-info.sh website. Okay, i did some serious testing and even installed Windows and now i officially conclude that this is a hard-ware related issue with my Laptop speakers. Reason: The error occurs in my installed Debian Linux, an Ubuntu Live distribution and Windows XP No error-message appears in all of the OS. The sound just keeps running and i can't hear a thing. I tested different setups, including OSS, ALSA and the pulseaudio server on top If i use my new usb-headphones i can hear sound all the time without any sudden silences. So obviously, although hard to believe, my laptop speakers are not okay (never heard of similar cases). I'll award the bounty to anyone who can point me to good tutorials or the procedure how to exchange my T410 speakers (i still have warranty. The laptop was bought in Germany, but now i am in Denmark). Or to someone who can explain me the output from hda-analyzer (big log above).

    Read the article

  • Linux QoS: bulk data transmission during idle times

    - by syneticon-dj
    How would I do a QoS setup where a certain low-priority data stream would get up to X Mbps of bandwidth, but only if the current total bandwidth (of all streams/classes) on this interface does not exceed X? At the same time, other data streams / classes must not be limited to X. The use case is an ISP billing the traffic by calculating the bandwidth average over 5 minute intervals and billing the maximum. I would like to keep the maximum usage to a minimum (i.e. quench the bulk transfer during interface busy times) but get the data through during idle/low traffic times. Looking at the frequently used classful schedulers CBQ, HTB and HSFC I cannot see a straightforward way to accomplish this.

    Read the article

  • Radiation from a UPS

    - by Erel Segal
    In our office, there are frequent eletric shortages that harm my desktop computer, so I wanted to install a UPS. However, my office-mates pointed me to papers talking about hazardous radiation from the UPS. The UPS manufacturers themselves recommend to put the UPS several meters away from humans, which is not possible because our office is small (the power is about 0.5 meters from us). As an alternative to UPS, my office-mates recommended that I switch to a laptop, which has a battery so it's immune to shortages. I have several questions: Is it true that the radiation from a laptop battery is lower than the radiation from a UPS? They do just the same thing - supply power using a battery! If the answer to 1 is yes - is there an alternative way to attach a battery, similar to a laptop battery, to a desktop computer? If the answer to 1 is no - how can I prove this to my office-mates, so that they let me use UPS?

    Read the article

  • How do I negotiate for colo space?

    - by randy melder
    I guess this isn't a technical question, but it definitely is something IT teams deal with, so here goes: I'm looking at getting a rack at a local colocation facility. I'm weighing the options versus building out in a cloud platform. We are REALLY low bandwidth and power. There's a total of six hosts for the total operation. You can assume we use <= 10 amps of power and <= 2Mbps 95th percentile. Do you have any advice for getting the best deal?

    Read the article

  • Laptop goes black after a minute or so

    - by ZEDA-NL
    I have a laptop that is behaving strangely. When I turn it on, it does everything what it is supposed to do, but after a minute or so I hear a Click and all goes black. It's like it turns off the power. It doesn't matter what the laptop is doing. It also happens when it's just waiting in the Bios setup menu. Has someone experienced this before? Can it be the power supply? Can it be a cooling problem? Any ideas? By the way, it's a Compaq Presario Laptop, maybe 3 years old already.

    Read the article

  • Why does the CPU usage reach 100% when laptop is plugged in?

    - by Mayank
    I have an HP Elitebook 8440p with Windows 7 Ultimate, i7 Processor and 8 GB RAM. For the last couple of days, when I plug-in my laptop for charging, the CPU usage shoots up to 100% and remains there for around 15 minutes. No offending process shows up in Task Manager/Process Explorer but the laptop is practically unusable for that time. The CPU usage becomes normal when I remove the power cord but shoots up again when plugged back. This is happening with different power adapters/wall sockets so it might not be a faulty adapter issue. Why is this happening and any pointer to resolve this issue?

    Read the article

  • Running out of LowMem with Ubuntu PAE Kernel and 32GB of RAM

    - by magneticMonster
    I'm running a Java data import process on a 32-bit Ubuntu 10 PAE kernel machine. After running the process for a while, the oom-killer zaps my Java process. After some Googling and digging through docs, it looks like the system is running out of LowMem. I started the process for the third time and am watching free -lm show me Low: 464 386 77 with the free value (77MB) slowly decreasing. Why am I running out of lowmem and how do I increase it? Some details: $ cat /proc/sys/vm/lowmem_reserve_ratio 256 256 32 $ free -lm total used free shared buffers cached Mem: 32086 24611 7475 0 0 24012 Low: 464 407 57 High: 31621 24204 7417 -/+ buffers/cache: 598 31487 Swap: 2047 0 2047

    Read the article

  • Hibernate speed, and hard drive temperature

    - by cometbill
    My computer is taking in the region of 4 minutes or so, to hibernate 4GB of RAM. Also, resting my hand on the top of it is rather hot to the touch, so I ran CrystalDisk Info and that is reporting a temperature of 49 degrees C. I It's a Western Digital 5400 rpm drive, I've had it in the laptop since I bought it for most of the 2.75 years I've had it. Power on Count is 1219 Power on Hours is 3940 hours Boot up time is quicker than resuming from hibernate, too. Is there anything I can / should check ? Advice is greatly appreciated.

    Read the article

  • X200 Tablet notebook won't start after BIOS Update

    - by THEn
    I have LENOVO X200 Tablet and I ran the BIOS Update and the computer won't start after the BIOS update. When I ran the BIOS update utility it ran everything fine and asked to restart the computer but it wont start screen is blank. I unplugged the power and took of the battery and put them back and still not starting. Now it has [Power On] indicator light on and screen is not starting. I tried pressing F1 button while trying to start the computer but it doesn't do react to anything. Please help how I can start my Tablet. The update utility is http://support.lenovo.com/en_US/downloads/detail.page?LegacyDocID=MIGR-70651 Does any body know if X200 have any kind of hardware switch to reset the BIOS or any thing? What would be the best way to fix my BIOS? Thank you.

    Read the article

< Previous Page | 96 97 98 99 100 101 102 103 104 105 106 107  | Next Page >