Search Results

Search found 2489 results on 100 pages for 'hp laserjet'.

Page 27/100 | < Previous Page | 23 24 25 26 27 28 29 30 31 32 33 34  | Next Page >

  • Disable a Section of the Mousepad?

    - by Shahmeer Navid
    I purchased a hp envy 4 ultrabook. Its great but I'm infuriated at the touchpad. The click buttons and the touch pad are combined together but the click button area is touch sensitive. I usually rest my thumb on the right click but the mouse cursor goes completely crazy on this machine. Is there any way to disable a section of the touchpad? Basically make the click button area have nothing to do with the pointer function. I did see this post: Disable touch pad for mouse button region on new HP pavillion models? but the solution presented in that only limited the area from which the touchpad can begin. Since I rest my thumb on the click buttons, I would like to completely disable the click button area of the touchpad. Thank you.

    Read the article

  • VMWare - persistent "Host memory status" alarm in vSphere

    - by ewwhite
    I have a particular VMWare ESX 4.1 host that has a very persistent "Host memory status" alarm. This is running on an HP ProLiant DL360 G7 server. The HP ILO and System Management agents don't know any errors. If I clear the alarm in the vSphere client, it returns within a day. I've tried reseating DIMMs, however, the error does not indicate a problem with a specific module. There's another host in the cluster with an identical configuration. It's not exhibiting any issues. Any thoughts? This is touched on briefly on other forums (and here) with no clear resolution.

    Read the article

  • After installing Win7 on my laptop I'm having trouble extending the desktop to an external monitor

    - by devoured elysium
    I have a HP TX2000 laptop and a HP w2408 screen. Yesterday, I installed Win7 and I'm having trouble having the 24 inches screen work as a secondary screen. It seems like my laptop cannot detect both screens (its own and the 24 inches one). I think I already have all the drivers installed (I ran Win7's tool to detect and automatically update drivers and it said everything was up to date!), so what might be the problem? If I connect the 24 inch screen to my laptop, it will happily show a copy of what is being shown on that big screen too, but I'd like to have it ''extend'' the desktop to the big screen, instead.

    Read the article

  • Best Processor for MediaSmart Server?

    - by Kent Boogaart
    I'm trying to figure out what the best possible processor is that I can stick in my HP MediaSmart server. I'm clueless when it comes to correlating CPUs to motherboards. I suspect it's the socket type I care about, but I worry that there's more to it. CPU-Z gives me (excerpt): Processors Information ------------------------------------------------------------------------- Processor 1 ID = 0 Number of cores 1 (max 1) Number of threads 1 (max 1) Name AMD Sempron LE-1150 Codename Sparta Specification AMD Sempron(tm) Processor LE-1150 Package Socket AM2 (940) CPUID F.F.1 Extended CPUID F.7F Brand ID 1 Core Stepping DH-G1 Technology 65 nm Core Speed 1000.0 MHz Multiplier x FSB 5.0 x 200.0 MHz HT Link speed 800.0 MHz Stock frequency 2000 MHz Instructions sets MMX (+), 3DNow! (+), SSE, SSE2, SSE3, x86-64 L1 Data cache 64 KBytes, 2-way set associative, 64-byte line size L1 Instruction cache 64 KBytes, 2-way set associative, 64-byte line size L2 cache 256 KBytes, 16-way set associative, 64-byte line size FID/VID Control yes Max FID 10.0x Max VID 1.350 V P-State FID 0x2 - VID 0x12 (5.0x - 1.100 V) P-State FID 0xA - VID 0x0C (9.0x - 1.250 V) P-State FID 0xC - VID 0x0A (10.0x - 1.300 V) K8 Thermal sensor yes K8 Revision ID 6.0 Attached device PCI device at bus 0, device 24, function 0 Attached device PCI device at bus 0, device 24, function 1 Attached device PCI device at bus 0, device 24, function 2 Attached device PCI device at bus 0, device 24, function 3 Chipset ------------------------------------------------------------------------- Northbridge SiS 761GX rev. 02 Southbridge SiS 966 rev. 59 Graphic Interface AGP AGP Revision 3.0 AGP Transfer Rate 8x AGP SBA supported, enabled Memory Type DDR2 Memory Size 2048 MBytes Channels Single Memory Frequency 200.0 MHz (CPU/5) CAS# latency (CL) 5.0 RAS# to CAS# delay (tRCD) 5 RAS# Precharge (tRP) 5 Cycle Time (tRAS) 15 Bank Cycle Time (tRC) 21 Command Rate (CR) 1T DMI ------------------------------------------------------------------------- DMI BIOS vendor Phoenix Technologies, LTD version R03 date 05/08/2008 DMI System Information manufacturer HP product MediaSmart Server version unknown serial CN68330DGH UUID A482007B-B0CC7593-DD11736A-407B7067 DMI Baseboard vendor Wistron model SJD4 revision A.0 serial unknown DMI System Enclosure manufacturer HP chassis type Desktop chassis serial unknown DMI Processor manufacturer AMD model AMD Sempron(tm) Processor LE-1150 clock speed 2000.0 MHz FSB speed 200.0 MHz multiplier 10.0x DMI Memory Controller correction 64-bit ECC Max module size 4096 MBytes DMI Memory Module designation A0 size 2048 MBytes (double bank) DMI Memory Module designation A1 DMI Memory Module designation A2 DMI Memory Module designation A3 DMI Port Connector designation PS/2 Mouse (internal) port type Mouse Port connector PS/2 connector PS/2 DMI Port Connector designation USB0 (external) port type USB DMI Physical Memory Array location Motherboard usage System Memory correction None max capacity 16384 MBytes max# of devices 4 DMI Memory Device designation A0 format DIMM type unknown total width 64 bits data width 64 bits size 2048 MBytes DMI Memory Device designation A1 format DIMM type unknown total width 64 bits data width 64 bits DMI Memory Device designation A2 format DIMM type unknown total width 64 bits data width 64 bits DMI Memory Device designation A3 format DIMM type unknown total width 64 bits data width 64 bits How do I figure out what options I have for an upgrade?

    Read the article

  • Is proprietary vendor software required to use a wireless printer?

    - by sajee
    On Windows Vista, other than the driver, one can use a regular printer w/o any extra software, either plugged in via USB or over the network. I don't have to install extra software from the printer vendor to use the basic printer functionality. Is the same true for wireless printers? I need to install the HP 6000 wireless printer, and I hate installing vendor software other than the required drivers. So I'm wondering whether I need to install HP software on every PC that wants to use this printer? I haven't had a chance to read the manual but I'm hoping I don't have to. Can folks that have experience with wireless printers comment on whether vendor software, other than the printer driver, is required to use a wireless printer?

    Read the article

  • Admin mode on Procurve Switches

    - by stefan.at.wpf
    Not being a network expert, I spent some time configuring my network, until I found my mistake: On my HP ProCurve Switch 1810G, I thought that "Admin mode" means whether the administrative interface can be accessed from this port. Well, it means whether the port is enabled or not. Extract from the help function: Admin Mode - Select to enable the port-control administration state. Click to enable and have the port participate in the network.(Default : Enabled ) Well, of course I didn't read the help, because I didn't doubt it's for the adminsitrative interface and suspected an error somewhere else. Anyway, I am wondering if that is a commonly used term for enabling/disabling ports or if HP just wanted to make my life harder? I can't understand why this option isn't just called "Enable port"!? Here's a screenshot of how it looks in the web interface (yeah, shame on me for using a web interface)

    Read the article

  • Virtualization deployment for datacenter

    - by bogha
    Hi, my company is going to deploy an IT Infrastructure on a virtual platform, can you please help me with the following: 1- which one do you recommend, Cisco Unified computing system ( cisco + emc + vmware )or HP Blades( virtualization solution + HP Storage )? 2- i Need to install a DNS Server, Web server, cpanel for managing hosting packages and Microsoft layer of product for usingg in the corporate infrastructur ( active directory, Local DNS, Exchange server, DHCP, Global catalog ) what is the minimum requirments for these servers ( in terms of CPU and Memory ) . 3- what is the best way to implement a redundant solution in a virtual environment. thank you

    Read the article

  • Creating a vm using Hyper-V causes the host of BSOD

    - by Arcass
    Hi, Problem description: When I try to create a virtual machine, the host bsod part way through the process. From the logs in lookes to fail/hang on the "Creating new VirtualDisckDriver with new VHD" step. The BSOD error code is SYSTEM_SERVICE_EXCEPTION : STOP:0x0000003B When the machine has finished restarting, it looks to have created the vhd and XML files for the vm but it isn't accessable. I have two server bothing behaving in exactly the same way, so I don't believe it's a hardware fault. Has anyone had a similar experince? How did you resolve the problem? NOTES Hardware: HP DL380 G6 BIOS : 2010.03.30 (14 Apr 2010) [Latest from HP website] Inter Hyperthreading: Disabled Intel Virtuazation Technology : Enabled No-Execute Memory Protection: Enabled Mem check reports no errors OS: Windows 2008 Sp2 x64bit fully updated regards Arcass

    Read the article

  • Laptop hot after format

    - by Dany Khalife
    I recently formatted an HP G62 Laptop and installed all drivers from the HP site that should be installed for this model. But i noticed a very strange behavior, using Coretemp, the temp is always above 50 (on idle) and reaches 70 very quickly sometimes (Critical is 90) If i open youtube or skype alone, i can get temperatures as high as 83. Normally it was around 32 (on idle) and reaches 70 when i open games but not youtube.... I have a i3 processor and AMD graphics so i am wondering if somehow it's a graphics card issue (since i3 has integrated graphics as far as i know) Device manager shows only AMD graphics card tho, not sure if i3 graphics should appear here too. Any ideas what i might have forgotten to do after the format ?

    Read the article

  • Laptop hot after format

    - by Dany Khalife
    I recently formatted an HP G62 Laptop and installed all drivers from the HP site that should be installed for this model. But i noticed a very strange behavior, using Coretemp, the temp is always above 50 (on idle) and reaches 70 very quickly sometimes (Critical is 90) If i open youtube or skype alone, i can get temperatures as high as 83. Normally it was around 32 (on idle) and reaches 70 when i open games but not youtube.... I have a i3 processor and AMD graphics so i am wondering if somehow it's a graphics card issue (since i3 has integrated graphics as far as i know) Device manager shows only AMD graphics card tho, not sure if i3 graphics should appear here too. Any ideas what i might have forgotten to do after the format ?

    Read the article

  • data protector red tapes

    - by Caesar
    I am using HP Data Protector A.06.11 in my organization, with HP EML E-SeriesEML library, with 4 drives using LTO-4 tapes, and i am having some problems. Yesterday I put 5 new tapes in the robot and formatted them. At that time, the robot got just those empty 5 tapes with empty space. (all the rest of the tapes are red, or with protection) Today in the morning after the night (1 backup run at night), and 2 of the new tapes are red (the properties are): Writes : 2 Overwrites : 1 Errors : 9 I format one of them, and check for each drive if the tape become red, no one of the drives do it. In the main pool properties, in media condition got: Valid for : 36 (months) Maximum overwrites : 250

    Read the article

  • Broadcom HT1100 SATA controller not working properly with 1TB drives

    - by Jeff C
    I've been using RHEL distro's for several years and always managed to find the answers until now. I know this is more of a hardware issue, but I've been working on this for over a week and trust Linux and the IT community to help more then HP. I have CentOS 6.3 installed on an HP ProLiant DL145 G3 server with the BroadCom HT1100 IO controller and ServerWorks SATA Controller MMIO BIOS v3.0.0015.6 Firmware. This controller does not support large drives fully. Here's what I've tried and the results; Stock setup - Freezes on the ServerWorks POST screen. Can't even enter CMOS without disconnecting the drives. If I simply disconnect the SATA cables before it gets to the ServerWorks screen and reconnect afterwards I can boot from a CD, USB, PXE fine. However fiddling with cables at ever boot isn't practical. If I enter the BIOS config I can set it to not try booting the drives but leave the controller enabled. This lets me boot normally but the drives are not visible in the OS (live CDs or USB installed). I used method #2 to install and update CentOS. I have the /boot partition on a USB drive (everything else is on the SATA drives in software RAID1) hoping that would work around the issue but I get this Kernel panic - not syncing:Attempted to kill init! Pid: 1, comm: init Not tainted 2.6.32-279.9.1.el6.x86_6 #1 Call Trace: [<ffffffff814fd6ba>] ? panic+0xa0/0x168 [<ffffffff81070c22>] ? do_exit+0x862/0x870 [<ffffffff8117cdb5>] ? fput+0x25/0x30 [<ffffffff81070c88>] ? do_group_exit+0x58/0xd0 [<ffffffff81070d17>] ? sys_exit_group+0x17/0x20 [<ffffffff8100b0f2>] ? system_call_fastpath+0x16/0x1b panic occured, switching back to text console I'm sure it should be possible to talk to the drives without the BIOS boot check since the BIOS doesn't see them in method #2 either, their disconnected when it checks, but Linux sees them fine. If anyone could help figure out how I would greatly appreciate it! The other possible option I've come across is a complex firmware update. Tyan has a few boards on their website with the HT1100 and a ServerWorks v3.0.0015.7 update which says "adds support for TB drives" in the release notes. If someone could help me get the Tyan SATA firmware into the HP ROM file so I could just reflash that would also be very much appreciated. Thanks for any help you guys can offer!

    Read the article

  • esx 4 - c7000 - cisco 3020

    - by gdavid
    I have 4 blades with esx 4 installed in a HP c7000 enclosure. They have 6 cisco 3020 for hp switches in the backend. The plan was to use 2 switches for iSCSI traffic and the other 4 for data traffic. I am having a problem trunking the switches to our existing environment. The documentation i keep finding online has commands/features that are not available on the 3020 switch. Does anyone have this setup anywhere? I am looking to do Virtual Switch Tagging (VST) so i can control the machines vlan via the port groups. The only time any configuration worked for us was when our network team placed the command switchport native vlan x this setup only allowed vlan x to pass traffic and only when the port group was in vlan 0. Ideas? thanks for any help. -GD

    Read the article

  • Scrolling mouse sets windows sound volume

    - by Ikke
    Suddenly, when I use the scroll wheel of my mouse, it changes the windows sound volume level. I have a HP DV6-2030SD laptop with Windows 7 64 bit and a Zolid p50622 mouse. When I use the scroll function of the mouse pad of the laptop, it does not adjust the sound level. I don't have any special mouse drivers installed, just the standard windows drivers. When I scroll, I see the HP sound level screen: It doesn't do it always, but when it does, it prevents the current window to scroll, which is really annoying. Rebooting doesn't help. I've tried to put the USB dongle in a different port, but this doesn't help either. Any advise on how I can fix this?

    Read the article

  • Are the new Hewlett-Packard "Sandy Bridge"-based notebooks dispatched globally?

    - by leladax
    I'm currently trying to figure out why a European chain retailer is delaying a dv7 [remaining code number is not same with american]; it is listed in their site for several days and while ordered on Monday they still don't have it in their central storage. In an earlier call I was advised that since Intel announces the processor now it may start dispatching from the 6th. Is that true? Is HP obligated not to dispatch it before the 6th? (normally/legally or as a 'deal between gentlemen'). Does anyone know if HP dispatches normally dv7s now? Did they intentionally not dispatch them to retailers before the CES?

    Read the article

  • Laptop hot after format [migrated]

    - by Dany Khalife
    I recently formatted an HP G62 Laptop and installed all drivers from the HP site that should be installed for this model. But i noticed a very strange behavior, using Coretemp, the temp is always above 50 (on idle) and reaches 70 very quickly sometimes (Critical is 90) If i open youtube or skype alone, i can get temperatures as high as 83. Normally it was around 32 (on idle) and reaches 70 when i open games but not youtube.... I have a i3 processor and AMD graphics so i am wondering if somehow it's a graphics card issue (since i3 has integrated graphics as far as i know) Device manager shows only AMD graphics card tho, not sure if i3 graphics should appear here too. Any ideas what i might have forgotten to do after the format ?

    Read the article

  • how to record videos from my laptop webcam?

    - by Nick
    I am not sure but I can't seem to turn on my webcam to record videos which I would broad cast somewhere later on. I have a HP G62 Laptop, and the cam turns on when I use programs like Skype and other Video Calling clients, other wise I can't turn it own, as I don't seem to know how. Laptop: HP G62 Notebook PC, AMD Atholon II P230 Dual-Core, Windows 7: Home Premium Can some one tell me how do I turn on my webcam and record videos? Or is there some sort of a software? I tend to read stuff I wrote in Word, so if there is a program I need it to be in the tray dock and not to bug me, while I am moving between different documents/web pages.

    Read the article

  • Missing Driver - Video Controller (VGA Compatible)

    - by arahant
    I have a HP 2000-2106TU Notebook PC running Windows XP. I want to get the brightness keys to work. They are placed over the F2 and F3 buttons and are meant to be used in conjunction with the Fn key. But these combinations do not work, though other Fn keys such as the volume control keys do. I see a missing driver for a device called Video Controller (VGA Compatible) in the Windows Device Manager. The hardware id is PCI VEN 8086 DEV 0106 SUBSYS_1858103C which a Google search suggests is in an Intel HD Graphics family, but I don't know where to locate the driver. HP's driver scan does not help, as it does not show any missing driver related to video/graphics. What can I do next?

    Read the article

  • hp dl580 g5 diag error

    - by maruti
    server disk access is slow, and running insight diagnostics reports this error: Error: 640003 DST Error Error: 640006: The Read and/or Write HARD error rate is above threshold This drive has experienced/recorded error conditions reported by diagnosis and requires replacement"

    Read the article

  • Base system driver error - HP Pavilion Entertainment PC dv9323cl

    - by Damurph
    I upgraded to Wndows 7 and have a problem with graphics with my NVIDIA GeoForce Go 7600 not displaying properly. Also the Base System Drivers have yellow flags near them and it states that the The drivers for this device are not installed. (Code 28) There is no driver selected for the device information set or element. To find a driver for this device, click Update Driver. Any clues??? Please help!

    Read the article

  • HP ProCurve GVRP Setup

    - by Matt
    I'm trying to setup GVRP on my 4 ProCurve switches. Currently I have a Layer 3 3500yl-24G (J8692A) which is connected to 3 Layer 2 2510G-48 (J9280A). I have three trunk ports setup on the 3500 connected to the 3 switches and currently everything seems to be working, the devices are talking to eachother and GVRP is pushing its configurations from the 3500 to the 3 other switches. My question is, once GVRP is setup, how exactly do I configure the ports on the 3 L2 switches to use the correct VLAN? I'm new to ProCurve network equipment and this is much easier to setup on Cisco equipment.

    Read the article

  • Linksys SRW248g4p and hp procurves

    - by Garfield81
    We've got about 3 procurves linked up with about 5 linksys srw248g4p. Pinging between the Procurves I get ping time between 1-2 ms and pinging between the linksys the ping time are averaging 40 ms. I have evening tried pinging between two linksys switches that are connected to each other directly using the GB ports. There have no modification done to the switches and the firmware seems to be uptodate. Any suggestions would be appreciated.

    Read the article

  • Setup of HP ProCurve 2810-24G for iSCSI?

    - by 3molo
    Hi, I have a pair of ProCurve 2810-24G that I will use with a Dell Equallogic SAN and Vmware ESXi. Since ESXi does MPIO, I am a little uncertain on the configuration for links between the switches. Is a trunk the right way to go between the switches? I know that the ports for the SAN and the ESXi hosts should be untagged, so does that mean that I want tagged VLAN on the trunk ports? This is more or less the configuration: trunk 1-4 Trk1 Trunk snmp-server community "public" Unrestricted vlan 1 name "DEFAULT_VLAN" untagged 24,Trk1 ip address 10.180.3.1 255.255.255.0 no untagged 5-23 exit vlan 801 name "Storage" untagged 5-23 tagged Trk1 jumbo exit no fault-finder broadcast-storm stack commander "sanstack" spanning-tree spanning-tree Trk1 priority 4 spanning-tree force-version RSTP-operation The Equallogic PS4000 SAN has two controllers, with two network interfaces each. Dell recommends each controller to be connected to each of the switches. From vmware documentation, it seems creating one vmkernel per pNIC is recommended. With MPIO, this could allow for more than 1 Gbps throughput.

    Read the article

  • Setup VLAN agnostic ports on HP ProCurve 1810G (Ingress Filter, Trunking)

    - by Thomas
    I am wondering if it is possible to configure some ports of the web managed ProCurve Switch 1810G to participate in all VLAN traffic. Even if no VLAN with that ID has been set up inside the switch. The issue is that I have two virtualization servers that will use yet unknown VLANs of a certain range to communicate with each other. But the range is much larger than the 64 supported VLANs this switch can manage. The switch also offers static and LACP Link Trunks. But I guess there will also apply the Ingress Filter that drops packets with unconfigured VLAN IDs? A separate unmanaged switch that connects the two hosts and one ProCurve Port would work, but maybe I do not have to? Thanks

    Read the article

< Previous Page | 23 24 25 26 27 28 29 30 31 32 33 34  | Next Page >