  • hp ProLiant DL380 G6 server error code: 347 of array controller

    - by alhaythum
    I have got a bran new hp ProLiant DL380 G6 server with embedded smart array P410i controller, I got 164 GB SATA drives and wanted to change them with 300 GB SATA drives before installation. Now, we replace the drives and begin the configuration with the hp DVD and begin; when we reach the point that we want to save the configurations, an error message appears: "The operation has failed with an unknown error, please restart the application and attempt the operation again" When using Rescan System, this error message appears: "Status Alerts - Smart Array P410i in Embedded Slot Warning Status Message Code Description 347 The cache for Smart Array P410i Embedded Slot is not configured" We return back to the 164 GB SATA drives and the message just keeps appearing again. Any help please.

    Read the article

  • Cannot Start Nginx Compiled from Source

    - by Jason Alan Kennedy
    I am trying to compile Nginx from source based on the original compiled Nginx server running on my DigitalOcean server ( Ubuntu-14.04 64x ) but with a few extra modules. I can get everything installed smoothly but I can not get it to start. I am sure the ini is correct because I copied the original source off the current running Nginx server [ Even though I see that Nginx now adds the ini when compiling fron source ]. Below is the [ lengthy process ] that I am performing - add sorry but I wanted to be thorough for those who are in need of the info ]. Because I am a newB to Nginx, I am sure I am missing something or just have it all wrong. If you may look over what I have done and see if you spot anything I need/need to change, I will greatly appreciate it. Thnx! With the original Nginx server still running: I check the current/running Nginx configuration so I can build the new Nginx instance the same but with the added modules: nginx -V # The out-put: configure arguments: --with-cc-opt='-g -O2 -fstack-protector --param=ssp-buffer-size=4 -Wformat -Werror=format-security -D_FORTIFY_SOURCE=2' --with-ld-opt='-Wl,-Bsymbolic-functions -Wl,-z,relro' --prefix=/usr/share/nginx --conf-path=/etc/nginx/nginx.conf --http-log-path=/var/log/nginx/access.log --error-log-path=/var/log/nginx/error.log --lock-path=/var/lock/nginx.lock --pid-path=/run/nginx.pid --http-client-body-temp-path=/var/lib/nginx/body --http-fastcgi-temp-path=/var/lib/nginx/fastcgi --http-proxy-temp-path=/var/lib/nginx/proxy --http-scgi-temp-path=/var/lib/nginx/scgi --http-uwsgi-temp-path=/var/lib/nginx/uwsgi --with-debug --with-pcre-jit --with-ipv6 --with-http_ssl_module --with-http_stub_status_module --with-http_realip_module --with-http_addition_module --with-http_dav_module --with-http_geoip_module --with-http_gzip_static_module --with-http_image_filter_module --with-http_spdy_module --with-http_sub_module --with-http_xslt_module NOTE: The configure arguments below return errors during 'make' so I removed them. I don't know what they are - could this be related to my issue??? --with-cc-opt='-g -O2 -fstack-protector --param=ssp-buffer-size=4 -Wformat -Werror=format-security -D_FORTIFY_SOURCE=2' --with-ld-opt='-Wl,-Bsymbolic-functions -Wl,-z,relro' Moving on: # So I don't have to sudo every line: sudo bash # Check for updates first thing: apt-get update # Install various prerequisites needed to compile Nginx: apt-get install build-essential libgd2-xpm-dev lsb-base zlib1g-dev libpcre3 libpcre3-dev libbz2-dev libxslt1-dev libxml2 libssl-dev libgeoip-dev tar unzip openssl # Create System users [ if it doesn't exist - but I see its there on DigitalOceans' Droplets all-ready ]: adduser --system --no-create-home --disabled-login --disabled-password --group www-data # Download NGINX wget http://nginx.org/download/nginx-1.7.4.tar.gz tar -xvzf nginx-1.7.4.tar.gz # Then Google PageSpeed: wget https://github.com/pagespeed/ngx_pagespeed/archive/release-1.8.31.4-beta.zip unzip release-1.8.31.4-beta.zip # cd into the PageSpeed Directory cd ngx_pagespeed-release-1.8.31.4-beta/ # and add the PSOL files in there: wget https://dl.google.com/dl/page-speed/psol/1.8.31.4.tar.gz tar -xzvf 1.8.31.4.tar.gz # Get back to the root directory: cd # I add the ngx_cache_purge module and will install the Nginx Helper plugin for WP later: wget https://github.com/FRiCKLE/ngx_cache_purge/archive/2.1.zip unzip 2.1.zip # Add the headers-more-nginx-module: wget https://github.com/openresty/headers-more-nginx-module/archive/v0.25.zip unzip v0.25.zip # and the naxsi module for added security: wget https://github.com/nbs-system/naxsi/archive/0.53-2.tar.gz tar -xvzf 0.53-2.tar.gz # cd to the new Nginx directory cd nginx-1.7.4 # Set up the configuration build based on the current running Nginx config args and add my additional modules: ./configure \ --add-module=$HOME/naxsi-0.53-2/naxsi_src \ --prefix=/usr/share/nginx \ --conf-path=/etc/nginx/nginx.conf \ --http-log-path=/var/log/nginx/access.log \ --error-log-path=/var/log/nginx/error.log \ --lock-path=/var/lock/nginx.lock \ --pid-path=/run/nginx.pid \ --http-client-body-temp-path=/var/lib/nginx/body \ --http-fastcgi-temp-path=/var/lib/nginx/fastcgi \ --http-proxy-temp-path=/var/lib/nginx/proxy \ --http-scgi-temp-path=/var/lib/nginx/scgi \ --http-uwsgi-temp-path=/var/lib/nginx/uwsgi \ --user=www-data \ --group=www-data \ --with-debug \ --with-pcre-jit \ --with-ipv6 \ --with-http_ssl_module \ --with-http_stub_status_module \ --with-http_realip_module \ --with-http_addition_module \ --with-http_dav_module \ --with-http_geoip_module \ --with-http_gzip_static_module \ --with-http_image_filter_module \ --with-http_spdy_module \ --with-http_sub_module \ --with-http_xslt_module \ --with-mail \ --with-mail_ssl_module \ --add-module=$HOME/ngx_pagespeed-release-1.8.31.4-beta \ --add-module=$HOME/ngx_cache_purge-2.1 \ --add-module=$HOME/headers-more-nginx-module-0.25 [ENTER] Configuration Summary: Configuration summary + using system PCRE library + using system OpenSSL library + md5: using OpenSSL library + sha1: using OpenSSL library + using system zlib library nginx path prefix: "/usr/share/nginx" nginx binary file: "/usr/share/nginx/sbin/nginx" nginx configuration prefix: "/etc/nginx" nginx configuration file: "/etc/nginx/nginx.conf" nginx pid file: "/run/nginx.pid" nginx error log file: "/var/log/nginx/error.log" nginx http access log file: "/var/log/nginx/access.log" nginx http client request body temporary files: "/var/lib/nginx/body" nginx http proxy temporary files: "/var/lib/nginx/proxy" nginx http fastcgi temporary files: "/var/lib/nginx/fastcgi" nginx http uwsgi temporary files: "/var/lib/nginx/uwsgi" nginx http scgi temporary files: "/var/lib/nginx/scgi" Next step: I cd to root and I check the old Nginx folder locations and double checked the 'make' output to see that they are the same: whereis nginx #Output: nginx: /usr/sbin/nginx /etc/nginx /usr/share/nginx NOTE: Not sure about the '/usr/sbin/nginx' - Possible issue??? Next I copy the old /etc/nginx/nginx.conf, /etc/nginx/sites-available/default, /etc/nginx/sites-enabled/default, /etc/init.d/nginx to a text file locally for safe keeping to use in the new Nginx server. Then stop the running Nginx server: service nginx stop , verify it's stopped: service --status-all and the output is: [ - ] nginx To verify that there are two Nginx directories, I cd to: cd nginx* and the output is an error indicating there are two nginx folders - Cool Beans! :) Now Install the new Nginx server: cd nginx-1.7.4 make install # INSTALL OUTPUT ######################################## make -f objs/Makefile install make[1]: Entering directory `/home/walkingfish/nginx-1.7.4' test -d '/usr/share/nginx' || mkdir -p '/usr/share/nginx' test -d '/usr/share/nginx/sbin' || mkdir -p '/usr/share/nginx/sbin' test ! -f '/usr/share/nginx/sbin/nginx' || mv '/usr/share/nginx/sbin/nginx' '/usr/share/nginx/sbin/nginx.old' cp objs/nginx '/usr/share/nginx/sbin/nginx' test -d '/etc/nginx' || mkdir -p '/etc/nginx' cp conf/koi-win '/etc/nginx' cp conf/koi-utf '/etc/nginx' cp conf/win-utf '/etc/nginx' test -f '/etc/nginx/mime.types' || cp conf/mime.types '/etc/nginx' cp conf/mime.types '/etc/nginx/mime.types.default' test -f '/etc/nginx/fastcgi_params' || cp conf/fastcgi_params '/etc/nginx' cp conf/fastcgi_params '/etc/nginx/fastcgi_params.default' test -f '/etc/nginx/fastcgi.conf' || cp conf/fastcgi.conf '/etc/nginx' cp conf/fastcgi.conf '/etc/nginx/fastcgi.conf.default' test -f '/etc/nginx/uwsgi_params' || cp conf/uwsgi_params '/etc/nginx' cp conf/uwsgi_params '/etc/nginx/uwsgi_params.default' test -f '/etc/nginx/scgi_params' || cp conf/scgi_params '/etc/nginx' cp conf/scgi_params '/etc/nginx/scgi_params.default' test -f '/etc/nginx/nginx.conf' || cp conf/nginx.conf '/etc/nginx/nginx.conf' cp conf/nginx.conf '/etc/nginx/nginx.conf.default' test -d '/run' || mkdir -p '/run' test -d '/var/log/nginx' || mkdir -p '/var/log/nginx' test -d '/usr/share/nginx/html' || cp -R html '/usr/share/nginx' test -d '/var/log/nginx' || mkdir -p '/var/log/nginx' ######################################################### I copy/create the files that I saved earlier to txt files in sites-available, the config, default and ini files then symlink them to sites-enabled, and so on. And now to start the server: service nginx start And this is where s#!+ hits the fan - Nada. I check to see if Nginx is running with service --status-all and its not. Also with nginx -V and its not installed??? I reboot the system too and still nothing. So I am not sure what is wrong here. The ini was copied over from the old server along with all the other config files after deleting the old files. When I opened the new compiled files, the nginx default data was present so I replaced them with my old original data prior to starting the new server for the first time. Also to be safe, I rm /etc/nginx/sites-enabled/default and symlinked with ln -s /etc/nginx/sites-available/default /etc/nginx/sites-enabled/default with no errors and I verified that the data was in the sites-enabled/default file. I don't think the server really/fully installed because of the nginx -V result: The program 'nginx' can be found in the following packages: * nginx-core * nginx-extras * nginx-full * nginx-light * nginx-naxsi Try: apt-get install <selected package> Do/should I apt-get install nginx-1.7.4 ?? Or what package do I use being that its a custom package and make install earlier did nothing?? If you need to see the conf files I copied over from the old to the custom server, LMK and I'll post them. Again your help here would be appreciated!

    Read the article

  • FreeNas on Dell Powervault 745N: 2TB Limit?

    - by willoller
    I want to purchase 2 x 2TB drives, and install FreeNas on my Dell Powervault 745N. People on the internets seem to be having trouble with the MD3000 firmware, and I want to make sure I can solve any issues before buying the drives. Before I invest, I have 3 questions : Is there a partition size limit determined by the RAID controller? That is, could I have a striped 4TB partition? The spec sheets make me wonder if the RAID controller needs all 4 drives in order to work. Is there any reason this will have to run in RAID5? If I buy 4 matching drives, would the controller support a RAID6 configuration? I'm basically new to all this RAID stuff - sorry for any noob questions.

    Read the article

  • Permissions issue Mac OS X Client -> Mac OS X Server

    - by Meltemi
    I can't get access to a folder on our server and can't understand why. Perhaps someone will see what I'm overlooking... Trouble accessing /Library/Subdirectory/NextDirectory/ User joe can ssh to the server just fine and cd to /Library/Subdirectory/ however trying to cd into the next folder, NextDirectory, gives this error: -bash: cd: NextDirectory/: Permission denied both username joe & bill are members of the group admin and both can get INTO Subdirectory without any trouble... hostname:Library joe$ ls -l | grep Subdirectory drwxrwxr-x 3 bill admin 102 Jun 1 14:51 Subdirectory and from w/in the Subversion folder hostname:Subdirectory joe$ ls -l drwxrwx--- 5 root admin 170 Jun 1 22:19 NextDirectory bill can cd into NextDirectory but joe cannot!?! What am I overlooking? What tools do we have to troubleshoot this? thanks!

    Read the article

  • git problems installing stuff [closed]

    - by dale
    root@Frenzen:~# cd root@Frenzen:~# git clone --depth 1 git://source.ffmpeg.org/ffmpeg Initialized empty Git repository in /root/ffmpeg/.git/ root@Frenzen:~# cd root@Frenzen:~# git clone --depth 1 git://source.ffmpeg.org/ffmpeg Initialized empty Git repository in /root/ffmpeg/.git/ root@Frenzen:~# git clone git://source.ffmpeg.org/ffmpeg.git ffmpeg Initialized empty Git repository in /root/ffmpeg/.git/ cd root@Frenzen:~# wget "http://git.videolan.org/?p=ffmpeg.git;a=snapshot;h=HEAD;sf=tgz" -O ffmpeg-snapshot.tar.gz --2012-10-05 05:43:55-- http://git.videolan.org/?p=ffmpeg.git;a=snapshot;h=HEAD;sf=tgz Resolving git.videolan.org... 2a01:e0d:1:3:58bf:fa76:0:1, 88.191.250.118 Connecting to git.videolan.org|2a01:e0d:1:3:58bf:fa76:0:1|:80... root@Frenzen:~# cd root@Frenzen:~# wget "http://git.videolan.org/?p=ffmpeg.git;a=snapshot;h=HEAD;sf=tgz" -O ffmpeg-snapshot.tar.gz --2012-10-05 05:44:17-- http://git.videolan.org/?p=ffmpeg.git;a=snapshot;h=HEAD;sf=tgz Resolving git.videolan.org... 2a01:e0d:1:3:58bf:fa76:0:1, 88.191.250.118 Connecting to git.videolan.org|2a01:e0d:1:3:58bf:fa76:0:1|:80...

    Read the article

  • Delete until previous punctuation mark in Bash

    - by hekevintran
    In Bash, Ctrl + W will erase the last word. Bash considers words to be delimited by spaces. This means that if the cursor is at the end of the string "cd /dir1/dir2/dir3" and you hit Ctrl + W you will be left with "cd ". Is there a Bash shortcut (custom defined is okay) that will leave me with "cd /dir1/dir2/"?

    Read the article

  • Problems migrating software RAID 5 to new server (linux)

    - by leleu
    I have a CentOS setup with sw RAID5 that holds my data. Well, the server died, so I bought another box to migrate my drives to. Only thing is, I cannot get the RAID array rebuilt (not even sure it needs rebuilding, might just need the /dev/md0 mapping created... but I don't even know how to determine what I need!) Some details: RAID5 software (used mdadm) 4x 250GB drives (2 are SATA, 2 are EIDE -- would this matter? It worked fine in the other box...) latest CentOS distro built using mdadm I've got a decent amount of experience with standard linux stuff, but the hardware level stuff runs me in circles. I've spent some time googling and elsewhere here on SF, so please be kind for my newbie questions :). My question is this: how can I diagnose the problem? For all I know, I'm using the wrong device blocks when I try to rebuild the array, but I can't find the command to display only the devices that have some physical attachment. Is there some simple way for me to run mdadm, having it scan over all my physical drives, and say "hey, drives 2,5,6,7 are a software array, want me to mount it?" I basically just took the drives from my old box and put it into my new one. They show up in the BIOS. What steps do I need to take in order to get the array up, running, and mounted? Thanks in advance!

    Read the article

  • Debian and Multipath IO problem

    - by tearman
    Basically the situation is, I have a box running Debian, the box internally has an Intel SCSI RAID controller which is controlling 2 hard drives in RAID1 mode which is where the OS is installed. Further, I have a QLogic fiber channel adapter that connects the unit to a Fiber Channel SAN. My process of installation is I'll install Debian to the local drives, and leave the QLogic firmware out of it for the time being. Then once I get the unit online, I'll install the firmware drivers. This flops my internal drives from /dev/sda to /dev/sdc, which is a bit annoying, but recoverable. Probably should address these by UUID anyways. Once I get back online, I have to install multipath-tools (the framework is a multipath framework). However, once I reboot the machine again, it fails on boot after discovering multipath targets, saying my local drives are busy and cannot be mounted to /root. Any help in what may be the problem here? Or at least how to disable multipath until after the unit boots and then ignores the internal drives?

    Read the article

  • Can I set up a separate RAID 5 devices?

    - by GregH
    I have a GIGABYTE GA-P55M-UD2 motherboard in my system (Windows 7 64 bit) and currently have a Western Digital SATA 10k RPM drive in it. Is it possible to add three more SATA drives to make a single RAID 5 device that is separate from the current 10k rpm drive that I have in it? Once I enable RAID for the SATA drives, I am not required to make all of the drives part of the RAID volume am I? I can have separate RAID'ed and non-RAID'ed volumes can't I?

    Read the article

  • Why can't I navigate Active Directory within Powershell?

    - by Myrddin Emrys
    I have an AD: drive, which should allow me to browse active directory from within Powershell. But when I try to use it, it will not let me navigate beyond the root. From what I have read the given commands should work, but they are failing. PS AD:\> ls Name ObjectClass DistinguishedName ---- ----------- ----------------- company domainDNS DC=company,DC=com Configuration configuration CN=Configuration,DC=company,DC=com Schema dMD CN=Schema,CN=Configuration,DC=company,DC=com ForestDnsZones domainDNS DC=ForestDnsZones,DC=company,DC=com DomainDnsZones domainDNS DC=DomainDnsZones,DC=company,DC=com PS AD:\> cd schema Set-Location : Cannot find path 'AD:\schema' because it does not exist. At line:1 char:3 + cd <<<< schema + CategoryInfo : ObjectNotFound: (AD:\schema:String) [Set-Location], ItemNotFoundException + FullyQualifiedErrorId : PathNotFound,Microsoft.PowerShell.Commands.SetLocationCommand PS AD:\> cd Schema Set-Location : Cannot find path 'AD:\Schema' because it does not exist. (duplicate of previous error) PS AD:\> cd company Set-Location : Cannot find path 'AD:\company' because it does not exist. (duplicate of previous error) PS AD:\> ls Schema Get-ChildItem : Cannot find path '//RootDSE/Schema' because it does not exist. (duplicate of previous error) PS AD:\> cd ForestDnsZones Set-Location : Cannot find path 'AD:\ForestDnsZones' because it does not exist. (duplicate of previous error)

    Read the article

  • MD3200 - 3 to 4x less throughput than MD1220. Am I missing something here?

    - by Igor Polishchuk
    I have two R710 servers with similar configuration. One in my office has MD1220 attached. Another one in the datacenter of my hosting services vendor has MD3200. I'm getting significantly worse throughput from MD3200 at my vendors setup. I'm mostly interested in sequential writes, and I'm getting these results in bonnie++ and dd tests: Seq. writes on MD1220 in my office: 1.1 GB/s - bonnie++, 1.3GB/s - dd Seq. writes on MD3200 at my vendor's: 240MB/s - bonnie++, 310MB/s - dd Unfortunately, I could not test the exactly the same configurations, but the two I have should be comparable. If anything, my good performing environment is cheaper than the bad performing. I expect at least similar throughput from these two setups. My vendor cannot really help me. Hopefully, somebody more familiar with the DAS performance can look at it and tell if I'm missing something here and my expectations are too high. To summarize, the question here is it reasonable to expect about 100MB/s of sequential write throughput per each couple of drives in RAID10 on MD3200? Is there any trick to enable such performance in MD3200 with dual controller as opposed to simple MD1220 with a single H800 adapter? More details about the configurations: A good one in my office: Dell R710 2CPU X5650 @ 2.67GHz 12 cores 96GB DDR3, OS: RHEL 5.5, kernel 2.6.18-194.26.1.el5 x86_64 20x300GB 2.5" SAS 10K in a single RAID10 1MB chunk size on MD1220 + Dell H800 I/O controller with 1GB cache in the host Not so good one at my vendor's: Dell R710 2CPU L5520 @ 2.27GHz 8 cores 144GB DDR3, OS: RHEL 5.5, kernel 2.6.18-194.11.4.el5 x86_64 20x146GB 2.5" SAS 15K in a single RAID10 512KB chunk size, Dell MD3200, 2 I/O controllers in array with 1GB cache each Additional information. I've also ran the same tests on the same vendor's host, but the storage was: two raids of 14x146GB 15K RPM drives RAID 10, striped together on the OS level on MD3000+MD1000. The performance was about 25% worse than on MD3200 despite having more drives. When I ran similar tests on the internal storage of my vendor's host (2x146GB 15K RPM drives RAID1, Perc 6i) I've got about 128MB/s seq. writes. Just two internal drives gave me about a half of 20 drives' throughput on MD3200. The random I/O performance of the MD3200 setup is ok, it gives me at least 1300 IOPS. I'm mostly have problems with sequentioal I/O throughput. Thank you for looking into it. Regards Igor

    Read the article

  • HP DL380 RAID5 Mistake

    - by Eddy
    I had drives fail in both logical drives on a server. When I replaced failed 146GB drive in Raid 5 array with four (4) 146GB drives. On reboot the Smart Array controller asked if I wanted to accept data loss. Guess mistake to choose yes. Can't seem to find a way to get system to repair RAID5 but it seems to want to just create a new partition. Is there anyway I can go back and get the system to restore the data from other three drives now that I said accept data loss?

    Read the article

  • How do I get Windows 7 To Recognize a newly installed RAID 5 volume?

    - by GregH
    I had a previously running Windows 7 (64 bit) system. I added 3 new 1TB Seagate drives that I set up as a RAID 5 volume. I have a Gigabyte GA-P55M-UD2 motherboard. I installed the drives, set up the BIOS and configured the three drives as a RAID volume through the RAID setup utility that was accessed via Ctrl-I while the system was booting. I rebooted the system and could see the drives during the boot sequence. However, when Windows 7 was starting I got an error (quick blue screen) and then Windows tried to repair itself with no success. Do I need to install RAID drivers in Windows? How do I do it if Windows won't boot? Thanks in advance.

    Read the article

  • Installing SATA dvd burner on machine with no spare SATA ports/connectors

    - by Faheem Mitha
    Greetings. I have the following motherboard Tyan Thunder K8WE S2895A2NRF Motherboard - extended ATX - nForce Pro 2200/2050 - Socket 940 - UDMA133, Serial ATA-300 (RAID) - 2 x Gigabit Ethernet - FireWire - 6-1 channel audio This is part of a computer that was assembled in the winter of 2006/2007. The user manual says the following with regard to SATA Integrated SATAII Generation 1 Controllers (from NForce Professional 2200) Two integrated dual port SATA II controllers Four SATA connectors support up to four drives 3 Gb/s per direction per channel NvRAID v2.0 support Supports RAID 0, 1, 0+1 and JBOD. I just purchased a SATA DVD burner. Here is the page for the product http://www.amazon.ca/gp/product/B002QGDWLK/ The problem I am facing is that I already have 4 SATA drives installed. I don't want to remove any of them. However, I want the DVD burner above installed as well. The person I am consulting with here (Bombay, India) tells me that my four available SATA ports are filled, and that my only option is to install a SATA card into the one free PCI slot on the motherboard. However, he says that with this setup I will not be able to boot from the DVD drive. Are these statements correct, and what are my other options if any? Even it the statements in the last para are true, I suppose I could use one of the motherboard connectors/ports there are currently being used with the hard drives with the DVD drive, and use the "add-on" connector with one of the hard drives. Not all the 4 hard drives need to be bootable. BTW, despite having read through http://en.wikipedia.org/wiki/Serial_ATA#Cables.2C_connectors.2C_and_ports I am fuzzy on the differences between connectors, cables and ports. Thanks in advance.

    Read the article

  • RAID options for a LAMP web server

    - by jetboy
    I'm due to set up a LAMP web server with four drives and a RAID controller to act as a web server. The drives are 146Gb SAS, and the machine has two quad core processors and 16Gb RAM. There will be very few write operations to the MySQL database, and I'll be using as much caching as possible to reduce disk I/O. Question is: Would I be better off splitting the drives into two RAID 1 arrays, splitting up sequential and random disk I/O, or would I get better overall performance putting them all in a single RAID 1+0 array?

    Read the article

  • Raid-1 Western Digital Green AARS, cloning and WD Align Utility

    - by Jaguar
    Hello all, My current setup runs on top of 2x Western Digital 2500KS drives on Raid-1, using the motherboard's 780G raid controller, on WinXP. Everything is fine, but the drives are a bit noisy. I am considering buying 2x WD6400AARS disks which are the 640GB slower 'green' drives, but also feature the Advanced Formatting 4KB sectors. This means that for WinXP the partition will have to be aligned to work properly, else there is a performance penalty. There are 2 questions here: The Green drives from WD are all slower and are (according to WD) susceptible to drop-out's from the controller. Has anyone any experience in this matter? Is there a possibility the controller will drop a drive? If so, can i do anything about it? Secondly, western digital gives a utility to perform the alignment on the partition. The thing is, will the utility see the drives in question as the operating system only sees 1 logical disk? I will be making the transition using a cloning tool (most probably norton ghost) unless i don't find a solution or a clear answer, in which case i'll just buy a win 7 license and make a clean install... thx in advance

    Read the article

  • Windows 7 "Backup completed but some files were skipped"

    - by Andrew Coleson
    I set up Windows 7 Pro to backup my files to a network path (woohoo!) and chose to backup "data for newly created users, libraries", and my user folder (no system image). All went fine (although the first backup took ~12 hours for some ridiculous reason), but at the end it gave me a message that "Your backup completed, but some files were skipped. Click to see which files." I checked and the "files" skipped were my 3 network-mapped drives, which is perfectly fine and reasonable behavior (I certainly don't need it to back up my network-mapped drives as part of my local PC backup), but in the Backup and Restore center it warns me that my Last backup was "Never" and the Action Center now has a permanent "Check your backup results" issue. Is there any way to set up the backup to exclude the network-mapped drives or tell it that I really don't mind that it skipped drives I never asked it to back up?

    Read the article

  • How to do an automated installation of Ubuntu on 100 Remote machines?

    - by user40876
    Help!  I desperately need some advice / help... I want an automated install (via CD or USB) of Ubuntu 10.04 ...on 100 remote machines located all over the country, using a Kickstart configuration file accessible from my web server. How do I create the boot CD (or USB)? How do I specifically add the boot parameters to that boot CD (or USB) to tell it the URL to use for it's automated Kickstart install?

    Read the article

  • Deleting windows.edb and unchecking Indexing service lead to hard drive file records swapping

    - by linni
    I followed the instructions listed here:http://www.mydigitallife.info/2007/09/18/turn-off-and-disable-search-indexing-service-in-windows-xp/ to free up space on hard drive by deleting the windows.edb indexing file... I also stopped windows search service as mentioned in the comments following the article. In addition to unchecking the "Allow Indexing Service to index this disk for fast file searching" check box on the properties dialog for the C:\ drive, I did the same for two usb connected hard drives (J:\ and I:\ ). I'm not sure why I did that, thought it might shrink the windows.edb file so I wouldn't have to delete it (which sounded a bit risky in my ears at the time). The file of course didn't shrink so I ended up deleting it and freeing up over 3 GB of space, yeehaw. However, as soon as I had done this I could not access the usb connected hard drives anymore. The error I got was "I:\photos is not accessible" "The file or directory is corrupted and unreadable" when I tried to open the photos directory on I:\ Here is where I enter the twilight zone... I try disconnecting I:\ usb hard drive. But XP shows me that instead J:\ drive has disconnected and I:\ is still there. So I disconnect both drives and restart the computer. I then connect one drive, but it lists up the contents of the other drive on root level. I tried connecting the drives vice versa and the same thing happens. I try taking one of the hard drives to another computer and when I connect it there it lists up not its own contents but the contents of the other hard drive and gives the same error as above when I try and access any of the folders (even folders on the root that have the same name as folders on the other drive (e.g. J:\photos and I:\photos)??? And no, this is not a me mixing up my drive letters. Computer Manager - Disk management shows the same result as explorer: The drive size is correct (one is 500GB, the other is 640GB) but the drive name is of the opposite drive, as long as the contents. Also, one drive was full of data and the other almost empty but they incorrectly show their free space status of the other drive. Somehow the usb drives seem to have switched file tables, file records, boot records or something, extremely weird! Even weirder, if I try and create a text file or folder on this drive, it works fine, accessing them, saving, whatever, all good, but accessing any other data on the drive gives me an error. Does anyone have a clue what is going on and more importantly, how I can restore the correct folder listings to access my family photos ??? cheers, linni

    Read the article

  • Error message during installation of Windows XP Professional

    - by user270686
    During installation of Windows XP Professional the installer had an error which points to a bad CD, so I got another one and tried it, but the same thing happened. What can I do? It says: One of the components Windows needs to continue could not be installed.. The component is called: sys.dll D:/i386/asms/1000/msft/windows/gdiplus/gdiplus.man. I tried running chkdsk /f to fix the errors on the disk. I've searched the internet all day, and I don't know what else to do. I get this error message: SYS.DLL Syntax error in manifest or policy file D:/i386/asms/1000/msft/windows/gdiplus/gdiplus.man on line 4 Error Installation failed d:/I386/asms Error message Data Error (cyclic redundancy check) Fatal error One of the components Windows needs to continue could not be installed. If you are using a CD there might be a problem with the CD try cleaning it and trying again or using another CD.

    Read the article

  • I flashed my DS4700 with a 7 series firmware, now my DS4300 cannot read the disks I moved to that lo

    - by Daniel Hoeving
    In preparation for adding a number of 1Tb SATA disks to our DS4700 I flashed the controller firmware from a 6 series (which only supports up to 2Tb logical drives) to a 7 series (which supports larger than 2Tb logical drives). Attached to this DS4700 was a EXP710 expansion drawer that we had planned to migrate out to our co-location to allieviate the storage issues we were having there. Unfortunately these two projects were planned in isolation to one another so I was at the time unaware of the issue that this would cause. Prior to migrating the drawer I was reading the "IBM TotalStorage DS4000 EXP700 and EXP710 Storage Expansion EnclosuresInstallation, User’s, and Maintenance Guide" and discovered this: Controller firmware 6.xx or earlier has a different metadata (DACstore) data structure than controller firmware 7.xx.xx.xx. Metadata consists of the array and logical drive configuration data. These two metadata data structures are not interchangeable. When powered up and in Optimal state, the storage subsystem with controller firmware level 7.xx.xx.xx can convert the metadata from the drives configured in storage subsystems with controller firmware level 6.xx or earlier to controller firmware level 7.xx.xx.xx metadata data structure. However, the storage subsystem with controller firmware level 6.xx or earlier cannot read the metadata from the drives configured in storage subsystems with controller firmware level 7.xx.xx.xx or later. I had assumed that if I deleted the logical drives and array information on the EXP710 prior to migrating it to the DS4300 (6.60.22 firmware) this would satisfy the above, unfortunately I was wrong. So my question is a) Is it possible to restore the DAC information to its factory settings, b) What tool(s) would I use to accomplish this, or c) is this a lost cause? Daniel.

    Read the article

  • Can't change to Korean-named directory on my debian server

    - by DaLynX
    I made a rsync backup of some directories from a macbook laptop to a debian server. Some of these have korean characters (Hangeul) in their names. After fixing my server's locale, it displays well when I do a ls for instance. But I can't cd to it. Example: $ ls -1 | head ??? dirA dirB … But if try to go browse that directory: $ cd ? ? ? cd: 3: can't cd to ??? Any idea what's wrong and how to fix it ?

    Read the article

  • How do I protect business critical data against fire?

    - by Bill Knowles
    We have 72 hard drives that contain our webcast inventory. The number is increasing. We're located in a frame building and we are afraid of not only fire, but catastrophic fire. I've priced fireproof safes that hold to the required 125F for hard drives. Their price is through the roof. Seems to me if we made backups of each of the hard drives and stored them off-site somewhere, or contracted with an online backup storage company, we might run up a bill buying backup drives that would approach the $7,000 cost of the safe! What's the best way to protect our data from the risk of fire?

    Read the article

  • Installing Ubuntu to a USB drive

    - by Carl Smotricz
    I'm having a rough time getting Ubuntu to run from a 250 GB USB hard drive. I booted Ubuntu 9.10 from a CD and ran the regular "install" to the attached USB drive. I used the "advanced" option on the drive partition question to put the boot loader on /dev/sdb (the USB disk) but when I boot the machine it doesn't recognize there's a boot loader on the USB drive (it offers to boot from 2 other devices but not the USB disk). I also tried booting from the Ubuntu CD and using usb-creator-gtk to set up the USB drive. Seems to me this is meant to work with flash drives. I got a bootable USB disk but it looked and worked like the CD, i.e. it gave me options of "live CD" operation, installing, memtest, etc. That's not the way I want to run the system. Some help in installing Ubuntu, bootable into a "full" running system on my USB drive would be appreciated.

    Read the article

  • Deleting windows.edb and unchecking Indexing service lead to hard drive file records swapping

    - by linni
    I followed the instructions listed here:http://www.mydigitallife.info/2007/09/18/turn-off-and-disable-search-indexing-service-in-windows-xp/ to free up space on hard drive by deleting the windows.edb indexing file... I also stopped windows search service as mentioned in the comments following the article. In addition to unchecking the "Allow Indexing Service to index this disk for fast file searching" check box on the properties dialog for the C:\ drive, I did the same for two usb connected hard drives (J:\ and I:\ ). I'm not sure why I did that, thought it might shrink the windows.edb file so I wouldn't have to delete it (which sounded a bit risky in my ears at the time). The file of course didn't shrink so I ended up deleting it and freeing up over 3 GB of space, yeehaw. However, as soon as I had done this I could not access the usb connected hard drives anymore. The error I got was "I:\photos is not accessible" "The file or directory is corrupted and unreadable" when I tried to open the photos directory on I:\ Here is where I enter the twilight zone... I try disconnecting I:\ usb hard drive. But XP shows me that instead J:\ drive has disconnected and I:\ is still there. So I disconnect both drives and restart the computer. I then connect one drive, but it lists up the contents of the other drive on root level. I tried connecting the drives vice versa and the same thing happens. I try taking one of the hard drives to another computer and when I connect it there it lists up not its own contents but the contents of the other hard drive and gives the same error as above when I try and access any of the folders (even folders on the root that have the same name as folders on the other drive (e.g. J:\photos and I:\photos)??? And no, this is not a me mixing up my drive letters. Computer Manager - Disk management shows the same result as explorer: The drive size is correct (one is 500GB, the other is 640GB) but the drive name is of the opposite drive, as long as the contents. Also, one drive was full of data and the other almost empty but they incorrectly show their free space status of the other drive. Somehow the usb drives seem to have switched file tables, file records, boot records or something, extremely weird! Even weirder, if I try and create a text file or folder on this drive, it works fine, accessing them, saving, whatever, all good, but accessing any other data on the drive gives me an error. Does anyone have a clue what is going on and more importantly, how I can restore the correct folder listings to access my family photos ??? cheers, linni

    Read the article