  • HP ProCurve GVRP Setup

    - by Matt
    I'm trying to setup GVRP on my 4 ProCurve switches. Currently I have a Layer 3 3500yl-24G (J8692A) which is connected to 3 Layer 2 2510G-48 (J9280A). I have three trunk ports setup on the 3500 connected to the 3 switches and currently everything seems to be working, the devices are talking to eachother and GVRP is pushing its configurations from the 3500 to the 3 other switches. My question is, once GVRP is setup, how exactly do I configure the ports on the 3 L2 switches to use the correct VLAN? I'm new to ProCurve network equipment and this is much easier to setup on Cisco equipment.

    Read the article

  • Configuring VLAN's on two HP procurve switches

    - by pan
    Trying to route a new ISP (Microwave link) from one of my out buildings to my computer room and hence my firewall. Old ISP came direct into firewall. In the outbuilding the Microwave modem connects with cat5 to HP Procurve 2524 switch. Because this ISP is coming through my internal network, I plan on using a new vlan called "airspeed" only for this ISP traffic. Up until now I've just been using the Default_vlan on both HP switches (4108 + 2524). So far I've been unable to ping from my laptop to the ISP modem both of which are on the new vlan 2 ("Airspeed"). No traffic needs to cross from vlan 2 to vlan 1 so I've left the ports as untagged. I've used the subnet provide from my ISP as the new vlan 2 subnet. Can anybody see what I'm doing wrong here? I've added the configuration of both switch below. Rough diagram: Microwave modem (Gateway IP 77.75.00.49) | HP 2524 switch (port 24) | HP 2524 switch fibre link | HP 4108GL switch fibre link | HP 4108GL switch (port D1) | Laptop configured with IP 77.75.00.50 (for testing but will be connected to firewall) And my 4108GL config: ; J4865A Configuration Editor; Created on release #G.07.21 hostname "HP ProCurve Switch 4108GL" cdp run module 1 type J4864A module 2 type J4862B module 3 type J4862B module 4 type J4862B ip default-gateway 128.1.146.50 snmp-server community "public" Unrestricted snmp-server host 128.1.146.51 "public" Not-INFO snmp-server host 128.1.146.38 "public" vlan 1 name "DEFAULT_VLAN" untagged A1-A3,B1-B24,C1-C24,D2-D24 ip address 128.1.146.203 255.255.0.0 no untagged D1 exit vlan 2 name "Airspeed" untagged D1 ip address 77.75.00.51 255.255.255.248 exit Finally my 2524 config: ; J4813A Configuration Editor; Created on release #F.04.08 hostname "HP ProCurve Switch 2524" cdp run ip default-gateway 0.0.0.0 snmp-server community "public" Unrestricted snmp-server host 128.1.146.51 "public" Not-INFO snmp-server host 128.1.146.51 "public" snmp-server host 128.1.146.38 "public" vlan 1 name "DEFAULT_VLAN" untagged 1-23,25-26 no untagged 24 ip address 128.1.146.204 255.255.0.0 exit vlan 2 name "Airspeed" untagged 24 ip address 77.75.00.51 255.255.255.248 exit no aaa port-access authenticator active

    Read the article

  • Setup VLAN agnostic ports on HP ProCurve 1810G (Ingress Filter, Trunking)

    - by Thomas
    I am wondering if it is possible to configure some ports of the web managed ProCurve Switch 1810G to participate in all VLAN traffic. Even if no VLAN with that ID has been set up inside the switch. The issue is that I have two virtualization servers that will use yet unknown VLANs of a certain range to communicate with each other. But the range is much larger than the 64 supported VLANs this switch can manage. The switch also offers static and LACP Link Trunks. But I guess there will also apply the Ingress Filter that drops packets with unconfigured VLAN IDs? A separate unmanaged switch that connects the two hosts and one ProCurve Port would work, but maybe I do not have to? Thanks

    Read the article

  • ProCurve 1800 switch issue

    - by user98651
    I recently deployed ProCurve 1800-24G switches in place of some older ProCurve 2424M switches in my network. However, I'm having a serious problem with the switch connected to the router. It seems, every night when our Windows 2008 R2 server (off site) runs a backup to a iSCSI target (on site) [facilitated through a PPTP tunnel] the LAN loses connectivity with the router. To clarify, there is only one router which is connected to the switch affected by this problem. The only way to resolve the issue is to either reboot the router or pull the ethernet cable that goes to the router and plug it back in. During the outage, clients cannot receive DHCP requests, DNS requests, ping, or do anything else with the router in this state. Now, neither the switch or router are configured extensively and the issue only seems to have surfaced with the new switch in place. I have tried a number of things including replacing cables, rebooting and checking the switch configuration (it is literally as basic as you can get at this point-- flat LAN, no trunking). Interestingly, the router shows (accessed externally) no changes in configuration or status during this state but similarly cannot ping or access other hosts on the network. This issue occurs in different stages of backup (ie, different amounts transferred). I've also dumped packets from the switch into WireShark but cannot seem to find any anomaly yet (I'm looking at packets around the time the issue appeared and at the time when I reset the NIC). Any suggestions for what to look for? Ideas on what could be causing this? I'm seeing some transmit/receive errors on the NIC from both the router and switch side but nothing serious when compared to the total packet counts. I'm seriously doubting hardware at this point, as I have tried another switch, different cables, and a different NIC on the router.

    Read the article

  • ProCurve ACL to prevent a subnet from leaving the switch

    - by kce
    I have a single HP ProCurve 2610 in a remote location that is connected in with the rest of the network via SHDSL. There are two Layer-3 networks on this segment. ACLs are setup to deny one subnet (192.0.2.0/24) from ever being able to leave the switch by virtue of being applied to port attached to the upstream connection. The other subnet should be permitted to freely leave the switch. Both subnets are on the same VLAN. Unfortunately SFlow very clearly show broadcast traffic from 192.0.2.0/24 on the upstream connection. ProCurve ACLs are not my strong suit but I feel like I'm missing something very simple here. ip access-list extended "Filter for Camera Network" deny ip 192.0.2.0 0.0.0.255 0.0.0.0 255.255.255.255 log permit ip 0.0.0.0 255.255.255.255 0.0.0.0 255.255.255.255 exit interface 24 name "DSL - UPLINK" access-group "Filter for Camera Network" in exit Unless I am mistaken traffic from 192.0.2.0/24 should be dropped as it crosses the uplink port (int 24) whereas all other traffic will be permited by the following default allow rule. What exactly am I missing here? EDIT: Firstly, why do you have two subnets contained in the same VLAN? Because that's how it was configured by a previous administrator and while it makes conceptual sense that a single subnet is "mapped" to a single VLAN there's no technical constraint that I am aware of that makes this have to be the case. Instead of filtering inbound traffic on your uplink, you should be filtering outbound traffic. The HP2600 series can only filter inbound traffic on interfaces. Should I change my filter to deny any to 192.0.2.0/24?

    Read the article

  • Multiple vlan issue with procurve switch

    - by Chris-AZ
    I have a cisco asa5505 as my rtr/fw(10.1.3.254). I have vlan 1 and vlan 3. Vlan 1 is my default all access vlan. Vlan 3 is my Guest(dmz) vlan. I can't seem to get a dhcp ip address when my laptop is plugged into port 42 on my procurve. I have plugged my laptop directly into the firewall and it gets a dhcp ip fine(the firewall is dhcp server). the firewall is plugged into port 41. Only vlan3 needs to go over port 41. I'm sure I have a bonehead config problem however I'm about ready to pull out what little hair I have left. vlan 1 name "Computers" forbid 45 untagged 1-41,43-44 ip helper-address 10.1.1.16 ip address 10.1.1.1 255.255.255.0 tagged 46-48 no untagged 42,45 exit vlan 3 name "Guest Wireless" ip helper-address 10.1.3.254 ip address 10.1.3.1 255.255.255.0 tagged 41-42,44-48 exit

    Read the article

  • 2 HP Procurve 4000M switches and Comcast SMC Gateway

    - by Cole Tierney
    We've got 2 HP Procurve 4000M switches joined by a trunk. Switch 1 is connected to a Cisco 2600 router which is connected to a T1. Internet traffic for hosts on switch 2 must pass through the trunk to switch 1. We're now switching to Comcast who's given us 4 port SMC router. I would like to connect each switch to the comcast router to reduce traffic on the trunk, but I don't want to create a loop. The switches support spanning tree protocol, but I don't know how this would work with the comcast router. Would a triangle network like this work? Thanks for any tips.

    Read the article

  • Admin mode on Procurve Switches

    - by stefan.at.wpf
    Not being a network expert, I spent some time configuring my network, until I found my mistake: On my HP ProCurve Switch 1810G, I thought that "Admin mode" means whether the administrative interface can be accessed from this port. Well, it means whether the port is enabled or not. Extract from the help function: Admin Mode - Select to enable the port-control administration state. Click to enable and have the port participate in the network.(Default : Enabled ) Well, of course I didn't read the help, because I didn't doubt it's for the adminsitrative interface and suspected an error somewhere else. Anyway, I am wondering if that is a commonly used term for enabling/disabling ports or if HP just wanted to make my life harder? I can't understand why this option isn't just called "Enable port"!? Here's a screenshot of how it looks in the web interface (yeah, shame on me for using a web interface)

    Read the article

  • Hp Procurve Switch : port filtered

    - by user117140
    My HP Procurve switch is blocking port 22 and I dont know how to unblock it.Please let me know From the server, see port 22 is blocked [root@server ~]#nmap -p22,80,443 10.247.172.70 Starting Nmap 4.11 ( http://www.insecure.org/nmap/ ) at 2012-04-16 14:12 IST mass_dns: warning: Unable to determine any DNS servers. Reverse DNS is disabled. Try using --system-dns or specify valid servers with --dns_servers Interesting ports on 10.247.172.70: PORT STATE SERVICE 22/tcp filtered ssh ------------------> see 80/tcp filtered http 443/tcp filtered https This is blocked on cisco switch but I dont have any clue how this is done. I know that vlan is configured on switch. vlan 54 ip ospf 10.247.172.65 area 0.0.0.10 vrrp vrid 54 owner virtual-ip-address 10.247.172.65 255.255.255.192 priority 255 enable exit exit Please let me know how to unblock ssh port 22 access on this switch?

    Read the article

  • HP ProCurve & Cisco switches interoperability

    - by Kamil Z
    I have a couple of questions regarding Cisco and HP ProCurve interoperability. Here's a link to pdf with my network topology. Can someone help me with basic VLAN configuration in such topology? Below there are some details of my configuration: # m_management_2 interface FastEthernet0/43 switchport access vlan 250 switchport mode access spanning-tree port-priority 32 spanning-tree cost 100 # MTA2-swmgmt1 vlan 1 name "DEFAULT_VLAN" untagged 1-48 ip address 10.10.249.190 255.255.255.128 exit # MTA2-swtr1 vlan 1 name "DEFAULT_VLAN" untagged 1-14,16-48 no ip address no untagged 15 exit vlan 100 name "MTA Mgmt" untagged 15 ip address 10.10.249.188 255.255.255.128 exit # MTA2-swtr2 vlan 1 name "DEFAULT_VLAN" untagged 1-14,16-48 no ip address no untagged 15 exit vlan 100 name "MTA Mgmt" untagged 15 ip address 10.10.249.189 255.255.255.128 exit I don't post MTA2-bcsw[12] configuration, because I wasn's successfull in this one yet. Every time I configure VLANs on MTA2-bcsw[12] Fa0/24 interface on m_management_2 goes down bacause of receiving tagged BPDUs on access port (there are no VLANs configured on MTA2-swmgmt1 because of fact that only 250 VLAN is allowed in this switch. Is it correct?). Can someone provide me some basic configuration for this topology? Second thing I want to ask is concept of connection from MTA2-swmgmt1 to MTA2-swtr[12] HP switches for the sake of management. How to configure such ports on HP switches (managed switch and manager switch). Is my actual configuration correct?

    Read the article

  • Setup of HP ProCurve 2810-24G for iSCSI?

    - by 3molo
    Hi, I have a pair of ProCurve 2810-24G that I will use with a Dell Equallogic SAN and Vmware ESXi. Since ESXi does MPIO, I am a little uncertain on the configuration for links between the switches. Is a trunk the right way to go between the switches? I know that the ports for the SAN and the ESXi hosts should be untagged, so does that mean that I want tagged VLAN on the trunk ports? This is more or less the configuration: trunk 1-4 Trk1 Trunk snmp-server community "public" Unrestricted vlan 1 name "DEFAULT_VLAN" untagged 24,Trk1 ip address 10.180.3.1 255.255.255.0 no untagged 5-23 exit vlan 801 name "Storage" untagged 5-23 tagged Trk1 jumbo exit no fault-finder broadcast-storm stack commander "sanstack" spanning-tree spanning-tree Trk1 priority 4 spanning-tree force-version RSTP-operation The Equallogic PS4000 SAN has two controllers, with two network interfaces each. Dell recommends each controller to be connected to each of the switches. From vmware documentation, it seems creating one vmkernel per pNIC is recommended. With MPIO, this could allow for more than 1 Gbps throughput.

    Read the article

  • ProCurve network expansion

    - by Blue Warrior NFB
    I've hit a bit of a wall with our network scale-out. As it stands right now: We have five ProCurve 2910al switches connected as above, but with 10GbE connections (two CX4, two fiber). This fully populates the central switch above, there will be no more 10GbE Ethernet connections from that device. This group of switches is not stacked (no stack directive). Sometime in the next two or three months I'll need to add a sixth, and I'm not sure how deep of a hole I'm in. Ideally I'd replace the core switch with something more capable and has more 10GbE ports. However, that's a major outage and that requires special scheduling. The two edge switches connected via fiber have dual-port 10GbE cards in them, so I could physically put another switch on the far end of one of those. I don't know how much of a good or bad idea that would be though. Is that too many segments between end-points? Some config-excerpts: Running configuration: ; J9147A Configuration Editor; Created on release #W.14.49 hostname "REDACTED-SW01" time timezone 120 module 1 type J9147A module 2 type J9008A module 3 type J9149A no stack trunk B1 Trk3 Trunk trunk B2 Trk4 Trunk trunk A1 Trk11 Trunk trunk A2 Trk12 Trunk vlan 15 name "VM-MGMT" untagged Trk2,Trk5,Trk7 ip helper-address 10.1.10.4 ip address 10.1.11.1 255.255.255.0 tagged 37-40,Trk3-Trk4,Trk11-Trk12 jumbo ip proxy-arp exit

    Read the article

  • 10 GigE interfaces limits single connection throughput to 1 Gb on a ProCurve 4208vl

    - by wazoox
    The setup is as follow : 3 Linux servers with Intel CX4 10 GigE controllers and an X-Serve with a Myricom 10 GigE CX4 controller are connected to a ProCurve 4208vl switch, with a myriad of other machines connected through good ol' 1000 base-T. The interfaces are actually set up as 10 Gig, according to both the switch monitoring interface and the servers (ethtool, etc). However a single connection between two 10 GigE equipped machines through the switch is limited to exactly 1Gb. If I connect two of the 10 GigE machines directly with a CX4 cable, netperf reports the link bandwidth as 9000 Mb/s. NFS achieves about 550 MB/s transfers. But when I'm using the switch, the connection tops at 950 Mb/s through netperf and 110 MB/s with NFS. When I open several connections from 3 of the machines to the 4th, I get 350 MB/s of NFS transfer speed. So each individual 10 GigE ports actually can reach much more than 1 Gb, but individual connections are strictly limited to 1 Gb. Conclusion : the 10 GigE connection through the switch behaves exactly like a trunk of 10 1 Gb connections. That doesn't make any sense to me, unless HP planned these ports only for cascading switches or strictly for many-clients-to-single-server connection. Unfortunately this is NOT the envisioned setup, we need big throughput from machine to machine. Is this a not-so-known (or carefully hidden...) limitation of this type of switch? Should I suggest seppuku to the HP representative? Does anyone have any idea on how to enable a proper behaviour ? I upgraded for an hefty price from bonded 1Gb links to 10 GigE and see exactly ZERO gain! That's absolutely unacceptable.

    Read the article

  • Procurve Primary VLAN

    - by fukawi2
    I'm trying to depreciate usage of VLAN 1 on my ProCurve switches; 1 is unused. I understand that VLAN 1 must exist, but I want to remove it from all ports, especially trunks between switches. The problem I have is that stacking does not seem to work without VLAN 1. I have changed the primary VLAN and management VLAN on all the switches: (config)# primary-vlan 42 (config)# management-vlan 42 (config)# no vlan 1 untagged 25 Port 25 is the link between the 2 switches I'm testing with; the stack master and a member switch; I only want tagged traffic between the switches, no untagged frames. show stacking on the master shows all members as "UP" but I can not telnet any of them: Telnet failed: Connection timed out. All switches have manually assigned (static) IP addresses on VLAN 42, and all exist in the same /25 subnet, as does my desktop. I can telnet the switches directly from my desktop to the individual switch IP addresses, just not from the master switch. Do I need to reboot the switches to have the primary-vlan change take effect? Or is there something else I'm missing?

    Read the article

  • dhcp-snooping option 82 drops valid dhcp requests on 2610 series Procurve switches

    - by kce
    We are slowly starting to implement dhcp-snooping on our HP ProCurve 2610 series switches, all running the R.11.72 firmware. I'm seeing some strange behavior where dhcp-request or dhcp-renew packets are dropped when originating from "downstream" switches due "untrusted relay information from client". The full error: Received untrusted relay information from client <mac-address> on port <port-number> In more detail we have a 48 port HP2610 (Switch A) and a 24 port HP2610 (Switch B). Switch B is "downstream" of Switch A by virtue of a DSL connection to one of Switch A ports. The dhcp server is connected to Switch A. The relevant bits are as follows: Switch A dhcp-snooping dhcp-snooping authorized-server 192.168.0.254 dhcp-snooping vlan 1 168 interface 25 name "Server" dhcp-snooping trust exit Switch B dhcp-snooping dhcp-snooping authorized-server 192.168.0.254 dhcp-snooping vlan 1 interface Trk1 dhcp-snooping trust exit The switches are set to trust BOTH the port the authorized dhcp server is attached to and its IP address. This is all well and good for the clients attached to Switch A, but the clients attached to Switch B get denied due to the "untrusted relay information" error. This is odd for a few reasons 1) dhcp-relay is not configured on either switch, 2) the Layer-3 network here is flat, same subnet. DHCP packets should not have a modified option 82 attribute. dhcp-relay does appear to be enabled by default however: SWITCH A# show dhcp-relay DHCP Relay Agent : Enabled Option 82 : Disabled Response validation : Disabled Option 82 handle policy : append Remote ID : mac Client Requests Server Responses Valid Dropped Valid Dropped ---------- ---------- ---------- ---------- 0 0 0 0 SWITCH B# show dhcp-relay DHCP Relay Agent : Enabled Option 82 : Disabled Response validation : Disabled Option 82 handle policy : append Remote ID : mac Client Requests Server Responses Valid Dropped Valid Dropped ---------- ---------- ---------- ---------- 40156 0 0 0 And interestingly enough the dhcp-relay agent seems very busy on Switch B, but why? As far as I can tell there is no reason why dhcp requests need a relay with this topology. And furthermore I can't tell why the upstream switch is dropping legitimate dhcp requests for untrusted relay information when the relay agent in question (on Switch B) isn't modifying the option 82 attributes anyway. Adding the no dhcp-snooping option 82 on Switch A allows the dhcp traffic from Switch B to be approved by Switch A, by virtue of just turning off that feature. What are the repercussions of not validating option 82 modified dhcp traffic? If I disable option 82 on all my "upstream" switches - will they pass dhcp traffic from any downstream switch regardless of that traffic's legitimacy? This behavior is client operating system agnostic. I see it with both Windows and Linux clients. Our DHCP servers are either Windows Server 2003 or Windows Server 2008 R2 machines. I see this behavior regardless of the DHCP servers' operating system. Can anyone shed some light on what's happening here and give me some recommendations on how I should proceed with configuring the option 82 setting? I feel like i just haven't completely grokked dhcp-relaying and option 82 attributes.

    Read the article

  • LACP : Cisco ASA 5515 & Switch ProCurve 2920

    - by user979276
    I've two ASAs 5515 connected in failover Active/Stand by (on Gi0/5) My two ASAs are connected to two Switch ProCurve 2920 to have HA if something happens. So I plug something like that (don't pay attention to the arrows) : So one the ASA, I created a Port-Channel like that : interface GigabitEthernet0/0 nameif outside security-level 0 ip address 192.168.1.3 255.255.255.0 standby 192.168.1.4 ! interface GigabitEthernet0/1 speed 1000 duplex full channel-group 1 mode passive no nameif no security-level no ip address ! interface GigabitEthernet0/2 speed 1000 duplex full channel-group 1 mode passive no nameif no security-level no ip address ! interface Port-channel1.1 vlan 1 nameif inside security-level 100 ip address 192.168.8.1 255.255.255.0 standby 192.168.8.2 ! interface Port-channel1.10 vlan 10 nameif guest security-level 50 ip address 172.16.100.2 255.255.255.224 standby 172.16.100.3 ! interface Port-channel1.16 vlan 16 nameif dmz security-level 50 ip address 192.168.16.1 255.255.255.0 standby 192.168.16.2 On the switch, I created a trunk LACP capable with the port 1 and 2 on each switch, force the speed to 1000 and put the port un full duplex mode. BUT this is not working... I tried many things and I can't make it work. In this configuration, I can't ping anything between my ASA and my Switch (or any object connected). Here what I get on my ASA : Channel group 1 LACP port Admin Oper Port Port Port Flags State Priority Key Key Number State ----------------------------------------------------------------------------- Gi0/2 SP not-bndl 32768 0x1 0x1 0x3 0xc Gi0/1 FP not-bndl 32768 0x1 0x1 0x2 0x6 And on the Switchs : PORT LACP TRUNK PORT LACP LACP NUMB ENABLED GROUP STATUS PARTNER STATUS ----- ------- ----- ------ ------- ------ 1 Active trk1 Broken Yes Failure 2 Active trk1 Broken Yes Failure If I change the Cisco interface to LACP mode On, I can ping the switch from the ASA but nothing other objects conneted on the switch. If I look at the statut of LACP on the switch I see this : PORT LACP TRUNK PORT LACP LACP NUMB ENABLED GROUP STATUS PARTNER STATUS ----- ------- ----- ------ ------- ------ 1 Active trk1 Up No Success 2 Active trk1 Up No Success I don't have any clue on what's going on so If someone have any idea and help me on this, it would be great ! Feel free to ask me anything if you need any more information ! Thanks a lot !

    Read the article

  • Load-balancing between a Procurve switch and a server

    - by vlad
    Hello I've been searching around the web for this problem i've been having. It's similar in a way to this question: How exactly & specifically does layer 3 LACP destination address hashing work? My setup is as follows: I have a central switch, a Procurve 2510G-24, image version Y.11.16. It's the center of a star topology, there are four switches connected to it via a single gigabit link. Those switches service the users. On the central switch, I have a server with two gigabit interfaces that I want to bond together in order to achieve higher throughput, and two other servers that have single gigabit connections to the switch. The topology looks as follows: sw1 sw2 sw3 sw4 | | | | --------------------- | sw0 | --------------------- || | | srv1 srv2 srv3 The servers were running FreeBSD 8.1. On srv1 I set up a lagg interface using the lacp protocol, and on the switch I set up a trunk for the two ports using lacp as well. The switch showed that the server was a lacp partner, I could ping the server from another computer, and the server could ping other computers. If I unplugged one of the cables, the connection would keep working, so everything looked fine. Until I tested throughput. There was only one link used between srv1 and sw0. All testing was conducted with iperf, and load distribution was checked with systat -ifstat. I was looking to test the load balancing for both receive and send operations, as I want this server to be a file server. There were therefore two scenarios: iperf -s on srv1 and iperf -c on the other servers iperf -s on the other servers and iperf -c on srv1 connected to all the other servers. Every time only one link was used. If one cable was unplugged, the connections would keep going. However, once the cable was plugged back in, the load was not distributed. Each and every server is able to fill the gigabit link. In one-to-one test scenarios, iperf was reporting around 940Mbps. The CPU usage was around 20%, which means that the servers could withstand a doubling of the throughput. srv1 is a dell poweredge sc1425 with onboard intel 82541GI nics (em driver on freebsd). After troubleshooting a previous problem with vlan tagging on top of a lagg interface, it turned out that the em could not support this. So I figured that maybe something else is wrong with the em drivers and / or lagg stack, so I started up backtrack 4r2 on this same server. So srv1 now uses linux kernel 2.6.35.8. I set up a bonding interface bond0. The kernel module was loaded with option mode=4 in order to get lacp. The switch was happy with the link, I could ping to and from the server. I could even put vlans on top of the bonding interface. However, only half the problem was solved: if I used srv1 as a client to the other servers, iperf was reporting around 940Mbps for each connection, and bwm-ng showed, of course, a nice distribution of the load between the two nics; if I run the iperf server on srv1 and tried to connect with the other servers, there was no load balancing. I thought that maybe I was out of luck and the hashes for the two mac addresses of the clients were the same, so I brought in two new servers and tested with the four of them at the same time, and still nothing changed. I tried disabling and reenabling one of the links, and all that happened was the traffic switched from one link to the other and back to the first again. I also tried setting the trunk to "plain trunk mode" on the switch, and experimented with other bonding modes (roundrobin, xor, alb, tlb) but I never saw any traffic distribution. One interesting thing, though: one of the four switches is a Cisco 2950, image version 12.1(22)EA7. It has 48 10/100 ports and 2 gigabit uplinks. I have a server (call it srv4) with a 4 channel trunk connected to it (4x100), FreeBSD 8.0 release. The switch is connected to sw0 via gigabit. If I set up an iperf server on one of the servers connected to sw0 and a client on srv4, ALL 4 links are used, and iperf reports around 330Mbps. systat -ifstat shows all four interfaces are used. The cisco port-channel uses src-mac to balance the load. The HP should use both the source and destination according to the manual, so it should work as well. Could this mean there is some bug in the HP firmware? Am I doing something wrong?

    Read the article

  • HP Procurve Issue Passing Multiple VLANs over a link

    - by MichaelRwat
    Just to start off with I am a Cisco guy that got placed into an HP project. Basic topology overview from outside in: ASA 5505 with two Ethernet connections to a 2910-24 port switch. This switch is then (Cisco Trunking) to a 2626 switch passing vlan (1 untagged and 100 tagged)between them. I created SVI's on each of the switches for both VLAN's for testing purposes. I can not get vlan 100 to pass across this link. I also have trunks configured to AP's off of the switch and can not ping the vlan 100 BVI on the AP's but can reach the vlan 1 BVI. Port 25 on Access layer (2626) connects (trunks) with port A1 of 2610. STP is not running at all on any switch (this is not my network I can't change this nor did I design this) Distribution Sw: MP1-0# show run ip default-gateway 10.100.100.100 vlan 1 name "DATA" untagged 1-22,24-A1,B1 ip address 10.100.100.6 255.255.255.0 no untagged 23 exit vlan 100 name "GUEST" untagged 23 tagged 24-A1 ip address 10.100.102.6 255.255.255.0 exit Access Sw: ip default-gateway 10.100.100.100 vlan 1 name "DEFAULT_VLAN" untagged 1-26 ip address 10.100.100.5 255.255.255.0 exit vlan 100 name "GUEST" ip address 10.100.102.5 255.255.255.0 tagged 15,25 exitt From the ASA I can ping the vlan 100 address of the 2610 but not the 2626 (10.100.102.6)[Not passing the "trunk"] If I plug into an access port vlan 100 of the 2626 I can ping the SVI for vlan 100 as intended. I can not ping across the "trunk" over vlan 100 but I can across vlan 1. There may be something obvious I'm missing but please review my configuration and thank you for the assistance.

    Read the article

  • How to prevent partial crash during VLAN configuration on a HP ProCurve 3500

    - by vm370
    as you can see from my question, I have a VLAN configuration problem with a ProCurve3500. The goal is to remove a VLAN from the existing configuration, however when I use the WEB UI to do this, I cannot modify ports to be assigned to a different VLAN or the Default VLAN. I always get the message "config failed", which is not very helpful. When I try to do it over telnet, the router somehow partially crashes and somehow the utilization on all ports is at 100% and I can barely use the web ui. After a reboot everything is fine again, but the configuration was not changed... The traffic after this partial crash looks like a broadcast storm, however there are definitely no loops in the segment. I also updated to the latest stable firmware, but the problem persists. Thanks a lot in advance Br vm370

    Read the article

  • Remove a port from a VLAN (HP ProCurve)

    - by sixnumber
    I'm not too familiar with switches but I want to remove port 6 from the following 'VLAN 12' I've tried searching for an easy explanation to no avail - How do I do this please? Port Information Mode Unknown VLAN Status ---------------- -------- ------------ ---------- 5 Untagged Learn Up 6 Tagged Learn Up 8 Untagged Learn Up 18 Untagged Learn Down 22 Untagged Learn Up 26 Tagged Learn Up

    Read the article

  • Is it possible to change the voltage on a single port on an HP ProCurve 2910al POE switch and how?

    - by hjoelr
    I have a couple of HP ProCurve 2910al POE+ switches at my company that we are primarily using to power our VOIP phones that run on 48V DC. However, I have one wireless access point that I need to run off of POE, but it has to be 24V DC. I'm afraid to plug it into the POE ProCurve because I'm not sure if it will zap the device. I'm wondering if there is a way to make sure to change the voltage on a specific port to 24V instead of the (seemingly) default value of 48V. Thanks! Joel

    Read the article

  • Creating a dynamic lacp trunk from HP Procurve 2412zl to Proliant DL380 G7

    - by Maalobs
    I'm configuring an IEEE 802.3ad (LACP) dynamic trunk from a HP Procurve 2412zl (firmware version K.15.07) switch to a HP Proliant DL380 G7 server. The DL380 has 4 NICs and is running Win2008 R2, so I'm teaming the NICs together and leaving everything on the recommended "automatic" setting in the HP NIC configuration tool. The server is one of two, they'll be connected on interfaces F17-F20 and F21-F24 respectively on the switch. I need the servers in a separate VLAN, here is the configuration for the VLAN: vlan 10 name "Lab_Mgmt" untagged B2,F17-F24 ip address 172.22.71.3 255.255.255.0 tagged B21 exit There is a DHCP-relay into the VLAN 10 from another device beyond interface B21. The Advanced Traffic Management Guide says that in order to run a dynamic LACP trunk on another VLAN besides the DEFAULT_VLAN, you need to first enable GVRP and then use "forbid" to stop the interfaces from automatically joining DEFAULT_VLAN when the dynamic trunk is created. GVRP brings some other stuff with it that I don't want or need, so I disable it with "unknown-vlans disable" on all other interfaces. Here is how I do it: procurve-5412zl-1(config)# gvrp procurve-5412zl-1(config)# interface A1-A24,B1-B24,C1-C24,D1-D10,D13-D24,E1-E24, F1-F16,K1,K2 unknown-vlans disable procurve-5412zl-1(config)# vlan 1 forbid F17-F24 procurve-5412zl-1(config)# interface F17-F20 lacp active The result afterwards looks all successful: procurve-5412zl-1(config)# show trunks Load Balancing Method: L3-based (Default), L2-based if non-IP traffic Port | Name Type | Group Type ---- + -------------------------------- --------- + ------ -------- F17 | XYZTEAM3_NIC1 100/1000T | Dyn2 LACP F18 | XYZTEAM3_NIC2 100/1000T | Dyn2 LACP F19 | XYZTEAM3_NIC3 100/1000T | Dyn2 LACP F20 | XYZTEAM3_NIC4 100/1000T | Dyn2 LACP procurve-5412zl-1(config)# vlan 10 procurve-5412zl-1(vlan-10)# show lacp LACP LACP Trunk Port LACP Admin Oper Port Enabled Group Status Partner Status Key Key ---- ------- ------- ------- ------- ------- ------ ------ F17 Active Dyn2 Up Yes Success 0 0 F18 Active Dyn2 Up Yes Success 0 0 F19 Active Dyn2 Up Yes Success 0 0 F20 Active Dyn2 Up Yes Success 0 0 On the Proliant server, the NIC configuration Tool is also indicating that a 802.3ad dynamic trunk has been established. Everything should be good, but it isn't. The server is not getting an IP-address from the DHCP, which it does if I'm not enabling LACP. If I configure the server to a static IP-address on the VLAN 10 subnet, it can't even ping the switch IP-address, much less anything outside of the VLAN. The switch can't ping the server either. I did another attempt with F17-F20 tagged, and checking the box "Default Native Tag (VLAN 10)" in the NIC configuration tool on the server, but there was no difference. Does anyone have any idea what I might have missed?

    Read the article

  • Server-to-Switch Trunking in Procurve switch, what does this mean?

    - by MattUebel
    I am looking to set up switch redundancy in a new datacenter environment. IEEE 802.3ad seems to be the go-to concept on this, at least when paired with a technology that gets around the "single switch" limitation for the link aggregation. Looking through the brochure for a procurve switch I see: Server-to-Switch Distributed Trunking, which allows a server to connect to two switches with one logical trunk; increases resiliency and enables load sharing in virtualized data centers http://www.procurve.com/docs/products/brochures/5400_3500%20Product%20Brochure4AA0-4236ENW.pdf I am trying to figure out how this relates to the 802.3a standard, as it seems that it would give me what I want (one server has 2 nics, each of which is connected to separate switches, together forming a single logical nic which would provide the happy redundancy we want), but I guess I am looking for someone familiar with this concept and could add to it.

    Read the article

  • will heavy network traffic affect other connections on HP ProCurve V1810-48G?

    - by nn4l
    I have a HP ProCurve V1810-48G switch with a few servers connected to it (everything in one rack). The switch is practically in its default configuration. During copying of a few hundred GByte of data from server_a to server_b (using tar cf - data | ssh server_b 'cd myhome; tar xf -'), essentially saturating the network capacity between those two servers, I noticed network related error messages on the console of server_c - as if server_c is no longer able to send/receive traffic to server_d. After canceling the copy command everything was normal again. I would understand this if the network connection would use a shared resource, for example if server_a and server_c are in one datacenter, server_b and server_d are in another datacenter and both datacenters are connected with a 100 MBit line. But all of the mentioned servers are connected to the same switch and are located in the same IP network. I always thought that a connection between two servers on one switch will not affect any other server connected to the switch. It is also possible that the network related error messages are caused by something else - but I can't risk a network problem for any other system on this switch. Please advise.

    Read the article

  • Autonegotiate errors between HP and Cisco hardware?

    - by Satanicpuppy
    This is a bit of a specific extension to this question. I've got two ASA's that feed into a Procurve switch, and then into an IPS. All is well except that the procurve absolutely refuses to autonegotiate with the ASA's...The asa's run 100full, and the procurve autonegotiates to 100half. It does it for both ASA's, so it's probably not a failure on one of them, and everything works fine if I force the procurve to 100full. Has anyone else seen this issue? I've been buying more HP hardware, but I'm not keen on getting equipment that's not going to play nice with my Cisco backbone.

    Read the article