  • Must partprobe before using drive?

    - by Jeff Welling
    This is a followup question to Cannot mount /dev/sdc1 on Debian 5.0, special device /dev/sdc1 doesn't exist Basically, I have 6 SATA hard drives in a machine and I'm trying to create a RAID6 array with them. When I try to run the mdadm command to create (with the verbose option) a raid array, I see messages like "mdadm: super1.x cannot open /dev/sdf1: No such device or address" which are resolved by doing partprobe /dev/sdf and then re-running the mdadm command. The problem is that I have to run partprobe after each reboot, and from experience I don't think this is normal behaviour -- on no other linux machine do I have to partprobe the device before I can use it. Something must be going wrong, but how do I troubleshoot this to find out what? Could this be caused by a hardware problem? Edit: Additional note - before I seemed to only have this problem with one drive, but now I'm having it with 3 drives.

    Read the article

  • HDD vanished after wakeup from standby

    - by Sam
    In my computer I got two hard drives: One 80GB Intel X25 Postville SSD for the system and a 1,5TB Sata HDD for data. When I put the system into standby, and wake it up again, roundabout 50% of the time the 1,5TB HDD is not found. It just vanished from the system (wreaking havok to all programs running which had open files on it). Even going into the system management and refreshing the drives does not find the lost HDD. There are no messages about this in the event log. After a warm reboot the hdd is found again, just like it should. The system is a Shuttle SP35P2 Pro with 8GB Ram and DualCore CPU, OS is Windows 7 Ultimate. I even set up the OS anew, didn't help. Any ideas what might cause this? How to debug, or maybe even fix it?

    Read the article

  • Defragment an Exchange Volume

    - by IceMage
    The Scenario: I use a dedicated volume (RAID volume) to store all of my data for my Exchange 2007 server. Today, out of curiosity, I decided to check up on how fragmented the files on this data volume were. To my surprise, the answer is extremely. So, a three part question: First and Foremost, SHOULD I defragment this volume (after a full backup of course)? Be specific as to why not if I should not, or reasons I absolutely should if I should. Second, about how much time should I allow for during this maintenance period per gigabyte. The drives are all 7200 RPM SATA drives on a Hardware RAID 5 controller (Perc 5i/6i, can't remember), the files are extremely fragmented. (Over 5000 file fragments per gigabyte). Third, is there something wrong here? It seems to me like the drive shouldn't be this fragmented. Could something be configured incorrectly that could be causing this to happen?

    Read the article

  • How tot track which program causes my harddrive to spin up

    - by Andreas
    I have a strange problem: Every half hour one of my hard disks gets powered on again. I recognize this by the sound of a hard disk spinning up. So far I was not able to track which program could cause this. I ran Process Monitor to see whether there is an I/O peak coinciding with the spin-up. I checked Windows event viewer if there is an appropriate event at the same time Any ideas other than the usual disabling-services/programs etc. (which would be my next investigation step)? Also, it would be helpful to have a program that shows the current power status of all my drives, if there is one. Harddisk Sentinel unfortunately cannot do the job because it powers on all drives upon start and prevents their going into sleep mode. Thanks in advance. :)

    Read the article

  • Creating Persistent Drive Labels With UDEV Using /dev/disk/by-path

    - by Matt
    I have a new BackBlaze Pod (BackBlaze Pod 2.0). It has 45 3TB drives and they when I first set it up they were labeled /dev/sda through /dev/sdz and /dev/sdaa through /dev/sdas. I used mdadm to setup three really big 15 drive RAID6 arrays. However, since first setup a few weeks ago I had a couple of the hard drives fail on me. I've replaced them but now the arrays are complaining because they can't find the missing drives. When I list the the disks... ls -l /dev/sd* I see that /dev/sda /dev/sdf /dev/sdk /dev/sdp no longer appear and now there are 4 new ones... /dev/sdau /dev/sdav /dev/sdaw /dev/sdax I also just found that I can do this... ls -l /dev/disk/by-path/ total 0 lrwxrwxrwx 1 root root 10 Sep 19 18:08 pci-0000:02:04.0-scsi-0:0:0:0 -> ../../sdau lrwxrwxrwx 1 root root 9 Sep 19 18:08 pci-0000:02:04.0-scsi-0:1:0:0 -> ../../sdb lrwxrwxrwx 1 root root 9 Sep 19 18:08 pci-0000:02:04.0-scsi-0:2:0:0 -> ../../sdc lrwxrwxrwx 1 root root 9 Sep 19 18:08 pci-0000:02:04.0-scsi-0:3:0:0 -> ../../sdd lrwxrwxrwx 1 root root 9 Sep 19 18:08 pci-0000:02:04.0-scsi-0:4:0:0 -> ../../sde lrwxrwxrwx 1 root root 10 Sep 19 18:08 pci-0000:02:04.0-scsi-2:0:0:0 -> ../../sdae lrwxrwxrwx 1 root root 9 Sep 19 18:08 pci-0000:02:04.0-scsi-2:1:0:0 -> ../../sdg lrwxrwxrwx 1 root root 9 Sep 19 18:08 pci-0000:02:04.0-scsi-2:2:0:0 -> ../../sdh lrwxrwxrwx 1 root root 9 Sep 19 18:08 pci-0000:02:04.0-scsi-2:3:0:0 -> ../../sdi lrwxrwxrwx 1 root root 9 Sep 19 18:08 pci-0000:02:04.0-scsi-2:4:0:0 -> ../../sdj lrwxrwxrwx 1 root root 10 Sep 19 18:08 pci-0000:02:04.0-scsi-3:0:0:0 -> ../../sdav lrwxrwxrwx 1 root root 9 Sep 19 18:08 pci-0000:02:04.0-scsi-3:1:0:0 -> ../../sdl lrwxrwxrwx 1 root root 9 Sep 19 18:08 pci-0000:02:04.0-scsi-3:2:0:0 -> ../../sdm lrwxrwxrwx 1 root root 9 Sep 19 18:08 pci-0000:02:04.0-scsi-3:3:0:0 -> ../../sdn lrwxrwxrwx 1 root root 9 Sep 19 18:08 pci-0000:02:04.0-scsi-3:4:0:0 -> ../../sdo lrwxrwxrwx 1 root root 10 Sep 19 18:08 pci-0000:04:04.0-scsi-0:0:0:0 -> ../../sdax lrwxrwxrwx 1 root root 9 Sep 19 18:08 pci-0000:04:04.0-scsi-0:1:0:0 -> ../../sdq lrwxrwxrwx 1 root root 9 Sep 19 18:08 pci-0000:04:04.0-scsi-0:2:0:0 -> ../../sdr lrwxrwxrwx 1 root root 9 Sep 19 18:08 pci-0000:04:04.0-scsi-0:3:0:0 -> ../../sds lrwxrwxrwx 1 root root 9 Sep 19 18:08 pci-0000:04:04.0-scsi-0:4:0:0 -> ../../sdt lrwxrwxrwx 1 root root 9 Sep 19 18:08 pci-0000:04:04.0-scsi-2:0:0:0 -> ../../sdu lrwxrwxrwx 1 root root 9 Sep 19 18:08 pci-0000:04:04.0-scsi-2:1:0:0 -> ../../sdv lrwxrwxrwx 1 root root 9 Sep 19 18:08 pci-0000:04:04.0-scsi-2:2:0:0 -> ../../sdw lrwxrwxrwx 1 root root 9 Sep 19 18:08 pci-0000:04:04.0-scsi-2:3:0:0 -> ../../sdx lrwxrwxrwx 1 root root 9 Sep 19 18:08 pci-0000:04:04.0-scsi-2:4:0:0 -> ../../sdy lrwxrwxrwx 1 root root 9 Sep 19 18:08 pci-0000:04:04.0-scsi-3:0:0:0 -> ../../sdz I didn't list them all....you can see the problem above. They're sorted by scsi id here but sda is missing...replaced by sdau...etc... So obviously the arrays are complaining. Is it possible to get Linux to reread the drive labels in the correct order or am I screwed? My initial design with 15 drive arrays is not ideal. With 3TB drives the rebuild times were taking 3 or 4 days....maybe more. I'm scrapping the whole design and I think I am going to go with 6 x 7 RAID5 disk arrays and 3 hot spares to make the arrays a bit easier to manage and shorten the rebuild times. But I'd like to clean up the drive labels so they aren't out of order. I haven't figured out how to do this yet. Does anyone know how to get this straightened out? Thanks, Matt

    Read the article

  • Worth it to move /var to physical disk vs logical?

    - by Tammer Ibrahim
    Brief question about partition layout. I use an SSD for /, /boot, /usr, & /home partitions. I'd like to move /var to a mechanical disk to minimize writes to the SSD. I'm mainly concerned about maximizing drive life rather than maximizing performance (although I obviously wouldn't want to cripple my server). My mechanical disks consist of two drives sharing LVM, and a third used for nightly rsync backups. I also have a bunch of old 2.5in hard disks lying around. My question is, should I simply create a new LVM volume '/var' on my primary data store, or would it be worth the increased energy consumption (in terms of maximizing the lifetime of the LVMed drives) to install a low volume 2.5in disk to use just for /var? On a more general level my question is about the trade offs of placing OS mounts on the same physical volumes as my data. Thanks for any help!

    Read the article

  • What is "2LUN" mode in connection with RAID?

    - by naxa
    I've came across RAID products that also list JBOD (just a bunch of disks) mode and 2LUN mode. What the heck is 2LUN mode? I could not find a description; the closest thing seems to be LUN 'logical unit number' but I don't get the 2LUN thing. UPDATE 1 This is what Wikipedia has to say about JBOD: JBOD (derived from "just a bunch of disks"): an architecture involving multiple hard drives, while making them accessible either as independent hard drives, or as a combined (spanned) single logical volume with no actual RAID functionality. So JBOD can actually mean two different (albeit related) things. Answer of Guest says 2LUN means no spanning. Does this suggest that 2LUN would simply mean the JBOD-variant with no span?

    Read the article

  • is a mini PCIe SSD worth it?

    - by Narcolapser
    Question: Is getting a mini-PCIe worth investing in? Info: I have a an Acer Aspire 1 n270. It has this mini PCIe slot that is just sitting there empty. I would like to change this, and I would like to speed up my boot time. So I've been considering getting a mini-PCIe SSD. They are about the same price as faster same size drives of the 2.5" variation. The advantage of the mini-PCIe card is that I can have my HDD still. So I have good boot time, but still have the storage of my HDD. What I want to know is: will this allow me to spin down the HDD more often allowing me to save power? Will the OS (Ubuntu 10.04 LTS) see them as separate drives? Is there anything that the mini-PCIe slot could be better used for? Thanks. ~n

    Read the article

  • Significant OS X Finder lag when listing directories/files

    - by Jack Sleight
    I'm experiencing some significant OS X finder lag, that seems to be purely an issue with Finder itself, and not the HD or any other part of OS X (I'll explain below). The lag only appears to be when listing directories/files, where I'm seeing up to twelve or so seconds of lag (the folder opens with a blank list and the spinner going in the bottom right). This happens with both the local SSD and network drives (connected via ethernet or wifi) Browsing both local and network drives in terminal and listing directories is instant I can actually browse files on my NAS from my phone over a 3G connection from the other side of the country faster than Finder can when connected to the local network (madness!) Can anyone help? Thanks.

    Read the article

  • Cannot boot from a hard drive

    - by Martin Melka
    I have a problem booting from a hdd. I used to have it as my main drive before I bought an SSD, so I had been able to boot from it. But for some reason, now, half a year later, I can't get it to work. I completely erased it, deleting data and partitioning (using EASEUS Partition Master), then I installed Kubuntu (without changing anything in the installer), but it simply won't boot up. It always boots the drive with Windows and when I unplug this drive, it only gives me an error "PXE-E61: Media test failure, check cable", I guess it's trying to boot from LAN. I tried installing the system on a freshly deleted drive, without any other drives plugged in the pc, but the problems persist. This is how the drives look now (first one has Windows 7 installed, the second one Kubuntu): I am lost. I mean, after doing a fresh wipe and a clean install without altering anything, it should work. But it doesn't. What can be wrong here? Thanks

    Read the article

  • Inexpensive degaussers or HDD shredders?

    - by Nicholas Knight
    I do a lot of work for a small cash-strapped business that has a lot of active hard drives, most are consumer-grade SATA of about five years of age, and predictably they are dying at an increasing rate, and a lot of the time they can't even be detected, let alone complete a zero-out cycle. Right now those drives are just being stored, but that can't continue forever. We've got a couple bad LTO tapes it'd be nice to deal with, too. There are very real security and legal issues that make dropping them off with someone who claims they'll be properly destroyed a gamble. I've looked around at degaussers and HDD shredders, and the ones that don't look like they come from some guy in his basement all seem to be $3000+, which is hard to swallow right now. Is there anything out there in the $500-1500 range that you would recommend? (Speed isn't a big issue, if it takes several minutes or even hours per drive, that's completely OK, we've only got 10 or so thus far.)

    Read the article

  • Dell PowerEdge R720 - Corrupted RAID

    - by BT643
    Apologies in advance for the lengthy question. We have a Dell PowerEdge R720 server with: 2 x 136GB SAS drives in RAID 1 for the OS (Ubuntu Server 12.04) 6 x 3TB SATA drives in RAID 5 for data A few days ago we were getting errors when trying to access files on the large RAID 5 partition. We rebooted the server and got a message about the raid controller has found a foriegn config. We've had this before, and just needed to use Dell's RAID configuration utility to import foreign config on the RAID. Last time this worked, but this time, it started doing a disk check then we got this: FSCK has returned the following: "/dev/sdb1 inode 364738 has a bad extended attribute block 7 /dev/sdb1 unexpected inconsistency run fsck manually (i.e without -a or -p options) MOUNTALL fsck /ourdatapartition [1019] terminated with status 4 MOUNTALL filesystem has errors /ourdatapartition errors where found while checking the disk drive for /ourdatapartition Press F to fix errors, I to Ignore or M for Manual Recovery" We pressed F to try and fix the errors, but it eventually errored with: Inode 275841084, i_blocks is 167080, should be 0. Fix? yes Inode 275841141 has an invalid extend node (blk 2206761006, lblk 0) Clear? yes Inode 275841141, i_blocks is 227872, should be 0. Fix? yes Inode 275842303 has an invalid extend node (blk 2206760975, lblk 0) Clear? yes .... Error storing directory block information (inode=275906766, block=0, num=2699516178): Memory allocation failed /dev/sdb1: ***** FILE SYSTEM WAS MODIFIED ***** e2fsck: aborted /dev/sdb1: ***** FILE SYSTEM WAS MODIFIED ***** mountall: fsck /ourdatapartition [1286] terminated with status 9 mountall: Unrecoverable fsck error: /ourdatapartition We noticed one of the drive lights was not lit at all, and thought this may have failed and be the problem. We replaced the drive with a spare, and tried "F" to repair it again, but we keep just getting the same error as above. In the RAID configuration utility, all drives show as "online" and "optimal". We do have this data on another replicated server, so we're not worried about "recovering" anything, we just want to get the system back online asap. The server has 64 or 32GB memory, can't remember off the top of my head, but either way, with a 14TB RAID, I think it may still not be enough. Thanks EDIT - I checked the memory usage while fsck was running as suggested and after 2 or 3 minutes, it looked like this, using up nearly all of our servers memory: When it failed after 5 minutes or so with the error in my post, the memory immediately freed up again:

    Read the article

  • Will my RAID0 stay intact when I move it to a new computer?

    - by Jeremy H
    My primary drive is a 250GB WD SATA drive. So, I added 2x 500GB 7,200 RPM WD SATA drives into my Windows Vista box and created a 1TB RAID0. I then formatted the the primary drive and installed Windows 7. To my pleasant surprise when I booted into Windows 7 my RAID0 was still intact and I kept trotting along the same as I did before. Now I am replacing my motherboard, processor, and RAM and plan on formatting the primary 250GB drive again and using it to boot for a new clean install of Windows 7. My question is: if I move these two SATA drives which are setup for RAID0 into the new system, install Windows 7 again, will the RAID0 remain? Edit: Software RAID. I created it within Windows. The RAID0 does NOT contain the system boot partition.

    Read the article

  • How do I recover a RAID 1 volume on Mac OS X (10.7)?

    - by Avry
    I have a Synology NAS that I've set up with RAID 1. The device is set up with two drives, both the same size (i.e. 500 GB each), formatted in ext3, as a RAID 1 volume (i.e. even though the total capacity is 1TB, I effectively only get 500 GB). In the case of a device failure where I can only access one of the drives, how can I recover my data? The solution I'm looking for is something like: 'Put the working drive in an enclosure, and use <some software> to recover your data.'

    Read the article

  • Upgrading HP DL185 G5 8LFF, is using a Dell J1520 4-Drop SATA Adapter possible?

    - by jpreed00
    The HP DL185 G5 8LFF model supports 8 3.5" drives and 1 optical drive. However, instead of the optical drive, I'd like to have 2x 2.5" drives instead. The problem is that the PSU has no more SATA power cables (even though the motherboard has 4 additional SATA data ports). The PSU does have a free 10-pin connector and it looks like the J1520 cable from Dell would fit the bill. Link to cable description Does anyone have any experience using these cables? Are they safe? Any other ideas for adding the disks to the server if I don't use the cable? Thanks!

    Read the article

  • New harddrives failing within weeks.

    - by Jason Kealey
    I've experienced 8 hard disk failures in 3 months and have tried many things to solve the issue permanently but I have failed. I would like to know if you have any advice for me. System was running Win XP on an Asus P5W-DH Deluxe. I have setup a RAID-1 array. I started out with 2 x 500 GB 7200RPM Western Digital drives. One died. I took it out to RMA it. On the same day, the router was fried. Assumed a power surge occurred; connected an older UPS to protect the system. Once I got my hands on an identical disk, I installed it. The RAID array was rebuilt. A few days later, the other one died. Assumed the rebuild caused it to fail. Took it out for RMA. Before the other one arrived, the remaining one died. I then discovered I could re-enable them using the Intel Matrix Storage Manager. I re-enabled both and the system seemed fine for a week, until both died again. I got two new 1.5 TB 7200RPM Seagate drives and re-installed Windows 7. Also replaced the UPS and power supply. They both died again. The voltage on the plug is stable between 120 and 122V as per the UPS. None of the other devices have had any problems (monitors, etc.). At this point, I see two options: a) electrical issue in the house that was, for some reason, not blocked by the UPS. b) something else inside the system causing surges? motherboard? onboard raid controller? Failures happen fairly quickly, between 2 and 14 days after I fix the previous issue. I just gotten a new computer (Core i7) to replace it. If it is stable, I can determine that b) was the problem. If it fries its hard drive again, I can determine that it is an electrical issue in the house. Do you have any other thoughts? Any tools I can run on the drives that failed to get more information about the original SMART event history?

    Read the article

  • Windows XP 32-bit + RocketRaid 622 + 4 x 3TB = not quite a RAID setup

    - by gmoney
    I'm looking to make a 6TB RAID 10 array from my new pile of drives under Windows XP 32-bit, however they are only for auxiliary storage. After adding all the drives to an array, and initializing them XP sees only a fraction of the storage, 2TB. I'm assuming this has to do with MBR vs GPT. Is making a series of 2TB volumes and then spanning my only solution? Most questions online have to do with booting from this setup, but I'm just using them as extra storage. Hardware: 4 x 3TB Hitachi Deskstars + RocketRaid 622 + Sans Digital TR8M TowerRAID. The array is connected via eSATA.

    Read the article

  • Maximum hard drive space for an Xserve G5

    - by wjlafrance
    At my college we're upgrading an Xserve G5 (RackMac3,1) to be a file server for some courses. Currently it has one sled with a 75GB drive. Obviously, this isn't enough. I've tried some Googling on this matter and I'm hearing a ton of different stuff - custom firmware, size issues, etc. So, for anyone who knows, what's the actual lowdown on this machine. We want to put in three 2TB drives using three standard sleds, replaced with third-party drives. Is this possible?

    Read the article

  • How can one implement RAID1 with a Dell Latitude laptop containing one normal hard drive, and one hard drive in an external bay?

    - by user12583188
    OS: Win7 professional Laptop: latitude e6420 The answer to this question should address how to deploy RAID1 software wise on a dell latitude e6420. I have two Hitachi Z5K500 320GB drives (new). There is one hard drive (320GB capacity) in the system now, which contains the current installation that I would prefer to keep. The drive currently inside the laptop will be replaced with one of the Hitachi drives, and the other Hitachi drive will be fitted into the laptop by way of a Dell hard drive "caddy" enclosure, which inserts into the media bay of the laptop (you remove the cd-rom bay, insert hd-bay).

    Read the article

  • Occasional HDD Related Hangs

    - by diolemo
    I have an issue that seems to be disk related. Occasionally my system will block for 30 or so seconds and is mostly unresponsive. Those things already in memory requiring no disk access continue to function but those things requiring disk access (even small) hang. 30 seconds later everything is back to normal. I have 2 Samsung drives in RAID 0. I have 1 WD drive (has pagefile) I have an SSD used for caching (Intel Smart Response). This is a new install of Windows and the drives were fine in my old PC (~1 month ago). Has anyone experienced anything similar? Any suggestions to solve this one? Thanks in advance.

    Read the article

  • NVidia raid 5 array spooling sounds and delay

    - by Chase B. Gale
    I've had a raid 5 array setup with 3 2TB WD Green drives for about 3 years now. Starting last week, when I would access the array for the first time, I hear a loud drive spooling sound and experience a ~5 second delay before being able to access\save files. This behavior happens when I don't use the array for some time (about an hour) and after occurring it doesn't happen again if I continue to access the array. I've run SMART scans on all drives and they come back as being a-ok. What's causing this? Is my array getting close to death?

    Read the article

  • Economical way to get many harddrives into rack mount?

    - by Industrial
    Hi everyone, Please bear with me as being a bit of a newcomer at 19" rack-mounted equipment. I've thought a fair bit lately about the best way of getting 4x or 6x of 2.5" hard drives into my rack and are right now currently slightly confused about would be the best (economical) solution. After scouting the market, I've found this type of disk array units that offers built in RAID and a lot of drive slots and a truckload of geek cred, but at a price that just isn't going to fit in my budget. I've also found these type of cute adapters that takes two 2.5" drives in one 3.5" slot, but I will obviously need a chassie with a lot of 3.5" spaces in order to make it work. So what is the most economical way to house my harddrives in my rack?

    Read the article