  • Can hard drives experience magnetic interference from a server chassis?

    - by eek142
    I'm currently building a server, and it's exhibiting the weirdest behavior with the hard drive. It is a 2U case, and I have trouble trouble accessing the Seagate SATAIII hard drive when it is in the bottom slot of the hard drive cage. The case is made of galvanized/anodized steel. I thought the drive was DOA, but then I swapped it into the top slot, and the problem was solved--the system had no trouble recognizing the drive anymore! This got me thinking: Is it possible that the magnetic field from the chassis was affecting the hard drive's functionality? I only have this problem with the mechanical hard drive, not the SSD. Could it be because the chassis is made of steel? I'm baffled.

    Read the article

  • Considering building a new system; but undecided about chassis

    - by J.C. Bengtson
    I'm considering a new system build, and was thinking that this particular motherboard has features I need and like: http://www.tigerdirect.com/applications/searchtools/item-details.asp?EdpNo=667651&pagenumber=1&RSort=1&csid=ITD&recordsPerPage=5&body=REVIEWS#CustomerReviewsBlock .. but am unsure which model chassis to pair it with. I'd strongly prefer something from Cooler Master, as I'm a fan of their products, but am having a hard time deciding, and also don't want to get into some odd situation where the board doesn't properly fit. I plan on having two optical drives (5.25"), two internal HDs (3.5"), and will likely go with an SLI setup of 2 or possibly even 3 cards, so I'd need a chassis that is roomy enough to accomodate all of that, as well as the motherboard itself. Based on the stock available at that same site, do you all have any suggestions? The larger, the better, as I hate having components crammed together. Your help is most appreciated!

    Read the article

  • How can I measure actual memory usage from my running processes?

    - by NullUser
    I have two servers, server1 and server2. Both of them are identical HP blades, running the exact same OS (RHEL 5.5). Here's the output of free for both of them: ### server1: total used free shared buffers cached Mem: 8017848 2746596 5271252 0 212772 1768800 -/+ buffers/cache: 765024 7252824 Swap: 14188536 0 14188536 ### server2: total used free shared buffers cached Mem: 8017848 4494836 3523012 0 212724 3136568 -/+ buffers/cache: 1145544 6872304 Swap: 14188536 0 14188536 If I understand correctly, server2 is using significantly more memory for disk I/O caching, which still counts as memory used. But both are running the same OS and if I remember correctly, I configured both with the same parameters when they were installed. I did a diff on /etc/sysctl.conf and they are identical. The problem is, I am collecting memory usage and other metrics over a period of time, (eg: vmstat, iostat, etc.) while a load is generated on the system. The memory used for caching is throwing off my calculations on the results. How can I measure actual memory usage from my running processes, rather than system usage? Is used - (buffers + cached) a valid way to measure this?

    Read the article

  • How to make my SanDisk Cruzer Blade 4GB disk back to normal?

    - by Jack
    Currently, my SanDisk Cruzer Blade 4GB have become a 64MB Firebird RAW flash drive (thumb drive). I don't know why it become like this but when I plug it into a PC, it suddenly transform itself to become a 64MB flash drive. (From 4 GB to 64 MB, that is a huge change!) I read the following articles: http://forums.sandisk.com/t5/All-SanDisk-USB-Flash-Drives/Cruzer-Blade-will-not-format/td-p/214932 http://forums.whirlpool.net.au/archive/1691847 http://forum.hddguru.com/sandiskfirebird-64mb-t23539.html and notice that their solutions does not work at all. Some of their solution is as follows: Using the HP USB Disk Storage Format Tool (http://files.extremeoverclocking.com/file.php?f=1970), which did not work for me as it could not format. Using the h2testw to see if it is genuine, which did not work for me because it is a RAW partition. Return to the vendor, which I doubt since the product only have 1 year warranty and it has expired. I also notice that the flash drive is very fragile as after a few use, the flash drive have become something like the following: (The upper cover of the USB connector was broken or torn) So, wondering if someone have any good solution to fix it back so that at least I can retrieve my data on the fragile thumb drive.

    Read the article

  • Which Linux distributions work on IBM's JS20 PowerPC blade?

    - by Matthew Rankin
    Which Linux distributions have people successfully gotten working on an IBM JS20 Blade, which has the PowerPC 970 processor? Specifically, I'm interested in distributions other than RHEL and SLES. What gotchas need to be watched out for when installing a particular distribution of Linux on the JS20? Non-Specific Distribution Information IBM's Linux on BladeCenter JS20 IBM's eServer BladeCenter JS20 Whitepaper — "The JS20 blade supports all popular Linux distributions including Red Hat®, Inc., and SUSE LINUX." PenguinPPC Distributions List PPCLinux — "This project is a repository of information on how to run GNU/Linux on PowerPC architectures." Ubuntu Specific Information Ubuntu PowerPC FAQ — "Ubuntu 6.10 was the last officially supported PowerPC version of Ubuntu." Ubuntu PowerPC Download Ubuntu 8.04 PowerPC Supported Hardware Ubuntu 9.10 Ports — Mac (PowerPC) and IBM-PPC (POWER5) server install CD. For Apple Macintosh G3, G4, and G5 computers, including iBooks and PowerBooks as well as IBM OpenPower machines. Debian Specific Information Debian on PowerPC —"We may have a 64bit port in the future." Looks like there is only a 32-bit version available currently. Debian on JS20 blades Installing Debian Etch on IBM JS20s Gentoo Specific Information Gentoo Linux Crux PPC Specific Information Crux PPC

    Read the article

  • Oracle's Sun Blade modular systems: Can they give VBlock a run for their money?

    - by llaszews
    Check out these new hardware and software integrated solutions from Oracle Sun (they are not Exa* machines): http://www.oracle.com/us/products/servers-storage/servers/blades/index.html They offer a number of solutions not offered by VBlock: Oracle DB, Oracle WebLogic, OS and end to end management. Be interesting to see how much adoption these machines get given the long time VBlock has been around and the Exa* focused strategy at Oracle.

    Read the article

  • How would you apply a BIOS update for a Dell M610 blade with VMware ESXi installed?

    - by Guamaniac
    Hello, all. We've got a Dell M610 blade with VMware ESXi 4 installed and we need to update it's BIOS to the latest version. Unfortunately, Dell only makes available a Windows (.exe) and Linux (.bin) versions of the BIOS update program (as well as a bootable DOS floppy version that is too big to fit on a 1.44MB floppy!). We've tried using various "LiveCD" versions of linux distributions but keep running into errors. Anyone out there with experience with Dell blades who could give us a hint or two to get this working? Thanks a lot, in advance. Joe

    Read the article

  • IBM BladeCenter S: Disk Configuration

    - by gravyface
    Have just the one storage bay right now (SAS 15K 600GB x 6) and have configured one storage pool in RAID 10 with 4 disks (and two global spares). For each blade, I've created a volume and mapped accordingly: Blade #1 400 GB Blade #2 200 GB Blade #3 100 GB Blade #4 100 GB When I boot up Blade 1 and enter into the UEFI Setup (F1) followed by the Adapters and UEFI Drivers LSI Logic Fusion MPT SAS Driver Utility, I see 4 disks: two are the on-board 73GB drives, the other two are 200GB each and assume I'm being presented with two logical disks from the volume I created and mapped to this blade. I was a bit surprised by this: I figured I would've been presented with one logical drive per volume, not two. I'm assuming I can just configure whatever RAID level I wish that supports two disks, but not really sure what the benefits/trade-offs here. Should I go with RAID 10 on top of RAID 10? RAID 0? Software RAID 0/1/10? Does it even matter? If this is "normal" to see two disks, then I'm going to likely just do some benchmarking and see if it makes a difference changing the RAID levels (my guess is no); if this is not normal, well, please let me know. :)

    Read the article

  • SQL Clustering on Hyper V - is a cluster within a cluster a benefit.

    - by Chris W
    This is a re-hash of a question I asked a while back - after a consultant has come in firing ideas in to other teams in the department the whole issue has been raised again hence I'm looking for more detailed answers. We're intending to set-up a multi-instance SQL Cluster across a number of physical blades which will run a variety of different systems across each SQL instance. In general use there will be one virtual SQL instance running on each VM host. Again, in general operation each VM host will run on a dedicated underlying blade. The set-up should give us lots of flexibility for maintenance of any individual VM or underlying blade with all the SQL instances able to fail over as required. My original plan had been to do the following: Install 2008 R2 on each blade Add Hyper V to each blade Install a 2008 R2 VM to each blade Within the VMs - create a failover cluster and then install SQL Server clustering. The consultant has suggested that we instead do the following: Install 2008 R2 on each blade Add Hyper V to each blade Install a 2008 R2 VM to each blade Create a cluster on the HOST machines which will host all the VMs. Within the VMs - create a failover cluster and then install SQL Server clustering. The big difference is the addition of step 4 whereby we cluster all of the guest VMs as well. The argument is that it improves maintenance further since we have no ties at all between the SQL cluster and physical hardware. We can in theory live migrate the guest VMs around the hosts without affecting the SQL cluster at all so we for routine maintenance physical blades we move the SQL cluster around without interruption and without needing to failover. It sounds like a nice idea but I've not come across anything on the internet where people say they've done this and it works OK. Can I actually do the live migrations of the guests without the SQL Cluster hosted within them getting upset? Does anyone have any experience of this set up, good or bad? Are there some pros and cons that I've not considered? I appreciate that mirroring is also a valuable option to consider - in this case we're favouring clustering since it will do the whole of each instance and we have a good number of databases. Some DBs are for lumbering 3rd party systems that may not even work kindly with mirroring (and my understanding of clustering is that fail overs are completely transparent to the clients). Thanks.

    Read the article

  • python optparse, how to include additional info in usage output?

    - by CarpeNoctem
    Using python's optparse module I would like to add extra example lines below the regular usage output. My current help_print() output looks like this: usage: check_dell.py [options] options: -h, --help show this help message and exit -s, --storage checks virtual and physical disks -c, --chassis checks specified chassis components I would like it to include usage examples for the less *nix literate users at my work. Something like this: usage: check_dell.py [options] options: -h, --help show this help message and exit -s, --storage checks virtual and physical disks -c, --chassis checks specified chassis components Examples: check_dell -c all check_dell -c fans memory voltage check_dell -s How would I accomplish this? What optparse options allow for such? Current code: import optparse def main(): parser = optparse.OptionParser() parser.add_option('-s', '--storage', action='store_true', default=False, help='checks virtual and physical disks') parser.add_option('-c', '--chassis', action='store_true', default=False, help='checks specified chassis components') (opts, args) = parser.parse_args()

    Read the article

  • links for 2010-12-10

    - by Bob Rhubart
    Oracle VM Blade Cluster Reference Configuration (InfraRed) "All components listed in the reference configuration have been tested together by Oracle, reducing the need for customer testing and the time-consuming and complex effort of designing and deploying a stable configuration." -- Ferhat Hatay (tags: oracle virtualization clustering) White Paper: Accelerating Deployment of Virtualized Infrastructures with the Oracle VM Blade Cluster Reference Configuration  The Oracle VM blade cluster reference configuration described in this paper provides a complete and fully tested virtualized stack that can reduce deployment time by weeks or months while also reducing risk and improving application performance. (tags: oracle otn virtualization infrastructure) White Paper: Best Practices and Guidelines for Deploying the Oracle VM Blade Cluster Reference Configuration This paper provides recommendations and best practices for optimizing virtualization infrastructures when deploying the Oracle VM blade cluster reference configuration.  (tags: oracle otn virtualization clustering) Your Most Familiar Processes - Rethink before using E2.0 | Enterprise 2.0 Blogs "Imagine what gains your organization could have by asking basic questions and reviewing your familiar processes before setting up even the most fundamental E2.0 technologies to support them!" -- John Brunswick (tags: oracle enterprise2.0 otn) Oracle's Global Single Schema (Oracle Master Data Management) "The success of all business processes depends on the availability of accurate master data. Clearly, the solution to this problem is to consolidate all the master data an organization uses to run its business." -- David Butler (tags: oracle otn mdm entarch businessprocess) One step further towards proven results: IT Strategies from Oracle Oracle ACE Douwe Pieter van den Bos shares his thoughts on "IT Strategies from Oracle" in this Google translation of his original Dutch post. (tags: oracle itso entarch) The Underground Oracle VM Manual Just in time for the holidays! Roddy Rodstein's epic 354-page manual is now available in a single pdf.. (tags: oracle otn virtualization oraclevm)

    Read the article

  • Virutal Machine loses network connectivity on Hyper V

    - by Chris W
    We're running a number of VMs on a 6 node failover cluster of blades using Hyper V. We have an intermittent issue (every few days at different times - not a fixed frequency) of VMs losing network connectivity. Console access to the VM suggests all is fine and the underlying blade has normal connectivity. To resolve the problem we either have to re-start the VM or, more usually, we do a live migration to another blade which fires up connectivity and we then migrate it back to the original blade. I've had 3 instances of this happen with a specific VM running on a particular blade however it has happened once with a different VM running on a different blade. All VMs and blades have the same basic setup and are running Windows 2008 R2. Any ideas where I should be looking to diagnose the possible causes of this problem as the event logs provide no help?

    Read the article

  • Brocade 200E Switch - Fibre Channel

    - by Arthor
    What I have: Fujitsu-Siemens PRIMERGY BX600 Brocade 200E (16 port, 4gbit fibre). My question: Imagine a QNAP with a fiber 10GBIT card connected to the Brocade 200E (16 port, 4gbit fibre). Would this work; would the card drop down to 4GBIT? Are 10GBIT fiber cards backwards completable. Update. I have the specs of my server now.... Fujitsu-Siemens PRIMERGY BX600 S3 Blade Ecosystem Blade Chassis comprising; 2 x A3C40073243 Blade Management modules 2 x A3C40089238 GBE Switch Blade SB9F 30/12 2 x A3C40085736 4Gb 10 port pass through blades 1 x A3C40083767 Digital KVM Modules 2 x A3C40073245 Fan enclosures + cooling fans 4 x A3C40073262 Power Supplies My Goals and Objectives To have a blade system in place for 8 blades for video rendering, the other 2 for database and scripts etc The system will be built on VMWARE ESXi 5 Use ISCSI on the QNAP to support HA and vmotion if needed Users to access the qnap for video editing QANAP has 12 drive (2 x (6 HDD in RAID 10)

    Read the article

  • Virutal Machine loses network connectivity on Hyper V Cluster

    - by Chris W
    We're running a number of VMs on a 6 node failover cluster of blades using Hyper V. We have an intermittent issue (every few days at different times - not a fixed frequency) of VMs losing network connectivity. Console access to the VM suggests all is fine and the underlying blade has normal connectivity. To resolve the problem we either have to re-start the VM or, more usually, we do a live migration to another blade which fires up connectivity and we then migrate it back to the original blade. I've had 3 instances of this happen with a specific VM running on a particular blade however it has happened once with a different VM running on a different blade. All VMs and blades have the same basic setup and are running Windows 2008 R2. Any ideas where I should be looking to diagnose the possible causes of this problem as the event logs provide no help? Edit: I've checked that each blade is running the latest NIC drivers and all seem to be fine. Something that is confusing me - a failover or restart of the VM resolves the issue. Whilst I need to work out the underlying issue that is causing the NICs to hang I'm also concerned that the VM didn't failover to another node which would have solved the outage for me. Is there a way to configure the cluster so that it can tell that the VM guest has lost connectivity and fail it over? As things stand the cluster is assuming that the VM is running happily as I presume Hyper V says everything is great even though there is a problem.

    Read the article

  • Reset DRAC/MC password on Dell BladeCentre 1855

    - by Farseeker
    I have a Dell Blade Centre 1855, and nobody knows what the root password for the DRAC/MC card in the blade chassis is (I tried root/calvin). I do not have IP access to the DRAC/MC, nor do I have physical access to the back of the blade centre to access the DRAC/MC module. I do have serial access (and can see the login prompt in hyperterm). I do have physical access to the FRONT of the chassis (the back of the cabinet is locked and lo-and-behold the key cannot be found). Does anyone know how to reset the password? Every piece of literature I find on the internet tells me I need to log in, or run racadm on the host machine (which I can't, because it's inside a blade chassis). If someone does know how to do it with physical access to the back of the bladecentre, please post it anyway, as I'm sure I'll get access to the back of the cabinet one day)

    Read the article

  • Access property using its name in vb.net

    - by Aleksey
    For example: Sub Test() Dim car as new MyCar car.chassis.wheel.radius = 15 Console.WriteLine(car.chassis.wheel.radius) End Sub So question is. Is it possible to access the property using its string name like Something("car.chassis.wheel.radius") = 15?

    Read the article

  • LSI 9285-8e and Supermicro SC837E26-RJBOD1 duplicate enclosure ID and slot numbers

    - by Andy Shinn
    I am working with 2 x Supermicro SC837E26-RJBOD1 chassis connected to a single LSI 9285-8e card in a Supermicro 1U host. There are 28 drives in each chassis for a total of 56 drives in 28 RAID1 mirrors. The problem I am running in to is that there are duplicate slots for the 2 chassis (the slots list twice and only go from 0 to 27). All the drives also show the same enclosure ID (ID 36). However, MegaCLI -encinfo lists the 2 enclosures correctly (ID 36 and ID 65). My question is, why would this happen? Is there an option I am missing to use 2 enclosures effectively? This is blocking me rebuilding a drive that failed in slot 11 since I can only specify enclosure and slot as parameters to replace a drive. When I do this, it picks the wrong slot 11 (device ID 46 instead of device ID 19). Adapter #1 is the LSI 9285-8e, adapter #0 (which I removed due to space limitations) is the onboard LSI. Adapter information: Adapter #1 ============================================================================== Versions ================ Product Name : LSI MegaRAID SAS 9285-8e Serial No : SV12704804 FW Package Build: 23.1.1-0004 Mfg. Data ================ Mfg. Date : 06/30/11 Rework Date : 00/00/00 Revision No : 00A Battery FRU : N/A Image Versions in Flash: ================ BIOS Version : 5.25.00_4.11.05.00_0x05040000 WebBIOS Version : 6.1-20-e_20-Rel Preboot CLI Version: 05.01-04:#%00001 FW Version : 3.140.15-1320 NVDATA Version : 2.1106.03-0051 Boot Block Version : 2.04.00.00-0001 BOOT Version : 06.253.57.219 Pending Images in Flash ================ None PCI Info ================ Vendor Id : 1000 Device Id : 005b SubVendorId : 1000 SubDeviceId : 9285 Host Interface : PCIE ChipRevision : B0 Number of Frontend Port: 0 Device Interface : PCIE Number of Backend Port: 8 Port : Address 0 5003048000ee8e7f 1 5003048000ee8a7f 2 0000000000000000 3 0000000000000000 4 0000000000000000 5 0000000000000000 6 0000000000000000 7 0000000000000000 HW Configuration ================ SAS Address : 500605b0038f9210 BBU : Present Alarm : Present NVRAM : Present Serial Debugger : Present Memory : Present Flash : Present Memory Size : 1024MB TPM : Absent On board Expander: Absent Upgrade Key : Absent Temperature sensor for ROC : Present Temperature sensor for controller : Absent ROC temperature : 70 degree Celcius Settings ================ Current Time : 18:24:36 3/13, 2012 Predictive Fail Poll Interval : 300sec Interrupt Throttle Active Count : 16 Interrupt Throttle Completion : 50us Rebuild Rate : 30% PR Rate : 30% BGI Rate : 30% Check Consistency Rate : 30% Reconstruction Rate : 30% Cache Flush Interval : 4s Max Drives to Spinup at One Time : 2 Delay Among Spinup Groups : 12s Physical Drive Coercion Mode : Disabled Cluster Mode : Disabled Alarm : Enabled Auto Rebuild : Enabled Battery Warning : Enabled Ecc Bucket Size : 15 Ecc Bucket Leak Rate : 1440 Minutes Restore HotSpare on Insertion : Disabled Expose Enclosure Devices : Enabled Maintain PD Fail History : Enabled Host Request Reordering : Enabled Auto Detect BackPlane Enabled : SGPIO/i2c SEP Load Balance Mode : Auto Use FDE Only : No Security Key Assigned : No Security Key Failed : No Security Key Not Backedup : No Default LD PowerSave Policy : Controller Defined Maximum number of direct attached drives to spin up in 1 min : 10 Any Offline VD Cache Preserved : No Allow Boot with Preserved Cache : No Disable Online Controller Reset : No PFK in NVRAM : No Use disk activity for locate : No Capabilities ================ RAID Level Supported : RAID0, RAID1, RAID5, RAID6, RAID00, RAID10, RAID50, RAID60, PRL 11, PRL 11 with spanning, SRL 3 supported, PRL11-RLQ0 DDF layout with no span, PRL11-RLQ0 DDF layout with span Supported Drives : SAS, SATA Allowed Mixing: Mix in Enclosure Allowed Mix of SAS/SATA of HDD type in VD Allowed Status ================ ECC Bucket Count : 0 Limitations ================ Max Arms Per VD : 32 Max Spans Per VD : 8 Max Arrays : 128 Max Number of VDs : 64 Max Parallel Commands : 1008 Max SGE Count : 60 Max Data Transfer Size : 8192 sectors Max Strips PerIO : 42 Max LD per array : 16 Min Strip Size : 8 KB Max Strip Size : 1.0 MB Max Configurable CacheCade Size: 0 GB Current Size of CacheCade : 0 GB Current Size of FW Cache : 887 MB Device Present ================ Virtual Drives : 28 Degraded : 0 Offline : 0 Physical Devices : 59 Disks : 56 Critical Disks : 0 Failed Disks : 0 Supported Adapter Operations ================ Rebuild Rate : Yes CC Rate : Yes BGI Rate : Yes Reconstruct Rate : Yes Patrol Read Rate : Yes Alarm Control : Yes Cluster Support : No BBU : No Spanning : Yes Dedicated Hot Spare : Yes Revertible Hot Spares : Yes Foreign Config Import : Yes Self Diagnostic : Yes Allow Mixed Redundancy on Array : No Global Hot Spares : Yes Deny SCSI Passthrough : No Deny SMP Passthrough : No Deny STP Passthrough : No Support Security : No Snapshot Enabled : No Support the OCE without adding drives : Yes Support PFK : Yes Support PI : No Support Boot Time PFK Change : Yes Disable Online PFK Change : No PFK TrailTime Remaining : 0 days 0 hours Support Shield State : Yes Block SSD Write Disk Cache Change: Yes Supported VD Operations ================ Read Policy : Yes Write Policy : Yes IO Policy : Yes Access Policy : Yes Disk Cache Policy : Yes Reconstruction : Yes Deny Locate : No Deny CC : No Allow Ctrl Encryption: No Enable LDBBM : No Support Breakmirror : No Power Savings : Yes Supported PD Operations ================ Force Online : Yes Force Offline : Yes Force Rebuild : Yes Deny Force Failed : No Deny Force Good/Bad : No Deny Missing Replace : No Deny Clear : No Deny Locate : No Support Temperature : Yes Disable Copyback : No Enable JBOD : No Enable Copyback on SMART : No Enable Copyback to SSD on SMART Error : Yes Enable SSD Patrol Read : No PR Correct Unconfigured Areas : Yes Enable Spin Down of UnConfigured Drives : Yes Disable Spin Down of hot spares : No Spin Down time : 30 T10 Power State : Yes Error Counters ================ Memory Correctable Errors : 0 Memory Uncorrectable Errors : 0 Cluster Information ================ Cluster Permitted : No Cluster Active : No Default Settings ================ Phy Polarity : 0 Phy PolaritySplit : 0 Background Rate : 30 Strip Size : 64kB Flush Time : 4 seconds Write Policy : WB Read Policy : Adaptive Cache When BBU Bad : Disabled Cached IO : No SMART Mode : Mode 6 Alarm Disable : Yes Coercion Mode : None ZCR Config : Unknown Dirty LED Shows Drive Activity : No BIOS Continue on Error : No Spin Down Mode : None Allowed Device Type : SAS/SATA Mix Allow Mix in Enclosure : Yes Allow HDD SAS/SATA Mix in VD : Yes Allow SSD SAS/SATA Mix in VD : No Allow HDD/SSD Mix in VD : No Allow SATA in Cluster : No Max Chained Enclosures : 16 Disable Ctrl-R : Yes Enable Web BIOS : Yes Direct PD Mapping : No BIOS Enumerate VDs : Yes Restore Hot Spare on Insertion : No Expose Enclosure Devices : Yes Maintain PD Fail History : Yes Disable Puncturing : No Zero Based Enclosure Enumeration : No PreBoot CLI Enabled : Yes LED Show Drive Activity : Yes Cluster Disable : Yes SAS Disable : No Auto Detect BackPlane Enable : SGPIO/i2c SEP Use FDE Only : No Enable Led Header : No Delay during POST : 0 EnableCrashDump : No Disable Online Controller Reset : No EnableLDBBM : No Un-Certified Hard Disk Drives : Allow Treat Single span R1E as R10 : No Max LD per array : 16 Power Saving option : Don't Auto spin down Configured Drives Max power savings option is not allowed for LDs. Only T10 power conditions are to be used. Default spin down time in minutes: 30 Enable JBOD : No TTY Log In Flash : No Auto Enhanced Import : No BreakMirror RAID Support : No Disable Join Mirror : No Enable Shield State : Yes Time taken to detect CME : 60s Exit Code: 0x00 Enclosure information: # /opt/MegaRAID/MegaCli/MegaCli64 -encinfo -a1 Number of enclosures on adapter 1 -- 3 Enclosure 0: Device ID : 36 Number of Slots : 28 Number of Power Supplies : 2 Number of Fans : 3 Number of Temperature Sensors : 1 Number of Alarms : 1 Number of SIM Modules : 0 Number of Physical Drives : 28 Status : Normal Position : 1 Connector Name : Port B Enclosure type : SES VendorId is LSI CORP and Product Id is SAS2X36 VendorID and Product ID didnt match FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : 65 Inquiry data : Vendor Identification : LSI CORP Product Identification : SAS2X36 Product Revision Level : 0718 Vendor Specific : x36-55.7.24.1 Number of Voltage Sensors :2 Voltage Sensor :0 Voltage Sensor Status :OK Voltage Value :5020 milli volts Voltage Sensor :1 Voltage Sensor Status :OK Voltage Value :11820 milli volts Number of Power Supplies : 2 Power Supply : 0 Power Supply Status : OK Power Supply : 1 Power Supply Status : OK Number of Fans : 3 Fan : 0 Fan Speed :Low Speed Fan Status : OK Fan : 1 Fan Speed :Low Speed Fan Status : OK Fan : 2 Fan Speed :Low Speed Fan Status : OK Number of Temperature Sensors : 1 Temp Sensor : 0 Temperature : 48 Temperature Sensor Status : OK Number of Chassis : 1 Chassis : 0 Chassis Status : OK Enclosure 1: Device ID : 65 Number of Slots : 28 Number of Power Supplies : 2 Number of Fans : 3 Number of Temperature Sensors : 1 Number of Alarms : 1 Number of SIM Modules : 0 Number of Physical Drives : 28 Status : Normal Position : 1 Connector Name : Port A Enclosure type : SES VendorId is LSI CORP and Product Id is SAS2X36 VendorID and Product ID didnt match FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : 36 Inquiry data : Vendor Identification : LSI CORP Product Identification : SAS2X36 Product Revision Level : 0718 Vendor Specific : x36-55.7.24.1 Number of Voltage Sensors :2 Voltage Sensor :0 Voltage Sensor Status :OK Voltage Value :5020 milli volts Voltage Sensor :1 Voltage Sensor Status :OK Voltage Value :11760 milli volts Number of Power Supplies : 2 Power Supply : 0 Power Supply Status : OK Power Supply : 1 Power Supply Status : OK Number of Fans : 3 Fan : 0 Fan Speed :Low Speed Fan Status : OK Fan : 1 Fan Speed :Low Speed Fan Status : OK Fan : 2 Fan Speed :Low Speed Fan Status : OK Number of Temperature Sensors : 1 Temp Sensor : 0 Temperature : 47 Temperature Sensor Status : OK Number of Chassis : 1 Chassis : 0 Chassis Status : OK Enclosure 2: Device ID : 252 Number of Slots : 8 Number of Power Supplies : 0 Number of Fans : 0 Number of Temperature Sensors : 0 Number of Alarms : 0 Number of SIM Modules : 1 Number of Physical Drives : 0 Status : Normal Position : 1 Connector Name : Unavailable Enclosure type : SGPIO Failed in first Inquiry commnad FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : Unavailable Inquiry data : Vendor Identification : LSI Product Identification : SGPIO Product Revision Level : N/A Vendor Specific : Exit Code: 0x00 Now, notice that each slot 11 device shows an enclosure ID of 36, I think this is where the discrepancy happens. One should be 36. But the other should be on enclosure 65. Drives in slot 11: Enclosure Device ID: 36 Slot Number: 11 Drive's postion: DiskGroup: 5, Span: 0, Arm: 1 Enclosure position: 0 Device Id: 48 WWN: Sequence Number: 11 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SATA Raw Size: 2.728 TB [0x15d50a3b0 Sectors] Non Coerced Size: 2.728 TB [0x15d40a3b0 Sectors] Coerced Size: 2.728 TB [0x15d400000 Sectors] Firmware state: Online, Spun Up Is Commissioned Spare : YES Device Firmware Level: A5C0 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5003048000ee8a53 Connected Port Number: 1(path0) Inquiry Data: MJ1311YNG6YYXAHitachi HDS5C3030ALA630 MEAOA5C0 FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :30C (86.00 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Drive's write cache : Disabled Drive's NCQ setting : Enabled Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No Enclosure Device ID: 36 Slot Number: 11 Drive's postion: DiskGroup: 19, Span: 0, Arm: 1 Enclosure position: 0 Device Id: 19 WWN: Sequence Number: 4 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SATA Raw Size: 2.728 TB [0x15d50a3b0 Sectors] Non Coerced Size: 2.728 TB [0x15d40a3b0 Sectors] Coerced Size: 2.728 TB [0x15d400000 Sectors] Firmware state: Online, Spun Up Is Commissioned Spare : NO Device Firmware Level: A580 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5003048000ee8e53 Connected Port Number: 0(path0) Inquiry Data: MJ1313YNG1VA5CHitachi HDS5C3030ALA630 MEAOA580 FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :30C (86.00 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Drive's write cache : Disabled Drive's NCQ setting : Enabled Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No Update 06/28/12: I finally have some new information about (what we think) the root cause of this problem so I thought I would share. After getting in contact with a very knowledgeable Supermicro tech, they provided us with a tool called Xflash (doesn't appear to be readily available on their FTP). When we gathered some information using this utility, my colleague found something very strange: root@mogile2 test]# ./xflash.dat -i get avail Initializing Interface. Expander: SAS2X36 (SAS2x36) 1) SAS2X36 (SAS2x36) (50030480:00EE917F) (0.0.0.0) 2) SAS2X36 (SAS2x36) (50030480:00E9D67F) (0.0.0.0) 3) SAS2X36 (SAS2x36) (50030480:0112D97F) (0.0.0.0) This lists the connected enclosures. You see the 3 connected (we have since added a 3rd and a 4th which is not yet showing up) with their respective SAS address / WWN (50030480:00EE917F). Now we can use this address to get information on the individual enclosures: [root@mogile2 test]# ./xflash.dat -i 5003048000EE917F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:00EE917F Enclosure Logical Id: 50030480:0000007F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 [root@mogile2 test]# ./xflash.dat -i 5003048000E9D67F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:00E9D67F Enclosure Logical Id: 50030480:0000007F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 [root@mogile2 test]# ./xflash.dat -i 500304800112D97F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:0112D97F Enclosure Logical Id: 50030480:0112D97F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 Did you catch it? The first 2 enclosures logical ID is partially masked out where the 3rd one (which has a correct unique enclosure ID) is not. We pointed this out to Supermicro and were able to confirm that this address is supposed to be set during manufacturing and there was a problem with a certain batch of these enclosures where the logical ID was not set. We believe that the RAID controller is determining the ID based on the logical ID and since our first 2 enclosures have the same logical ID, they get the same enclosure ID. We also confirmed that 0000007F is the default which comes from LSI as an ID. The next pointer that helps confirm this could be a manufacturing problem with a run of JBODs is the fact that all 6 of the enclosures that have this problem begin with 00E. I believe that between 00E8 and 00EE Supermicro forgot to program the logical IDs correctly and neglected to recall or fix the problem post production. Fortunately for us, there is a tool to manage the WWN and logical ID of the devices from Supermicro: ftp://ftp.supermicro.com/utility/ExpanderXtools_Lite/. Our next step is to schedule a shutdown of these JBODs (after data migration) and reprogram the logical ID and see if it solves the problem. Update 06/28/12 #2: I just discovered this FAQ at Supermicro while Google searching for "lsi 0000007f": http://www.supermicro.com/support/faqs/faq.cfm?faq=11805. I still don't understand why, in the last several times we contacted Supermicro, they would have never directed us to this article :\

    Read the article

  • ipmi - can't ping or remotely connect

    - by Fidel
    I've tried configuring the IPMI controller to accept remote connections, but I can't even ping it. Here is it status: #/usr/local/bin/ipmitool lan print 2 Set in Progress : Set Complete Auth Type Support : NONE PASSWORD Auth Type Enable : Callback : : User : NONE PASSWORD : Operator : PASSWORD : Admin : PASSWORD : OEM : IP Address Source : Static Address IP Address : 192.168.1.112 Subnet Mask : 255.255.255.0 MAC Address : 00:a0:a5:67:45:25 IP Header : TTL=0x40 Flags=0x40 Precedence=0x00 TOS=0x10 BMC ARP Control : ARP Responses Enabled, Gratuitous ARP Enabled Gratituous ARP Intrvl : 8.0 seconds Default Gateway IP : 192.168.1.1 Default Gateway MAC : 00:00:00:00:00:00 802.1q VLAN ID : Disabled 802.1q VLAN Priority : 0 RMCP+ Cipher Suites : 0,1,2,3 Cipher Suite Priv Max : uaaaXXXXXXXXXXX : X=Cipher Suite Unused : c=CALLBACK : u=USER : o=OPERATOR : a=ADMIN : O=OEM # /usr/local/bin/ipmitool user list 2 ID Name Enabled Callin Link Auth IPMI Msg Channel Priv Limit 1 true false true true USER 2 admin true false true true ADMINISTRATOR # /usr/local/bin/ipmitool channel getaccess 2 2 Maximum User IDs : 5 Enabled User IDs : 2 User ID : 2 User Name : admin Fixed Name : No Access Available : callback Link Authentication : enabled IPMI Messaging : enabled Privilege Level : ADMINISTRATOR # /usr/local/bin/ipmitool channel info 2 Channel 0x2 info: Channel Medium Type : 802.3 LAN Channel Protocol Type : IPMB-1.0 Session Support : multi-session Active Session Count : 0 Protocol Vendor ID : 7154 Volatile(active) Settings Alerting : disabled Per-message Auth : disabled User Level Auth : disabled Access Mode : always available Non-Volatile Settings Alerting : disabled Per-message Auth : disabled User Level Auth : disabled Access Mode : always available # /usr/local/bin/ipmitool chassis status System Power : on Power Overload : false Power Interlock : inactive Main Power Fault : false Power Control Fault : false Power Restore Policy : unknown Last Power Event : Chassis Intrusion : inactive Front-Panel Lockout : inactive Drive Fault : false Cooling/Fan Fault : false # arp Address HWtype HWaddress Flags Mask Iface 192.168.1.112 ether 00:A0:A5:67:45:25 C bond0 # /usr/local/bin/ipmitool -I lan -H 192.168.1.112 -U admin -P admin chassis power status Error: Unable to establish LAN session Unable to get Chassis Power Status In summary. It exists on the ARP list so arp's are being broadcast. I can't ping it and can't connect to it. Can anyone spot any glaring mistakes in the configuration? Many thanks, Fidel

    Read the article

  • what is the fastest way to copy all data to a new larger hard drive?

    - by SUPER user
    I was certain this would have been covered before, but I cannot find an answer amongst all the almost-duplicates that come up; sorry if I've missed something obvious. I have a full 320gb disk inside my machine, a new 1tb disk to replace it, and a USB 2.0 chassis. It is only data on a single partition, no OS/apps involved, and the old drive will be kept somewhere as backup (no secure wiping etc). The simple option would be to put new disk in USB chassis, copy files, then swap them over. But for USB pen drives, reading is around 4x faster than writing. If the same is true for a USB SATA chassis (is it?) then it would be significantly faster to swap the drives first and read from the old drive over USB, right? Then the other consideration is that copying lots of files is usually slower than a single file of equivalent size. Is Windows 7 smart enough to do everything in a single lump like that, or is there specialised software that should be used instead? (Even if SATA-SATA copying is faster than involving USB, knowing what to do when it isn't an option is useful information.) Summary: Does a USB SATA chassis suffer from a read/write inequality? (like a USB pen drive does, but unlike a direct SATA connection) Can Windows 7 do sequential access? (I can't find confirmation if Robocopy does this.) Or is it necessary to use a bootable CD/USB with something like Clonezilla to achieve sequential copy speeds?

    Read the article

  • Using two joysticks in Cocos2D

    - by Blade
    Here is what I am trying to do: With the left joystick the player can steer the figure and with the right joystick it can attack. Problem is that the left joystick seems to get all the input, the right one does not even register anything. I enabled multipletouch after the eagleView and gone thoroughly over the code. But I seem to miss something. I initiliaze both sticks and it shows me both of them in game, but like I said, only the left one works. I initialize them both. From the h. file: SneakyJoystick *joystick; SneakyJoystick *joystickRight; And in m.file I synthesize, deallocate and initialize them. In order to use one for controlling and the other for attacking I put this: -(void)updateStateWithDeltaTime:(ccTime)deltaTime andListOfGameObjects:(CCArray*)listOfGameObjects { if ((self.characterState == kStateIdle) || (self.characterState == kStateWalkingBack) || (self.characterState == kStateWalkingLeft) || (self.characterState == kStateWalkingRight)|| (self.characterState == kStateWalkingFront) || (self.characterState == kStateAttackingFront) || (self.characterState == kStateAttackingBack)|| (self.characterState == kStateAttackingRight)|| (self.characterState == kStateAttackingLeft)) { if (joystick.degrees > 60 && joystick.degrees < 120) { if (self.characterState != kStateWalkingBack) [self changeState:kStateWalkingBack]; }else if (joystick.degrees > 1 && joystick.degrees < 59) { if (self.characterState != kStateWalkingRight) [self changeState:kStateWalkingRight]; } else if (joystick.degrees > 211 && joystick.degrees < 300) { if (self.characterState != kStateWalkingFront) [self changeState:kStateWalkingFront]; } else if (joystick.degrees > 301 && joystick.degrees < 360){ if (self.characterState != kStateWalkingRight) [self changeState:kStateWalkingRight]; } else if (joystick.degrees > 121 && joystick.degrees < 210) { if (self.characterState != kStateWalkingLeft) [self changeState:kStateWalkingLeft]; } if (joystickRight.degrees > 60 && joystickRight.degrees < 120) { if (self.characterState != kStateAttackingBack) [self changeState:kStateAttackingBack]; }else if (joystickRight.degrees > 1 && joystickRight.degrees < 59) { if (self.characterState != kStateAttackingRight) [self changeState:kStateAttackingRight]; } else if (joystickRight.degrees > 211 && joystickRight.degrees < 300) { if (self.characterState != kStateAttackingFront) [self changeState:kStateAttackingFront]; } else if (joystickRight.degrees > 301 && joystickRight.degrees < 360){ if (self.characterState != kStateAttackingRight) [self changeState:kStateAttackingRight]; } else if (joystickRight.degrees > 121 && joystickRight.degrees < 210) { if (self.characterState != kStateAttackingLeft) [self changeState:kStateAttackingLeft]; } [self applyJoystick:joystick forTimeDelta:deltaTime]; [self applyJoystick:joystickRight forTimeDelta:deltaTime]; } Maybe it has something to do with putting them both to time delta? I tried working around it, but it did not work. So I am thankful for any input you guys can give me :)

    Read the article

  • Cocos2D: Change animation based on joystick direction

    - by Blade
    I'm trying to get my figure to look in the right directions, based on the input of the joystick. So if I tilt left it looks left and the left animation is used, if I used right, it looks right and right animation is used, if up, then up, down, down and so on. I just get animation for front and back. Also if I press up I see the back of the figure correctly, but it won't go back into the original state when I don't press up anymore. -(void)applyJoystick:(SneakyJoystick *)aJoystick forTimeDelta:(float) deltaTime { CGPoint scaledVelocity = ccpMult(aJoystick.velocity, 128.0f); CGPoint oldPosition = [self position]; CGPoint newPosition = ccp(oldPosition.x + scaledVelocity.x * deltaTime, oldPosition.y + scaledVelocity.y * deltaTime); [self setPosition:newPosition]; id action = nil; int extra = 50; if ((int) aJoystick.degrees > 180 - extra && aJoystick.degrees < 180 + extra) { action = [CCAnimate actionWithAnimation:walkingAnimLeft restoreOriginalFrame:NO]; } else if ((int) aJoystick.degrees > 360 - extra && aJoystick.degrees < 360 + extra) { action = [CCAnimate actionWithAnimation:walkingAnimRight restoreOriginalFrame:NO]; } else if ((int) aJoystick.degrees > 90 - extra && aJoystick.degrees < 90 + extra) { action = [CCAnimate actionWithAnimation:walkingAnimBack restoreOriginalFrame:NO]; } else if ((int) aJoystick.degrees > 270 - extra && aJoystick.degrees < 270 + extra) { action = [CCAnimate actionWithAnimation:walkingAnimFront restoreOriginalFrame:NO]; } if (action != nil) { [self runAction:action]; } } }

    Read the article

  • Is there unreachable code in this snippet? I don't think so, but Resharper is telling me otherwise.

    - by The Matt
    I have the following method I came across in a code review. Inside the loop Resharper is telling me that if (narrativefound == false) is incorrect becuase narrativeFound is always true. I don't think this is the case, because in order to set narrativeFound to true it has to pass the conditional string compare first, so how can it always be true? Am I missing something? Is this a bug in Resharper or in our code? public Chassis GetChassisForElcomp(SPPA.Domain.ChassisData.Chassis asMaintained, SPPA.Domain.ChassisData.Chassis newChassis) { Chassis c = asMaintained; List<Narrative> newNarrativeList = new List<Narrative>(); foreach (Narrative newNarrative in newChassis.Narratives) { bool narrativefound = false; foreach (Narrative orig in asMaintained.Narratives) { if (string.Compare(orig.PCode, newNarrative.PCode) ==0 ) { narrativefound = true; if (newNarrative.NarrativeValue.Trim().Length != 0) { orig.NarrativeValue = newNarrative.NarrativeValue; newNarrativeList.Add(orig); } break; } if (narrativefound == false) { newNarrativeList.Add(newNarrative); } } } c.SalesCodes = newChassis.SalesCodes; c.Narratives = newNarrativeList; return c; }

    Read the article

  • BIOS upgrade lowers CPU temperature

    - by N.N.
    Setup I've got a system with an Asus P8Z68-V PRO motherboard and an Intel Core i7-2600K CPU running at stock speed (no overlocking) which I cool with a Noctua NH-U12P. On the heatsink I've got the two included fans connected via the included Low-Noise Adapters (L.N.A.) 1100 RPM, 16.9 dB(A). In the BIOS settings I've set the CPU and chassis fan profile to silent. Issue Yesterday I upgraded from BIOS version 0501 to 0606. After the upgrade I checked the temperatures in the BIOS monitor and was surprised to see that the CPU temperature was slightly ~30°C. Before the upgrade the CPU temperature was ~50°C with the same BIOS settings (see the following heading for details on temperatures). How can this be? It seems a bit odd that a BIOS upgrade can lower the CPU temperature by 20°C and it also seems odd that the CPU temperature is lower than the chassis temperature. Temperatures When I've checked temperatures the room temperature has been ~23°C. I haven't changed the placement of the computer nor the hardware or cooling setup between BIOS versions. BIOS version 0501 BIOS monitor: CPU: ~50°C Chassis: ~33°C I haven't got any temperature measures from lm-sensors or the like for version 0501 because I only discovered the issue after upgrading to version 0606 and the BIOS updater utility won't let me downgrade to version 0501 (it says "outdated image" when I try to load version 0501). BIOS version 0606 BIOS monitor: CPU: ~30°C Chassis: ~33°C lm-sensors in Ubuntu 11.04 Desktop 64-bit (sudo sensors after an uptime of 4 h 52 min and a load average of 0.22, 0.18, 0.15): coretemp-isa-0000 Adapter: ISA adapter Core 0: +32.0°C (high = +80.0°C, crit = +98.0°C) coretemp-isa-0001 Adapter: ISA adapter Core 1: +35.0°C (high = +80.0°C, crit = +98.0°C) coretemp-isa-0002 Adapter: ISA adapter Core 2: +29.0°C (high = +80.0°C, crit = +98.0°C) coretemp-isa-0003 Adapter: ISA adapter Core 3: +36.0°C (high = +80.0°C, crit = +98.0°C) The BIOS monitor temperatures was checked directly after the lm-sensors temperatures was checked. BIOS version 0706, 0801, 1101 and 3203 I get the same kind of temperatures both in the BIOS monitor and with lm-sensors in BIOS version 0706, 0801, 1101 and 3203 as in 0606. Information from Asus The 0606 changelog mentions nothing explicitly about CPU temperature (but item 3., as indicated by sidran32, might affect temperatures): P8Z68-V PRO 0606 BIOS with IRST 10.6.0.1002 Enable the support of Intel Rapid Storage Technology version 10.6.0.1002 Release Improve DRAM compatibility Improve System stability Improve compatibility with some Raid card model Increase IGD share memory size to 512MB However the following FAQ might give a hint: FAQs I find that the CPU temperature reading in BIOS is about 10~20 degrees centigrade hotter than the reading in OS. Is it normal? Page Tools Solution That is normal as BIOS does not send idle command to the CPU, making most of the power saving features useless. You should be getting similar reading if you disable EIST/C1E/CPU C3 Report/CPU C6 Report in BIOS.

    Read the article

  • VSS error 521 when attempting backup

    - by blade
    Hi, I have backupassist and I attempt to run a backup, with VSS service running. However, I get this error in Windows Event Log: The backup operation that started at '?2010?-?04?-?30T01:51:15.601000000Z' has failed because the Volume Shadow Copy Service operation to create a shadow copy of the volumes being backed up failed with following error code '2155348129'. Please review the event details for a solution, and then rerun the backup operation once the issue is resolved. Code: 521. The error in backupassist is: The backup operation stopped before completing. Detailed error: ERROR - A Volume Shadow Copy Service operation error has occurred: (0x80042336) The writer experienced a partial failure. Check the component level error state for more information. Log of files successfully backed up: C:\Windows\Logs\WindowsServerBackup\Backup-29-04-2010_18-51-15.log Log of files for which backup failed: C:\Windows\Logs\WindowsServerBackup\Backup_Error-29-04-2010_18-51-15.log A Volume Shadow Copy Service operation failed. Please check "VSS" and "SPP" application event logs for more information. ERROR - A Volume Shadow Copy Service operation error has occurred: (0x80042336) The writer experienced a partial failure. Check the component level error state for more information. Any idea how to fix this? I work in a company with server engineers, they all state of having no problems with 2008 and VSS (though in the company we use predominantly 2003). Without vss working, I assume no backup application will work? Thanks