  • How do I stop CRM from asking for admin credentials when printing report

    - by Ac0ua
    Problem: When printing a report in CRM, I am asked by the UAC for admin credentials. There is a long URL: https://(crm_hostname)/reserved.ReportViewerWebcontrol.axd?ReportSession=(ID)ControlID=(ID)Culture=1333&UICulture=1033&ReportStack=1&OpType=PrintCab Info: There are three users that have the issue laied out here. They are not admins of any kind. It looks like it is asking for permission to allow SQL Server Reporting Services 2008 to run. When I put my credentials in, it just brings up the Print dialog box (this is fine, just stop asking for credentials). I know this might sound silly but I downloaded and installed "SQL Server Reporting Services 2008" hopping my credentials would give permission right from the beginning. Giving the users local admin, I was told is not an option. Note: I did post this on community (dot) dynamics (dot) com but, they are not a very active website. Thanks for any help even if it just points me in the right direction!

    Read the article

  • How to disable System service from listening on port 80 in Windows Server 2003

    - by Miky D
    I'm trying to install a service on a Windows Server 2003 machine which is supposed to listen on port 80 but it fails to start because some other service is already listening on that port. So far I've disabled the IIS Admin service and the HTTP SSL service but no luck. When I run netstat -a -n -o | findstr 0.0:80 it gives me the process id 4 as the culprit, but when I look at the running processes that process id points to the "System" process. What can I do to get the System process to stop listening on port 80 and get my service to listen instead?

    Read the article

  • Windows 8 - Ubuntu dual boot

    - by Serkan Özkan
    I bought a new Toshiba s855 notebook with windows 8 preinstalled. Secure boot feature was enabled by default. I installed latest version of ubuntu after disabling secure boot feature(it was not possible to install ubuntu without disabling secure boot). But now when I enable secure boot, the system automatically boots into windows 8, and it boots into ubuntu when I disable secure boot. EasyBCD lists the following boot entries but I can only see Windows 8 in boot menu: Default: Windows 8 Timeout: 7 seconds EasyBCD Boot Device: C:\ Entry #1 Name: Ubuntu BCD ID: {971641cd-304a-11e2-be82-806e6f6e6963} Device: \Device\HarddiskVolume2 Bootloader Path: \EFI\ubuntu\grubx64.efi ... Entry #5 Name: Windows 8 BCD ID: {current} Drive: C:\ Bootloader Path: \windows\system32\winload.efi Any recommendations will be appreciated.

    Read the article

  • Is there a way to suppress keyboard sounds picked up by a desktop microphone in Windows 7?

    - by Dave Andersen
    The problem I'd like to solve is that my desktop microphone picks up all my keystrokes very loudly compared with my voice. Even just lightly tapping a key without depressing it causes a loud click to be picked up. I'd like a way to filter out this type of sound, while picking up voice normally. Is there any software input equalizer/filter that could do this? Or alternatively, some sort of hardware hack?

    Read the article

  • Adaptec 5805 not recognized after reboot

    - by Rakedko ShotGuns
    After rebooting the system, the controller is not recognized. It only works if the computer is shut down and turned off. I have recently updated the firmware to "Adaptec RAID 5805 Firmware Build 18948". How do I fix the problem? Configuration summary --------------------------- 1. Server name.....................raid_test Adaptec Storage Manager agent...7.31.00 (18856) Adaptec Storage Manager console.7.31.00 (18856) Number of controllers...........1 Operating system................Windows Configuration information for controller 1 ------------------------------------------------------- Type............................Controller Model...........................Adaptec 5805 Controller number...............1 Physical slot...................2 Installed memory size...........512 MB Serial number...................8C4510C6C9E Boot ROM........................5.2-0 (18948) Firmware........................5.2-0 (18948) Device driver...................5.2-0 (16119) Controller status...............Optimal Battery status..................Charging Battery temperature.............Normal Battery charge amount (%).......37 Estimated charge remaining......0 days, 16 hours, 12 minutes Background consistency check....Disabled Copy back.......................Disabled Controller temperature..........Normal (40C / 104F) Default logical drive task priority High Performance mode................Dynamic Number of logical devices.......1 Number of hot-spare drives......0 Number of ready drives..........0 Number of drive(s) assigned to MaxCache cache0 Maximum drives allowed for MaxCache cache8 MaxCache Read Cache Pool Size...0 GB NCQ status......................Enabled Stay awake status...............Disabled Internal drive spinup limit.....0 External drive spinup limit.....0 Phy 0...........................No device attached Phy 1...........................No device attached Phy 2...........................No device attached Phy 3...........................1.50 Gb/s Phy 4...........................No device attached Phy 5...........................No device attached Phy 6...........................No device attached Phy 7...........................No device attached Statistics version..............2.0 SSD Cache size..................0 Pages on fetch list.............0 Fetch list candidates...........0 Candidate replacements..........0 69319...........................31293 Logical device..................0 Logical device name............. RAID level......................Simple volume Data space......................148,916 GB Date created....................09/19/2012 Interface type..................Serial ATA State...........................Optimal Read-cache mode.................Enabled Preferred MaxCache read cache settingEnabled Actual MaxCache read cache setting Disabled Write-cache mode................Enabled (write-back) Write-cache setting.............Enabled (write-back) Partitioned.....................Yes Protected by hot spare..........No Bootable........................Yes Bad stripes.....................No Power Status....................Disabled Power State.....................Active Reduce RPM timer................Never Power off timer.................Never Verify timer....................Never Segment 0.......................Present: controller 1, connector 0, device 0, S/N 9RX3KZMT Overall host IOs................99075 Overall MB......................4411203 DRAM cache hits.................71929 SSD cache hits..................0 Uncached IOs....................29239 Overall disk failures...........0 DRAM cache full hits............71929 DRAM cache fetch / flush wait...0 DRAM cache hybrid reads.........3476 DRAM cache flushes..............-- Read hits.......................0 Write hits......................0 Valid Pages.....................0 Updates on writes...............0 Invalidations by large writes...0 Invalidations by R/W balance....0 Invalidations by replacement....0 Invalidations by other..........0 Page Fetches....................0 0...............................0 73..............................10822 8...............................3 46138...........................4916 27184...........................15226 20875...........................323 16982...........................1771 1563............................5317 1948............................2969 Serial attached SCSI ----------------------- Type............................Disk drive Vendor..........................Unknown Model...........................ST3160815AS Serial Number...................9RX3KZMT Firmware level..................3.AAD Reported channel................0 Reported SCSI device ID.........0 Interface type..................Serial ATA Size............................149,05 GB Negotiated transfer speed.......1.50 Gb/s State...........................Optimal S.M.A.R.T. error................No Write-cache mode................Write back Hardware errors.................0 Medium errors...................0 Parity errors...................0 Link failures...................0 Aborted commands................0 S.M.A.R.T. warnings.............0 Solid-state disk (non-spinning).false MaxCache cache capable..........false MaxCache cache assigned.........false NCQ status......................Enabled Phy 0...........................1.50 Gb/s Power State.....................Full rpm Supported power states..........Full rpm, Powered off 0x01............................113 0x03............................98 0x04............................99 0x05............................100 0x07............................83 0x09............................75 0x0A............................100 0x0C............................99 0xBB............................100 0xBD............................100 0xBE............................61 0xC2............................39 0xC3............................69 0xC5............................100 0xC6............................100 0xC7............................200 0xC8............................100 0xCA............................100 Aborted commands................0 Link failures...................0 Medium errors...................0 Parity errors...................0 Hardware errors.................0 SMART errors....................0 End of the configuration information for controller 1

    Read the article

  • How to add a Mac to Windows Active Directory

    - by Ben Daniel
    I've gone into the Directory Utility on the mac, clicked on the services tab, entered the Active Directory Domain and Computer ID, clicked the Bind button and it showed a little status label which flickered through 5 of 5 steps and then said "An unknown error occurred". If I ignore the error and just click the OK button further down the screen and make sure the Active Directory service is ticked in the list of services, then go to the Directory Servers tab and try to add an Active Directory by entering my ad domain, computer id, admin username and password I get an error "Unable to add the domain. An unexpected error of type -14090 (eDSAuthFailed) occurred." Any ideas?

    Read the article

  • I want to plot ocean current with a GPS in a bottle.

    - by Fantomas
    Thinking of using a wine bottle with a cork that barely sticks out. Anyhow, I want to put in a GPS, a battery and a transmitter and to be able to collect position about every minute or so. Off-the-shelf components are preferred. What are my options as far as hardware and software choices? Thank you in advance!

    Read the article

  • Vmstat indicates memory is disappearing

    - by jimbotron
    I wanted to profile the memory usage of a script. Here's the output before it was running: procs -----------memory---------- ---swap-- -----io---- -system-- ----cpu---- r b swpd free buff cache si so bi bo in cs us sy id wa 0 0 15624 186660 39460 439052 0 0 0 2 1 1 0 0 100 0 Here's the output while the script is running, at the point where free memory was at its lowest value: procs -----------memory---------- ---swap-- -----io---- -system-- ----cpu---- r b swpd free buff cache si so bi bo in cs us sy id wa 0 0 15624 11464 40312 473524 0 0 0 2 1 1 0 0 100 0 So free memory dropped by about 175 MB, and I expected that buff would increase by that amount. But it seems the other columns changed by relatively negligible amounts - how is this possible? Am I interpreting this wrong, or is some memory just not being accounted for in this output?

    Read the article

  • Getting Pango-WARNING: Invalid UTF-8 string passed to pango_layout_set_text()

    - by geerlingguy
    About three days ago, I noticed the exim mailqueue started filling up on one of my servers, and upon inspecting some of the emails using # exim -Mvb $ID, I noticed they were being sent to some system email address (which is not a real address), and the body of the messages were as follows: (process:8259): Pango-WARNING **: Invalid UTF-8 string passed to pango_layout_set_text() I'm wondering what could be causing this strange issue, as I've never heard of 'pango' at all... I've never seen that function used in my lifetime! It seems the process id (PID) is for an apache process, though, as the pids are always gone by the time I use # ps -aux to look them up. Edit: Whoops! Forgot to include the subject - looks like it's actually munin-cron that's bringing up the issue: Subject: Cron /usr/bin/munin-cron --force-root

    Read the article

  • What happened to my EEE PC keyboard?

    - by etheros
    I was using my EEE PC 1000H running Windows XP and out of the blue, the keyboard stopped working - pressing keys does absolutely nothing. It does not appear to be a hardware issue, as I am able to enter BIOS configuration with no issues. I've tried: 'Safe mode' 'Last known good configuration' Reinstalling the generic keyboard driver Removing all power sources and holding down the power button, as suggested by popular forums. What could the problem be, and what could I try?

    Read the article

  • Alternate way to create a clone of a UNIX System

    - by Spirit
    THE STORY: (If you don't like to read much, down below is the question :) ) Where I work we have two HP RP2470 servers same hardware same number of hard drives same everything :). One of them is a production server and runs HP-UX 11.00. The poor ba***rd hasn't been turned off for years and now I have to make a clone of it on the other server - just in case, for redundancy. The problem is simple (or not simple) as I have to make the the other server exactly the same. However the old version of OS (UX 11.00 is a history now) and the old software running on it, have made my task almost impossible. On the production server there is also a cloning/recover utility Ignite-UX. I tried many times to create a recovery tape with it. Then when I load the tape on the backup server, it succeeds with the loading of the tape (no errors no warnings) but on the next restart it fails to load the OS :S and drops into HP`s ISL prompt. --- THE QUESTION: Is there an alternate way to create a clone of the Unix System? The environment is: 1. 2x HP RP2470 Servers (non-Intel), same hardware, same number od HDDs (two each of them) same everything. 2. OS running: HP-UX 11.00 The production server has to be cloned without downtime - sadly :( as I hope that they will reconsider on this one For example (like on Windows platforms), if you try to copy an entire HDD with Windows inside on another HDD, and then put that HDD on another PC it will still work, as long as the hardware is the same. Can I do something like that with a Unix system? Can I somehow COPY the contents of the entire HDD, put those on another HDD, and then just load the HDD into the other server? (If you haven't read the story the servers are exactly the same) Will it work? Can it be done with ordinary commands like cp or dump or something like that? Does any one have a similar experience? --- UPDATE: 26.01.2012 NOTE: The update is related to "The Story". If you haven't read that part then you can skip this update. This is just a short update on the recover logs from the Ignite Tape.. someone with more exp. might notice something.. ... --- READING CONTENTS OF THE IGNITE TAPE --- --- OUTPUT OMITED --- ... ... x ./configure3, 413696 bytes, 808 tape blocks x ./monitor_bpr, 20480 bytes, 40 tape blocks * Download_mini-system: Complete * Loading_software: Begin * Installing boot area on disk. * Enabling swap areas. * Backing up LVM configuration for "vg00". * Processing the archive source (Recovery Archive). * Wed Jan 25 15:27:32 EST 2012: Starting archive load of the source (Recovery Archive). * Positioning the tape (/dev/rmt/0mn). * Archive extraction from tape is beginning. Please wait. * Wed Jan 25 15:39:52 EST 2012: Completed archive load of the source (Recovery Archive). * Executing user specified script: "/opt/ignite/data/scripts/os_arch_post_l". * Running in recovery mode (os_arch_post_l). * Running the ioinit command ("/sbin/ioinit -c") * Creating device files via the insf command. insf: Installing special files for sdisk instance 0 address 0/0/1/1.15.0 insf: Installing special files for sdisk instance 1 address 0/0/2/0.1.0 insf: Installing special files for sdisk instance 2 address 0/0/2/1.15.0 insf: Installing special files for stape instance 0 address 0/0/1/0.3.0 insf: Installing special files for btlan instance 0 address 0/0/0/0 insf: Installing special files for btlan instance 1 address 0/2/0/0 insf: Installing special files for pseudo driver dlpi insf: Installing special files for pseudo driver kepd insf: Installing special files for pseudo driver framebuf insf: Installing special files for pseudo driver sad * Running "/opt/upgrade/bin/tlinstall -v" and correcting transition link permissions. * Constructing the bootconf file. * Setting primary boot path to "0/0/1/1.15.0". * Executing: "/var/adm/sw/products/PHSS_20146/pfiles/iux_postload". * Executing: "/var/adm/sw/products/PHSS_25982/pfiles/iux_postload". NOTE: tlinstall is searching filesystem - please be patient NOTE: Successfully completed * Loading_software: Complete * Build_Kernel: Begin NOTE: Since the /stand/vmunix kernel is already in place, the kernel will not be re-built. Note that no mod_kernel directives will be processed. * Build_Kernel: Complete * Boot_From_Client_Disk: Begin * Rebooting machine as expected. NOTE: Rebooting system. sync'ing disks (0 buffers to flush): 0 buffers not flushed 0 buffers still dirty Closing open logical volumes... Done Console reset done. Boot device reset done. ********** VIRTUAL FRONT PANEL ********** System Boot detected ***************************************** LEDs: RUN ATTENTION FAULT REMOTE POWER FLASH OFF OFF ON ON LED State: Running non-OS code. (i.e. Boot or Diagnostics) ... ... ... --- SERVER IS PERFORMING POST SEQUENCE HERE --- --- OUTPUT OMITED --- ... ... ... ***************************************** ************ EARLY BOOT VFP ************* End of early boot detected ***************************************** Firmware Version 43.50 Duplex Console IO Dependent Code (IODC) revision 1 ------------------------------------------------------------------------------ (c) Copyright 1995-2002, Hewlett-Packard Company, All rights reserved ------------------------------------------------------------------------------ Processor Speed State CoProcessor State Cache Size Number State Inst Data --------- -------- --------------------- ----------------- ------------ 0 650 MHz Active Functional 750 KB 1.5 MB 1 650 MHz Idle Functional 750 KB 1.5 MB Central Bus Speed (in MHz) : 120 Available Memory : 2097152 KB Good Memory Required : 16140 KB Primary boot path: 0/0/1/1.15 Alternate boot path: 0/0/2/1.15 Console path: 0/0/4/1.643 Keyboard path: 0/0/4/0.0 Processor is starting autoboot process. To discontinue, press any key within 10 seconds. 10 seconds expired. Proceeding... Trying Primary Boot Path ------------------------ Booting... Boot IO Dependent Code (IODC) revision 1 HARD Booted. ISL Revision A.00.38 OCT 26, 1994 ISL booting hpux ISL>

    Read the article

  • Machine account authentication on Radius server

    - by O.Shevchenko
    My workstation is under Linux. I have an Active Directory domain controller + Radius server on Windows 2008. I can verify user account 'radius-01' using 'radtest' tool: $ radtest -t pap radius-01 password123 195.234.133.32 1812 password123 Sending Access-Request of id 98 to 195.234.73.2 port 1812 User-Name = "radius-01" User-Password = "password123" NAS-IP-Address = 127.0.1.1 NAS-Port = 1812 rad_recv: Access-Accept packet from host 195.234.133.32 port 1812, id=98, length=84 Framed-MTU = 1344 Framed-Protocol = PPP Service-Type = Framed-User Class = 0x537004f00000013700010200ac1c0... I have joined my Linux PC to Active Directory domain ARB-HRK using Samba: [root@shev-arb]# net ads testjoin Join is OK I can dump machine password: [root@shev-arb]# tdbdump /var/lib/samba/private/secrets.tdb { key(34) = "SECRETS/MACHINE_PASSWORD/ARB-HRK" data(15) = "yGgXJsquRnpT0g\00" } How can i authenticate my machine account on Radius server? Do anybody know any tools for this, like: radtest shev-arb$ yGgXJsquRnpT0g 195.234.133.32 1812 password123 (this command fails)

    Read the article

  • Is ThinkPad X61T SD card slot SDXC compatible?

    - by trismarck
    I have a Thinkpad X61T 7763 tablet and I was planning to buy a 64GB card for the SD card slot. The 64GB card supports the new SDXC standard and I'm not sure if the SD card driver / hardware can handle that. So far, I've successfully used 8GB cards in the slot, but they were SDHC ones. Thinkpad manuals don't give the answer. I wonder if anyone tried this configuration already and what was the outcome.

    Read the article

  • How can I map my server's IP address to my domain?

    - by samoz
    I rented some server space from a new host and have a static IP address and a domain name that I previously purchased, but I do not know how to register the domain name to point to my server. My previous host did this for me, but my new host only offers hardware, i.e. they won't do it for me. How can I register a domain name I own to point to my server's IP address?

    Read the article

  • memory cards capacity needs to be the same?

    - by balalakshmi
    I am not a hardware guy. I just heard this from a service engineer Memory cards of unequal capacities should not be used. that is if there is a 1 GM already in the slot, we need to add another 1 GB card only. Not 512 MB or 2 GB. Is there a problem if we use memory cards which are not equal capacities?

    Read the article

  • When Intel/AMD plan to use new CPU sockets? [closed]

    - by psihodelia
    It is very expensive always to use most modern hardware especially buying new mainboard if only a new CPU is desired. It would be much better if one knows whether and when major CPU producers plan to change CPU sockets. Do you know when it is planed to change sockets the next time? I am particularly interested in not buying Intel i7 CPU if a new CPU will be released soon with not compatible pins.

    Read the article

  • Disable USB powered light from command line?

    - by Jeff Welling
    I have a nice little USB light which has no off switch, it is 'on' for the duration of being plugged in. My question is, is there a way of disabling the USB port so as to turn off the light while it is still plugged in? Preferably, this could be done from the command line, but if it's possible at all that would be really cool regardless. I use Mac and Linux, but am interested to learn if this is possible in any OS, or if physical hardware prevents usage like this.

    Read the article

  • Dual DVI external monitors from laptop using HDMI

    - by Andy Evans
    I know there may be a few questions similar to this, but my question is regarding specific hardware configuration. I have an Asus U52f laptop with an HDMI out that I currently use to drive my 24" DVI external monitor. My question is I found an HDMI - dual DVI splitter here and was wanting to know is has anyone tried this type of configuration or would the Matrox DualHead2Go be a better solution.

    Read the article

  • Assign fixed IP address via DHCP by DNS lookup

    - by Janoszen
    Preface I'm building a virtualization environment with Ubuntu 14.04 and LXC. I don't want to write my own template since the upgrade from 12.04 to 14.04 has shown that backwards compatibility is not guaranteed. Therefore I'm deploying my virtual machines via lxc-create, using the default Ubuntu template. The DNS for the servers is provided by Amazon Route 53, so no local DNS server is needed. I also use Puppet to configure my servers, so I want to keep the manual effort on the deployment minimal. Now, the default Ubuntu template assigns IP addresses via DHCP. Therefore, I need a local DHCP server to assign IP addresses to the nodes, so I can SSH into them and get Puppet running. Since Puppet requires a proper DNS setup, assigning temporary IP addresses is not an option, the client needs to get the right hostname and IP address from the start. Question What DHCP server do I use and how do I get it to assign the IP address based only on the host-name DHCP option by performing a DNS lookup on that very host name? What I've tried I tried to make it work using the ISC DHCP server, however, the manual clearly states: Please be aware that only the dhcp-client-identifier option and the hardware address can be used to match a host declaration, or the host-identifier option parameter for DHCPv6 servers. For example, it is not possible to match a host declaration to a host-name option. This is because the host-name option cannot be guaranteed to be unique for any given client, whereas both the hardware address and dhcp-client-identifier option are at least theoretically guaranteed to be unique to a given client. I also tried to create a class that matches the hostname like this: class "my-client-name" { match if option host-name = "my-client-name"; fixed-address my-client-name.my-domain.com; } Unfortunately the fixed-address option is not allowed in class statements. I can replace it with a 1-size pool, which works as expected: subnet 10.103.0.0 netmask 255.255.0.0 { option routers 10.103.1.1; class "my-client-name" { match if option host-name = "my-client-name"; } pool { allow members of "my-client-name"; range 10.103.1.2 10.103.1.2; } } However, this would require me to administer the IP addresses in two places (Amazon Route53 and the DHCP server), which I would prefer not to do. About security Since this is only used in the bootstrapping phase on an internal network and is then replaced by a static network configuration by Puppet, this shouldn't be an issue from a security standpoint. I am, however, aware that the virtual machine bootstraps with "ubuntu:ubuntu" credentials, which I intend to fix once this is running.

    Read the article

  • Move samba and ldap config to new machine

    - by Mateusz W
    I'm not advanced administrator so this may be n00b question but I'll be grateful for help. I have following problem: I have to move my server (ubuntu server) from old machine to new. I have samba & ldap on old server, so I've copied the configuration files from the old machine to new machine, made smbldap-populate, and when I use smbldap-userlist on the new machine it lists all users from the old machine. But when I try to log in as any of these users, or show its id (id username) I get no such user error. What more I have to do to use these accounts on the new machnie?