Weblogic 10.3.4 (PS3) nodemanager wont start?
- by angelo.santagata
Hi all, well Im back from Australia and one of the things which happened was Oracle announced the PS3 release of oracles SOA & Webcenter products have been released. Now I normally use pre-installed images but I always like to install the products at least once that way I get to see its installation caveats.. Here’s one. Installation on Windows 7 64bit, 64bit JVM, generic weblogic Server installer. All worked fine, EXCEPT I cant start the node manager, I get the following error <08-Feb-2011 17:16:48> <INFO> <Loading domains file: D:\products\wls1034\WLSERV~1.3\common\NODEMA~1\nodemanager.domains> <08-Feb-2011 17:16:48> <SEVERE> <Fatal error in node manager server> weblogic.nodemanager.common.ConfigException: Native version is enabled but nodemanager native library could not be loaded at weblogic.nodemanager.server.NMServerConfig.initProcessControl(NMServerConfig.java:249) at weblogic.nodemanager.server.NMServerConfig.<init>(NMServerConfig.java:190) at weblogic.nodemanager.server.NMServer.init(NMServer.java:182) at weblogic.nodemanager.server.NMServer.<init>(NMServer.java:148) at weblogic.nodemanager.server.NMServer.main(NMServer.java:390) at weblogic.NodeManager.main(NodeManager.java:31) Caused by: java.lang.UnsatisfiedLinkError: D:\products\wls1034\wlserver_10.3\server\native\win\32\nodemanager.dll: Can't load IA 32-bit .dll on a AMD 64-bit platform at java.lang.ClassLoader$NativeLibrary.load(Native Method) at java.lang.ClassLoader.loadLibrary0(ClassLoader.java:1803) at java.lang.ClassLoader.loadLibrary(ClassLoader.java:1728) at java.lang.Runtime.loadLibrary0(Runtime.java:823) at java.lang.System.loadLibrary(System.java:1028) at weblogic.nodemanager.util.WindowsProcessControl.<init>(WindowsProcessControl.java:17) at weblogic.nodemanager.util.ProcessControlFactory.getProcessControl(ProcessControlFactory.java:24) at weblogic.nodemanager.server.NMServerConfig.initProcessControl(NMServerConfig.java:247) ... 5 more Ok it appears that the node manager has gotten confused and thinks this is a 32bit install of Weblogic Server whereas it is the 64bit install.. Might have been something I did, or didnt do, on installation (e.g. –d64 on the jvm command line), however the workaround is pretty easy. 1. Create a file called nodemanager.properties in %WL_HOME%\common\nodemanager on my machine it was D:\products\wls1034\wlserver_10.3\common\nodemanager 2. Add the following line to it NativeVersionEnabled=false 3. And start it up!, this will force it not to use .DLL files and use emulation/non native methods instead..