  • Mounting fuse sshfs fails when invoked by Cron on FreeBSD 9.0

    - by Tal
    I have a remote server filesystem that I'm attempting to mount locally on a FreeBSD 9 machine via FUSE sshfs, and Cron for a backup routine. I have ssh keys between the boxes setup to allow for passwordless login as the root user on the local machine. Cron is set to run the following script (in Root's crontab): #!/bin/sh echo "Mounting Share" /usr/local/bin/sshfs -C -o reconnect -o idmap=user -o workaround=all <remote user>@<remote domain>.com: /mnt/remote_server As root, I can run this script on the command line without issue, and without being asked for a password the share mounts successfully. Yet, when run by Cron the script fails. The path to sshfs is identical to the value of which sshfs Here is the email root receives from the Cron Daemon: X-Cron-Env: <SHELL=/bin/sh> X-Cron-Env: <HOME=/root> X-Cron-Env: <PATH=/usr/bin:/bin> X-Cron-Env: <LOGNAME=root> X-Cron-Env: <USER=root> Mounting Share fuse: failed to exec mount program: No such file or directory fuse: failed to mount file system: No such file or directory I'm stumped as to why I'm receiving No such file or directory in this instance. It further seems odd given that the paths appear to be correct. I've also attempted to compare the output of env on the shell with env inserted into the script. I don't see any environment variables that should cause this trouble. At bootup, FUSE reports its version as: fuse4bsd: version 0.3.9-pre1, FUSE ABI 7.8 Help me ServerFault wizards, you're my only hope!

    Read the article

  • Periodic internet connection drops

    - by user9647
    My setup is a dsl modem, and a dlink di 524M router. I'm also using a Witopia VPN which runs through OpenVPN. I've been having trouble with the internet connection dropping very frequently. It comes back shortly, without even a router/modem/computer restart. This happens as frequently as every ten minutes. Occasionally (not often) it will last as long as an hour or two without dropping. When it drops, I can get it back almost immediately by clicking Reconnect in the OpenVPN GUI and letting that do it's thing. It's worth noting that I'm in China. Calling support is a bit difficult because of that. Also I don't really understand all of the router's software, although I've got it generally figured out. I've tried a bunch of stuff, attempts to diagnose and/or fix the problem. No success with any of the following: I've power cycled both the modem and the router. I've tried an ethernet connection to the router. I've connected without the VPN. I've disabled IEEE authentication on all connections. I've checked for viruses. I've tried lifting it off the ground so as to prevent overheating.

    Read the article

  • windows 7 clock jumps back about every hour + internet disconnects

    - by IlyaD
    I have the weirdest problem, for the last few days every hour or so (not exact) the clock jumps about back in jumps of 15 to 60 minutes and after some time the internet disconnects. i can reconnect the internet by unplugging and plugging back the network cable. This is the second time this problem happens to me, the first time was when I installed VirtualBox. whaen I removed it the problem was gone. This time I have no idea what triggered it, the only thing I installed about the time the problem started was iTunes update (10.5.1) I tried removing it but the problem remained. (also tried to remove other programs i installed day or 2 before and it also didn't help) also, this is not a VM and currently I don't have any VM software. any ideas..? UPDATE since the solution is in the comments i'll write it here - apparently the windows time service got broken, this is the fix: http://technet.microsoft.com/en-us/library/cc738995(WS.10).aspx (run "fix it" from IE browser only) UPDATE 2 The fix didn't work, about 2 hours passed and first the internet disconnected and then the clock jumped back... This probably means that the problem is not only in the clock

    Read the article

  • How to resolve 'No internet connectivity issues' with a Virtualised 2008 R2 Server using Forefront UAG

    - by user684589
    I have spent some considerable time reading up on as many possible blogs and articles as I can to help me solve why my VM (Running on Hyper-V) for DirectAccess has suddenly stopped being able to access the internet. The VM setup shares the same internet connection on which I have written and submitted this question so I know that the actual underlying internet connection is fully functional. Previous to last week the DirectAccess was fully functional and had no issues. This is a recent problem which was led up to by a number of consistent crashes on the DA machine when access was attempted. Upon reboot all seemed well until recently. I am not certain whether it is relevant, but previously to this I had a number of power issues where the entire VM host shutdown unexpectedly leaving around 8 VM's in a bad way. Upon restart, the UAG DirectAccess machine was unable to access its configuration service (although the service was started) but this seemed to relate to the Light-Weight Active Directory Service AD LDS which had a corrupted database. Having repaired this database, I restarted the service and could subsequently reconnect to the configuration service again. For good measure I re-bound the network adapters (virtualised through Hyper-V) and DirectAccess claimed to be all happy again. However as it stands my machine is still unable to access the internet showing the "No internet connectivity" exclamation mark for the external facing NIC. I have also tried removing the adapters, disabling, re-enabling and the problem persists. The intranet part of the VM CorpNet seems to be fully functional as before and I'm running out of ideas. Any input would be greatly appreciated. I am not an advanced Domain Administrator so please be gentle.

    Read the article

  • Wi-Fi won't automatically connect (box in Windows configuration gets unchecked)

    - by greg88
    The checkbox that says "Use windows to configure my wireless network settings" keeps getting unchecked (Wirless Network Connection - Change advanced settings - Wireless networks tab.) How do I stop that from happening? (So the wi-fi will reconnect.) When I manually re-check the box, it automatically connects.) I have a D-Link AirPremier DWL-G550 PCI adapter. I installed the newest driver, 5.3.0.46, and that didn't solve the problem. I took the "Atheros Client Utility" (the program window says "D-Link AirPremier Client Utility" when you run it) out of the start menu, rebooted, and that didn't solve the problem. (That utility puts a signal bar similiar to the one MS Windows puts there, and it's gone now.) The D-Link client utility has an option to automatically connect to preferred networks, but it is greyed out. It is also greyed out if I install the driver and utility right off the D-Link installation CD, so the problem isn't that the utility and driver are incompatible versions. I want to use Windows to handle the connection anyway, as the D-Link utility is garbage. Windows XP SP3 w/all current updates.

    Read the article

  • Using GPO to collect data about VMware view activity

    - by MoSiAc
    Our security group wants us to begin logging data for external access to our view enviroment. At first we thought that view security would be logging all source ip's that are external in nature so if for some reason there is an intrusion we would have record of it there. Of course our firewall logs all that information but correlating it to view is sketchy at best with our current implementation. We know on viewdesktops there is a set of keys in VolitateEnviroment that contains stuff such as source ip and username, etc. We have a script in place that, when run as a logon script attached to a user account in AD collects the information as we need it. If we have a GPO run the same script the information does not get collected. We feel like there is a piece of the puzzle we're missing but we don't know what. If anyone knows what we're forgetting or misconfiguring that would be great, or if you have a better way of us collecting external source ip's for view specifically we'd be interested in that as well. Thanks, EDIT CODE Batch script to dump to text file @echo off timeout 20 echo %computername%/%username% %time% %date% c:\vdi\vmware.txt echo ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~c:\vdi\vmware.txt reg query "HKEY_CURRENT_USER\Volatile Environment" /v "ViewClient_LoggedOn_Username"c:\vdi\vmware.txt reg query "HKEY_CURRENT_USER\Volatile Environment" /v "ViewClient_IP_Address"c:\vdi\vmware.txt echo.c:\vdi\vmware.txt VB Script to display values Const HKEY_CURRENT_USER = &H80000001 Set wmiLocator=CreateObject("WbemScripting.SWbemLocator") Set wmiNameSpace = wmiLocator.ConnectServer(".", "root\default") Set objRegistry = wmiNameSpace.Get("StdRegProv") sPath = "Volatile Environment" lRC = objRegistry.GetStringValue(HKEY_CURRENT_USER, sPath, "ViewClien_Machine_Name", vMachine) lRC = objRegistry.GetStringValue(HKEY_CURRENT_USER, sPath, "ViewClien_IP_Address", vIP) lRC = objRegistry.GetStringValue(HKEY_CURRENT_USER, sPath, "ViewClien_MAC_Address", vMAC) msgbox "The Remote Device Name is " & vMachine & " @ " & vIP & " (" & vMAC & ") " he wanted me to mention that the batch file actually runs and I can see it counting down when I reconnect but it does not grab the registry values.

    Read the article

  • I have to manually change the DNS suffix order every time I connect to VPN. Can I change this permanently or fix the problem somehow?

    - by CarlB
    Sorry in advance but I'm a programmer, not a network engineer, so I'm a noob at this stuff. Anyway, when I am not connected to VPN from my work PC at home, I have the following DNS suffixes listed (real domain names substituted): enterprise.org network.org company.com us.enterprise.org After connecting to VPN, one more DNS suffix is added to the very top of the list: problem-domain.com At this point, most network functions that I can normally perform when actually connected to the LAN in the office are unusable. I get error messages about the network paths not being found and what-not. Anyway, I played around with the suffixes and realized that if I just moved problem-domain.com down one spot to the second in the list, all the problems went away. Unfortunately, it returns to the top spot every time I reconnect, and I tend to get disconnected frequently. Is there something else I can do about this or should I just contact the IT department? I've had this problem before and they weren't able to resolve it but I suppose it would be worth trying again if I could get a different person on the job. What I don't understand is that I thought it didn't matter what order the suffixes were in? Isn't Windows supposed to go through each suffix until it finds a match (or has gone through all the suffixes)? Why is it quitting after the first one? Thanks in advance.

    Read the article

  • Moving an external hard drive while running

    - by user1108939
    I mean physically moving the drive around. I've never dealt with external hard drives before. Just plugged this wd mypassport to test the transfer rate. At one point I 'safely ejected' the drive. A minute later I decide to check the underside of the drive, not realizing the disk is still spinning. I lift the drive, rotating my writs about 70 degrees to the left... I hear a sequence of three high pitched sounds. I couldn't determine whether that was an indication beep by an internal security feature or the head scratching the plate (oh god...). Drive stops and usb power is disconnected. I reconnect it - it shows up fine - reads/writes. The drive was not reading/writing when i moved it. Did I damage my drive? Are these things that fragile? I thought them to be at least as durable as a standard 2.5" internal drive. Am I mistaken?

    Read the article

  • computer randomly restarting. both in game and out of game

    - by eric
    first my specs are. AMD Phenom II x4 955 processor 3.2ghz 20gb ddr3 ram 4Gb Nvidia Geforce GTX 770 850w Corsair tx850w psu Gigabyte ud3 mobo Windows 7 professional I recently uprgraded my vid card to gtx770 and upgraded my psu to the 850w thats in it now. i did a reformat with the installation of the new gpu and psu and started fresh and only have a couple programs installed (diablo3, nvidia control panel, wow, and steam). all drivers are up to date and everything is hooked up correctly. the problem is it will randomly shut down. no blue screen. just turns itself straight off and reboots after a couple seconds. occasionally i will have to unplug the power cable from the psu for a few minutes then reconnect and it will start up. it seems pretty random. sometimes it does it when my pc is just sitting there on the home screen. and sometimes it does it during games. and sometimes it doesnt do it for days at a time. i noticed the psu felt hot so i put an extra fan blowing straight onto both the psu and gpu and neither feel overly hot after it shuts down now. could it just be that it is a psu problem. the psu was taken from another machine but wasnt having this problem in that machine. i have seen a few articles online about gtx770 doing the same thing. but i havent found any answers or solutions. any help will be appreciated. im sure the 850w is enough to power my machine, im just stumped and ran out of ideas to fix it. i have even returned the video card for another thinking it might have been an issue with that particular card, but still gettin the same problem.

    Read the article

  • Using RabbitMQ (Java client), is there a way to determine if network connection is closed during con

    - by MItch Branting
    I'm using RabbitMQ on RHEL 5.3 using the Java client. I have 2 nodes (machines). Node1 is consuming messages from a queue on Node2 using the Java helper class QueueingConsumer. QueueingConsumer consumer = new QueueingConsumer(channel); channel.basicConsume("MyQueueOnNode2", noAck, consumer); while (true) { QueueingConsumer.Delivery delivery = consumer.nextDelivery(); ... Process message - delivery.getBody() } If the interface is brought down on Node1 or Node2 (e.g. ifconfig eth1 down), the client (above) never knows the network isn't there anymore. Does RabbitMQ provide some type of configuration on the Java client that can be used to determine if the connection has gone away. Shutting down the RabbitMQ server on Node2 will trigger a ShutdownSignalException, which can be caught and the app can go into a reconnect loop. But bringing down the interface doesn't cause any type of exception to happen, so the code will be waiting forever on consumer.nextDelivery(). I've also tried using the timeout version of this call. e.g. QueueingConsumer consumer = new QueueingConsumer(channel); channel.basicConsume("MyQueueOnNode2", noAck, consumer); int timeout_ms = 30000; while (true) { QueueingConsumer.Delivery delivery = consumer.nextDelivery(timeout_ms); if (delivery == null) { if (channel.isOpen() == false) // Seems to always return true { throw new ShutdownSignalException(); } } else { ... Process message - delivery.getBody() } } but appears that this always returns true (even though the interface is down). I assume registering for the ShutdownListener on the connection will yield the same results, but haven't tried that yet. Is there a way to configure some sort of heartbeat, or do you just have to write custom lease logic (e.g. "I'm here now") in order to get this to work?

    Read the article

  • NHibernate, Databinding to DataGridView, Lazy Loading, and Session managment - need advice

    - by Tom Bushell
    My main application form (WinForms) has a DataGridView, that uses DataBinding and Fluent NHibernate to display data from a SQLite database. This form is open for the entire time the application is running. For performance reasons, I set the convention DefaultLazy.Always() for all DB access. So far, the only way I've found to make this work is to keep a Session (let's call it MainSession) open all the time for the main form, so NHibernate can lazy load new data as the user navigates with the grid. Another part of the application can run in the background, and Save to the DB. Currently, (after considerable struggle), my approach is to call MainSession.Disconnect(), create a disposable Session for each Save, and MainSession.Reconnect() after finishing the Save. Otherwise SQLite will throw "The database file is locked" exceptions. This seems to be working well so far, but past experience has made me nervous about keeping a session open for a long time (I ran into performance problems when I tried to use a single session for both Saves and Loads - the cache filled up, and bogged down everything - see http://stackoverflow.com/questions/2526675/commit-is-very-slow-in-my-nhibernate-sqlite-project). So, my question - is this a good approach, or am I looking at problems down the road? If it's a bad approach, what are the alternatives? I've considered opening and closing my main session whenever the user navigates with the grid, but it's not obvious to me how I would do that - hook every event from the grid that could possibly cause a lazy load? I have the nagging feeling that trying to manage my own sessions this way is fundamentally the wrong approach, but it's not obvious what the right one is.

    Read the article

  • Error creating Rails DB using rake db:create

    - by Simon
    Hi- I'm attempting to get my first "hello world" rails example going using the rails' getting started guide on my OSX 10.6.3 box. When I go to execute the first rake db:create command (I'm using mysql) I get: simon@/Users/simon/source/rails/blog/config: rake db:create (in /Users/simon/source/rails/blog) Couldn't create database for {"reconnect"=>false, "encoding"=>"utf8", "username"=>"root", "adapter"=>"mysql", "database"=>"blog_development", "pool"=>5, "password"=>nil, "socket"=>"/opt/local/var/run/mysql5/mysqld.sock"}, charset: utf8, collation: utf8_unicode_ci (if you set the charset manually, make sure you have a matching collation) I found plenty of stackoverflow questions addressing this problem with the following advice: Verify that user and password are correct (I'm running w/ no password for root on my dev box) Verify that the socket is correct - I can cat the socket, so I assume it's correct Verify that the user can create a DB (As you can see root can connect and create a this DB no problem) simon@/Users/simon/source/rails/blog/config: mysql -uroot -hlocalhost Welcome to the MySQL monitor. Commands end with ; or \g. Your MySQL connection id is 16 Server version: 5.1.45 Source distribution Type 'help;' or '\h' for help. Type '\c' to clear the current input statement. mysql create database blog_development; Query OK, 1 row affected (0.00 sec) Any idea on what might be going on here?

    Read the article

  • C# Windows Mobile 6.5 and TCP connections

    - by Phillip
    Hello, I am developing an application which makes a TCP connection out to our company server to pull down data and provide real-time data updates when the information changes. I am using the .NET Compact Framework for the development and the .NET Framework 3.5 (soon to update to 4.0) for the server-side TCP connection. I want to leave the connection open after the initial data is sent to the device from the server in order to keep the server in contact with the device should data updates need to be sent to the device. We already considered doing a WCF or connect/disconnect type of connection but we believe the overhead on the server for creating the session, transmitting and session cleanup would be unacceptable. (each device would be connecting every 60-90 seconds.) So, leaving the connection open is the best option. What I need to know is, when I leave the TCP connection open, do I need to manually transmit a heartbeat (and if so how do I do that with the .NET Compact Framework) or will the framework/stack do that for me? We have code that allows up to reconnect if the device gets disconnected (from network switching or a voice call) so that is handled. Thanks,

    Read the article

  • Lost connection to MySQL server during query

    - by Otavio
    I have a huge table and I need to process all rows in it. I'm always getting this Lost connection message and I'm not able to reconnect and restore the cursor to the last position it was. This is basically the code I have here: # import MySQLdb class DB: conn = None def connect(self): self.conn = MySQLdb.connect('hostname', 'user', '*****', 'some_table', cursorclass=MySQLdb.cursors.SSCursor) def query(self, sql): try: cursor = self.conn.cursor() cursor.execute(sql) except (AttributeError, MySQLdb.OperationalError): self.connect() cursor = self.conn.cursor() cursor.execute(sql) return cursor # # db = DB() sql = "SELECT bla FROM foo" data = db.query(sql) for row in data: do_something(row) # But I'm always getting this: # Traceback (most recent call last): File "teste.py", line 124, in <module> run() File "teste.py", line 109, in run for row in data: File "/usr/lib64/python2.5/site-packages/MySQLdb/cursors.py", line 417, in next row = self.fetchone() File "/usr/lib64/python2.5/site-packages/MySQLdb/cursors.py", line 388, in fetchone r = self._fetch_row(1) File "/usr/lib64/python2.5/site-packages/MySQLdb/cursors.py", line 285, in _fetch_row return self._result.fetch_row(size, self._fetch_type) _mysql_exceptions.OperationalError: (2013, 'Lost connection to MySQL server during query') Exception _mysql_exceptions.OperationalError: (2013, 'Lost connection to MySQL server during query') in <bound method SSCursor.__del__ of <MySQLdb.cursors.SSCursor object at 0x7f7e3c8da410>> ignored # Do you have any idea?

    Read the article

  • C# Communication between threads.

    - by GT
    Hi, I am using .NET 3.5 and am trying to wrap my head around a problem (not being a supreme threading expert bear with me). I have a windows service which has a very intensive process that is always running, I have put this process onto a separate thread so that the main thread of my service can handle operational tasks - i.e., service audit cycles, handling configuration changes, etc, etc. I'm starting the thread via the typical ThreadStart to a method which kicks the process off - call it workerthread. On this workerthread I am sending data to another server, as is expected the server reboots every now and again and connection is lost and I need to re-establish the connection (I am notified by the lost of connection via an event). From here I do my reconnect logic and I am back in and running, however what I easily started to notice to happen was that I was creating this worker thread over and over again each time (not what I want). Now I could kill the workerthread when I lose the connection and start a new one but this seems like a waste of resources. What I really want to do, is marshal the call (i.e., my thread start method) back to the thread that is still in memory although not doing anything. Please post any examples or docs you have that would be of use. Thanks.

    Read the article

  • Print raw data to a thermal-printer using .NET

    - by blauesocke
    I'm trying to print out raw ascii data to a thermal printer. I do this by using this code example: http://support.microsoft.com/kb/322091 but my printer prints always only one character and this not until I press the form feed button. If I print something with notepad the printer will do a form feed automatically but without printing any text. The printer is connected via usb over a lpt2usb adapter and Windows 7 uses the "Generic - Generic / Text Only" driver. Anyone knows what is going wrong? How is it possible to print some words and do some form feeds? Are there some control characters I have to send? And if yes: How do I send them? Edit 14.04.2010 21:51 My code (C#) looks like this: PrinterSettings s = new PrinterSettings(); s.PrinterName = "Generic / Text Only"; RawPrinterHelper.SendStringToPrinter(s.PrinterName, "Test"); This code will return a "T" after I pressed the form feed button (This litte black button here: swissmania.ch/images/935-151.jpg - sorry, not enough reputation for two hyperlinks) Edit 15.04.2010 16:56 I'm using now the code form here: c-sharpcorner.com/UploadFile/johnodonell/PrintingDirectlytothePrinter11222005001207AM/PrintingDirectlytothePrinter.aspx I modified it a bit that I can use the following code: byte[] toSend; // 10 = line feed // 13 carriage return/form feed toSend = new byte[1] { 13 }; PrintDirect.WritePrinter(lhPrinter, toSend, toSend.Length, ref pcWritten); Running this code has the same effekt like pressing the form feed button, it works fine! But code like this still does not work: byte[] toSend; // 10 = line feed // 13 carriage return/form feed toSend = new byte[2] { 66, 67 }; PrintDirect.WritePrinter(lhPrinter, toSend, toSend.Length, ref pcWritten); This will print out just a "B" but I expect "BC" and after running any code I have to reconnect the USB cable to make it work agian. Any ideas?

    Read the article

  • How to prevent buffer overflow in C/C++?

    - by alexpov
    Hello, i am using the following code to redirect stdout to a pipe, then read all the data from the pipe to a buffer. I have 2 problems: first problem: when i send a string (after redirection) bigger then the pipe's BUFF_SIZE, the program stops responding (deadlock or something). second problem: when i try to read from a pipe before something was sent to stdout. I get the same response, the program stops responding - _read command stuck's ... The issue is that i don't know the amount of data that will be sent to the pipe after the redirection. The first problem, i don't know how to handle and i'll be glad for help. The second problem i solved by a simple workaround, right after the redirection i print space character to stdout. but i guess that this solution is not the correct one ... #include <fcntl.h> #include <io.h> #include <iostream> #define READ 0 #define WRITE 1 #define BUFF_SIZE 5 using namespace std; int main() { int stdout_pipe[2]; int saved_stdout; saved_stdout = _dup(_fileno(stdout)); // save stdout if(_pipe(stdout_pipe,BUFF_SIZE, O_TEXT) != 0 ) // make a pipe { exit(1); } fflush( stdout ); if(_dup2(stdout_pipe[1], _fileno(stdout)) != 0 ) //redirect stdout to the pipe { exit(1); } ios::sync_with_stdio(); setvbuf( stdout, NULL, _IONBF, 0 ); //anything sent to stdout goes now to the pipe //printf(" ");//workaround for the second problem printf("123456");//first problem char buffer[BUFF_SIZE] = {0}; int nOutRead = 0; nOutRead = _read(stdout_pipe[READ], buffer, BUFF_SIZE); //second problem buffer[nOutRead] = '\0'; // reconnect stdout if (_dup2(saved_stdout, _fileno(stdout)) != 0 ) { exit(1); } ios::sync_with_stdio(); printf("buffer: %s\n", buffer); } Thanks, Alex

    Read the article

  • SignalR - Handling disconnected users

    - by guilhermeGeek
    Hy, I'm using the signalR library on a project to handle an notification and chat modules. I've a table on an database to keep a track of online users. The HUB for chat is inheriting IDisconnect where i disconnect the user. After disconnecting the user, i warm the users about that event. At this point, i check if the disconnect user is the client. If it's, then i call an method on HUB to reconnect the user (just update the table). I do this because with the current implementation, once the user closes a tab on the browser it calls the Disconnect task but he could have another tab opened. I've not tested (with larger requests) this module yet, but on my development server it could take a few seconds between the IDisconnect event, and the request from the user to connect again. I'm concerned with my implementation to handle disconnected users from the chat but i can't see another way to improve this. If possible, could someone give me a advice on this, or this is the only solution that i've?

    Read the article

  • jquery-sortable using behavior of a linkedlist

    - by BabaBooey
    I suspect I'm not looking at this issue in the right way so here goes. I have essentially a LinkedList of data on a web page (http://en.wikipedia.org/wiki/Linked_list) that I'd like to manipulate using traditional Linked List behavior (i.e. just updating the reference/id of the "next" object) for performance reasons. Where this gets a bit tricky is I'd ideally like to use Jquery's sortable to do this. Like the user would drag something up/down and I could just do an Ajax call to the server with the id of the object that moved and the new parent id of that object (and then behind the scenes I could figure out how to reconnect things..maybe need more data than that...). But every example I've seen where sortable is used they were sending the whole re-indexed list to the database to update which seems unnecessary to me. With a linked list to change an element's "index" I only need to make 3 updates which depending on the size of the list could be a big performance savings. Anyone have an example of what I'm trying to do...am I too far in left field?

    Read the article

  • Why is this SocketException not caught by a generic catch routine?

    - by Tarnschaf
    Our company provides a network component (DLL) for a GUI application. It uses a Timer that checks for disconnections. If it wants to reconnect, it calls: internal void timClock_TimerCallback(object state) { lock (someLock) { // ... try { DoConnect(); } catch (Exception e) { // Log e.Message omitted // Raise event with e as parameter ErrorEvent(this, new ErrorEventArgs(e)); DoDisconnect(); } // ... } } So the problem is, inside of the DoConnect() routine a SocketException is thrown (and not caught). I would assume, that the catch (Exception e) should catch ALL exceptions but somehow the SocketException was not caught and shows up to the GUI application. protected void DoConnect() { // client = new TcpClient(); client.NoDelay = true; // In the following call the SocketException is thrown client.Connect(endPoint.Address.ToString(), endPoint.Port); // ... (login stuff) } The doc confirmed that SocketException extends Exception. The stacktrace that showed up is: TcpClient.Connect() -> DoConnect() -> timClock_TimerCallback So the exception is not thrown outside the try/catch block. Any ideas why it doesn't work?

    Read the article

  • Does Java 6 open a default port for JMX remote connections?

    - by Bob Cross
    My specific question has to do with JMX as used in JDK 1.6: if I am running a Java process using JRE 1.6 with com.sun.management.jmxremote in the command line, does Java pick a default port for remote JMX connections? Backstory: I am currently trying to develop a procedure to give to a customer that will enable them to connect to one of our processes via JMX from a remote machine. The goal is to facillitate their remote debugging of a situation occurring on a real-time display console. Because of their service level agreement, they are strongly motivated to capture as much data as possible and, if the situation looks too complicated to fix quickly, to restart the display console and allow it to reconnect to the server-side. I am aware the I could run jconsole on JDK 1.6 processes and jvisualvm on post-JDK 1.6.7 processes given physical access to the console. However, because of the operational requirements and people problems involved, we are strongly motivated to grab the data that we need remotely and get them up and running again. EDIT: I am aware of the command line port property com.sun.management.jmxremote.port=portNum The question that I am trying to answer is, if you do not set that property at the command line, does Java pick another port for remote monitoring? If so, how could you determine what it might be?

    Read the article

  • How can I diagnose "Cannot determine peer address" in my Perl TCP script?

    - by MadBoy
    I've this little script which does it's job pretty well but sometimes it tends to fail. It fails in 2 cases: with error send: Cannot determine peer address at ./tcp-new.pl line 52 with no output or anything, it just fails to deliver what it got to connected Tcp Client. Usually it happens after I disconnect from server, go home and connect it again. To fix this restart is required and it starts working. Sometimes this problem is followed by problem mentioned in point 1. Note: it's not problem when I disconnect and reconnect to it again within short amount of time (unless error nr 1 happens). So can anyone help me make this code be a bit more stable so I don't have to restart it every day? #!/usr/bin/perl use strict; use warnings; use IO::Socket; use IO::Select; my $tcp_port = "10008"; my $udp_port = "2099"; my $tcp_socket = IO::Socket::INET->new( Listen => SOMAXCONN, LocalPort => $tcp_port, Proto => 'tcp', ReuseAddr => 1, ); my $udp_socket = IO::Socket::INET->new( LocalPort => $udp_port, Proto => 'udp', ); my $read_select = IO::Select->new(); my $write_select = IO::Select->new(); $read_select->add($tcp_socket); $read_select->add($udp_socket); while (1) { my @read = $read_select->can_read(); foreach my $read (@read) { if ($read == $tcp_socket) { my $new_tcp = $read->accept(); $write_select->add($new_tcp); } elsif ($read == $udp_socket) { my $recv_buffer; $udp_socket->recv($recv_buffer, 1024, undef); my @write = $write_select->can_write(); foreach my $write (@write) { $write->send($recv_buffer); } } } }

    Read the article

  • Passive and active sockets

    - by davsan
    Quoting from this socket tutorial: Sockets come in two primary flavors. An active socket is con­nect­ed to a remote active socket via an open data con­nec­tion... A passive socket is not con­nect­ed, but rather awaits an in­com­ing con­nec­tion, which will spawn a new active socket once a con­nec­tion is es­tab­lished ... Each port can have a single passive socket binded to it, await­ing in­com­ing con­nec­tions, and mul­ti­ple active sockets, each cor­re­spond­ing to an open con­nec­tion on the port. It's as if the factory worker is waiting for new mes­sages to arrive (he rep­re­sents the passive socket), and when one message arrives from a new sender, he ini­ti­ates a cor­re­spon­dence (a con­nec­tion) with them by del­e­gat­ing someone else (an active socket) to ac­tu­al­ly read the packet and respond back to the sender if nec­es­sary. This permits the factory worker to be free to receive new packets. ... Then the tutorial explains that, after a connection is established, the active socket continues receiving data until there are no remaining bytes, and then closes the connection. What I didn't understand is this: Suppose there's an incoming connection to the port, and the sender wants to send some little data every 20 minutes. If the active socket closes the connection when there are no remaining bytes, does the sender have to reconnect to the port every time it wants to send data? How do we persist a once established connection for a longer time? Can you tell me what I'm missing here? My second question is, who determines the limit of the concurrently working active sockets?

    Read the article

  • Simple continuously running XMPP client in python

    - by tom
    I'm using python-xmpp to send jabber messages. Everything works fine except that every time I want to send messages (every 15 minutes) I need to reconnect to the jabber server, and in the meantime the sending client is offline and cannot receive messages. So I want to write a really simple, indefinitely running xmpp client, that is online the whole time and can send (and receive) messages when required. My trivial (non-working) approach: import time import xmpp class Jabber(object): def __init__(self): server = 'example.com' username = 'bot' passwd = 'password' self.client = xmpp.Client(server) self.client.connect(server=(server, 5222)) self.client.auth(username, passwd, 'bot') self.client.sendInitPresence() self.sleep() def sleep(self): self.awake = False delay = 1 while not self.awake: time.sleep(delay) def wake(self): self.awake = True def auth(self, jid): self.client.getRoster().Authorize(jid) self.sleep() def send(self, jid, msg): message = xmpp.Message(jid, msg) message.setAttr('type', 'chat') self.client.send(message) self.sleep() if __name__ == '__main__': j = Jabber() time.sleep(3) j.wake() j.send('[email protected]', 'hello world') time.sleep(30) The problem here seems to be that I cannot wake it up. My best guess is that I need some kind of concurrency. Is that true, and if so how would I best go about that? EDIT: After looking into all the options concerning concurrency, I decided to go with twisted and wokkel. If I could, I would delete this post.

    Read the article

  • Deleting a node from linked list in C

    - by LuckySlevin
    My problem is deleting a node from linked list. I have two structs : typedef struct inner_list { int count; char word[100]; inner_list*next; } inner_list; typedef struct outer_list { char word [100]; inner_list * head; int count; outer_list * next; } outer_list; My problem is in deleting a node from outer_list linked list. For example when user entered aaa to delete, delete function should find the node with outer_list->word = aaa and delete this node and reconnect the list again. I tried the below code to do this. but After finding and deleting I'm losing the list. I don't know what's wrong. Please notice that outer_list have also a linked list of inner_list inside. void delnode(outer_list *head,char num[100]) { outer_list *temp, *m; temp=head; while(temp!=NULL) { if(strcmp(temp->word==num)==0) { if(temp==head) { head=temp->next; free(temp); return; } else { m->next=temp->next; free(temp); return; } }else { m=temp; temp= temp->next; } } printf(" ELEMENT %s NOT FOUND ", num); } What are your ideas about this?