  • LSI 9285-8e and Supermicro SC837E26-RJBOD1 duplicate enclosure ID and slot numbers

    - by Andy Shinn
    I am working with 2 x Supermicro SC837E26-RJBOD1 chassis connected to a single LSI 9285-8e card in a Supermicro 1U host. There are 28 drives in each chassis for a total of 56 drives in 28 RAID1 mirrors. The problem I am running in to is that there are duplicate slots for the 2 chassis (the slots list twice and only go from 0 to 27). All the drives also show the same enclosure ID (ID 36). However, MegaCLI -encinfo lists the 2 enclosures correctly (ID 36 and ID 65). My question is, why would this happen? Is there an option I am missing to use 2 enclosures effectively? This is blocking me rebuilding a drive that failed in slot 11 since I can only specify enclosure and slot as parameters to replace a drive. When I do this, it picks the wrong slot 11 (device ID 46 instead of device ID 19). Adapter #1 is the LSI 9285-8e, adapter #0 (which I removed due to space limitations) is the onboard LSI. Adapter information: Adapter #1 ============================================================================== Versions ================ Product Name : LSI MegaRAID SAS 9285-8e Serial No : SV12704804 FW Package Build: 23.1.1-0004 Mfg. Data ================ Mfg. Date : 06/30/11 Rework Date : 00/00/00 Revision No : 00A Battery FRU : N/A Image Versions in Flash: ================ BIOS Version : 5.25.00_4.11.05.00_0x05040000 WebBIOS Version : 6.1-20-e_20-Rel Preboot CLI Version: 05.01-04:#%00001 FW Version : 3.140.15-1320 NVDATA Version : 2.1106.03-0051 Boot Block Version : 2.04.00.00-0001 BOOT Version : 06.253.57.219 Pending Images in Flash ================ None PCI Info ================ Vendor Id : 1000 Device Id : 005b SubVendorId : 1000 SubDeviceId : 9285 Host Interface : PCIE ChipRevision : B0 Number of Frontend Port: 0 Device Interface : PCIE Number of Backend Port: 8 Port : Address 0 5003048000ee8e7f 1 5003048000ee8a7f 2 0000000000000000 3 0000000000000000 4 0000000000000000 5 0000000000000000 6 0000000000000000 7 0000000000000000 HW Configuration ================ SAS Address : 500605b0038f9210 BBU : Present Alarm : Present NVRAM : Present Serial Debugger : Present Memory : Present Flash : Present Memory Size : 1024MB TPM : Absent On board Expander: Absent Upgrade Key : Absent Temperature sensor for ROC : Present Temperature sensor for controller : Absent ROC temperature : 70 degree Celcius Settings ================ Current Time : 18:24:36 3/13, 2012 Predictive Fail Poll Interval : 300sec Interrupt Throttle Active Count : 16 Interrupt Throttle Completion : 50us Rebuild Rate : 30% PR Rate : 30% BGI Rate : 30% Check Consistency Rate : 30% Reconstruction Rate : 30% Cache Flush Interval : 4s Max Drives to Spinup at One Time : 2 Delay Among Spinup Groups : 12s Physical Drive Coercion Mode : Disabled Cluster Mode : Disabled Alarm : Enabled Auto Rebuild : Enabled Battery Warning : Enabled Ecc Bucket Size : 15 Ecc Bucket Leak Rate : 1440 Minutes Restore HotSpare on Insertion : Disabled Expose Enclosure Devices : Enabled Maintain PD Fail History : Enabled Host Request Reordering : Enabled Auto Detect BackPlane Enabled : SGPIO/i2c SEP Load Balance Mode : Auto Use FDE Only : No Security Key Assigned : No Security Key Failed : No Security Key Not Backedup : No Default LD PowerSave Policy : Controller Defined Maximum number of direct attached drives to spin up in 1 min : 10 Any Offline VD Cache Preserved : No Allow Boot with Preserved Cache : No Disable Online Controller Reset : No PFK in NVRAM : No Use disk activity for locate : No Capabilities ================ RAID Level Supported : RAID0, RAID1, RAID5, RAID6, RAID00, RAID10, RAID50, RAID60, PRL 11, PRL 11 with spanning, SRL 3 supported, PRL11-RLQ0 DDF layout with no span, PRL11-RLQ0 DDF layout with span Supported Drives : SAS, SATA Allowed Mixing: Mix in Enclosure Allowed Mix of SAS/SATA of HDD type in VD Allowed Status ================ ECC Bucket Count : 0 Limitations ================ Max Arms Per VD : 32 Max Spans Per VD : 8 Max Arrays : 128 Max Number of VDs : 64 Max Parallel Commands : 1008 Max SGE Count : 60 Max Data Transfer Size : 8192 sectors Max Strips PerIO : 42 Max LD per array : 16 Min Strip Size : 8 KB Max Strip Size : 1.0 MB Max Configurable CacheCade Size: 0 GB Current Size of CacheCade : 0 GB Current Size of FW Cache : 887 MB Device Present ================ Virtual Drives : 28 Degraded : 0 Offline : 0 Physical Devices : 59 Disks : 56 Critical Disks : 0 Failed Disks : 0 Supported Adapter Operations ================ Rebuild Rate : Yes CC Rate : Yes BGI Rate : Yes Reconstruct Rate : Yes Patrol Read Rate : Yes Alarm Control : Yes Cluster Support : No BBU : No Spanning : Yes Dedicated Hot Spare : Yes Revertible Hot Spares : Yes Foreign Config Import : Yes Self Diagnostic : Yes Allow Mixed Redundancy on Array : No Global Hot Spares : Yes Deny SCSI Passthrough : No Deny SMP Passthrough : No Deny STP Passthrough : No Support Security : No Snapshot Enabled : No Support the OCE without adding drives : Yes Support PFK : Yes Support PI : No Support Boot Time PFK Change : Yes Disable Online PFK Change : No PFK TrailTime Remaining : 0 days 0 hours Support Shield State : Yes Block SSD Write Disk Cache Change: Yes Supported VD Operations ================ Read Policy : Yes Write Policy : Yes IO Policy : Yes Access Policy : Yes Disk Cache Policy : Yes Reconstruction : Yes Deny Locate : No Deny CC : No Allow Ctrl Encryption: No Enable LDBBM : No Support Breakmirror : No Power Savings : Yes Supported PD Operations ================ Force Online : Yes Force Offline : Yes Force Rebuild : Yes Deny Force Failed : No Deny Force Good/Bad : No Deny Missing Replace : No Deny Clear : No Deny Locate : No Support Temperature : Yes Disable Copyback : No Enable JBOD : No Enable Copyback on SMART : No Enable Copyback to SSD on SMART Error : Yes Enable SSD Patrol Read : No PR Correct Unconfigured Areas : Yes Enable Spin Down of UnConfigured Drives : Yes Disable Spin Down of hot spares : No Spin Down time : 30 T10 Power State : Yes Error Counters ================ Memory Correctable Errors : 0 Memory Uncorrectable Errors : 0 Cluster Information ================ Cluster Permitted : No Cluster Active : No Default Settings ================ Phy Polarity : 0 Phy PolaritySplit : 0 Background Rate : 30 Strip Size : 64kB Flush Time : 4 seconds Write Policy : WB Read Policy : Adaptive Cache When BBU Bad : Disabled Cached IO : No SMART Mode : Mode 6 Alarm Disable : Yes Coercion Mode : None ZCR Config : Unknown Dirty LED Shows Drive Activity : No BIOS Continue on Error : No Spin Down Mode : None Allowed Device Type : SAS/SATA Mix Allow Mix in Enclosure : Yes Allow HDD SAS/SATA Mix in VD : Yes Allow SSD SAS/SATA Mix in VD : No Allow HDD/SSD Mix in VD : No Allow SATA in Cluster : No Max Chained Enclosures : 16 Disable Ctrl-R : Yes Enable Web BIOS : Yes Direct PD Mapping : No BIOS Enumerate VDs : Yes Restore Hot Spare on Insertion : No Expose Enclosure Devices : Yes Maintain PD Fail History : Yes Disable Puncturing : No Zero Based Enclosure Enumeration : No PreBoot CLI Enabled : Yes LED Show Drive Activity : Yes Cluster Disable : Yes SAS Disable : No Auto Detect BackPlane Enable : SGPIO/i2c SEP Use FDE Only : No Enable Led Header : No Delay during POST : 0 EnableCrashDump : No Disable Online Controller Reset : No EnableLDBBM : No Un-Certified Hard Disk Drives : Allow Treat Single span R1E as R10 : No Max LD per array : 16 Power Saving option : Don't Auto spin down Configured Drives Max power savings option is not allowed for LDs. Only T10 power conditions are to be used. Default spin down time in minutes: 30 Enable JBOD : No TTY Log In Flash : No Auto Enhanced Import : No BreakMirror RAID Support : No Disable Join Mirror : No Enable Shield State : Yes Time taken to detect CME : 60s Exit Code: 0x00 Enclosure information: # /opt/MegaRAID/MegaCli/MegaCli64 -encinfo -a1 Number of enclosures on adapter 1 -- 3 Enclosure 0: Device ID : 36 Number of Slots : 28 Number of Power Supplies : 2 Number of Fans : 3 Number of Temperature Sensors : 1 Number of Alarms : 1 Number of SIM Modules : 0 Number of Physical Drives : 28 Status : Normal Position : 1 Connector Name : Port B Enclosure type : SES VendorId is LSI CORP and Product Id is SAS2X36 VendorID and Product ID didnt match FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : 65 Inquiry data : Vendor Identification : LSI CORP Product Identification : SAS2X36 Product Revision Level : 0718 Vendor Specific : x36-55.7.24.1 Number of Voltage Sensors :2 Voltage Sensor :0 Voltage Sensor Status :OK Voltage Value :5020 milli volts Voltage Sensor :1 Voltage Sensor Status :OK Voltage Value :11820 milli volts Number of Power Supplies : 2 Power Supply : 0 Power Supply Status : OK Power Supply : 1 Power Supply Status : OK Number of Fans : 3 Fan : 0 Fan Speed :Low Speed Fan Status : OK Fan : 1 Fan Speed :Low Speed Fan Status : OK Fan : 2 Fan Speed :Low Speed Fan Status : OK Number of Temperature Sensors : 1 Temp Sensor : 0 Temperature : 48 Temperature Sensor Status : OK Number of Chassis : 1 Chassis : 0 Chassis Status : OK Enclosure 1: Device ID : 65 Number of Slots : 28 Number of Power Supplies : 2 Number of Fans : 3 Number of Temperature Sensors : 1 Number of Alarms : 1 Number of SIM Modules : 0 Number of Physical Drives : 28 Status : Normal Position : 1 Connector Name : Port A Enclosure type : SES VendorId is LSI CORP and Product Id is SAS2X36 VendorID and Product ID didnt match FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : 36 Inquiry data : Vendor Identification : LSI CORP Product Identification : SAS2X36 Product Revision Level : 0718 Vendor Specific : x36-55.7.24.1 Number of Voltage Sensors :2 Voltage Sensor :0 Voltage Sensor Status :OK Voltage Value :5020 milli volts Voltage Sensor :1 Voltage Sensor Status :OK Voltage Value :11760 milli volts Number of Power Supplies : 2 Power Supply : 0 Power Supply Status : OK Power Supply : 1 Power Supply Status : OK Number of Fans : 3 Fan : 0 Fan Speed :Low Speed Fan Status : OK Fan : 1 Fan Speed :Low Speed Fan Status : OK Fan : 2 Fan Speed :Low Speed Fan Status : OK Number of Temperature Sensors : 1 Temp Sensor : 0 Temperature : 47 Temperature Sensor Status : OK Number of Chassis : 1 Chassis : 0 Chassis Status : OK Enclosure 2: Device ID : 252 Number of Slots : 8 Number of Power Supplies : 0 Number of Fans : 0 Number of Temperature Sensors : 0 Number of Alarms : 0 Number of SIM Modules : 1 Number of Physical Drives : 0 Status : Normal Position : 1 Connector Name : Unavailable Enclosure type : SGPIO Failed in first Inquiry commnad FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : Unavailable Inquiry data : Vendor Identification : LSI Product Identification : SGPIO Product Revision Level : N/A Vendor Specific : Exit Code: 0x00 Now, notice that each slot 11 device shows an enclosure ID of 36, I think this is where the discrepancy happens. One should be 36. But the other should be on enclosure 65. Drives in slot 11: Enclosure Device ID: 36 Slot Number: 11 Drive's postion: DiskGroup: 5, Span: 0, Arm: 1 Enclosure position: 0 Device Id: 48 WWN: Sequence Number: 11 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SATA Raw Size: 2.728 TB [0x15d50a3b0 Sectors] Non Coerced Size: 2.728 TB [0x15d40a3b0 Sectors] Coerced Size: 2.728 TB [0x15d400000 Sectors] Firmware state: Online, Spun Up Is Commissioned Spare : YES Device Firmware Level: A5C0 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5003048000ee8a53 Connected Port Number: 1(path0) Inquiry Data: MJ1311YNG6YYXAHitachi HDS5C3030ALA630 MEAOA5C0 FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :30C (86.00 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Drive's write cache : Disabled Drive's NCQ setting : Enabled Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No Enclosure Device ID: 36 Slot Number: 11 Drive's postion: DiskGroup: 19, Span: 0, Arm: 1 Enclosure position: 0 Device Id: 19 WWN: Sequence Number: 4 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SATA Raw Size: 2.728 TB [0x15d50a3b0 Sectors] Non Coerced Size: 2.728 TB [0x15d40a3b0 Sectors] Coerced Size: 2.728 TB [0x15d400000 Sectors] Firmware state: Online, Spun Up Is Commissioned Spare : NO Device Firmware Level: A580 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5003048000ee8e53 Connected Port Number: 0(path0) Inquiry Data: MJ1313YNG1VA5CHitachi HDS5C3030ALA630 MEAOA580 FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :30C (86.00 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Drive's write cache : Disabled Drive's NCQ setting : Enabled Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No Update 06/28/12: I finally have some new information about (what we think) the root cause of this problem so I thought I would share. After getting in contact with a very knowledgeable Supermicro tech, they provided us with a tool called Xflash (doesn't appear to be readily available on their FTP). When we gathered some information using this utility, my colleague found something very strange: root@mogile2 test]# ./xflash.dat -i get avail Initializing Interface. Expander: SAS2X36 (SAS2x36) 1) SAS2X36 (SAS2x36) (50030480:00EE917F) (0.0.0.0) 2) SAS2X36 (SAS2x36) (50030480:00E9D67F) (0.0.0.0) 3) SAS2X36 (SAS2x36) (50030480:0112D97F) (0.0.0.0) This lists the connected enclosures. You see the 3 connected (we have since added a 3rd and a 4th which is not yet showing up) with their respective SAS address / WWN (50030480:00EE917F). Now we can use this address to get information on the individual enclosures: [root@mogile2 test]# ./xflash.dat -i 5003048000EE917F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:00EE917F Enclosure Logical Id: 50030480:0000007F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 [root@mogile2 test]# ./xflash.dat -i 5003048000E9D67F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:00E9D67F Enclosure Logical Id: 50030480:0000007F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 [root@mogile2 test]# ./xflash.dat -i 500304800112D97F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:0112D97F Enclosure Logical Id: 50030480:0112D97F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 Did you catch it? The first 2 enclosures logical ID is partially masked out where the 3rd one (which has a correct unique enclosure ID) is not. We pointed this out to Supermicro and were able to confirm that this address is supposed to be set during manufacturing and there was a problem with a certain batch of these enclosures where the logical ID was not set. We believe that the RAID controller is determining the ID based on the logical ID and since our first 2 enclosures have the same logical ID, they get the same enclosure ID. We also confirmed that 0000007F is the default which comes from LSI as an ID. The next pointer that helps confirm this could be a manufacturing problem with a run of JBODs is the fact that all 6 of the enclosures that have this problem begin with 00E. I believe that between 00E8 and 00EE Supermicro forgot to program the logical IDs correctly and neglected to recall or fix the problem post production. Fortunately for us, there is a tool to manage the WWN and logical ID of the devices from Supermicro: ftp://ftp.supermicro.com/utility/ExpanderXtools_Lite/. Our next step is to schedule a shutdown of these JBODs (after data migration) and reprogram the logical ID and see if it solves the problem. Update 06/28/12 #2: I just discovered this FAQ at Supermicro while Google searching for "lsi 0000007f": http://www.supermicro.com/support/faqs/faq.cfm?faq=11805. I still don't understand why, in the last several times we contacted Supermicro, they would have never directed us to this article :\

    Read the article

  • Android Dev Help: Saving an image from Res/raw or Asset folder to the Sd card

    - by Lucy
    Android Development Query Hello, I wonder if anyone could help me, i am trying to save an image (jpg or png) from the res/raw or assets folder to the SD card location (/sdcard/DCIM/). I have been following a tutorial which can save an image from a URL to the SD card Root, but i have looked everywhere to be able to save from res/raw or asset folder instead, and to a differnet location onthe sd card /sdcard/DCIM/ Here is the code, can anyone show me how to do the above from this? Thanks Lucy public class home extends Activity { private File file; private String imgNumber; private Button btnDownload; /** Called when the activity is first created. */ @Override public void onCreate(Bundle savedInstanceState) { super.onCreate(savedInstanceState); setContentView(R.layout.main); btnDownload=(Button)findViewById(R.id.btnDownload); btnDownload.setOnClickListener(new OnClickListener() { public void onClick(View v) { btnDownload.setText("Download is in Progress."); String savedFilePath=Download("http://www.domain.com/android1.png"); Toast.makeText(getApplicationContext(), "File is Saved in "+savedFilePath, 1000).show(); if(savedFilePath!=null) { btnDownload.setText("Download Completed."); } } }); } public String Download(String Url) { String filepath=null; try { //set the download URL, a url that points to a file on the internet //this is the file to be downloaded URL url = new URL(Url); //create the new connection HttpURLConnection urlConnection = (HttpURLConnection) url.openConnection(); //set up some things on the connection urlConnection.setRequestMethod("GET"); urlConnection.setDoOutput(true); //and connect! urlConnection.connect(); //set the path where we want to save the file //in this case, going to save it on the root directory of the //sd card. File SDCardRoot = Environment.getExternalStorageDirectory(); //create a new file, specifying the path, and the filename //which we want to save the file as. String filename= "download_"+System.currentTimeMillis()+".png"; // you can download to any type of file ex:.jpeg (image) ,.txt(text file),.mp3 (audio file) Log.i("Local filename:",""+filename); file = new File(SDCardRoot,filename); if(file.createNewFile()) { file.createNewFile(); } //this will be used to write the downloaded data into the file we created FileOutputStream fileOutput = new FileOutputStream(file); //this will be used in reading the data from the internet InputStream inputStream = urlConnection.getInputStream(); //this is the total size of the file int totalSize = urlConnection.getContentLength(); //variable to store total downloaded bytes int downloadedSize = 0; //create a buffer... byte[] buffer = new byte[1024]; int bufferLength = 0; //used to store a temporary size of the buffer //now, read through the input buffer and write the contents to the file while ( (bufferLength = inputStream.read(buffer)) > 0 ) { //add the data in the buffer to the file in the file output stream (the file on the sd card fileOutput.write(buffer, 0, bufferLength); //add up the size so we know how much is downloaded downloadedSize += bufferLength; //this is where you would do something to report the prgress, like this maybe Log.i("Progress:","downloadedSize:"+downloadedSize+"totalSize:"+ totalSize) ; btnDownload.setText("download Status:"+downloadedSize+" / "+totalSize); } //close the output stream when done fileOutput.close(); if(downloadedSize==totalSize) filepath=file.getPath(); //catch some possible errors... } catch (MalformedURLException e) { e.printStackTrace(); } catch (IOException e) { filepath=null; btnDownload.setText("Internet Connection Failed.\n"+e.getMessage()); e.printStackTrace(); } Log.i("filepath:"," "+filepath) ; return filepath; } }

    Read the article

  • Dell Poweredge R410 replace PERC S100 with PERC 6i

    - by Robe Eleckers
    I want to replace the PERC S100 RAID Controller with a PERC6i to be able to use 4 SAS harddrives instead of only SATA drives. What exactly do I need for this, what I've got so far: PERC6i PCIe x8 card. 4 x SAS 300GB 15000rpm drives Some questions I have Do I need a different backplane to accomodate the SAS disks? If so, what kind of backplane? Do I need a special cable to hookup the PERC6i with the backplane? If so, what kind of cable? Thanks.

    Read the article

  • RAIDZ vs RAID1+0

    - by Hiro2k
    Hi guys I just got 4 SSDs for my FreeNAS box. This server is only used to serve a single iSCSI extent to my Citrix XenServer pool and was wondering if I should setup them up in a RAIDZ or a RAID 1+0 configuration. This isn't used for anything in production, just for my test lab so I'm not sure which one is going to be better in this scenario. Will I see a major difference in speed or reliability? Currently the server has three 500GB Western Digital Blue drives and it's dog slow when I deploy a new version of our software on it, hence the upgrade.

    Read the article

  • HP Pavilion dv6000 graphics issue

    - by Tony
    A few days ago my laptop seized up on me while I was playing a game. When I restarted the computer, it sent me back to 640x480 resolution with 16 colors (clearly a graphical issue). In device manager, it shows an error, stating "Windows has stopped this device because it has reported problems. (Code 43)" regarding the video card. Upon removing and re-installing the drivers using both Windows Update and my own searching through nvidia's site, it's given me zero results. For kicks, I ran my antivirus (you never know!) and registry cleaner to see if anything would turn up. The antivirus found nothing, but CCleaner found 27 registry errors all dealing with my video card. What could be the cause of this, and what course of action would you recommend in this situation? Thanks in advance for the help! OS: Windows 7 Professional GPU: nvidia GeForce 8400M GS

    Read the article

  • How to know which block device maps to which physical drive

    - by Karolis T.
    I have a server with software RAID 1, two hot-swap sata disks. One hard drive started showing errors, I'm thinking about removing and replacing it, only problem is that I have no idea which of the two correspond to which devices. And I can't shut the server down to find out. I have /dev/sda and /dev/sdb, /dev/sda is the failing one. Thought about doing something along the lines # mdadm --manage /dev/md0 --remove /dev/sda1 then somehow stop/suspend the drive using tuning software and try to listen which of the two stopped, but that's not gonna work in a noisy server environment. Drive panels have no LEDs. Thanks for any ideas!

    Read the article

  • ZFS: Mirror vs. RAID-Z

    - by John Clayton
    I'm planning on building a file server using OpenSolaris and ZFS that will provide two primary services - be an iSCSI target for XenServer virtual machines & be a general home file server. The hardware I'm looking at includes 2x 4-port SATA controllers, 2x small boot drives (one on each controller), and 4x big drives for storage. This allows one free port per controller for upgrading the array down the road. Where I'm a little confused is how to setup the storage drives. For performance, mirroring appears to be king. I'm having a hard time seeing what the benefit would be of using RAIDZ over mirroring would be. With this setup I can see two options - two mirrored pools in one stripe, or RAIDZ2. Both should protect against 2 drive failures, and/or one controller failure...the only benefit of RAIDZ2 would be that any 2 drives could fail. The storage should be 50% of capacity in both cases, but the first should have much better performance, right? The other thing I'm trying to wrap my mind around is the benefit of mirrored arrays with more than two devices. For data integrity what, if any, would be the benefit of a RAIDZ over a three-way mirror? Since ZFS maintains file integrity what does RAIDZ bring to the table...doesn't ZFS's integrity checks negate the value of RAIDZ's parity?

    Read the article

  • Edirol UA-25 driver on Windows 8 Preview

    - by ETFairfax
    I've installed Windows 8 developer preview on a laptop and everything is working apart from my external sound card. The sound card in question is this one, and I've tried downloading and installing the Window 7 drivers from here but no joy so far. As per the instructions I remove the USB cable from the port. I then run setup.exe and (which I have set to run in Windows 7 compatibility mode). It starts doing it's stuff then says "Please insert the USB cable and wait"......that's where things stop! Nothing happens. I don't even here the "ding-dong" of the USB device being recoginised. Obviously I realise that the drivers are for windows 7 and not 8, but was hoping that someone would be able to crowbar it to work!!! Any tips appreciated. Thanks

    Read the article

  • High server load - [jbd2/md1-8] using 99.99% IO

    - by Alex
    I've been having spike in load over the last week. This usually occurs once or twice a day. I've managed to identify from iotop that [jbd2/md1-8] is using 99.99 % IO. During the high load times there is no high traffic to the server. Server specs are: AMD Opteron 8 core 16 GB RAM 2x2.000 GB 7.200 RPM HDD Software Raid 1 Cloudlinux + Cpanel Mysql is properly tuned Apart from the spikes, the load usually is around 0.80 at most. I've searched around but can't find what [jbd2/md1-8] does exactly. Has anyone had this problem or does anyone know a possible solution? Thank you. UPDATE: TIME TID PRIO USER DISK READ DISK WRITE SWAPIN IO COMMAND 16:05:36 399 be/3 root 0.00 B/s 38.76 K/s 0.00 % 99.99 % [jbd2/md1-8]

    Read the article

  • graphics cards with no HDMI output

    - by Noam Gal
    I am currently looking at Gainward GTX260 896MB GS GLH, but I've seen it also on the x275 version - the card doesn't have an HDMI output, only two dvi and one tv out (s-video?). They claim they support HDMI using a dvi-HDMI converter. Will I get a true high definition quality on my TV (assuming it supports it) like that? Or is it not as good, and I should stick to cards that have an HDMI output (ATI), or pay way too much for x295? What about connecting the audio? The x260 comes with an internal spdif cable - does that mean I can connect my soundcard to my graphics card, and have the audio come out through the dvi, and into the HDMI cable? Or am I mixing it all up here, and I have to somehow connect the sound to the TV using a seperate cable (Hoping it has a seperate audio-in for the HDMI channel)?

    Read the article

  • Getting around the lack of GPT support with CentOS 5.4

    - by sxanness
    Here is my issue and I hoping that there is someone out there that has an answer so I don't end up stuck here at my co-location all day. Last night I came here and upgraded a server (Dell 2970) to have four 1TB Hard Drives in RAID 5 which leaves a 3TB block. I tried to partition this but keep getting an error that GPT is not supported so I found a site online telling me I need to run the dd command and right random data to /dev/sda. This is great (if it works) but taking forever. I have two more machines to upgrade today and not a chair in site. Does anyone have advice on how I can avoid this issue beforehand? Thank You for your advice and support.

    Read the article

  • How to automatically disable secondary monitor in Windows 7

    - by Phenom
    My primary monitor is attached to my onboard video card. My secondary monitor is attached to my PCI-E card. When I first start my computer, only the primary monitor is on, and it is the only monitor that is recognized. While I'm in Windows 7, if I turn on my secondary monitor, Windows 7 automatically detects it, and expands my desktop to stretch across both monitors. But if I turn off the secondary monitor, Windows 7 doesn't automatically disable it. Is there a way I can get it to automatically disable when I turn it off, or is there a utility that makes it easier to disable it instead of having to go to screen resolution?

    Read the article

  • Streaming video from a point-and-shoot camera that doesn't support it

    - by egasimus
    I have a Canon IXUS 120is (PowerShot SD940) - a nice digital camera that's a couple of years old. It does record fairly decent video, but, alas, can't function as a webcam - and I need to stream video over the Web. I've installed CHDK on it, and while it's quite flexible, doesn't seem to provide a solution to my problem. I suppose that the video footage is written to the SD card in real time - is there a hack that allows me to monitor the file as it is written, and broadcast its contents over the Internet? Perhaps connecting its the camera's slot to my laptop's card reader via SDIO? I'm running Windows, but I'm roughly familiar with Linux; another question has suggested a file-to-/dev/video driver - do such tools exist?

    Read the article

  • Why use multiple partitions on a rhel server?

    - by Jakobud
    I'm about to reformat and reinstall CentOS onto an old server. The server runs on a modest 30 node small business network and has a variety of responsibilities including MySQL, a Samba share, DHCPd & SVN/Trac. The old sysadmin had this server setup with almost a dozen different partitions for various things. I'm trying to understand what the advantages of multiple partitions are as opposed to a just one filesystem at /. Speed? Flexibility? Security? It seems like if you misjudge the necessary size for any given partition and it ends up filling up too fast, it requires a sysadmin to go in and expand the partition, etc... Seems like it would be easier if everything was just one flat / filesystem. But I'm sure there are some advantages I'm not aware of. The server is currently running a handful of HDDs raided to ~2TB (raid 0).

    Read the article

  • kernel: journal commit I/O error

    - by jasondewitt
    I am having some problems with a Dell 1950 server. I am installing RHEL 4.6 along with Oracle and some other software on here. I am randomly getting an error message saying "kernel: journal commit I/O error" on my ssh session and on the monitor I have hooked up to the server I see an error scrolling by that says "EXT3-fs error (device sda5) in start_transaction: Journal has aborted." It has happened several times but never at the same point during the install. Actually, this last time the system was up and running and I was just trying to import a database into oracle. This has happened on several hard drives, so I'm pretty sure that is not the problem. This makes me think the raid controller is going bad. What do you guys think? ** UPDATE ** Pretty sure it was a bad hard drive. I threw another drive in the server and it's been running for about 48 hours with out problems.

    Read the article

  • X-FI optical output not being recognized.

    - by Luciano
    Hello there! I have an issue and I don't know what to do! I have a SoundBlaster X-FI Xtreme Gamer, which has a spdif mini-optical output. I have it connected to a home theater, via a toslink cable and an adapter to fit in the mini plug. It used to work perfectly, but now it doesn't anymore. There is light travelling through the cable, but the HT doesn't pick up the signal. The sound card of the motherboard also has an optical output (regular, not mini) and it works ok, so the cable and the HT are fine, I think. What else should I try? Thanks, Luciano. PS: I only enabled the onboard card for testing, but usually it's disabled to avoid any kind of conflicts. PPS: I'm using Windows 7 64bit with latest drivers of everything, but like I said. It used to work.

    Read the article

  • Virtual Machines: What components should I upgrade to improve running virtual machines?

    - by joshsvoss
    at work I need to have one or sometimes two instances of a vmware virtual Windows 7 machine running on my real Windows 7 machine. The computer I'm using is Dell Precision 490 from 2009 I believe, possibly earlier. Running Windows 7 ultimate. Problems while running VM's: The entire computer slows down when a vmware instance is running. Pages take a while to react to a scroll, applications take forever to launch, and programs hang both in the virtual machines and on the real one. So, what components should I upgrade to improve this? I guess a more pointed question would be, which components will help the most? Possible options: Getting 8gb of RAM instead of 4gb new graphics card new processors? (Is that really an option?) My intuition tells me it will be a combination of the RAM and graphics card. There is also the possibility that an '09 tower just isn't cut out for vm's and our business should purchase a new tower.

    Read the article

  • Upgrading NAS hard drives

    - by Mihai Damian
    I was thinking of buying a NAS for home-usage. I've never used a NAS or had HDDs set up in Raids. Before I commit myself to moving all my data to a NAS I need to find out how difficult it is to upgrade and replace the NAS' hard drives. Suppose I set up a Raid 1 NAS with two 1TB hdds. At some point in the future I will use up all the space and will have to install two new 2TB hdds. Now I'll need to migrate the data from the old disks to the new ones. Will I have to hook up one of the old disks in a computer and copy all the data back in the NAS? Or can the migration be done using only the NAS? I realize the answer to the question might depend on the NAS model. Being a simple for-home solution I was thinking of getting something along the lines of D-link's 323.

    Read the article

  • Can't Use Switchable Graphics

    - by Rev
    I can't get my switchable graphics cards working on my Acer 4820TG laptop. It came installed with Windows 7, but I've installed the RTM build of Windows 8. I have to keep the "Graphics" setting on the BIOS set to "Discrete," if it's set to "Switchable" the screen turns black after the boot animation is complete. The machine has an Intel graphics card and an AMD Mobility Radeon HD 5650, and I know that the Intel card is working. I've seen it work a couple of times with Windows 8 installed, but for some reason it just doesn't anymore. I know that it's not broken, because when I plug in a secondary monitor, and move the cursor to the right, I can see it on that monitor. Are there drivers or something I need to install? I've tried a number of drivers and utilities from Acer's website, none of which have fixed the problem.

    Read the article

  • How to detect hard disk failure?

    - by Devator
    So, one of my servers has a hard disk failure. It's running software RAID, the system locked up and according to /proc/mdstat (and /var/log/messages), it's really down: Personalities : [raid1] md2 : active raid1 sdb2[1] 104320 blocks [2/1] [_U] md5 : active raid1 sdb5[1] 2104448 blocks [2/1] [_U] md6 : active raid1 sdb6[1] 830134656 blocks [2/1] [_U] md1 : active raid1 sdb1[1] 143363968 blocks [2/1] [_U] and Nov 5 22:04:37 m38501 smartd[4467]: Device: /dev/sda, not capable of SMART self-check However when I do smartctl -H /dev/sda, it passes the test. It also passes the test with smartctl --test=short /dev/sda. So, is smartctl a broken testing tool, or am I doing something completely off?

    Read the article

  • Adding a single 300Gb SCSI drive to poweredge 2850

    - by John Steele
    I have a 2850 setup with 3 146Gb drives, two partitions 1 12GB system with server 2003 sp2 and 1 261Gb Data. I am strapped on disk space on the data partition having to push data around. I wanted to add a 300Gb single drive for lesser critical data, is this possible? Or is it best to add 2 300Gb drives for another RAID 1 configuration? This is my church network and while it is mission critical it is not enterprise so I can take it down for a few hours. Any pointers to documentation or direct help would be greatly appreciated. John

    Read the article

  • best storage option for recording live streaming video

    - by Alchemical
    We're creating a new web site that includes video chat capabilities. Wowza Server is being used for the streaming media. We would like the capability for users to record their video chats in certain circumstances. Is it feasible to record the videos to the same server running Wowza? Or performance-wise, would it make more sense to store them on another server? I understand SANs are popular as well, but I'm a little concerned about cost for those as we are on a fairly tight budget. Currently we have two servers with pretty decent RAID cnofigurations for storage, one has 14TB and the other 6TB. Mostly concerned if doing the recording on the same server as the streaming server (or web server), could significantly adversely affect that server's primary function.

    Read the article

  • Using 2-port LSI 2308-8e card to control 24 SAS HDDs

    - by GregC
    I would like to rely on a RAID-on-chip solution to control 24 SAS hard drives in a direct-attached environment. How would you approach this to get best bandwidth given that I'd like to spend less than $10,000 on the interconnect. I've read that LSI 2308 chip can easily handle 8-drive SSD RAID6 in hardware. I'd like to harness its power to control 24 SAS hard drives over an expander in an external enclosure. Currently I use an Infortrend S24S-G2240 external enclosure. It provides its own controller and expander. I'd like to use LSI 2308 controller for RAID6 somehow instead of the mystery controller in the enclosure. P.S. I tried to create SAS-expander as a tag, but my rep on this site is low.